Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
1.
Comput Math Methods Med ; 2021: 4964195, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35003320

RESUMO

OBJECTIVE: To evaluate the efficacy of suture anchor combined with double-pulley technique for subpatellar comminuted fractures compared with wire vertical suture and Krachow in the treatment of subpatellar fractures. METHODS: Retrospectively selected 48 patients with subpatellar pole comminuted fracture admitted in our hospital from February 2013 to July 2019, 25 patients with double-pulley technique (group A), and 23 patients with vertical wire suture with Krachow suture. Patient age, gender, AT/OTA typing, injury mechanism, follow-up time, surgical time, bleeding volume, mean fracture healing time, and postoperative complications were recorded. The Insall-Salvati index immediately and 6 weeks after surgery. Bostman scores and knee activity were recorded at each follow-up, and month 12 was taken as the final result. RESULTS: Time of surgery in group A (46.52 min) was significantly shorter than in group B (76.30 min). Intraoperative bleeding in group 15.1 ml, B, group 15.9 ml. Both incisions healed in stage I, averaging clinical healing of patella fracture within 10 weeks. There was no significant difference in mean Bostman score and knee activity at month 12 (group A: 28.4, 124.8°; group B: 28.1, 125.7°). There was no significant statistical difference in the Insall-Salvati index immediately or 6 weeks between the two groups. Group B patients had two wire fractures, fracture healing and the wire removed one year after surgery, and the remaining patients had no complications such as internal fixation loosening, fracture, delayed healing, or nonhealing of fracture. CONCLUSION: Compared with the treatment of subpatellar fracture with wire vertical suture and Krachow method, suture anchor with double-pulley technique has short operation time, reliable fixation, and less complications. Patients can have early functional exercise and good knee function recovery without secondary surgery. It can be considered as an alternative therapy for this fracture and deserves clinical adoption and promotion.


Assuntos
Fraturas Ósseas/cirurgia , Fraturas Cominutivas/cirurgia , Patela/lesões , Patela/cirurgia , Âncoras de Sutura , Adulto , Fios Ortopédicos/efeitos adversos , Biologia Computacional , Feminino , Consolidação da Fratura , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/fisiopatologia , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Patela/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Estudos Retrospectivos , Âncoras de Sutura/efeitos adversos , Técnicas de Sutura/efeitos adversos
2.
J Orthop Surg Res ; 15(1): 558, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33228695

RESUMO

BACKGROUND: Several methods have been proposed to reduce plate construct stiffness and promote secondary bone healing. In this study, we explored the stiffness and strength of the new carbon fiber-reinforced poly-ether-ether-ketone (CF 50) plate compared with the titanium alloy plate (Ti6Al4V). METHODS: Titanium and CF-PEEK locking plates were tested in a tibial non-osteoporotic diaphyseal comminuted fracture model to determine construct stiffness in axial compression, torsion, and bending. Subsequently, constructs were loaded until construct failure to determine construct strength. RESULTS: Relative to the titanium locking plate, the stiffness of the CF-PEEK locking plate was 6.8% and 30.8% lower in 200 N and 700 N axial compression, respectively (P < 0.05), 64.9% lower in torsion (P < 0.05), and 48.9% lower in bending (P < 0.05). The strength of the CF-PEEK locking plate was only 2.6% lower under axial compression, 7.8% lower in torsion, and 4.8% lower in bending than the titanium locking plate (P > 0.05). CONCLUSIONS: The CF-PEEK locking plate significantly reduced axial, torsion, and bending stiffness compared with the titanium locking plate. Nonetheless, axial, torsional, and bending strength showed only a modest reduction. Considering its other advantages, which include radiolucency and artifact-free imaging, the CF-PEEK locking plate therefore deserves further clinical investigation.


Assuntos
Placas Ósseas , Fibra de Carbono , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Cetonas , Polietilenoglicóis , Fraturas da Tíbia/cirurgia , Titânio , Benzofenonas , Fenômenos Biomecânicos , Consolidação da Fratura , Fraturas Cominutivas/fisiopatologia , Humanos , Polímeros , Fraturas da Tíbia/fisiopatologia , Resultado do Tratamento
3.
J Knee Surg ; 33(1): 73-77, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30577049

RESUMO

Patellar fractures account for approximately 1% of all human body fractures. This study aimed to compare the surgical outcomes of open reduction and closed reduction for patellar fractures. This retrospective study included 62 patients (63 cases) who underwent surgical treatment of patellar fractures from 2008 to 2013. Of the 63 cases, open and closed reductions were performed in 42 and 21 cases, respectively. Plain radiography was used to assess fracture healing. Comminuted patellar fracture was the most common fracture type in both groups. Tension band wiring and cannulated screw fixation were mainly used in the open and closed reduction groups, respectively. There was no significant difference in the modified hospital for special surgery score, visual analog scale score for pain, and range of motion between the two groups. The mean union time was 3.2 and 3.0 months in open and closed reductions, respectively. Postoperative knee stiffness was noted in five cases of open reduction and in three cases of closed reduction. One patient in the open reduction group had a refracture. There were no notable differences in treatment outcomes between open and closed reductions. Thus, closed reduction may not be inferior to open reduction as a surgical treatment for patellar fractures.


Assuntos
Redução Fechada/métodos , Fraturas Ósseas/cirurgia , Fraturas Cominutivas/cirurgia , Redução Aberta/métodos , Patela/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Parafusos Ósseos , Fios Ortopédicos , Feminino , Fixação Interna de Fraturas/métodos , Consolidação da Fratura , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/fisiopatologia , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Patela/diagnóstico por imagem , Patela/lesões , Patela/fisiopatologia , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
4.
Int J Surg ; 73: 50-56, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31783165

RESUMO

BACKGROUND: Lateral locking plate (LLP) fixation has gained popularity for the treatment of proximal humeral fractures (PHFs); however, complications can occur due to loss of the medial cortical buttress from fracture comminution. MATERIALS AND METHODS: We designed a novel intramedullary anatomical medial strut with allograft bone (IAMSAB) using MIMICS software to specifically fill the intramedullary canal of the proximal humeral bone. We used finite element analysis to evaluate the biomechanical characteristics of a LLP, LLP-intramedullary fixation system (IFS), LLP-anatomical medial locking plate (AMLP), or the combined application of a LLP and IAMSAB (LLP-IAMSAB) fixation construct in patients with a PHF and an unstable medial column. RESULTS: For axial or rotational loads, under (normal) Nor or osteoporotic (Ost) bone conditions, the LLP-IAMSAB fixation construct was significantly stiffer than the LLP-IFS fixation construct, and displacement at the fracture site after LLP-IAMSAB fixation was significantly less than after LLP or LLP-IFS fixation (P < 0.05). Stiffness of the LLP-IAMSAB and LLP-AMLP fixation constructs and displacement at the fracture site after LLP-IAMSAB and LLP-AMLP fixation were not significantly different. The IFS, AMLP, and IAMSAB shared the load in the LLP and decreased the risk of implant failure. There were no significant differences in von Mises stress and stress distribution after fixation with the LLP-IFS, LLP-AMLP, and LLP-IAMSAB constructs. CONCLUSION: These data suggest that the IAMSAB can provide direct medial support or resistance to rotation and augment the biomechanics of the LLP. The combined application of the IAMSAB and LLP may achieve functional outcomes that are similar to the LLP-AMLP fixation construct.


Assuntos
Placas Ósseas , Transplante Ósseo/instrumentação , Fixação Intramedular de Fraturas/instrumentação , Instabilidade Articular/cirurgia , Fraturas do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Transplante Ósseo/métodos , Estudos de Coortes , Feminino , Análise de Elementos Finitos , Fixação Intramedular de Fraturas/métodos , Fraturas Cominutivas/fisiopatologia , Fraturas Cominutivas/cirurgia , Humanos , Instabilidade Articular/etiologia , Instabilidade Articular/fisiopatologia , Masculino , Fraturas do Ombro/complicações , Fraturas do Ombro/fisiopatologia , Articulação do Ombro/fisiopatologia , Articulação do Ombro/cirurgia
5.
J Shoulder Elbow Surg ; 28(11): 2215-2224, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31630752

RESUMO

BACKGROUND: The treatment of multifragment Mason type III fractures is challenging. Open reduction-internal fixation (ORIF), radial head arthroplasty, and in some cases, even radial head resection are the current options; however, each of these treatment methods is associated with characteristic benefits and complications. We present our experience with a radial head salvage procedure in comminuted radial head fractures irrespective of concomitant injuries, which are not accompanied by typical ORIF-related complications. METHODS: The first group comprised 29 patients with multifragment Mason type III fractures treated surgically with biological radial head spacers (group S). The fragments were reduced and fixated in an extracorporeal manner, and the reconstructed radial head was placed in its anatomic position without fixation to the shaft. The second group comprised 12 patients treated with conventional ORIF using mini-fragment plates (group P). RESULTS: Thirty patients were enrolled to undergo clinical and radiographic follow-up at an average of 76 months (range, 12-152 months). In group S, nonunion at the head-neck junction developed in 70% of the cases; however, the overall Mayo Elbow Performance Index averaged 94.8, which was superior to the average Mayo Elbow Performance Index of 83.1 in group P. Radiographic evaluation showed development of osteoarthritic changes in 75% of patients in group S and 62.5% in group P. None of the patients had wrist-joint pain. CONCLUSIONS: Preserving the native radial head in comminuted Mason type III fractures without fixation to the radial shaft is a reliable option. Excellent functional results can be expected; however, the development of osteoarthritis cannot be impeded.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Redução Aberta/métodos , Fraturas do Rádio/cirurgia , Adulto , Placas Ósseas , Estudos de Casos e Controles , Articulação do Cotovelo/fisiopatologia , Articulação do Cotovelo/cirurgia , Epífises/lesões , Epífises/cirurgia , Feminino , Seguimentos , Fixação Interna de Fraturas/instrumentação , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/etiologia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
6.
Clin Orthop Surg ; 11(3): 302-308, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31475051

RESUMO

BACKGROUND: To compare the stability of fixed- versus variable-angle locking constructs for the comminuted distal humerus fracture (AO/OTA 13-A3). METHODS: Eight pairs of complete humeri harvested from eight fresh frozen cadavers were used for the study. We fixed the intact humeri using 2.7-mm/3.5-mm locking VA-LCP stainless steel distal humerus posterolateral (nine-hole) and medial (seven-hole) plates. An oscillating saw was used to cut a 1-cm gap above the olecranon fossa. The specimens were loaded in axial mode with the rate of 1 mm per 10 seconds to failure, and stress-strain curves were compared in each pair. The mode of failure was recorded as well as the load needed for 2- and 4-mm displacement at the lateral end of the gap. RESULTS: The stiffness of the constructs, based on the slope of the stress-strain curve, did not show any difference between the fixed- versus variable-angle constructs. Likewise, there was no difference between the force needed for 2- or 4-mm displacement at the lateral gap between the fixed- and variable-angle constructs. The mode of failure was bending of both plates in all specimens and screw pull-out in four specimen pairs in addition to the plate bending. CONCLUSIONS: Our results did not show any difference in the biomechanical stability of the fixed- versus variable-angle constructs. There was not any screw breakage or failure of the plate-screw interface.


Assuntos
Parafusos Ósseos/efeitos adversos , Articulação do Cotovelo/cirurgia , Fraturas Cominutivas/fisiopatologia , Fraturas Cominutivas/cirurgia , Fraturas do Úmero/fisiopatologia , Fraturas do Úmero/cirurgia , Idoso , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Análise de Falha de Equipamento , Fixação Interna de Fraturas/instrumentação , Humanos , Masculino , Estresse Mecânico , Lesões no Cotovelo
7.
Injury ; 50(11): 1790-1794, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31324342

RESUMO

INTRODUCTION: This study aims to identify patient and intra-operative factors that contribute to non-union in locked lateral plating for distal femoral fractures. METHODS: Systematic searches of English-language articles in Ovid Medline, PubMed, Embase, Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews were undertaken in February 2018 according to the PRISMA guidelines. The search terms were (fracture or fracture*) AND (distal femur or distal femoral) AND (malunion or non-union). Eligible studies published at any time reported non-union rates and compared patient and intraoperative factors in patients who underwent locked lateral plating for traumatic distal femoral fractures. The quality of included papers was assessed using The Journal of Bone and Joint Surgery levels of evidence (Wright et al., 2003), and further appraised using the Downs and Black score (Downs and Black, 1998). RESULTS: Eight studies investigating 1380 distal femoral fractures were found to satisfy the inclusion and exclusion criteria. These studies analysed a variety of patient and intra-operative factors that may contribute to non-union. These include high BMI, open fracture, comminution, fracture infection, stainless steel plate material, shorter working length, open reduction and internal fixation when compared with minimally invasive plate osteosynthesis, high construct rigidity scores and purely locking screw constructs. CONCLUSION: This review has identified multiple factors which potentially contribute to non-union including stainless steel plate material, high construct rigidity scores and purely locking screw constructs. These findings may reflect that overly rigid plating constructs can contribute to non-union. However, they should be taken in the context of heterogeneity amongst included studies, with further research necessary to support these findings.


Assuntos
Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas , Fraturas não Consolidadas/etiologia , Índice de Massa Corporal , Placas Ósseas , Fraturas do Fêmur/fisiopatologia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Consolidação da Fratura/fisiologia , Fraturas Cominutivas/complicações , Fraturas Cominutivas/fisiopatologia , Fraturas Expostas/complicações , Fraturas Expostas/fisiopatologia , Fraturas não Consolidadas/fisiopatologia , Humanos , Osteomielite/complicações , Osteomielite/fisiopatologia , Falha de Prótese
8.
J Foot Ankle Surg ; 58(5): 916-919, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31345755

RESUMO

The purpose of this cadaveric study was to compare the biomechanical properties of dual nonlocked plating and single-locked plating using matched pairs of isolated fibula specimens. Fractures were simulated in 10 matched pairs of isolated cadaveric fibulae and plated with a single lateral locking plate for right-sided specimens, or with a one-third tubular plate and a 7-hole 2.4-mm minifragment adaption plate for left-sided specimens. An external rotation torque was applied at a rate of 1°/second, and torque at 10° was measured. Each fibula specimen was evaluated using a micro computed tomography scanner, and bone mineral density was calculated as milligrams of bone per cubic centimeter of volume. Dual nonlocked plating and locked plating specimens demonstrated torque measurements that were not significantly different at 10° of external rotation (1.48 N·m and 1.92 N·m, respectively; p = .093). The stiffness of the dual nonlocked plated and locked plating constructs were not significantly different (p = .228 and p = .543, respectively). The effect of bone mineral density on maximum torque at failure was not a reliable predictor of maximum torque in either the dual nonlocked plating or locked plating specimens (R2 = 0.548 and R2 = 0.096, respectively). We found no differences in torque at 10° of external rotation or stiffness between locking plate and dual nonlocking plate fixation constructs. This study provides evidence that dual nonlocked plating likely constitutes adequate fixation in situations in which a locking plate is being considered for comminuted distal fibula fractures.


Assuntos
Placas Ósseas , Fíbula/lesões , Fixação Interna de Fraturas/instrumentação , Fraturas Cominutivas/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Fraturas Cominutivas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Suporte de Carga
9.
Bull Hosp Jt Dis (2013) ; 77(1): 33-38, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30865862

RESUMO

The Essex-Lopresti injury is caused by a high energy mechanism and consists of a characteristic triad: a comminuted radial head fracture, disruption of the distal radioulnar joint, and tearing of the interosseous membrane. These injuries are often difficult to diagnosis on initial evaluation, and the majority are missed acutely. Chronic Essex-Lopresti injuries lead to radioulnar longitudinal instability, proximal radius migration, ulnocarpal impaction, and chronic elbow pain. These injuries present a challenging problem for the treating surgeon.


Assuntos
Lesões no Cotovelo , Fraturas Cominutivas/complicações , Instabilidade Articular/complicações , Fraturas do Rádio/complicações , Traumatismos do Punho/complicações , Articulação do Punho , Fenômenos Biomecânicos , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/fisiopatologia , Articulação do Cotovelo/cirurgia , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/fisiopatologia , Fraturas Cominutivas/terapia , Humanos , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Procedimentos Ortopédicos , Valor Preditivo dos Testes , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/fisiopatologia , Fraturas do Rádio/terapia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Resultado do Tratamento , Traumatismos do Punho/diagnóstico por imagem , Traumatismos do Punho/fisiopatologia , Traumatismos do Punho/cirurgia , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/fisiopatologia , Articulação do Punho/cirurgia
10.
J Orthop Trauma ; 33(7): e263-e269, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30844960

RESUMO

OBJECTIVES: To determine whether uncemented implants would provide similar outcomes while avoiding the complications associated with cement in the treatment of elderly patients with proximal humerus fractures (PHFs) with primary reverse total shoulder arthroplasty (RTSA). DESIGN: Case series. SETTING: A single Level I trauma center. PATIENTS/PARTICIPANTS: A prospectively obtained cohort of 30 patients who underwent uncemented RTSA as initial treatment for a comminuted PHF: 4 male, 26 female; average age 71 ± 11 years. INTERVENTION: Uncemented RTSA. MAIN OUTCOME MEASURES: (1) Radiographic analysis, (2) postoperative clinical range of motion, and (3) functional outcome scores: the American Shoulder and Elbow Surgeons Shoulder score and the Simple Shoulder Test score. RESULTS: Radiographic analysis showed 97% achieved stable humeral stem fixation and 70% had healing of the tuberosities in anatomical position. Average range of motion was 130 ± 31 degrees of forward flexion, 32 ± 18 degrees of external rotation, and internal rotation to the midlumbar spine. Average American Shoulder and Elbow Surgeons Shoulder score was 82.0 ± 13.5 (with an average pain rating of 0.8 ± 1.3), and average Simple Shoulder Test score was 69.4% ± 19.1%. CONCLUSIONS: Our data show that treatment of comminuted PHFs in elderly patients with uncemented RTSA can consistently produce good clinical outcomes with a low rate of complications and suggest that cement may not be necessary for RTSA in the trauma setting. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Ombro/métodos , Fraturas Cominutivas/cirurgia , Amplitude de Movimento Articular/fisiologia , Fraturas do Ombro/cirurgia , Articulação do Ombro/cirurgia , Idoso , Cimentos Ósseos , Feminino , Seguimentos , Fraturas Cominutivas/diagnóstico , Fraturas Cominutivas/fisiopatologia , Humanos , Masculino , Estudos Prospectivos , Radiografia , Reoperação , Fraturas do Ombro/diagnóstico , Fraturas do Ombro/fisiopatologia , Articulação do Ombro/fisiopatologia
11.
J Orthop Surg (Hong Kong) ; 27(1): 2309499018825223, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30798735

RESUMO

BACKGROUND: The goal of this study was to evaluate the clinical effect of Regan-Morrey type II comminuted coronoid process fracture treated with mini plate through the direct anterior approach (DAA). METHODS: Ten patients who underwent open reduction and internal fixation (ORIF) with mini plate through the DAA between February 2013 and August 2016 was included. There were three women and seven men, with an average age of 34.4 ± 7.5 years. At the final follow-up, the Mayo Elbow Performance Index (MEPS), Visual Analogue Scale (VAS) score, Disability of the Arm, Shoulder, and Hand (DASH) score, and the elbow range of motion were noted. RESULTS: The mean follow-up was 26.3 ± 2.2 (range 24-31) months. The mean elbow arc of motion was 118.5° with a mean arc of extension of 4° ± 5.2° and flexion of 122.5° ± 7.2°.The mean forearm pronation was 72° ± 7.2°, and the mean supination was 68° ± 6.3° with a mean forearm rotation arc of 140°. The average postoperative score according to the MEPS was 91 ± 5.7 points (range 80-100 points), and all patients achieved satisfactory scores (8 excellent and 2 good). The final average VAS score was 0.6 ± 1 (range 0-3). The final average DASH score was 4.0 ± 1.6 (range 2.3-7.4). None of the patients complained about elbow instability that required secondary surgery. No complications of infection, joint incongruency, fracture nonunion, median nerve palsy, or implant failure were reported. CONCLUSIONS: ORIF with mini plate through the DAA for the treatment of the type II comminuted coronoid process fractures can achieve satisfactory outcomes.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Fraturas da Ulna/cirurgia , Adulto , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/fisiopatologia , Articulação do Cotovelo/cirurgia , Feminino , Fraturas Cominutivas/diagnóstico , Fraturas Cominutivas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Amplitude de Movimento Articular , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Fraturas da Ulna/diagnóstico , Fraturas da Ulna/fisiopatologia , Adulto Jovem
12.
J Invest Surg ; 32(6): 566-570, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29308925

RESUMO

Purpose: To determine the efficacy of modified titanium tension band plus patellar tendon tunnel steel 8 "reduction band" versus titanium cable tension band fixation for the treatment of patellar lower pole fracture. Materials and Methods: 58 patients with lower patella fracture were enrolled in this study, including 30 patients treated with modified titanium cable tension band plus patellar tibial tunnel wire "8" tension band internal fixation (modified group), and 28 patients with titanium cable tension band fixation. All patients were followed up for 9∼15 months with an average of 11.6 months. Results: Knee flexion was significantly improved in the modified group than in the titanium cable tension band group (111.33 ± 13 degrees versus 98.21 ± 21.70 degrees, P = 0.004). The fracture healing time showed no significant difference. At the end of the follow-up, the improvement excellent rate was 93.33% in the modified group, and 82.14% in the titanium cable tension band group. Titanium cable tension band internal fixation loosening was found in 2 cases, including 1 case of treatment by two surgeries without loose internal fixation. Conclusions: The modified titanium cable tension band with "8" tension band fixation showed better efficacy for lower patella fractures than titanium cable tension band fixation.


Assuntos
Fixação Interna de Fraturas/instrumentação , Fraturas Cominutivas/cirurgia , Articulação do Joelho/cirurgia , Patela/lesões , Adulto , Idoso , Parafusos Ósseos , Fios Ortopédicos , Feminino , Seguimentos , Consolidação da Fratura/fisiologia , Fraturas Cominutivas/fisiopatologia , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Patela/cirurgia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Estudos Retrospectivos , Aço , Titânio , Resultado do Tratamento
13.
Injury ; 50(2): 409-414, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30391068

RESUMO

BACKGROUND: The main purpose of this study is to introduce our surgical technique and report surgical outcomes for percutaneous cable fixation in the treatment of subtrochanteric femoral fractures. METHODS: Between May 2013 and April 2017, 51 patients with subtrochanteric femoral fractures treated with closed intramedullary nailing and percutaneous cable fixation were enrolled in this study. Postoperative angulation, union rate, time from injury to union, and femoral shortening were also evaluated to assess radiologic outcomes. Clinical outcomes, including range of hip flexion, walking ability, and Harris hip score at the last follow-up were evaluated. RESULTS: Average coronal and sagittal angulation after surgery were 0.9 (range 0-5) and 0.3 (range 0-5), respectively. There was no postoperative angulation of more than 5°. Average shortening of the femur at 1-year follow-up was 2.7 mm (range 0-15). Bone union was achieved in 50 patients (98.0%) and average time to union was 18.6 weeks (range 12-48). Hip flexion, walking ability and Harris hip score at the last follow up were 115.6° (90-120), 7.9 (5-9), and 88.3 (65-100), respectively. CONCLUSION: Percutaneous cerclage cable fixation can provide a greater likelihood of achieving anatomical reduction and increased stability of fracture, while preserving biology around the fracture site. Thus, percutaneous cerclage cable fixation can be an effective surgical technique for the treatment of complex subtrochanteric fractures.


Assuntos
Fios Ortopédicos , Fixação Intramedular de Fraturas , Consolidação da Fratura/fisiologia , Fraturas Cominutivas/cirurgia , Fraturas do Quadril/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Pinos Ortopédicos , Feminino , Fixação Intramedular de Fraturas/instrumentação , Fraturas Cominutivas/fisiopatologia , Guias como Assunto , Fraturas do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
14.
Eur J Trauma Emerg Surg ; 45(2): 213-219, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30386865

RESUMO

PURPOSE: There have been no prior case series of isolated iliac wing fracture (IIWF) due to low-energy trauma in geriatric patients in the literature. The aim of this study was to describe the characteristics of IIWF in geriatric patients, and to present a case series of IIWF in geriatric patients who underwent our minimally invasive screw fixation technique named 'iliac pillar screw fixation'. MATERIALS AND METHODS: We retrospectively reviewed six geriatric patients over 65  years old who had isolated iliac wing fracture treated with minimally invasive screw fixation technique between January 2006 and April 2016. RESULTS: Six geriatric patients received iliac pillar screw fixation for acute IIWFs. The incidence of IIWFs was approximately 3.5% of geriatric patients with any pelvic bone fractures. The main fracture line exists in common; it extends from a point between the anterosuperior iliac spine and the anteroinferior iliac spine to a point located at the dorsal 1/3 of the iliac crest whether fracture was comminuted or not. Regarding the Koval walking ability, patients who underwent iliac pillar screw fixation technique tended to regain their pre-injury walking including one patient in a previously bedridden state. The visual analog scale score for pain at the last follow-up was quite satisfactory. Union was achieved in all patients at the last follow-up. CONCLUSIONS: Geriatric patients can have a form of IIWF caused by low-energy trauma that is a type of fragility fracture of the pelvis. Because subsequent deterioration of their walking status followed by a long period of non-weight bearing in geriatric patients could be as threatening as the fracture itself, the treatment paradigm for IIWF due to low-energy trauma in geriatric patients should differ from that due to high-energy trauma in most patients. In these types of fractures, minimally invasive surgical management that includes iliac pillar screw fixation can lead to good outcomes.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Fraturas Cominutivas/cirurgia , Ílio/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos , Ossos Pélvicos/cirurgia , Idoso , Parafusos Ósseos , Feminino , Consolidação da Fratura/fisiologia , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/fisiopatologia , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/fisiopatologia , Humanos , Ílio/lesões , Masculino , Ossos Pélvicos/lesões , Complicações Pós-Operatórias , Estudos Retrospectivos , Resultado do Tratamento , Suporte de Carga/fisiologia
15.
Injury ; 49(6): 1203-1207, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29609972

RESUMO

INTRODUCTION: Comminuted patella fractures are uncommon and difficult fractures to manage. Multiple treatment modalities have been suggested, with little clinical data to support practice. Recent biomechanical and technical investigations have described successful plate fixation of comminuted patella fractures. The purpose of this study was to evaluate radiographic, clinical and functional outcome of comminuted patella fractures treated with a fixed angle locking plates. We believe stable fixation, which results in successful fracture union and functional recovery, can be achieved with this technique. MATERIALS AND METHODS: A retrospective review was performed at a single regional academic Level 1 trauma hospital. All comminuted patella fractures treated with a fixed angle locking plate (AO/OTA 34C2 and C3) over a six-year period were evaluated. Thirty-six patients were identified. Average length of follow up was 154 weeks (range 12-297 weeks). Twenty patients were available for functional outcome scoring. Primary outcome measures were: Knee Outcome Score (KOS), Lower Extremity Functional Scale (LES) and goniometer measured knee range of motion. Secondary outcomes evaluated the need for additional screw or cerclage fixation, reoperation for any reason, bothersome hardware, infection and nonunion. RESULTS: Average KOS = 57.2 (20-74), average LES = 58.9 (15-80). Median extension = 0° (full extension), median flexion = 130°. Supplemental screws were used in 17/36 cases; cerclage used in 2/36 cases. Hardware irritation was noted in 4/20 patients, no patient requested elective hardware removal, one patient had failure of fixation and no nonunions were identified. CONCLUSION: Fixed angle plate stabilization of comminuted patella fractures is a viable technique for fracture fixation. Good to excellent return of knee function and low complication rates, including need for hardware removal, can be expected.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/métodos , Consolidação da Fratura/fisiologia , Fraturas Cominutivas/cirurgia , Traumatismos do Joelho/cirurgia , Articulação do Joelho/fisiopatologia , Patela/lesões , Adulto , Idoso , Idoso de 80 Anos ou mais , Parafusos Ósseos , Feminino , Fixação Interna de Fraturas/instrumentação , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/fisiopatologia , Humanos , Traumatismos do Joelho/diagnóstico por imagem , Traumatismos do Joelho/fisiopatologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Patela/diagnóstico por imagem , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
16.
Orthop Traumatol Surg Res ; 104(2): 245-249, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29408687

RESUMO

INTRODUCTION: Cuboid fractures are very rare. Hence, their treatment has not been standardized. Advances in imaging techniques, particularly three-dimensional computed tomography (3D CT), and the introduction of cuboid-specific plates has improved the care of these injuries. The aim of this study was to determine the radiological and clinical outcomes of anatomical reconstruction of comminuted cuboid fractures with a locking plate. HYPOTHESIS: Fixation of comminuted cuboid fractures with a cuboid-specific locking plate leads to stable anatomical reduction and good functional outcomes. MATERIAL AND METHODS: This was a retrospective study of 9 consecutive cases of comminuted cuboid fracture treated at a single hospital between January 2009 and December 2015. A 3D CT scan was performed preoperatively with subtraction of the posterior tarsal bone to allow the articular facets to be viewed and analyzed. Fracture fixation was done with a Locking Cuboid Plate (DePuy Synthes™). Associated lesions in the foot were treated during the same procedure. The patients were reviewed by an independent observer who performed a clinical examination, and determined the AOFAS and Maryland Foot Score. The success of the reconstruction was determined by comparing the parameters on weight-bearing X-rays views between the fixed and non-operated cuboid. RESULTS: The mean follow-up was 4.1 years (range 1-6). The Maryland Foot Score was 93.1 [86-100] and the AOFAS was 91.9 [82-100]. The reconstruction was anatomical and long lasting in all 9 cases. There was no foot misalignment in the frontal plane, based on the radiographs (hindfoot axis 5.5° [0-9]). The mean Djian-Annonier angle was 123.9° [108-130]. CONCLUSION: Cuboid fractures can be treated effectively through appropriate imaging and with a cuboid-specific locking plate as evidenced by very good midterm clinical and radiological outcomes in this study. LEVEL OF EVIDENCE: IV Retrospective study.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fraturas Cominutivas/cirurgia , Ossos do Tarso/cirurgia , Adulto , Idoso de 80 Anos ou mais , Placas Ósseas , Feminino , Seguimentos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/fisiopatologia , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/fisiopatologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos , Ossos do Tarso/lesões , Tomografia Computadorizada por Raios X
17.
Foot Ankle Surg ; 24(4): 326-329, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29409241

RESUMO

BACKGROUND: Open reduction and internal fixation is the current standard of treatment of displaced distal fibula fractures, whereupon using a lag screw often is impossible because of a multifragmantary fracturezone. This study investigates in what extend polyaxial-locking plating is superior to non-locking constructs in unstable distal fibula fractures. METHODS: Seven pairs of human cadaver fibulae were double osteotomized in standardized fashion with a 5mm gap. This gap simulated an area of comminution, where both main fragments were no longer in direct contact. One fibula of the pair was managed using a 3.5-mm screw in a polyaxial-locking construct and the other fibula in a non-locking construct.


Assuntos
Fraturas do Tornozelo/cirurgia , Placas Ósseas , Fíbula/cirurgia , Fixação Interna de Fraturas/instrumentação , Fraturas Cominutivas/cirurgia , Fraturas do Tornozelo/fisiopatologia , Fenômenos Biomecânicos , Parafusos Ósseos , Cadáver , Feminino , Fíbula/lesões , Fíbula/fisiopatologia , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/fisiopatologia , Humanos , Masculino , Modelos Anatômicos
18.
J Shoulder Elbow Surg ; 27(2): e38-e44, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29128376

RESUMO

BACKGROUND: We report the long-term results of a cohort of patients after radial head replacement with a bipolar design and a smooth cementless stem at a mean follow-up of 10.4 years. METHODS: Of 17 possible patients from a previous minimum 2-year follow-up study, 16 were available for review. Patients were assessed using clinical and radiographic examination and with standardized outcome measures. Range of motion, stability, and radiographic evaluation of implant loosening and joint degeneration were assessed. Comparisons were performed using the Wilcoxon signed rank test for unequal groups. RESULTS: The average follow-up was 10.5 years (range, 8.5-12 years). The median visual analog scale was 1 (range, 0-5), Minnesota Elbow Performance Index was 93 (range, 70-100), and the Disabilities of the Arm, Shoulder and Hand was 7.5 (range, 0-53). Range of motion was decreased on the operative side compared with the nonoperative side for flexion/extension (P = .005) and pronation/supination (P = .015). Grip strength was decreased on the affected side (P = .045). No patients had elbow instability. Significant arthritic changes developed in 2 patients at the ulnohumeral joint. The median cantilever quotient was 0.4 (range, 0.30-0.50). Osteolysis in zones 1 to 7 was found in all but 2 patients. The median stem radiolucency was 0.5 mm (range, 0.2-0.9 mm). No reoperations occurred since our previous report. Implant survival in this cohort was 97%. CONCLUSION: Bipolar radial head prosthesis with a smooth cementless stem effectively restores elbow stability and function after comminuted radial head fractures with or without concomitant elbow instability. Our study demonstrates excellent long-term implant survival.


Assuntos
Artroplastia de Substituição do Cotovelo/métodos , Articulação do Cotovelo/cirurgia , Prótese de Cotovelo , Previsões , Fraturas Cominutivas/cirurgia , Fraturas do Rádio/cirurgia , Rádio (Anatomia)/cirurgia , Adulto , Idoso , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/fisiopatologia , Feminino , Seguimentos , Fraturas Cominutivas/diagnóstico , Fraturas Cominutivas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Rádio (Anatomia)/diagnóstico por imagem , Fraturas do Rádio/diagnóstico , Fraturas do Rádio/fisiopatologia , Amplitude de Movimento Articular , Resultado do Tratamento
19.
J Shoulder Elbow Surg ; 26(12): 2200-2205, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29037534

RESUMO

BACKGROUND: The aim of this study was to compare the fixation rigidity of anterior, anterosuperior, and superior plates in the treatment of comminuted midshaft clavicle fractures. METHODS: Six-hole titanium alloy plates were produced according to anatomic features of fourth-generation artificial clavicle models for anterior (group I; n = 14), anterosuperior (group II; n = 14), and superior (group III; n = 14) fixation. After plate fixation, 5-mm segments were resected from the middle third of each clavicle to create comminuted fracture models. Half the models from each group were tested under rotational forces; the other half were tested under 3-point bending forces. Failure modes, stiffness values, and failure loads were recorded. RESULTS: All models fractured at the level of the distalmost screw during the failure torque, whereas several failure modes were observed in 3-point bending tests. The mean stiffness values of groups I to III were 636 ± 78, 767 ± 72, and 745 ± 214 N ∙ mm/deg (P = .171), respectively, for the torsional tests and 38 ± 5, 20 ± 3, and 13 ± 2 N/mm, respectively, for the bending tests (P < .001 for group I vs. groups II and III; P = .015 for group II vs. group III). The mean failure torque values of groups I to III were 8248 ± 2325, 12,638 ± 1749, and 10,643 ± 1838 N ∙ mm (P = .02 for group I vs. II), respectively, and the mean failure loads were 409 ± 81, 360 ± 122, and 271 ± 87 N, respectively (P = .108). CONCLUSIONS: In the surgical treatment of comminuted midshaft clavicle fractures, the fixation strength of anterosuperior plating was greater than that of anterior plating under rotational forces and similar to that of superior plating.


Assuntos
Placas Ósseas , Clavícula/lesões , Clavícula/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Fenômenos Biomecânicos , Parafusos Ósseos , Clavícula/fisiopatologia , Diáfises/lesões , Diáfises/cirurgia , Fraturas Cominutivas/fisiopatologia , Humanos , Modelos Anatômicos , Maleabilidade , Rotação , Torque
20.
Injury ; 48(10): 2248-2252, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28712488

RESUMO

INTRODUCTION: Two-stage limb reconstruction is an option for patients with critical size segmental bone defects following acute trauma or non-union. Reconstruction is technically demanding and associated with a high complication rate. Current protocols for limb reconstruction have well-documented challenges, and no study has reported on patient outcomes using a validated questionnaire. In this study, we aimed to examine the clinical and patient-centered outcomes following our surgical protocol for two-stage limb reconstruction following critical size segmental defects. PATIENTS AND METHODS: A single surgeon performed reconstruction of long bone defects using antibiotic impregnated cement spacers and intramedullary cancellous bone autograft. A retrospective chart review was performed. Three reviewers independently measured time to union based on radiographs. The Lower Extremity Functional Scale (LEFS) survey was administered to patients after most recent follow-up. RESULTS: Ten limbs representing nine patients were included. All patients sustained a lower extremity injury, and one patient had bilateral lower extremity injuries. Average clinical follow-up was 18.3 months (range 7-33) from final surgical intervention, and follow-up to questionnaire administration was 28 months (range 24-37). The mean time between stages was 3.1 months. Average time to unrestricted weight-bearing was 7.9 months from Stage 1 (range 3.4-15.9) and 4.5 months from Stage 2 (range 1.1-11.6). Average time to full union was 16.7 months from Stage 1 (range 6.4-28.6) and 13.5 months from Stage 2 (range 1.8-27). Eight patients (nine limbs) participated in the LEFS survey, the average score was 53.1 (range 30-67), equating to 66% of full functionality (range 38%-84%). Complications included 5 infections, 3 non-unions, and one amputation. There was a moderate positive correlation between infection at any time point and non-union (R=0.65, p=0.03). DISCUSSION AND CONCLUSIONS: Outcomes in this small patient cohort were good despite risks of complication. There is an association between infection and non-union. Further studies addressing clinical and functional outcomes will help to guide expectations for future surgeons and patients.


Assuntos
Transplante Ósseo , Diáfises/cirurgia , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas , Fraturas Cominutivas/cirurgia , Fraturas não Consolidadas/cirurgia , Infecção da Ferida Cirúrgica/terapia , Fraturas da Tíbia/cirurgia , Adulto , Antibacterianos , Cimentos Ósseos , Protocolos Clínicos , Terapia Combinada , Diáfises/patologia , Feminino , Fraturas do Fêmur/complicações , Fraturas do Fêmur/fisiopatologia , Seguimentos , Consolidação da Fratura , Fraturas Cominutivas/complicações , Fraturas Cominutivas/fisiopatologia , Fraturas não Consolidadas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Reoperação , Estudos Retrospectivos , Fraturas da Tíbia/complicações , Fraturas da Tíbia/fisiopatologia , Adulto Jovem