Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.810
Filtrar
1.
J Plast Surg Hand Surg ; 59: 46-52, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747532

RESUMO

Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results. Five female patients aged 63-74 with dorsally angulated extra-articular malunions underwent surgery using 3D-printed guides and the shim instrument. The plate position, drilling guide alignment, screw placements, and distal radius correction on postoperative CTs were compared with the surgical plans. Errors were measured using an anatomical coordinate system, and standard 2D radiographic measures were extracted. Preoperative dorsal tilt ranged from 16° to 35°, and postoperative volar tilt from 1° to 11°. 3D analysis revealed mean absolute correction errors of 6.1° in volar tilt, 1.6° in radial inclination, and 0.6 mm in ulnar variance. The volar tilt error due to the shim instrument, indicated by the mean angle error of the distal screws to the plate, was 2.1° but varied across the five patients. Settling of the distal radius, due to tension during and after reduction, further contributed to a mean loss of 3.5° in volar tilt. The shim instrument helped with securing plates at the intended angle; however, further correction improvements should consider the tension between the fragments of osteoporotic bone.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas Mal-Unidas , Osteotomia , Fraturas do Rádio , Humanos , Feminino , Osteotomia/métodos , Osteotomia/instrumentação , Pessoa de Meia-Idade , Fraturas do Rádio/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Idoso , Fraturas Mal-Unidas/cirurgia , Fraturas Mal-Unidas/diagnóstico por imagem , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Impressão Tridimensional , Cirurgia Assistida por Computador , Imageamento Tridimensional , Parafusos Ósseos , Tomografia Computadorizada por Raios X
2.
Arch Orthop Trauma Surg ; 144(5): 2461-2467, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38578309

RESUMO

Distal radius fractures rank among the most prevalent fractures in humans, necessitating accurate radiological imaging and interpretation for optimal diagnosis and treatment. In addition to human radiologists, artificial intelligence systems are increasingly employed for radiological assessments. Since 2023, ChatGPT 4 has offered image analysis capabilities, which can also be used for the analysis of wrist radiographs. This study evaluates the diagnostic power of ChatGPT 4 in identifying distal radius fractures, comparing it with a board-certified radiologist, a hand surgery resident, a medical student, and the well-established AI Gleamer BoneView™. Results demonstrate ChatGPT 4's good diagnostic accuracy (sensitivity 0.88, specificity 0.98, diagnostic power (AUC) 0.93), surpassing the medical student (sensitivity 0.98, specificity 0.72, diagnostic power (AUC) 0.85; p = 0.04) significantly. Nevertheless, the diagnostic power of ChatGPT 4 lags behind the hand surgery resident (sensitivity 0.99, specificity 0.98, diagnostic power (AUC) 0.985; p = 0.014) and Gleamer BoneView™(sensitivity 1.00, specificity 0.98, diagnostic power (AUC) 0.99; p = 0.006). This study highlights the utility and potential applications of artificial intelligence in modern medicine, emphasizing ChatGPT 4 as a valuable tool for enhancing diagnostic capabilities in the field of medical imaging.


Assuntos
Fraturas do Rádio , Humanos , Fraturas do Rádio/diagnóstico por imagem , Radiografia/métodos , Inteligência Artificial , Sensibilidade e Especificidade , Feminino , Masculino , Pessoa de Meia-Idade , Traumatismos do Punho/diagnóstico por imagem , Idoso , Adulto , Fraturas do Punho
3.
BMC Musculoskelet Disord ; 25(1): 320, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654260

RESUMO

BACKGROUND: The precise influence of plate position on clinical outcomes in the context of volar fixed-angle plating for distal radius fractures is not fully understood. This article aims to investigate the influence of plate position on clinical results, and functional outcomes in patients treated with volar fixed plating for distal radius fractures. METHODS: A total of 58 patients with 64 distal radius fractures were included in the study. Patient demographics, fracture characteristics, surgical details, and radiographic data were collected. Post-operative AP and Lat views of all patients taken on the first day after surgery were evaluated. Volar Tilt, Radial Inclination and Radial Height measurements were used as reduction criteria. In the follow-up, the patients were called for their last control, flexion and extension angles of the wrist and Mayo Wrist Scores, the distance of the plate to the joint line and the angle between the plate and the radial shaft were measured and recorded. RESULTS: A total of 64 distal radius fractures, with a mean age of 46.9 years, and the mean follow-up period 24.9 months were included in this study. There was a significant relationship between the Radial Inclination and Plate-Shaft Angle variables and the Mayo Wrist Score at a 99% confidence interval. Additionally, a relationship was observed between the Radial Height variable and the Mayo Score at a 90% confidence interval. A significant positive association was observed between radial inclination and achieving a Good-to-Excellent Mayo score (OR = 1.28, 95% CI [1.08-1.51], p = 0.004). Plate distance to joint line demonstrated a marginally significant positive association with a Good-to-Excellent Mayo score (OR = 1.31, 95% CI [0.97-1.77], p = 0.077). Univariate analysis revealed a significant negative association between plate-shaft angle and achieving a Good-to-Excellent Mayo score (OR = 0.71, 95% CI [0.52-0.99], p = 0.045). This negative association remained statistically significant in the multivariate analysis (p = 0.016). CONCLUSION: Radial inclination, plate distance to joint line, and angle between plate and radius shaft were identified as significant factors associated with improved Mayo Wrist Scores.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas do Rádio , Humanos , Fraturas do Rádio/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Adulto , Idoso , Resultado do Tratamento , Seguimentos , Estudos Retrospectivos , Amplitude de Movimento Articular , Adulto Jovem , Fraturas do Punho
4.
J Orthop Surg Res ; 19(1): 223, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575946

RESUMO

BACKGROUND: Concomitant injuries to the radiocarpal ligaments may occur during episodes of distal radius fractures, which may not cause acute subluxation or dislocation but can lead to radiocarpal instability and progress over time. This study aimed to analyze the occurrence of ulnar carpal translation (UCT) after open reduction and internal fixation of distal radius fractures and evaluate the associated factors of UCT. METHODS: The retrospective study has been done now and includes patients treated between 2010 and 2020 who had undergone reduction and locking plate fixation of distal radius fractures. We assessed radiographs taken immediately after the operation and at 3 months post-operation, enrolling patients with UCT for evaluation. In addition to demographic data, we evaluated radiographic parameters, including fracture pattern, fragment involvement, and ulnar variance. We also assessed the palmar tilt-lunate (PTL) angle to determine associated rotatory palmar subluxation of the lunate (RPSL). RESULTS: Among the 1,086 wrists, 53 (4.9%) had UCT within 3 months post-operation. The majority of wrists with UCT exhibited normal to minus ulnar variance (49 wrists; mean: -1.1 mm), and 24 patients (45.3%) had concomitant RPSL. Fracture classification was as follows: 19 type A3 (35.8%), 5 type C1 (9.4%), 11 type C2 (20.8%), and 18 type C3 (34.0%). Radial styloid was involved in 20 wrists (37.7%), palmar rim in 18 wrists (34.0%), dorsal rim in 25 wrists (47.2%), and die-punch fractures in 3 wrists (5.7%). Concomitant ulnar styloid fractures were present in 29 wrists (54.7%). CONCLUSION: This study highlights the potential for UCT to occur following reduction and fixation of distal radius fractures, particularly in cases with a more severe fracture pattern and combined with ulnar minus variance. The high incidence of concomitant RPSL provides further evidence for the possibility of associated radiocarpal ligament insufficiency after distal radius fracture.


Assuntos
Luxações Articulares , Fraturas do Rádio , Fraturas da Ulna , Fraturas do Punho , Humanos , Estudos Retrospectivos , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Fraturas do Rádio/complicações , Fixação Interna de Fraturas/efeitos adversos , Fraturas da Ulna/diagnóstico por imagem , Fraturas da Ulna/cirurgia , Placas Ósseas/efeitos adversos , Resultado do Tratamento
5.
J Orthop Surg (Hong Kong) ; 32(1): 10225536241236806, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38430070

RESUMO

PURPOSE: To report preliminary clinical results and safety of 3D-printed patient-specific titanium radial head (RH) prosthesis in treatment of the irreparable RH fractures. MATERIAL AND METHODS: This multi-centric prospective study included 10 patients (6 men and four women, mean age 41 years (range, 25-64 years)). Three cases were classified as Mason type III and 7 cases as type IV. Patients were assessed preoperatively, intraoperatively, and at 1, 6, 12, 24, 36, and 48 weeks postoperatively. Range of motion (ROM), visual analog scale (VAS) score, Disabilities of the Arm, Shoulder and Hand (DASH) score, Mayo Elbow Performance Score (MEPS), radiology imaging, and laboratory blood and urine testing were evaluated. RESULTS: The prostheses were implanted utilizing cemented stems in 5 patients and cementless stems in 5 patients. Intraoperatively, well congruency of a prosthesis with capitellum and radial notch of ulna was observed in all cases. All patients had improvement of ROM, VAS score, DASH score, and MEPS during the postoperative follow-ups. At the final follow-up, mean elbow extension was 6.5° (range, 0°-30°), flexion 145° (range, 125°-150°), supination 79° (range, 70°-80°), and pronation 73.5° (range, 45°-80°). Mean VAS score was 0.3 (range, 0-3), DASH score was 12.35 (range, 1.7-23.3), and MEPS was 99.5 (range, 95-100). Postoperative radiographs demonstrated heterotopic ossification in 2 cases, periprosthetic radiolucency in 2 cases, and proximal radial neck resorption in 2 cases. No one had the evidence of capitellar erosion, implant failure, malpositioning, overstuffing, or symptomatic stem loosening. There was no significant alteration of laboratory results or adverse events related to the 3D-printed prosthesis implantation. CONCLUSION: The preliminary results demonstrated that implantation of the 3D-printed patient-specific titanium RH prosthesis is safe and may be a potential treatment option for irreparable RH fracture.


Assuntos
Articulação do Cotovelo , Prótese de Cotovelo , Fraturas do Rádio , Masculino , Humanos , Feminino , Adulto , Estudos Prospectivos , Titânio , Implantação de Prótese , Articulação do Cotovelo/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Impressão Tridimensional , Resultado do Tratamento , Amplitude de Movimento Articular , Estudos Retrospectivos
6.
J Hand Surg Asian Pac Vol ; 29(2): 140-147, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38494166

RESUMO

Background: The long axis of the radius is a standard reference for measuring radiological parameters in distal radius fractures. However, in patients with severe comminution and anatomical variation with distal radius bowing, it is challenging to assess using the long axis of the radius. The long axis of the ulna can be used as an alternative reference. The aim of this study is to assess the reliability and level of agreement using the long axis of the ulna as an alternative reference in comparison to the long axis of the radius. Methods: Posteroanterior (PA) radiography of the wrist in patients with acute distal radius fractures was evaluated in two rounds by four observers. Radial height, radial inclination and ulnar variance were measured using radial and ulnar long axis as references. The intraobserver and interobserver reliability of the measurements with two reference axes was assessed using intraclass correlation coefficient (ICC). The level of agreement was determined using the Bland-Altman plot. Results: In total, 59 patients who underwent PA radiography of the wrist were included in this study. All parameters exhibited good agreement between the two methods, with a mean difference of nearly zero (radial height = -0.03 mm, radial inclination = -0.14° and ulnar variance = 0.03 mm). The limits of agreement in radial height (-2.87, 2.82 mm) and ulnar variance (-0.81, 0.87 mm) were narrow. However, for the radial inclination, it was wider (-6.21, 5.94°). Intraobserver reliability between the long axis of radius and ulna (ICC = 0.85-0.99 and 0.84-0.98, respectively) was good to excellent. The interobserver reliability of each parameter was excellent (ICC = 0.94-0.97). Conclusions: The ulnar long axis can be used as an alternative reference for measuring radial height, radial inclination and ulnar variance in PA radiography of the wrist in acute distal radius fracture, particularly if the radial long axis is distorted. Level of Evidence: Level III (Diagnostic).


Assuntos
Fraturas do Rádio , Fraturas do Punho , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Fraturas do Rádio/diagnóstico por imagem , Reprodutibilidade dos Testes , Ulna/diagnóstico por imagem , Radiografia
7.
J Hand Surg Asian Pac Vol ; 29(2): 125-133, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38494162

RESUMO

Background: We aim to evaluate the impact of advanced age and sex on postoperative complications and radiographic outcomes after open reduction with internal fixation of distal radius fractures (DRF). Methods: We conducted a retrospective chart review, including all patients who underwent open reduction with internal fixation of a DRF between 2012 and 2018 at a single level 1 trauma centre. We recorded patient age, sex, fracture classification (Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association [AO/OTA]), time from injury to surgical date, surgical duration, diabetes status, tobacco use, illicit drug use, history of osteoporosis, use of adjuvants, fixation type, postoperative radiographic restoration of normal parameters and early complications including loss of reduction within 30 days postoperatively. Advanced age was defined as age greater than 60 years. Results: A total of 521 patients underwent operative treatment - 264 males and 257 females. Males were twice as likely (23.5% vs. 10.1%; p < 0.0001) to sustain a type C3 fracture and be treated with a wrist spanning plate (5.3% vs. 0; p < 0.0001). A larger percentage of elderly patients undergoing operative treatment of DRF were female (20.2% vs. 5.7%; p < 0.0001) and females were more likely to carry a pre-injury diagnosis of osteoporosis (9.3% vs. 0%; p < 0.0001). And 100% of the elderly patients received were treated with a volar plate. The overall early loss of reduction was 7.5%. The overall complication rate was 8.2%. No differences in early postoperative complications were identified between sexes or age groups. Neither female sex nor advanced age was found to have increased risk of postoperative complications or early loss of reduction. Similar postoperative radiographic parameter measurements were obtained across groups as well. Conclusions: Our results support the idea that operative treatment of unstable DRF in elderly patients and women is a reasonable treatment option without significant increases in early postoperative complications. Level of Evidence: Level III (Therapeutic III).


Assuntos
Osteoporose , Fraturas do Rádio , Fraturas do Punho , Masculino , Humanos , Feminino , Idoso , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/epidemiologia , Fraturas do Rádio/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
8.
J Hand Surg Am ; 49(5): 411-422, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38551529

RESUMO

PURPOSE: To review the existing literature to (1) determine the diagnostic efficacy of artificial intelligence (AI) models for detecting scaphoid and distal radius fractures and (2) compare the efficacy to human clinical experts. METHODS: PubMed, OVID/Medline, and Cochrane libraries were queried for studies investigating the development, validation, and analysis of AI for the detection of scaphoid or distal radius fractures. Data regarding study design, AI model development and architecture, prediction accuracy/area under the receiver operator characteristic curve (AUROC), and imaging modalities were recorded. RESULTS: A total of 21 studies were identified, of which 12 (57.1%) used AI to detect fractures of the distal radius, and nine (42.9%) used AI to detect fractures of the scaphoid. AI models demonstrated good diagnostic performance on average, with AUROC values ranging from 0.77 to 0.96 for scaphoid fractures and from 0.90 to 0.99 for distal radius fractures. Accuracy of AI models ranged between 72.0% to 90.3% and 89.0% to 98.0% for scaphoid and distal radius fractures, respectively. When compared to clinical experts, 13 of 14 (92.9%) studies reported that AI models demonstrated comparable or better performance. The type of fracture influenced model performance, with worse overall performance on occult scaphoid fractures; however, models trained specifically on occult fractures demonstrated substantially improved performance when compared to humans. CONCLUSIONS: AI models demonstrated excellent performance for detecting scaphoid and distal radius fractures, with the majority demonstrating comparable or better performance compared with human experts. Worse performance was demonstrated on occult fractures. However, when trained specifically on difficult fracture patterns, AI models demonstrated improved performance. CLINICAL RELEVANCE: AI models can help detect commonly missed occult fractures while enhancing workflow efficiency for distal radius and scaphoid fracture diagnoses. As performance varies based on fracture type, future studies focused on wrist fracture detection should clearly define whether the goal is to (1) identify difficult-to-detect fractures or (2) improve workflow efficiency by assisting in routine tasks.


Assuntos
Inteligência Artificial , Fraturas do Rádio , Osso Escafoide , Humanos , Osso Escafoide/lesões , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Punho
9.
Hand Surg Rehabil ; 43(2): 101674, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38431044

RESUMO

OBJECTIVES: The relationship between volar fragment size and postoperative volar tilt loss in complete articular distal radius fracture is not well known. In this study, we measured precise radiological parameters to help identify other factors that might contribute to volar tilt loss. MATERIAL AND METHODS: We retrospectively reviewed the radiological examinations and charts of 256 patients with distal radial fracture who underwent volar locking plate fixation between March 2014 and July 2022. Radiological parameters were measured based on preoperative CT and immediate postoperative radiographs. Univariate and multivariate linear regression analysis was performed to identify relevant factors associated with volar tilt loss following volar locking plate fixation. The receiver operating characteristic curve was used to identify the cutoff value of the independent parameters. RESULTS: On univariate analysis, 2 radiologic parameters on preoperative CT (volar fragment length at the lunate fossa, and teardrop angle) and 4 on immediate postoperative X-ray (radial inclination, radial length, capitate shift, and volar tilt) were significantly associated with postoperative volar tilt loss. On multivariate linear regression analysis, the risk of volar tilt loss increased as the capitate moved toward the back of the radial shaft. The cut-off for anteroposterior length in the lunate fossa was 6.5 mm. CONCLUSIONS: AO/OTA type-C distal radius fractures with <6.5 mm anteroposterior length in the lunate fossa had significantly higher rates of malunion with dorsal deformity. In addition, preoperative teardrop angle <37.2 ° and immediate postoperative volar tilt <3.7º are also predictors of postoperative volar tilt loss.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas do Rádio , Humanos , Fraturas do Rádio/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Idoso , Tomografia Computadorizada por Raios X , Osso Semilunar/diagnóstico por imagem , Osso Semilunar/cirurgia , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/diagnóstico por imagem , Fraturas do Punho
10.
Ulus Travma Acil Cerrahi Derg ; 30(2): 135-141, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38305653

RESUMO

BACKGROUND: Although isolated distal radius and radial head fractures are common injuries, simultaneous ipsilateral fractures are uncommon. They can range from simple undisplaced fractures at either end to severely comminuted ipsilateral proximal and distal radial fractures. Few cases have been reported with concomitant comminuted distal radius and radial head fractures, and no treatment guidelines are available. Decisions are often based on personal recommendations. The purpose of our study is to increase awareness of this injury pattern and to discuss the mechanism of injury, treatment approach, and functional outcome. METHODS: Skeletally mature patients with comminuted simultaneous ipsilateral fractures of the distal and proximal radius from 2016 to 2021 were identified and studied retrospectively. Demographic information, mechanism of injury, treatment approach, and complication rate were analyzed. Radiographic assessment for inadequacy or loss of reduction and radiographic parameters of the distal radius, including radial inclination, radial length, and palmar inclination, was performed immediately postoperatively and at the final follow-up. Clinical outcomes were determined by calculating the Visual Analog Scale (VAS) score, measuring the range of motion in both joints, and using the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score at the final follow-up. RESULTS: A total of 11 patients met the inclusion criteria. All had ipsilateral Mason III radial head fractures and type C (according to the Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification) intra-articular distal radius fracture. On-table radial head reconstruction and fixation with a proximal radius plate were used for radial head fractures, and osteosynthesis with an anatomic volar locking plate was used for distal radius fractures. The mean follow-up duration was 32 months (range 12-65 months). At the final follow-up, osseous union of both the radial head and distal radius was observed in all patients. The mean VAS score was 1.5 (range 0-7) at rest and 3.9 (range 0-9) with activities, while the mean QuickDASH score was 32 (range 12-65). No significant complications were recorded. CONCLUSION: Simultaneous comminuted fractures of the ipsilateral distal radius and radial head represent a distinct injury pattern, most likely resulting from high-energy trauma, such as falling from a height onto an outstretched hand. Greater emphasis should be placed on clinical examination and radiological imaging of the elbow in cases of wrist injuries and vice versa. Treatment involving on-table reconstruction of the radial head and open reduction and internal fixation with a volar plate can lead to good radiological and functional outcomes.


Assuntos
Fraturas Cominutivas , Fraturas da Cabeça e do Colo do Rádio , Fraturas do Rádio , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Rádio (Anatomia)/lesões , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/cirurgia , Estudos Retrospectivos , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Fixação Interna de Fraturas/métodos , Amplitude de Movimento Articular , Placas Ósseas , Resultado do Tratamento
11.
Sci Rep ; 14(1): 2876, 2024 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-38311631

RESUMO

Forearm rotation restriction (FRR) is common after surgery for distal radius fractures (DRFs). The aim of the current study was to investigate the effect of DRFs on forearm rotation. This retrospective study reviewed patients with DRFs who underwent surgical treatment from January 2019 to December 2021. The patients' basic data and radiographic parameters were analyzed. Forearm rotation, including pronation and supination, was assessed using a standard goniometer. The Patient-Rated Wrist Evaluation (PRWE) score was evaluated, and the incidence of FRR at the 6-month follow-up was recorded. Univariate and multivariate logistic regression analyses were performed to identify risk factors correlated with FRR. A total of 127 patients with DRFs were included in this study. After surgery, 46 cases were considered to have FRR, with a rate of 36.2%, while the remaining 81 cases (63.8%) did not have FRR. The PRWE scores were 22.8 ± 5.2 and 17.9 ± 4.2 in the FRR group and non-FRR group, respectively, and the difference was statistically significant (P < 0.05). Multivariate analysis showed that the involvement of the sigmoid notch (OR, 2.88; 95% CI 1.49-5.56), post-operative volar tilt < 0° (OR, 2.16; 95% CI 1.34-3.50), and post-operative ulnar variance > 0 mm (OR, 1.37; 95% CI 1.06-1.78) were independently associated with the incidence of FRR. The FRR is associated with an increased PRWE score and may have had some impact on the patient's daily life. Fractures involving the sigmoid notch, dorsal angulation, and radial shortening deformity were found to be correlated with the incidence of FRR. Preoperative risk notification and intraoperative preventive measures are necessary for these patients.


Assuntos
Fraturas do Rádio , Fraturas do Punho , Humanos , Pessoa de Meia-Idade , Antebraço/cirurgia , Estudos Retrospectivos , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Articulação do Punho/cirurgia , Amplitude de Movimento Articular , Fixação Interna de Fraturas
12.
Arthroscopy ; 40(2): 318-319, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38296437

RESUMO

For decades, the surgical treatment of intra-articular distal radius fractures has relied on indirect reduction. The goal is to mitigate the articular stepoff that has been associated with radiographic progression of arthritic changes. Continued advances in wrist arthroscopy give us the opportunity for direct visualization of these reductions, direct assessment of intra-articular screws, and diagnosis and treatment of concomitant soft tissue pathology, including those to the scapholunate interosseous ligament, lunotriquetral interosseous ligament, and the triangular fibrocartilage complex. Despite this, however, supplemental wrist arthroscopy does not appear to improve outcomes at 1 year in patients with distal radius fractures treated with volar locking plates.


Assuntos
Fraturas do Rádio , Fraturas do Punho , Traumatismos do Punho , Humanos , Punho , Artroscopia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Fraturas do Rádio/complicações , Articulação do Punho/cirurgia , Traumatismos do Punho/cirurgia
13.
Arch Orthop Trauma Surg ; 144(3): 1179-1188, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38231205

RESUMO

BACKGROUND: There are clear standards for when to operate on both distal epiphyseal and diaphyseal forearm fractures in children. However, paediatric surgeons are often faced with fractures in the transition zone between metaphysis and diaphysis. This aim of the study is to compare different treatment approaches for diametaphyseal forearm fractures, to classify different types of these fractures, and to define further assessment parameters and treatment recommendations. METHODS: This retrospective study included all patients with diametaphyseal radial fractures who were seen at a paediatric surgery clinic between 01.01.2010 and 31.12.2013. Patients were treated either non-surgically (C) or surgically using bicortical Kirschner wire (BC-KW), intramedullary K-wire (IM-KW), elastic stable intramedullary nailing (ESIN), or combined bicortical and intramedullary K-wire (BCIM-KW). RESULTS: During the study period, 547 patients presented with forearm fractures of which 88 patients (16%) had a fracture in the diametaphyseal region. The majority of diametaphyseal fractures were greenstick fractures (54.4%) followed by transverse fractures (44.3%). Distal fractures were predominantly treated with bicortical K-wiring (BC-KW, 40.5%) or non-surgically (C, 26.2%). Proximal fractures were treated by ESIN osteosynthesis (50%), followed by IM-KW (30%). Intermediate fractures were just as likely to be treated with one out of the 5 above-mentioned techniques. The ulna was involved in 64 of 88 cases. Depending on the type of fracture, it was treated either by ESIN osteosynthesis or non-surgically. No superior operative technique was identified. CONCLUSIONS: The description of diametaphyseal fractures as a separate entity is important, because the therapy of these fractures is heterogeneous and challenging. A classification into proximal, intermediate, and distal may be useful in clinical decision-making. Despite the retrospective nature of this study, our data suggest that the use of a K-wire or combined technique BCIM-KW-technique, whenever technically feasible, achieves better radiological results without secondary dislocation. Further prospective studies are needed to provide better guidance to trauma surgeons.


Assuntos
Traumatismos do Antebraço , Fixação Intramedular de Fraturas , Fraturas do Rádio , Criança , Humanos , Estudos Retrospectivos , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Rádio (Anatomia) , Traumatismos do Antebraço/complicações , Traumatismos do Antebraço/cirurgia , Fixação Interna de Fraturas , Fixação Intramedular de Fraturas/efeitos adversos , Resultado do Tratamento , Pinos Ortopédicos
14.
Eur J Trauma Emerg Surg ; 50(1): 37-47, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38261077

RESUMO

PURPOSE: There is a debate whether corrective osteotomies of the distal radius should be performed using a 3D work-up with pre-contoured conventional implants (i.e., of-the-shelf) or patient-specific implants (i.e., custom-made). This study aims to assess the postoperative accuracy of 3D-assisted correction osteotomy of the distal radius using either implant. METHODS: Twenty corrective osteotomies of the distal radius were planned using 3D technologies and performed on Thiel embalmed human cadavers. Our workflow consisted of virtual surgical planning and 3D printed guides for osteotomy and repositioning. Subsequently, left radii were fixated with patient-specific implants, and right radii were fixated with pre-contoured conventional implants. The accuracy of the corrections was assessed through measurement of rotation, dorsal and radial angulation and translations with postoperative CT scans in comparison to their preoperative virtual plan. RESULTS: Twenty corrective osteotomies were executed according to their plan. The median differences between the preoperative plan and postoperative results were 2.6° (IQR: 1.6-3.9°) for rotation, 1.4° (IQR: 0.6-2.9°) for dorsal angulation, 4.7° (IQR: 2.9-5.7°) for radial angulation, and 2.4 mm (IQR: 1.3-2.9 mm) for translation of the distal radius, thus sufficient for application in clinical practice. There was no significant difference in accuracy of correction when comparing pre-contoured conventional implants with patient-specific implants. CONCLUSION: 3D-assisted corrective osteotomy of the distal radius with either pre-contoured conventional implants or patient-specific implants results in accurate corrections. The choice of implant type should not solely depend on accuracy of the correction, but also be based on other considerations like the availability of resources and the preoperative assessment of implant fitting.


Assuntos
Fraturas Mal-Unidas , Fraturas do Rádio , Cirurgia Assistida por Computador , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Cirurgia Assistida por Computador/métodos , Fraturas Mal-Unidas/cirurgia , Osteotomia/métodos
15.
Eur J Orthop Surg Traumatol ; 34(3): 1413-1418, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38227012

RESUMO

INTRODUCTION: Radial neck fractures in adults are rare, but outcomes are often poor. Closed reduction and internal fixation (CRIF) technique has been advocated for the treatment of minimally displaced fractures in children, with a few reports on adult subjects. The aim of the present paper is to investigate mid-term results of a CRIF technique in adults with retrograde intramedullary K-wires in Mason's type II and III fractures. The proposed technique yields to good anatomical reduction of displaced neck fractures, faster rehabilitation, and easier hardware removal after fracture consolidation. MATERIAL AND METHODS: A consecutive series of 17 patients were treated with closed reduction and intramedullary osteosynthesis, and outcomes were retrospectively evaluated. Elbow X-ray (XR) and CT scan were obtained preoperatively. Objective assessment before surgery and at an average 36-month follow-up included active and passive elbow range of motion (ROM). Functional evaluation was carried out through the collection of the Mayo Elbow Performance Score (MEPS), the Disabilities of the Arm, Shoulder, and Hand (DASH) score, and Elbow Self-Assessment Score (ESAS). XR at last follow-up was evaluated. RESULTS: The cohort included 10 males and seven females, with a mean age of 32 years. Patients returned for a follow-up evaluation at a mean of 36 months (range 6-43 m) form the surgery. The DASH score revealed good to excellent outcomes with a mean of 6.32 ± 10.24 points at last follow-up. The ESAS was 98.35 ± 1.89, indicating a non-restricted elbow function. Acceptable radiographic healing was achieved in all patients. CONCLUSIONS: The advocated technique is promising for obtaining good reduction and stabilization, and good to excellent satisfaction for patients. Given the challenging technique, the learning curve could be long and initial results unsatisfactory. More research with larger cohorts and improved study design could be carried out, comparing the technique with the current choice of treatment (ORIF, radial head resection).


Assuntos
Articulação do Cotovelo , Fixação Intramedular de Fraturas , Fraturas da Cabeça e do Colo do Rádio , Fraturas do Rádio , Masculino , Adulto , Criança , Feminino , Humanos , Cotovelo , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Fraturas do Rádio/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Pinos Ortopédicos , Fixação Intramedular de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/cirurgia , Amplitude de Movimento Articular
17.
BMJ Case Rep ; 17(1)2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38286584

RESUMO

A child sustained an ipsilateral supracondylar humerus (SCH) and distal both-bone forearm fractures bilaterally, in addition to facial injuries, following a fall from height. He was managed surgically by closed reduction and pinning for both SCH and distal end radius fractures bilaterally. At the final follow-up, all the fractures had united uneventfully, and he had no functional limitations or cosmetic concerns. We conclude that a floating elbow in the paediatric population is an uncommon injury, and the bilateral scenario is even rarer. One should be vigilant for compartment syndrome; early surgical fixation may give better results.


Assuntos
Lesões no Cotovelo , Fraturas do Úmero , Fraturas do Rádio , Masculino , Humanos , Criança , Cotovelo/diagnóstico por imagem , Fraturas do Úmero/complicações , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia , Antebraço , Fraturas do Rádio/complicações , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Estudos Retrospectivos
18.
J Hand Surg Am ; 49(3): 203-211, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38069952

RESUMO

PURPOSE: Current guidelines recommend bone mineral density (BMD) testing after fragility fractures in patients aged 50 years or older. This study aimed to assess BMD testing and subsequent fragility fractures after low-energy distal radius fractures (DRFs) among patients aged 50-59 years. METHODS: We used the 2010-2020 MarketScan dataset to identify patients with initial DRFs with ages ranging between 50 and 59 years. We assessed the 1-year BMD testing rate and 3-year non-DRF fragility fracture rate. We created Kaplan-Meier plots to depict fragility fracture-free probabilities over time and used log-rank tests to compare the Kaplan-Meier curves. RESULTS: Among 78,389 patients aged 50-59 years with DRFs, 24,589 patients met our inclusion criteria, and most patients were women (N = 17,580, 71.5%). The BMD testing rate within 1 year after the initial DRF was 12.7% (95% CI, 12.3% to 13.2%). In addition, 1-year BMD testing rates for the age groups of 50-54 and 55-59 years were 10.4% (95% CI, 9.9% to 11.0%) and 14.9% (95% CI, 14.2% to 15.6%), respectively. Only 1.8% (95% CI, 1.5% to 2.1%) of men, compared with 17.1% (95% CI, 16.5% to 17.7%) of women, underwent BMD testing within 1 year after the initial fracture. The overall 3-year fragility fracture rate was 6.0% (95% CI, 5.6% to 6.3%). The subsequent fragility fracture rate was lower for those with any BMD testing (4.4%; 95% CI, 3.7% to 5.2%), compared with those without BMD testing (6.2%; 95% CI, 5.9% to 6.6%; P < .05). CONCLUSIONS: We report a low BMD testing rate for patients aged between 50 and 59 years after initial isolated DRFs, especially for men and patients aged between 50 and 54 years. Patients who received BMD testing had a lower rate of subsequent fracture within 3 years. We recommend that providers follow published guidelines and initiate an osteoporosis work-up for patients with low-energy DRFs to ensure early diagnosis. This provides an opportunity to initiate treatment that may prevent subsequent fractures. TYPE OF STUDY/LEVEL OF EVIDENCE: Prognosis II.


Assuntos
Fraturas Ósseas , Osteoporose , Fraturas por Osteoporose , Fraturas do Rádio , Fraturas do Punho , Estados Unidos/epidemiologia , Masculino , Humanos , Idoso , Feminino , Pessoa de Meia-Idade , Densidade Óssea , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/terapia , Medicare , Osteoporose/complicações , Osteoporose/diagnóstico , Fraturas por Osteoporose/prevenção & controle
19.
Eur J Orthop Surg Traumatol ; 34(2): 1121-1130, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37962633

RESUMO

PURPOSE: It is generally accepted that a radial head fracture (RHF) with more than three parts is not suitable for repair; therefore, most authors suggest straightforward radial head arthroplasty (RHA). With up to 20% risk for reoperation after RHA, improvement in reduction and fixation techniques may represent a valuable alternative before further extending the indications for arthroplasty. To determine the functional results and radiological failure rate after osteosynthesis of multi-fragmentary RHF with more than three articular fragments. We specifically determined (1) the one-year Broberg and Morrey functional elbow score, (2) duration of fracture healing, (3) complication rate, and (4) number of patients converted to RHA. METHODS: This study is a retrospective single-center case series. All patients who underwent primary osteosynthesis for RHF between 2012 and 2019 were included. Nine patients with an average age of 52 years had an average clinical and/or radiological follow-up of 49 months. RESULTS: The preoperative imaging identified nine fractures with four fragments. Three patients underwent osteosynthesis with plates and screws, whereas six patients underwent osteosynthesis with only screws. The mean Broberg and Morrey score was 95 points. Overall, eight of the nine patients had satisfactory results. All patients retained their radial heads and showed radiological fracture healing. Only two patients presented with low-grade complications requiring no further surgery. CONCLUSION: Our study showed that osteosynthesis of RHF with up to four fragments can achieve good functional results with a low complication rate and seems to be a valid alternative to RHA.


Assuntos
Articulação do Cotovelo , Fraturas da Cabeça e do Colo do Rádio , Fraturas do Rádio , Humanos , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Resultado do Tratamento , Rádio (Anatomia)/cirurgia , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Fraturas do Rádio/etiologia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos
20.
J Pediatr Orthop B ; 33(2): 178-183, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37266956

RESUMO

We assessed the radiological and functional results of pediatric both-bone forearm diaphyseal fractures treated using elastic stable intramedullary nails (ESINs), as well as factors affecting the results. In total, 36 patients (33 males and three females; mean age, 11.6 years) were included. The mean follow-up time was 41.5 (18-96) months. Patient demographic characteristics and the details of the surgical techniques were analyzed retrospectively. In addition to standard radiographic evaluations, the ratio between the nail diameter and medullary canal diameter (ND/MCD) was measured, as well as the maximal radial bowing. According to the criteria of Price and Flynn, 28 (77.8%) and eight (22.2%) patients had excellent and good results, respectively. There were no cases of nonunion or delayed union. There was no significant difference in functional or radiological results according to whether titanium nails (24 patients) or stainless steel nails (12 patients) were used (all P  > 0.05). Nail prebending (performed in 19 patients) did not affect the functional or radiological results ( P  > 0.05). Loss of reduction was observed in four patients with an ND/MCD ratio <40%. The maximal radial bowing improved in all patients. The mean change was significantly greater in patients with diastases and 22D/4.1 fractures. Regardless of nail type or prebending status, surgery using ESIN placement effectively treats both-bone forearm diaphyseal fractures; radial bow remodeling outcomes are excellent. We recommend that the ND/MCD ratio should be 40-70%.


Assuntos
Fixação Intramedular de Fraturas , Fraturas Ósseas , Fraturas do Rádio , Masculino , Feminino , Humanos , Criança , Antebraço , Estudos Retrospectivos , Pinos Ortopédicos , Fraturas Ósseas/cirurgia , Fixação Intramedular de Fraturas/métodos , Resultado do Tratamento , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Consolidação da Fratura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA