Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 475
Filtrar
1.
J Orthop Surg Res ; 19(1): 302, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760662

RESUMO

PURPOSE: To analyze the association between scoliosis and vertebral refracture after percutaneous kyphoplasty (PKP) in patients with osteoporotic vertebral compression fractures (OVCFs). METHODS: A retrospective study was conducted on 269 patients meeting the criteria from January 2014 to October 2022. All patients underwent PKP with complete data and were followed-up for > 12 months. First, it was verified that scoliosis was a risk factor in 269 patients. Second, patients with scoliosis were grouped based on the Cobb angle to evaluate the impact of the post-operative angle. The cox proportional hazards regression analysis and survival analysis were used to calculate the hazard ratio and recurrence time. RESULTS: A total of 56 patients had scoliosis, 18 of whom experienced refractures after PKP. The risk factors for vertebral refractures included a T-score < - 3.0 and presence of scoliosis (both p < 0.001). The results indicated that the vertebral fractured arc (T10 - L4) was highly influential in scoliosis and vertebral fractures. When scoliotic and initially fractured vertebrae were situated within T10 - L4, the risk factors for vertebral refracture included a postoperative Cobb angle of ≥ 20° (p = 0.002) and an increased angle (p = 0.001). The mean recurrence times were 17.2 (10.7 - 23.7) months and 17.6 (7.9 - 27.3) months, respectively. CONCLUSION: Osteoporosis combined with scoliosis significantly increases the risk of vertebral refractures after PKP in patients with OVCFs. A postoperative Cobb angle of ≥ 20° and an increased angle are significant risk factors for vertebral refractures when scoliotic and initially fractured vertebrae are situated within T10 - L4.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas por Osteoporose , Recidiva , Escoliose , Fraturas da Coluna Vertebral , Humanos , Fraturas por Compressão/cirurgia , Fraturas por Compressão/etiologia , Fraturas por Compressão/diagnóstico por imagem , Cifoplastia/métodos , Feminino , Escoliose/cirurgia , Escoliose/etiologia , Escoliose/diagnóstico por imagem , Masculino , Fraturas da Coluna Vertebral/cirurgia , Fraturas da Coluna Vertebral/etiologia , Fraturas da Coluna Vertebral/diagnóstico por imagem , Estudos Retrospectivos , Fraturas por Osteoporose/cirurgia , Fraturas por Osteoporose/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Fatores de Risco , Pessoa de Meia-Idade , Seguimentos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia
2.
J Orthop Surg Res ; 19(1): 240, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622736

RESUMO

OBJECTIVE: To assess the radiographic outcomes, clinical outcomes and complications of percutaneous kyphoplasty (PKP) with and without posterior pedicle screw fixation (PPSF) in the treatment of severe osteoporotic vertebral compression fractures (sOVCF) with nonunion. METHODS: This study involved 51 patients with sOVCF with nonunion who underwent PKP or PPSF + KP. The operation time, intraoperative blood loss, volume of injected bone cement, operation costs and hospital stays were all recorded. In addition, the Visual Analogue Scale (VAS) and the Oswestry Disability Index (ODI) were assessed separately for each patient before and after surgery. RESULTS: Compared with the PPSF + KP group, the PKP group had shorter operation time, less intraoperative blood loss, shorter hospital stays and fewer operation costs. However, cobb's angle improvement (13.4 ± 4.3° vs. 21.4 ± 5.3°), VWR improvement ratio (30.4 ± 11.5% vs. 52.8 ± 12.7%), HA (34.9 ± 9.0% vs. 63.7 ± 7.6%) and HM (28.4 ± 11.2% vs. 49.6 ± 7.7%) improvement ratio were all higher in PPSF + KP group than that in PKP group. In addition, the ODI index and VAS score in both groups were significantly decreased at the postoperative and final follow-up. PKP group's postoperative VAS score was significantly lower than that in PPSF + KP group, but there was no statistically significant difference in VAS score at the last follow-up. CONCLUSION: PKP and PPSF + KP can both effectively relieve the pain associated with sOVCF with nonunion. PPSF + KP can achieve more satisfactory vertebral reduction effects compared to PKP. However, PKP was less invasive and it has more advantages in shortening operation time and hospital stay, as well as decreasing intraoperative blood loss and operation costs.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas por Osteoporose , Parafusos Pediculares , Fraturas da Coluna Vertebral , Humanos , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/cirurgia , Fraturas por Compressão/tratamento farmacológico , Perda Sanguínea Cirúrgica , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Fraturas da Coluna Vertebral/tratamento farmacológico , Resultado do Tratamento , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/cirurgia , Fraturas por Osteoporose/tratamento farmacológico , Cimentos Ósseos/uso terapêutico , Estudos Retrospectivos
3.
BMC Musculoskelet Disord ; 25(1): 294, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627655

RESUMO

PURPOSE: To assess the clinical safety, accuracy, and efficacy of percutaneous kyphoplasty (PKP) surgery using an enhanced method of unilateral puncture on the convex side for the treatment of painful osteoporotic vertebral compression fractures (P-OVCF) with scoliosis. METHODS: Clinical and radiographic data of P-OVCF patients with scoliosis who underwent PKP via unilateral puncture on the convex side from January 2018 to December 2021 were retrospectively analyzed. This technique's detailed surgical steps and tips were described. The local kyphosis angle (LKA), scoliosis Cobb angle (SCA), and local scoliosis Cobb angle (LSCA) were measured using X-ray and compared at pre-operation, post-operation, and the last follow-up. The width of pedicle (POW), inner inclination angle (IIA), lateral distance (LD), and puncture course length (PCL) were measured on the axial computed tomography image and compared between two sides. Postoperative computed tomography was employed to evaluate the condition of cement distribution and puncture. Clinical outcomes were evaluated using the Oswestry Disability Index (ODI) and Visual Analog Scale (VAS) for back pain (BP). RESULTS: Thirty-six patients, 23 women and 13 men, with an average age of 76.31 ± 6.28 years were monitored for 17.69 ± 4.70 months. The median surgical duration of single vertebrae was 35 min. The volume of bone cement for single vertebrae was 3.81 ± 0.87 ml and the proportion of sufficient cement distribution of the patients was 97.22. LKA was considerably improved from pre-operation to post-operation and sustained at the last follow-up. SCA and LSCA were not significantly modified between these three-time points. IIA, PCL, and LD were lower on the convex side than on the concave side. POW was considerably wider on the convex side. The ODI and VAS-BP scores were significantly improved after surgery and sustained during the follow-up. CONCLUSIONS: Combining with the proper assessment of the pre-injured life status of patients, PKP surgery using unilateral puncture on the convex side for the treatment of P-OVCF with scoliosis can achieve safe, excellent clinical, and radiographic outcomes.


Assuntos
Fraturas por Compressão , Cifoplastia , Cifose , Fraturas por Osteoporose , Escoliose , Fraturas da Coluna Vertebral , Masculino , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Cifoplastia/métodos , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/etiologia , Fraturas por Compressão/cirurgia , Escoliose/complicações , Escoliose/diagnóstico por imagem , Estudos Retrospectivos , Fraturas da Coluna Vertebral/complicações , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Resultado do Tratamento , Coluna Vertebral , Cimentos Ósseos/uso terapêutico , Punções , Cifose/diagnóstico por imagem , Cifose/etiologia , Cifose/cirurgia , Fraturas por Osteoporose/complicações , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/cirurgia
4.
BMC Musculoskelet Disord ; 25(1): 295, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627756

RESUMO

BACKGROUND: Early assessment of the risk of nonunion in osteoporotic vertebral compression fracture (OVCF) is beneficial to early clinical decision making. However, a comprehensive understanding of the risk factors for OVCF nonunion is lacking. METHODS: We conducted a case-control study to investigate risk factors for OVCF nonunion. Patients who underwent surgery for nonunited OVCFs between January 2011 and December 2021 were eligible for inclusion as cases. Patients with successful OVCF healing confirmed by MRI over the same period were identified as controls. Patient demographics, comorbidities, and fasting blood test data were extracted for analysis. RESULTS: A total of 201 patients with nonunited OVCFs and 1044 controls were included to evaluate the risk factors for nonunited OVCFs. There were statistically significant differences in sex, age, number of patients with hypertension, number of patients on bed rest after OVCF and T-score of BMD between the two groups. Logistic regression showed that female patients had a higher risk of OVCF nonunion than male patients and that smoking, drinking, diabetes, and hypertension were risk factors for nonunion of OVCFs, while bed rest and spinal support were protective factors against nonunion of OVCFs. We also found that age, BMD, FBG, and ß-CTX were positively correlated with nonunited OVCFs, and that HGB and 1,25-(OH)2VitD3 level were negatively correlated with nonunited OVCFs. CONCLUSION: Smoking, drinking, diabetes and hypertension were risk factors for nonunion of OVCFs, while bed rest and spinal support were protective factors against nonunion of OVCFs. Age, BMD, FBG and ß-CTX were positively correlated with nonunited OVCFs, while HGB and 1,25-(OH)2VitD3 level were negatively correlated with nonunited OVCFs. Based on the results of our study, we suggest that bed rest or spinal support for at least 3 consecutive weeks is necessary to reduce the risk of OVCFs nonunion.


Assuntos
Diabetes Mellitus , Fraturas por Compressão , Hipertensão , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Humanos , Masculino , Feminino , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/epidemiologia , Fraturas da Coluna Vertebral/etiologia , Estudos de Casos e Controles , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/epidemiologia , Fraturas por Compressão/cirurgia , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/epidemiologia , Fraturas por Osteoporose/etiologia , Fatores de Risco , Estudos Retrospectivos , Resultado do Tratamento
5.
Turk Neurosurg ; 34(2): 250-255, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38497177

RESUMO

AIM: To compare the clinical and radiological outcomes of unilateral percutaneous kyphoplasty (PKP) surgeries performed using 3D printing technology in patients with osteoporotic compression fractures to conventional unilateral PKP surgeries. MATERIAL AND METHODS: Patients with acute painful single-level osteoporotic vertebral compression fracture (OVCF) who need surgical treatment were divided into two groups: group A (patients who had 3D template-guided PKP) and group B (patients who conventional PKP). To compare the two surgical procedures, Total Absorbed Radiation Dose (TARD), pre- and postoperative visual analog scale (VAS) scores, and Total Surgery Time (TST) were calculated and compared between groups in both surgical groups. RESULTS: A total of 44 patients with single-level OVCF who were experiencing acute pain were successfully operated on, with 22 patients in each group. TARD (2.6 ± 0.4 mGy vs. 6.1 ± 1.9 mGy, p < 0.05) and TST (12.4 ± 2.6 min vs. 20.2 ± 3.2 min, p < 0.05) differed significantly different between groups A and B. There was no statistically significant difference between the patient groups in preoperative and postoperative VAS values (p > 0.05). Cement leakage was lower in group A (3/22, 13.6%) than in group B (6/22, 27.3%) (p > 0.05). There were no neurological complications or infections in either group. CONCLUSION: When compared to the conventional procedure, the unilateral percutaneous kyphoplasty method was supported by a 3D printing guide template. By reducing operative time and radiation exposure, tt has resulted in a more effective surgical procedure for patients and a safer surgical procedure for surgeons and anaesthesiologists.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Vertebroplastia , Humanos , Cifoplastia/efeitos adversos , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/cirurgia , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Coluna Vertebral , Vertebroplastia/métodos , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/cirurgia
6.
J Med Case Rep ; 18(1): 55, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38351016

RESUMO

INTRODUCTION: Electrical injuries rarely result in fractures, such as long bone fractures and spinal fractures. A few articles have reported osteoporosis vertebral compression fractures (OVCFs) caused by electrical injuries. Here, we present a rare case of 37-year-old male suffering from the 9th thoracic (T9) and 5th lumbar (L5) OVCFs after receiving a electric shock. CASE PRESENTATION: A 37-year-old Han male experienced an electric shock (480 V direct current) at the working time and felt immediately serious back pain. He did not fall and lose consciousness. X-ray and magnetic resonance imaging showed acute OVCFs, as well as dual-energy X-ray absorptiometry indicated osteoporosis. Normal laboratory tests can avoid secondary osteoporosis resulting from metabolic diseases and tumors. Finally, he was diagnosed with acute discontinuous OVCFs (T9 and L5). The patient denied having a history of back pain, whereas, he had a history of smoking, alcohol abuse, and congenital heart disease (tetralogy of Fallot) were associated with osteoporosis. Considering no local kyphosis and < 50% anterior body compression, we selected conservative treatment for this patient. At a 1-year and 3-year follow-up, the lateral thoracic and lumbar radiography demonstrated no instability of the spine, and the back pain has been relieved. CONCLUSIONS: This rare case reminds us the importance of consulting a detailed medical history when we encounter young patients receiving electrical injuries. Discontinuously OVCFs must not be overlooked, even though we encounter a young man.


Assuntos
Fraturas por Compressão , Osteoporose , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Humanos , Masculino , Adulto , Fraturas da Coluna Vertebral/complicações , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas por Compressão/complicações , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Osteoporose/complicações , Fraturas por Osteoporose/diagnóstico por imagem , Resultado do Tratamento , Osteoporose/complicações , Dor nas Costas/etiologia , Vértebras Lombares/diagnóstico por imagem
7.
Acta Orthop ; 95: 8-13, 2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38240180

RESUMO

BACKGROUND AND PURPOSE: We aimed to evaluate the clinical outcomes, radiographic results, and health-related quality of life in pediatric AO type A1 spinal compression fractures treated with activity-restriction only. PATIENTS AND METHODS: All children between 2014 and 2020 with an AO type A1 spinal compression fracture treated with activity-restriction only identified from an institutional fracture registry were invited to a prospective outcomes study. Clinical findings and spinal radiographs were assessed at median 3 years, interquartile range (IQR) 1-4 follow-up from injury. Oswestry Disability Index, Pediatric Quality of Life Inventory Generic Core Scale (PedsQL), and PedsQL Pediatric Pain Questionnaire were compared with reference values. 63 children were identified, of whom 47 agreed to participate. 8 were polytrauma patients. RESULTS: Age at injury was median 11 (IQR 9-14) years. The number of injured vertebrae was median 2 (IQR 1-3). 82% (94 of 115) were thoracic vertebrae fractures and 70% (33 of 47) of the patients had thoracic vertebrae fractures only. At follow-up all but 2 fractures showed radiographic remodeling. There was no difference from the published reference values in the patient-reported outcome measures. A lower PedsQL physical functioning score was associated with higher patient-reported pain (P = 0.03). At follow-up 12 patients had hyperkyphosis (median difference from the reference values 4°, IQR 3-6, 95% confidence interval [CI] 3-6) and 5 hypolordosis (median difference from reference 8°, IQR 4-11, CI 4-14). None of the patients had surgery for deformity during follow-up. CONCLUSION: Clinical, radiographic, and health-related quality of life outcomes were good after activity-restriction treatment in pediatric A1 spinal compression fractures.


Assuntos
Fraturas por Compressão , Fraturas da Coluna Vertebral , Humanos , Criança , Adolescente , Estudos Prospectivos , Seguimentos , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/cirurgia , Qualidade de Vida , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Dor
8.
World Neurosurg ; 182: e644-e651, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38065359

RESUMO

OBJECTIVE: To analyze the risk factors of new adjacent vertebral fractures (AVF) and remote vertebral fractures (RVF) after percutaneous vertebroplasty (PVP) for osteoporotic vertebral compression fractures (OVCFs). METHODS: Patients who underwent additional PVP for new OVCFs were enrolled. In addition, we set a 1:1 age-, sex-, surgical segment-, and surgical date-matched control group, in which patients underwent PVP without new OVCFs. Data on body mass index, occurrence time of second PVP, vertebral computed tomography (CT) Hounsfield Unit (HU) at the fracture adjacent segment, and RVF segment were collected. RESULTS: A total of 44 patients who underwent additional PVP for new OVCFs at our hospital were included. AVF occurred significantly earlier than RVF (13.5 ± 14.1 vs. 30.4 ± 20.1 months, P = 0.007). Compared to the control group, the AVF segment CT HU was significantly lower in patients with AVF (28.7 ± 16.7 vs. 61.3 ± 14.7, P = 0.000), while there was no significant difference between patients with RVF and control group including both adjacent and RVF segment CT HU. Receiver operating characteristic curves identified a cutoff value of 43 for using adjacent segment CT HU to differentiate patients with AVF from controls, with a sensitivity of 80% and a specificity of 88.9%. CONCLUSIONS: Our study showed that the risk factors for AVF and RVF after PVP surgery were different. The occurrence of AVF was earlier and associated with low adjacent segment CT HU values, whereas the preoperative CT HU in both adjacent and RVF segments was not found to be associated with RVF.


Assuntos
Fraturas por Compressão , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Vertebroplastia , Humanos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/etiologia , Fraturas da Coluna Vertebral/cirurgia , Vertebroplastia/efeitos adversos , Vertebroplastia/métodos , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/cirurgia , Fraturas por Compressão/complicações , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/cirurgia , Fraturas por Osteoporose/complicações , Fatores de Risco , Estudos Retrospectivos , Resultado do Tratamento , Cimentos Ósseos
9.
J Bone Joint Surg Am ; 106(2): 138-144, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-37967162

RESUMO

BACKGROUND: Operative management of minimally displaced lateral compression type-1 (LC1) pelvic ring injuries remains controversial. We aimed to assess the proportion of LC1 pelvic fractures that displaced following nonoperative management as a function of specific ring fracture patterns, and we quantified the magnitude of this displacement. METHODS: A retrospective review of the billing registry of a level-I trauma center was performed. Two hundred and seventy-three patients with a high-energy LC1 pelvic ring fracture and <5 mm of sacral displacement were included. The fracture pattern was characterized with use of computed tomography (CT) scans and radiographs. Absolute and interval pelvic ring displacement were quantified with use of previously described methodology. RESULTS: Thirty-five pelvic ring injuries (13%) were displaced. The rate of displacement was 31% (15 of 49) for LC1 injuries involving a complete sacral fracture and bilateral ramus fractures, 12% (7 of 58) for injuries involving a complete sacral fracture and a unilateral ramus fracture, and 10% (5 of 52) for injuries involving an incomplete sacral fracture and bilateral ramus fractures. In displaced injuries, the average interval displacement was 4.2 mm (95% confidence interval [CI], 1.8 to 6.8) and the final displacement was 9.9 mm ± 4.2 mm. CONCLUSIONS: Our study suggests that fracture characteristics can be used to predict the likelihood of displacement of LC1 fractures that are treated without surgery. To our knowledge, the present study is the first to describe the magnitude of displacement that may occur in association with LC1 pelvic ring injuries that are treated nonoperatively; however, further studies are needed to determine the clinical impact of this displacement. LEVEL OF EVIDENCE: Diagnostic Level IV . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fraturas Ósseas , Fraturas por Compressão , Ossos Pélvicos , Fraturas da Coluna Vertebral , Humanos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Sacro/diagnóstico por imagem , Sacro/lesões , Fraturas por Compressão/diagnóstico por imagem , Ossos Pélvicos/lesões , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Radiografia , Estudos Retrospectivos
10.
Artigo em Inglês | MEDLINE | ID: mdl-37422853

RESUMO

BACKGROUND: Sarcopenia and bone loss are both common in older individuals. However, the association between sarcopenia and bone fractures has not been evaluated longitudinally. In this study, we evaluated the association between computed tomography (CT)-based erector spinae muscle area and attenuation and vertebral compression fracture (VCF) in elderly individuals in a longitudinal study. METHODS: This study recruited individuals 50 years of age and older, who did not have VCF and underwent CT imaging for lung cancer screening during January 2016 to December 2019. Participants were followed up annually until January 2021. Muscle CT value and muscle area of the erector spinae were determined for muscle assessment. Genant score was used to define new-onset VCF. Cox proportional hazards models were used to assess the association between muscle area/attenuation and VCF. RESULTS: Of the 7 906 included participants, 72 developed new VCF over a median follow-up of 2 years. Large area of the erector spinae (adjusted hazard ratio [HR] = 0.2, 95% confidence interval [CI]: 0.1-0.7) and high bone attenuation (adjusted HR = 0.2, 95% CI: 0.1-0.5) were independently associated with VCF. High muscle attenuation was associated with severe VCF (adjusted HR = 0.46, 95% CI: 0.24-0.86). The addition of muscle area improved the area under the curve of bone attenuation from 0.79 (95% CI: 0.74-0.86) to 0.86 (95% CI: 0.82-0.91; p = .001). CONCLUSIONS: CT-based muscle area/attenuation of the erector spinae was associated with VCF in elderly individuals, independently of bone attenuation. The addition of muscle area improved the performance of bone attenuation in predicting VCF.


Assuntos
Doenças Ósseas Metabólicas , Fraturas por Compressão , Neoplasias Pulmonares , Sarcopenia , Fraturas da Coluna Vertebral , Humanos , Idoso , Estudos Longitudinais , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/etiologia , Sarcopenia/complicações , Sarcopenia/diagnóstico por imagem , Detecção Precoce de Câncer , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/etiologia , Tomografia Computadorizada por Raios X/métodos , Músculos , Estudos Retrospectivos
11.
Acad Radiol ; 31(2): 605-616, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37586940

RESUMO

RATIONALE AND OBJECTIVES: This study aimed to develop and validate a magnetic resonance imaging (MRI)-based radiomics nomogram combining radiomics signatures and clinical factors to differentiate between benign and malignant vertebral compression fractures (VCFs). MATERIALS AND METHODS: A total of 189 patients with benign VCFs (n = 112) or malignant VCFs (n = 77) were divided into training (n = 133) and validation (n = 56) cohorts. Radiomics features were extracted from MRI T1-weighted images and short-TI inversion recovery images to develop the radiomics signature, and the Rad score was constructed using least absolute shrinkage and selection operator regression. Demographic and MRI morphological characteristics were assessed to build a clinical factor model using multivariate logistic regression analysis. A radiomics nomogram was constructed based on the Rad score and independent clinical factors. Finally, the diagnostic performance of the radiomics nomogram, clinical model, and radiomics signature was validated using receiver operating characteristic and decision curve analysis (DCA). RESULTS: Six features were used to build a combined radiomics model (combined-RS). Pedicle or posterior element involvement, paraspinal mass, and fluid sign were identified as the most important morphological factors for building the clinical factor model. The radiomics signature was superior to the clinical model in terms of the area under the curve (AUC), accuracy, and specificity. The radiomics nomogram integrating the combined-RS, pedicle or posterior element involvement, paraspinal mass, and fluid sign achieved favorable predictive efficacy, generating AUCs of 0.92 and 0.90 in the training and validation cohorts, respectively. The DCA indicated good clinical usefulness of the radiomics nomogram. CONCLUSION: The MRI-based radiomics nomogram, combining the radiomics signature and clinical factors, showed favorable predictive efficacy for differentiating benign from malignant VCFs.


Assuntos
Fraturas por Compressão , Fraturas da Coluna Vertebral , Humanos , Radiômica , Fraturas por Compressão/diagnóstico por imagem , Nomogramas , Fraturas da Coluna Vertebral/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Retrospectivos
12.
Spine J ; 24(1): 137-145, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37734495

RESUMO

BACKGROUND CONTEXT: Conventional external beam radiation therapy (cEBRT) is used in multiple myeloma (MM) to treat severe pain, spinal cord compression, and disease-related bone disease. However, radiation may be associated with an increased risk of vertebral compression fractures (VCFs), which could substantially impair survival and quality of life. Additionally, the use of the Spinal Instability Neoplastic Score (SINS) in MM is debated in MM. PURPOSE: To determine the incidence of VCFs after cEBRT in patients with MM and to assess the applicability of the SINS score in the prediction of VCFs in MM. STUDY DESIGN: Retrospective multicenter cohort study. PATIENT SAMPLE: MM patients with spinal myeloma lesions who underwent cEBRT between January 2010 and December 2021. OUTCOME MEASURES: Frequency of new or progressed VCFs and subdistribution hazard ratios for potentially associated factors. METHODS: Patient and treatment characteristics were manually collected from the patients' electronic medical records. Computed tomography (CT) scans from before and up to 3 years after the start of radiation were used to score radiographic variables at baseline and at follow-up. Multivariable Fine and Gray competing risk analyses were performed to evaluate the diagnostic value of the SINS score to predict the postradiation VCF rate. RESULTS: A total of 127 patients with 427 eligible radiated vertebrae were included in this study. The mean age at radiation was 64 years, and 66.1% of them were male. At the start of radiation, 57 patients (44.9%) had at least one VCF. There were 89 preexisting VCFs (18.4% of 483 vertebrae). Overall, 39 of 127 patients (30.7%) reported new fractures (number of vertebrae (n)=12) or showed progression of existing fractures (n=36). This number represented 11.2% of all radiated vertebrae. Five of the 39 (12.8%) patients with new or worsened VCFs received an unplanned secondary treatment (augmentation [n=2] or open surgery [n=3]) within 3 years. Both the total SINS score (SHR 1.77; 95% confidence interval (CI) 1.54-2.03; p<.001) and categorical SINS score (SHR 10.83; 95% CI 4.20-27.94; p<.001) showed an independent association with higher rates of new or progressed VCFs in adjusted analyses. The use of bisphosphonates was independently associated with a lower rate of new or progressed VCFs (SHR 0.47 [95% CI 0.24-0.92; p=.027]). CONCLUSIONS: This study demonstrated that new or progressed VCFs occurred in 30.7% of patients within 3 years, in a total of 11.2% of vertebrae. The SINS score was found to be independently associated with the development or progression of VCFs and could thus be applied in MM for fracture prediction and possibly prevention.


Assuntos
Fraturas por Compressão , Mieloma Múltiplo , Fraturas da Coluna Vertebral , Humanos , Masculino , Feminino , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/epidemiologia , Fraturas da Coluna Vertebral/etiologia , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/epidemiologia , Fraturas por Compressão/etiologia , Mieloma Múltiplo/epidemiologia , Mieloma Múltiplo/radioterapia , Mieloma Múltiplo/complicações , Estudos de Coortes , Qualidade de Vida , Coluna Vertebral , Estudos Retrospectivos
13.
Neurosurgery ; 94(4): 797-804, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37902322

RESUMO

BACKGROUND AND OBJECTIVES: Vertebral compression fracture (VCF) is a common, but serious toxicity of spinal stereotactic body radiotherapy (SBRT). Several variables that place patients at high risk of VCF have previously been identified, including advanced Spinal Instability Neoplastic Score (SINS), a widely adopted clinical decision criterion to assess spinal instability. We examine the role of tumoral endplate (EP) disruption in the risk of VCF and attempt to incorporate it into a simple risk stratification system. METHODS: This study was a retrospective cohort study from a single institution. Demographic and treatment information was collected for patients who received spinal SBRT between 2013 and 2019. EP disruption was noted on pre-SBRT computed tomography scan. The primary end point of 1-year cumulative incidence of VCF was assessed on follow-up MRI and computed tomography scans at 3-month intervals after treatment. RESULTS: A total of 111 patients were included. The median follow-up was 18 months. Approximately 48 patients (43%) had at least one EP disruption. Twenty patients (18%) experienced a VCF at a median of 5.2 months from SBRT. Patients with at least one EP disruption were more likely to experience VCF than those with no EP disruption (29% vs 6%, P < .001). A nomogram was created using the variables of EP disruption, a SINS of ≥7, and adverse histology. Patients were stratified into groups at low and high risk of VCF, which were associated with 2% and 38% risk of VCF ( P < .001). CONCLUSION: EP disruption is a novel risk factor for VCF in patients who will undergo spinal SBRT. A simple nomogram incorporating EP disruption, adverse histology, and SINS score is effective for quickly assessing risk of VCF. These data require validation in prospective studies and could be helpful in counseling patients regarding VCF risk and referring for prophylactic interventions in high-risk populations.


Assuntos
Fraturas por Compressão , Radiocirurgia , Fraturas da Coluna Vertebral , Neoplasias da Coluna Vertebral , Humanos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/epidemiologia , Fraturas da Coluna Vertebral/etiologia , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/etiologia , Fraturas por Compressão/epidemiologia , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Estudos Prospectivos , Estudos Retrospectivos , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/patologia
14.
J Vasc Interv Radiol ; 35(1): 59-68, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37797739

RESUMO

PURPOSE: To evaluate of the rate of and risks for progression toward collapse in vertebral metastases (VMs) treated with percutaneous vertebroplasty (PV). MATERIALS AND METHODS: A total of 151 PVs were performed in 81 patients with vertebral metastases and were retrospectively analyzed. Follow-up imaging was performed at 12 months to measure vertebral body height and to report vertebral collapse at the level of the treated vertebrae. Vertebral characteristics (spine instability neoplastic score [SINS], number of lysed cortices, and prior radiotherapy) and procedural parameters (Saliou score, cortical contact with cement, and intradiscal cement leakage) were compared between the group of patients with and without collapse of the treated vertebrae. RESULTS: Of the vertebrae treated with PV, 41 of 151 (27%) progressed toward collapse. Vertebral collapse was influenced by a high SINS (odds ratio [OR] = 1.27, P = .004), SINS value > 9 (OR = 2.96, P = .004), intradiscal cement leakage (OR = 2.18, P = .048), pre-existing spinal deformity (OR = 2.65, P = .020), and pre-existing vertebral fracture (OR = 3.93, P = .045). A high Saliou score (OR = 0.82, P = .011), more than 3 cortices in contact with the cement (OR = 0.38, P = .014), and preserved spinal alignment (OR = 0.38, P = .020) were associated with a lower incidence of collapse. CONCLUSIONS: Rate of vertebral collapse despite PV was influenced by vertebra-specific characteristics and by cement injection quality. Vertebrae with a SINS of ≤9 and with homogeneous cement filling had a lower incidence of collapse.


Assuntos
Fraturas por Compressão , Fraturas Espontâneas , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Vertebroplastia , Humanos , Vertebroplastia/efeitos adversos , Estudos Retrospectivos , Coluna Vertebral/cirurgia , Fraturas Espontâneas/etiologia , Cimentos Ósseos/efeitos adversos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Fatores de Risco , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/cirurgia , Fraturas por Osteoporose/terapia , Resultado do Tratamento
15.
Jt Dis Relat Surg ; 35(1): 218-230, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38108184

RESUMO

OBJECTIVES: The study aimed to compare the efficacy and safety of percutaneous kyphoplasty (PKP) and vertebral body stenting (VBS) in the treatment of osteoporotic vertebral compression fractures (OVCFs) and evaluate the clinical efficacy, Cobb angle correction, and cement leakage associated with both methods for OVCFs. PATIENTS AND METHODS: A systematic search was conducted in PubMed, EMBASE, Cochrane Library, Medline, China National Knowledge, and Wanfang Data for clinical studies comparing VBS with PKP for OVCF up to May 2023. The meta-analysis was performed using Review Manager 5.3, with a focus on evaluating clinical and radiologic outcomes. RESULTS: A total of eight eligible clinical studies were included in this meta-analysis. In terms of clinical outcomes, VBS was found to have a longer surgical time compared to PKP (standard mean difference [SMD]=1.06 min; 95% confidence interval [CI]: 0.20, 1.92; p=0.02). However, VBS demonstrated comparable blood loss to PKP (SMD =0.00 mL; 95% CI: -0.45, 0.45; p=0.99). Additionally, VBS showed slight superiority in alleviating back pain as measured by the Visual Analog Scale (VAS) (SMD=-0.38; 95% CI: -0.63, -0.12; p=0.004), as well as in improving functional disability based on the Oswestry Disability Index (ODI) (SMD= -0.28; 95% CI: -0.54, -0.03; p=0.03). Radiographically, VBS achieved better Cobb angle correction compared to PKP (SMD= -1.00; 95% CI: -1.48, -0.51; p<0.0001), while there was no significant difference in cement leakage between VBS and PKP (odds ratio=0.81; 95% CI: 0.21, 3.14; p=0.76). CONCLUSION: The findings suggest that VBS has a comparable clinical outcome to PKP based on operation time, intraoperative blood loss, VAS, and ODI. Furthermore, VBS showed slightly better maintenance of Cobb angle correction, whereas VBS did not demonstrate a significant advantage over PKP in terms of cement leakage.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Humanos , Cifoplastia/métodos , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/cirurgia , Fraturas por Compressão/tratamento farmacológico , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Fraturas da Coluna Vertebral/tratamento farmacológico , Corpo Vertebral , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/cirurgia , Cimentos Ósseos/uso terapêutico
16.
Radiography (Lond) ; 30(1): 353-358, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38134628

RESUMO

INTRODUCTION: Accurately distinguishing between benign and malignant vertebral compression fractures is crucial for clinical management. This study evaluated the predictive accuracy of diffusion-weighted imaging (DWI) in differentiating the cause of vertebral fractures using MRI. METHODS: A longitudinal cross-over study was conducted at Jinnah Postgraduate Medical Centre (JPMC) Karachi from July 2018 to January 2021. Patients with vertebral compression fractures underwent T1-weighted, T2-weighted, and DWI imaging with ADC mapping on a 1.5 T MRI scanner. Imaging findings were compared with histopathologic results and clinical follow-up. Sensitivity, specificity, and ROC curve analyses were performed. RESULTS: The study enrolled 303 patients with a mean age of 43.6 ± 10.9 years, of whom 118 were male. DWI demonstrated high accuracy in predicting the cause of vertebral compression fractures, with a sensitivity of 96.2 %, a specificity of 76.2 %, and an area under the ROC curve of 0.857. The optimal ADC cut-off value was 0.82 × 10˄-3 mm˄2/s, which yielded a positive predictive value of 79.7 % and a negative predictive value of 95.4 %. CONCLUSIONS: DWI is a safe and non-invasive imaging modality with excellent predictive accuracy in differentiating between benign and malignant vertebral compression fractures. Iso- or hypointensity of collapsed vertebral bodies on DWI suggests a benign lesion, while T2-weighted hyperintensity is highly indicative of malignancy. Low signal on ADC is also highly indicative of malignant vertebral fractures. Incorporating DWI improves accuracy in assessing vertebral lesions, especially when standard sequences are inconclusive. IMPLICATIONS FOR PRACTICE: DWI revolutionizes vertebral compression fracture diagnosis, distinguishing between benign and malignant cases. This precision guides treatment decisions, minimizing the necessity for invasive procedures like biopsy. As a safe and reliable imaging method, DWI elevates patient care, ensuring accurate diagnostics and improved outcomes.


Assuntos
Fraturas por Compressão , Fraturas da Coluna Vertebral , Neoplasias da Coluna Vertebral , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/etiologia , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/etiologia , Estudos Cross-Over , Neoplasias da Coluna Vertebral/complicações , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/efeitos adversos
17.
J Orthop Surg Res ; 18(1): 914, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38037128

RESUMO

BACKGROUND: Postmenopausal women face a heightened risk of developing new vertebral compression fractures (NVCFs) following percutaneous kyphoplasty (PKP) for osteoporotic vertebral compression fractures (OVCFs). This study aimed to develop and validate a visual nomogram model capable of accurately predicting NVCF occurrence post-PKP to optimize treatment strategies and minimize occurrence. METHODS: This retrospective study included postmenopausal women diagnosed with OVCF who underwent PKP at the Affiliated Hospital of Shandong University of Traditional Chinese Medicine between January 2016 and January 2021. Patient data, including basic information, surgical details, imaging records, and laboratory findings, were collected. The patients were categorized into two groups based on NVCF occurrence within 2 years post-PKP: the NVCF group and the non-NVCF group. Following the utilization of least absolute shrinkage and selection operator (LASSO) regression for feature selection, a nomogram was constructed. Model differentiation, calibration, and clinical applicability were evaluated using receiver operating characteristic (ROC), calibration, and decision (DCA) curve analyses. RESULTS: In total, 357 patients were included in the study. LASSO regression analysis indicated that cement leakage, poor cement diffusion, and endplate fracture were independent predictors of NVCF. The nomogram demonstrated excellent predictive accuracy and clinical applicability. CONCLUSIONS: This study used LASSO regression to identify three independent predictors of NVCF and developed a predictive model that could effectively predict NVCF occurrence in postmenopausal women. This simple prediction model can support medical decision-making and is feasible for clinical practice.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Humanos , Feminino , Cifoplastia/efeitos adversos , Cifoplastia/métodos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/etiologia , Fraturas da Coluna Vertebral/cirurgia , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/etiologia , Fraturas por Compressão/cirurgia , Estudos Retrospectivos , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/etiologia , Fraturas por Osteoporose/cirurgia , Pós-Menopausa , Nomogramas , Resultado do Tratamento , Cimentos Ósseos/uso terapêutico
18.
J Orthop Surg Res ; 18(1): 887, 2023 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-37993875

RESUMO

PURPOSE: To assess the safety and efficacy of the extra-facet puncture technique applied in unilateral percutaneous vertebroplasty (PVP) for treating osteoporotic vertebral compression fractures. METHODS: Demographics (age, gender, body mass index and underlying diseases) were recorded for analyzing. Visual analog scale (VAS) and Oswestry Disability Index (ODI) scores as well as their corresponding minimal clinically important difference (MCID) were used to evaluate clinical outcomes. The segmental kyphotic angle, the vertebral compression ratio and bone cement distribution pattern were evaluated by the plain radiographs. The facet joint violation (FJV) was defined by the postoperative computed tomography scan. Binary logistic regression analysis was performed to investigate relationships between multiple risk factors and residual back pain. RESULTS: VAS and ODI scores in both traditional puncture group and extra-facet puncture group were significantly decreased after PVP surgery (p < 0.05). However, no significant difference was observed between the two groups according to VAS and ODI scores. The proportion of patients achieving MCID of VAS and ODI scores was higher in extra-facet puncture group as compared to traditional puncture group within a month (p < 0.05). Finally, multivariate logistic regression analysis showed that FJV (odds ratio 16.38, p < 0.001) and unilateral bone cement distribution (OR 5.576, p = 0.020) were significant predictors of residual back pain after PVP surgery. CONCLUSIONS: Extra-facet puncture percutaneous vertebroplasty can decrease the risk of FJV and it also has the advantage of more satisfied bone cement distribution.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Vertebroplastia , Humanos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Fraturas da Coluna Vertebral/tratamento farmacológico , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/cirurgia , Fraturas por Compressão/tratamento farmacológico , Vertebroplastia/métodos , Cimentos Ósseos/uso terapêutico , Resultado do Tratamento , Estudos Retrospectivos , Dor nas Costas , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/cirurgia , Fraturas por Osteoporose/tratamento farmacológico , Cifoplastia/métodos
19.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 37(10): 1246-1252, 2023 Oct 15.
Artigo em Chinês | MEDLINE | ID: mdl-37848320

RESUMO

Objective: To investigate the effectiveness of sagittal top compression reduction technique in the treatment of thoracolumbar vertebral fractures. Methods: A retrospective analysis was conducted on the clinical data of 59 patients with thoracolumbar vertebral fractures who met the selection criteria and were admitted between November 2018 and January 2022. Among them, 34 patients were treated with sagittal top compression reduction technique (top pressure group), and 25 patients were treated with traditional reduction technique (traditional group). There was no significant difference in baseline data between the two groups ( P>0.05), including gender, age, fracture segment, cause of injury, AO classification of thoracolumbar vertebral fractures, thoracolumbar injury classification and severity (TLICS) score, American Spinal Injury Association (ASIA) grading, surgical approach, preoperative vertebral body index, height ratio of the anterior margin of injured vertebra, injured vertebra angle, segmental kyphosis angle, visual analogue scale (VAS) score, and Oswestry disability index (ODI). The operation time, intraoperative blood loss, and incidence of complications between the two groups were recorded and compared. After operation, VAS score and ODI were used to evaluate effectiveness, and X-ray and CT examinations were performed to measure imaging indicators such as vertebral body index, height ratio of the anterior margin of injured vertebra, injured vertebra angle, and segmental kyphosis angle. Results: There was no significant difference in operation time and intraoperative blood loss between the two groups ( P>0.05). No complication such as dural sac, nerve root, or vascular injury was found during operation, and all incisions healed by first intention. Patients in both groups were followed up 6-48 months, with an average of 20.6 months. No loosening, breakage, or failure of internal fixation occurred during follow-up. The imaging indicators, VAS score, and ODI of the two groups significantly improved at 1 week and last follow-up when compared to preoperative ones ( P<0.05). At last follow-up, the VAS score and ODI further significantly improved when compared to 1 week after operation ( P<0.05). At 1 week after operation and last follow-up, the vertebral body index, segmental kyphosis angle, injured vertebra angle, and ODI in the top pressure group were significantly better than those in the traditional group ( P<0.05). There was no significant difference in VAS score and height ratio of the anterior margin of injured vertebra between the two groups at 1 week after operation ( P>0.05), but the two indicators in the top pressure group were significantly better than those in the traditional group at last follow-up ( P<0.05). Conclusion: The treatment of thoracolumbar vertebral fractures with sagittal top compression reduction technique can significantly improve the quality of vertebral reduction, and is superior to traditional reduction techniques in relieving pain and improving spinal function.


Assuntos
Fraturas por Compressão , Cifose , Parafusos Pediculares , Fraturas da Coluna Vertebral , Humanos , Vértebras Torácicas/cirurgia , Vértebras Torácicas/lesões , Vértebras Lombares/cirurgia , Vértebras Lombares/lesões , Estudos Retrospectivos , Perda Sanguínea Cirúrgica , Resultado do Tratamento , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Fixação Interna de Fraturas , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/cirurgia
20.
Acta Neurochir (Wien) ; 165(12): 3975-3978, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37816917

RESUMO

BACKGROUND: To report the feasibility and safety of C1 kyphoplasty using the Cirq® robotic assistance coupled to the AIRO® intraoperative computed tomography (iCT)-scan and BrainLab® navigation system. METHODS: A 47-year-old woman with C1 osteolytic lesion responsible of intractable left-sided suboccipital pain was admitted. She underwent a percutaneous kyphoplasty of left lateral mass of C1 using Cirq® robotic assistance. She reported postoperative substantial pain relief. CT scan showed adequate filling of the osteolytic lesion without obvious leakage of cement. CONCLUSION: Percutaneous kyphoplasty of C1 using Cirq® robotic assistance is a safe and effective alternative in selected patients with C1 lateral mass metastasis.


Assuntos
Fraturas por Compressão , Cifoplastia , Dor Intratável , Procedimentos Cirúrgicos Robóticos , Fraturas da Coluna Vertebral , Feminino , Humanos , Pessoa de Meia-Idade , Cifoplastia/métodos , Estudos de Viabilidade , Cimentos Ósseos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA