Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biomed Chromatogr ; 38(7): e5871, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38599686

RESUMO

We report the development and the validation of a sensitive liquid chromatography-mass spectrometry (LC-MS/MS) method for mometasone furoate (MF) analysis in human plasma. Plasma samples were processed through liquid-liquid extraction and analyzed using LC-MS/MS operating in positive mode using multiple reaction monitoring of transitions m/z 520.9 â†’ 355.0 and m/z 525.8 â†’ 355.0 for MF and the internal standard (IS), respectively. Separation was achieved at 1.0 mL/min on a C18 column using a gradient elution of mobile phase of 0.05% ammonia in water (phase A) and acetonitrile (phase B). The assay range was 0.250-100 pg/mL and proved to be accurate and precise MF. Normalized recoveries were consistent and reproducible with a coefficient of variation (CV%) value of 6.0. The CV (%) of the IS normalized matrix factor was not observed in normal, lipemic, and hemolyzed plasmas. Dilutions of 1:10 were accurately quantified. A cycle of three freeze and thaw and stabilities at room temperature and on the autosampler were demonstrated. In addition, MF in the presence of indacaterol and glycopyrronium was proven to be stable at -70°C for at least 157 days. The present method was successfully applied to quantify MF in patients receiving MF, indacaterol, and glycopyrronium as a fixed-dose combination.


Assuntos
Furoato de Mometasona , Espectrometria de Massas em Tandem , Humanos , Furoato de Mometasona/sangue , Furoato de Mometasona/farmacocinética , Furoato de Mometasona/química , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes , Cromatografia Líquida/métodos , Modelos Lineares , Sensibilidade e Especificidade , Estabilidade de Medicamentos , Extração Líquido-Líquido/métodos , Limite de Detecção , Espectrometria de Massa com Cromatografia Líquida
2.
J Chromatogr Sci ; 57(10): 867-873, 2020 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-31602483

RESUMO

Nadifloxacin, mometasone furoate and miconazole nitrate are formulated together as a topical antifungal dosage form. In this work, a reversed-phase ultra-performance liquid chromatographic method coupled with a diode array detector (RP-UPLC-DAD) was developed and validated to determine nadifloxacin, mometasone furoate and miconazole nitrate simultaneously in their bulk powder, in pharmaceutical preparation and in spiked human plasma samples. Separation was achieved on an ACQUITY UPLC C18 column of 2.2 µm particle size (2.1 × 100 mm) via isocratic elution using a mobile phase consisting of methanol, acetonitrile and water with ratio (50:20:30; v/v/v) and 0.1 g ammonium acetate, then pH was adjusted to (7.00) using acetic acid, flow rate 0.6 mL/min, temperature 30°C and UV detection at 220 nm. The method is linear in a range from 5 to 400 µg/mL for both nadifloxacin and miconazole nitrate and from 20 to 500 µg/mL for mometasone furoate. The method was validated according to the ICH guidelines then applied successfully to determine the mentioned drugs in their pharmaceutical preparation and spiked human plasma samples. For plasma samples, the results showed that the method can determine nadifloxacin, mometasone furoate and miconazole nitrate in human plasma samples with high accuracy and precision.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Fluoroquinolonas/análise , Miconazol/análise , Furoato de Mometasona/análise , Quinolizinas/análise , Cromatografia de Fase Reversa , Fluoroquinolonas/sangue , Fluoroquinolonas/química , Humanos , Limite de Detecção , Modelos Lineares , Miconazol/sangue , Miconazol/química , Furoato de Mometasona/sangue , Furoato de Mometasona/química , Quinolizinas/sangue , Quinolizinas/química , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA