Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 166
Filtrar
1.
J Chromatogr A ; 1726: 464946, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38744185

RESUMO

On-line coupled high performance liquid chromatography-gas chromatography-flame ionisation detection (HPLC-GC-FID) was used to compare the effect of hydrogen, helium and nitrogen as carrier gases on the chromatographic characteristics for the quantification of mineral oil hydrocarbon (MOH) traces in food related matrices. After optimisation of chromatographic parameters nitrogen carrier gas exhibited characteristics equivalent to hydrogen and helium regarding requirements set by current guidelines and standardisation such as linear range, quantification limit and carry over. Though nitrogen expectedly led to greater peak widths, all required separations of standard compounds were sufficient and humps of saturated mineral oil hydrocarbons (MOSH) and aromatic mineral oil hydrocarbons (MOAH) were appropriate to enable quantitation similar to situations where hydrogen or helium had been used. Slightly increased peak widths of individual hump components did not affect shapes and widths of the MOSH and MOAH humps were not significantly affected by the use of nitrogen as carrier gas. Notably, nitrogen carrier gas led to less solvent peak tailing and smaller baseline offset. Overall, nitrogen may be regarded as viable alternative to hydrogen or helium and may even extend the range of quantifiable compounds to highly volatile hydrocarbon eluting directly after the solvent peak.


Assuntos
Hidrocarbonetos , Óleo Mineral , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Gasosa/métodos , Óleo Mineral/química , Óleo Mineral/análise , Hidrocarbonetos/análise , Nitrogênio/análise , Hélio/química , Hidrogênio/química , Ionização de Chama/métodos , Gases/química
2.
J Chromatogr A ; 1722: 464869, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38604057

RESUMO

Hydrodynamics, efficiency, and loading capacity of two semi-packed columns with different cross sections (NANO 315 µm x 18 µm; CAP 1000 µm x 28 µm) and similar pillar diameter and pillar-pillar distance (respectively 5 µm and 2.5 µm) have been compared in high-pressure gas chromatography. A flow prediction tool has been first designed to determine pressure variations and hold-up time across the chromatographic system taking into account the rectangular geometry of the ducts into the semi-packed columns. Intrinsic values of Height Equivalent to Theoretical Plate were determined for NANO and CAP columns using helium as carrier gas and similar values have been obtained (30 µm) for the two columns. Loading capacity of semi-packed columns were determined for decane at 70 °C using helium, and the highest value was obtained from CAP column (larger cross section and stationary phase content). Finally, significant HETP improvement (down to 15 µm) and peak shape were observed when carbon dioxide was used as carrier gas, suggesting mobile phase adsorption on stationary phase in high pressure conditions.


Assuntos
Hélio , Pressão , Cromatografia Gasosa/métodos , Cromatografia Gasosa/instrumentação , Hélio/química , Hidrodinâmica , Dióxido de Carbono/química , Adsorção
3.
J Chromatogr A ; 1697: 463989, 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37075497

RESUMO

Gas chromatography mass spectrometry (GC-MS) is a commonly used method for organic geochemistry for both academic research and applications such as petroleum analysis. Gas chromatography requires a carrier gas, which needs to be both volatile and stable and in most organic geochemical applications helium or hydrogen have been used, with helium predominating for gas chromatography mass spectrometry. Helium, however, is becoming an increasingly scarce resource and is not sustainable. Hydrogen is the most commonly considered alternative carrier gas to helium but has characteristics that in certain respects make its use less practical, foremost is that hydrogen is flammable and explosive. But as hydrogen is increasingly used as a fuel, higher demand may also make its use less desirable. Here we show that nitrogen can be used for the GC-MS analysis of fossil lipid biomarkers. Using nitrogen, chromatographic separation of isomers and homologues can be achieved, but sensitivity is orders of magnitude less than for helium. It is reasonable to use nitrogen as a carrier gas in applications where low levels of detection are not needed, such as the characterization of samples of crude oil or foodstuffs, or potentially as part of a gas-mixture seeking to reduce helium-demand but maintain a level of chromatographic separation sufficient to support proxy-based characterizations of petroleum.


Assuntos
Nitrogênio , Petróleo , Cromatografia Gasosa-Espectrometria de Massas/métodos , Nitrogênio/química , Petróleo/análise , Hélio/química , Hidrogênio/química
4.
Phys Med ; 109: 102587, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37087865

RESUMO

PURPOSE: To evaluate the applicability of microdosimetric kinetic model (MKM) to helium-ion therapy by forming a spread-out Bragg peak (SOBP) of a helium-ion beam using the MKM developed for carbon-ion radiotherapy and confirming the predictions in biological experiments. METHODS: Using a ridge filter, a 90-mm wide SOBP for a 210 MeV/u helium-ion beam was created in a broad beam delivery system. The ridge filter was designed such that a uniform biological response was achieved with a cell survival rate of 7% over the SOBP region. Biological experiments were then performed using the SOBP beam in a human salivary gland (HSG) cell line to measure the cell survival rates. RESULTS: The biological responses were uniform in the SOBP region, as expected by the MKM; however, the mean of the measured cell survival rates was (11.2 ± 0.6) % in the SOBP region, which was 60% higher than the designed rate. When investigating the biological parameters of the HSG cell line used in the experiments, we found that they were altered slightly from the MKM parameters used for carbon-ion radiotherapy. The new ß parameter reproduced the measured survival rates within 6.5% in the SOBP region. CONCLUSION: We produced biologically uniform SOBP using MKM for carbon-ion radiotherapy. The measured survival rates in the SOBP region were higher than expected, and the survival rates were reproduced by modifying the MKM parameter. This study was limited to one SOBP, and further investigations are required to prove that MKM is generally applicable to helium-ion radiotherapy.


Assuntos
Modelos Químicos , Hélio/química , Íons/química , Dosimetria Fotográfica , Cinética
5.
Molecules ; 25(20)2020 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-33066650

RESUMO

44Sc has favorable properties for cancer diagnosis using Positron Emission Tomography (PET) making it a promising candidate for application in nuclear medicine. The implementation of its production with existing compact medical cyclotrons would mean the next essential milestone in the development of this radionuclide. While the production and application of 44Sc has been comprehensively investigated, the development of specific targetry and irradiation methods is of paramount importance. As a result, the target was optimized for the 44Ca(p,n)44Sc nuclear reaction using CaO instead of CaCO3, ensuring decrease in target radioactive degassing during irradiation and increased radionuclidic yield. Irradiations were performed at the research cyclotron at the Paul Scherrer Institute (~11 MeV, 50 µA, 90 min) and the medical cyclotron at the University of Bern (~13 MeV, 10 µA, 240 min), with yields varying from 200 MBq to 16 GBq. The development of targetry, chemical separation as well as the practical issues and implications of irradiations, are analyzed and discussed. As a proof-of-concept study, the 44Sc produced at the medical cyclotron was used for a preclinical study using a previously developed albumin-binding prostate-specific membrane antigen (PSMA) ligand. This work demonstrates the feasibility to produce 44Sc with high yields and radionuclidic purity using a medical cyclotron, equipped with a commercial solid target station.


Assuntos
Ciclotrons , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos , Escândio , Albuminas/metabolismo , Animais , Antígenos de Superfície , Compostos de Cálcio/química , Resinas de Troca de Cátion/química , Desenho de Equipamento , Feminino , Glutamato Carboxipeptidase II , Hélio/química , Humanos , Marcação por Isótopo/métodos , Camundongos Nus , Neoplasias Experimentais/diagnóstico por imagem , Óxidos/química , Estudo de Prova de Conceito , Radioisótopos/química , Compostos Radiofarmacêuticos/química , Escândio/química , Ensaios Antitumorais Modelo de Xenoenxerto
6.
Molecules ; 25(15)2020 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-32751962

RESUMO

Water radical cations, (H2O)n+•, are of great research interest in both fundamental and applied sciences. Fundamental studies of water radical reactions are important to better understand the mechanisms of natural processes, such as proton transfer in aqueous solutions, the formation of hydrogen bonds and DNA damage, as well as for the discovery of new gas-phase reactions and products. In applied science, the interest in water radicals is prompted by their potential in radiobiology and as a source of primary ions for selective and sensitive chemical ionization. However, in contrast to protonated water clusters, (H2O)nH+, which are relatively easy to generate and isolate in experiments, the generation and isolation of radical water clusters, (H2O)n+•, is tremendously difficult due to their ultra-high reactivity. This review focuses on the current knowledge and unknowns regarding (H2O)n+• species, including the methods and mechanisms of their formation, structure and chemical properties.


Assuntos
Cátions/química , Água/química , Pressão Atmosférica , Deutério/química , Radicais Livres/química , Hélio/química , Ligação de Hidrogênio , Simulação de Dinâmica Molecular , Nitrogênio/química , Fótons , Prótons
7.
Biointerphases ; 15(3): 038501, 2020 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-32590901

RESUMO

Single protein imaging and understanding their interactions are of paramount importance to understand the life phenomena. Recently reported multiplex protein SIMS imaging methodology using metal-oxide nanoparticle conjugated antibodies can be extended to a single protein imaging methodology using He ion microscopy (HIM). It is proposed here that single protein can be imaged in the microscale and the nanoscale by the complementary use of SIMS and HIM.


Assuntos
Hélio/química , Imageamento Tridimensional , Microscopia , Proteínas/análise , Espectrometria de Massa de Íon Secundário , Linhagem Celular Tumoral , Humanos , Íons , Microscopia de Fluorescência
8.
Molecules ; 25(3)2020 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-31973084

RESUMO

Using methods of pulsed laser ablation from a silicon target in helium (He)-nitrogen (N2) gas mixtures maintained at reduced pressures (0.5-5 Torr), we fabricated substrate-supported silicon (Si) nanocrystal-based films exhibiting a strong photoluminescence (PL) emission, which depended on the He/N2 ratio. We show that, in the case of ablation in pure He gas, Si nanocrystals exhibit PL bands centered in the "red - near infrared" (maximum at 760 nm) and "green" (centered at 550 nm) spectral regions, which can be attributed to quantum-confined excitonic states in small Si nanocrystals and to local electronic states in amorphous silicon suboxide (a-SiOx) coating, respectively, while the addition of N2 leads to the generation of an intense "green-yellow" PL band centered at 580 nm. The origin of the latter band is attributed to a radiative recombination in amorphous oxynitride (a-SiNxOy) coating of Si nanocrystals. PL transients of Si nanocrystals with SiOx and a-SiNxOy coatings demonstrate nonexponential decays in the micro- and submicrosecond time scales with rates depending on nitrogen content in the mixture. After milling by ultrasound and dispersing in water, Si nanocrystals can be used as efficient non-toxic markers for bioimaging, while the observed spectral tailoring effect makes possible an adjustment of the PL emission of such markers to a concrete bioimaging task.


Assuntos
Hélio/química , Lasers , Medições Luminescentes , Nanopartículas/química , Nitrogênio/química , Silício/química , Nanopartículas/ultraestrutura , Pressão , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral Raman
9.
J Chromatogr A ; 1614: 460736, 2020 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-31831146

RESUMO

This article describes a new simultaneous method for the analysis of sulfur-type poisons, hydrocarbons and permanent gases affecting the productivity of the Ziegler Natta catalyst during the synthesis of polypropylene on an industrial scale in a fluidized-bed reactor. The identification was achieved employing a configuration of the seven-valve chromatographic system, with events at different times, allowing distribution of the sample through multiple columns, and finally reaching the helium ionization detectors of pulsed discharge, flame ionization and mass spectrometry. The results obtained show a good precision of the method used because the variability was less than 1.02% in area and 0.49% in retention time for short term precisión and longer term precision . The quantification of these species was successful after performing the calibration curve with the dynamic mixer showing an r2 higher than 0.9945 and excellent linearity. The lowest LOD value was 0.01 mg kg-1 for carbonyl sulphide, hydrogen sulfide, ethylmercaptan and propylmercaptan and the lowest LOQ was 0.03 mg kg-1 for hydrogen sulfide. The highest LOD and LOQ values were for oxygen and carbon dioxide with 0.40 and 0.93 mg kg-1 respectively. With this configuration, the correlation of data between the three detectors was simplified, having almost identical retention times for the analytes studied. The poisons detected and quantified in the samples were: hydrogen sulfide (0.1-0.5 mg kg-1), carbonyl sulphide (0.012-0.06 mg kg-1), carbon disulphide (0.04-0.22 mg kg-1), methylmercaptan (0.12-12.51 mg kg-1), ethylmercaptan (0.9-5.5 mg kg-1), carbon dioxide (0.10-3.0 mg kg-1), oxygen (0.55-6.1 mg kg-1), acetylene (0.15-3.5 mg kg-1) and methylacetylene (0.04-0.2 mg kg-1). The productivity losses were between 5 and 22%.


Assuntos
Cromatografia Gasosa , Ionização de Chama , Hélio/química , Espectrometria de Massas , Venenos/análise , Polipropilenos/síntese química , Calibragem , Catálise , Hidrocarbonetos/análise , Sulfeto de Hidrogênio/análise
10.
Anal Chem ; 91(18): 11827-11833, 2019 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-31429255

RESUMO

Methylation of arginine residues in proteins, an enzyme-mediated post-translational modification (PTM), is important for mRNA processing and transport and for the regulation of many protein-protein interactions. However, proteolytic peptides resulting from alternative sites of post-translational methylation have identical masses and cannot be readily separated by standard liquid chromatography-mass spectrometry. Unlike acetylation or phosphorylation, methylation of arginine does not strongly affect the charge states of peptide ions, multiple instances of methylation can occur on a single amino acid residue, and the relative mass of the modification is <1% that of the typical proteolytic peptide. High field asymmetric waveform ion mobility spectrometry (FAIMS) is an orthogonal separation method to liquid chromatography that can rapidly separate gaseous ions prior to detection by mass spectrometry. Here, we report that FAIMS can be used to separate arginine-methylated peptides that differ by the position of a single methyl group for both mono- and dimethylated variants. Although the resolution of separation for these arginine-methylated peptides improved with increasing amounts of helium in the FAIMS carrier gas as expected, we found that the site of methylation can strongly affect the dependence of the electric field used for ion transmission on the extent of helium in the carrier gas. Thus, certain isobaric peptides can be cotransmitted at high helium concentrations whereas lower concentrations can be used for successful separations of such peptide mixtures. The capability to rapidly resolve isobaric arginine-methylated peptides should be useful in the future for the detailed analysis of protein arginine methylation in biological samples.


Assuntos
Espectrometria de Massas/métodos , Proteínas Nucleares/química , Peptídeos/isolamento & purificação , Ribonucleoproteínas Nucleolares Pequenas/química , Proteínas de Saccharomyces cerevisiae/química , Arginina/análogos & derivados , Arginina/química , Arginina/metabolismo , Hélio/química , Espectrometria de Mobilidade Iônica/métodos , Metilação , Proteínas Nucleares/metabolismo , Peptídeos/química , Peptídeos/metabolismo , Processamento de Proteína Pós-Traducional , Sequências Repetitivas de Aminoácidos , Ribonucleoproteínas Nucleolares Pequenas/metabolismo , Proteínas de Saccharomyces cerevisiae/metabolismo
11.
Clin Biochem ; 73: 98-104, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31425671

RESUMO

Here we validate a GC, Flame Ionization Detection (GC-FID), liquid injection method using hydrogen as a carrier gas combining analysis of toxic volatile alcohols (VA): methanol, ethanol, isopropanol, acetone, as well as glycols, ethylene glycol (EG) and propylene glycol (PG), in a single method. METHODOLOGY: 200 µL of calibrator, QC, or patient specimen were deproteinized with 400 µL of acetonitrile containing internal standards (10 mmol/L N-propyl alcohol for VA and 2.5 mmol/L 1,2-butanediol for glycols). GC-FID analysis using hydrogen carrier gas and nitrogen makeup gas utilized an Agilent 7890 system equipped with Agilent 7683 liquid autosampler on a 30 m × 530 µm RTX-200 fused silica column. Method validation included repeatability, recovery, carryover, linearity, lower limit of quantification (LLOQ), accuracy, selectivity and measurement uncertainty. RESULTS: The 8.3 min from injection to injection reduced time of analysis by 45% over a previously reported method using Helium carrier gas with no loss in resolution. Within-run and Between-run variability were ≤1.4% and ≤6.8% respectively. Recovery was 100% within a 95% confidence interval. Carryover was negligible for all but EG. LLOQ was <1 mmol/L for all analytes. The upper range of linearity was 120 mmol/L for methanol, ethanol and isopropanol, 100 mmol/L for acetone and 50 mmol/L for EG. Analytes demonstrated acceptable accuracy and measurement uncertainty using College of American Pathologists (CAP) criteria. Toluene can cause a false positive EG, while benzene, xylene and 1,3 butanediol can cause false negative EG. CONCLUSIONS: Converting from Helium to Hydrogen carrier gas benefits patient care through a reduction in turnaround time and provides a cost savings to the laboratory.


Assuntos
Etilenoglicol/sangue , Álcoois Graxos/sangue , Hélio/química , Hidrogênio/química , Calibragem , Cromatografia Gasosa , Feminino , Ionização de Chama , Humanos , Masculino
12.
Sci Rep ; 9(1): 8671, 2019 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-31209329

RESUMO

Cold Atmospheric Plasma (CAP) is a novel promising tool developed in several biomedical applications such as cutaneous wound healing or skin cancer. Nevertheless, in vitro studies are lacking regarding to CAP effects on cellular actors involved in healthy skin healing and regarding to the mechanism of action. In this study, we investigated the effect of a 3 minutes exposure to CAP-Helium on human dermal fibroblasts and Adipose-derived Stromal Cells (ASC) obtained from the same tissue sample. We observed that CAP treatment did not induce cell death but lead to proliferation arrest with an increase in p53/p21 and DNA damages. Interestingly we showed that CAP treated dermal fibroblasts and ASC developed a senescence phenotype with p16 expression, characteristic morphological changes, Senescence-Associated ß-galactosidase expression and the secretion of pro-inflammatory cytokines defined as the Senescence-Associated Secretory Phenotype (SASP). Moreover this senescence phenotype is associated with a glycolytic switch and an increase in mitochondria content. Despite this senescence phenotype, cells kept in vitro functional properties like differentiation potential and immunomodulatory effects. To conclude, we demonstrated that two main skin cellular actors are resistant to cell death but develop a senescence phenotype while maintaining some functional characteristics after 3 minutes of CAP-Helium treatment in vitro.


Assuntos
Ciclo Celular/efeitos dos fármacos , Senescência Celular/efeitos dos fármacos , Fibroblastos/efeitos dos fármacos , Células-Tronco Mesenquimais/efeitos dos fármacos , Gases em Plasma/farmacologia , Tecido Adiposo/citologia , Tecido Adiposo/metabolismo , Ciclo Celular/genética , Senescência Celular/genética , Inibidor p16 de Quinase Dependente de Ciclina/genética , Inibidor p16 de Quinase Dependente de Ciclina/metabolismo , Inibidor de Quinase Dependente de Ciclina p21/genética , Inibidor de Quinase Dependente de Ciclina p21/metabolismo , Fibroblastos/citologia , Fibroblastos/metabolismo , Regulação da Expressão Gênica , Hélio/química , Humanos , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/metabolismo , Mitocôndrias/efeitos dos fármacos , Mitocôndrias/metabolismo , Cultura Primária de Células , Transdução de Sinais , Pele/citologia , Pele/metabolismo , Fatores de Tempo , Proteína Supressora de Tumor p53/genética , Proteína Supressora de Tumor p53/metabolismo
13.
Phys Med Biol ; 64(12): 125008, 2019 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-30870831

RESUMO

Ion computed tomography (iCT) represents a potential replacement for x-ray CT (xCT) in ion therapy treatment planning to reduce range uncertainties, inherent in the semi-empirical conversion of xCT information into relative stopping power (RSP). In this work, we aim to quantify the increase in dosimetric accuracy associated with using proton-, helium- and carbon-CT compared to conventional xCT for clinical scenarios in proton therapy. Three cases imaged with active beam-delivery using an ideal single-particle-tracking detector were investigated using FLUKA Monte-Carlo (MC) simulations. The RSP accuracy of the iCTs was evaluated against the ground truth at similar physical dose. Next, the resulting dosimetric accuracy was investigated by using the RSP images as a patient model in proton therapy treatment planning, in comparison to common uncertainties associated with xCT. Finally, changes in relative biological effectiveness (RBE) with iCT particle type/spectrum were investigated by incorporating the repair-misrepair-fixation (RMF) model into FLUKA, to enable first insights on the associated biological imaging dose. Helium-CT provided the lowest overall RSP error, whereas carbon-CT offered the highest accuracy for bone and proton-CT for soft tissue. For a single field, the average relative proton beam-range variation was -1.00%, +0.09%, -0.08% and -0.35% for xCT, proton-, helium- and carbon-CT, respectively. Using a 0.5%/0.5mm gamma-evaluation, all iCTs offered comparable accuracy with a better than 99% passing rate, compared to 83% for xCT. The RMF model predictions for RBE for cell death relative to a diagnostic xCT spectrum were 0.82-0.85, 0.85-0.89 and 0.97-1.03 for proton-, helium-, and carbon-CT, respectively. The corresponding RBE for DNA double-strand break induction was generally below one. iCT offers great clinical potential for proton therapy treatment planning by providing superior dose calculation accuracy as well as lower physical and potentially biological dose exposure compared to xCT. For the investigated dose level and ideal detector, proton-CT and helium-CT yielded the best performance.


Assuntos
Carbono/química , Hélio/química , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Eficiência Biológica Relativa , Tomografia/métodos , Quebras de DNA de Cadeia Dupla/efeitos da radiação , Humanos , Método de Monte Carlo , Radiobiologia , Radiometria
14.
Magn Reson Med ; 81(5): 2959-2971, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30515852

RESUMO

PURPOSE: To compare in vivo lung morphometry parameters derived from theoretical gas diffusion models, the cylinder model and stretched exponential model, in a range of acinar microstructural length scales encountered in healthy and diseased lungs with 3 He and 129 Xe diffusion-weighted MRI. METHODS: Three-dimensional multiple b-value 3 He and 129 Xe diffusion-weighted MRI was acquired with compressed sensing at 1.5 T from 51 and 31 subjects, respectively, including healthy volunteers, ex-smokers, idiopathic pulmonary fibrosis, and chronic obstructive pulmonary disease patients. For each subject, the stretched exponential model-derived mean diffusive length scale (LmD ) was calculated from the diffusion signal decay, and was compared with the cylinder model-derived mean chord length (Lm) and mean alveolar diameter (LAlv ) in order to determine the relationships among the different lung morphometry parameters. RESULTS: For both 3 He and 129 Xe diffusion-weighted MRI, the mean global LmD value was significantly related (P < .001) to Lm in a nonlinear power relationship, whereas the LAlv demonstrated excellent linear correlation (P < .001) with LmD . A mean bias of +1.0% and - 2.6% toward LmD was obtained for Bland-Altman analyses of 3 He and 129 Xe LmD and LAlv values, suggesting that the two morphometric parameters are equivalent measures of mean acinar dimensions. CONCLUSION: Within the experimental range of parameters considered here for both 3 He and 129 Xe, the stretched exponential model-derived LmD is related nonlinearly to cylinder model-derived Lm, and demonstrates excellent agreement with the cylinder model-derived LAlv .


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Hélio/química , Fibrose Pulmonar Idiopática/diagnóstico por imagem , Imageamento Tridimensional/métodos , Pulmão/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Isótopos de Xenônio/química , Algoritmos , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador/métodos , Modelos Lineares , Imageamento por Ressonância Magnética , Distribuição Normal , Estudos Retrospectivos
15.
Free Radic Biol Med ; 129: 537-547, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30355525

RESUMO

Sulfasalazine (SSZ) is a well-known anti-inflammatory drug and also an inhibitor of the cystine-glutamate antiporter that is known to reduce intracellular glutathione (GSH) level and increase cellular oxidative stress, indicating its anti-tumor potential. However, the combination of SSZ with other physical modalities remains unexplored. Here, the effects of SSZ on cold atmospheric helium plasma (He-CAP), which produces approximately 24 x higher concentration of hydroxyl radicals (. OH) compared to X-irradiation (IR) in aqueous solution, and on IR-induced apoptosis in human leukemia Molt-4 cells were studied to elucidate the mechanism of apoptosis enhancement. Both the Annexin V-FITC/PI and DNA fragmentation assay revealed that pre-treatment of cells with SSZ significantly enhanced He-CAP and IR-induced apoptosis. Similar enhancement was observed during the loss of mitochondrial membrane potential, intracellular Ca2+ ions, and mitochondria- and endoplasmic reticulum-related proteins. The concentration of intracellular reactive oxygen species (ROS) was much higher in He-CAP treated cells than in X-irradiated cells. On the other hand, strong enhancement of Fas expression and caspase-8 and -3 activities were only observed in X-irradiated cells. It might be possible that the higher concentration of intracellular and extracellular ROS suppressed caspase activities and Fas expression in He-CAP-treated cells. Notably, pretreating the cells with an antioxidant N-acetyl-L-cysteine (NAC) dramatically decreased apoptosis in cells treated by He-CAP, but not by IR. These results suggest that IR-induced apoptosis is due to specific and effective ROS distribution since intracellular ROS formation is marginal and the high production of ROS inside and outside of cells plays unique roles in He-CAP induced apoptosis. We conclude that our data provides efficacy and mechanistic insights for SSZ, which might be helpful for establishing SSZ as a future sensitizer in He-CAP or IR therapy for cancer.


Assuntos
Radical Hidroxila/metabolismo , Oxidantes/farmacologia , Gases em Plasma/farmacologia , Sulfassalazina/farmacologia , Linfócitos T/metabolismo , Acetilcisteína/farmacologia , Antioxidantes/farmacologia , Apoptose/efeitos dos fármacos , Apoptose/efeitos da radiação , Cálcio/metabolismo , Caspase 3/genética , Caspase 3/metabolismo , Caspase 8/genética , Caspase 8/metabolismo , Cátions Bivalentes , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos da radiação , Fragmentação do DNA/efeitos dos fármacos , Fragmentação do DNA/efeitos da radiação , Regulação da Expressão Gênica , Células HCT116 , Hélio/química , Humanos , Radical Hidroxila/agonistas , Potencial da Membrana Mitocondrial/efeitos dos fármacos , Potencial da Membrana Mitocondrial/efeitos da radiação , Mitocôndrias/efeitos dos fármacos , Mitocôndrias/metabolismo , Mitocôndrias/efeitos da radiação , Estresse Oxidativo , Transdução de Sinais , Sulfassalazina/antagonistas & inibidores , Linfócitos T/efeitos dos fármacos , Linfócitos T/patologia , Linfócitos T/efeitos da radiação , Raios X , Receptor fas/genética , Receptor fas/metabolismo
16.
PLoS One ; 13(10): e0205371, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30304050

RESUMO

Helium, a minor component of natural gas and radioactive minerals, is most commonly used as a carrier in gas chromatography-mass spectrometry (GC-MS). Its scarcity leads to limited availability and higher costs. In this experiment, hydrogen from a safe source of a hydrogen generator was tested as a substitutive carrier gas for the detection of adulterant in traditional Chinese medicine (TCM) and food supplements by GC-MS analysis. We found that the limits of detection (LODs) of using hydrogen were from 10 to 1000 µg/g. The levels of LODs tested among 170 drugs remain the same whether hydrogen or helium was used as a carrier gas with the exception of 7 drugs-benzbromarone, estradiol benzoate, bezafibrate, mefenamic acid, oxymetholone, piperidenafil and cetilistat. The real sample analysis results using hydrogen were as satisfactory as those using helium. In addition, the retention time was shortened after the chromatographic performance was optimized. In summary, it is worth considering hydrogen as a carrier gas due to its affordable costs, energy efficiency, carbon reduction and chromatographic advantages to detect adulterated drugs in TCM and dietary supplement using GC-MS.


Assuntos
Suplementos Nutricionais/análise , Contaminação de Medicamentos/prevenção & controle , Medicamentos de Ervas Chinesas/análise , Hidrogênio/química , Clorzoxazona/análise , Contaminação de Medicamentos/economia , Cromatografia Gasosa-Espectrometria de Massas/métodos , Hélio/química , Hélio/economia , Humanos , Hidrogênio/economia , Limite de Detecção , Oximetolona/análise , Pirimidinonas/análise , Citrato de Sildenafila/análise , Sulfonas/análise
17.
J Magn Reson ; 292: 90-98, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29705031

RESUMO

Hyperpolarized 3He gas allows the air spaces of the lungs to be imaged via MRI. Imaging of restricted diffusion is addressed here, which allows the microstructure of the lung to be characterized through the physical restrictions to gas diffusion presented by airway and alveolar walls in the lung. Measurements of the apparent diffusion coefficient (ADC) of 3He at time scales of milliseconds and seconds are compared; measurement of acinar airway sizes by determination of the microscopic anisotropy of diffusion is discussed. This is where Dr. JJH Ackerman's influence was greatest in aiding the formation of the Washington University 3He group, involving early a combination of physicists, radiologists, and surgeons, as the first applications of 3He ADC were to COPD and its destruction/modification of lung microstructure via emphysema. The sensitivity of the method to early COPD is demonstrated, as is its validation by direct comparison to histology. More recently the method has been used broadly in adult and pediatric obstructive lung diseases, from severe asthma to cystic fibrosis to bronchopulmonary dysplasia, a result of premature birth. These applications of the technique are discussed briefly.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Hélio , Pulmão/diagnóstico por imagem , Adulto , Difusão , Hélio/química , Humanos , Lactente , Recém-Nascido , Pneumopatias Obstrutivas/congênito , Pneumopatias Obstrutivas/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Isótopos de Xenônio
18.
Phys Med Biol ; 62(19): 7569-7597, 2017 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-28895552

RESUMO

Ionization cluster size distributions produced in the sensitive volume of an ion-counting wall-less nanodosimeter by monoenergetic carbon ions with energies between 45 MeV and 150 MeV were measured at the TANDEM-ALPI ion accelerator facility complex of the LNL-INFN in Legnaro. Those produced by monoenergetic helium ions with energies between 2 MeV and 20 MeV were measured at the accelerator facilities of PTB and with a 241Am alpha particle source. C3H8 was used as the target gas. The ionization cluster size distributions were measured in narrow beam geometry with the primary beam passing the target volume at specified distances from its centre, and in broad beam geometry with a fan-like primary beam. By applying a suitable drift time window, the effective size of the target volume was adjusted to match the size of a DNA segment. The measured data were compared with the results of simulations obtained with the PTB Monte Carlo code PTra. Before the comparison, the simulated cluster size distributions were corrected with respect to the background of additional ionizations produced in the transport system of the ionized target gas molecules. Measured and simulated characteristics of the particle track structure are in good agreement for both types of primary particles and for both types of the irradiation geometry. As the range in tissue of the ions investigated is within the typical extension of a spread-out Bragg peak, these data are useful for benchmarking not only 'general purpose' track structure simulation codes, but also treatment planning codes used in hadron therapy. Additionally, these data sets may serve as a data base for codes modelling the induction of radiation damages at the DNA-level as they almost completely characterize the ionization component of the nanometric track structure.


Assuntos
Partículas alfa , Carbono/química , Hélio/química , Radiometria/instrumentação , Radiometria/métodos , Simulação por Computador , Método de Monte Carlo , Fenômenos Físicos
19.
J Phys Chem A ; 121(40): 7768-7777, 2017 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-28910102

RESUMO

Collision cross section (Ω) values of gas-phase ions of proteins and protein complexes are used to probe the structures of the corresponding species in solution. Ions of many proteins exhibit increasing Ω-values with increasing charge state but most Ω-values calculated for protein ions have used simple collision models that do not explicitly account for charge. Here we use a combination of ion mobility mass spectrometry experiments with helium gas and trajectory method calculations to characterize the extents to which increases in experimental Ω-values with increasing charge state may be attributed to increased momentum transfer concomitant with enhanced long-range interactions between the protein ion and helium atoms. Ubiquitin and C-to-N terminally linked diubiquitin ions generated from different solution conditions exhibit more than a 2-fold increase in Ω with increasing charge state. For native and energy-relaxed models of the proteins and most methods for distributing charge, Ω-values calculated using the trajectory method increase by less than 1% over the range of charge states observed from typical solution conditions used for native mass spectrometry. However, the calculated Ω-values increase by 10% to 15% over the full range of charge states observed from all solution conditions. Therefore, contributions from enhanced ion-induced dipole interactions with increasing charge state are significant but without additional structural changes can account for only a fraction of the increase in Ω observed experimentally. On the basis of these results, we suggest guidelines for calculating Ω-values in the context of applications in biophysics and structural biology.


Assuntos
Álcool Desidrogenase/química , Hélio/química , Ubiquitina/química , Ubiquitinas/química , Íons , Espectrometria de Massas , Modelos Químicos , Conformação Proteica
20.
Surg Technol Int ; 30: 19-24, 2017 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-28693047

RESUMO

OBJECTIVE: To evaluate tissue effect of J-Plasma® (Bovie Medical Corporation, Clearwater, Florida) in porcine liver, kidney, muscle, ovarian, and uterine tissue blocks. DESIGN: Prospective study utilizing porcine tissue blocks to evaluate the thermal spread of J-Plasma® device on liver, kidney, muscle, ovarian, and uterine tissue at various power settings, gas flow, and exposure times. MATERIALS AND METHODS: J-Plasma® helium was used in porcine liver, kidney, and muscle tissue at 20%, 50%, and 100% power, and 1 L/min, 3 L/min, and 5 L/min gas flow at one, five, and 10-second intervals. J-Plasma® was then used in ovarian and uterine tissue at maximum power and gas flow settings in intervals of one, five, 10, and 30 seconds. Histologic evaluation of each tissue was then performed to measure thermal spread. RESULTS: Regardless of tissue type, increased power setting, gas flow rate, and exposure time correlated with greater depth of thermal spread in liver, kidney, and muscle tissue. J-Plasma® did not exceed 2 mm thermal spread on liver, kidney, muscle, ovarian, and uterine tissue, even at a maximum setting of 100% power and 5 L/min gas flow after five seconds. Prolonged exposure to J-Plasma® of up to 30 seconds resulted in increased length and width of thermal spread of up to 12 mm, but did not result in significantly increased depth at 2.84 mm. CONCLUSIONS: The J-Plasma® helium device has minimal lateral and depth of thermal spread in a variety of tissue types and can likely be used for a multitude of gynecologic surgical procedures. However, further studies are needed to demonstrate device safety in a clinical setting.


Assuntos
Eletrocirurgia/métodos , Temperatura Alta , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Modelos Biológicos , Gases em Plasma/química , Animais , Eletrocirurgia/efeitos adversos , Eletrocirurgia/instrumentação , Desenho de Equipamento , Feminino , Hélio/química , Rim/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Ovário/patologia , Ovário/cirurgia , Estudos Prospectivos , Suínos , Útero/patologia , Útero/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA