Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Water Res ; 245: 120624, 2023 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-37717329

RESUMO

Disinfection by-products (DBPs) with significant teratogenic and carcinogenic properties have become a growing concern among the public. As an efficient and environmentally friendly technology, non-thermal plasma offers potential for removing emerging micro-pollutants. In this study, the degradation performance of bubbling corona discharge was evaluated on 24 halogenated alicyclic and aliphatic DBPs present in drinking water at concentrations ranging from ng/L to µg/L. The degradation of DBPs followed pseudo-first-order kinetics with rate constants (kobs) in the descending order of halonitromethanes (HNMs), halogenated benzoquinones (HBQs), haloacetonitriles, trihalomethanes (THMs), haloketones, halogenated aldehydes, and haloacetic acids (HAAs). THMs, HNMs, and HBQs were effectively removed within 5 min under a discharge power of 28 W. Degradation rates achieved by plasma treatment surpass those of other conventional treatment technologies. The required energy consumption was in the range of 5-30 kW·h/m3/order. Furthermore, the study investigated the effects of discharge power, initial concentration, and economic analysis on the degradation of four selected DBPs as representatives of mono-, di- and multi-carbon-containing DBPs, namely chloroform (TCM) and bromoform (TBM), tribromoacetic acid (TBAA), and 2,3,5,6-tetrachloro-1,4-benzoquinone (TetraC-BQ). Reactive radicals in the plasma system were investigated using electron paramagnetic resonance, optical emission spectroscopy, fluorimetry, and radical scavengers. Hydrated electrons and hydroxyl radicals played an important role in the removal of DBPs. The intermediates generated during the degradation of TCM, TBM, TBAA, and TetraC-BQ were identified, and the possible degradation pathways for mono- and binary C-DBPs and HBQs were deduced. The breakdown of HBQs did not produce secondary contamination with aliphatic DBPs. The carbon in DBPs was primarily converted to formic acid, acetic acid, and oxalic acid, and the halogens were mainly converted to halogen ions. Additionally, luminescent bacteria toxicity testing confirmed that plasma treatment could reduce the acute toxicity of water samples. These findings demonstrate the potential of plasma treatment as a post-treatment device at the household level.


Assuntos
Desinfetantes , Água Potável , Poluentes Químicos da Água , Purificação da Água , Desinfecção/métodos , Água Potável/química , Desinfetantes/análise , Purificação da Água/métodos , Poluentes Químicos da Água/análise , Halogênios/análise , Carbono/análise , Trialometanos/análise , Halogenação
2.
Water Res ; 240: 120087, 2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-37247438

RESUMO

Up to date, over 700 disinfection byproducts (DBPs) have been detected and identified in drinking water. It has been recognized that cytotoxicity of DBPs varied significantly among groups. Even within the same group, cytotoxicity of different DBP species was also different due to different halogen substitution types and numbers. However, it is still difficult to quantitatively determine the inter-group cytotoxicity relationships of DBPs under the effect of halogen substitution in different cell lines, especially when a large number of DBP groups and multiple cytotoxicity cell lines are involved. In this study, a powerful dimensionless parameter scaling method was adopted to quantitatively determine the relationship of halogen substitution and the cytotoxicity of various DBP groups in three cell lines (i.e., the human breast carcinoma (MVLN), Chinese hamster ovary (CHO), and human hepatoma (Hep G2) cell cytotoxicity) with no need to consider their absolute values and other influences. By introducing the dimensionless parameters Dx-orn-speciescellline and D¯x-orn-speciescellline, as well as their corresponding linear regression equation coefficients ktypeornumbercellline and k¯typeornumbercellline, the strength and trend of halogen substitution influences on the relative cytotoxic potency could be determined. It was found that the effect of halogen substitution type and number on the cytotoxicity of DBPs followed the same patterns in the three cell lines. The CHO cell cytotoxicity was the most sensitive cell line to evaluate the effect of halogen substitution on the aliphatic DBPs, whereas the MVLN cell cytotoxicity was the most sensitive cell line to evaluate the effect of halogen substitution on the cyclic DBPs. Notably, seven quantitative structure activity relationship (QSAR) models were established, which could not only predict the cytotoxicity data of DBPs, but also help to explain and verify the patterns of halogen substitution effect on cytotoxicity of DBPs.


Assuntos
Desinfetantes , Água Potável , Poluentes Químicos da Água , Purificação da Água , Cricetinae , Animais , Humanos , Desinfecção , Halogênios/análise , Água Potável/química , Desinfetantes/análise , Células CHO , Cricetulus , Poluentes Químicos da Água/química , Halogenação
3.
Environ Sci Pollut Res Int ; 26(8): 7305-7314, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29492811

RESUMO

The occurrence of disinfection by-products (DBPs) in drinking water has become an issue of concern during the past decades. The DBPs pose health risks and are suspected to cause various cancer forms, be genotoxic, and have negative developmental effects. The vast chemical diversity of DBPs makes comprehensive monitoring challenging. Only few of the DBPs are regulated and included in analytical protocols. In this study, a method for simultaneous measurement of 20 DBPs from five different structural classes (both regulated and non-regulated) was investigated and further developed for 11 DBPs using solid-phase extraction and gas chromatography coupled with a halogen-specific detector (XSD). The XSD was highly selective towards halogenated DBPs, providing chromatograms with little noise. The method allowed detection down to 0.05 µg L-1 and showed promising results for the simultaneous determination of a range of neutral DBP classes. Compounds from two classes of emerging DBPs, more cytotoxic than the "traditional" regulated DBPs, were successfully determined using this method. However, haloacetic acids (HAAs) should be analyzed separately as some HAA methyl esters may degrade giving false positives of trihalomethanes (THMs). The method was tested on real water samples from two municipal waterworks where the target DBP concentrations were found below the regulatory limits of Sweden.


Assuntos
Cromatografia Gasosa/métodos , Desinfetantes/análise , Água Potável/química , Monitoramento Ambiental/métodos , Halogênios/análise , Poluentes Químicos da Água/análise , Abastecimento de Água , Desinfecção/métodos , Halogenação , Humanos , Suécia , Trialometanos/análise , Purificação da Água/métodos
4.
J Chromatogr A ; 1579: 89-98, 2018 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-30430989

RESUMO

An analytical method employing solid phase extraction (SPE) and gas chromatography-tandem mass spectrometry (GC-MS/MS) has been developed for quantitative determination of twenty-six organohalogen disinfectant by-products (OXBPs) in water samples. Target analytes include four trihalomethanes (THMs), four iodohalomethanes (I-HMs), one haloacetaldehyde (HAL), six haloketones (HKs), four halonitromethanes (HNMs), and seven haloacetonitriles (HANs). The sample preparation procedure includes pretreatment with ascorbic acid to quench residual oxidants, followed by analyte enrichment using solid-phase extraction. Five SPE sorbents were tested. The best results for the majority of target analytes were obtained using a styrene-divinylbenzene copolymer phase and methyl tert-butyl ether (MTBE) as the elution agent. GC-MS analysis was performed using electron ionization (EI) and selected reaction monitoring (SRM) for analyte detection. The performance of the method was assessed according to the French standard NF T90-210. The method showed LOQs ranging from 3 to 3000 ng L-1. The applicability of the method has been demonstrated by analyzing both river water and tap water samples. The OXBPs detected most often in the tap water were dibromochloromethane (in 100% of the samples, 4.3-4.7 µg L-1), bromodichloromethane (100%, 1.3-1.7 µg L-1), tribromomethane (100%, 0.8-4.4 µg L-1), trichloromethane (100%, 0.6-0.7 µg L-1), dibromoacetonitrile (75%, 0.5-0.9 µg L-1), with dichloroacetonitrile and 1,1,1-trichloro-2-propanone detected at concentrations around the LOQ levels. In the treated river water samples, the only OXBPs measured at levels above the limit of quantification were trichloromethane and 1,1,1-trichloro-2-propanone. To the best of our knowledge, this is the first SPE-GC-MS/MS method enabling the analysis of an extensive list of OXBPs.


Assuntos
Desinfetantes/análise , Monitoramento Ambiental/métodos , Cromatografia Gasosa-Espectrometria de Massas , Halogênios/análise , Extração em Fase Sólida , Poluentes Químicos da Água/análise , Água/química , Desinfetantes/isolamento & purificação , Halogênios/isolamento & purificação , Rios/química , Poluentes Químicos da Água/isolamento & purificação
5.
Angew Chem Int Ed Engl ; 57(29): 8989-8993, 2018 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-29846997

RESUMO

Small-molecule-based fluorescent probes have become important tools in biology for sensing and imaging applications. However, the biological applications of many of the fluorescent molecules are hampered by low cellular uptake and high toxicity. In this paper, we show for the first time that the introduction of halogen atoms enhances the cellular uptake of fluorescent molecules and the nature of halogen atoms plays a crucial role in the plasma membrane transport in mammalian cells. The remarkably higher uptake of iodinated compounds compared to that of their chloro or bromo analogues suggests that the strong halogen bonding ability of iodine atoms may play an important role in the membrane transport. This study provides a novel strategy for the transport of fluorescent molecules across the plasma membrane in living cells.


Assuntos
Corantes Fluorescentes/metabolismo , Halogênios/metabolismo , Membrana Celular/metabolismo , Permeabilidade da Membrana Celular , Corantes Fluorescentes/análise , Halogênios/análise , Células Hep G2 , Células Endoteliais da Veia Umbilical Humana , Humanos , Microscopia Confocal , Modelos Moleculares
6.
Anal Bioanal Chem ; 409(20): 4905-4913, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28593369

RESUMO

A simplified, miniaturised matrix solid-phase dispersion (MSPD)-based method allowing the simultaneous extraction and purification of contaminants belonging to selected families of regulated persistent organic pollutants (POPs), i.e. polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and penta- to octa-polybrominated diphenyl ethers (PBDEs), and related contaminants of emerging concern, such as deca-BDE and Dechlorane Plus (DP), has been proposed. Wild bird eggs were used as biotic fat-containing model matrices. Once optimised, the procedure allowed sample preparation to be accomplished within 30 min, in a single step, and with minimal sample and reagent consumption and waste generation. These features contributed to speeding up and greening the analytical process as compared to the large-scale multistep procedures for these types of analyses. The method was combined with gas chromatography-quadrupole mass spectrometry (GC-qMS) for PCB and OCP analysis and with GC-negative ion chemical ionisation-quadrupole mass spectrometry (NCI-qMS) for PBDE and DP determination. The complete analytical method provided satisfactory recoveries of the target compounds (above 83% for all analytes, except for PBDE 209, 63%), although as small an amount of sample as 0.300 g was used. The repeatability of the complete procedure was less than 16% (with the only exception for PCB 153, which looked to be affected by an interference). The limits of detection were in all cases lower than 34 pg g-1 dry weight (as calculated for real samples), demonstrating the feasibility of the proposed procedure for accurate determination of the target compounds in biological samples. The proposed procedure was applied to the analysis of the target POPs in unhatched eggs of wild bird species. Graphical abstract Scheme of the miniaturised methodology proposed for environmental monitoring of POPs and related compounds in wild bird eggs.


Assuntos
Ovos/análise , Poluentes Ambientais/análise , Halogênios/análise , Miniaturização , Animais , Aves , Limite de Detecção , Controle de Qualidade , Reprodutibilidade dos Testes
7.
Anal Bioanal Chem ; 405(1): 389-400, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23070044

RESUMO

Different extraction methods, followed by gas chromatography coupled to triple quadrupole mass spectrometry, were evaluated for simultaneous extraction of seven polychlorinated biphenyls (PCBs) and six polybrominated diphenyl ethers (PBDEs) from common weeds. Pressurized liquid extraction (PLE) with in-cell clean-up, ultrasound-assisted extraction (UAE) with in-column clean-up, and UAE with dispersive solid-phase extraction (dSPE) clean-up were evaluated and compared. In-cell clean-up with 4 g Florisil and 0.5 g graphitized carbon black (GCB) and two extraction cycles of 10 min with n-hexane-ethyl acetate 80:20 (v/v) at 60 °C were used for the PLE procedure. UAE with in-column clean-up was conducted under conditions similar to those reported for the PLE method whereas in UAE with dSPE clean-up purification of the extract was performed after extraction using primary and secondary amine sorbent (PSA) and GCB. Recovery from 82 to 104% was obtained for all the compounds by PLE whereas, in general, lower extraction efficiency was obtained by UAE with in-column clean-up (especially for BDE-17 and BDE-183, for which recovery was 70 and 41%, respectively) and by UAE with dSPE clean-up, for which the main drawback is that BDE-183 cannot be extracted. Finally, PLE was used for analysis of PCBs and PBDEs in different plants (Lolium rigidum, Lactuca serriola, Malva sylvestris, and Verbascum thapsus) collected from residential and/or rural areas of Madrid (Spain). Several of the analyzed compounds were detected at low levels in these plants, but only PCB-153 could be quantified.


Assuntos
Técnicas de Química Analítica/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Halogênios/análise , Extratos Vegetais/metabolismo , Poluentes do Solo/análise , Compostos de Bifenilo/química , Calibragem , Desenho de Equipamento , Peso Molecular , Extratos Vegetais/química , Plantas/metabolismo , Bifenilos Policlorados/análise , Reprodutibilidade dos Testes , Extração em Fase Sólida/métodos , Solventes/química , Fuligem/química , Espanha , Espectrometria de Massas em Tandem/métodos , Temperatura , Fatores de Tempo
8.
Talanta ; 84(3): 673-8, 2011 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-21482266

RESUMO

A silver nanowires modified platinum (Ag NWs/Pt) electrode was developed for simultaneous and selective determination of chloride, bromide and iodide ions by cyclic voltammetry in aqueous solutions. Silver nanowires were synthesized by an l-cysteine-assisted poly (vinyl pyrrolidone) (PVP)-mediated polyol route. X-ray diffraction (XRD) and scanning electron microscopy (SEM), transmission electron microscopy (TEM) and energy dispersive X-ray spectroscopy (EDS) were employed to investigate the prepared nanowires. The intrinsic high surface area and the fast electron transfer rate ascribed from the nanowire structure could further improve halide detection performance. The determination was based on measurement of the well-separated oxidation peak currents of respective silver halides formed on the surface of silver during an anodic potential sweep. The concentration range was linear from 50 µM to 20.2mM for bromide and iodide and 200 µM to 20.2mM for chloride, and the sensitivity was 0.059 µA/mM, 0.042 µA/mM and 0.032 µA/mM for chloride, bromide and iodide, respectively. The correlation coefficient was 0.999 in each case. The Ag NWs/Pt electrode offered a useful platform for the development of a highly sensitive halide sensor.


Assuntos
Eletroquímica/métodos , Halogênios/análise , Nanofios , Prata/química , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Difração de Raios X
9.
Anal Bioanal Chem ; 396(3): 1331-43, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19936718

RESUMO

This article presents the different modes and configurations of liquid-phase microextraction (LPME) through comparison with headspace solid-phase microextraction (HS-SPME) for the simultaneous extraction/methylation of the nine haloacetic acids (HAAs) found in water. This is the first analytical case reported of solvent bar extraction-preconcentration-derivatisation assisted by an ion-pairing transfer for HAAs. In this method, 5 muL of the organic extractant, decane, was confined within a hollow-fibre membrane that was placed in a stirred aqueous sample containing the derivatising reagents (dimethylsulphate with a tetrabutylammonium salt). With heating at 45 degrees C in the HS-SPME method, some organic solvents (extractant, excess of derivatising reagent) are also volatilised and compete with the esters on the fibre (the fibre is damaged and it can be reused only 50-60 times). In addition, the HS-SPME method provides inadequate sensitivity (limits of detections between 0.3 and 5 microg/L) to quantify HAAs at the level usually found in drinking waters. Alternative headspace LPME methods for HAAs require heating (45 degrees C, 25 min) to derivatise and volatilise the esters but, by using solvent bar microextraction (SBME), the extraction/methylation takes place at room temperature without degradation of HAAs to trihalomethanes. Adequate precision (relative standard deviation of approximately 8%), linearity (0.1-500 microg/L) and sensitivity (10 times higher than the HS-SPME alternative) indicate that the SBME method can be a candidate for routine determination of HAAs in tap water. Finally, the SBME method was applied for the analysis of HAAs in tap and swimming pool water and the results were compared with those of a previous validated headspace gas chromatography-mass spectrometry method.


Assuntos
Acetatos/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Halogênios/análise , Microextração em Fase Sólida/métodos , Água/análise , Desinfetantes/análise , Limite de Detecção , Metilação
10.
Biosens Bioelectron ; 24(10): 3008-13, 2009 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-19342215

RESUMO

A screen-printed silver strip with three-electrode configuration of Ag-working, Ag-counter and Ag/Ag(x)O reference electrodes was developed for simultaneous determination of chloride, bromide and iodide in aqueous solutions. It was fabricated simply by screen-printing silver ink onto a polypropylene (PP) base. The in-situ prepared Ag/Ag(x)O reference electrode can avoid the leaching interference in chloride detection while using a conventional Ag/AgCl reference electrode. A single drop of analyte (50 microl) is enough to determine iodide, bromide and chloride by measuring the well-separated oxidation peak currents of respective silver halides. The calibration graph was linear from 10 microM to 20 mM for iodide and bromide and 100 microM to 20 mM for chloride and the detection limit (S/N=3) was 3.05 microM, 2.95 microM and 18.83 microM for iodide, bromide and chloride, respectively. The strip is designed to be disposable and as such manual polishing is not necessary. The proposed sensor is not only simple to manufacture and easy to operate but also fast and precise with little detection volume. It is successfully applied to the determination of halide ions in real samples.


Assuntos
Técnicas Biossensoriais/instrumentação , Halogênios/análise , Ânions/análise , Técnicas Biossensoriais/métodos , Brometos/análise , Cloretos/análise , Técnicas Eletroquímicas , Eletrodos , Iodetos/análise , Prata
11.
J Chromatogr Sci ; 47(1): 67-74, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19161659

RESUMO

Haloacetic acids (HAAs) are a class of byproducts resulting from the reaction of chlorinated disinfectants with natural organic matter. These chemicals have been found in animal studies to possibly influence hepatic, reproductive, and developmental functions, and they may be mutagenic and carcinogenic. Because HAAs are hydrophilic and strongly acidic, it is a challenge to measure them at low levels. In this study, nine traditional HAAs and monoiodoacetic acid, an emerging disinfection byproduct, are analyzed in water directly. HAAs were separated on a BetaMax Acid column or a HILIC UPLC column, and they were detected by negative electrospray ionization-tandem mass spectrometry. Although the on-column limits of detection of HAAs were lower when using an HILIC UPLC column (0.08-2.73 microg/L) than when using a BetaMax Acid column (0.18 to 71.5 microg/L), to use an HILIC UPLC column, it was required to dissolve water samples in 90% acetonitrile before injection and result in sample dilution. BetaMax Acid column was found to be more suitable for the analysis of HAAs in drinking water because there was no need of sample preparation. Major species of HAAs, such as dichloroacetic acid and trichloroacetic acid, and other primary species (e.g., dibromoacetic acid, bromochloroacetic acid and bromodichloroacetic acid) can be detected using the BetaMax Acid column at concentrations higher than 1-3 microg/L.


Assuntos
Acetatos/análise , Cromatografia Líquida de Alta Pressão/métodos , Halogênios/análise , Espectrometria de Massas em Tandem/métodos , Água/análise , Ácido Dicloroacético/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ácido Tricloroacético/análise
12.
Immunol Lett ; 118(2): 125-31, 2008 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-18468695

RESUMO

The expression of NK cells activation receptors was assessed by comparative study of two groups of women workers at a chemical reagents factory, located in Zapopan, Jalisco, Mexico. Twenty of them were exposed to environmental toxics identified and quantified by gas chromatography, and 20 women unexposed to toxic substances. The expression of the surface markers CD56+ and CD3+, and of the activation receptors and co-receptors on NK cells was quantified by flow cytometry. To assess the cellular damage produced by chronic exposure to the toxics, the thiobarbituric acid reacting substances (TBARS) generated and the total plasma antioxidizing capacity (TPAC) were quantified in both groups. The exposed women had been exposed at least to 12 volatile toxic compounds, benzene, benz(a)pyrene, ethylbenzene, dimethylbenz(a)anthracene, xylene, toluene, styrene, chloroform, formaldehyde, iodine, chlorine and fluorine. Significant difference between the two groups was in the proportion of CD3 lymphocytes, 72.7+/-10.3% in the unexposed women versus 66.8+/-7.9% in the exposed group (p<0.05). The density of expression of NKG2D and NKp30 receptors was significantly higher in the unexposed women compared to the exposed group: NKG2D were 31.3+/-6.3 and NKp30 were 9.5+/-5.2 in the unexposed women and 5.14+/-2.9 (p<0.01) and 4.6+/-1.9 (p<0.05), respectively in the exposed women. No statistically significant differences were found in the expression of NKp80, NKp46 and 2B4 receptors. The concentration of TBARS was lower in women from the unexposed group than the corresponding data from women of the exposed group. However, no significant difference was observed in TPAC between the two groups studied. The results of this preliminary study suggest that from the five activation receptors and co-receptors of NK cells evaluated (NKp30, NKp46, NKp80, NKG2D and 2B4), only NKp30 and NKG2D receptor expression was diminished in women exposed to toxics when compared with data from unexposed women. These results suggest that the occupational exposure to mixture of toxics is one of the important factors in the diminution of the NK cell receptor expression.


Assuntos
Poluentes Ambientais/toxicidade , Halogênios/toxicidade , Células Matadoras Naturais/efeitos dos fármacos , Ativação Linfocitária/efeitos dos fármacos , Exposição Ocupacional , Compostos Orgânicos/toxicidade , Receptores de Células Matadoras Naturais/efeitos dos fármacos , Adulto , Antioxidantes/metabolismo , Indústria Química , Feminino , Regulação da Expressão Gênica/efeitos dos fármacos , Halogênios/análise , Humanos , Células Matadoras Naturais/imunologia , México , Pessoa de Meia-Idade , Compostos Orgânicos/análise , Receptores de Células Matadoras Naturais/imunologia , Substâncias Reativas com Ácido Tiobarbitúrico/metabolismo
13.
Environ Sci Technol ; 42(5): 1445-51, 2008 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-18441786

RESUMO

Sodium hypochlorite (NaOCl) and many organic chemicals contained in household cleaning products may react to generate halogenated volatile organic compounds (VOCs). Halogenated VOC emissions from eight different chlorine bleach containing household products (pure and diluted) were investigated by headspace experiments. Chloroform and carbon tetrachloride were the leading compounds along with several halogenated compounds in the headspace of chlorine bleach products. One of the most surprising results was the presence of carbon tetrachloride (a probable human carcinogen and a powerful greenhouse gas that was banned for household use by the U.S. Food and Drug Administration) in very high concentrations (up to 101 mg m(-3)). By mixing surfactants or soap with NaOCl, it was shown that the formation of carbon tetrachloride and several other halogenated VOCs is possible. In addition to quantitatively determined halogenated VOCs (n = 15), several nitrogen-containing (n = 4), chlorinated (n = 10), oxygenated compounds (n = 22), and hydrocarbons (n = 14) were identified in the headspace of bleach products. Among these, 1,1-dichlorobutane and 2-chloro-2-nitropropane were the most abundant chlorinated VOCs, whereas trichloronitromethane and hexachloroethane were the most frequently detected ones. Indoor air halogenated VOC concentrations resulting from the use of four selected household products were also measured before, during, and 30 min after bathroom, kitchen, and floor cleaning applications. Chloroform (2.9-24.6 microg m(-3)) and carbon tetrachloride (0.25-459 microg m(-3)) concentrations significantly increased during the use of bleach containing products. During/ before concentration ratios ranged between 8 and 52 (25 +/- 14, average +/- SD) for chloroform and 1-1170 (146 +/- 367, average +/- SD) for carbon tetrachloride, respectively. These results indicated that the bleach use can be important in terms of inhalation exposure to carbon tetrachloride, chloroform and several other halogenated VOCs.


Assuntos
Halogênios/análise , Produtos Domésticos , Compostos Orgânicos/análise , Hipoclorito de Sódio/análise , Poluição do Ar em Ambientes Fechados , Controle de Qualidade , Volatilização
14.
J Chromatogr A ; 1178(1-2): 206-14, 2008 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-18067901

RESUMO

This work studies the stability of three UV filters: 2-ethylhexyl salicylate (ES), 2-ethylhexyl 4-(dimethylamino) benzoate (EHPABA) and 2-hydroxy-4-methoxybenzophenone (BP-3), in water samples containing low concentrations of free chlorine. Moreover, 2,4-dihydroxybenzophenone (2,4-DHBP), a metabolite of BP-3, was also included in some of the performed assays. Experiments were carried out considering free chlorine and analytes concentrations at the microg mL(-1) and ng mL(-1) level, respectively. Gas chromatography with mass spectrometry was used to follow the time course of target compounds and to identify their halogenated by-products. Concentration of water samples with solid-phase extraction cartridges and derivatization (silylation) of some species were also employed to improve their detectability. Under the experimental conditions explored in this work, ES showed an acceptable stability whereas the rest of species reacted with free chlorine at significant rates following pseudo-first-order kinetics. Their half-lives ranged from 0.4 to 25 min depending on the UV filter, chlorine concentration, water pH and presence of bromide traces. For EHPABA a relatively simple degradation pathway was established. It consisted of aromatic substitution of one atom of hydrogen per chlorine or bromide. The same reaction pattern was observed for BP-3 leading, in this case, to mono- and di-halogenated by-products. In addition, several halogenated forms of 3-methoxyphenol were identified as BP-3 cleavage by-products.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Halogênios/análise , Cloro/análise , Halogênios/isolamento & purificação , Água/análise
15.
Klin Med (Mosk) ; 85(11): 42-6, 2007.
Artigo em Russo | MEDLINE | ID: mdl-18219955

RESUMO

The authors studied the effects of anesthesia with equipotential concentrations of halothane, enflurane, and isoflurane plus 33% O2 on central hemodynamics, coronary flow, and myocardial metabolism in 60 patients undergoing myocardial revascularization surgery. The study found that halothane and isoflurane with 33% O2 caused dose-dependent and well-controlled arterial hypotension and decreased left ventricular (LV) stroke work index, myocardial consumption of O2 MCO2), total peripheral vascular resistance, and coronary vascular resistance (CVR), which increased coronary volume flow. Monoanesthesia with enflurane lowered myocardial contractility and did not change LV work; MCO2 decreased, while coronary sinus flow increased due to a decrease in CVR. Thus, the comparison of hemodynamic and myocardial effects of the three potent inhaled anesthetics--halothane, enflurane, and isoflurane - demonstrated their positive effects on myocardial oxygen balance in a form of dosed and controlled decrease in its work in cardiological patients with preserved LV contractility. The imported anesthetics enflurane and isoflurane do not have any significant advantage over the Russian-made halothane in this category of patients. At the same time, halothane vs. enflurane has a more noticeable "unloading" effect on afterload and does not cause convulsive episodes and periods of cerebral activity depression; in contrast to isoflurane, halothane dose not cause metabolic disturbances in a compromised myocardium; halothane is used in lower inhaled concentrations to achieve the same degree of myocardial work decrease without a substantial decrease in cardiac efficiency. These facts suggest that halothane has a practical advantage over the other anesthetics.


Assuntos
Anestésicos/química , Halogênios/análise , Coração/efeitos dos fármacos , Isquemia Miocárdica/metabolismo , Miocárdio/metabolismo , Adulto , Hemodinâmica/efeitos dos fármacos , Humanos , Pessoa de Meia-Idade , Oxigênio/metabolismo , Cuidados Pré-Operatórios
16.
Environ Sci Technol ; 38(24): 6605-9, 2004 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-15669318

RESUMO

The depletion of stratospheric ozone due to the effects of ozone-depleting substances, such as volatile organohalogens, emitted into the atmosphere from industrial and natural sources has increased the amount of ultraviolet radiation reaching the earth's surface. Especially in the subpolar and polar regions, where stratospheric ozone destruction is the highest, individual organisms and whole ecosystems can be affected. In a laboratory study, several species of marine macroalgae occurring in the polar and northern temperate regions were exposed to elevated levels of ultraviolet radiation. Most of the macroalgae released significantly more chloroform, bromoform, dibromomethane, and methyl iodide-all volatile organohalogens. Calculating on the basis of the release of total chlorine, bromine, and iodine revealed that, except for two macroalgae emitting chlorine and one alga emitting iodine, exposure to ultraviolet radiation caused macroalgae to emit significantly more total chlorine, bromine, and iodine. Increasing levels of ultraviolet radiation due to possible further destruction of the stratospheric ozone layer as a result of ongoing global atmospheric warming may thus increase the future importance of marine macroalgae as a source for the global occurrence of reactive halogen-containing compounds.


Assuntos
Eucariotos/química , Eucariotos/fisiologia , Oxidantes Fotoquímicos/química , Ozônio/química , Raios Ultravioleta , Halogênios/análise , Água do Mar , Temperatura , Volatilização
17.
J Chromatogr A ; 1019(1-2): 143-56, 2003 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-14650611

RESUMO

The separation of 38 toxic and predominant polychlorinated biphenyl (PCB) congeners, 11 persistent halogenated pesticides, 1 brominated biphenyl (BB), and 8 polybrominated diphenyl ethers (PBDEs) has been optimized using comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC x GC-TOFMS). A thermal desorption-programmable temperature vaporization (TD-PTV) step was used for the injection. Different column sets were investigated, and a 100% dimethylpolysiloxane (15 m x 0.25 mm i.d. x 0.25 microm film thickness) narrowbore capillary column coupled to a high temperature (8% phenyl)-polycarborane-siloxane (2 m x 0.10 mm i.d. x 0.10 microm film thickness) microbore column set was selected. Of the 58 compounds investigated, only one pair of PCBs was not resolved. All other analytes were either baseline separated into the chromatographic plane or were virtually separated using the deconvolution capability of the TOFMS.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Halogênios/análise , Sensibilidade e Especificidade
18.
Anal Chem ; 75(16): 4065-80, 2003 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-14632119

RESUMO

Haloacetic acids (HAAs) are environmentally and medically important chemicals. No analytical method is currently available to analyze EPA-regulated HAAs in biological samples at environmentally relevant low concentrations. Clinical studies of this class of chemicals are also limited by the lack of analytical techniques of high sensitivity and precision. We now report a new analytical method using gas chromatography/ion trap mass spectrometry for quantifying nine HAAs present inplasma, urine, and water at picogram per milliliter levels. The derivatization reactions of HAAs with pentafluorobenzyl bromide were optimized and detection with an electron capture negative ion chemical ionization mode was employed to enhance the sensitivity. Selected ion monitoring and selected reaction monitoring methods were utilized for quantitation. The detection limits of HAAs in plasma, urine, and water were 25-1000 pg/mL. Accuracies varied from 86.6 to 118.1% (intraday) and 81.7 to 119.6% (interday). Precisions (CV) varied from 0.9 to 19.9% (intraday) and 0.8 to 19.8% (interday), and linearities (r2) varied from 0.9732 to 0.9998 (intraday) and 0.9422 to 0.9987 (interday), respectively. Methyl tertbutyl ether and diethyl ether provided the highest extraction recoveries for the HAAs (74.9-107.2%). The method was applied successfully to a kinetic investigation of low levels of HAAs in humans consuming chlorinated drinking water.


Assuntos
Acetatos/análise , Fluorbenzenos/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Halogênios/análise , Acetatos/química , Cloro/análise , Halogênios/química , Humanos , Reprodutibilidade dos Testes , Poluentes Químicos da Água/análise
19.
Environ Sci Technol ; 36(8): 1734-41, 2002 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-11993871

RESUMO

Uptake of ferrous iron from aqueous solution by iron oxides results in the formation of a variety of reactive surface species capable of reducing polyhalogenated methanes (PHMs). Pseudo-first-order reaction rate constants, k(obs), of PHMs increased in the order CHBrCl2 < CHBr2Cl < CHBr3 < CCl4 < CFBr3 < CBrCl3 < CBr2Cl2. The k(obs) values increased with the exposure time, teq, of Fe(II) to suspended iron oxides which was attributed to the rearrangement of initially sorbed Fe(II) species to more reactive surface species with time. At pH 7.2, the k(obs) values of PHMs also increased with the concentration of surface-bound ferrous iron, Fe(II)sorb, particularly when Fe(II)tot was increased to concentrations where surface precipitation becomes likely. At fixed total Fe(II) concentrations, k(obs) values increased exponentially with pH. The highest reactivities were associated with pH conditions where surface precipitation of Fe(II) is expected. Fe(II)sorb and pH, however, had opposite effects on the product formation of PHMs. At pH 7.2, the formation of formate from CX4 (X = CI, Br) increased with Fe(II)sorb, whereas increasing pH favored the formation of CHX3. The ratio of halogenated products and formate formed is indicative of the relative importance of initial one- or two-electron-transfer processes, respectively, and was found to depend on the type of iron oxide mineral also. Our data form a basis to assess the importance of chemical reactions in natural attenuation processes of PHMs in environmental systems under iron-reducing conditions.


Assuntos
Compostos Ferrosos/análise , Metano/química , Poluentes da Água/análise , Compostos Férricos/química , Halogênios/análise , Halogênios/química , Cinética , Metano/análogos & derivados , Metano/análise
20.
Spectrochim Acta A Mol Biomol Spectrosc ; 58(5): 1083-6, 2002 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-11942394

RESUMO

An attempt has been made to generate the metastable phosphorus (III) oxythiocyanide molecule, OP-SCN for the first time by an on-line process using the vapor flow of phosphorus (III) oxychloride, OPCl passed over heated AgSCN at 520 degrees C. The products have been characterized by their IR spectra; values for v1 of 2055 cm(-1) (C[triple bond]N stretch), v2 of 1365 cm(-1) (O=P stretch), v3 of 720 cm(-1) (C-S stretch) and v7 of 680 cm(-1) (P-S stretch) have been obtained.


Assuntos
Cianetos/análise , Cianetos/química , Fósforo/química , Espectrofotometria Infravermelho/métodos , Halogênios/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA