Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.954
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Cochrane Database Syst Rev ; 5: CD013421, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38695613

RESUMO

BACKGROUND: During vascular interventions, connections that link arteries, veins, or synthetic grafts, which are known as an 'anastomosis', may be necessary. Vascular anastomoses can bleed from the needle holes that result from the creation of the anastomoses. Various surgical options are available for achieving hemostasis, or the stopping of bleeding, including the application of sealants directly onto the bleeding vessels or tissues. Sealants are designed for use in vascular surgery as adjuncts when conventional interventions are ineffective and are applied directly by the surgeon to seal bleeding anastomoses. Despite the availability of several different types of sealants, the evidence for the clinical efficacy of these hemostatic adjuncts has not been definitively established in vascular surgery patients. OBJECTIVES: To evaluate the benefits and harms of sealants as adjuncts for achieving anastomotic site hemostasis in patients undergoing vascular surgery. SEARCH METHODS: The Cochrane Vascular Information Specialist conducted systematic searches of the following databases: the Cochrane Vascular Specialised Register via the Cochrane Register of Studies; the Cochrane Central Register of Controlled Trials (CENTRAL); MEDLINE via Ovid; Embase via Ovid ; and CINAHL via EBSCO. We also searched ClinicalTrials.gov and the WHO International Clinical Trials Registry Platform for clinical trials. Reference lists of included trials and relevant reviews were also searched. The latest search date was 6 March 2023. SELECTION CRITERIA: We included randomized controlled trials that compared fibrin or synthetic sealant use with alternative interventions (e.g. manual compression, reversal of anticoagulation) for achieving anastomotic-site hemostasis in vascular surgery procedures. We included participants who underwent the creation of an anastomosis during vascular surgery. We excluded non-vascular surgery patients. DATA COLLECTION AND ANALYSIS: We have used standard Cochrane methods. Our primary outcomes were time to hemostasis, failure of hemostatic intervention, and intraoperative blood loss. Our secondary outcomes were operating time, death from bleeding complications up to 30 days, postoperative bleeding up to 30 days, unplanned return to the operating room for bleeding complications management up to 30 days, quality of life, and adverse events. We used GRADE to assess the certainty of evidence for each outcome. MAIN RESULTS: We found 24 randomized controlled trials that included a total of 2376 participants who met the inclusion criteria. All trials compared sealant use with standard care controls, including oxidized cellulose, gelatin sponge, and manual compression. All trials were at high risk of performance bias, detection bias, and other sources of bias. We downgraded the certainty of evidence for risk of bias concerns, inconsistency, imprecision and possible publication bias. Combining data on time to hemostasis showed that sealant use may reduce the mean time to hemostasis compared to control (mean difference (MD) -230.09 seconds, 95% confidence interval (CI) -329.24 to -130.94; P < 0.00001; 7 studies, 498 participants; low-certainty evidence). Combining data on failure of hemostatic intervention showed that sealant use may reduce the rate of failure compared to control, but the evidence is very uncertain (risk ratio (RR) 0.46, 95% CI 0.35 to 0.61; P < 0.00001; 17 studies, 2120 participants; very low-certainty evidence). We did not detect any clear differences between the sealant and control groups for intraoperative blood loss (MD -32.69 mL, 95% CI -96.21 to 30.83; P = 0.31; 3 studies, 266 participants; low-certainty evidence); operating time (MD -18.72 minutes, 95% CI -40.18 to 2.73; P = 0.09; 4 studies, 436 participants; low-certainty evidence); postoperative bleeding (RR 0.78, 95% CI 0.59 to 1.04; P = 0.09; 9 studies, 1216 participants; low-certainty evidence), or unplanned return to the operating room (RR 0.27, 95% CI 0.04 to 1.69; P = 0.16; 8 studies, 721 participants; low-certainty evidence). No studies reported death from bleeding or quality of life outcomes. AUTHORS' CONCLUSIONS: Based on meta-analysis of 24 trials with 2376 participants, our review demonstrated that sealant use for achieving anastomotic hemostasis in vascular surgery patients may result in reduced time to hemostasis, and may reduce rates of hemostatic intervention failure, although the evidence is very uncertain, when compared to standard controls. Our analysis showed there may be no differences in intraoperative blood loss, operating time, postoperative bleeding up to 30 days, and unplanned return to the operating room for bleeding complications up to 30 days. Deaths and quality of life could not be analyzed. Limitations include the risk of bias in all studies. Our review has demonstrated that using sealants may reduce the time required to achieve hemostasis and the rate of hemostatic failure. However, a significant risk of bias was identified in the included studies, and future trials are needed to provide unbiased data and address other considerations such as cost-effectiveness and adverse events with sealant use.


Assuntos
Anastomose Cirúrgica , Hemostasia Cirúrgica , Ensaios Clínicos Controlados Aleatórios como Assunto , Procedimentos Cirúrgicos Vasculares , Humanos , Hemostasia Cirúrgica/métodos , Hemostáticos/uso terapêutico , Adesivo Tecidual de Fibrina/uso terapêutico , Perda Sanguínea Cirúrgica/prevenção & controle , Adesivos Teciduais/uso terapêutico
2.
Auris Nasus Larynx ; 51(3): 512-516, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38522355

RESUMO

Hemostatic procedures for controlling nasal bleeding in refractory diseases such as hereditary hemorrhagic telangiectasia (HHT) can be challenging. In this report, we present a novel technique for underwater endoscopic endonasal hemostatic surgery, which was performed on a 69-year-old man with HHT. The patient had been experiencing frequent episodes of nasal bleeding and had many telangiectasias in the nasal cavity, which were the cause of the bleeding. These telangiectasias were effectively treated using a coblation device in combination with an endoscope lens-cleaning system that supplied saline to create stable underwater conditions. There are several advantages to this technique, including provision of a stable and clear endoscopic field of view, allowing for better visualization of the surgical site. This makes it easier to identify bleeding points and ensure accurate hemostasis. Additionally, the hydrostatic pressure created by the underwater environment helps to reduce bleeding during the procedure. However, it is important to take careful precautions to prevent water from entering the lower airway. With this precautionary measure, this technique is particularly useful in managing bleeding in patients with HHT.


Assuntos
Epistaxe , Telangiectasia Hemorrágica Hereditária , Humanos , Telangiectasia Hemorrágica Hereditária/complicações , Telangiectasia Hemorrágica Hereditária/cirurgia , Idoso , Masculino , Epistaxe/cirurgia , Cavidade Nasal/cirurgia , Hemostase Endoscópica/métodos , Hemostase Endoscópica/instrumentação , Endoscopia/métodos , Cirurgia Endoscópica por Orifício Natural/métodos , Hemostasia Cirúrgica/métodos , Hemostasia Cirúrgica/instrumentação
3.
Innovations (Phila) ; 19(2): 143-149, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38504149

RESUMO

OBJECTIVE: This study evaluated the efficacy of the Minimally Invasive Targeted Resection (MiTR) device, a novel electrosurgical instrument that allows for targeted excision of a lung abnormality while using bipolar radiofrequency (RF) energy to seal blood vessels and airways. METHODS: The MiTR system was evaluated in 7 acute and 2 chronic porcine (7-day) models to evaluate the efficacy of tissue excision with bipolar RF sealing of blood vessels and airways and application of an autologous blood patch into the excised tissue cavity. Air leak was recorded for all evaluations. The study was approved by the institutional ethical board. RESULTS: Nineteen lung tissue samples, measuring 2.5 cm long × 1.2 cm diameter, were excised. In 8 of 9 animals (89%), hemostasis and pneumostasis were observed visually at the completion of the procedure. In 2 of 2 chronic animals (100%), hemostasis and pneumostasis persisted for the 7-day observation period. Histologic examination of the excised samples showed preservation of the core parenchymal architecture without evident tissue damage of the samples that would impair pathologic analysis. CONCLUSIONS: Percutaneous resection of targeted lung tissue with the MiTR system demonstrated hemostasis and pneumostasis while obtaining a histologically intact sample. After regulatory approval, the use of this device could offer more tissue for analysis than a transthoracic needle biopsy or bronchoscopy and a far less invasive alternative to video-assisted thoracic surgery or thoracotomy. This may also expand patient and physician options for the early diagnosis and treatment of lung cancer.


Assuntos
Pulmão , Animais , Suínos , Pulmão/cirurgia , Pulmão/patologia , Pneumonectomia/instrumentação , Pneumonectomia/métodos , Eletrocirurgia/instrumentação , Eletrocirurgia/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Hemostasia Cirúrgica/instrumentação , Hemostasia Cirúrgica/métodos , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação
4.
Spine J ; 24(6): 933-946, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38219838

RESUMO

Spinal surgery can be associated with significant intraoperative blood loss which may lead to various complications. As the number of patients undergoing spinal surgery increases over time, accurate and effective hemostasis becomes critically important. Despite various surgical hemostatic techniques, conventional interventions such as compression, suture, ligation, and heat-generating cautery, are not suitable for osseous and epidural venous plexus bleeding during spinal procedures. Therefore, a variety of hemostatic agents have been developed to promote hemostasis. As they differ in terms of mechanism, form, application and potential adverse reactions, it is important to understand the natural features of existing agents. Here we comprehensively review currently available topical hemostatic agents from different sources and summarize their mechanisms of action, applications, and current or potential utilization in spinal surgery. We found hemostatic agents from different sources exert hemostatic actions through different mechanisms. In addition, topical hemostatic agents play various roles in spinal surgery including as hemostatic agent, dura mater repair, drug-carrier, skin closure, and fibrosis prevention. Compressive neurological complications are the most common complications of these hemostatic agents. Therefore, optimal use in spinal environments should match their features, indications, and efficacy with clinical conditions.


Assuntos
Perda Sanguínea Cirúrgica , Hemostáticos , Coluna Vertebral , Humanos , Hemostáticos/administração & dosagem , Hemostáticos/efeitos adversos , Coluna Vertebral/cirurgia , Perda Sanguínea Cirúrgica/prevenção & controle , Administração Tópica , Hemostasia Cirúrgica/métodos
6.
BMC Pregnancy Childbirth ; 24(1): 9, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166803

RESUMO

BACKGROUND: Intractable postpartum hemorrhage (PPH) during cesarean section has been a significant concern for obstetricians. We aimed to explore the effectiveness and safety of a new type of uterine compression suture, the step-wise surgical technique of knapsack-like sutures for treating intractable PPH caused by uterine atony and placenta factors in cesarean section. METHODS: The step-wise surgical technique of knapsack-like sutures was established on the basis of the artful combination of vertical strap-like sutures and an annular suture-ligation technique. This novel surgical technique was applied to 34 patients diagnosed with PPH during cesarean section due to severe uterine atony and placental factors in our department. The hemostatic effects, clinical outcomes and follow-up visit results were all reviewed and analyzed. RESULTS: This new uterine compression suture successfully stopped bleeding in 33 patients, and the effective rate was 97.06%. Only 1 patient failed and was changed to use bilateral uterine arterial embolization and internal iliac artery embolization. The follow-up visits indicated that 33 patients restored menstruation except for 1 who was diagnosed with amenorrhea. The gynecological ultrasound tests of all the patients suggested good uterine involutions, and they had no obvious complaints such as hypogastralgia. CONCLUSIONS: This step-wise surgical technique of knapsack-like uterine compression sutures can compress the uterus completely. It is a technique that can conserve the uterus and fertility function without special equipment in caesarean section for PPH, with the characteristics of being safe, simple and stable (3 S) with rapid surgery, reliable hemostasis and resident doctor to operation (3R).


Assuntos
Hemorragia Pós-Parto , Inércia Uterina , Feminino , Humanos , Gravidez , Hemorragia Pós-Parto/cirurgia , Hemorragia Pós-Parto/etiologia , Cesárea/efeitos adversos , Inércia Uterina/cirurgia , Hemostasia Cirúrgica/métodos , Placenta/cirurgia , Útero/cirurgia , Útero/irrigação sanguínea , Suturas/efeitos adversos , Técnicas de Sutura/efeitos adversos
7.
J Clin Neurosci ; 120: 30-35, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38176112

RESUMO

Intraoperative bleeding poses a substantial challenge, particularly in neuro-spine surgeries leading to complications such as hematomas, infections, and hemodynamic instability. Despite their proven efficacy, use of topical hemostatic agents (THAs) lacks comprehensive published literature and guidelines particularly in the Indian setting. The present study provides the first-ever Indian expert panel recommendations for effective adjunct THA use in different intraoperative bleeding sites and situations in neuro-spine surgeries. A comprehensive approach, encompassing a literature review, followed by experience sharing in a meeting using a survey helped integrate expert opinions in the form of practical algorithms to guide THA selection. Our survey results revealed a strong inclination towards specific THAs, flowable gelatin + thrombin being choice of THA for difficult to access and problematic bleeding situations during tumor removal/resection, transsphenoidal hypophysectomy and skull-based procedures. Both oxidized regenerated cellulose (ORC)/Fibrillar and flowable gelatin + thrombin were recommended for continuous oozing. ORC/Fibrillar was preferred for arteriovenous and cavernous malformations. This expert-panel guidance on THA use aims to optimize hemostat use practices and improve surgical outcomes in neuro-spine surgery.


Assuntos
Hemostáticos , Humanos , Hemostáticos/uso terapêutico , Trombina/uso terapêutico , Gelatina , Hemostasia Cirúrgica , Perda Sanguínea Cirúrgica/prevenção & controle
8.
Gen Thorac Cardiovasc Surg ; 72(5): 331-337, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37837565

RESUMO

BACKGROUND: Advanced vessel sealing electrosurgical systems have been widely adopted for grasping, cutting, and sealing vessels. Data remain sparse with regard to its use in thoracic procedures. Thus, a prospective case series, utilizing the ENSEAL X1 Curved Jaw Tissue Sealer (X1CJ) and its companion energy source, the Generator 11 (GEN11), in thoracic procedures was performed in a Japanese cohort. METHODS: Subjects were recruited at two Japanese surgical sites. The primary endpoint of this post-market study was the achievement of hemostasis (≤ Grade 3) for each thoracic vessel transection. Performance endpoints included scores for tasks completed with X1CJ (adhesiolysis, lymphatics or tissue bundles divided, tissue grasping, tissue cutting, or tissue dissection); hemostasis grading vessel transected; additional products required to achieve hemostasis for Grade 4 vessel transections. Safety was evaluated by evaluating device-related adverse events. All endpoint data were summarized. RESULTS: Forty subjects (50.0% female) of Asian ethnicity with a mean age of 67.6 ± 11.3 years underwent a lung resection. Estimated mean blood loss was 39.5 mL. Hemostasis was achieved in 97.5% of vessel transections. Thirty-seven vessel sealings resulted in a hemostatic Grade 1 (92.5%). All surgeons reported satisfaction/neutral in terms of tissue grasping (100.0%) while most reported satisfaction/neutral with tissue cutting (95.7%). One device-related serious adverse event was reported (2.5%), a chylothorax requiring an extension of hospitalization. There was no post-operative bleeding or deaths reported during the study period. CONCLUSION: The X1CJ demonstrated safe and effective performance without any reports of significant intra-operative or post-operative hemorrhage in thoracic vessel sealing.


Assuntos
Hemostasia Cirúrgica , Hemorragia Pós-Operatória , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Hemostasia Cirúrgica/métodos , Japão , Hemorragia Pós-Operatória/etiologia
9.
Am J Cardiol ; 209: 181-183, 2023 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-37863115

RESUMO

Suture-mediated closure device and Figure-of-Eight suture are commonly used to achieve hemostasis after use of large bore venous access. Although both methods of closure are commonly used in clinical practice, a head-to-head comparison in a controlled setting has not been performed. Patients presenting to a single center for elective left atrial appendage occlusion or transcatheter edge-to-edge mitral valve repair were randomized to large bore venous closure using the Perclose ProGlide suture-based closure or a Figure-of-Eight suture closure. The patients were followed for 1 month after the procedure. Primary outcome, a composite of access site large ecchymosis, hematoma, infection, pain, need for unscheduled venous ultrasound and need for transfusion, was compared between the 2 arms. A total of 40 patients were randomized in a 1:1 fashion to the 2 venous closure strategies. Baseline characteristics were similar between the 2 groups. Perclose ProGlide arm required use of more devices for hemostasis (1.5 ± 0.5 vs 1 ± 0 respectively, p <0.0001), and there was a significant difference in the cost of closure device ($367.00 ± 122.00 vs $1.00 ± 0 respectively, p <0.001). At 1 month post-procedure, the primary outcome occurred in 4 patients (20%) in the Perclose arm and 7 (35%) patients in the Figure-of-Eight arm, a difference that was not statistically significant (p = 0.48). Time to hemostasis between Figure-of-Eight and Perclose arms did not reach statistical significance (2.5 ± 2.1 vs 3.7 ± 2.3, p = 0.09). In conclusion, both Perclose ProGlide suture-based device and Figure-of-Eight closure are equally feasible and safe for patients who underwent large bore venous access. Figure-of-Eight-based closure is more cost effective.


Assuntos
Hemostasia Cirúrgica , Dispositivos de Oclusão Vascular , Humanos , Artéria Femoral/cirurgia , Hemostasia , Hemostasia Cirúrgica/métodos , Técnicas Hemostáticas , Técnicas de Sutura , Suturas , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares
10.
World Neurosurg ; 178: 241-259.e3, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37586555

RESUMO

BACKGROUND: Hemostasis is crucial in preventing hemorrhage during cranial neurosurgical procedures and maintaining visualization of the surgical field. There is significant variation in the availability of hemostatic methods across different settings and hemostatic techniques are being continuously developed over the decades of practicing neurosurgery. The aim of this article is to provide an outline of the potential methods to achieve hemostasis based on the sequential operative anatomy of a cranial operation. METHODS: A systematic review was conducted following the PRISMA guidelines. The PubMed database was searched from inception of the database to July 18, 2023. A total of 64 studies were identified fulfilling predefined inclusion criteria, and the risk of bias was assessed using the Joanna Briggs Institute checklists. RESULTS: Seventy-one hemostatic agents, techniques, tools, and devices were identified, which were then categorized according to the operative phase for which they are indicated. Nine operative anatomic targets were addressed in the sequence in which they are involved during a cranial procedure. For each anatomic target, the following number of hemostatic techniques/agents were identified: 11 for scalp, 3 for periosteum, 10 for skull bone, 11 for dura mater, 9 for venous sinuses, 5 for arteries, 6 for veins, 12 for brain parenchyma, and 4 for cerebral ventricles. CONCLUSIONS: Depending on the phase of the surgery and the anatomic structure involved, the selection of the appropriate hemostatic method is determined by the source of bleeding. Surgeon awareness of all the potential techniques that can be applied to achieve hemostasis is paramount, especially when faced with operative nuances and difficult-to-control bleeding during cranial neurosurgical procedures.


Assuntos
Hemostáticos , Neurocirurgia , Humanos , Hemostáticos/uso terapêutico , Procedimentos Neurocirúrgicos/métodos , Hemostasia , Crânio/cirurgia , Hemostasia Cirúrgica/métodos
12.
J Clin Neurosci ; 114: 70-76, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37321020

RESUMO

OBJECTIVE: Rapid and efficacious haemostasis is paramount in neurosurgery. Assessing the efficacy and short- and long-term safety of haemostatic agents utilised within cerebral tissue is essential. This pilot study investigates the haemostatic efficacy and long-term safety of a novel beta-chitin patch against traditionally used agents, bipolar and Floseal, within cerebral tissue. METHODS: Eighteen Merino sheep underwent standardised distal cortical vessel injury via temporal craniotomy. Sheep were randomised to receive 2 mls Floseal, 2 cm novel beta-chitin patch, or bipolar cautery to manage bleeding. All sheep underwent cerebral magnetic resonance imaging (MRI) at three months, before euthanasia and brain harvesting for histological assessment. RESULTS: Beta-chitin demonstrated a trend towards a faster mean time to haemostasis (TTH) compared to Floseal (223.3 ± 199 s v. 259.8 ± 186.4 s), albeit non-significant (p = 0.234). Radiologically, cerebrocortical necrosis (p = 0.842) and oedema (p = 0.368) were noted slightly more frequently in the beta-chitin group. Histologically, severe fibrotic (p = 0.017) and granulomatous changes at the craniotomy sites were only present in the beta-chitin group (p = 0.002). Neuronal degeneration was seen in all with Floseal, but beta-chitin showed a trend towards more severe reaction when present. Bipolar use predominantly showed an inflammatory cortical reaction with substantial microvascular proliferation, and Floseal showed worse severity and depth of subpial oedema, however no statistical significance was reached. CONCLUSION: All haemostats controlled bleeding, with beta-chitin demonstrating a non-inferior TTH compared to Floseal. However, it resulted in intense granulomatous and fibrotic changes, including degenerative neuronal reactions. More extensive studies are needed to assess these trends, to make further clinical inferences.


Assuntos
Hemostáticos , Ovinos , Animais , Hemostáticos/farmacologia , Projetos Piloto , Esponja de Gelatina Absorvível , Hemostasia , Hemostasia Cirúrgica/métodos , Quitina/farmacologia , Quitina/uso terapêutico
13.
Eur Rev Med Pharmacol Sci ; 27(3 Suppl): 135-140, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37129324

RESUMO

Sufficient hemostasis during oral surgical procedures is crucial for successful outcomes and to reduce healthcare resource utilization. The purpose of this narrative review is to give a rational insight into the management of bleeding in oral and dental practice through modern drugs. A narrative literature review has been performed on the present topic identifying all articles on Pubmed/Medline and Google Scholars. Acceptable hemostasis during oral surgery is also required to improve visibility and provide a dry operational area. Many oral surgeons, in their daily practice, encounter problems in controlling postoperative bleeding and use a topical hemostatic agent to promote platelet activation or aggregation to form a stable clot.


Assuntos
Hemostáticos , Procedimentos Cirúrgicos Bucais , Humanos , Hemorragia Pós-Operatória , Hemostasia Cirúrgica/métodos , Hemostasia , Hemostáticos/farmacologia , Perda Sanguínea Cirúrgica , Administração Tópica
14.
Gen Thorac Cardiovasc Surg ; 71(9): 505-514, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36917374

RESUMO

OBJECTIVES: Matsudaito is a unique surgical sealant with a powerful hemostatic effect that works independent of a patient's blood coagulation function. Because of its mechanism, this sealant is expected to be particularly useful in patients with a poor blood coagulation function, such as in cases of acute aortic syndrome requiring emergency surgery. We, therefore, evaluated the hemostatic static effect of the sealant in both emergency and elective surgery of the thoracic aorta. METHODS: We used data obtained from post-marketing surveillance of the sealant. Patients who underwent replacement of the thoracic aorta were enrolled. The hemostatic effect was evaluated as effective if a further hemostatic procedure was not performed after applying the sealant. RESULTS: From 46 hospitals in Japan, a total of 542 patients (327 elective and 215 emergency cases) were enrolled. Hospital mortality was 4.0% and 11.6% in elective and emergency cases, respectively (p < 0.05). Among the 1039 anastomoses (609 elective and 430 emergency cases), effective hemostasis was confirmed in 436 (71.6%) elective and 259 (60.2%) emergency cases. The data from the clinical trial of the sealant showed a hemostatic rate of 44.4% in elective control cases without the sealant. CONCLUSION: Given that the hemostatic rate in emergency surgery with the sealant seemed to be better than that in elective surgery without the sealant (determined from the clinical trial), we concluded that the sealant was effective in both emergency and elective thoracic surgery of the aorta.


Assuntos
Hemostáticos , Humanos , Aorta Torácica/cirurgia , Coagulação Sanguínea , Hemostasia , Hemostasia Cirúrgica/métodos , Hemostáticos/uso terapêutico , Hemostáticos/farmacologia , Resultado do Tratamento , Ensaios Clínicos como Assunto
15.
Artigo em Espanhol | LILACS | ID: biblio-1431956

RESUMO

El manejo del sangrado en CEF es fundamental, ya que aumenta la tasa de complicaciones. El principal objetivo del manejo perioperatorio es lograr una buena hemostasia, es por esto que se realizó una revisión de las principales recomendaciones de la literatura internacional, que incluye medidas preoperatorias, intraoperatorias y postoperatorias.


Bleeding is an important factor in FESS since it increases the rate of complications. The main objective of perioperative management is to achieve good hemostasis. This is a review of the main recommendations of the international literature, that includes preoperative, intraoperative and postoperative measures.


Assuntos
Humanos , Endoscopia/métodos , Hemostasia Cirúrgica/métodos , Cuidados Pós-Operatórios , Cuidados Pré-Operatórios , Prednisona/uso terapêutico , Solução Salina , Cuidados Intraoperatórios , Anti-Inflamatórios/uso terapêutico
18.
Updates Surg ; 74(5): 1521-1531, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35986865

RESUMO

Surgical procedures are often impeded by bleeding and/or leakage of body fluids. These complications cannot always be resolved by conventional surgical techniques. Hemopatch® is a hemostatic patch that also functions as a sealant. Here we document the effectiveness and safety of Hemopatch® for routine procedures of multiple surgical disciplines. To this end, we performed a prospective, multicenter, single-arm, observational registry study. Patients were eligible if they had received Hemopatch® during an open or minimally invasive procedure in one of these specialties: hepatobiliary, cardiovascular, urological, neurological/spinal, general, or lung surgery. Patients were excluded if they had a known hypersensitivity to bovine proteins or brilliant blue, intraoperative pulsatile or severe bleeding and/or infection at the target application site (TAS). The primary endpoint for intraoperative effectiveness was hemostasis assessed as the percentage of patients achieving hemostasis within 2 min and the percentage of patients achieving hemostasis without re-bleeding at the time of surgical closure. The registry enrolled 621 patients at 23 study sites in six European countries. Six hundred twenty patients had completed follow-up information. Hemostasis within 2 min was achieved at 463 (74.5%) of all 621 TASs. Hemostasis without re-bleeding was observed at 620 (99.8%) TASs. Adverse events were reported in 64 patients (10.3%). This Hemopatch® registry shows that Hemopatch® efficiently establishes hemostasis and sealing in a variety of surgical specialties, including minimally invasive procedures. Furthermore, we provide evidence for the safety of Hemopatch® across all the specialties included in the registry. This study is registered at clinicaltrials.gov: NCT03392662.


Assuntos
Hemostáticos , Especialidades Cirúrgicas , Animais , Perda Sanguínea Cirúrgica , Bovinos , Hemostasia Cirúrgica/métodos , Hemostáticos/efeitos adversos , Humanos , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento
19.
Surg Endosc ; 36(11): 8592-8599, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35931893

RESUMO

BACKGROUND: The very-low-voltage (VLV) mode in electrosurgery can stably and deeply energize tissues even if the local electrical resistance changes with energization. Therefore, in electrosurgical hemostasis, the VLV mode is more reliable than other coagulation modes. In clinical practice, the appropriate use of combined saline drip and blood suction under the VLV mode can further enhance coagulation ability. However, the detailed mechanism is not known. The current study aimed to evaluate the association between electrosurgical activation time (ET) and hemostatic tissue effect (HTE) under the VLV mode. Further, the effect of saline drip and suction on power consumption and HTE was validated. METHODS: Twelve female pigs weighing 35 kg were included in the experiment. A liver hemorrhage model was established via an open abdominal procedure, and hemostasis in the hemorrhagic lesion was attempted using the VLV mode under different conditions (ET: 3, 6, 9, and 12 s, with/without saline drip and/or continuous suction). Electrical data (such as voltage, current, and resistance) during coagulation were extracted. Then, the vertical/horizontal extent of HTE was assessed, and the hemostasis outcome (successful or failed) was recorded. RESULTS: The vertical/horizontal HTE, power consumption, and integrated current value were positively correlated with the ET. The coagulation depth deepened with saline drip (p < 0.01). However, it was not affected by continuous suction (p = 0.20). The HTE area increased with saline drip (p < 0.01) and decreased with suction (p < 0.01). The power consumption and integrated current increased with saline drip (p < 0.01) and decreased with suction (p < 0.01). The success rate of hemostasis decreased with saline drip alone (31of 48 trials [success rate = 64.5%] in the saline drip group and 44/48 trials (success rate = 91.7%) in the control group). However, it improved with continuous suction (46/48 trials [success rate = 95.8%]). CONCLUSION: The electrosurgical activation time was positively correlated with hemostatic tissue effect. Saline drip increased heat transfer efficiency but decreased the success rate of hemostasis. Therefore, the use of continuous suction in addition to saline drip increased hemostatic efficiency.


Assuntos
Diatermia , Hemostáticos , Feminino , Suínos , Animais , Eletrocoagulação/métodos , Eletrocirurgia/métodos , Hemostasia , Hemorragia , Hemostáticos/farmacologia , Hemostáticos/uso terapêutico , Hemostasia Cirúrgica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA