Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Scand J Pain ; 24(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38907689

RESUMO

OBJECTIVES: The purpose of this study was to investigate whether people with fibromyalgia (FM) have dysfunctional breathing by examining acid-base balance and comparing it with healthy controls. METHODS: Thirty-six women diagnosed with FM and 36 healthy controls matched for age and gender participated in this cross-sectional study. To evaluate acid-base balance, arterial blood was sampled from the radial artery. Carbon dioxide, oxygen, bicarbonate, base excess, pH and lactate were analysed for between-group differences. Blood gas analyses were performed stepwise on each individual to detect acid-base disturbance, which was categorized as primary respiratory and possible compensation indicating chronicity. A three-step approach was employed to evaluate pH, carbon dioxide and bicarbonate in this order. RESULTS: Women with FM had significantly lower carbon dioxide pressure (p = 0.013) and higher lactate (p = 0.038) compared to healthy controls at the group level. There were no significant differences in oxygen pressure, bicarbonate, pH and base excess. Employing a three-step acid-base analysis, 11 individuals in the FM group had a possible renally compensated mild chronic hyperventilation, compared to only 4 among the healthy controls (p = 0.042). CONCLUSIONS: In this study, we could identify a subgroup of individuals with FM who may be characterized as mild chronic hyperventilators. The results might point to a plausible dysfunctional breathing in some women with FM.


Assuntos
Fibromialgia , Hipocapnia , Humanos , Feminino , Fibromialgia/sangue , Fibromialgia/fisiopatologia , Estudos Transversais , Hipocapnia/sangue , Hipocapnia/fisiopatologia , Adulto , Pessoa de Meia-Idade , Ácido Láctico/sangue , Dióxido de Carbono/sangue , Equilíbrio Ácido-Base , Bicarbonatos/sangue , Gasometria , Estudos de Casos e Controles , Hiperventilação/sangue , Hiperventilação/fisiopatologia , Concentração de Íons de Hidrogênio
2.
Scand J Trauma Resusc Emerg Med ; 29(1): 35, 2021 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-33596977

RESUMO

BACKGROUND: ABGs are performed in acute conditions as the reference method for assessing the acid-base status of blood. Hyperventilation and breath-holding are common ventilatory changes that occur around the time of sampling, rapidly altering the 'true' status of the blood. This is particularly relevant in emergency medicine patients without permanent arterial catheters, where the pain and anxiety of arterial punctures can cause ventilatory changes. This study aimed to determine whether peripheral venous values could be a more reliable measure of blood gases following acute changes in ventilation. METHODS: To allow for characterisation of ventilatory changes typical of acutely ill patients, but without the confounding influence of perfusion or metabolic disturbances, 30 patients scheduled for elective surgery were studied in a prospective observational study. Following anaesthesia, and before the start of the surgery, ventilator settings were altered to achieve a + 100% or - 60% change in alveolar ventilation ('hyper-' or 'hypoventilation'), changes consistent with the anticipation of a painful arterial puncture commonly encountered in the emergency room. Blood samples were drawn simultaneously from indwelling arterial and peripheral venous catheters at baseline, and at 15, 30, 45, 60, 90 and 120 s following the ventilatory change. Comparisons between the timed arterial (or venous) samples were done using repeated-measures ANOVA, with post-hoc analysis using Bonferroni's correction. RESULTS: Arterial blood pH and PCO2 changed rapidly within the first 15-30s after both hyper- and hypoventilation, plateauing at around 60s (∆pH = ±0.036 and ∆PCO2 = ±0.64 kPa (4.7 mmHg), respectively), with peripheral venous values remaining relatively constant until 60s, and changing minimally thereafter. Mean arterial changes were significantly different at 30s (P < 0.001) when compared to baseline, in response to both hyper- and hypoventilation. CONCLUSION: This study has shown that substantial differences in arterial and peripheral venous acid-base status can be due to acute changes in ventilation, commonly seen in the ER over the 30s necessary to sample arterial blood. If changes are transient, peripheral venous blood may provide a more reliable description of acid-base status.


Assuntos
Equilíbrio Ácido-Base , Gasometria , Hiperventilação/sangue , Hipoventilação/sangue , Gasometria/métodos , Dióxido de Carbono/sangue , Feminino , Humanos , Concentração de Íons de Hidrogênio , Masculino , Estudos Prospectivos , Veias
3.
Exp Clin Transplant ; 16(6): 754-756, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30119620

RESUMO

An interaction between regained renal function in a transplanted kidney and hyperventilation syndrome may interfere with correct diagnosis of acid-base status in patients with preoperative nongap acidosis. Here, we present a patient with glomerular nephritis and hyperchloremia who underwent kidney transplant. Progressively increasing bicarbonate reabsorption by the renal graft, which thereby changed the arterial carbon dioxide tension-to-bicarbonate ratio, resulted in a time-sequence swing of an acid-base interpretation despite persistent mixed respiratory alkalosis due to hyperventilation syndrome and nongap metabolic acidosis due to preexisting hyperchloremia. Specifically, the sequence was mixed primary metabolic acidosis and primary respiratory acidosis immediately after surgery, primary metabolic acidosis and secondary respiratory alkalosis on postoperative days 1 and 2, mixed primary hyperchloremic metabolic acidosis and primary respiratory alkalosis on postoperative day 3, and finally primary respiratory alkalosis and secondary hyperchloremic metabolic acidosis on postoperative day 7. This swing in the acid-base interpretation indicates that the acid-base imbalance described here does not fit the empirical relationship for calculating the expected bicarbonate or carbon dioxide tension value, suggesting that "correct" interpretation of acid-base status may not lead to "correct" diagnosis of acid-base status. It should be remembered that not every acid-base imbalance fits the empirical relationship.


Assuntos
Equilíbrio Ácido-Base , Acidose/fisiopatologia , Alcalose Respiratória/fisiopatologia , Cloretos/sangue , Hiperventilação/fisiopatologia , Transplante de Rim/efeitos adversos , Rim/fisiopatologia , Rim/cirurgia , Acidose/sangue , Acidose/diagnóstico , Acidose/etiologia , Adulto , Alcalose Respiratória/sangue , Alcalose Respiratória/diagnóstico , Alcalose Respiratória/etiologia , Bicarbonatos/sangue , Biomarcadores/sangue , Humanos , Hiperventilação/sangue , Hiperventilação/diagnóstico , Hiperventilação/etiologia , Masculino , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Síndrome , Fatores de Tempo , Resultado do Tratamento
4.
Eur J Anaesthesiol ; 33(12): 929-935, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27802250

RESUMO

BACKGROUND: Near-infrared spectroscopy estimates cerebral regional tissue oxygen saturation (rSO2), which may decrease under hyperventilation. Propofol and sevoflurane act differently on cerebral blood vessels. Consequently, cerebral blood flow during hyperventilation with propofol and sevoflurane anaesthesia may differ. OBJECTIVES: The first aim of this study was to compare the changes in rSO2 between propofol and sevoflurane anaesthesia during hyperventilation. The second aim was to assess changes in rSO2 with ventilation changes. DESIGN: A randomised, open-label study. SETTING: University of Yamanashi Hospital, Yamanashi, Japan from January 2014 to September 2014. PARTICIPANTS: Fifty American Society of Anesthesiologists physical status 1 or 2 adult patients who were scheduled for elective abdominal surgery were assigned randomly to receive either propofol or sevoflurane anaesthesia. Exclusion criterion was a known history of cerebral disease such as cerebral infarction, cerebral haemorrhage, transient ischaemic attack and subarachnoid haemorrhage. INTERVENTIONS: After induction of anaesthesia but before the start of surgery, rSO2, arterial carbon dioxide partial pressure (PaCO2) and arterial oxygen saturation were measured. Measurements were repeated at 5-min intervals during 15 min of hyperventilation with a PaCO2 around 30 mmHg (4 kPa), and again after ventilation was normalised. MAIN OUTCOME MEASURES: The primary outcome was the difference of changes in rSO2 between propofol anaesthesia and sevoflurane anaesthesia during and after hyperventilation. The second outcome was change in rSO2 after the initiation of hyperventilation and after the normalisation of ventilation. RESULTS: Changes of rSO2 during hyperventilation were -10 ±â€Š7% (left) and -11 ±â€Š8% (right) in the propofol group, and -10 ±â€Š8% (left) and -9 ±â€Š7% (right) in the sevoflurane group. After normalisation of PaCO2, rSO2 returned to baseline values. Arterial oxygen saturation remained stable throughout the measurement period. The rSO2 values were similar in the propofol and the sevoflurane groups at each time point. CONCLUSION: The effects of hyperventilation on estimated rSO2 were similar with propofol and sevoflurane anaesthesia. Changes in rSO2 correlated well with ventilation changes. TRIAL REGISTRATION: Japan Primary Registries Network (JPRN); UMIN-CTR ID; UMIN000010640.


Assuntos
Hiperventilação/sangue , Éteres Metílicos/administração & dosagem , Oxigênio/sangue , Propofol/administração & dosagem , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Idoso , Anestésicos Inalatórios/administração & dosagem , Anestésicos Intravenosos/administração & dosagem , Feminino , Humanos , Hiperventilação/diagnóstico , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio/efeitos dos fármacos , Consumo de Oxigênio/fisiologia , Sevoflurano , Distribuição Tecidual/efeitos dos fármacos , Distribuição Tecidual/fisiologia
5.
Cutan Ocul Toxicol ; 34(4): 313-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25597376

RESUMO

OBJECTIVE: The purpose of this study was to examine the vasoreactivity in retina and choroid of the healthy eyes in response to experimentally altered partial arterial pressure of carbon dioxide (PaCO(2)) using a non-invasive technique, spectral domain optical coherence tomography (SD-OCT). MATERIALS AND METHODS: The study included non-smoking participants between 18 and 35 years of age, having visual acuity of 20/20 and with no systemic and ocular diseases. At baseline, the participants breathed room air (normocapnia). Hypocapnia was created with the help of hyperventilation; for this, the participants were instructed to draw deep and quick breaths, resulting one breathing cycle per 2 s. To create hypercapnia subjects rebreathed from a 5 l bag at least 3 min. Choroidal thickness and retinal artery diameter were measured at baseline, and hyperventilation and rebreathing conditions by SD-OCT. RESULTS: Twenty eyes of 20 healthy subjects were included in this study. Their mean age was 24.90 ± 5.32 years. Hyperventilation caused a significant reduction in choroidal thickness, compared with baseline, at all points; whereas rebreathing caused no significant change at all points. The mean diameters of the arteries were 151.80 ± 7.88 µm, with a significant decline to 148.90 ± 7.25 µm at hyperventilation condition and a significant increase to 153.50 ± 7.88 µm at rebreathing condition (p = 0.018, p = 0.043, respectively). CONCLUSION: This study demonstrated that, SD-OCT was a useful tool in measuring the ocular vascular response under hypercapnia and hypocapnia conditions. These findings may be helpful for further understanding the physiological nature of ocular blood flow and this preliminary study provides a basis for future studies.


Assuntos
Dióxido de Carbono/sangue , Corioide/irrigação sanguínea , Hiperventilação/fisiopatologia , Respiração , Vasos Retinianos/anatomia & histologia , Adolescente , Adulto , Corioide/anatomia & histologia , Feminino , Humanos , Hipercapnia/sangue , Hipercapnia/fisiopatologia , Hiperventilação/sangue , Hipocapnia/sangue , Hipocapnia/fisiopatologia , Masculino , Pressão Parcial , Estudos Prospectivos , Tomografia de Coerência Óptica , Vasoconstrição/fisiologia , Vasodilatação/fisiologia , Adulto Jovem
6.
J Appl Physiol (1985) ; 115(8): 1107-18, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-23869066

RESUMO

The mismatching of alveolar ventilation and perfusion (VA/Q) is the major determinant of impaired gas exchange. The gold standard for measuring VA/Q distributions is based on measurements of the elimination and retention of infused inert gases. Conventional multiple inert gas elimination technique (MIGET) uses gas chromatography (GC) to measure the inert gas partial pressures, which requires tonometry of blood samples with a gas that can then be injected into the chromatograph. The method is laborious and requires meticulous care. A new technique based on micropore membrane inlet mass spectrometry (MMIMS) facilitates the handling of blood and gas samples and provides nearly real-time analysis. In this study we compared MIGET by GC and MMIMS in 10 piglets: 1) 3 with healthy lungs; 2) 4 with oleic acid injury; and 3) 3 with isolated left lower lobe ventilation. The different protocols ensured a large range of normal and abnormal VA/Q distributions. Eight inert gases (SF6, krypton, ethane, cyclopropane, desflurane, enflurane, diethyl ether, and acetone) were infused; six of these gases were measured with MMIMS, and six were measured with GC. We found close agreement of retention and excretion of the gases and the constructed VA/Q distributions between GC and MMIMS, and predicted PaO2 from both methods compared well with measured PaO2. VA/Q by GC produced more widely dispersed modes than MMIMS, explained in part by differences in the algorithms used to calculate VA/Q distributions. In conclusion, MMIMS enables faster measurement of VA/Q, is less demanding than GC, and produces comparable results.


Assuntos
Cromatografia Gasosa , Cromatografia Gasosa-Espectrometria de Massas , Membranas Artificiais , Filtros Microporos , Gases Nobres/sangue , Ventilação Pulmonar , Relação Ventilação-Perfusão , Animais , Animais Recém-Nascidos , Calibragem , Cromatografia Gasosa/normas , Modelos Animais de Doenças , Desenho de Equipamento , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Gasosa-Espectrometria de Massas/normas , Hiperventilação/sangue , Hiperventilação/etiologia , Hiperventilação/fisiopatologia , Lesão Pulmonar/sangue , Lesão Pulmonar/induzido quimicamente , Lesão Pulmonar/fisiopatologia , Manometria , Ácido Oleico , Pressão Parcial , Porosidade , Circulação Pulmonar , Troca Gasosa Pulmonar , Padrões de Referência , Respiração Artificial , Suínos , Fatores de Tempo
8.
Acta Med Okayama ; 67(2): 99-104, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23603926

RESUMO

Patients undergoing a panic attack (PA) or a hyperventilation attack (HVA) are sometimes admitted to emergency departments (EDs). Reduced serotonin level is known as one of the causes of PA and HVA. Serotonin is synthesized from tryptophan. For the synthesis of serotonin, vitamin B6 (Vit B6) and iron play important roles as cofactors. To clarify the pathophysiology of PA and HVA, we investigated the serum levels of vitamins B2, B6, and B12 and iron in patients with PA or HVA attending an ED. We measured each parameter in 21 PA or HVA patients and compared the values with those from 20 volunteers. We found that both Vit B6 and iron levels were significantly lower in the PA/HVA group than in the volunteer group. There was no significant difference in the serum levels of vitamins B2 or B12. These results suggest that low serum concentrations of Vit B6 and iron are involved in PA and HVA. Further studies are needed to clarify the mechanisms involved in such differences.


Assuntos
Anemia Ferropriva/complicações , Hiperventilação/etiologia , Ferro/sangue , Transtorno de Pânico/etiologia , Deficiência de Vitamina B 6/complicações , Vitamina B 6/sangue , Adulto , Anemia Ferropriva/sangue , Feminino , Hemoglobinas/metabolismo , Humanos , Hiperventilação/sangue , Análise Multivariada , Transtorno de Pânico/sangue , Riboflavina/sangue , Serotonina/metabolismo , Vitamina B 12/sangue , Deficiência de Vitamina B 6/sangue , Adulto Jovem
9.
J Anesth ; 27(5): 712-9, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23612881

RESUMO

PURPOSE: Mild hypercapnia with hyperventilation has been reported to significantly decrease recovery time from inhaled anesthesia in young and middle-aged patients. However, its efficacy has not yet been clarified in elderly patients, although delayed emergence can deteriorate their quality of recovery. METHODS: We enrolled 30 elderly patients (≥65 years) and 30 middle-aged patients (45-64 years) who were scheduled for ophthalmic surgery and allocated them to the control or the device group. Anesthesia was maintained with 1.5% sevoflurane. Mild hypercapnic hyperventilation was induced by the ANEclear anesthesia recovery device. The primary outcome was the time from vaporizer shut-off to initial response (eye or mouth opening, nodding, or grasping hand) in elderly patients. The secondary outcomes were the time to extubation and leaving the operating room (OR), the time to reach 50% of the difference between BIS at extubation and vaporizer shut-off (BIS ET50), and interaction between the recovery measures and patient age. RESULTS: The ANEclear significantly reduced the time to initial response, extubation, leaving the OR, and BIS ET50 in both age groups: their means and 95% CI of the ratio of two means (Mean(ANEclear)/Mean(control)) were 0.576 (0.500, 0.660), 0.595 (0.523, 0.673), 0.713 (0.622, 0.812), and 0.547 (0.444, 0.663), respectively, in the elderly group, and 0.717 (0.591, 0.849), 0.723 (0.609, 0.842), 0.855 (0.736, 0.982), and 0.631 (0.463, 0.813), respectively, in the middle-aged group. The recovery measures were shortened equally in both age groups: P values for the interaction were 0.060679, 0.062534, 0.069215, and 0.420061, respectively. CONCLUSIONS: Recovery time was significantly decreased by the ANEclear in the elderly group. This reduction was comparable to the time for middle-aged patients.


Assuntos
Período de Recuperação da Anestesia , Anestésicos Inalatórios/administração & dosagem , Hipercapnia/fisiopatologia , Hiperventilação/sangue , Idoso , Feminino , Humanos , Hipercapnia/sangue , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA