Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Neuroimage ; 237: 118175, 2021 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-34000407

RESUMO

PURPOSE: Susceptibility Weighted Imaging (SWI) has become established in the clinical investigation of stroke, microbleeds, tumor vascularization, calcification and iron deposition, but suffers from a number of shortcomings and artefacts. The goal of this study was to reduce the sensitivity of SWI to strong B1 and B0 inhomogeneities at ultra-high field to generate homogeneous images with increased contrast and free of common artefacts. All steps in SWI processing have been addressed - coil combination, phase unwrapping, image combination over echoes, phase filtering and homogeneity correction - and applied to an efficient bipolar multi-echo acquisition to substantially improve the quality of SWI. PRINCIPAL RESULTS: Our findings regarding the optimal individual processing steps lead us to propose a Contrast-weighted, Laplace-unwrapped, bipolar multi-Echo, ASPIRE-combined, homogeneous, improved Resolution SWI, or CLEAR-SWI. CLEAR-SWI was compared to two other multi-echo SWI methods and standard, single-echo SWI with the same acquisition time at 7 T in 10 healthy volunteers and with single-echo SWI in 13 patients with brain tumors. CLEAR-SWI had improved contrast-to-noise and homogeneity, reduced signal dropout and was not compromised by the artefacts which affected standard SWI in 10 out of 13 cases close to tumors (as assessed by expert raters), as well as generating T2* maps and phase images which can be used for Quantitative Susceptibility Mapping. In a comparison with other multi-echo SWI methods, CLEAR-SWI had the fewest artefacts, highest SNR and generally higher contrast-to-noise. MAJOR CONCLUSIONS: CLEAR-SWI eliminates the artefacts common in standard, single-echo SWI, reduces signal dropouts and improves image homogeneity and contrast-to-noise. Applied clinically, in a study of brain tumor patients, CLEAR-SWI was free of the artefacts which affected standard, single-echo SWI.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Imagem Ecoplanar/normas , Processamento de Imagem Assistida por Computador/normas , Neuroimagem/normas , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
2.
Hum Brain Mapp ; 42(13): 4144-4154, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-30761676

RESUMO

Advanced perfusion-weighted imaging (PWI) methods that combine gradient echo (GE) and spin echo (SE) data are important tools for the study of brain tumours. In PWI, single-shot, EPI-based methods have been widely used due to their relatively high imaging speed. However, when used with increasing spatial resolution, single-shot EPI methods often show limitations in whole-brain coverage for multi-contrast applications. To overcome this limitation, this work employs a new version of EPI with keyhole (EPIK) to provide five echoes: two with GEs, two with mixed GESE and one with SE; the sequence is termed "GESE-EPIK." The performance of GESE-EPIK is evaluated against its nearest relative, EPI, in terms of the temporal signal-to-noise ratio (tSNR). Here, data from brain tumour patients were acquired using a hybrid 3T MR-BrainPET scanner. GESE-EPIK resulted in reduced susceptibility artefacts, shorter TEs for the five echoes and increased brain coverage when compared to EPI. Moreover, compared to EPI, EPIK achieved a comparable tSNR for the first and second echoes and significantly higher tSNR for other echoes. A new method to obtain multi-echo GE and SE data with shorter TEs and increased brain coverage is demonstrated. As proposed here, the workflow can be shortened and the integration of multimodal clinical MR-PET studies can be facilitated.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Imagem Ecoplanar , Processamento de Imagem Assistida por Computador , Imagem de Perfusão , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Humanos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/normas , Imagem Multimodal/métodos , Imagem Multimodal/normas , Imagem de Perfusão/métodos , Imagem de Perfusão/normas , Tomografia por Emissão de Pósitrons/métodos , Tomografia por Emissão de Pósitrons/normas
3.
Cancer Imaging ; 20(1): 66, 2020 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-32958041

RESUMO

BACKGROUND: We assessed the image quality of endometrial cancer lesions by readout segmentation of long variable echo-trains (RESOLVE) diffusion-weighted imaging (DWI) compared with that by single-shot echo-planar imaging (SS-EPI) DWI, aimed to explore the value of RESOLVE DWI for determining myometrial invasion and clinical stage in endometrial cancer. MATERIALS AND METHODS: From April 2017 to March 2018, a total of 30 endometrial cancer patients (mean age 52.8 ± 9.0 years), who had undergone RESOLVE DWI and SS-EPI DWI, were included in the study. The image quality of endometrial carcinoma by two kinds of DWI scanning methods was compared qualitatively and quantitatively. The Spearman rank correlation test was used to assess the correlation of qualitative image quality scores between two readers. The accuracy of two DWI methods in detecting myometrial invasion and staging of endometrial carcinoma was calculated according to postoperative pathological results. The indexes were analyzed including sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV). RESULTS: The qualitative score of RESOLVE DWI group was superior to SS-EPI DWI group in every aspect of five aspects (all P < 0.001). Interobserver agreement of depiction was good or excellent in two DWI sequences. Signal to noise ratio and contrast to noise ratio values in RESOLVE DWI group were both higher than those in SS-EPI DWI group (P<0.001). No statistical difference of apparent diffusion coefficient value was observed between two DWI groups (P = 0.261). The specificity, accuracy, PPV, and NPV of estimating myometrial invasion by RESOLVE DWI in three cases (intramucosal lesion, <50% superficial invasion and ≥ 50% deep invasion) were all higher than those by SS-EPI DWI for endometrial carcinoma. Especially RESOLVE DWI was valuable in judging <50% superficial invasion (95%CI:0.586, 0.970). No significant difference in accuracy staging was between the two DWI groups (P = 0.125). CONCLUSION: RESOLVE DWI can provide higher quality images of endometrial carcinoma than SS-EPI DWI. The high-quality images are helpful for precise assessment of myometrial invasion in endometrial cancer.


Assuntos
Carcinoma/diagnóstico por imagem , Imagem Ecoplanar/métodos , Neoplasias do Endométrio/diagnóstico por imagem , Miométrio/diagnóstico por imagem , Adulto , Idoso , Carcinoma/patologia , Imagem Ecoplanar/normas , Neoplasias do Endométrio/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Miométrio/patologia , Invasividade Neoplásica , Razão Sinal-Ruído
4.
Hum Brain Mapp ; 41(3): 797-814, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31692177

RESUMO

Resting-state functional magnetic resonance imaging (rsfMRI) is a promising task-free functional imaging approach, which may complement or replace task-based fMRI (tfMRI) in patients who have difficulties performing required tasks. However, rsfMRI is highly sensitive to head movement and physiological noise, and validation relative to tfMRI and intraoperative electrocortical mapping is still necessary. In this study, we investigate (a) the feasibility of real-time rsfMRI for presurgical mapping of eloquent networks with monitoring of data quality in patients with brain tumors and (b) rsfMRI localization of eloquent cortex compared with tfMRI and intraoperative electrocortical stimulation (ECS) in retrospective analysis. Five brain tumor patients were studied with rsfMRI and tfMRI on a clinical 3T scanner using MultiBand(8)-echo planar imaging (EPI) with repetition time: 400 ms. Moving-averaged sliding-window correlation analysis with regression of motion parameters and signals from white matter and cerebrospinal fluid was used to map sensorimotor and language resting-state networks. Data quality monitoring enabled rapid optimization of scan protocols, early identification of task noncompliance, and head movement-related false-positive connectivity to determine scan continuation or repetition. Sensorimotor and language resting-state networks were identifiable within 1 min of scan time. The Euclidean distance between ECS and rsfMRI connectivity and task-activation in motor cortex, Broca's, and Wernicke's areas was 5-10 mm, with the exception of discordant rsfMRI and ECS localization of Wernicke's area in one patient due to possible cortical reorganization and/or altered neurovascular coupling. This study demonstrates the potential of real-time high-speed rsfMRI for presurgical mapping of eloquent cortex with real-time data quality control, and clinically acceptable concordance of rsfMRI with tfMRI and ECS localization.


Assuntos
Mapeamento Encefálico/normas , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Córtex Cerebral/diagnóstico por imagem , Imagem de Tensor de Difusão/normas , Imagem Ecoplanar/normas , Eletrocorticografia/normas , Rede Nervosa/diagnóstico por imagem , Cuidados Pré-Operatórios , Adulto , Mapeamento Encefálico/métodos , Córtex Cerebral/fisiologia , Imagem de Tensor de Difusão/métodos , Imagem Ecoplanar/métodos , Estimulação Elétrica/métodos , Eletrocorticografia/métodos , Estudos de Viabilidade , Feminino , Humanos , Monitorização Neurofisiológica Intraoperatória/métodos , Monitorização Neurofisiológica Intraoperatória/normas , Idioma , Masculino , Pessoa de Meia-Idade , Rede Nervosa/fisiologia , Córtex Sensório-Motor/diagnóstico por imagem , Córtex Sensório-Motor/fisiologia
5.
Cancer Imaging ; 19(1): 59, 2019 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-31455403

RESUMO

BACKGROUND: To evaluate whether readout-segment echo-planar imaging (RS-EPI) can provide better image quality in assessing bladder cancer than single-shot echo-planar imaging (SS-EPI) and to compare quantitative imaging parameters derived from both techniques. METHODS: Seventy patients with bladder lesions were enrolled and underwent diffusion-weighted imaging on a 3 Tesla magnetic resonance scanner using axial RS-EPI and SS-EPI techniques. Two observers independently assessed the susceptibility, detectability, motion artefacts and blurring of the images using qualitative scores. The signal-to-noise ratio (SNR), signal intensity ratio (SIR), contrast-to-noise ratio (CNR) and ADC values of the bladder lesions were measured and compared between the two techniques and between two observers. Qualitative and quantitative comparisons of image quality were performed using the Wilcoxon signed-rank test and paired t-test. In addition, the agreement of the ADC measurements was evaluated using ICC values and Bland-Altman plots. RESULTS: Sixty-eight patients were included in the final analysis. The scores of image susceptibility, detectability and blurring for RS-EPI were significantly higher than those for SS-EPI (all p < 0.05), while the motion artefact was not. There were significant differences between RS-EPI and SS-EPI in the CNR and SIR values (all p < 0.05) but not in the SNR or ADC values (all p > 0.05). The ICC values and Bland-Altman plots also showed excellent agreement between the measured ADC values of the bladder lesions. CONCLUSIONS: The RS-EPI technique provides significantly better image quality in patients with bladder cancer than the SS-EPI technique, without a significant difference in the ADC value.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Adulto , Idoso , Imagem de Difusão por Ressonância Magnética/normas , Imagem Ecoplanar/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão Sinal-Ruído
6.
World J Gastroenterol ; 25(3): 308-329, 2019 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-30686900

RESUMO

Elastography-based liver stiffness measurement (LSM) is a non-invasive tool for estimating liver fibrosis but also provides an estimate for the severity of portal hypertension in patients with advanced chronic liver disease (ACLD). The presence of varices and especially of varices needing treatment (VNT) indicates distinct prognostic stages in patients with compensated ACLD (cACLD). The Baveno VI guidelines suggested a simple algorithm based on LSM < 20 kPa (by transient elastography, TE) and platelet count > 150 G/L for ruling-out VNT in patients with cACLD. These (and other) TE-based LSM cut-offs have been evaluated for VNT screening in different liver disease etiologies. Novel point shear-wave elastography (pSWE) and two-dimensional shear wave elastography (2D-SWE) methodologies for LSM have also been evaluated for their ability to screen for "any" varices and for VNT. Finally, the measurement of spleen stiffness (SSM) by elastography (mainly by pSWE and 2D-SWE) may represent another valuable screening tool for varices. Here, we summarize the current literature on elastography-based prediction of "any" varices and VNT. Finally, we have summarized the published LSM and SSM cut-offs in clinically useful scale cards.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Varizes Esofágicas e Gástricas/diagnóstico , Hipertensão Portal/diagnóstico , Cirrose Hepática/complicações , Fígado/diagnóstico por imagem , Protocolos Clínicos/normas , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Técnicas de Imagem por Elasticidade/normas , Varizes Esofágicas e Gástricas/etiologia , Humanos , Hipertensão Portal/etiologia , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Programas de Rastreamento/métodos , Programas de Rastreamento/normas , Guias de Prática Clínica como Assunto , Prognóstico
7.
Cancer Imaging ; 18(1): 21, 2018 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-29784058

RESUMO

BACKGROUND: To investigate the application value of fat-suppressed gadolinium-enhanced isotropic high-resolution 3D-GRE-T1WI in regional nodes with different short-axis diameter ranges in rectal cancer, especially in nodes ≤5 mm. METHODS: Patients with rectal adenocarcinoma confirmed by postoperative histopathology were included, and all the patients underwent preoperative 3.0 T rectal magnetic resonance imaging (MRI) and total mesorectal excision (TME) within 2 weeks after an MR scan. The harvested nodes from specimens were matched with nodes in the field of view (FOV) of images for a node-by-node evaluation. The maximum short-axis diameters of all the visible nodes in the FOV of images were measured by a radiologist; the morphological and enhancement characteristics of these nodes were also independently evaluated by two radiologists. The χ 2 test was used to evaluate differences in morphological and enhancement characteristics between benign and malignant nodes. The enhancement characteristics were further compared between benign and malignant nodes with different short-axis diameter ranges using the χ 2 test. Kappa statistics were used to describe interobserver agreement. RESULTS: A total of 441 nodes from 70 enrolled patients were included in the evaluation, of which 111 nodes were metastatic. Approximately 85.5 and 95.6% of benign nodes were found to have obvious enhancement and homogeneous or mild-heterogeneous enhancement, respectively, whereas approximately 89.2 and 85.1% of malignant nodes showed moderate or mild enhancement and obvious-heterogeneous or rim-like enhancement, respectively. The area under the receiver operating characteristic (ROC) curve (AUC) values of the enhancement degree for identifying the overall nodal status, nodes ≤5 mm and nodes > 5 mm and ≤ 10 mm were 0.887, 0.859 and 0.766 for radiologist 1 and 0.892, 0.823 and 0.774 for radiologist 2, respectively. The AUCs of enhancement homogeneity were 0.940, 0.928 and 0.864 for radiologist 1 and 0.944, 0.938 and 0.842 for radiologist 2, respectively. Nodal border and signal homogeneity were also of certain value in distinguishing metastatic nodes. CONCLUSIONS: Enhancement characteristics based on fat-suppressed gadolinium-enhanced isotropic high-resolution 3D-GRE-T1WI were helpful for diagnosing metastatic nodes in rectal cancer and were a reliable indicator for nodes ≤5 mm.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Imagem Ecoplanar/métodos , Gadolínio/administração & dosagem , Neoplasias Retais/diagnóstico por imagem , Adenocarcinoma/patologia , Adulto , Idoso , Imagem Ecoplanar/normas , Feminino , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Neoplasias Retais/patologia , Sensibilidade e Especificidade
8.
Eur J Radiol ; 102: 213-219, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29685538

RESUMO

OBJECTIVE: To compare image quality, artefact, and distortion in standard echo-planar imaging (EPI) with periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) for prostate magnetic resonance imaging (MRI) diffusion-weighted imaging (DWI) in patients with previous total hip replacement (THR). METHODS: 21 male subjects with a clinical suspicion for, or known prostate cancer and previous THR were scanned at 1.5 T using a phased-array body coil. DWI was obtained using single-shot EPI and PROPELLER techniques using fat saturation (PROPELLER-DWI-FS), and without (PROPELLER-DWI-NFS). Image quality (the overall impression of diagnostic quality) was compared to T2-weighted (T2WI) imaging using a 5-point Likert scale, with diffusion sequences additionally scored for artefact and distortion according to a 4-point scale, with artefact defined as the amount of prostate affected and distortion as the degree of warping of the organ. The T2W and DW image volumes were compared to produce quantitative distortion maps. A two-sample Wilcoxon test compared the qualitative scores, with inter-reader variability calculated using Cohen's kappa. RESULTS: 21 patients were included in the study, with an average age of 70.4 years and PSA 9.2 ng/ml. Hip metalwork was present bilaterally in 3 patients, left-sided in 9, and right-sided in 9. PROPELLER-DWI-FS significantly improved image quality (p < 0.01) and reduced distortion (p < 0.01) when compared to standard EP-DWI. Artefact was not shown to be significantly improved. The last 5 patients in the study were additionally imaged with PROPELLER-DWI-NFS, which resulted in a significant reduction in artefact compared to EP-DWI (p < 0.05). Quantitative distortion was significantly lower compared to EP-DWI for both PROPELLER with fat saturation (p < 0.01) and without fat saturation (p < 0.01). CONCLUSION: PROPELLER-DWI demonstrates better image quality and decreases both artefact and distortion compared to conventional echo planar sequences in patients with hip metalwork.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Neoplasias da Próstata/patologia , Idoso , Idoso de 80 Anos ou mais , Artefatos , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/normas , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
Neuroimage ; 168: 490-498, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28027961

RESUMO

Presurgical planning with fMRI benefits from increased reliability and the possibility to reduce measurement time introduced by using ultra-high field. Echo-planar imaging suffers, however, from geometric distortions which scale with field strength and potentially give rise to clinically significant displacement of functional activation. We evaluate the effectiveness of a dynamic distortion correction (DDC) method based on unmodified single-echo EPI in the context of simulated presurgical planning fMRI at 7T and compare it with static distortion correction (SDC). The extent of distortion in EPI and activation shifts are investigated in a group of eleven patients with a range of neuropathologies who performed a motor task. The consequences of neglecting to correct images for susceptibility-induced distortions are assessed in a clinical context. It was possible to generate time series of EPI-based field maps which were free of artifacts in the eloquent brain areas relevant to presurgical fMRI, despite the presence of signal dropouts caused by pathologies and post-operative sites. Distortions of up to 5.1mm were observed in the primary motor cortex in raw EPI. These were accurately corrected with DDC and slightly less accurately with SDC. The dynamic nature of distortions in UHF clinical fMRI was demonstrated via investigation of temporal variation in voxel shift maps, confirming the potential inadequacy of SDC based on a single reference field map, particularly in the vicinity of pathologies or in the presence of motion. In two patients, the distortion correction was potentially clinically significant in that it might have affected the localization or interpretation of activation and could thereby have influenced the treatment plan. Distortion correction is shown to be effective and clinically relevant in presurgical planning at 7T.


Assuntos
Mapeamento Encefálico/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Transtornos Cerebrovasculares/diagnóstico por imagem , Imagem Ecoplanar/métodos , Processamento de Imagem Assistida por Computador/métodos , Córtex Motor/diagnóstico por imagem , Adulto , Artefatos , Mapeamento Encefálico/normas , Neoplasias Encefálicas/cirurgia , Transtornos Cerebrovasculares/cirurgia , Imagem Ecoplanar/normas , Feminino , Humanos , Processamento de Imagem Assistida por Computador/normas , Masculino , Pessoa de Meia-Idade , Córtex Motor/fisiologia , Procedimentos Neurocirúrgicos , Cuidados Pré-Operatórios
10.
BMC Cancer ; 15: 167, 2015 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-25885786

RESUMO

BACKGROUND: There are currently three ongoing studies on less radical surgery in cervical cancer: ConCerv, GOG-278, and SHAPE. The aim of this study was to evaluate the performance of the criteria used in ongoing studies retrospectively and suggest a new, simplified criterion in microscopic Stage IB1 cervical cancer. METHODS: A retrospective analysis was performed in 125 Stage IB1 cervical cancer patients who had no clinically visible lesions and were allotted based on microscopic findings after conization. All patients had magnetic resonance imaging (MRI) after conization and underwent type C2 radical hysterectomy. We suggested an MRI criterion for less radical surgery candidates as patients who had no demonstrable lesions on MRI. The rates of parametrial involvement (PMI) were estimated for patients that satisfied the inclusion criteria for ongoing studies and the MRI criterion. RESULTS: The rate of pathologic PMI was 5.6% (7/125) in the study population. ConCerv and GOG-278 identified 11 (8.8%) and 14 (11.2%) patients, respectively, as less radical surgery candidates, and there were no false negative cases. SHAPE and MRI criteria identified 78 (62.4%) and 74 (59.2%) patients, respectively, as less radical surgery candidates; 67 patients were identified as less radical surgery candidates by both sets of criteria. Of these 67 patients, only one had pathologic PMI with tumor emboli. CONCLUSIONS: This study suggests that the criteria used in three ongoing studies and a new, simplified criterion using MRI can identify candidates for less radical surgery with acceptable false negativity in microscopic Stage IB1 disease.


Assuntos
Imagem Ecoplanar/métodos , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Imagem Ecoplanar/normas , Feminino , Humanos , Microscopia/métodos , Microscopia/normas , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
11.
Clin Cancer Res ; 21(19): 4373-83, 2015 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-25901082

RESUMO

PURPOSE: Evaluation of nonenhancing tumor (NET) burden is an important yet challenging part of brain tumor response assessment. This study focuses on using dual-echo turbo spin-echo MRI as a means of quickly estimating tissue T2, which can be used to objectively define NET burden. EXPERIMENTAL DESIGN: A series of experiments were performed to establish the use of T2 maps for defining NET burden. First, variation in T2 was determined using the American College of Radiology (ACR) water phantoms in 16 scanners evaluated over 3 years. Next, the sensitivity and specificity of T2 maps for delineating NET from other tissues were examined. Then, T2-defined NET was used to predict survival in separate subsets of patients with glioblastoma treated with radiotherapy, concurrent radiation, and chemotherapy, or bevacizumab at recurrence. RESULTS: Variability in T2 in the ACR phantom was 3% to 5%. In training data, ROC analysis suggested that 125 ms < T2 < 250 ms could delineate NET with a sensitivity of >90% and specificity of >65%. Using this criterion, NET burden after completion of radiotherapy alone, or concurrent radiotherapy, and chemotherapy was shown to be predictive of survival (Cox, P < 0.05), and the change in NET volume before and after bevacizumab therapy in recurrent glioblastoma was also a predictive of survival (P < 0.05). CONCLUSIONS: T2 maps using dual-echo data are feasible, stable, and can be used to objectively define NET burden for use in brain tumor characterization, prognosis, and response assessment. The use of effective T2 maps for defining NET burden should be validated in a randomized, clinical trial.


Assuntos
Neoplasias Encefálicas/diagnóstico , Imagem Ecoplanar , Glioma/diagnóstico , Adulto , Idoso , Neoplasias Encefálicas/mortalidade , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/terapia , Quimiorradioterapia , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Feminino , Glioma/mortalidade , Glioma/patologia , Glioma/terapia , Humanos , Estimativa de Kaplan-Meier , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento , Carga Tumoral , Adulto Jovem
12.
Korean J Radiol ; 15(4): 403-10, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25053898

RESUMO

OBJECTIVE: The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. MATERIALS AND METHODS: Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. RESULTS: The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. CONCLUSION: Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast.


Assuntos
Imagem de Difusão por Ressonância Magnética/normas , Imagem Ecoplanar/normas , Aumento da Imagem/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Mama/patologia , Neoplasias da Mama/patologia , Meios de Contraste , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
13.
Invest Radiol ; 47(6): 368-75, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22543969

RESUMO

OBJECTIVE: The aims of this study were to assess the confounding effects of hepatic iron deposition, inflammation, and fibrosis on hepatic steatosis (HS) evaluation by magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) and to assess the accuracies of MRI and MRS for HS evaluation, using histology as the reference standard. MATERIALS AND METHODS: In this institutional review board-approved prospective study, 56 patients gave informed consents and underwent chemical-shift MRI and MRS of the liver on a 1.5-T magnetic resonance scanner. To estimate MRI fat fraction (FF), 4 analysis methods were used (dual-echo, triple-echo, multiecho, and multi-interference), and MRS FF was calculated with T2 correction. Degrees of HS, iron deposition, inflammation, and fibrosis were analyzed in liver resection (n = 37) and biopsy (n = 19) specimens. The confounding effects of histology on fat quantification were assessed by multiple linear regression analysis. Using the histologic degree of HS as the reference standard, the accuracies of each method in estimating HS and diagnosing an HS of 5% or greater were determined by linear regression and receiver operating characteristic analyses. RESULTS: Iron deposition significantly confounded estimations of FF by the dual-echo (P < 0.001) and triple-echo (P = 0.033) methods, whereas no histologic feature confounded the multiecho and multi-interference methods or MRS. The MRS (r = 0.95) showed the strongest correlation with histologic degree of HS, followed by the multiecho (r = 0.92), multi-interference (r = 0.91), triple-echo (r = 0.90), and dual-echo (r = 0.85) methods. For diagnosing HS, the areas under the curve tended to be higher for MRS (0.96) and the multiecho (0.95), multi-interference (0.95), and triple-echo (0.95) methods than for the dual-echo method (0.88) (P ≥ 0.13). CONCLUSION: The multiecho and multi-interference MRI methods and MRS can accurately quantify hepatic fat, with coexisting histologic abnormalities having no confounding effects.


Assuntos
Adiposidade , Imagem Ecoplanar/métodos , Fígado Gorduroso/diagnóstico , Fígado Gorduroso/metabolismo , Ferro/análise , Espectroscopia de Ressonância Magnética/métodos , Tecido Adiposo , Adulto , Idoso , Imagem Ecoplanar/normas , Feminino , Humanos , Fígado , Masculino , Pessoa de Meia-Idade , Valores de Referência , República da Coreia
14.
AJNR Am J Neuroradiol ; 32(7): 1173-7, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21659484

RESUMO

BACKGROUND AND PURPOSE: 2D-ss-IMIV-DWEPI is an ss-DWEPI with greatly reduced geometric distortion. The purposes of this paper are to 1) evaluate of the utility of 2D-ss-IMIV-DWEPI for high-resolution neck LN imaging; 2) determine whether 2D-ss-IMIV-DWEPI can depict normal LN hilum; and 3) evaluate whether the inclusion of LN hilum within ROIs affects the measured LN ADC. MATERIALS AND METHODS: HR-DWI was acquired with 1-mm² in-plane resolution and 2-mm section thickness by using 2D-ss-IMIV-DWEPI. In total, 58 LNs from 18 subjects were evaluated. The ADC map was calculated by using DWI with b = 10 and 300 s/mm². In those LNs where the LN hilum could be recognized, the LN ADC was measured with and without inclusion of the hilum, and the mean difference of the resulting ADC values was determined. RESULTS: The hilar structure was identified by DWI in 15 LNs. The ADC of the hilum was 1.981 ± 0.331 × 10⁻³ mm²/s. In these 15 LNs, the ADC value excluding hilar structure was significantly lower than the ADC value including hilar structure (0.983 ± 0.169 versus 1.206 ± 0.244 × 10⁻³ mm²/s; P < .0001). The mean ADC in a total of 58 LNs excluding the hilar structure was significantly lower than the value obtained including the hilar structure (1.034 ± 0.183 versus 1.095 ± 0.213 × 10⁻³ mm²/s; P = .0002). CONCLUSIONS: HR-DWI of neck LNs obtained by using 2D-ss-IMIV-DWEPI could identify the hilar structure. The ADC of normal neck LNs seemed significantly different when the hilum was included. The results suggest that HR-DWI may be helpful to aid selection of proper ROIs within LNs for accurate and reliable ADC measurements.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/normas , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Linfonodos/anatomia & histologia , Pescoço/anatomia & histologia , Idoso , Idoso de 80 Anos ou mais , Artefatos , Carcinoma de Células Escamosas/secundário , Doenças das Artérias Carótidas/patologia , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Metástase Linfática , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes
15.
AJNR Am J Neuroradiol ; 32(7): 1274-9, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21596809

RESUMO

BACKGROUND AND PURPOSE: RS-EPI has been suggested as an alternative approach to EPI for high-resolution DWI with reduced distortions. To determine whether RS-EPI is a useful approach for routine clinical use, we implemented GRAPPA-accelerated RS-EPI DWI at our pediatric hospital and graded the images alongside standard accelerated (ASSET) EPI DWI used routinely for clinical studies. MATERIALS AND METHODS: GRAPPA-accelerated RS-EPI DWIs and ASSET EPI DWIs were acquired on 35 pediatric patients using a 3T system in 35 pediatric patients. The images were graded alongside each other by using a 7-point Likert scale as follows: 1, nondiagnostic; 2, poor; 3, acceptable; 4, standard; 5, above average; 6, good; and 7, outstanding. RESULTS: The following were the average scores for EPI and RS-EPI, respectively: resolution, 3.5/5.2; distortion level, 2.9/6.0; SNR, 3.4/4.1; lesion conspicuity, 3.3/5.9; and diagnostic confidence, 3.2/6.0. Overall, the RS-EPI had significantly improved diagnostic confidence and more reliably defined the extent and structure of several lesions. Although ASSET EPI scans had better SNR per scanning time, the higher spatial resolution as well as reduced blurring and distortions on RS-EPI scans helped to better reveal important anatomic details at the cortical-subcortical levels, brain stem, temporal and inferior frontal lobes, skull base, sinonasal cavity, cranial nerves, and orbits. CONCLUSIONS: This work shows the importance of both resolution and decreased distortions in the clinics, which can be accomplished by a combination of parallel imaging and alternative k-space trajectories such as RS-EPI.


Assuntos
Encefalopatias/diagnóstico , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/normas , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Adolescente , Artefatos , Astrocitoma/diagnóstico , Neoplasias Encefálicas/diagnóstico , Criança , Pré-Escolar , Empiema Subdural/diagnóstico , Encefalomalacia/diagnóstico , Feminino , Humanos , Lactente , Recém-Nascido , Doença de Leigh/diagnóstico , Masculino , Doença de Moyamoya/diagnóstico , Reprodutibilidade dos Testes
16.
AJNR Am J Neuroradiol ; 32(4): 664-70, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21292797

RESUMO

BACKGROUND AND PURPOSE: MSDE preparation is a technique for black-blood imaging. Our purpose was to evaluate the usefulness of a 3D TSE sequence with MSDE preparation in detecting brain metastases by comparing it with conventional sequences. MATERIALS AND METHODS: Postcontrast images of 227 patients who were suspected of having brain metastasis were prospectively obtained by using 3 T1-weighted 3D sequences: a gradient-echo sequence (MPRAGE), TSE-noMSDE, and TSE-MSDE. The number of visualized blood vessels and the lesion-to-normal CNR were compared among the 3 sequences. An observer test involving 9 radiologists was performed, and their diagnostic performance by using TSE-MSDE, MPRAGE, and combined TSE-MSDE and MPRAGE was compared by means of an FOM as an index of diagnostic performance derived by the JAFROC analysis, sensitivity, FP/case, and reading time. RESULTS: TSE-MSDE resulted in significantly better vessel suppression than the other 2 methods. TSE with and without MSDE resulted in significantly higher CNRs than MPRAGE. In the observer test, significantly higher sensitivity and FOM as well as significantly shorter reading time were achieved by TSE-MSDE compared with MPRAGE, but FP/case was significantly higher with TSE-MSDE. Combined TSE-MSDE/MPRAGE resulted in significantly higher sensitivity and FOM and similar FP/case and reading time compared with MPRAGE alone. CONCLUSIONS: With blood vessel suppression and increased CNR, TSE-MSDE improves radiologists' performances in detecting brain metastases compared with MPRAGE, but it may increase FP results. Combined with MPRAGE, TSE-MSDE achieves high diagnostic performance while maintaining a low FP rate.


Assuntos
Neoplasias Encefálicas/secundário , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Neoplasias Pulmonares/patologia , Neurorradiografia/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Neoplasias da Mama/patologia , Artérias Cerebrais/anatomia & histologia , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Bucais/patologia , Neurorradiografia/estatística & dados numéricos , Variações Dependentes do Observador , Neoplasias Pancreáticas/patologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
AJNR Am J Neuroradiol ; 31(8): 1403-7, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20466799

RESUMO

BACKGROUND AND PURPOSE: Calcium can potentially shorten T1, generating high signal intensity in GREs. Because IPH appears as high signal intensity in MRIPH and the surface effects of calcium can potentially shorten T1 of surrounding water protons, the purpose of this study was to evaluate whether the high signal intensity seen on MRIPH could be attributed solely to IPH and not calcification. MATERIALS AND METHODS: Eleven patients undergoing carotid endarterectomy were imaged by using MRIPH. Calcification was assessed by scanning respective endarterectomy specimens with a tabletop MicroCT. MRIPH/MicroCT correlation used an 8-segment template. Two readers evaluated images from both modalities. Agreement between MRIPH/MicroCT was measured by calculating Cohen κ. RESULTS: High signal intensity was seen in 58.8% and 68.9% (readers 1 and 2, respectively) of MRIPH segments, whereas calcification was seen in 44.7% and 32.1% (readers 1 and 2, respectively) of MicroCT segments. High signal intensity seen by MRIPH showed very good but inverse agreement to calcification (κ = -0.90; P < .0001, 95% CI, -0.93 to -0.86, reader 1; and κ = -0.74; P < .0001; 95% CI, -0.81 to -0.69, reader 2). Most interesting, high signal intensity demonstrated excellent agreement with lack of calcification on MicroCT (κ = 0.92; P < .0001; 95% CI, 0.89-0.94, reader 1; and κ = 0.97; P < .0001; 95% CI, 0.96-0.99, reader 2). In a very small number of segments, high signal intensity was seen in MRIPH, and calcification was seen on MicroCT; however, these represented a very small proportion of segments with high signal intensity (5.9% and 1.6%, readers 1 and 2, respectively). CONCLUSIONS: High signal intensity, therefore, reliably identified IPH, known to describe complicated plaque, rather than calcification, which is increasingly recognized as identifying more stable vascular disease.


Assuntos
Calcinose/patologia , Doenças das Artérias Carótidas/patologia , Hemorragia Cerebral/patologia , Imagem Ecoplanar/métodos , Idoso , Idoso de 80 Anos ou mais , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/patologia , Artérias Carótidas/cirurgia , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/cirurgia , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/cirurgia , Imagem Ecoplanar/normas , Endarterectomia das Carótidas , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Microtomografia por Raio-X
18.
Diagn Interv Radiol ; 15(2): 75-80, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19517375

RESUMO

PURPOSE: We compared periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER, BLADE) MR technique with spin echo (SE) technique for evaluation of artifacts, and detection and delineation of brain lesions. MATERIALS AND METHODS: Contrast-enhanced T1-weighted fluid attenuated inversion recovery (FLAIR) images with BLADE technique (CE T1W-FLAIR BLADE) and contrast-enhanced T1-weighted SE (CE T1W-SE) were performed in 50 patients with intracranial enhancing lesions. These techniques were compared by two neuroradiologists for qualitative analysis of artifacts, lesion detectability, lesion delineation from adjacent structures, and preferred imaging technique; and for quantitative variables, i.e., lesion-to-background and lesion-to-cerebrospinal fluid (CSF) contrast-to-noise (CNR) ratios. Reader agreement was assessed by kappa statistics. RESULTS: All lesions depicted with the CE T1W-SE were also detected with the CE T1W-FLAIR BLADE technique. Delineation of lesions was better on CE T1W-FLAIR BLADE in the majority of patients. Flow-related artifacts were considerably reduced with CE T1W-FLAIR BLADE. A star-like artifact at the level of the 4(th) ventricle was noted on CE T1W-FLAIR BLADE but not on CE T1W-SE. The lesion-to-background CNR and lesion-to-CSF CNR did not show a statistically significant difference between the two techniques. CE T1W-FLAIR BLADE images were preferred by the observers over the CE T1w-SE images, indicating good interobserver agreement (k = 0.70). CONCLUSION: CE T1W-FLAIR BLADE technique is superior to CE T1WSE for delineation of lesions and reduction of flow-related artifacts, especially within the posterior fossa, and is preferred by readers. CE T1W-FLAIR BLADE may be an alternative approach to imaging, especially for posterior fossa lesions.


Assuntos
Encefalopatias/diagnóstico , Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Artefatos , Neoplasias Encefálicas/diagnóstico , Criança , Meios de Contraste/administração & dosagem , Imagem Ecoplanar/instrumentação , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Prospectivos , Sensibilidade e Especificidade , Adulto Jovem
19.
J Clin Endocrinol Metab ; 90(9): 5134-40, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15941871

RESUMO

CONTEXT: We recently showed that pre- and postcontrast spoiled gradient-recalled acquisition in the steady-state (SPGR) was superior to conventional pre- and postcontrast T-1 weighted spin echo (SE) acquisition magnetic resonance imaging (MRI) for the diagnostic evaluation of pituitary tumors in adult patients. OBJECTIVE: The present investigation assessed the use of SPGR vs. SE-MRI in the diagnostic evaluation of ACTH-secreting tumors in children and adolescents with Cushing disease. DESIGN: Data were analyzed retrospectively from a series of patients seen over 7 yr (1997-2004). SETTING: The setting for this study was a tertiary care referral center. PATIENTS: Thirty children with Cushing disease (13 females and 17 males with a mean age of 12 +/- 3 yr) were studied. INTERVENTIONS AND OUTCOME MEASURES: Imaging results were compared with surgical and pathological findings and the clinical outcome. RESULTS: Twenty-eight patients had microadenomas, and two had macroadenomas; the latter were identified by both MRI techniques. Precontrast SE and SPGR-MRI identified four and six of the microadenomas, respectively. Postcontrast SPGR-MRI identified the location of the tumor in 18 of 28 patients, whereas postcontrast SE-MRI identified the location and accurately estimated the size of the tumor in only five patients (P < 0.001). CONCLUSIONS: We conclude that conventional MRI, even with contrast enhancement, mostly failed to identify ACTH-secreting microadenomas in children and adolescents with Cushing disease. Postcontrast SPGR-MRI was superior to SE-MRI and should be used in addition to conventional SE-MRI in the pituitary evaluation of children and adolescents with suspected Cushing disease.


Assuntos
Adenoma/diagnóstico , Adenoma/metabolismo , Hormônio Adrenocorticotrópico/metabolismo , Síndrome de Cushing/diagnóstico , Imageamento por Ressonância Magnética , Neoplasias Hipofisárias/diagnóstico , Neoplasias Hipofisárias/metabolismo , Adenoma/patologia , Adenoma/cirurgia , Adolescente , Criança , Imagem Ecoplanar/normas , Reações Falso-Negativas , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Masculino , Neoplasias Hipofisárias/patologia , Neoplasias Hipofisárias/cirurgia , Estudos Retrospectivos , Sensibilidade e Especificidade
20.
Arthritis Rheum ; 50(3): 811-6, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15022323

RESUMO

OBJECTIVE: Quantitative diagnostic tools for osteoarthritis (OA) are important for evaluating the treatment response to structure-modifying drugs. This study was undertaken to test the technical validity (accuracy) of quantitative magnetic resonance imaging (qMRI) for reliable determination of the total bone interface area, percentage of cartilaginous (denuded) joint surface area, and cartilage thickness in OA. METHODS: High-resolution MRIs of femorotibial and patellar cartilage were acquired in 21 patients prior to total knee arthroplasty, using a T1-weighted gradient-echo sequence with water excitation. After segmentation of original bone interface areas (before disease onset) and the actual cartilage layer, the percentages of cartilaginous joint surface area, cartilage thickness, and cartilage volume were determined using proprietary software. During surgery, the patella and the medial and lateral tibia were resected. Results obtained with qMRI were compared with those obtained by direct image analysis of surface area, cartilage thickness, and cartilage volume of the surgically removed tissue. RESULTS: Pairwise differences between results obtained with qMRI and morphologic analysis were +/-4.6% for percentage of cartilaginous surface area, +/-8.9% for cartilage thickness, and +/-9.1% for cartilage volume. Correlation coefficients ranged from 0.92 (thickness) to 0.98 (volume). CONCLUSION: Quantitative MRI permits technically accurate and differential assessment of increases in eroded joint surface area and reductions in cartilage thickness in OA. The surrogate validity of these parameters requires testing in longitudinal studies. These parameters may be advantageous over determination of cartilage volume alone when diagnosing OA, exploring its progression, or testing responsiveness to new therapies.


Assuntos
Cartilagem Articular/patologia , Imagem Ecoplanar , Articulação do Joelho/patologia , Osteoartrite/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA