J Appl Clin Med Phys ; 25(5): e14360, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38648734

RESUMO

PURPOSE: Breast density is a significant risk factor for breast cancer and can impact the sensitivity of screening mammography. Area-based breast density measurements may not provide an accurate representation of the tissue distribution, therefore volumetric breast density (VBD) measurements are preferred. Dual-energy mammography enables volumetric measurements without additional assumptions about breast shape. In this work we evaluated the performance of a dual-energy decomposition technique for determining VBD by applying it to virtual anthropomorphic phantoms. METHODS: The dual-energy decomposition formalism was used to quantify VBD on simulated dual-energy images of anthropomorphic virtual phantoms with known tissue distributions. We simulated 150 phantoms with volumes ranging from 50 to 709 mL and VBD ranging from 15% to 60%. Using these results, we validated a correction for the presence of skin and assessed the method's intrinsic bias and variability. As a proof of concept, the method was applied to 14 sets of clinical dual-energy images, and the resulting breast densities were compared to magnetic resonance imaging (MRI) measurements. RESULTS: Virtual phantom VBD measurements exhibited a strong correlation (Pearson's r > 0.95 $r > 0.95$ ) with nominal values. The proposed skin correction eliminated the variability due to breast size and reduced the bias in VBD to a constant value of -2%. Disagreement between clinical VBD measurements using MRI and dual-energy mammography was under 10%, and the difference in the distributions was statistically non-significant. VBD measurements in both modalities had a moderate correlation (Spearman's ρ $\rho \ $ = 0.68). CONCLUSIONS: Our results in virtual phantoms indicate that the material decomposition method can produce accurate VBD measurements if the presence of a third material (skin) is considered. The results from our proof of concept showed agreement between MRI and dual-energy mammography VBD. Assessment of VBD using dual-energy images could provide complementary information in dual-energy mammography and tomosynthesis examinations.


Assuntos
Densidade da Mama , Neoplasias da Mama , Mamografia , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Mamografia/métodos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Mama/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Imageamento por Ressonância Magnética/métodos
2.
Eur J Radiol ; 175: 111447, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38677039

RESUMO

OBJECTIVES: Robustness of radiomic features in physiological tissue is an important prerequisite for quantitative analysis of tumor biology and response assessment. In contrast to previous studies which focused on different tumors with mostly short scan-re-scan intervals, this study aimed to evaluate the robustness of radiomic features in cancer-free patients and over a clinically encountered inter-scan interval. MATERIALS AND METHODS: Patients without visible tumor burden who underwent at least two portal-venous phase dual energy CT examinations of the abdomen between May 2016 and January 2020 were included, while macroscopic tumor burden was excluded based upon follow-up imaging for all patients (≥3 months). Further, patients were excluded if no follow-up imaging was available, or if the CT protocol showed deviations between repeated examinations. Circular regions of interest were placed and proofread by two board-certified radiologists (4 years and 5 years experience) within the liver (segments 3 and 6), the psoas muscle (left and right), the pancreatic head, and the spleen to obtain radiomic features from normal-appearing organ parenchyma using PyRadiomics. Radiomic feature robustness was tested using the concordance correlation coefficient with a threshold of 0.75 considered indicative for deeming a feature robust. RESULTS: In total, 160 patients with 480 repeated abdominal CT examinations (range: 2-4 per patient) were retrospectively included in this single-center, IRB-approved study. Considering all organs and feature categories, only 4.58 % (25/546) of all features were robust with the highest rate being found in the first order feature category (20.37 %, 22/108). Other feature categories (grey level co-occurrence matrix, grey level dependence matrix, grey level run length matrix, grey level size zone matrix, and neighborhood gray-tone difference matrix) yielded an overall low percentage of robust features (range: 0.00 %-1.19 %). A subgroup analysis revealed the reconstructed field of view and the X-ray tube current as determinants of feature robustness (significant differences in subgroups for all organs, p < 0.001) as well as the size of the region of interest (no significant difference for the pancreatic head with p = 0.135, significant difference with p < 0.001 for all other organs). CONCLUSION: Radiomic feature robustness obtained from cancer-free subjects with repeated examinations using a consistent protocol and CT scanner was limited, with first order features yielding the highest proportion of robust features.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Tomografia Computadorizada por Raios X/métodos , Pessoa de Meia-Idade , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Idoso , Adulto , Estudos Retrospectivos , Pâncreas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Radiografia Abdominal/métodos , Idoso de 80 Anos ou mais , Baço/diagnóstico por imagem , Tecido Parenquimatoso/diagnóstico por imagem , Músculos Psoas/diagnóstico por imagem , Radiômica
3.
Radiol Med ; 129(5): 677-686, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38512626

RESUMO

PURPOSE: To compare the diagnostic performance of 40 keV and 70 keV virtual monoenergetic images (VMIs) generated from dual-energy CT in the detection of pancreatic cancer. METHODS: This retrospective study included patients who underwent pancreatic protocol dual-energy CT from January 2019 to August 2022. Four radiologists (1-11 years of experience), who were blinded to the final diagnosis, independently and randomly interpreted 40 keV and 70 keV VMIs and graded the presence or absence of pancreatic cancer. For each image set (40 keV and 70 keV VMIs), the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated. The diagnostic performance of each image set was compared using generalized estimating equations. RESULTS: Overall, 137 patients (median age, 71 years; interquartile range, 63-78 years; 77 men) were included. Among them, 62 patients (45%) had pathologically proven pancreatic cancer. The 40 keV VMIs had higher specificity (75% vs. 67%; P < .001), PPV (76% vs. 71%; P < .001), and accuracy (85% vs. 81%; P = .001) than the 70 keV VMIs. On the contrary, 40 keV VMIs had lower sensitivity (96% vs. 98%; P = .02) and NPV (96% vs. 98%; P = .004) than 70 keV VMIs. However, the diagnostic confidence in patients with (P < .001) and without (P = .001) pancreatic cancer was improved in 40 keV VMIs than in 70 keV VMIs. CONCLUSIONS: The 40 keV VMIs showed better diagnostic performance in diagnosing pancreatic cancer than the 70 keV VMIs, along with higher reader confidence.


Assuntos
Neoplasias Pancreáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Pancreáticas/diagnóstico por imagem , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada por Raios X/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Valor Preditivo dos Testes
5.
Radiol Med ; 129(5): 669-676, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38512614

RESUMO

PURPOSE: To investigate the value of photon-counting detector CT (PCD-CT) derived virtual non-contrast (VNC) reconstructions to identify renal cysts in comparison with conventional dual-energy integrating detector (DE EID) CT-derived VNC reconstructions. MATERIAL AND METHODS: We prospectively enrolled consecutive patients with simple renal cysts (Bosniak classification-Version 2019, density ≤ 20 HU and/or enhancement ≤ 20 HU) who underwent multiphase (non-contrast, arterial, portal venous phase) PCD-CT and for whom non-contrast and portal venous phase DE EID-CT was available. Subsequently, VNC reconstructions were calculated for all contrast phases and density as well as contrast enhancement within the cysts were measured and compared. MRI and/or ultrasound served as reference standards for lesion classification. RESULTS: 19 patients (1 cyst per patient; age 69.5 ± 10.7 years; 17 [89.5%] male) were included. Density measurements on PCD-CT non-contrast and VNC reconstructions (arterial and portal venous phase) revealed no significant effect on HU values (p = 0.301). In contrast, a significant difference between non-contrast vs. VNC images was found for DE EID-CT (p = 0.02). For PCD-CT, enhancement for VNC reconstructions was < 20 HU for all evaluated cysts. DE EID-CT measurements revealed an enhancement of > 20 HU in five lesions (26.3%) using the VNC reconstructions, which was not seen with the non-contrast images. CONCLUSION: PCD-CT-derived VNC images allow for reliable and accurate characterization of simple cystic renal lesions similar to non-contrast scans whereas VNC images calculated from DE EID-CT resulted in substantial false characterization. Thus, PCD-CT-derived VNC images may substitute for non-contrast images and reduce radiation dose and follow-up imaging.


Assuntos
Doenças Renais Císticas , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Doenças Renais Císticas/diagnóstico por imagem , Pessoa de Meia-Idade , Fótons , Idoso de 80 Anos ou mais , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos
6.
Clin Radiol ; 79(4): e554-e559, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38453389

RESUMO

AIM: To compare the radiation dose, image quality, and conspicuity of pancreatic ductal adenocarcinoma (PDAC) in pancreatic protocol dual-energy computed tomography (CT) between two X-ray tubes mounted in the same CT machine. MATERIAL AND METHODS: This retrospective study comprised 80 patients (median age, 73 years; 45 men) who underwent pancreatic protocol dual-energy CT from January 2019 to March 2022 using either old (Group A, n=41) or new (Group B, n=39) X-ray tubes mounted in the same CT machine. The imaging parameters were completely matched between the two groups, and CT data were reconstructed at 70 and 40 keV. The CT dose-index volume (CTDIvol); CT attenuation of the abdominal aorta, pancreas, and PDAC; background noise; and qualitative scores for the image noise, overall image quality, and PDAC conspicuity were compared between the two groups. RESULTS: The CTDIvol was lower in Group B than Group A (7.9 versus 9.2 mGy; p<0.001). The CT attenuation of all anatomical structures at 70 and 40 keV was comparable between the two groups (p=0.06-0.78). The background noise was lower in Group B than Group A (12 versus 14 HU at 70 keV, p=0.046; and 26 versus 30 HU at 40 keV, p<0.001). Qualitative scores for image noise and overall image quality at 70 and 40 keV and PDAC conspicuity at 40 keV were higher in Group B than Group A (p<0.001-0.045). CONCLUSION: The latest X-ray tube could reduce the radiation dose and improve image quality in pancreatic protocol dual-energy CT.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Masculino , Humanos , Idoso , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos , Raios X , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Carcinoma Ductal Pancreático/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos
7.
Asian J Surg ; 47(5): 2347-2348, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38331605

RESUMO

BACKGROUND: Gallbladder stones are a common digestive system disease, but their diagnosis can be limited in some cases, especially in identifying "negative" stones, which may be difficult to recognize with traditional CT scans. OBJECTIVE: This study aims to explore the advantages of dual-energy CT in diagnosing negative gallbladder stones through a unique case of gallbladder stones. METHODS AND RESULTS: A case of a 31-year-old female is described, who was diagnosed with gallbladder stones during a physical examination two years ago and occasionally experienced pain in the upper right abdomen. Dual-energy CT scanning revealed a mixed-density stone, approximately 2 cm in diameter, in the neck of the gallbladder, consisting of a calcified shell (positive stone) and a homogenous density nucleus (negative stone). Verified by dual-energy CT, single-energy images and spectral curves can very intuitively identify negative stones, demonstrating significantly superior performance compared to traditional CT. CONCLUSION: Dual-energy CT, through single-energy images and spectral curves, intuitively identifies negative gallbladder stones, showcasing significant advantages compared to traditional CT, and offers a valuable approach to enhancing the diagnostic accuracy of gallbladder stones.


Assuntos
Cálculos Biliares , Tomografia Computadorizada por Raios X , Humanos , Feminino , Adulto , Cálculos Biliares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos
8.
Jpn J Radiol ; 42(5): 468-475, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38311704

RESUMO

PURPOSE: To ascertain the performance of dual-energy CT (DECT) with iodine quantification in differentiating malignant mediastinal and hilar lymph nodes (LNs) from benign ones, focusing on patients with lung adenocarcinoma. MATERIALS AND METHODS: In this study, patients with suspected lung cancer received a preoperative contrast-enhanced DECT scan from Jun 2018 to Dec 2020. Quantitative DECT parameters and the size were compared between metastatic and benign LNs. Their diagnostic performances were analyzed by the ROC curves and compared by using the two-sample t test. RESULTS: 72 patients (23 men, 49 women; mean age 62.5 ± 10.1 years) fulfilled the inclusion criteria. A total of 98 LNs (67 benign, 31 metastatic) were analyzed. The iodine concentration normalized by muscle (NICmuscle) was significantly higher (P < 0.001) in metastatic LNs (4.79 ± 1.70) than in benign ones (3.00 ± 1.45). The optimal threshold of NICmuscle was 3.44, which yielded AUC: 0.798, sensitivity: 83.9%, specificity: 73.1%, accuracy: 76.5%, respectively. Applying the established size parameters with 10 mm as the threshold yielded AUC: 0.600, sensitivity: 29.0%, specificity: 91.0%, accuracy: 71.4%, respectively. The diagnostic performance of NICmuscle was significantly better (P = 0.007) than the performance obtained using the established size parameters. CONCLUSIONS: For lung adenocarcinoma, the quantitative measurement of NICmuscle derived from DECT is useful for differentiating benign and metastatic mediastinal and hilar LNs before surgical intervention.


Assuntos
Adenocarcinoma de Pulmão , Neoplasias Pulmonares , Linfonodos , Metástase Linfática , Estadiamento de Neoplasias , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Tomografia Computadorizada por Raios X/métodos , Adenocarcinoma de Pulmão/diagnóstico por imagem , Adenocarcinoma de Pulmão/patologia , Adenocarcinoma de Pulmão/cirurgia , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Metástase Linfática/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Sensibilidade e Especificidade , Idoso , Meios de Contraste , Estudos Retrospectivos
9.
Eur J Radiol ; 173: 111374, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38422607

RESUMO

PURPOSE OF THE STUDY: The aim of the study was to identify differences in the tumor conspicuity of pancreatic adenocarcinomas in different monoenergetic or polyenergetic reconstructions and contrast phases in photon-counting CT (PCCT). MATERIAL AND METHODS: 34 patients were retrospectively enrolled in this study. Quantitative image analysis was performed with region of interest (ROI) measurements in different monoenergetic levels ranging from 40 up to 70 keV (5-point steps) and polyenergetic series. Tumor-parenchyma attenuation differences and contrast-to-noise-ratio (CNR) were calculated. A qualitative image analysis was accomplished by 4 radiologists using a 5-point Likert scale (1 = "not recognizable" up to 5 = "easy recognizable"). Differences between groups were evaluated for statistical significance using the Friedman test and in case of significant differences pair-wise post-hoc testing with Bonferroni correction was applied. RESULTS: Tumor-parenchyma attenuation difference was significantly different between the different image reconstructions for both arterial- and portal-venous-phase-images (p < 0.001). Tumor-parenchyma attenuation difference was significantly higher on arterial-phase-images at mono40keV compared to polyenergetic images (p < 0.001) and mono55keV images or higher (p < 0.001). For portal-venous-phase-images tumor-parenchyma attenuation difference was significantly higher on mono40keV images compared to polyenergetic images (p < 0.001) and mono50keV images (p = 0.03) or higher (p < 0.001). The same trend was seen for CNR. Tumor conspicuity was rated best on mono40keV images with 4.3 ± 0.9 for arterial-phase-images and 4.3 ± 1.1 for portal-venous-phase-images. In contrast, overall image quality was rated best on polyenergetic-images with 4.8 ± 0.5 for arterial-phase-images and 4.7 ± 0.6 for portal-venous-phase-images. CONCLUSION: Low keV virtual monoenergetic images significantly improve the tumor conspicuity of pancreatic adenocarcinomas in PCCT based on quantitative and qualitative results. On the other hand, readers prefer polyenergetic images for overall image quality.


Assuntos
Adenocarcinoma , Neoplasias Pancreáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Estudos Retrospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Adenocarcinoma/diagnóstico por imagem , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador
10.
Br J Radiol ; 97(1156): 705-715, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38291893

RESUMO

Dual-energy CT (DECT) is an exciting application in CT technology conferring many advantages over conventional single-energy CT at no additional with comparable radiation dose to the patient. Various emerging and increasingly established clinical DECT applications in musculoskeletal (MSK) imaging such as bone marrow oedema detection, metal artefact reduction, monosodium urate analysis, and collagen analysis for ligamentous, meniscal, and disc injuries are made possible through its advanced DECT post-processing capabilities. These provide superior information on tissue composition, artefact reduction and image optimization. Newer DECT applications to evaluate fat fraction for sarcopenia, Rho/Z application for soft tissue calcification differentiation, 3D rendering, and AI integration are being assessed for future use. In this article, we will discuss the established and developing applications of DECT in the setting of MSK radiology as well as the basic principles of DECT which facilitate them.


Assuntos
Doenças da Medula Óssea , Doenças Musculoesqueléticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Doenças Musculoesqueléticas/diagnóstico por imagem , Ácido Úrico
11.
Eur J Radiol ; 171: 111287, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38176085

RESUMO

PURPOSE: To explore the optimal kiloelectron voltage (keV) of virtual monochromatic images (VMIs) of dual-layer spectral detector computed tomography (DLSCT) to display laryngeal and hypopharyngeal squamous cell carcinoma (LHSCC) and its diagnostic performance for preoperative T staging of LHSCC. METHODS: A total of 67 LHSCC patients were included, and the contrast between the tumor and sternocleidomastoid muscle (SM), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image noise of 40-100 keV VMIs and conventional polyenergetic images (CIs) were evaluated. The image quality of the CI and 40-100 keV VMI was evaluated by a five-point method. The VMI with the best image quality was screened out, and the accuracy of the optimal keV VMI and CI for T staging was assessed using clinical T staging as the reference standard. RESULTS: The contrast between the tumor and SM, SNR, CNR and subjective image quality scores of LHSCC on 40-50 keV VMIs were higher than those on CIs (P < 0.05); the image noises of 40-100 keV VMIs were lower than those of CIs (P < 0.05). The 40 keV VMI had the highest SNR, CNR and subjective score of image quality. The accuracy rates of the 40 keV VMI and CI for T staging of LHSCC were 0.86 and 0.63 (P < 0.001), respectively. CONCLUSION: The image quality of 40-50 keV VMI is higher than that of CI, and the diagnostic accuracy of 40 keV VMI is better than that of CI, which is most suitable for preoperative T staging of LHSCC.


Assuntos
Neoplasias de Cabeça e Pescoço , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Carcinoma de Células Escamosas de Cabeça e Pescoço , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Algoritmos , Tomografia Computadorizada por Raios X/métodos , Razão Sinal-Ruído
12.
Acad Radiol ; 31(1): 212-220, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37532596

RESUMO

RATIONALE AND OBJECTIVES: To determine the optimal virtual monoenergetic image (VMI) energy level and the potential of contrast-media (CM) reduction for coronary computed tomography angiography (CCTA) with photon-counting detector CT (PCD-CT). MATERIALS AND METHODS: In this institutional review board-approved study, patients who underwent CCTA with dual-source PCD-CT with an identical scan protocol and radiation dose were included. In group 1, CCTA was performed with our standard CM protocol (volume: 72-85.2 mL, 370 mg iodine/mL). VMIs were reconstructed from 40 to 60 keV at 5 keV increments. Objective image quality (IQ) (vascular attenuation, image noise, and contrast-to-noise ratio [CNR]) was measured. Two blinded, independent readers rated subjective IQ (overall IQ, subjective image contrast, and subjective noise using a five-point discrete visual scale). Results of group 1 served to determine the best VMI level for CCTA. In group 2, CM volume was reduced by 20%, and in group 3 by another 20%. RESULTS: A total of 100 patients were enrolled (45 females, mean age 54 ± 13 years). Inter-reader agreement was good-to-excellent for all comparisons (κ > 0.6). In group 1, the best VMI level regarding objective and subjective IQ was 45 keV, which was selected as the reference for groups 2 and 3. For group 2, mean vascular attenuation was 890 Hounsfield units (HU) and mean CNR was 26, with no differences compared to group 1, 45 keV for both objective and subjective IQ. For group 3, mean vascular attenuation was 676 HU and mean CNR was 21, and all patients were rated as diagnostic except one (severe motion artifacts). CONCLUSION: Increased IQ of PCD-CT can be used for considerable CM volume reduction while still maintaining a diagnostic IQ of CCTA.


Assuntos
Angiografia por Tomografia Computadorizada , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Razão Sinal-Ruído , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos
13.
Eur Radiol ; 34(3): 1816-1824, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37667141

RESUMO

OBJECTIVES: To evaluate the applicability of Bosniak 2019 criteria on a monophasic portal venous phase using rapid kilovoltage-switching DECT (rsDECT). MATERIALS AND METHODS: One hundred twenty-seven renal masses assessed on rsDECT were included, classified according to Bosniak 2019 classification using MRI as the reference standard. Using the portal venous phase, virtual monochromatic images at 40, 50, and 77 keV; virtual unenhanced (VUE) images; and iodine map images were reconstructed. Changes in attenuation values between VUE and 40 keV, 50 keV, and 77 keV measurements were computed and respectively defined as ∆HU40keV, ∆HU50keV, and ∆HU77keV. The values of ∆HU40keV, ∆HU50keV, and ∆HU77keV thresholds providing the optimal diagnostic performance for the detection of internal enhancement were determined using Youden index. RESULTS: Population study included 25 solid renal masses (25/127, 20%) and 102 cystic renal masses (102/127, 80%). To differentiate solid to cystic masses, the specificity of the predefined 20 HU threshold reached 88% (95%CI: 82, 93) using ∆HU77keV and 21% (95%CI: 15, 28) using ∆HU40keV. The estimated optimal threshold of attenuation change was 19 HU on ∆HU77keV, 69 HU on ∆HU50eV, and 111 HU on ∆HU40eV. The rsDECT classification was highly similar to that of MRI for solid renal masses (23/25, 92%) and for Bosniak 1 masses (62/66, 94%). However, 2 hyperattenuating Bosniak 2 renal masses (2/26, 8%) were classified as solid renal masses on rsDECT. CONCLUSION: DECT is a promising tool for Bosniak classification particularly to differentiate solid from Bosniak I-II cyst. However, known enhancement thresholds must be adapted especially to the energy level of virtual monochromatic reconstructions. CLINICAL STATEMENT: DECT is a promising tool for Bosniak classification; however, known enhancement thresholds must be adapted according to the types of reconstructions used and especially to the energy level of virtual monochromatic reconstructions. KEY POINTS: • To differentiate solid to cystic renal masses, predefined 20 HU threshold had a poor specificity using 40 keV virtual monochromatic images. • Most of Bosniak 1 masses according to MRI were also classified as Bosniak 1 on rapid kV-switching dual-energy CT (rsDECT). • Bosniak 2 hyperattenuating renal cysts mimicked solid lesion on rsDECT.


Assuntos
Doenças Renais Císticas , Neoplasias Renais , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Rim/patologia , Imageamento por Ressonância Magnética/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Meios de Contraste
14.
Eur J Radiol ; 170: 111229, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38056348

RESUMO

OBJECTIVE: This research aimed to investigate the feasibility of utilizing dual-energy CT virtual monoenergetic images (VMI1) with prospective electrocardiogram (ECG2) gating for reducing radiation and contrast agent doses in pediatric patients with congenital heart disease (CHD3). METHODS: There were 100 pediatric patients with CHD included in this study. Group A (n = 50) underwent dual-energy scanning with prospective ECG-gating, and group B (n = 50) underwent conventional scanning with retrospective ECG-gating. Comparative analysis of CT values of lumen, objective image quality assessment, subjective image quality evaluations, and diagnostic efficacy were performed. RESULTS: CT values, image noise, signal-to-noise ratio (SNR4), and contrast-to-noise ratio (CNR5) were significantly affected by the VMI energy level, and they all increased with decreasing energy levels (P > 0.05). Combining subjective evaluation, the 45 keV VMI was considered the optimum image in group A. The 45 keV VMI exhibited higher CT values of lumen compared to conventional scanning images (P < 0.003 âˆ¼ 0.836), but meanwhile, the image noise was also higher in the 45 keV VMI (P = 0.004). Differences between the two groups in SNR, CNR, and diagnostic accuracy were not statistically significant. Compared to group B, the 45 keV VMI showed fewer contrast-induced artifacts (P < 0.001) and higher image quality score (P = 0.037). Group A had a 64 % reduction in radiation dose and a 40 % decrease in iodine dose compared to group B. CONCLUSION: The combination of dual-energy CT with prospective ECG-gating reduces radiation and iodine doses in pediatric patients with CHD. The 45 keV VMI can provide clinically acceptable image quality while declining contrast agent artifacts.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Criança , Angiografia por Tomografia Computadorizada , Meios de Contraste , Estudos Retrospectivos , Estudos Prospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Eletrocardiografia
15.
Abdom Radiol (NY) ; 49(1): 103-116, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37796327

RESUMO

PURPOSE: To analyze the conspicuity of pancreatic ductal adenocarcinoma (PDAC) in virtual monoenergetic images (VMI) on a novel photon-counting detector CT (PCD-CT) in comparison to energy-integrating CT (EID-CT). METHODS: Inclusion criteria comprised initial diagnosis of PDAC (reference standard: histopathological analysis) and standardized contrast-enhanced CT imaging either on an EID-CT or a PCD-CT. Patients were excluded due to different histopathological diagnosis or missing tumor delineation on CT. On the PCD-CT, 40-190 keV VMI reconstructions were generated. Image noise, tumor-to-pancreas ratio (TPR) and contrast-to-noise ratio (CNR) were analyzed by ROI-based measurements in arterial and portal venous contrast phase. Two board-certified radiologist evaluated image quality and tumor delineation at both, EID-CT and PCD-CT (40 and 70 keV). RESULTS: Thirty-eight patients (mean age 70.4 years ± 10.3 [range 45-91], 27 males; PCD-CT: n=19, EID-CT: n=19) were retrospectively included. On the PCD-CT, tumor conspicuity (reflected by low TPR and high CNR) was significantly improved at low-energy VMI series (≤ 70 keV compared to > 70 keV), both in arterial and in portal venous contrast phase (P < 0.001), reaching the maximum at 40 keV. Comparison between PCD-CT and EID-CT showed significantly higher CNR on the PCD-CT in portal venous contrast phase at < 70 keV (P < 0.016). On the PCD-CT, tumor conspicuity was improved in portal venous contrast phase compared to arterial contrast phase especially at the lower end of the VMI spectrum (≤ 70 keV). Qualitative analysis revealed that tumor delineation is improved in 40 keV reconstructions compared to 70 keV reconstructions on a PCD-CT. CONCLUSION: PCD-CT VMI reconstructions (≤ 70 keV) showed significantly improved conspicuity of PDAC in quantitative and qualitative analysis in both, arterial and portal venous contrast phase, compared to EID-CT, which may be important for early detection of tumor tissue in clinical routine. Tumor delineation was superior in portal venous contrast phase compared to arterial contrast phase.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Masculino , Humanos , Idoso , Estudos Retrospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Carcinoma Ductal Pancreático/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
16.
Abdom Radiol (NY) ; 49(3): 814-822, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38150141

RESUMO

BACKGROUND: To determine the utility of virtual-monoenergetic imaging (VMI) at low energy levels from contrast-enhanced dual-layer dual-energy (DLDE) computed tomography enterography (CTE) in the preoperative assessment of internal penetrating lesions of Crohn's disease (CD). MATERIALS AND METHODS: Thirty-eight patients with penetrating lesions of CD by surgery undergoing contrast-enhanced DLDE CTE were retrospectively included. Polyenergetic imaging (PEI) and VMIs at low energy levels [40-70 kiloelectron volts (keV)] with 10 keV intervals were reconstructed. The objective parameters of image quality [noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)] and the subjective parameter of image quality [diagnostic performance of lesions (DPL), overall image quality(OIQ)] of PEI and all VMIs at the low energy level were compared to determine the VMI on the optimal energy level. The lesion detection capability between PEI and the optimal VMI was compared. RESULTS: VMI40 was determined to be the optimal VMI among all VMIs at the low energy level for owning the best image quality. No significant difference was found in the detecting capability in penetrating lesions between VMI40 and PEI (p = 1.0), whereas a significant difference was found in the detecting capability in the bowel origin of the penetrating lesions (p = 0.004), the involved organ or structure by the fistula (p = 0.016) and the orifice of the fistula connected to the involved organ or structure ( p = 0.031) between them. CONCLUSIONS: Compared to conventional PEI, VMI40 improves the detection capability in anatomical details of penetrating lesions of CD, helping colorectal surgeons rationalizing preoperative plans of internal penetrating lesions of CD.


Assuntos
Doença de Crohn , Fístula , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/cirurgia , Estudos Retrospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
17.
Eur J Radiol ; 169: 111177, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37944333

RESUMO

PURPOSE: To compare the image quality, contrast administration, and radiation dose between single-energy CT (SECT) and dual-energy CT (DECT) in pediatric patients. METHODS: From March to December 2021, children who underwent abdominal SECT or DECT were retrospectively included in this study. The DECT group received 10-30 % less contrast than the routine dose. CT images were obtained at hepatic venous phase using a routine reconstruction method (iDose4). DECT scans were additionally reconstructed with a virtual monoenergetic image (VMI) at 40 and 65 keV. Quantitative image evaluations compared the contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of the liver, portal vein, and pancreas. Qualitative analysis assessed degree of contrast enhancement, lesion or organ conspicuity, image noise, artificiality, and overall image quality. RESULTS: Among 318 patients, 112 (median age, 16 years; 56 in each group) were included after propensity score matching. Compared with the SECT group, DECT group with iDose4 demonstrated lower CNRs and SNRs, while VMI at 40 or 65 keV showed no significant difference. In qualitative analysis, iDose4 produced higher scores on artificiality, and VMI at 40 keV demonstrated superior contrast enhancement and lesion conspicuity in the DECT group. Overall image quality was higher with VMI 65 keV among the DECT patients, and there was no significant difference compared to SECT. The volume CT dose index (CTDIvol) did not differ significantly between the two groups (median, 2.8 mGy vs. 2.9 mGy; p = 0.802). The injected contrast volume was reduced by 10 % in the DECT group. CONCLUSION: Pediatric abdominal DECT with reduced contrast administration showed no significant differences in image quality and radiation dose compared to SECT.


Assuntos
Meios de Contraste , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Criança , Adolescente , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Pontuação de Propensão , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Doses de Radiação , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
18.
Radiol Clin North Am ; 61(6): 1097-1110, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37758359

RESUMO

Traditional monoenergetic computed tomography (CT) scans in musculoskeletal imaging provide excellent detail of bones but are limited in the evaluation of soft tissues. Dual-energy CT (DECT) overcomes many of the traditional limitations of CT and offers anatomical details previously seen only on MR imaging. In addition, DECT has benefits in the evaluation and characterization of arthropathies, bone marrow edema, and collagen applications in the evaluation of tendons, ligaments, and vertebral discs. There is current ongoing research in the application of DECT in arthrography and bone mineral density calculation.


Assuntos
Doenças da Medula Óssea , Sistema Musculoesquelético , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Sistema Musculoesquelético/diagnóstico por imagem , Coluna Vertebral , Tomografia Computadorizada por Raios X/métodos
19.
Radiol Clin North Am ; 61(6): 987-994, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37758365

RESUMO

This article examines the intrathoracic applications for dual-energy computed tomography (DECT), focusing on lung cancer. The topics covered include the image data sets, methods for iodine quantification, and clinical applications. The applications of DECT are to differentiate benign and malignant lung nodules, determining the grade of lung cancer and expression of ki-67 expression. Iodine quantification has role in assessment of treatment response in both the primary tumor and nodal metastases.


Assuntos
Iodo , Neoplasias Pulmonares , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Neoplasias Pulmonares/diagnóstico por imagem
20.
Eur J Radiol ; 168: 111090, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37742372

RESUMO

Pancreatic diseases are difficult to diagnose due to their insidious onset and complex pathophysiological developmental characteristics. In recent years, dual-energy computed tomography (DECT) imaging technology has rapidly advanced. DECT can quantitatively extract and analyze medical imaging features and establish a correlation between these features and clinical results. This feature enables the adoption of more modern and accurate clinical diagnosis and treatment strategies for patients with pancreatic diseases so as to achieve the goal of non-invasive, low-cost, and personalized treatment. The purpose of this review is to elaborate on the application of DECT for the diagnosis, biological characterization, and prediction of the survival of patients with pancreatic diseases (including pancreatitis, pancreatic cancer, pancreatic cystic tumor, pancreatic neuroendocrine tumor, and pancreatic injury) and to summarize its current limitations and future research prospects.


Assuntos
Pancreatopatias , Neoplasias Pancreáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Tomografia Computadorizada por Raios X/métodos , Pancreatopatias/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos