Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.487
Filtrar
1.
BMC Anesthesiol ; 24(1): 181, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773386

RESUMO

BACKGROUND: Endotracheal intubation is challenging during cardiopulmonary resuscitation, and video laryngoscopy has showed benefits for this procedure. The aim of this study was to compare the effectiveness of various intubation approaches, including the bougie first, preloaded bougie, endotracheal tube (ETT) with stylet, and ETT without stylet, on first-attempt success using video laryngoscopy during chest compression. METHODS: This was a randomized crossover trial conducted in a general tertiary teaching hospital. We included anesthesia residents in postgraduate year one to three who passed the screening test. Each resident performed intubation with video laryngoscopy using the four approaches in a randomized sequence on an adult manikin during continuous chest compression. The primary outcome was the first-attempt success defined as starting ventilation within a one minute. RESULTS: A total of 260 endotracheal intubations conducted by 65 residents were randomized and analyzed with 65 procedures in each group. First-attempt success occurred in 64 (98.5%), 57 (87.7%), 56 (86.2%), and 46 (70.8%) intubations in the bougie-first, preloaded bougie, ETT with stylet, and ETT without stylet approaches, respectively. The bougie-first approach had a significantly higher possibility of first-attempt success than the preloaded bougie approach [risk ratio (RR) 8.00, 95% confidence interval (CI) 1.03 to 62.16, P = 0.047], the ETT with stylet approach (RR 9.00, 95% CI 1.17 to 69.02, P = 0.035), and the ETT without stylet approach (RR 19.00, 95% CI 2.62 to 137.79, P = 0.004) in the generalized estimating equation logistic model accounting for clustering of intubations operated by the same resident. In addition, the bougie first approach did not result in prolonged intubation or increased self-reported difficulty among the study participants. CONCLUSIONS: The bougie first approach with video laryngoscopy had the highest possibility of first-attempt success during chest compression. These results helped inform the intubation approach during CPR. However, further studies in an actual clinical environment are warranted to validate these findings. TRIAL REGISTRATION: Clinicaltrials.gov; identifier: NCT05689125; date: January 18, 2023.


Assuntos
Reanimação Cardiopulmonar , Estudos Cross-Over , Intubação Intratraqueal , Laringoscopia , Manequins , Gravação em Vídeo , Intubação Intratraqueal/métodos , Intubação Intratraqueal/instrumentação , Humanos , Laringoscopia/métodos , Laringoscopia/instrumentação , Reanimação Cardiopulmonar/métodos , Masculino , Feminino , Adulto , Internato e Residência/métodos , Técnicas e Procedimentos Assistidos por Vídeo
2.
Anaesthesiol Intensive Ther ; 56(1): 47-53, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38741443

RESUMO

INTRODUCTION: Laryngeal mask airway-blockbuster (LMA-BT) is a relatively new supraglottic airway device (SGAD). In this study, we compared LMA-BT with I-Gel LMA for efficacy of blind tracheal intubation. MATERIAL AND METHODS: We conducted a single-blind prospective study after ethical approval. One hundred American Society of Anesthesiology (ASA) Grade I-III (age 18-60 years) patients scheduled for elective surgery under general anaesthesia with endotracheal intubation were included and randomly divided into 2 groups. Blind tracheal intubation was performed through LMA-BT ( n = 50) and I-Gel ( n = 50) in groups 1 and 2, respectively. The primary aim was to evaluate the first pass success rate of blind tracheal intubation through the LMAs. The secondary objectives noted were attempts and ease of LMA insertion, total time taken for LMA insertion, airway seal pressure of LMA, ease of NGT insertion through LMA, fibre-optic grading of laryngeal view through LMA, overall success rate and time of intubation through LMA, time for LMA removal, and complications, if any. RESULTS: In the LMA-BT group, the first pass success rate ( P < 0.019) and the overall success rate of intubation ( P < 0.005) were significantly higher than in the I-Gel group. Using LMA-BT also resulted in statistically significant shorter intubation time ( P < 0.0001) with higher airway seal pressure as compared to I-Gel ( P < 0.001). The difference in the first attempt insertion, number of insertion attempts, ease and time of LMA insertion and removal after intubation, and postoperative complications were comparable among the groups. CONCLUSIONS: LMA-BT is a superior device as compared to I-Gel LMA as a conduit for blind tracheal intubation.


Assuntos
Anestesia Geral , Intubação Intratraqueal , Máscaras Laríngeas , Humanos , Intubação Intratraqueal/métodos , Intubação Intratraqueal/instrumentação , Método Simples-Cego , Adulto , Estudos Prospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Anestesia Geral/métodos , Adulto Jovem , Adolescente
3.
Ann Card Anaesth ; 27(1): 65-67, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38722125

RESUMO

ABSTRACT: One-lung ventilation is indicated during thoracic surgery for visualization and exposure of surgical site. It is achieved with bronchial blockers, double-lumen endobronchial tube, single-lumen endotracheal tubes and Univent tube for infants and children. Fibreoptic bronchoscope is required for placing and confirming the correct position of these tubes. We report a perioperative management of safe conduct of one lung ventilation for a 6-year child undergoing left lower lobe lobectomy through C-MAC video laryngoscope guided two single lumen tubes in limited resource settings where paediatric-sized fibreoptic bronchoscope is unavailable.


Assuntos
Intubação Intratraqueal , Ventilação Monopulmonar , Humanos , Ventilação Monopulmonar/métodos , Ventilação Monopulmonar/instrumentação , Intubação Intratraqueal/métodos , Intubação Intratraqueal/instrumentação , Criança , Masculino , Broncoscopia/métodos , Tecnologia de Fibra Óptica , Feminino , Laringoscopia/métodos
4.
BMJ Open ; 14(5): e085503, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38754878

RESUMO

INTRODUCTION: Lung isolation is primarily accomplished using a double-lumen tube (DLT) or bronchial blocker. A precise and accurate size of the DLT is a prerequisite for ensuring its accurate placement. Three-dimensional (3D) reconstruction technology can be used to accurately reproduce tracheobronchial structures to improve the accuracy of DLT size selection. Therefore, we have developed automatic comparison software for 3D reconstruction based on CT data (3DRACS). In this study, we aimed to evaluate the efficiency of using 3DRACS to select the DLT size for endobronchial intubation in comparison with using the 'blind' DLT intubation method to determine the DLT size, which is based on height and sex. METHODS AND ANALYSIS: This is a prospective, single-centre, double-blind randomised controlled trial. In total, 200 patients scheduled for lung resection using a left DLT will be randomly allocated to the 3D group or the control group at a 1:1 ratio. A 3DRACS will be used for the 3D group to determine the size of the DLT, while in the case of the control group, the size of the DLT will be determined according to patient height and sex. The primary outcome is the success rate of placement of the left DLT without fibreoptic bronchoscopy (FOB). The secondary outcomes include the following: successful intubation time, degree of pulmonary atrophy, grade of airway injury, oxygenation during one-lung ventilation, postoperative sore throat and hoarseness, and number of times FOB is used. ETHICS AND DISSEMINATION: Ethical approval has been obtained from our local ethics committee (approval number: SCCHEC-02-2022-155). Written informed consent will be obtained from all participants before randomisation, providing them with clear instructions about the purpose of the study. The results will be disseminated through peer-reviewed publications and conferences. TRIAL REGISTRATION NUMBER: NCT06258954.


Assuntos
Intubação Intratraqueal , Impressão Tridimensional , Humanos , Estudos Prospectivos , Intubação Intratraqueal/métodos , Intubação Intratraqueal/instrumentação , Método Duplo-Cego , Feminino , Masculino , Ensaios Clínicos Controlados Aleatórios como Assunto , Broncoscopia/métodos , Tomografia Computadorizada por Raios X , Adulto , Ventilação Monopulmonar/métodos , Ventilação Monopulmonar/instrumentação , Desenho de Equipamento
6.
Respir Res ; 25(1): 184, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664656

RESUMO

BACKGROUND: In conventional practice, the left double lumen tube (DLT) is rotated 90° counterclockwise when the endobronchial cuff passes glottis. Success rate upon the first attempt is < 80%, likely owing to varying morphology of the bronchial bifurcation. METHODS: We conducted a randomized controlled trial to compare 90° counterclockwise rotation versus individualized degree of rotation in adult patients undergoing elective thoracic surgery using left DLT. The degree of rotation in the individualized group was based on the angle of the left main bronchi as measured on computed tomography (CT). The primary outcome was the first attempt left DLT placement success rate. RESULTS: A total of 556 patients were enrolled: 276 in the control group and 280 in the individualized group. The average angle of the left main bronchi was 100.6±9.5° (range 72° to 119°). The first attempt left DLT placement success rate was 82.6% (228/276) in the control group versus 91.4% (256/280) in the individualized group (P=0.02, χ2 test). The rate of carina mucosal injury, as measured at 30 min after the start of surgery under fibreoptic bronchoscopy, was significantly lower in individualized group than control group (14.0% versus 19.6%, P=0.041). The individualized group also had lower rate of postoperative sore throat (29.4% versus 44.0%, P<0.001) and hoarseness (16.8% versus 24.7%, P<0.05). CONCLUSIONS: Individualized rotation of left DLT based on the angle of the left main bronchi on preoperative CT increased first attempt success rate in adult patients undergoing elective thoracic surgery. TRIAL REGISTRATION: The trial is registered at Chinese Clinical Trial Registry (ChiCTR2100053349; principal investigator Xiang Quan, date of registration November 19, 2021).


Assuntos
Intubação Intratraqueal , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Broncoscopia/métodos , Broncoscopia/instrumentação , Rotação , Adulto , Resultado do Tratamento , Tomografia Computadorizada por Raios X
7.
Vet Anaesth Analg ; 51(3): 266-270, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38565449

RESUMO

OBJECTIVE: To develop and evaluate a low-cost three-dimensional (3D)-printed video laryngoscope (VLVET) for use with a commercial borescope. STUDY DESIGN: Instrument development and pilot study. ANIMALS: A total of six adult male Beagle dogs. METHODS: The VLVET consisted of a laryngoscope handle and a Miller-type blade, and a detachable camera holder that attached to various locations along the blade. The laryngoscope and camera holder were 3D-printed using black polylactic acid filament. Dogs were premedicated with intravenous (IV) medetomidine (15 µg kg-1) and anesthesia induced with IV alfaxalone (1.5 mg kg-1). The VLVET, combined with a borescope, was used for laryngeal visualization and intubation. Performance was evaluated by comparing direct and video-assisted views in sternal recumbency. The borescope camera was sequentially positioned at 2, 4, 6, 8 and 10 cm from the blade tip (distanceLARYNX-CAM), which was placed on the epiglottis during intubation or laryngoscopy. At the 10 cm distanceLARYNX-CAM, laryngeal visualization was sequentially scored at inter-incisor gaps of 10, 8, 6, 4 and 2 cm. Laryngeal visualization scores (0-3 range, with 0 = obstructed and 3 = unobstructed views) were statistically analyzed using the Friedman's test. RESULTS: Under direct visualization, the 2 cm distanceLARYNX-CAM had a significantly lower score compared with all other distanceLARYNX-CAM (all p = 0.014) because the view was obstructed by the camera holder and borescope camera. With both direct and camera-assisted views, visualization scores were higher at inter-incisor gaps ≥ 4 cm compared with 2 cm (all p < 0.05). CONCLUSIONS AND CLINICAL RELEVANCE: During laryngoscopy and intubation, the VLVET and borescope facilitated both direct and video laryngoscopy at distanceLARYNX-CAM in Beagle dogs when inter-incisor gaps were ≥ 4 cm.


Assuntos
Intubação Intratraqueal , Laringoscópios , Impressão Tridimensional , Animais , Cães , Laringoscópios/veterinária , Masculino , Intubação Intratraqueal/veterinária , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Gravação em Vídeo , Laringoscopia/veterinária , Laringoscopia/métodos , Laringoscopia/instrumentação , Projetos Piloto , Desenho de Equipamento
8.
Transfusion ; 64 Suppl 2: S201-S209, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38545924

RESUMO

INTRODUCTION: Video laryngoscope (VL) technology improves first-pass success. The novel i-view VL device is inexpensive and disposable. We sought to determine the first-pass intubation success with the i-view VL device versus the standard reusable VL systems in routine use at each site. METHODS: We performed a prospective, pragmatic study at two major emergency departments (EDs) when VL was used. We rotated i-view versus reusable VL as the preferred device of the month based on an a priori schedule. An investigator-initiated interim analysis was performed. Our primary outcome was a first-pass success with a non-inferiority margin of 10% based on the per-protocol analysis. RESULTS: There were 93 intubations using the reusable VL devices and 81 intubations using the i-view. Our study was stopped early due to futility in reaching our predetermined non-inferiority margin. Operator and patient characteristics were similar between the two groups. The first-pass success rate for the i-view group was 69.1% compared to 84.3% for the reusable VL group. A non-inferiority analysis indicated that the difference (-15.1%) and corresponding 90% confidence limits (-25.3% to -5.0%) did not fall within the predetermined 10% non-inferiority margin. CONCLUSIONS: The i-view device failed to meet our predetermined non-inferiority margin when compared to the reusable VL systems with the study stopping early due to futility. Significant crossover occurred at the discretion of the intubating operator during the i-view month.


Assuntos
Intubação Intratraqueal , Laringoscópios , Humanos , Estudos Prospectivos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Serviço Hospitalar de Emergência , Reutilização de Equipamento , Laringoscopia/métodos , Laringoscopia/instrumentação
9.
Ann Otol Rhinol Laryngol ; 133(6): 581-589, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38491861

RESUMO

OBJECTIVE: Compare ventilation pressures of 2 endotracheal tube designs used in laser airway surgery in clinical practice and with a benchtop model to elucidate differences and understand the design elements that impact airflow dynamics. METHODS: Ventilatory and aerodynamic characteristics of the laser resistant stainless-steel endotracheal tube (LRSS-ET) design and the laser resistant aluminum-wrapped silicone endotracheal tube (LRAS-ET) design were compared. Ventilatory parameters were collected for 32 patients undergoing laser-assisted airway surgery through retrospective chart review. An in vitro benchtop simulation measured average resistance and centerline turbulence intensity of both designs at various diameters and physiological frequencies. RESULTS: Baseline patient characteristics did not differ between the 2 groups. Clinically, the median LRAS-ET peak inspiratory pressure (PIP; 21.00 cm H2O) was significantly decreased compared to LRSS-ET PIP (34.67 cm H2O). In benchtop simulation, the average PIP of the LRAS-ET was significantly lower at all sizes and frequencies. The LRSS-ET consistently demonstrated an increased resistance, although no patterns were observed in turbulence intensity data between both designs. CONCLUSION: The benchtop model demonstrated increased resistance in the LRSS-ET compared to the LRAS-ET at all comparable sizes. This finding is supported by retrospective ventilatory pressures during laser airway surgery, which show significantly increased PIPs when comparing identically sized inner diameters. Given the equivocal turbulence intensity data, these differences in resistance and pressures are likely caused by wall roughness and intraluminal presence of tubing, not inlet or outlet geometries. The decreased PIPs of the LRAS-ET should assist in following lung protective ventilator management strategies and reduce risk of pulmonary injury and hemodynamic instability to the patient.


Assuntos
Desenho de Equipamento , Intubação Intratraqueal , Humanos , Intubação Intratraqueal/instrumentação , Feminino , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Terapia a Laser/métodos , Idoso , Adulto , Resistência das Vias Respiratórias/fisiologia , Lasers
11.
Laryngoscope ; 134 Suppl 7: S1-S12, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38224197

RESUMO

OBJECTIVES: Surgical fires, particularly within Otolaryngology, remain a surprisingly frequent and devastating complication of laser-related surgery in the oropharynx and airway; Current estimates suggest anywhere from 200 to 600 surgical fires per year in the United States, with 20%-30% of these occurring as a complication of laser surgery and 90%-95% of these occurring in the head and neck region. Unfortunately, the complications of laser surgery in the airway may include respiratory failure, airway burns with stenosis, and may result in mortality. The most commonly utilized endotracheal tube for protection against inadvertent laser strikes, the Laser-Shield II tube (Medtronic), was removed from the commercial marketplace in 2016 after cases of airway fires were reported as a result of feature deficiencies in the product (FDA MAUDE Database review). Since the demise of the Laser-Shield II tube, alternatives such as the Mallinckrodt laser tube and handmade reinforced tubes have been utilized, although shortcomings in design and features have made these options less appealing to practicing Otolaryngologists. Creating a laser-safe endotracheal tube is critical for safe upper airway surgery. This paper evaluates new technologies, materials, and technical innovations in endotracheal tubes that may advance patient safety in laser-assisted Otolaryngology procedures. STUDY TYPE: This paper evaluates new technologies, materials, and technical innovations in endotracheal tubes that may advance patient safety in laser-assisted Otolaryngology procedures. METHODS: First, this article reviews the background of laser surgery in Otolaryngology and the consequent risk of surgical fire with resultant development of laser-resistant endotracheal tubes and commercial availability. Next, a review of claims and national database review of product failures related to previous laser-resistant endotracheal tubes is performed through the FDA MAUDE database. This includes an evaluation of cases: review of techniques in laser airway surgery including spontaneous ventilation, decreased O2 concentration, currently available endotracheal tubes including "handmade" fixes for perceived safety risks, and determination of failure points for previous laser-resistant endotracheal tubes. Third, the paper reviews the requested features of an "ideal" laser-resistant endotracheal tube. Finally, the paper reviews failure testing from an initial, unsuccessful attempt at material development and the consequent development of alternative technologies that address failure points from previous endotracheal tubes and addresses requested features with a detailed analysis of FDA-approval required testing. Extensive lab testing of the new tube predicts a significant reduction of risk in vivo with inability to perforate the shaft or cuff of the tubes under standard working conditions. RESULTS: While no iteration of a laser-resistant endotracheal tube is entirely laser safe, advances in technology can improve the safety profile of these devices. The new tube contains a double cuff, a soft and flexible shaft to minimize laryngeal insertion trauma, a smooth external surface, a tight-to-shaft balloon, and methylene blue dye in the cuff to alert the user to inadvertent penetration. These characteristics were the most requested by laryngologists in the development of a new laser-resistant tube. The newest endotracheal tube brings the features most requested by Otolaryngologists in a laser-resistant tube, and improves the safety profile over previous tubes. CONCLUSION: Development of a new endotracheal tube represents an advancement in safety for the Otolaryngologist in laser airway surgery. Understanding the previous history and the science behind surgical fire formation is essential in advancing safety for patients in the future. LEVEL OF EVIDENCE: N/A Laryngoscope, 134:S1-S12, 2024.


Assuntos
Desenho de Equipamento , Intubação Intratraqueal , Terapia a Laser , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/métodos , Humanos , Terapia a Laser/métodos , Terapia a Laser/instrumentação , Terapia a Laser/efeitos adversos , Incêndios/prevenção & controle
13.
Emerg Med Australas ; 36(3): 476-478, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38290834

RESUMO

OBJECTIVE: To describe initial experience with use of the Glidescope Go videolaryngoscope by an Australian neonatal pre-hospital and retrieval service. METHODS: We conducted a 31-month retrospective review of an airway registry for neonates intubated by MedSTAR Kids clinicians. RESULTS: Twenty-two patients were intubated using the Glidescope Go, compared with 50 using direct laryngoscopy. First-pass success was 17/22 (77.3%) with the Glidescope Go and 38/50 (76%) with direct laryngoscopy. Complications occurred in 7/22 (32%) and 8/50 (16%), respectively. CONCLUSIONS: On initial review of this practice change, videolaryngoscopy allows neonatal tracheal intubation with a comparable success rate to direct laryngoscopy in a pre-hospital and retrieval setting.


Assuntos
Intubação Intratraqueal , Laringoscopia , Gravação em Vídeo , Humanos , Estudos Retrospectivos , Recém-Nascido , Laringoscopia/métodos , Laringoscopia/instrumentação , Intubação Intratraqueal/métodos , Intubação Intratraqueal/instrumentação , Masculino , Feminino , Gravação em Vídeo/métodos , Serviços Médicos de Emergência/métodos , Laringoscópios , Austrália
14.
Anaesthesia ; 79(6): 603-610, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38114306

RESUMO

Hyperangulated videolaryngoscopes are known to increase the success rate of tracheal intubation in the setting of difficult airway management when used with a stylet or bougie. However, there is controversy over which adjunct is more useful. This randomised study aimed to compare first attempt tracheal intubation success rate between a stylet and bougie when using a hyperangulated videolaryngoscope. We recruited patients aged > 20 years who were scheduled for elective surgery under general anaesthesia and required tracheal intubation. We only included patients with factors predicting difficult tracheal intubation based on pre-anaesthesia airway evaluation. Tracheal intubation was attempted using a Glidescope® with either a stylet or bougie as an adjunct according to group assignment. Primary outcome was the success rate of the first tracheal intubation attempt, and secondary outcomes were success of second and third attempts; tracheal intubation time; and occurrence of sore throat, dysphagia or hoarseness. A total of 166 patients were included. The success rate of the first tracheal intubation attempt was significantly higher in patients allocated to the bougie group compared with those allocated to the stylet group (81/83 (98%) vs. 73/83 (88%), respectively; p = 0.032). The number of patients who needed two attempts was significantly lower in those allocated to the bougie group compared with those allocated to the stylet group (1/83 (1%) vs. 9/83 (11%), respectively; p = 0.018). Each group had one patient (1%) where tracheal intubation was achieved after a third attempt. There was no significant difference in the occurrence of sore throat, dysphagia and hoarseness between the two groups. When difficult tracheal intubation is anticipated and a hyperangulated videolaryngoscope is used, the success rate of the first attempt is higher when a bougie is used compared with a stylet.


Assuntos
Intubação Intratraqueal , Laringoscópios , Laringoscopia , Humanos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Laringoscopia/métodos , Laringoscopia/instrumentação , Gravação em Vídeo , Adulto , Faringite/etiologia , Faringite/epidemiologia , Desenho de Equipamento , Anestesia Geral/métodos , Resultado do Tratamento , Rouquidão/etiologia
15.
J Anesth ; 37(4): 582-588, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37311898

RESUMO

BACKGROUND: Videolaryngoscopes may not be as effective in small children as they are in older children and in adults. The size 1 blade is commercially available for the McGRATH®MAC videolaryngoscope (Covidien, Medtronic, Tokyo, Japan), but its efficacy in comparison with a Macintosh laryngoscope blade 1 is not known. AIM: The main aim of this study was to assess the efficacy of McGrath®MAC blade 1 in comparison with a conventional Macintosh laryngoscope blade 1, in children aged less than 24 months. METHODS: Thirty-eight children aged less than 24 months were randomly allocated to one of two groups, and tracheal intubation was attempted using either a direct laryngoscope with a Macintosh blade 1 or a videolaryngoscope with a McGRATH®MAC blade 1. In another 12 children aged 2-4 years, the same comparisons were made with blade 2. The primary outcome measure was time to tracheal intubation using a size 1 blade. RESULTS: Tracheal intubation took significantly longer with a McGRATH®MAC blade 1 (median (interquartile range): 38.0 (31.8-43.5) s) than with the Macintosh blade 1(27.4 (25.9-29.2) s) (p < 0.0001; median difference (95% CI for the median difference): 10.6 (6.4-14.0) s), mainly due to difficulty in advancing a tube into the trachea. No significant difference was observed for the size 2. CONCLUSIONS: In small children without predicted difficult airways, time to intubate the trachea was significantly longer for a McGRATH®MAC blade 1 than a Macintosh blade 1. CLINICAL TRIAL REGISTRATION: jRCT1032220366.


Assuntos
Intubação Intratraqueal , Laringoscópios , Cirurgia Vídeoassistida , Adulto , Criança , Humanos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Japão , Laringoscopia , Traqueia , Cirurgia Vídeoassistida/métodos
16.
Acta Clin Croat ; 62(Suppl1): 149-153, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38746612

RESUMO

Difficult airway management poses a great challenge for clinicians, especially if it is unanticipated. Numerous guidelines and a wide array of devices constitute the anesthesiologist's armamentarium for managing the airway. When the use of individual devices fails, the use of combination techniques is advised. We present a case of difficult intubation in a 50-year-old male patient scheduled for aortic valve replacement. He had no prior history of difficult airway management, and no abnormalities were detected on preoperative airway assessment. Body mass index was 29 kg/m2. After the separate use of direct laryngoscopy, videolaryngoscopy and a BONFILS intubation endoscope (BIE) had failed, we resorted to a combination technique, combining videolaryngoscopy and BIE. While the videolaryngoscope provided the space needed for BIE and visual guidance through copious secretions, the BIE served as a stylet for endotracheal tube guidance, leading to successful intubation. Since the technique requires costly equipment, experience in handling it and at least two operators, it is more appropriate as a rescue measure than an elective procedure. Given the potentially disastrous outcomes of failed intubation, mastering advanced airway management techniques remains of vital importance, and the combination technique is one of them.


Assuntos
Intubação Intratraqueal , Laringoscópios , Laringoscopia , Humanos , Masculino , Pessoa de Meia-Idade , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Laringoscopia/métodos , Laringoscopia/instrumentação , Manuseio das Vias Aéreas/métodos , Manuseio das Vias Aéreas/instrumentação , Técnicas e Procedimentos Assistidos por Vídeo
17.
Br J Anaesth ; 129(4): 635-642, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35999074

RESUMO

BACKGROUND: The appropriate size of GlideScope® blade for tracheal intubation in neonates and premature infants has not been established. We evaluated the impact of the size of the GlideScope® blade on the time taken for intubation in infants weighing 2.5-3.6 kg. METHODS: Sixty infants weighing 2.5-3.6 kg were randomly assigned to use of the size 1 blade (n=30) or the size 2 blade (n=30). The primary outcome was the time taken to intubate. Components related to the laryngoscopic view which could affect the duration of the intubating process were also analysed. RESULTS: The time required for tracheal intubation was shorter with the size 2 blade than with the size 1 blade (16 [14-20] s vs 22 [18-25] s, P=0.002; median difference=-5; 95% confidence interval, -7 to -2). The rate at which the tip of the tracheal tube was located at the centre of the laryngeal inlet was higher with the size 2 blade than with the size 1 blade (83% vs 40%, P<0.001). Correlation analysis indicated that the time required to find the tip of the tube was related to how far the lower border of the arytenoid cartilages was located from the mid-horizontal line of the monitor (r=0.28, P=0.033). CONCLUSION: Use of the size 2 blade significantly reduced the time required to intubate the trachea, compared with the size 1 GlideScope® blade in infants. CLINICAL TRIAL REGISTRATION: KCT 0003867.


Assuntos
Intubação Intratraqueal , Laringoscópios , Desenho de Equipamento , Humanos , Recém-Nascido , Intubação Intratraqueal/instrumentação , Laringoscopia , Respiração Artificial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA