Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
1.
PLoS Med ; 19(3): e1003930, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35235573

RESUMO

BACKGROUND: Low syphilis testing uptake is a major public health issue among men who have sex with men (MSM) in many low- and middle-income countries. Syphilis self-testing (SST) may complement and extend facility-based testing. We aimed to evaluate the effectiveness and costs of providing SST on increasing syphilis testing uptake among MSM in China. METHODS AND FINDINGS: An open-label, parallel 3-arm randomized controlled trial (RCT) was conducted between January 7, 2020 and July 17, 2020. Men who were at least 18 years of age, had condomless anal sex with men in the past year, reported not testing for syphilis in the last 6 months, and had a stable residence with mailing addresses were recruited from 124 cities in 26 Chinese provinces. Using block randomization with blocks of size 12, enrolled participants were randomly assigned (1:1:1) into 3 arms: standard of care arm, standard SST arm, and lottery incentivized SST arm (1 in 10 chance to win US$15 if they had a syphilis test). The primary outcome was the proportion of participants who tested for syphilis during the trial period and confirmed with photo verification and between arm comparisons were estimated with risk differences (RDs). Analyses were performed on a modified intention-to-treat basis: Participants were included in the complete case analysis if they had initiated at least 1 follow-up survey. The Syphilis/HIV Duo rapid test kit was used. A total of 451 men were enrolled. In total, 136 (90·7%, 136/150) in the standard of care arm, 142 (94·0%, 142/151) in the standard of SST arm, and 137 (91·3%, 137/150) in the lottery incentivized SST arm were included in the final analysis. The proportion of men who had at least 1 syphilis test during the trial period was 63.4% (95% confidence interval [CI]: 55.5% to 71.3%, p = 0.001) in the standard SST arm, 65.7% (95% CI: 57.7% to 73.6%, p = 0.0002) in the lottery incentivized SST arm, and 14.7% (95% CI: 8.8% to 20.7%, p < 0.001) in the standard of care arm. The estimated RD between the standard SST and standard of care arm was 48.7% (95% CI: 37.8% to 58.4%, p < 0.001). The majority (78.5%, 95% CI: 72.7% to 84.4%, p < 0.001) of syphilis self-testers reported never testing for syphilis. The cost per person tested was US$26.55 for standard SST, US$28.09 for the lottery incentivized SST, and US$66.19 for the standard of care. No study-related adverse events were reported during the study duration. Limitation was that the impact of the Coronavirus Disease 2019 (COVID-19) restrictions may have accentuated demand for decentralized testing. CONCLUSIONS: Compared to standard of care, providing SST significantly increased the proportion of MSM testing for syphilis in China and was cheaper (per person tested). TRIAL REGISTRATION: Chinese Clinical Trial Registry: ChiCTR1900022409.


Assuntos
Infecções por HIV/diagnóstico , Homossexualidade Masculina , Participação do Paciente/métodos , Autoteste , Sífilis/diagnóstico , Adolescente , Adulto , COVID-19/epidemiologia , China/epidemiologia , Seguimentos , Infecções por HIV/prevenção & controle , Acessibilidade aos Serviços de Saúde/organização & administração , Homossexualidade Masculina/estatística & dados numéricos , Humanos , Imunoensaio/métodos , Masculino , Programas de Rastreamento/economia , Programas de Rastreamento/métodos , Programas de Rastreamento/organização & administração , Pessoa de Meia-Idade , Motivação , Pandemias , Kit de Reagentes para Diagnóstico/economia , Kit de Reagentes para Diagnóstico/provisão & distribuição , SARS-CoV-2 , Minorias Sexuais e de Gênero/estatística & dados numéricos , Sífilis/epidemiologia , Sífilis/prevenção & controle , Adulto Jovem
2.
Ann Surg ; 274(3): 481-490, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34183517

RESUMO

INTRODUCTION: Identification of residual disease after neuroendocrine tumor (NET) resection is critical for management. Post-surgery imaging is insensitive, expensive, and current biomarkers ineffective. We evaluated whether the NETest, a multigene liquid biopsy blood biomarker, correlated with surgical resection and could predict recurrence. METHODS: Multicenter evaluation of NET resections over 24 months (n = 103): 47 pancreas, 26 small bowel, 26 lung, 2 appendix, 1 duodenum, 1 stomach. Surgery: R0 (83), R1/R2 (20). One millilitre of blood was collected at D0 and posroperative day (POD) 30. Transcript quantification by polymerase chain reaction (normal: ≤20), CgA by NEOLISA (normal ≤108 ng/mL). Standard-of-care (SoC) follow-up costs were calculated and compared to POD30 NETest-stratification approach. Analyses: Wilcoxon-paired test, Chi-square test. D BIOMARKERS: NETest: 103 of 103 (100%)-positive, whereas 23 of 103 (22%) were CgA-positive (Chi-square = 78, P < 0.0001).In the R0 group, the NETest decreased 59 ± 28 to 26 ± 23 (P < 0.0001); 36% (30/83) remained elevated. No significant decrease was evident for CgA. In the R1/R2 group the NETest decreased but 100% remained elevated. CgA levels did not decrease.An elevated POD30 NETest was present in R0 and 25 (83%) developed radiological recurrences. Normal score R0 s (n = 53) did not develop recurrence (Chi-square = 56, P < 0.0001). Recurrence prediction was 94% accurate with the NETest. COST EVALUATION: Using the NETest to stratify postoperative imaging resulted in a cost-savings of 42%. CONCLUSION: NETest diagnosis is more accurate than CgA (100% vs 22%). Surgery significantly decreased NETest. An elevated POD30 NETest predicted recurrence with 94% accuracy and post-surgical POD30 NETest follow-up stratification decreased costs by 42%. CgA had no surgical utility. Further studies would define the accuracy and cost-effectiveness of the NETest in the detection of postoperative recurrent disease.


Assuntos
Biomarcadores Tumorais/sangue , Biópsia Líquida/instrumentação , Recidiva Local de Neoplasia/diagnóstico , Tumores Neuroendócrinos/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/genética , Análise Custo-Benefício , Progressão da Doença , Feminino , Genômica/economia , Genômica/métodos , Humanos , Biópsia Líquida/economia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/genética , Neoplasia Residual/diagnóstico , Neoplasia Residual/genética , Tumores Neuroendócrinos/genética , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , RNA Mensageiro/sangue , Kit de Reagentes para Diagnóstico/economia , Sensibilidade e Especificidade
3.
Future Oncol ; 16(36): 3061-3074, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32902306

RESUMO

Background: Prior studies have established that broader incorporation of active surveillance, guided by additional prognostic tools, may mitigate the growing economic burden of localized prostate cancer in the USA. This study sought to further explore the potential of a particular gene expression-based prognostic tool to address this unmet need. Materials & methods: A deterministic, decision-analytic model was developed to estimate the economic impact of the Prolaris® test on a US commercial health plan. Results & conclusion: When adopted in patients classified by the American Urological Association as low or intermediate risk, the assay was projected to reduce costs by $1894 and $2129 per patient over 3 and 10 years, respectively, largely through the increased use of active surveillance.


Assuntos
Biomarcadores Tumorais/genética , Redução de Custos , Perfilação da Expressão Gênica/economia , Neoplasias da Próstata/diagnóstico , Conduta Expectante/economia , Assistência ao Convalescente/economia , Antagonistas de Androgênios/economia , Antagonistas de Androgênios/uso terapêutico , Biomarcadores Tumorais/análise , Biópsia , Ciclo Celular/genética , Quimiorradioterapia/economia , Quimiorradioterapia/métodos , Simulação por Computador , Análise Custo-Benefício/métodos , Análise Custo-Benefício/estatística & dados numéricos , Perfilação da Expressão Gênica/instrumentação , Regulação Neoplásica da Expressão Gênica , Humanos , Masculino , Modelos Econômicos , Prognóstico , Próstata/patologia , Próstata/cirurgia , Prostatectomia/economia , Neoplasias da Próstata/economia , Neoplasias da Próstata/genética , Neoplasias da Próstata/terapia , Radioterapia Adjuvante/economia , Kit de Reagentes para Diagnóstico/economia , Medição de Risco/economia , Medição de Risco/métodos , Estados Unidos , Conduta Expectante/métodos
4.
Afr J Prim Health Care Fam Med ; 12(1): e1-e3, 2020 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-32787398

RESUMO

The use of SARS-CoV-2 rapid diagnostic test (RDT) kits by some African countries for screening has raised serious concerns over their role in malaria areas. Coupled with a lack of adequate personal protective equipment and the scarcity of knowledge on the possible interaction between malaria and COVID-19 both in terms of presentations and shared symptoms, this has left many frontline health workers with fears and anxieties. Several anecdotal reports have already raised questions pertaining to possible false-positive COVID-19 results in proven malaria cases by use of SARS-CoV-2 RDT kits with huge costs to already constrained budgets. The report raises concerns on the use of SARS-CoV-2 kits in malaria areas in terms of cost, to prompt research, allay fears and guide policy during this pandemic and beyond.


Assuntos
Infecções por Coronavirus/diagnóstico , Malária/diagnóstico , Pneumonia Viral/diagnóstico , África/epidemiologia , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico , Infecções por Coronavirus/epidemiologia , Diagnóstico Diferencial , Reações Falso-Positivas , Humanos , Malária/epidemiologia , Programas de Rastreamento , Pandemias , Pneumonia Viral/epidemiologia , Kit de Reagentes para Diagnóstico/economia
6.
PLoS One ; 14(9): e0221495, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31509545

RESUMO

Cytology remains the mainstay of cervical cancer screening in South Africa (SA), however false negative rates are 25-50%. In contrast, human papillomavirus (HPV) screening techniques have higher sensitivity for cervical cancer precursors. The cobas® 4800 HPV test detects pooled high-risk HPV types and individual genotypes HPV 16 and 18. Using a mathematical budget impact model, the study objective was to evaluate the clinical and budget impact of replacing primary liquid-based cytology (LBC) with primary HPV-based screening strategies. In SA, current LBC screening practice recommends one test every ten years, followed by large loop excision of the transformation zone (LLETZ) if indicated. HPV testing can be performed from an LBC sample, where no additional consultations nor samples are required. In the budget impact model, LBC screening for 2 cycles (one test every ten years) was compared to cobas® 4800 HPV test for 2 cycles (one test every 5 years). The model inputs were gathered from literature and primary data sources. Indicative prices for LBC and cobas® 4800 HPV test were R189 and R457, respectively. Model results indicate that best outcomes for detection of disease were seen using cobas® 4800 HPV test. Forty-eight percent of cervical cancer cases were detected compared to 28% using LBC, and 50% of cervical intraepithelial neoplasia (CIN) 2 and CIN3 cases, compared to 25% with LBC. The budget impact analysis predicted that the cost per detected case of CIN2 or higher would be R 56,835 and R46,980 for the cobas® 4800 HPV and LBC scenarios, respectively. This equates to an incremental cost per detected case of CIN2 or higher of R9 855. From this model we conclude that a primary HPV screening strategy will have a significant clinical impact on disease burden in South Africa.


Assuntos
Detecção Precoce de Câncer/economia , Papillomavirus Humano 16/isolamento & purificação , Papillomavirus Humano 18/isolamento & purificação , Infecções por Papillomavirus/diagnóstico , Displasia do Colo do Útero/virologia , Neoplasias do Colo do Útero/virologia , Análise Custo-Benefício , Citodiagnóstico/economia , DNA Viral , Feminino , Papillomavirus Humano 16/genética , Papillomavirus Humano 18/genética , Humanos , Modelos Econômicos , Infecções por Papillomavirus/economia , Prevalência , Setor Público , Kit de Reagentes para Diagnóstico/economia , Sensibilidade e Especificidade , África do Sul/epidemiologia , Neoplasias do Colo do Útero/economia , Displasia do Colo do Útero/economia
7.
S Afr Med J ; 109(4): 227-231, 2019 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-31084686

RESUMO

Current research suggests that HIV self-screening (HIVSS) is a feasible and acceptable approach to increase HIV testing among men who have sex with men (MSM). However, few data are available to shape policy around dissemination and implementation. Gaps in knowledge include preferences for distribution of HIVSS kits, potential social harms and benefits of their use, and how much test users would be willing to pay for the kits. The aim was to inform policy recommendations to optimise distribution of HIVSS kits to MSM in South Africa (SA), where there is a high HIV incidence and unmet testing needs. MSM in the high-HIV-prevalence Gert Sibande and Ehlanzeni districts of Mpumalanga Province, SA, were enrolled between October 2015 and May 2017. Participants were provided with their choice of blood or oral fluid HIVSS test kits, receiving 5 kits at enrolment and 4 additional kits at the 3-month follow-up visit. Questionnaires were administered at enrolment, 3 months and 6 months. We analysed participants' reported social benefits and harms, and their preferences for kit distribution and pricing. Among 127 MSM screened and enrolled, 114 responded to follow-up questionnaires regarding distribution preferences, 49.3% preferred to acquire HIVSS kits at a community-based organisation (CBO) and 42.7% at a clinic, with 8% preferring a pharmacy. Participants with higher education preferred CBO sites for distribution; in other respects preferences were similar by demographic characteristics. Reported social benefits were common, including knowing one's status, prevention knowledge gained and improved communication with partners. Despite ubiquitous interest in using the kits, the majority of MSM could not afford to purchase test kits. SA guidelines have integrated HIVSS into HIV and testing policy, but little has been published regarding distribution channels of the kits for MSM and other key populations. There is a partnership between the National Department of Health and CBOs that specialise in key population programming to ensure MSM and other populations with unmet testing needs can access affordable test kits. We observed no social harms, and there were multiple social benefits. Consequently, we recommend immediate free or low-cost distribution of HIVSS kits to MSM through community-based initiatives. Future research should continue to assess optimised linkage to care.


Assuntos
Autoavaliação Diagnóstica , Infecções por HIV/diagnóstico , Política de Saúde , Homossexualidade Masculina , Programas de Rastreamento , Preferência do Paciente/psicologia , Kit de Reagentes para Diagnóstico , Adolescente , Adulto , Seguimentos , Infecções por HIV/economia , Infecções por HIV/prevenção & controle , Infecções por HIV/psicologia , Acessibilidade aos Serviços de Saúde/economia , Inquéritos Epidemiológicos , Humanos , Masculino , Programas de Rastreamento/instrumentação , Programas de Rastreamento/métodos , Programas de Rastreamento/organização & administração , Preferência do Paciente/economia , Kit de Reagentes para Diagnóstico/economia , Kit de Reagentes para Diagnóstico/provisão & distribuição , Autorrelato , África do Sul , Adulto Jovem
8.
J Med Virol ; 91(7): 1342-1350, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30854653

RESUMO

Low-cost, accurate high-risk human papillomavirus (HR-HPV) tests are needed for cervical cancer screening in limited-resource settings. More than 200 cervical cytological specimens from hospital patients were collected and analyzed for a real-world study. We evaluated the analytical and clinical performance of four widely used HR-HPV test (Tellgen, Hybribio, Liferiver, and Sansure) based on real-time polymerase chain reaction technology platforms, compared with the cobas test. Cervical intraepithelial neoplasia grade 2 or worse lesions (CIN2+) were set as the disease endpoint, and all the five HPV tests were performed with equal sensitivity (McNemar's test; P = 0.971) and specificity (McNemar's test; P = 0.953). All genotyping using the INNO-LiPA HPV test showed that HPV-16, -52, and -54 were the most common types among CIN2+ cases. Overall, the four HR-HPV tests analyzed appear to be as effective as the cobas HPV test in both agreement and clinical performance. Therefore, each of these low-cost HPV test kits could be implemented in limited-resource settings to accelerate the control of cervical cancer. However, we suggest that there is a need to further standardize and optimize testing around clinical sensitivity and specificity.


Assuntos
Técnicas de Laboratório Clínico/normas , Detecção Precoce de Câncer/métodos , Recursos em Saúde , Infecções por Papillomavirus/diagnóstico , Displasia do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/diagnóstico , Adulto , Idoso , Colo do Útero/patologia , Colo do Útero/virologia , Técnicas de Laboratório Clínico/economia , Técnicas de Laboratório Clínico/métodos , Detecção Precoce de Câncer/instrumentação , Feminino , Humanos , Pessoa de Meia-Idade , Papillomaviridae/genética , Infecções por Papillomavirus/virologia , Kit de Reagentes para Diagnóstico/economia , Kit de Reagentes para Diagnóstico/normas , Sensibilidade e Especificidade , Neoplasias do Colo do Útero/virologia , Adulto Jovem , Displasia do Colo do Útero/virologia
9.
J Korean Med Sci ; 33(46): e304, 2018 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-30416412

RESUMO

BACKGROUND: The Republic of Korea has a very low prevalence of human immunodeficiency virus (HIV) infection, but the number of new HIV diagnoses has steadily risen, strongly indicating a large number of undetected HIV infections. Thus, it is important for Korean public health authorities to adopt and encourage cost-effective HIV detection tools, such as rapid HIV screening tests. In this study, we aimed to evaluate the cost-effectiveness of enzyme-linked immunosorbent assays (ELISA) and rapid tests in a public health center (PHC) setting. METHODS: We developed a decision analytic model to assess the per-examinee cost and the cost-effectiveness of identifying HIV patients in a PHC setting using two HIV testing strategies: conventional HIV screening by ELISA versus rapid HIV testing. Analysis was performed in two scenarios: HIV testing in an average-risk population and in a high-risk population. RESULTS: Compared to the ELISA, the rapid test was cost-saving and cost-effective. The per-examinee cost was USD 1.61 with rapid testing versus USD 3.38 with ELISA in an average-risk population, and USD 4.77 with rapid testing versus USD 7.62 with ELISA in a high-risk population. The cost of identifying a previously undiagnosed HIV case was USD 26,974 with rapid testing versus USD 42,237 with ELISA in an average-risk population, and USD 153 with rapid testing versus USD 183 with ELISA in a high-risk population. CONCLUSION: Rapid testing would be more cost-effective than using conventional ELISA testing for identifying previously undiagnosed HIV-infected cases in Korea, a country with extremely low HIV prevalence.


Assuntos
Infecções por HIV/economia , Programas de Rastreamento/economia , Sorodiagnóstico da AIDS/economia , Análise Custo-Benefício , Tomada de Decisões , Ensaio de Imunoadsorção Enzimática/economia , Infecções por HIV/epidemiologia , Humanos , Prevalência , Saúde Pública , Kit de Reagentes para Diagnóstico/economia , República da Coreia , Risco , Testes Sorológicos
10.
Trials ; 18(1): 349, 2017 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-28738857

RESUMO

BACKGROUND: Despite large-scale efforts to diagnose people living with HIV, 54% remain undiagnosed in sub-Saharan Africa. The gap in knowledge of HIV status and uptake of follow-on services remains wide with much lower rates of HIV testing among men compared to women. Here, we design a study to investigate the effect on uptake of HIV testing and linkage into care or prevention of partner-delivered HIV self-testing alone or with an additional intervention among male partners of pregnant women. METHODS: A phase II, adaptive, multi-arm, multi-stage cluster randomised trial, randomising antenatal clinic (ANC) days to six different trial arms. Pregnant women accessing ANC in urban Malawi for the first time will be recruited into either the standard of care (SOC) arm (invitation letter to the male partner offering HIV testing) or one of five intervention arms offering oral HIV self-test kits. Three of the five intervention arms will additionally offer the male partner a financial incentive (fixed or lottery amount) conditional on linkage after self-testing with one arm testing phone call reminders. Assuming that 25% of male partners link to care or prevention in the SOC arm, six clinic days, with a harmonic mean of 21 eligible participants, per arm will provide 80% power to detect a 0.15 absolute difference in the primary outcome. Cluster proportions will be analysed by a cluster summaries approach with adjustment for clustering and multiplicity. DISCUSSION: This trial applies adaptive methods which are novel and efficient designs. The methodology and lessons learned here will be important as proof of concept of how to design and conduct similar studies in the future. Although small, this trial will potentially present good evidence on the type of effective interventions for improving linkage into ART or prevention. The trial results will also have important policy implications on how to implement HIVST targeting male partners of pregnant women who are accessing ANC for the first time while paying particular attention to safety concerns. Contamination may occur if women in the intervention arms share their self-test kits with women in the SOC arm. TRIAL REGISTRATION: ISRCTN, ID: 18421340 . Registered on 31 March 2016.


Assuntos
Infecções por HIV/diagnóstico , Programas de Rastreamento/métodos , Aceitação pelo Paciente de Cuidados de Saúde , Cuidado Pré-Natal , Kit de Reagentes para Diagnóstico , Autocuidado/métodos , Parceiros Sexuais , Cônjuges , Protocolos Clínicos , Feminino , Infecções por HIV/economia , Infecções por HIV/prevenção & controle , Infecções por HIV/transmissão , Humanos , Malaui , Masculino , Programas de Rastreamento/economia , Motivação , Valor Preditivo dos Testes , Gravidez , Kit de Reagentes para Diagnóstico/economia , Sistemas de Alerta , Projetos de Pesquisa , Autocuidado/economia , Telefone , Reforço por Recompensa
11.
AIDS Behav ; 21(2): 515-524, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27804092

RESUMO

We conducted an in-person survey of New York City (NYC) pharmacies to assess the availability, accessibility, and price of the over-the-counter, rapid HIV self-test kit. NYC pharmacies were stratified into high, moderate and low morbidity neighborhoods by the HIV diagnosis rate of the neighborhood in which the pharmacy was located. A random sample of 500 pharmacies was taken [250 from high morbidity neighborhoods (HighMN) and 250 from low morbidity neighborhoods (LowMN)]. Pharmacies were excluded if: closed during survey, non-retail, or >10 min walk from subway. Project staff visited pharmacies to determine kit availability (in pharmacy on day of survey), accessibility (not locked/behind counter), and price (marked on shelf/product). Of 361 pharmacies (161 LowMN; 200 HighMN), kits were available in 27 % and accessible in 10 %; there was no difference by neighborhood. Kits were most often kept behind the pharmacy counter; this was more common in HighMN than in LowMN. Kits were kept solely behind the pharmacy counter in 52 %. Median price was US $42.99 without variability across neighborhoods. The rapid HIV self-test had limited availability and access in retail pharmacies. The high median price measured suggests that cost remained a barrier.


Assuntos
Custos e Análise de Custo , Triagem e Testes Direto ao Consumidor/provisão & distribuição , Infecções por HIV/diagnóstico , Acessibilidade aos Serviços de Saúde , Farmácias , Kit de Reagentes para Diagnóstico/provisão & distribuição , Características de Residência , Triagem e Testes Direto ao Consumidor/economia , Humanos , Programas de Rastreamento , Cidade de Nova Iorque , Kit de Reagentes para Diagnóstico/economia
13.
PLoS Negl Trop Dis ; 10(8): e0004894, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27504954

RESUMO

BACKGROUND: A key epidemiologic feature of schistosomiasis is its focal distribution, which has important implications for the spatial targeting of preventive chemotherapy programs. We evaluated the diagnostic accuracy of a urine pooling strategy using a point-of-care circulating cathodic antigen (POC-CCA) cassette test for detection of Schistosoma mansoni, and employed simulation modeling to test the classification accuracy and efficiency of this strategy in determining where preventive chemotherapy is needed in low-endemicity settings. METHODOLOGY: We performed a cross-sectional study involving 114 children aged 6-15 years in six neighborhoods in Azaguié Ahoua, south Côte d'Ivoire to characterize the sensitivity and specificity of the POC-CCA cassette test with urine samples that were tested individually and in pools of 4, 8, and 12. We used a Bayesian latent class model to estimate test characteristics for individual POC-CCA and quadruplicate Kato-Katz thick smears on stool samples. We then developed a microsimulation model and used lot quality assurance sampling to test the performance, number of tests, and total cost per school for each pooled testing strategy to predict the binary need for school-based preventive chemotherapy using a 10% prevalence threshold for treatment. PRINCIPAL FINDINGS: The sensitivity of the urine pooling strategy for S. mansoni diagnosis using pool sizes of 4, 8, and 12 was 85.9%, 79.5%, and 65.4%, respectively, when POC-CCA trace results were considered positive, and 61.5%, 47.4%, and 30.8% when POC-CCA trace results were considered negative. The modeled specificity ranged from 94.0-97.7% for the urine pooling strategies (when POC-CCA trace results were considered negative). The urine pooling strategy, regardless of the pool size, gave comparable and often superior classification performance to stool microscopy for the same number of tests. The urine pooling strategy with a pool size of 4 reduced the number of tests and total cost compared to classical stool microscopy. CONCLUSIONS/SIGNIFICANCE: This study introduces a method for rapid and efficient S. mansoni prevalence estimation through examining pooled urine samples with POC-CCA as an alternative to widely used stool microscopy.


Assuntos
Antígenos de Helmintos/urina , Sistemas Automatizados de Assistência Junto ao Leito , Schistosoma/isolamento & purificação , Esquistossomose/epidemiologia , Urina/parasitologia , Adolescente , Animais , Teorema de Bayes , Quimioprevenção/instrumentação , Quimioprevenção/métodos , Criança , Côte d'Ivoire/epidemiologia , Estudos Transversais , Feminino , Humanos , Amostragem para Garantia da Qualidade de Lotes , Masculino , Prevalência , Kit de Reagentes para Diagnóstico/economia , Schistosoma/imunologia , Esquistossomose/classificação , Esquistossomose/parasitologia , Instituições Acadêmicas/economia , Instituições Acadêmicas/estatística & dados numéricos , Sensibilidade e Especificidade
14.
J Virol Methods ; 234: 80-6, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27091098

RESUMO

BACKGROUND: Quantitative, viral load monitoring for BK virus (BKV) by real-time PCR is an important tool in the management of polyomavirus associated nephropathy in renal transplant patients. However, variability in PCR results has been reported because of polymorphisms in viral genes among different subtypes of BKV, and lack of standardization of the PCR assays among different laboratories. In this study we have compared the performance of several laboratory developed PCR assays that target highly conserved regions of BKV genome with a commercially available, RealStar(®) BKV PCR Kit. METHOD: Three real-time PCR assays (i) VP1 assay: selected from the literature that targets the major capsid protein (VP1) gene (ii) VP1MOD assay: VP1 assay with a modified probe, and (iii) BKLTA assay: newly designed assay that targets the large T antigen gene were assessed in parallel, using controls and clinical specimens that were previously tested using RealStar(®) BKV PCR Kit (Altona Diagnostics GmbH, Hamburg, Germany). Nucleic acid from all samples were extracted using the QIA symphony virus/bacteria kit on an automated DNA extraction platform QIA symphony SP (Qiagen). Primer and probe concentration, and reaction conditions for laboratory developed assays were optimized and the limit of detection of different assays was determined. Positive control for laboratory developed BK assays was prepared through construction of a plasmid carrying respective amplicon sequences. RESULTS: The 95% detection limit of VP1, VP1MOD and BKLTA assays were 1.8×10(2), 3×10(3) and 3.5×10(2) genomic copies/ml, respectively, as determined by Probit regression analysis of data obtained by testing a dilution series of a titered patient specimen, using RealStar(®) BKV PCR Kit. The inter-assay and intra-assay, coefficient of variations of these assays using calibrated, plasmid standards were <1%. All assays, including the RealStar(®) BKV PCR assay, were highly specific when tested against a panel of external proficiency specimens containing both BK and JC viruses. All assays, except the VP1MOD assay determined BK viral load in proficiency specimens within the same log values. With reference to results obtained by RealStar(®) BKV PCR assay, the sensitivity and specificity of different assays tested in 116 serum specimens submitted for BK viral load assay were 91% and 97% for VP1 assay, 88% and 97% for VP1MOD assay, and 97% and 98% for BKLTA assay, respectively. BK Viral load in positive specimens determined by various assays was highly correlated (R(2)>0.97), based on linear regression analysis. CONCLUSIONS: The performance characteristics of the newly designed, BKLTA assay were highly comparable to RealStar(®) BKV PCR assay, and can be used for routine detection and viral load monitoring of BKV in a cost-effective manner.


Assuntos
Vírus BK/isolamento & purificação , Infecções por Polyomavirus/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real , Carga Viral , Antígenos Virais de Tumores/genética , Vírus BK/genética , Proteínas do Capsídeo/genética , Primers do DNA , DNA Viral/sangue , Genoma Viral , Humanos , Nefropatias/diagnóstico , Nefropatias/virologia , Limite de Detecção , Ácidos Nucleicos/genética , Infecções por Polyomavirus/virologia , Kit de Reagentes para Diagnóstico/economia , Reação em Cadeia da Polimerase em Tempo Real/economia , Reação em Cadeia da Polimerase em Tempo Real/métodos
15.
Curr HIV/AIDS Rep ; 13(2): 107-15, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26879653

RESUMO

Oral HIV self-testing is an innovative and potentially high-impact means to increase HIV-case identification globally. As a screening test, oral HIV self-testing offers the potential for increased adoption through greater convenience and privacy, and the potential to increase the proportion of the population who test regularly. Research on how best to translate the innovation of oral self-testing to high-risk populations is underway. Currently only one oral HIV self-test kit is FDA-approved (OraQuick In-Home HIV Test) and available for retail sale. In the present report we review recent studies on the dissemination, adoption, and implementation of oral HIV testing. Prior work has focused primarily on adoption, but recent studies have begun to identify methods for improving dissemination and problems associated with self-implementation. At present a major barrier to wider adoption is the relatively high retail cost of the oral HIV test kit. Significant but minor barriers are represented by overly complex instructional materials for some population segments, and dissemination programs of unknown efficacy. Theoretical and practical suggestions for conducting research on dissemination, adoption, and implementation of oral HIV testing are discussed.


Assuntos
Infecções por HIV/diagnóstico , Infecções por HIV/prevenção & controle , Soropositividade para HIV/diagnóstico , Programas de Rastreamento/métodos , Kit de Reagentes para Diagnóstico/estatística & dados numéricos , Autoexame/métodos , Homossexualidade Masculina , Humanos , Masculino , Kit de Reagentes para Diagnóstico/economia
16.
Sex Transm Infect ; 92(5): 340-6, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26920867

RESUMO

OBJECTIVES: The WHO called for the elimination of maternal-to-child transmission (MTCT) of HIV and syphilis, a harmonised approach for the improvement of health outcomes for mothers and children. Testing early in pregnancy, treating seropositive pregnant women and preventing syphilis reinfection can prevent MTCT of HIV and syphilis. We assessed the health and economic outcomes of a dual testing strategy in a simulated cohort of 100 000 antenatal care patients in Malawi. METHODS: We compared four screening algorithms: (1) HIV rapid test only, (2) dual HIV and syphilis rapid tests, (3) single rapid tests for HIV and syphilis and (4) HIV rapid and syphilis laboratory tests. We calculated the expected number of adverse pregnancy outcomes, the expected costs and the expected newborn disability-adjusted life years (DALYs) for each screening algorithm. The estimated costs and DALYs for each screening algorithm were assessed from a societal perspective using Markov progression models. Additionally, we conducted a Monte Carlo multiway sensitivity analysis, allowing for ranges of inputs. RESULTS: Our cohort decision model predicted the lowest number of adverse pregnancy outcomes in the dual HIV and syphilis rapid test strategy. Additionally, from the societal perspective, the costs of prevention and care using a dual HIV and syphilis rapid testing strategy was both the least costly ($226.92 per pregnancy) and resulted in the fewest DALYs (116 639) per 100 000 pregnancies. In the Monte Carlo simulation the dual HIV and syphilis algorithm was always cost saving and almost always reduced DALYs compared with HIV testing alone. CONCLUSIONS: The results of the cost-effectiveness analysis showed that a dual HIV and syphilis test was cost saving compared with all other screening strategies. Updating existing prevention of mother-to-child HIV transmission programmes in Malawi and similar countries to include dual rapid testing for HIV and syphilis is likely to be advantageous.


Assuntos
Algoritmos , Infecções por HIV/diagnóstico , Transmissão Vertical de Doenças Infecciosas/prevenção & controle , Programas de Rastreamento/economia , Complicações Infecciosas na Gravidez/diagnóstico , Cuidado Pré-Natal/economia , Diagnóstico Pré-Natal/economia , Sífilis/diagnóstico , Adulto , Análise Custo-Benefício , Feminino , Infecções por HIV/economia , Infecções por HIV/prevenção & controle , Infecções por HIV/transmissão , Humanos , Recém-Nascido , Transmissão Vertical de Doenças Infecciosas/economia , Malaui , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Gravidez , Complicações Infecciosas na Gravidez/economia , Complicações Infecciosas na Gravidez/prevenção & controle , Resultado da Gravidez , Kit de Reagentes para Diagnóstico/economia , Sífilis/economia , Sífilis/prevenção & controle , Sífilis/transmissão
17.
J Med Toxicol ; 12(2): 172-9, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26553280

RESUMO

Ethylene glycol (EG) is a common cause of toxic ingestions. Gas chromatography (GC)-based laboratory assays are the gold standard for diagnosing EG intoxication. However, GC requires specialized instrumentation and technical expertise that limits feasibility for many clinical laboratories. The objective of this retrospective study was to determine the utility of incorporating a rapid EG assay for management of cases with suspected EG poisoning. The University of Iowa Hospitals and Clinics core clinical laboratory adapted a veterinary EG assay (Catachem, Inc.) for the Roche Diagnostics cobas 8000 c502 analyzer and incorporated this assay in an osmolal gap-based algorithm for potential toxic alcohol/glycol ingestions. The main limitation is that high concentrations of propylene glycol (PG), while readily identifiable by reaction rate kinetics, can interfere with EG measurement. The clinical laboratory had the ability to perform GC for EG and PG, if needed. A total of 222 rapid EG and 24 EG/PG GC analyses were documented in 106 patient encounters. Of ten confirmed EG ingestions, eight cases were managed entirely with the rapid EG assay. PG interference was evident in 25 samples, leading to 8 GC analyses to rule out the presence of EG. Chart review of cases with negative rapid EG assay results showed no evidence of false negatives. The results of this study highlight the use of incorporating a rapid EG assay for the diagnosis and management of suspected EG toxicity by decreasing the reliance on GC. Future improvements would involve rapid EG assays that completely avoid interference by PG.


Assuntos
Etilenoglicol/sangue , Intoxicação/sangue , Padrões de Prática Médica , Kit de Reagentes para Diagnóstico , Centros Médicos Acadêmicos , Adulto , Algoritmos , Diagnóstico Diferencial , Registros Eletrônicos de Saúde , Etilenoglicol/intoxicação , Feminino , Ionização de Chama/economia , Custos Hospitalares , Humanos , Iowa , Masculino , Pessoa de Meia-Idade , Intoxicação/diagnóstico , Intoxicação/economia , Intoxicação/terapia , Padrões de Prática Médica/economia , Propilenoglicol/sangue , Propilenoglicol/intoxicação , Kit de Reagentes para Diagnóstico/economia , Kit de Reagentes para Diagnóstico/veterinária , Estudos Retrospectivos , Fatores de Tempo , Toxicocinética
18.
Expert Rev Mol Diagn ; 15(5): 589-96, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25896578

RESUMO

Lung cancer is the most common cause of cancer death in the USA. Patients with early-stage non-small-cell lung cancer have a 5-year survival of approximately 70%. Effective, accurate and clinically relevant prognostic tests are needed to determine which patients are at high risk of disease-specific mortality after surgical resection. Currently, there are two commercially available prognostic tests based on differential gene expression for this purpose: the Myriad myPlan™ Lung Cancer and Pervenio™ Lung RS tests. One stratifies patients into two risk groups and the other into three risk groups. Both have been validated in independent patient cohorts and neither has yet been demonstrated to improve survival. These tests have the potential to risk-stratify which patients with early-stage lung cancer will have a higher likelihood of disease recurrence after surgical resection and may benefit from adjuvant treatment.


Assuntos
Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Técnicas de Diagnóstico Molecular , Kit de Reagentes para Diagnóstico , Biomarcadores Tumorais/genética , Humanos , Neoplasias Pulmonares/patologia , Técnicas de Diagnóstico Molecular/economia , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Estadiamento de Neoplasias , Prognóstico , Kit de Reagentes para Diagnóstico/economia , Kit de Reagentes para Diagnóstico/normas
19.
Rev Chilena Infectol ; 32(1): 117-9, 2015 Feb.
Artigo em Espanhol | MEDLINE | ID: mdl-25860056

RESUMO

The diagnosis of invasive aspergillosis remains a challenge. Detection of galactomannan in serum and bronchoalveolar lavage is a useful tool; however due to methodological and economic reasons, the test frequencies of galactomannan assays vary from daily to weekly, which constitute a risk to the patient. In this study, we aimed to evaluate and correlate the performance of the new kit Aspergillus-LFD with the GM-EIA. Aspergillus-LFD kit represents a fast, economical and simple test; showed a good performance and excellent correlation with GM-EIA kit. Given the above, the Aspergillus-LFD is emerging as an alternative to consider in the early diagnosis of invasive aspergillosis.


Assuntos
Aspergilose/diagnóstico , Aspergillus/isolamento & purificação , Cromatografia de Afinidade/instrumentação , Técnicas Imunoenzimáticas/instrumentação , Mananas/análise , Kit de Reagentes para Diagnóstico , Biomarcadores/sangue , Chile , Cromatografia de Afinidade/economia , Galactose/análogos & derivados , Humanos , Técnicas Imunoenzimáticas/economia , Kit de Reagentes para Diagnóstico/economia , Sensibilidade e Especificidade , Fatores de Tempo
20.
Expert Rev Mol Diagn ; 15(4): 491-503, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25711191

RESUMO

Limitations with current clinical tools available for diagnosis and prognosis of prostate cancer (PCa) have resulted in overdiagnosis and costly overtreatment, which is affecting the outcomes and quality of life of men. The biotech industry is investing significant resources into developing more specific biomarkers for PCa detection and patient stratification that would greatly advance the decision-making processes behind PCa management and treatment. In this review, we focus on those biomarkers that have been translated into commercial tests available to clinicians. Since these tests aim to fill specific gaps during the decision-making process of PCa management, we have grouped them based on the clinical question they claim to address, that is, improved PCa screening, false-negative biopsy dilemma, prognostic tests following a positive biopsy and tests predicting relapse/metastases after surgery. We evaluate each test with respect to its development, platform, clinical validation, biomatrix, regulatory approval status and cost.


Assuntos
Biomarcadores Tumorais , Neoplasias da Próstata/diagnóstico , Kit de Reagentes para Diagnóstico , Biomarcadores Tumorais/genética , Biomarcadores Tumorais/metabolismo , Biópsia , Humanos , Masculino , Programas de Rastreamento/economia , Programas de Rastreamento/métodos , Programas de Rastreamento/normas , Prognóstico , Neoplasias da Próstata/genética , Neoplasias da Próstata/metabolismo , Kit de Reagentes para Diagnóstico/economia , Kit de Reagentes para Diagnóstico/normas , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA