Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.614
Filtrar
1.
BMC Anesthesiol ; 24(1): 142, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609865

RESUMO

BACKGROUND: The objective of this study was to evaluate a modern combined video laryngoscopy and flexible fiberoptic bronchoscope approach to placement of a double lumen endobronchial tube and further characterize potential strengths and weaknesses of this approach. METHODS: Retrospective chart review was conducted at our single institution, academic medical center, tertiary-care hospital. Patients aged 18 years of age or older were evaluated who underwent thoracic surgery and one-lung ventilation with placement of a double lumen endobronchial tube using a novel combined video laryngoscopy and flexible fiberoptic bronchoscope approach. No interventions were performed. RESULTS: Demographics and induction and intubation documentation were reviewed for 21 patients who underwent thoracic surgery and one-lung ventilation with placement of a double lumen endobronchial tube using a novel combined video laryngoscopy and flexible fiberoptic bronchoscope approach. First pass success using the combined approach was 86% (18/21). The five patients with an anticipated difficult airway had successful double lumen endobronchial tube placement on the first attempt. There were no instances of desaturation during double lumen endobronchial tube placement. No airway complications related to double lumen endobronchial tube placement were recorded. CONCLUSION: Use of a combined approach employing video laryngoscopy and a flexible fiberoptic bronchoscope may represent a reliable alternative approach to placement of double lumen endobronchial tubes.


Assuntos
Laringoscópios , Ventilação Monopulmonar , Humanos , Adolescente , Adulto , Idoso , Estudos Retrospectivos , Laringoscopia , Intubação
4.
Vet Anaesth Analg ; 51(3): 266-270, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38565449

RESUMO

OBJECTIVE: To develop and evaluate a low-cost three-dimensional (3D)-printed video laryngoscope (VLVET) for use with a commercial borescope. STUDY DESIGN: Instrument development and pilot study. ANIMALS: A total of six adult male Beagle dogs. METHODS: The VLVET consisted of a laryngoscope handle and a Miller-type blade, and a detachable camera holder that attached to various locations along the blade. The laryngoscope and camera holder were 3D-printed using black polylactic acid filament. Dogs were premedicated with intravenous (IV) medetomidine (15 µg kg-1) and anesthesia induced with IV alfaxalone (1.5 mg kg-1). The VLVET, combined with a borescope, was used for laryngeal visualization and intubation. Performance was evaluated by comparing direct and video-assisted views in sternal recumbency. The borescope camera was sequentially positioned at 2, 4, 6, 8 and 10 cm from the blade tip (distanceLARYNX-CAM), which was placed on the epiglottis during intubation or laryngoscopy. At the 10 cm distanceLARYNX-CAM, laryngeal visualization was sequentially scored at inter-incisor gaps of 10, 8, 6, 4 and 2 cm. Laryngeal visualization scores (0-3 range, with 0 = obstructed and 3 = unobstructed views) were statistically analyzed using the Friedman's test. RESULTS: Under direct visualization, the 2 cm distanceLARYNX-CAM had a significantly lower score compared with all other distanceLARYNX-CAM (all p = 0.014) because the view was obstructed by the camera holder and borescope camera. With both direct and camera-assisted views, visualization scores were higher at inter-incisor gaps ≥ 4 cm compared with 2 cm (all p < 0.05). CONCLUSIONS AND CLINICAL RELEVANCE: During laryngoscopy and intubation, the VLVET and borescope facilitated both direct and video laryngoscopy at distanceLARYNX-CAM in Beagle dogs when inter-incisor gaps were ≥ 4 cm.


Assuntos
Intubação Intratraqueal , Laringoscópios , Impressão Tridimensional , Animais , Cães , Laringoscópios/veterinária , Masculino , Intubação Intratraqueal/veterinária , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Gravação em Vídeo , Laringoscopia/veterinária , Laringoscopia/métodos , Laringoscopia/instrumentação , Projetos Piloto , Desenho de Equipamento
5.
BMJ Case Rep ; 17(4)2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575332

RESUMO

Missing and loose central incisors pose a great difficulty to anaesthesiologists during laryngoscopy and intubation. Left head rotation is a novel technique which facilitates intubation by improving the laryngoscopic view. We report the use of this technique in two patients with missing or loose central incisors to prevent dental trauma.


Assuntos
Intubação Intratraqueal , Laringoscópios , Humanos , Intubação Intratraqueal/métodos , Laringoscopia/métodos
6.
Transfusion ; 64 Suppl 2: S201-S209, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38545924

RESUMO

INTRODUCTION: Video laryngoscope (VL) technology improves first-pass success. The novel i-view VL device is inexpensive and disposable. We sought to determine the first-pass intubation success with the i-view VL device versus the standard reusable VL systems in routine use at each site. METHODS: We performed a prospective, pragmatic study at two major emergency departments (EDs) when VL was used. We rotated i-view versus reusable VL as the preferred device of the month based on an a priori schedule. An investigator-initiated interim analysis was performed. Our primary outcome was a first-pass success with a non-inferiority margin of 10% based on the per-protocol analysis. RESULTS: There were 93 intubations using the reusable VL devices and 81 intubations using the i-view. Our study was stopped early due to futility in reaching our predetermined non-inferiority margin. Operator and patient characteristics were similar between the two groups. The first-pass success rate for the i-view group was 69.1% compared to 84.3% for the reusable VL group. A non-inferiority analysis indicated that the difference (-15.1%) and corresponding 90% confidence limits (-25.3% to -5.0%) did not fall within the predetermined 10% non-inferiority margin. CONCLUSIONS: The i-view device failed to meet our predetermined non-inferiority margin when compared to the reusable VL systems with the study stopping early due to futility. Significant crossover occurred at the discretion of the intubating operator during the i-view month.


Assuntos
Intubação Intratraqueal , Laringoscópios , Humanos , Estudos Prospectivos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Serviço Hospitalar de Emergência , Reutilização de Equipamento , Laringoscopia/métodos , Laringoscopia/instrumentação
7.
JAMA ; 331(15): 1279-1286, 2024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38497992

RESUMO

Importance: Endotracheal tubes are typically inserted in the operating room using direct laryngoscopy. Video laryngoscopy has been reported to improve airway visualization; however, whether improved visualization reduces intubation attempts in surgical patients is unclear. Objective: To determine whether the number of intubation attempts per surgical procedure is lower when initial laryngoscopy is performed using video laryngoscopy or direct laryngoscopy. Design, Setting, and Participants: Cluster randomized multiple crossover clinical trial conducted at a single US academic hospital. Patients were adults aged 18 years or older having elective or emergent cardiac, thoracic, or vascular surgical procedures who required single-lumen endotracheal intubation for general anesthesia. Patients were enrolled from March 30, 2021, to December 31, 2022. Data analysis was based on intention to treat. Interventions: Two sets of 11 operating rooms were randomized on a 1-week basis to perform hyperangulated video laryngoscopy or direct laryngoscopy for the initial intubation attempt. Main Outcomes and Measures: The primary outcome was the number of operating room intubation attempts per surgical procedure. Secondary outcomes were intubation failure, defined as the responsible clinician switching to an alternative laryngoscopy device for any reason at any time, or by more than 3 intubation attempts, and a composite of airway and dental injuries. Results: Among 8429 surgical procedures in 7736 patients, the median patient age was 66 (IQR, 56-73) years, 35% (2950) were women, and 85% (7135) had elective surgical procedures. More than 1 intubation attempt was required in 77 of 4413 surgical procedures (1.7%) randomized to receive video laryngoscopy vs 306 of 4016 surgical procedures (7.6%) randomized to receive direct laryngoscopy, with an estimated proportional odds ratio for the number of intubation attempts of 0.20 (95% CI, 0.14-0.28; P < .001). Intubation failure occurred in 12 of 4413 surgical procedures (0.27%) using video laryngoscopy vs 161 of 4016 surgical procedures (4.0%) using direct laryngoscopy (relative risk, 0.06; 95% CI, 0.03-0.14; P < .001) with an unadjusted absolute risk difference of -3.7% (95% CI, -4.4% to -3.2%). Airway and dental injuries did not differ significantly between video laryngoscopy (41 injuries [0.93%]) vs direct laryngoscopy (42 injuries [1.1%]). Conclusion and Relevance: In this study among adults having surgical procedures who required single-lumen endotracheal intubation for general anesthesia, hyperangulated video laryngoscopy decreased the number of attempts needed to achieve endotracheal intubation compared with direct laryngoscopy at a single academic medical center in the US. Results suggest that video laryngoscopy may be a preferable approach for intubating patients undergoing surgical procedures. Trial Registration: ClinicalTrials.gov Identifier: NCT04701762.


Assuntos
Intubação Intratraqueal , Laringoscópios , Laringoscopia , Feminino , Humanos , Masculino , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/métodos , Laringoscopia/efeitos adversos , Laringoscopia/métodos , Salas Cirúrgicas , Traumatismos Dentários/etiologia , Gravação em Vídeo , Procedimentos Cirúrgicos Operatórios , Estudos Cross-Over , Pessoa de Meia-Idade , Idoso , Centros Médicos Acadêmicos
9.
Kobe J Med Sci ; 69(4): E151-E158, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38462525

RESUMO

Endotracheal intubation (ETI) is a common and crucial intervention. Whether the performance of ETI differs according to the sex of the laryngoscopist remains unclear. The aim of this study was to assess sex disparities in markers of ETI performance among novices using a high-fidelity simulator. This prospective observational study was conducted from April 2017 to March 2019 in a public medical university. In total, 209 medical students (4th and 5th grade) without clinical ETI experience were recruited. Of the 209 students, 64 (30.6%) were female. The participants used either a Macintosh direct laryngoscope or C-MAC video laryngoscope in combination with a stylet or gum-elastic bougie to perform ETI on a high-fidelity simulator. The primary endpoint was the maximum force applied on the maxillary incisors during laryngoscopy. The secondary endpoint was the time to ETI. The implanted sensors in the simulator automatically quantified the force and time to ETI. The maximum force applied on the maxillary incisors was approximately 30% lower in the male than female group for all laryngoscopes and intubation aids examined (all P < 0.001). Similarly, the time to ETI was approximately 10% faster in the male than female group regardless of the types of laryngoscopes and intubation aids used (all P < 0.05). In this study, male sex was associated with a lower maximum force applied on the maxillary incisors during both direct and indirect laryngoscopy performed by novices. A clinical study focusing on sex differences in ETI performance is needed to validate our findings.


Assuntos
Laringoscópios , Laringoscopia , Humanos , Masculino , Feminino , Incisivo , Intubação Intratraqueal , Estudos Prospectivos
12.
Syst Rev ; 13(1): 85, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38475918

RESUMO

BACKGROUND: Intubating a patient in an emergent setting presents significant challenges compared to planned intubation in an operating room. This study aims to compare video laryngoscopy versus direct laryngoscopy in achieving successful endotracheal intubation on the first attempt in emergency intubations, irrespective of the clinical setting. METHODS: We systematically searched PubMed, Scopus, Web of Science, and the Cochrane Central Register of Controlled Trials from inception until 27 February 2023. We included only randomized controlled trials that included patients who had undergone emergent endotracheal intubation for any indication, regardless of the clinical setting. We used the Cochrane risk-of-bias assessment tool 2 (ROB2) to assess the included studies. We used the mean difference (MD) and risk ratio (RR), with the corresponding 95% confidence interval (CI), to pool the continuous and dichotomous variables, respectively. RESULTS: Fourteen studies were included with a total of 2470 patients. The overall analysis favored video laryngoscopy over direct laryngoscopy in first-attempt success rate (RR = 1.09, 95% CI [1.02, 1.18], P = 0.02), first-attempt intubation time (MD = - 6.92, 95% CI [- 12.86, - 0.99], P = 0.02), intubation difficulty score (MD = - 0.62, 95% CI [- 0.86, - 0.37], P < 0.001), peri-intubation percentage of glottis opening (MD = 24.91, 95% CI [11.18, 38.64], P < 0.001), upper airway injuries (RR = 0.15, 95% CI [0.04, 0.56], P = 0.005), and esophageal intubation (RR = 0.37, 95% CI [0.15, 0.94], P = 0.04). However, no difference between the two groups was found regarding the overall intubation success rate (P > 0.05). CONCLUSION: In emergency intubations, video laryngoscopy is preferred to direct laryngoscopy in achieving successful intubation on the first attempt and was associated with a lower incidence of complications.


Assuntos
Laringoscópios , Laringoscopia , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Intubação Intratraqueal , Registros , Gravação em Vídeo
13.
JAMA Otolaryngol Head Neck Surg ; 150(4): 342-348, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38451500

RESUMO

Importance: Endoscopes are paramount to the practice of otolaryngology. To provide physicians in low-middle-income countries with adequate tools to treat otolaryngologic problems, it is necessary to create a low-cost sustainable option. Objective: To describe the design and usability of an open-source, low-cost flexible laryngoscope that addresses the lack of affordable and accessible methods for otolaryngologic visualization in resource-limited settings. Design, Setting, and Participants: This quality improvement study used a mixed-methods approach, including a technical description of device design as well as quantitative and qualitative survey evaluation of device usability. Engineering involved device design, sourcing or manufacturing individual components, fabricating a prototype, and iterative testing. Key assumptions and needs for the device were identified in collaboration with otolaryngologists in Zimbabwe, and designed and simulated by biomedical engineers in a US university laboratory. Board-certified otolaryngologists at a single US university hospital trialed a completed prototype on simulated airways between May 2023 and June 2023. Main Outcomes and Measures: Technical details on the design of the device are provided. Otolaryngologist gave feedback on device characteristics, maneuverability, and visualization using the System Usability Scale, a customized Likert-scale questionnaire (5-point scale), and semistructured interviews. Results: A functional prototype meeting requirements was completed consisting of a distal-chip camera, spring bending tip, handle housing the control mechanism and electronics, and flexible polyether block amide-coated silicone sheath housing the camera and control wires; an external monitor provided real-time visualization and ability to store data. A total of 14 otolaryngologists participated in the device review. The mean (SD) System Usability Scale score was 88.93 (10.08), suggesting excellent usability. The device was rated highly for ease of set up, physical attributes, image quality, and functionality. Conclusions and Relevance: This quality improvement study described the design of a novel open-source low-cost flexible laryngoscope that external review with otolaryngologists suggests was usable and feasible in various resource-limited environments. Future work is needed to translate the model into a clinical setting.


Assuntos
Laringoscópios , Otolaringologia , Médicos , Humanos , Região de Recursos Limitados , Otorrinolaringologistas
14.
Sci Rep ; 14(1): 4980, 2024 02 29.
Artigo em Inglês | MEDLINE | ID: mdl-38424153

RESUMO

This observational study aimed to compare the glottic view between video and direct laryngoscopy for tracheal intubation in the surgical position for thyroid surgery with intraoperative neuromonitoring. Patients scheduled for elective thyroid surgery with intraoperative neuromonitoring were enrolled. After the induction of anesthesia, patients were positioned in the thyroid surgical posture with a standard inclined pillow under their head and back. An investigator assessed the glottic view using the percentage of glottic opening (POGO) scale and the modified Cormack-Lehane grade in direct laryngoscopy and then video laryngoscopy sequentially while using the same McGRATH™ MAC video laryngoscope at once, with or without external laryngeal manipulation, at the surgical position. A total of thirty-nine patients were participated in this study. Without external laryngeal manipulation, the POGO scale significantly improved during video laryngoscopy compared to direct laryngoscopy in the thyroid surgical position (60.0 ± 38.2% vs. 22.4 ± 23.8%; mean difference (MD) 37.6%, 95% confidence interval (CI) = [29.1, 46.0], P < 0.001). Additionally, with external laryngeal manipulation, the POGO scale showed a significant improvement during video laryngoscopy compared to direct laryngoscopy (84.6 ± 22.9% vs. 58.0 ± 36.3%; MD 26.7%, 95% CI = [18.4, 35.0] (P < 0.001). The superiority of video laryngoscopy was also observed for the modified Cormack-Lehane grade. In conclusion, video laryngoscopy with the McGRATH™ MAC video laryngoscope, when compared to direct laryngoscopy with it, improved the glottic view during tracheal intubation in the thyroid surgical position. This enhancement may potentially facilitate the proper placement of the electromyography tracheal tube and prevent tube displacement due to positional change for thyroid surgery.


Assuntos
Laringoscópios , Laringe , Humanos , Laringoscopia , Glândula Tireoide/cirurgia , Intubação Intratraqueal , Gravação em Vídeo
15.
Crit Care Nurs Q ; 47(2): 152-156, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38419178

RESUMO

Prehospital intubation is a high-risk, relatively low frequency procedure. Provider experience plays a key role in first-pass success rates, especially in the setting of a difficult airway. While strong foundational knowledge is necessary to equip providers with an adequate understanding of intubation procedures and the skill set needed to manage a difficult airway, effective equipment may provide an extra boost in first-pass success for novice airway providers. First-pass success is correlated with decreased adverse events and should be maximized in the prehospital setting. After evaluating overall first-pass success of 66% to 83% from 2016 to 2020, AHN LifeFlight enacted changes in education, training, and video laryngoscopy equipment to successfully increase first-pass success to over 90%.


Assuntos
Laringoscópios , Humanos , Intubação Intratraqueal/métodos , Laringoscopia/métodos , Competência Clínica
19.
Crit Care ; 28(1): 1, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167459

RESUMO

BACKGROUND: The utilization of video laryngoscopy (VL) has demonstrated superiority over direct laryngoscopy (DL) for intubation in surgical settings. However, its effectiveness in the intensive care unit and emergency department settings remains uncertain. METHODS: We systematically searched PubMed, Embase, Cochrane, and ClinicalTrials.gov databases for randomized controlled trials (RCTs) comparing VL versus DL in critically ill patients. Critical setting was defined as emergency department and intensive care unit. This systematic review and meta-analysis followed Cochrane and PRISMA recommendations. R version 4.3.1 was used for statistical analysis and heterogeneity was examined with I2 statistics. All outcomes were submitted to random-effect models. RESULTS: Our meta-analysis of 14 RCTs, compromising 3981 patients assigned to VL (n = 2002) or DL (n = 1979). Compared with DL, VL significantly increased successful intubations on the first attempt (RR 1.12; 95% CI 1.04-1.20; p < 0.01; I2 = 82%). Regarding adverse events, VL reduced the number of esophageal intubations (RR 0.44; 95% CI 0.24-0.80; p < 0.01; I2 = 0%) and incidence of aspiration episodes (RR 0.63; 95% CI 0.41-0.96; p = 0.03; I2 = 0%) compared to DL. CONCLUSION: VL is a more effective and safer strategy compared with DL for increasing successful intubations on the first attempt and reducing esophageal intubations in critically ill patients. Our findings support the routine use of VL in critically ill patients. Registration CRD42023439685 https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42023439685 . Registered 6 July 2023.


Assuntos
Laringoscópios , Laringoscopia , Humanos , Intubação Intratraqueal , Estado Terminal/terapia , Ensaios Clínicos Controlados Aleatórios como Assunto , Gravação em Vídeo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA