Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.575
Filtrar
1.
Rom J Ophthalmol ; 68(3): 330-334, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39464762

RESUMO

Introduction: Intra-ocular lens (IOL) calcification is a rare yet serious complication, presenting as clouding within the optics of IOL and necessitating IOL exchange. Patient and Clinical Findings: In this case, a 77-year-old male experienced gradual vision loss in his left eye (LE) over four years post-cataract surgery a decade before. His best corrected visual acuity (BCVA) was 3/60 in the LE, with the anterior segment displaying a clear cornea but an opacified IOL within the capsular bag. Ultrasound biomicroscopy (UBM) revealed hyperechoic reflections from the IOL in the LE. ImageJ software used on UBM images indicated a significant difference in optical density (OD) compared to the right eye (RE). Results: The patient was diagnosed with IOL calcification in LE, and underwent anterior vitrectomy and IOL exchange with sulcus-placed IOL with optic capture in the capsular bag, resulting in an improved visual acuity of 6/18. Microscopic examination of explanted IOL revealed whitish calcium carbonate crystal deposits on the IOL, which were visible under polarized light. Conclusions and significance: The innovative use of polarized light and ImageJ software can be used in resource-constraint settings to confirm the diagnosis in such cases. Based on ImageJ on the UBM image, OD can pick up even subtle changes in the optical clarity of the IOL optic preoperatively.


Assuntos
Calcinose , Lentes Intraoculares , Acuidade Visual , Humanos , Masculino , Idoso , Calcinose/diagnóstico , Calcinose/cirurgia , Lentes Intraoculares/efeitos adversos , Microscopia de Polarização/métodos , Microscopia Acústica/métodos , Vitrectomia/métodos , Doenças do Cristalino/diagnóstico , Doenças do Cristalino/etiologia , Doenças do Cristalino/cirurgia
2.
Transl Vis Sci Technol ; 13(10): 18, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39388178

RESUMO

Purpose: The purpose of this study was to investigate the impact of calcium and phosphorus levels on optical deterioration in primary and secondary intraocular lens (IOL) calcification. Methods: A total of 18 explanted IOLs, 10 with primary, and 8 with secondary calcification, were examined. Straylight and light loss were evaluated as predictors of optical impairment. The individual amount of calcium and phosphorus was determined using thermogravimetry followed by emission spectroscopy (ICP-OES). The relationship between calcification and optical impairment was investigated. Results: Primary calcified IOLs contained significantly higher amounts of calcium and phosphorus compared to secondary calcified IOLs (calcium P < 0.02 and phosphorus P < 0.01), translating to greater light loss and significantly higher straylight mean values. In secondary calcification, light loss and straylight were highly dependent on calcium (r² = 0.90, P < 0.001 and r² = 0.70, P < 0.01) and phosphorus (r² = 0.66 and r² = 0.65, both P < 0.02), whereas these correlations were much lower in primary calcification (all r = 0.25, P > 0.05). Conclusions: ICP-OES is the first methodology to precisely assess the calcium and phosphorus content in IOL calcification thus based on mass ratios allowing improved molecular characterization. Primary calcification showed higher amounts of calcium and phosphorus, translating to higher straylight and light loss and thus a higher risk for impairment of visual quality than secondary calcification. Translational Relevance: This study is the first to quantify calcification and demonstrate the relationship to optical deterioration in IOLs, substantially contributing to understand how visual impairment arises in patients with calcified IOLs.


Assuntos
Calcinose , Cálcio , Lentes Intraoculares , Fósforo , Fósforo/metabolismo , Humanos , Calcinose/metabolismo , Lentes Intraoculares/efeitos adversos , Cálcio/metabolismo , Cálcio/análise , Idoso , Feminino , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Idoso de 80 Anos ou mais
3.
Korean J Ophthalmol ; 38(5): 354-363, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39155136

RESUMO

PURPOSE: This study aimed to analyze the incidence and characteristics of intraocular lens (IOL) dislocation after cataract surgery in South Korea. METHODS: We retrospectively analyzed the incidence of IOL dislocation after cataract surgery in patients diagnosed between 2002 and 2021. Data of all pseudophakic patients who underwent secondary IOL or IOL exchange surgeries due to IOL dislocation were extracted from the Korean National Health Insurance System database and the Korean Standard Classification of Diseases 7th Revision codes. The incidence per 1,000,000 person-years and corresponding 95% confidence intervals (CIs) were calculated. RESULTS: Between 2002 and 2021, 39,965 of the 4,848,125 pseudophakic patients (0.82%) were diagnosed with IOL dislocation and surgically treated. The incidence of IOL dislocation requiring surgery in pseudophakic patients was 28,900 per 1,000,000 person-years (95% CI, 28,431-29,369), comprising 57,800 cases in male (95% CI, 56,730-58,870) and 10,800 in female patients (95% CI, 10,523-11,077), and the mean male to female ratio was 5.35. The incidence rate peaked in younger age group below 40 years, showing 107,000 per 1,000,000 person-years (95% CI, 102,900-111,100), and the average age of IOL dislocation requiring surgery was 68.1 ± 10.7 years. The average time lapse from cataract surgery to secondary IOL surgery due to IOL dislocation was 4.1 ± 4.7 years (median, 2.2 years), and the number of secondary IOL surgery due to dislocation of artificial lensrapidly occurred 10 years after cataract surgery among all age groups. CONCLUSIONS: The incidence of IOL dislocation requiring surgery was higher in younger and male patients. Our findings could be expected to aid establishing future healthcare policies for South Korean populations with an increased risk of IOL dislocation after cataract surgery.


Assuntos
Lentes Intraoculares , Humanos , República da Coreia/epidemiologia , Incidência , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Adulto , Lentes Intraoculares/efeitos adversos , Idoso de 80 Anos ou mais , Extração de Catarata/estatística & dados numéricos , Extração de Catarata/efeitos adversos , Adulto Jovem , Adolescente , Criança , Complicações Pós-Operatórias/epidemiologia , Migração do Implante de Lente Intraocular/epidemiologia , Migração do Implante de Lente Intraocular/cirurgia , Fatores de Risco , Pré-Escolar , Distribuição por Idade , Seguimentos , Lactente
4.
Retina ; 44(8): 1337-1343, 2024 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-39047127

RESUMO

BACKGROUND: Retrospective cohort study of 561 adult patients undergoing secondary intraocular lens (IOL) implantation by vitreoretinal surgeons at a single institution from April 2015 to December 2020. METHODS: Patient historical factors, intraoperative/postoperative complications, and outcomes of IOL type (anterior chamber IOL versus scleral sutured IOL versus scleral fixated IOL versus. sulcus) were assessed. Primary outcomes were rates of postoperative retinal tears and rhegmatogenous retinal detachment. Secondary outcomes were rates of intraoperative endolaser, intraoperative retinal tear, and further IOL surgery. RESULTS: The incidence of intraoperative retinal tears was 7.3% and not significantly different between techniques. Rates of intraoperative endolaser use were 17.5% among all techniques and not significantly different between techniques. Rates of postoperative retinal tear were low (0%-2.7%). Rates of postoperative rhegmatogenous retinal detachment were not significantly different between techniques (anterior chamber IOL 9/198 [4.5%], SFIOL 1/54 [1.9%], scleral sutured IOL 14/274 [5.1%], sulcus 2/35 [5.7%], total 26/561 [4.6%], P = 0.79). Rates of repeat IOL surgery trended higher in sulcus lenses (anterior chamber IOL 5/198 [2.5%], SFIOL 4/54 [7.4%], scleral sutured IOL 16/274 [5.8%], sulcus 5/35 [14.3%], total 30/561 [5.3%], P = 0.12). CONCLUSION: Intraoperative endolaser use and intraoperative retinal tear are not uncommon in secondary IOL surgery and underscore the importance of careful vitreoretinal management among these patients.


Assuntos
Implante de Lente Intraocular , Complicações Pós-Operatórias , Descolamento Retiniano , Acuidade Visual , Vitrectomia , Humanos , Vitrectomia/métodos , Vitrectomia/efeitos adversos , Estudos Retrospectivos , Implante de Lente Intraocular/métodos , Implante de Lente Intraocular/efeitos adversos , Feminino , Masculino , Idoso , Descolamento Retiniano/cirurgia , Complicações Pós-Operatórias/epidemiologia , Pessoa de Meia-Idade , Perfurações Retinianas/cirurgia , Seguimentos , Complicações Intraoperatórias , Incidência , Reoperação , Lentes Intraoculares/efeitos adversos
5.
Vestn Oftalmol ; 140(3): 27-33, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38962976

RESUMO

Congenital subluxation of the lens as a complication of Marfan syndrome, Weill-Marchesani syndrome, microspherophakia, etc. leads to the development of amblyopia and requires timely surgical treatment with removal of the subluxated lens and implantation of an artificial intraocular lens (IOL). IOL implantation in children with pathology of the ligamentous apparatus of the lens remains an urgent problem of ophthalmic surgery due to the lack of a consensus regarding the IOL fixation method among practitioners. PURPOSE: This study evaluated the effectiveness and safety of IOL implantation with transscleral fixation using the knotless Z-suture technique in pediatric patients with congenital lens subluxation. MATERIAL AND METHODS: The study included 24 children (36 eyes) with grade III congenital subluxation of the lens who underwent phacoaspiration of the subluxated lens with IOL implantation with transscleral fixation using the knotless Z-suture performed in the Kazakh Research Institute of Eye Diseases in Almaty in the period from 2017 to 2021. The average observation period was 31.7±11.3 months (2.0 to 4.5 years). The stability of the IOL position, the state of the intrascleral sutures, visual acuity after surgery, the presence and severity of complications in the long-term period were evaluated. RESULTS: All patients (100%) had a significant improvement in visual acuity after surgery. No intraoperative complications were registered in any of the cases. Postoperative complications were noted in 8.3% of cases (n=3). The final functional outcome of surgical treatment depended on the presence of concomitant pathology, the main cause of low vision was the development of refractive amblyopia due to refractive errors. CONCLUSIONS: The presented technique of transscleral fixation of IOL has proven to be reliable, which is especially important for pediatric patients considering their high physical activity and expected lifespan.


Assuntos
Implante de Lente Intraocular , Subluxação do Cristalino , Lentes Intraoculares , Esclera , Acuidade Visual , Humanos , Masculino , Feminino , Subluxação do Cristalino/cirurgia , Subluxação do Cristalino/etiologia , Subluxação do Cristalino/diagnóstico , Implante de Lente Intraocular/métodos , Implante de Lente Intraocular/efeitos adversos , Pré-Escolar , Lentes Intraoculares/efeitos adversos , Esclera/cirurgia , Técnicas de Sutura , Resultado do Tratamento , Criança , Complicações Pós-Operatórias/etiologia
6.
BMC Ophthalmol ; 24(1): 300, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39039537

RESUMO

BACKGROUND: The aim of this study was to analyze the causes and characteristics of IOL explantation within the first year after primary implantation. METHODS: In this retrospective, cross sectional database study, a database consisting of over 2500 IOL explants sent from 199 national and international doctors over the past 10 years was analyzed. All IOLs explanted within the first year after implantation were included in this analysis. Explants with insufficient information as well as phakic and Add-on IOLs were excluded. Main outcome measures were the reason for explantation, the time between implantation and explantation, as well as IOLs' and patients' characteristics. Additionally, the explanted IOLs were microscopically and histologically analyzed, as required. RESULTS: Of all explanted IOLs from the database, 1.9% (n = 50) were explanted within the first year after implantation. The most frequent reasons for early IOL explantation were IOL dislocation (32%), visual intolerance (26%), opacification (20%), and intraoperative complications (16%). The time between implantation and explantation was the shortest in cases with intraoperative complications (1.5 ± 3.1 days), followed by IOL dislocation (90.9 ± 103.9 days), visual intolerance (98.3 ± 86.5 days), opacifications (253.5 ± 124.0 days) and other indications (249.7 ± 124.0 days). Calcification of hydrophilic IOLs was the main type of opacification (80%). Notably, seven IOLs required immediate intraoperative exchange due to an intraoperative crack in the optic or a torn off haptic. CONCLUSION: Indications for early IOL explantation were IOL dislocation, visual intolerance, opacification, and intraoperative complications. Especially intraoperative damages to the IOL and early calcification show a potential for improvement of affected IOLs and implantation systems.


Assuntos
Bases de Dados Factuais , Remoção de Dispositivo , Lentes Intraoculares , Humanos , Estudos Retrospectivos , Estudos Transversais , Feminino , Masculino , Lentes Intraoculares/efeitos adversos , Pessoa de Meia-Idade , Idoso , Complicações Pós-Operatórias/epidemiologia , Implante de Lente Intraocular , Fatores de Tempo , Adulto , Falha de Prótese , Complicações Intraoperatórias/epidemiologia , Acuidade Visual , Idoso de 80 Anos ou mais
7.
Int Ophthalmol ; 44(1): 327, 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-38997613

RESUMO

PURPOSE: To report the long term visual outcomes and complications with use of the novel CM-T Flex scleral fixated intraocular lens (CMT-SFIOL). MATERIALS AND METHODS: 116 eyes that underwent CMT-SFIOL were reviewed and 57 eyes with CMT-SFIOL that completed a 2-year follow-up were included. Main outcome measures noted were best-corrected visual acuity (BCVA) and complications. Postoperatively, follow-ups were done at 1 week (1w), 1 month (1 m), 1 year (1y) and 2-year (2y) intervals. RESULTS: 40 (70.17%) of 57 eyes received CMT-SFIOL for surgical aphakia. Mean follow up was 39.77 ± 8.44 months. BCVA for distance & near improved from 1.26 ± 0.84 to 0.76 ± 0.77, 0.50 ± 0.72 and 0.51 ± 0.73 & 1.28 ± 0.58 to 0.98 ± 0.49, 0.92 ± 0.44 and 0.89 ± 0.40 at 1 m, 1y and 2y respectively (p < 0.001 for all). At 1w, 10 eyes (17.54%) had corneal edema (CE) and 8 eyes (14.03%) had anterior chamber (AC) reaction. Two eyes (3.50%) had IOP > 30 mm Hg and 1 eye (1.75%) had vitreous hemorrhage (VH). At 1 m, 3 eyes (5.26%) had CE and 5 eyes (8.77%) had AC reaction. Two eyes (3.50%) had IOP > 30 mm Hg and 1 eye (1.75%) had VH. Cystoid macular edema was noted in 3 eyes (5.26%). At 1y and 2y, 2 eyes (3.5%) and 1 eye (1.75%), had CE. No decentration, dislocation, haptic exposure or retinal detachment was noted. No eyes required resurgery. CONCLUSION: CM-T Flex SFIOL is an effective method to correct aphakia, with reliable and safe long-term results.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Desenho de Prótese , Esclera , Acuidade Visual , Humanos , Feminino , Masculino , Esclera/cirurgia , Lentes Intraoculares/efeitos adversos , Pessoa de Meia-Idade , Seguimentos , Estudos Retrospectivos , Idoso , Implante de Lente Intraocular/métodos , Implante de Lente Intraocular/efeitos adversos , Adulto , Complicações Pós-Operatórias/epidemiologia , Idoso de 80 Anos ou mais , Fatores de Tempo , Resultado do Tratamento , Afacia Pós-Catarata/cirurgia , Afacia Pós-Catarata/fisiopatologia
8.
Cesk Slov Oftalmol ; 80(3): 170-174, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38886109

RESUMO

The aim of the thesis is to present the case of a patient in whom bilateral calcification of the hydrophilic intraocular lens (IOL) Lentis M+ LS-313 MF30 (Oculentis) has developed. Due to the negative effect on visual functions, explantation and replacement of the artificial lens was necessary in both eyes. Case Report: An overview of the available literature summarized the diagnostics, current examination methods and possibilities of the surgical solution of calcification of the bifocal hydrophilic lens Lentis M+ LS-313 MF30 (Oculentis). The specific solution is described in a case report of a patient in whom calcification of both lenses developed 6 years after implantation of the IOL. In 2015, the patient underwent uncomplicated cataract surgery of both eyes with the implantation of an artificial intraocular lens into the capsule. In September 2021, an 82-year-old man was examined at our outpatient clinic for deterioration of visual acuity and changes in the material of the artificial IOL which were perceptible during a clinical examination, on the recommendation of a local ophthalmologist. Blurred vision predominated. A diagnosis of intraocular lens opacification was confirmed and documented using a Scheimpflug camera (OCULUS Pentacam HR) and anterior OCT (Avanti RTVue XR Optovue,). The patient was indicated for explantation and replacement of the opacified intraocular lens in the left and subsequently in the right eye- The same type of IOL was used for reimplantation with good functional results. Conclusion: Since 2010, multifocal lens implantation has been on an upward trend worldwide. This type of MF IOL has also been used in thousands of implantations. A number of other explantations can be expected in the coming years. The optimal solution is the correct replacement of the calcified IOL with the same construction made of safer hydrophobic material.


Assuntos
Melanoma , Radiocirurgia , Humanos , Masculino , Radiocirurgia/efeitos adversos , Melanoma/radioterapia , Idoso de 80 Anos ou mais , Calcinose/cirurgia , Calcinose/diagnóstico por imagem , Neoplasias da Coroide/radioterapia , Neoplasias da Coroide/diagnóstico , Lentes Intraoculares/efeitos adversos , Lesões por Radiação/etiologia , Lesões por Radiação/diagnóstico , Lesões por Radiação/cirurgia , Neoplasias Uveais/radioterapia , Implante de Lente Intraocular/efeitos adversos
9.
Acta Med Okayama ; 78(3): 295-300, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38902219

RESUMO

A Japanese woman in her 70s was referred to our hospital for the evaluation and treatment of high intraocular pressure (IOP) in her right eye. She had undergone bilateral cataract surgeries and the insertion of hydrophilic acrylic intraocular lenses (IOLs). We performed trabeculotomy and trabeculectomy to lower her right IOP; thereafter, a circular opacity was observed on the right eye's IOL surface. We removed the right IOL because that eye's vision had decreased due to IOL opacification. The analysis of the removed IOL revealed that the main opacity component was calcium phosphate. This is the first post-glaucoma-surgery IOL calcification case report.


Assuntos
Calcinose , Glaucoma , Lentes Intraoculares , Humanos , Feminino , Lentes Intraoculares/efeitos adversos , Calcinose/etiologia , Idoso , Glaucoma/cirurgia , Glaucoma/etiologia , Implante de Lente Intraocular/efeitos adversos , Complicações Pós-Operatórias/etiologia
10.
Int Ophthalmol ; 44(1): 240, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38904711

RESUMO

PURPOSE: To clarify the characteristics of intraocular lens (IOL) dislocation requiring IOL suture or intraocular scleral fixation. METHODS: This retrospective consecutive case series included 21 eyes (21 patients) who required sutured or sutureless intrascleral IOL fixation following IOL extraction owing to IOL dislocation at the outpatient clinic in the Department of Ophthalmology, Saitama Red Cross Hospital, Japan, between January and December 2019. Medical records were retrospectively reviewed for background diseases, location of the dislocated IOL (intracapsular/extracapsular), insertion of a capsular tension ring (CTR), and the period from IOL insertion to dislocation. RESULTS: We included 21 eyes of 21 patients who required IOL suture or intrascleral fixation for IOL dislocation at our clinic from January to December 2019 were included. The most common background disease was pseudoexfoliation syndrome (four cases), followed by atopic dermatitis, dysplasia/dehiscence of the zonule, post-retinal detachment surgery, high myopia, and uveitis (three cases each). At the time of dislocation, the IOLs were either intracapsular (16 cases, including 3 cases with CTR insertion) or extracapsular (5 cases). The time from IOL insertion to IOL dislocation was 13.7 ± 8.1 years (maximum: 31.3 years, minimum: 1.7 years). CONCLUSIONS: In this study, all 21 cases represented late IOL dislocations occurring after 3 months postoperatively. Among these late IOL dislocation cases, IOL dislocation occurred in a short-medium period of time, especially in those with CTR insertion and weakness/dehiscence of the zonule, with an average of 3 to 5 years postoperatively. We propose referring to these cases as intermediate-term IOL dislocation.


Assuntos
Migração do Implante de Lente Intraocular , Lentes Intraoculares , Humanos , Estudos Retrospectivos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Migração do Implante de Lente Intraocular/cirurgia , Migração do Implante de Lente Intraocular/etiologia , Migração do Implante de Lente Intraocular/diagnóstico , Lentes Intraoculares/efeitos adversos , Idoso de 80 Anos ou mais , Fatores de Tempo , Acuidade Visual , Adulto , Esclera/cirurgia , Técnicas de Sutura , Seguimentos , Implante de Lente Intraocular/métodos , Implante de Lente Intraocular/efeitos adversos , Complicações Pós-Operatórias
11.
J Fr Ophtalmol ; 47(8): 104237, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38917616

RESUMO

PURPOSE: Explore the visual outcome and complications of iris fixation intraocular lenses (IFIOL) and sutureless scleral-fixated intraocular lenses (SSFIOL) in the surgical management of patients without exchanging dislocated posterior chamber intraocular lenses (PCIOLs) in the vitreous. METHODS: Retrospectively, 14 IFIOL and 15 SSFIOL reimplantations for dislocated PCIOLs were analyzed. Mean follow-up of reIFIOL group and reSSFIOL group: 11.3±2.0 (range: 9-15) months and 11.8±2.2 (range: 9-16) months, respectively. Preoperative and postoperative outcomes, operative indications, and complications were evaluated. RESULTS: Primary surgical indications were pseudoexfoliation (PXE) (21.4%), post-cataract surgery (PCS) (35.7%), trauma (42.8%) in the reIFIOL group, and PXE (26.6%), PCS (40%) trauma (33.3%) in reSSFIOL group, respectively. At the latest follow-up, there was an improvement in best-corrected visual acuity (BCVA) (0.053±0.051 to 0.53±0.13, P<0.0001) in reIFIOL group and (0.05±0.02 to 0.64±0.16, P<0.0001) in reSSFIOL group. Postoperative complications of reIFIOL group and reSSFIOL group included corneal edema (14.2%; nil), IOP elevation (21.4%; 7.1%), bullous keratopathy (14.2%; nil), anterior uveitis (35.7%; 13.3%), cystoid macular edema (CME) (21.4%; 7.1%), pupil ovalization (21.4%; nil), broken haptic (none; 13.3%), IOL exchange (nil; 13.3%), and vitreous hemorrhage (nil; 14.2%). CONCLUSIONS: Self-dislocated IOL reimplantation may enable much earlier visual rehabilitation in the reSSFIOL group than in the reIFIOL group. Moreover, the 27G trocar-assisted reSSFIOL technique takes a shorter operation time and relatively lower complication rates. However, further prospective studies with larger series and longer follow-up periods are required.


Assuntos
Migração do Implante de Lente Intraocular , Iris , Implante de Lente Intraocular , Lentes Intraoculares , Complicações Pós-Operatórias , Esclera , Procedimentos Cirúrgicos sem Sutura , Acuidade Visual , Humanos , Esclera/cirurgia , Estudos Retrospectivos , Masculino , Feminino , Lentes Intraoculares/efeitos adversos , Iris/cirurgia , Pessoa de Meia-Idade , Implante de Lente Intraocular/métodos , Implante de Lente Intraocular/efeitos adversos , Idoso , Procedimentos Cirúrgicos sem Sutura/métodos , Resultado do Tratamento , Migração do Implante de Lente Intraocular/cirurgia , Complicações Pós-Operatórias/etiologia , Adulto , Idoso de 80 Anos ou mais , Seguimentos , Técnicas de Sutura
12.
J Fr Ophtalmol ; 47(6): 104186, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38663226

RESUMO

PURPOSE: To compare two swept-source OCT optical biometers, the Anterion® (Heidelberg Engineering GmbH, Heidelberg, Germany) and the IOLMaster 700® (Carl Zeiss Meditec AG, Jena, Germany), in the analysis of biometric data, intraocular lens (IOL) calculation and postoperative spherical equivalent predictability. METHODS: This was a real-life, single-center, retrospective study including 152 eyes of 81 consecutive patients referred for cataract surgery. All patients were examined with the IOLMaster 700® and the Anterion®. Biometric data (axial length [AL], anterior chamber depth [ACD], mean keratometry [Km], K1 [flat keratometry], K2 [steep keratometry] and axis, TK1 [flat total keratometry], TK2 [steep total keratometry], central pachymetry, lens thickness [LT], white-to-white distance [WTW]), IOL calculation with the SRK/T formula, and postoperative refractive outcome at 1 month were compared. RESULTS: All biometric measurements were significantly different between the two biometers. Correlations were excellent for AL, pachymetry, ACD, LT and keratometry measurements, and for the IOL calculation (r>0.96, intraclass correlation coefficient=1). The IOL power for emmetropia was similar between both biometers when the SRK/T formula was used (20.84±3.24D versus 20.86±3.29D, P=0.61). The mean postoperative spherical equivalent prediction error calculated using the SRK/T formula was 0.03±0.5D for the IOLMaster 700® versus 0.01±0.47D for the Anterion® (P=0.12). CONCLUSIONS: This study showed excellent correlation and agreement for the biometric measurements and the IOL power calculation with the SRK/T formula between both biometers.


Assuntos
Biometria , Extração de Catarata , Lentes Intraoculares , Refração Ocular , Tomografia de Coerência Óptica , Humanos , Biometria/instrumentação , Biometria/métodos , Estudos Retrospectivos , Masculino , Feminino , Tomografia de Coerência Óptica/métodos , Idoso , Pessoa de Meia-Idade , Refração Ocular/fisiologia , Lentes Intraoculares/efeitos adversos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Implante de Lente Intraocular/métodos
13.
Int Ophthalmol ; 44(1): 194, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656707

RESUMO

PURPOSE: To evaluate the magnitude of IOL transversal shift (ITS) after phacoemulsification and to analyse the factors contributing to IOL decentration and ITS. METHODS: 94 consecutive patients who underwent cataract surgery and IOL implantation was enrolled. Each patient underwent anterior segment optical coherence tomography with CASIA 2 (Tomey, Nagoya, Japan) to assess crystalline lens decentration, thickness and diameter seven days preoperatively and at one and sixty days postoperatively. Univariate and multivariate linear regression analysis were performed to evaluate the determinants of ITS and final decentration. RESULTS: The preoperative crystalline lens diameter was associated with the ITS and with the IOL final decentration. A positive association between the final IOL decentration and the first post-surgical day decentration was found (p < 0.0001). CONCLUSION: Greater crystalline lens diameter was associated with greater decentration and with greater ITS. Day-one IOL decentration seems to be the main determinant of final IOL decentration.


Assuntos
Segmento Anterior do Olho , Facoemulsificação , Tomografia de Coerência Óptica , Humanos , Facoemulsificação/efeitos adversos , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Idoso , Segmento Anterior do Olho/diagnóstico por imagem , Lentes Intraoculares/efeitos adversos , Pessoa de Meia-Idade , Acuidade Visual , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/etiologia , Implante de Lente Intraocular/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Cristalino/diagnóstico por imagem , Estudos Prospectivos
15.
BMC Ophthalmol ; 24(1): 141, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38549070

RESUMO

PURPOSE: In the present study, we aimed to evaluate the efficacy of the bandage contact lens (BCLs) in the treatment of dry eye disease (DED) after complicated cataract or/and intraocular lens (IOL) surgery. METHODS: In this retrospective, single-centered, observational study, we collected data from 69 patients who underwent complicated cataract or/and IOL surgery. Of these, 35 cases wore their own BCLs immediately after the operation, while the other 34 cases did not have their own BCLs and were instead covered with gauze. The Ocular Surface Disease Index (OSDI) questionnaire, slit-lamp microscope examination, keratograph analysis, and Schirmer I test were measured at baseline, 1 week and 1 month postoperatively. RESULTS: In the BCL group, the score of the OSDI questionnaire was significantly decreased at 1 week and 1 month postoperatively compared with baseline levels (P = 0.000, collectively). Moreover, the fluorescein staining score of the BCL group was remarkably decreased 1-week and 1-month postoperatively compared with the non-BCL group (P = 0.000 and P = 0.000, respectively). Furthermore, the redness score of the BCL group was also better compared with the non-BCL group at 1 week and 1 month postoperatively (P = 0.014 and P = 0.004, respectively). CONCLUSIONS: Complicated cataract or/and IOL surgery would intensify the DED. Early application of BCLs postoperatively improved patients' comfort and alleviated dry eye-related symptoms and signs. Furthermore, this mechanism might involve the acceleration of corneal epithelial healing, the alleviation of ocular stress response and the stabilization of the tear film. TRIAL REGISTRATION: Trial registration ClinicalTrials, NCT04120389. Registered 10 October 2019-retrospectively registered.


Assuntos
Catarata , Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Lentes Intraoculares , Humanos , Estudos Retrospectivos , Lentes Intraoculares/efeitos adversos , Catarata/complicações , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/diagnóstico , Lentes de Contato Hidrofílicas/efeitos adversos , Bandagens/efeitos adversos
16.
Int Ophthalmol ; 44(1): 151, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38507136

RESUMO

PURPOSE: To identify the rate and characteristics of cataract surgery candidates suitable for multifocal intraocular lens implantation among patients undergoing preoperative evaluation in a public hospital. MATERIALS AND METHODS: Screening was performed based on the patient's medical records, comprehensive ophthalmic examination, optical biometry (Zeiss, IOL Master 700) and optical coherence tomography (OCT) (Heidelberg, OCT Spectralis) in accordance with the relevant indications and contraindications mentioned in the pertinent literature. Patients were included in the present study if they were eligible for bilateral cataract surgery. The exclusion criteria were the presence of central nervous system or motility issues, prior refractive surgery, the presence of astigmatism greater than 1 dioptre and/or the presence of important ocular comorbidities in either eye. RESULTS: The study evaluated 1200 consecutive patients. Four hundred thirty-two patients (36%) were not eligible for bilateral surgery and were excluded from the study. Of the 768 patients included in the present study, 346 (45.1%) were considered suitable candidates. Four hundred twenty-two patients (54.9%) were excluded for one or both eyes. Among them, 121 (28.7%) were excluded because of retinal disease, 120 (28.4%) because of regular astigmatism (> 1.0 D of corneal astigmatism), 32 (7.5%) because of pseudoexfoliation or zonular instability, and 30 (7.1%) because of glaucoma or ocular hypertension; in addition, 90 (21.3%) patients were excluded for multiple reasons. Suitable candidates were significantly younger (70 and 75 years, respectively) (p < 0.001). After being informed about the potential risks and benefits of MOIL implantation, 212 of 346 (83.8%) eligible patients provided consent. CONCLUSION: Close to half of cataract patients in a public hospital were eligible for MOIL implantation, and the majority of patients would proceed to surgery. The most prevalent contraindication was macular disease.


Assuntos
Astigmatismo , Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular/métodos , Lentes Intraoculares/efeitos adversos , Acuidade Visual , Facoemulsificação/métodos , Catarata/complicações , Catarata/epidemiologia , Refração Ocular
17.
Int Ophthalmol ; 44(1): 152, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509438

RESUMO

PURPOSE: To evaluate and compare the clinical outcomes of three different methods of intraocular lens (IOL) implantation in the surgery of subluxated cataracts. METHODS: In this retrospective, comparative, clinical interventional study, the medical records of patients who underwent IOL implantation with sutureless 27-gauge needle-assisted transconjunctival intrascleral (Group 1), Z-suture knotless transscleral (Group 2), and Cionni capsular tension ring (Cionni-CTR) assisted (Group 3) simultaneously with subluxated cataract extraction between June 2010 and June 2022 were evaluated. Demographic characteristics, follow-up times, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical and cylindrical refractive values, and spherical equivalent (SE) values of three groups were compared. Intraoperative and postoperative complications were recorded. RESULTS: There were 20 eyes in Group 1, 35 eyes in Group 2, and 40 eyes in Group 3. In all groups, statistically significant improvement was observed in postoperative UDVA and CDVA compared to preoperative values (each p < 0.05). There was no statistical difference between the groups in postoperative UDVA and CDVA values. (p = 0.130, p = 0.167 respectively). No significant difference was observed between the groups in terms of postoperative spherical, cylindrical, and SE values (each p > 0.05). CONCLUSION: The study suggests that three different IOL implantation techniques for simultaneous IOL implantation in subluxated cataract surgery have similar effects on visual and refractive outcomes.


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Humanos , Implante de Lente Intraocular/métodos , Lentes Intraoculares/efeitos adversos , Estudos Retrospectivos , Extração de Catarata/efeitos adversos , Catarata/complicações , Suturas/efeitos adversos
18.
JAMA Ophthalmol ; 142(3): e234841, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38512158

RESUMO

This case report describes a diagnosis of dystrophic calcification of a silicone intraocular lens implant in a patient who presented with foggy vision and glare.


Assuntos
Calcinose , Coristoma , Lentes Intraoculares , Humanos , Lentes Intraoculares/efeitos adversos , Calcinose/diagnóstico por imagem , Calcinose/etiologia
19.
BMC Ophthalmol ; 24(1): 77, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38378504

RESUMO

PURPOSE: To report the refractive outcomes of long (≥25.00 mm) and short (≤22.00 mm) axial length (AL) eyes undergoing immediately sequential bilateral cataract surgery (ISBCS). METHODS: In this retrospective cohort study, patients who underwent ISBCS were identified and eyes of patients with bilateral long and short ALs were included. Pre- and postoperative biometry, autorefraction, and ocular comorbidities or complications were recorded. The primary outcome was the mean refractive prediction error. RESULTS: Thirty-seven patients (74 eyes) with long ALs and 18 patients (36 eyes) with short ALs were included. The means ± standard deviations of the ALs were 26.40 ± 1.38 mm and 21.44 ± 0.46 mm in the long and short AL groups, respectively. In long AL eyes, the mean absolute error from the biometry-predicted refraction was - 0.16 ± 0.46 D, corresponding to 74% of eyes achieving a refraction within ±0.50 D of the predicted value. In short AL eyes, the mean absolute error was - 0.63 ± 0.73 D, corresponding to 44% of eyes achieving a refraction within ±0.50 D of the predicted value. Eight (44.4%) patients with short AL eyes had a myopic deviation greater than ±0.50 D from the predicted result in both eyes. CONCLUSIONS: Compared to patients with long AL eyes, ISBCS in patients with short ALs had a wider variance in refractive outcome and a lower rate of achieving a postoperative refraction within ±0.50 D of the predicted target.


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Erros de Refração , Humanos , Acuidade Visual , Implante de Lente Intraocular/efeitos adversos , Estudos Retrospectivos , Lentes Intraoculares/efeitos adversos , Refração Ocular , Erros de Refração/etiologia , Biometria , Comprimento Axial do Olho , Catarata/complicações , Extração de Catarata/efeitos adversos
20.
Sci Rep ; 14(1): 3368, 2024 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-38336847

RESUMO

In this study, we described and discussed the late onset spontaneous posterior capsule rupture with intraocular lens (IOL) dislocation years after uncomplicated cataract surgery and implantation of hydrophobic acrylic IOLs. Eight patients presented with spontaneous posterior capsule rupture and IOL dislocation 5-20 years after uncomplicated phacoemulsification and IOL (AcrySof, Alcon, US) implantation. None of the patients had undergone posterior capsulotomy in the past. Four of the patients admitted habitual eye rubbing. An intact and well-centered continuous curvilinear capsulotomy edge was observed in all cases. IOLs were dislocated or displaced behind the anterior capsulotomy with a significant decrease in vision. A large rupture with a curled edge of the broken posterior capsule was visible. Dislocated IOLs were removed, and a three-piece IOL was inserted in the sulcus in six cases and suture fixated to the sclera in two cases. Improved vision was achieved in all cases. Although the mechanism underlying this late complication is unclear, habitual eye rubbing or IOL design may play a role. Further investigation is needed to prevent this complication in the future.


Assuntos
Extração de Catarata , Catarata , Subluxação do Cristalino , Lentes Intraoculares , Facoemulsificação , Humanos , Lentes Intraoculares/efeitos adversos , Implante de Lente Intraocular/efeitos adversos , Extração de Catarata/efeitos adversos , Facoemulsificação/efeitos adversos , Subluxação do Cristalino/complicações , Complicações Pós-Operatórias , Desenho de Prótese , Catarata/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA