Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.931
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 10577, 2024 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719920

RESUMO

Cold hypersensitivity in the hands and feet (CHHF) is a protective or predisposing factor for many diseases; however, the relationship between CHHF and erectile dysfunction (ED) remains unclear. We aimed to investigate associations between CHHF and ED among young men of Southeast Asian origin. In this cross-sectional study, sexually active Taiwanese men aged 20-40 years were enrolled via an online questionnaire comprising general demographic information, comorbidities, subjective thermal sensations of their hands and feet in the past 6 months, and their erectile function using the International Index of Erectile Function-5 (IIEF-5). Participants who reported cold sensation of hands and feet were classified to have CHHF; those with IIEF-5 score ≤ 21 were considered to have ED. Total 54.2% and 27.9% of participants had ED and CHHF, respectively. Men with CHHF were significantly younger, had lower body mass index and IIEF-5 scores (p < 0.001), and a lower prevalence of diabetes mellitus (p = 0.033) along with higher prevalence of ED, psychiatric disorders, and insomnia (p < 0.001). After adjusting for predisposing factors of ED, CHHF (odds ratio 1.410, 95% confidence interval 1.159-1.714; p = 0.001) remained an independent predictor of ED. Thus, CHHF is independently associated with ED, affecting more than a quarter of young Taiwanese men. Autonomic dysregulation and subclinical endothelial dysfunction may be common pathophysiologies of CHHF and ED.


Assuntos
Disfunção Erétil , , Mãos , Humanos , Masculino , Disfunção Erétil/epidemiologia , Disfunção Erétil/etiologia , Taiwan/epidemiologia , Adulto , Estudos Transversais , Adulto Jovem , Mãos/fisiopatologia , Pé/fisiopatologia , Síndromes Periódicas Associadas à Criopirina/epidemiologia , Síndromes Periódicas Associadas à Criopirina/complicações , Inquéritos e Questionários , Prevalência , Temperatura Baixa/efeitos adversos , Fatores de Risco
3.
Med Eng Phys ; 127: 104165, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38692768

RESUMO

Laparoscopic instrument handles design and dimensions are crucial to determine the configuration of surgeons' hand grip and, therefore, can have a deleterious effect on overall surgical efficiency and surgeons' comfort. The aim of this study is to investigate the impact of laparoscopic handle size and hand surface area on surgical task performance. A single-blind, randomized crossover trial was carried out with 29 novice medical students. Participants performed three simulated tasks in "black box" simulators using two scissor-type handles of different sizes. Surgical performance was assessed by the number of errors and time required to complete each task. Hand anthropometric data were measured using a 3D scanner. Execution time was significantly higher when cutting and suturing tasks were performed with the smaller handle. In addition, hand surface area was positively correlated with peg transfer task time when performed with the standard handle and was correlated with cutting task time in small and standard handle groups. We also found positive correlations between execution time and the number of errors executed by larger-handed participants. Our findings indicate that laparoscopic handle size and hand area influence surgical performance, highlighting the importance of considering hand anthropometry variances in surgical instrument design.


Assuntos
Estudos Cross-Over , Laparoscopia , Humanos , Masculino , Feminino , Adulto Jovem , Desenho de Equipamento , Adulto , Análise e Desempenho de Tarefas , Mãos/cirurgia
4.
Arch Dermatol Res ; 316(5): 144, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38695894

RESUMO

Hand infection is a rare complication in patients with diabetes. Its clinical outcomes depend on the severity of hand infection caused by bacteria, but the difference in bacterial species in the regional disparity is unknown. The purpose of this study was to explore the influence of tropical and nontropical regions on bacterial species and clinical outcomes for diabetic hand. A systematic literature review was conducted using PubMed, EMBASE, Web of Science, and Google Scholar. Moreover, the bacterial species and clinical outcomes were analyzed with respect to multicenter wound care in China (nontropical regions). Both mixed bacteria (31.2% vs. 16.6%, p = 0.014) and fungi (7.5% vs. 0.8%, p = 0.017) in the nontropical region were significantly more prevalent than those in the tropical region. Staphylococcus and Streptococcus spp. were dominant in gram-positive bacteria, and Klebsiella, Escherichia coli, Proteus and Pseudomonas in gram-negative bacteria occupied the next majority in the two regions. The rate of surgical treatment in the patients was 31.2% in the nontropical region, which was significantly higher than the 11.4% in the tropical region (p = 0.001). Although the overall mortality was not significantly different, there was a tendency to be increased in tropical regions (6.3%) compared with nontropical regions (0.9%). However, amputation (32.9% vs. 31.3%, p = 0.762) and disability (6.3% vs. 12.2%, p = 0.138) were not significantly different between the two regions. Similar numbers of cases were reported, and the most common bacteria were similar in tropical and nontropical regions in patients with diabetic hand. There were more species of bacteria in the nontropical region, and their distribution was basically similar, except for fungi, which had differences between the two regions. The present study also showed that surgical treatment and mortality were inversely correlated because delays in debridement and surgery can deteriorate deep infections, eventually leading to amputation and even death.


Assuntos
Clima Tropical , Humanos , Complicações do Diabetes/microbiologia , Complicações do Diabetes/epidemiologia , Infecções Bacterianas/microbiologia , Infecções Bacterianas/terapia , Infecções Bacterianas/epidemiologia , Infecções Bacterianas/mortalidade , Mãos/microbiologia , China/epidemiologia , Bactérias/isolamento & purificação , Bactérias/classificação , Resultado do Tratamento , Amputação Cirúrgica/estatística & dados numéricos
5.
Support Care Cancer ; 32(5): 304, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652168

RESUMO

PURPOSE: Chemotherapy-induced peripheral neuropathy (CIPN) commonly involves hand dexterity impairment. However, the factors affecting hand dexterity impairment are unknown and there is currently no established treatment. The purpose of the current study was to clarify factors influencing hand dexterity impairment in taxane-induced peripheral neuropathy using subjective and objective assessments. METHODS: We assessed patient characteristics, treatment-related factors, subjective symptoms of CIPN (Patient Neurotoxicity Questionnaire [PNQ]), psychological symptoms, and upper limb dysfunction (Quick Disabilities of the Arm, Shoulder and Hand [Quick DASH]). Quantitative assessments were pinch strength, sensory threshold, hand dexterity impairment, and grip force control. Multiple regression analysis was performed using hand dexterity impairment as the dependent variable and age and PNQ, Quick DASH, and control of grip force as independent variables. RESULTS: Forty-three breast cancer patients were included in the analysis. Hand dexterity impairment in taxane-induced peripheral neuropathy patients was significantly correlated with age, grip force control, and PNQ sensory scores (p < 0.008). Multiple regression analysis demonstrated that PNQ sensory scores and grip force control were significantly associated with hand dexterity impairment (p < 0.01). CONCLUSION: Subjective symptoms (numbness and pain) and grip force control contributed to impaired hand dexterity in taxane-induced peripheral neuropathy.


Assuntos
Antineoplásicos , Neoplasias da Mama , Força da Mão , Mãos , Doenças do Sistema Nervoso Periférico , Taxoides , Humanos , Feminino , Pessoa de Meia-Idade , Doenças do Sistema Nervoso Periférico/induzido quimicamente , Doenças do Sistema Nervoso Periférico/fisiopatologia , Força da Mão/fisiologia , Taxoides/efeitos adversos , Idoso , Adulto , Mãos/fisiopatologia , Neoplasias da Mama/tratamento farmacológico , Inquéritos e Questionários , Antineoplásicos/efeitos adversos , Análise de Regressão , Avaliação da Deficiência , Hidrocarbonetos Aromáticos com Pontes/efeitos adversos
6.
Sensors (Basel) ; 24(8)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38676202

RESUMO

Haptic hands and grippers, designed to enable skillful object manipulation, are pivotal for high-precision interaction with environments. These technologies are particularly vital in fields such as minimally invasive surgery, where they enhance surgical accuracy and tactile feedback: in the development of advanced prosthetic limbs, offering users improved functionality and a more natural sense of touch, and within industrial automation and manufacturing, they contribute to more efficient, safe, and flexible production processes. This paper presents the development of a two-finger robotic hand that employs simple yet precise strategies to manipulate objects without damaging or dropping them. Our innovative approach fused force-sensitive resistor (FSR) sensors with the average current of servomotors to enhance both the speed and accuracy of grasping. Therefore, we aim to create a grasping mechanism that is more dexterous than grippers and less complex than robotic hands. To achieve this goal, we designed a two-finger robotic hand with two degrees of freedom on each finger; an FSR was integrated into each fingertip to enable object categorization and the detection of the initial contact. Subsequently, servomotor currents were monitored continuously to implement impedance control and maintain the grasp of objects in a wide range of stiffness. The proposed hand categorized objects' stiffness upon initial contact and exerted accurate force by fusing FSR and the motor currents. An experimental test was conducted using a Yale-CMU-Berkeley (YCB) object set consisted of a foam ball, an empty soda can, an apple, a glass cup, a plastic cup, and a small milk packet. The robotic hand successfully picked up these objects from a table and sat them down without inflicting any damage or dropping them midway. Our results represent a significant step forward in developing haptic robotic hands with advanced object perception and manipulation capabilities.


Assuntos
Dedos , Força da Mão , Robótica , Tato , Robótica/métodos , Robótica/instrumentação , Humanos , Dedos/fisiologia , Tato/fisiologia , Força da Mão/fisiologia , Impedância Elétrica , Mãos/fisiologia , Desenho de Equipamento
7.
J Orthop Surg Res ; 19(1): 256, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649996

RESUMO

BACKGROUND: The Michigan Hand Outcomes Questionnaire (MHQ) is a self-report tool widely recognized for measuring the health status of patients with hand and wrist problems from a multidimensional perspective. The aim of this study is to translate and culturally adapt the MHQ and validate its psychometric properties of validity, reliability, and responsiveness for different hand problems in Spain. METHODS: The MHQ was translated and culturally adapted following the recommendations of the American Association of Orthopaedic Surgeons. The validation process adhered to the current Consensus-Based Standards for the Selection of Health Status Measurement Instruments (COSMIN) group and was conducted on 262 hand patients. Reliability was assessed through internal consistency using Cronbach's alpha. The study evaluated the test-retest reliability of the measurements using the intraclass correlation coefficient (ICC). Additionally, the measurement error was calculated using the standard error of measurement (SEM) and smallest detectable change (SDC). To assess the structural validity, confirmatory factor analysis (CFA) was employed, while construct validity was evaluated using Pearson's correlation coefficient. Finally, responsiveness was assessed using effect size (ES), standardized response mean (SRM), and minimum clinically important difference (MCID). RESULTS: The reliability of the test was confirmed through internal consistency analysis, with a good Crombach's Alpha (0.82-0.85), and test-retest analysis, with good values of ICC (0.74-0.91). The measurement error was also assessed, with low values of SEM (1.70-4.67) and SDC (4.71-12.94)). The CFA confirmed the unidimensionality of each scale with goodness of fit indices, while the MHQ showed a high and negative correlation with DASH (r = - 0.75, P < 0.001) and DASH-work (r = - 0.63, P < 0.001) and was irrelevant with EQ-5D (r = - 0.01, P > 0.005) and grip strength (r = 0.05, P > 0.005). At week 5, all 222 patients across the three diagnosed hand subgroups showed moderate to high values above 0.92 for ES and SRM, with one MCID above 6.85. CONCLUSIONS: The MHQ-Sp was culturally adapted, and the results of this version showed good reliability and validity as well as high responsiveness for a wide range of hand conditions after surgical or conservative treatment in Spain.


Assuntos
Psicometria , Humanos , Masculino , Feminino , Reprodutibilidade dos Testes , Espanha , Pessoa de Meia-Idade , Psicometria/métodos , Inquéritos e Questionários/normas , Adulto , Idoso , Comparação Transcultural , Traduções , Mãos
8.
BMC Infect Dis ; 24(1): 395, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609847

RESUMO

BACKGROUND: Non-tuberculous mycobacteria (NTM) are environmental organisms that are increasingly contributing to human infections. Mycobacterium immunogenum, a variant of NTM discovered in 2001, is a rapidly growing mycobacterium that exhibits multidrug resistance. Reports of infections caused by this organism, particularly tenosynovitis in the musculoskeletal system, are limited. CASE PRESENTATION: A 71-year-old female with vesicular pemphigus, undergoing immunosuppressive therapy, presented with a progressively enlarging tumour on the dorsum of her right hand, along with erythematous papules that extended across her right forearm. The specimens of skin tissues and blood cultures revealed the presence of M. immunogenum. Magnetic resonance imaging evaluation led to the diagnosis of pyogenic extensor tenosynovitis. A multidrug regimen, comprising amikacin and clarithromycin, was initiated, followed by synovectomy. The patient underwent a course of 180 days of antimicrobial therapy and demonstrated no signs of disease recurrence one year after treatment completion. CONCLUSION: Early diagnosis and surgical intervention are crucial to prevent the adverse prognostic implications of pyogenic extensor tenosynovitis caused by M. immunogenum. Effective management requires precise microbial identification and susceptibility testing, necessitating collaborative engagement with microbiological laboratories.


Assuntos
Mycobacteriaceae , Tenossinovite , Humanos , Feminino , Idoso , Tenossinovite/diagnóstico , Tenossinovite/tratamento farmacológico , Tenossinovite/cirurgia , Diagnóstico Precoce , Mãos , Micobactérias não Tuberculosas
9.
Lasers Med Sci ; 39(1): 101, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630146

RESUMO

PURPOSE: The mainstay of treatment for nonmelanoma skin cancer (NMSC) on thin skin remains surgical, but procedures on older hands may be complicated by skin fragility and dermal atrophy. Used without cooling, 595 nm (nm) pulsed dye laser (PDL) has the capability of destroying NMSC through nonspecific thermal necrosis. The purpose of this study was to understand recurrence of NMSC on dorsal hands of older patients after one or two treatments using 595 nm PDL. METHODS: A retrospective chart review identified 147 cases of NMSC located on the dorsal hands treated with 595 nm PDL. Cases of basal cell carcinomas (BCCs) and squamous cell carcinomas (SCCs) were included. All patients received one to two treatments with PDL. The primary outcome was the recurrence of carcinoma. RESULTS: Among NMSC cases treated with PDL, recurrence occurred in 12 patients (8.2%). No cases of BCC recurred during the study period. Recurrence of SCC was 4.7% for SCC in situ and 10.4% recurrence for invasive SCC (p = 0.34). Among 71 patients treated once, recurrence occurred in 10 patients (14.1%), and among 76 cases treated twice, recurrence occurred in 2 patients (2.6%, p = 0.01). CONCLUSION: Two treatments of PDL for NMSC on the dorsal hands of older patients was well tolerated, had low recurrence, and seemed more effective than one treatment.


Assuntos
Carcinoma Basocelular , Lasers de Corante , Neoplasias Cutâneas , Humanos , Lasers de Corante/uso terapêutico , Estudos Retrospectivos , Mãos , Neoplasias Cutâneas/radioterapia , Carcinoma Basocelular/radioterapia
10.
J Vis Exp ; (205)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38619242

RESUMO

Powerful genetic and molecular tools available in mouse systems neuroscience research have enabled researchers to interrogate motor system function with unprecedented precision in head-fixed mice performing a variety of tasks. The small size of the mouse makes the measurement of motor output difficult, as the traditional method of electromyographic (EMG) recording of muscle activity was designed for larger animals like cats and primates. Pending commercially available EMG electrodes for mice, the current gold-standard method for recording muscle activity in mice is to make electrode sets in-house. This article describes a refinement of established procedures for hand fabrication of an electrode set, implantation of electrodes in the same surgery as headplate implantation, fixation of a connector on the headplate, and post-operative recovery care. Following recovery, millisecond-resolution EMG recordings can be obtained during head-fixed behavior for several weeks without noticeable changes in signal quality. These recordings enable precise measurement of forelimb muscle activity alongside in vivo neural recording and/or perturbation to probe mechanisms of motor control in mice.


Assuntos
Mãos , Extremidade Superior , Animais , Camundongos , Eletrodos , Membro Anterior , Músculos
11.
Bioinspir Biomim ; 19(3)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38579732

RESUMO

In the field of robotic hands, finger force coordination is usually achieved by complex mechanical structures and control systems. This study presents the design of a novel transmission system inspired from the physiological concept of force synergies, aiming to simplify the control of multifingered robotic hands. To this end, we collected human finger force data during six isometric grasping tasks, and force synergies (i.e. the synergy weightings and the corresponding activation coefficients) were extracted from the concatenated force data to explore their potential for force modulation. We then implemented two force synergies with a cable-driven transmission mechanism consisting of two spring-loaded sliders and five V-shaped bars. Specifically, we used fixed synergy weightings to determine the stiffness of the compression springs, and the displacements of sliders were determined by time-varying activation coefficients. The derived transmission system was then used to drive a five-finger robotic hand named SYN hand. We also designed a motion encoder to selectively activate desired fingers, making it possible for two motors to empower a variety of hand postures. Experiments on the prototype demonstrate successful grasp of a wide range of objects in everyday life, and the finger force distribution of SYN hand can approximate that of human hand during six typical tasks. To our best knowledge, this study shows the first attempt to mechanically implement force synergies for finger force modulation in a robotic hand. In comparison to state-of-the-art robotic hands with similar functionality, the proposed hand can distribute humanlike force ratios on the fingers by simple position control, rather than resorting to additional force sensors or complex control strategies. The outcome of this study may provide alternatives for the design of novel anthropomorphic robotic hands, and thus show application prospects in the field of hand prostheses and exoskeletons.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Mãos/fisiologia , Dedos/fisiologia , Força da Mão
12.
Ann Plast Surg ; 92(4S Suppl 2): S132-S135, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556661

RESUMO

INTRODUCTION: Vascular malformations (VMs) typically appear at birth and grow commensurately with patients. They can vary broadly in vessel type and tissue involvement, and upper extremity (UE) VMs can pose unique functional and aesthetic challenges in children. Given the advent of operative and nonoperative technologies like sclerotherapy and medications, a contemporary review of the surgical management of UE VMs is warranted. METHODS: We performed a retrospective review of all patients who had surgical management of VMs from 2010 to 2021 at The Children's Hospital of Philadelphia. Demographics, lesion characteristics, treatment (including preceding nonsurgical therapies), complications, and final outcomes were recorded. Operative notes were reviewed for date of operation, depth of excision, type of closure, and current procedural terminology code. RESULTS: Sixty-seven patients with 88 procedures were studied. Average patient age was 5.8 years, with 64% White and 67% male. Venous (34%) and lymphatic (19%) malformations were most common, and anatomic locations were most frequently on the hand (33%) and forearm (25%). The average lesion diameter was 4.2 cm, although this varied by location (eg, 2.9 cm, hand; 11.1 cm, chest wall). Fifty-eight patients (87%) underwent surgical excision as their index procedure, and 9 had sclerotherapy before surgery. Thirty-nine patients (60%) had subcutaneous excisions, and the remainder required subfascial or intramuscular excisions. Nearly all excisions were closed primarily (97%). Of the 53 patients with documented follow-up, 32 patients (60%) had complete resolution of their lesion as of their final visit. Thirty of these 32 patients with no clinical evidence of residual VM had only 1 surgery for excision. CONCLUSION: Upper extremity VMs were composed of diverse conditions with varying vessel types, size, depth, and anatomic sites. Surgical excision of VMs of the UE was safe and effective. A majority of VMs were fully excised after 1 procedure and frequently closed primarily with relatively low complication rates. Future work should investigate decision-making and outcomes of all treatment options of VMs of the UE for optimal functionality and aesthetics.


Assuntos
Malformações Vasculares , Veias , Criança , Recém-Nascido , Humanos , Masculino , Pré-Escolar , Feminino , Estudos Retrospectivos , Veias/cirurgia , Malformações Vasculares/cirurgia , Escleroterapia/métodos , Mãos , Resultado do Tratamento
13.
Artigo em Chinês | MEDLINE | ID: mdl-38664031

RESUMO

Objective: To explore the clinical effects of early rehabilitation treatment after repair surgery of skin and soft tissue defects accompanied by extensor tendon injury on the back of hand. Methods: This study was a retrospective non-randomized controlled study. From February 2015 to February 2023, 24 patients (15 males and 9 females, aged 12-55 years) with skin and soft tissue defects accompanied by extensor tendon injury on the back of hand, who met the inclusion criteria and were repaired with flap transplantation and tendon grafting or tendon anastomosis, were admitted to the First Affiliated Hospital of Air Force Medical University. According to different intervention time for postoperative rehabilitation treatment of patients, the patients were divided into conventional rehabilitation group and early rehabilitation group, with 12 cases in each group. Patients in early rehabilitation group received rehabilitation treatment immediately after surgery under the rehabilitation guidance of specialized rehabilitation physicians based on the characteristics of different postoperative periods. Patients in conventional rehabilitation group began rehabilitation treatment from the third week after surgery, and their rehabilitation treatment was the same as that of patients in early rehabilitation group from the second week after surgery. The patients in 2 groups were treated in the hospital until the sixth week after surgery. The occurrence of flap vascular crisis and tendon rupture were observed within 6 weeks after surgery. After 6 weeks of surgery, the manual muscle test was used to measure the pinching force between the index finger and thumb, lateral pinching force, three-point pinching force, and grip force of the affected hand; the total action motion method was used to evaluate the finger joint range of motion of the affected hand, and the excellent and good ratio was calculated; the Carroll upper extremity function test was used to score and rate the function of the affected hand. Results: Within 6 weeks after surgery, only 1 patient in conventional rehabilitation group suffered from venous crisis, and the flap survived after the second surgical exploration and anastomosis of blood vessels; there was no occurrence of tendon rupture in patients of 2 groups. After 6 weeks of surgery, there were no statistically significant differences in pinching force between the index finger and thumb, lateral pinching force, three-point pinching force, or grip force of the affected hand between the two groups of patients (P>0.05); the excellent and good ratio of the finger joint range of motion of the affected hand of patients in early rehabilitation group was 11/12, which was higher than 7/12 in conventional rehabilitation group, but there was no statistically significant difference (P>0.05); the affected hand function score of patients in early rehabilitation group was 90±6, which was significantly higher than 83±8 in conventional rehabilitation group (t=2.41, P<0.05); the function rating of the affected hand of patients in early rehabilitation group was obviously better than that in conventional rehabilitation group (Z=2.04, P<0.05). Conclusions: Early rehabilitation treatment for patients with skin and soft tissue defects accompanied by extensor tendon injury on the back of hand after repair surgery can improve hand function, but it would not increase surgery related complications, which is worthy of clinical promotion and application.


Assuntos
Lesões dos Tecidos Moles , Retalhos Cirúrgicos , Traumatismos dos Tendões , Humanos , Masculino , Feminino , Adulto , Estudos Retrospectivos , Traumatismos dos Tendões/reabilitação , Traumatismos dos Tendões/cirurgia , Pessoa de Meia-Idade , Lesões dos Tecidos Moles/cirurgia , Lesões dos Tecidos Moles/reabilitação , Retalhos Cirúrgicos/cirurgia , Adolescente , Traumatismos da Mão/cirurgia , Traumatismos da Mão/reabilitação , Adulto Jovem , Mãos/cirurgia , Criança , Pele/lesões , Tendões/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Transplante de Pele/métodos
15.
Dermatol Surg ; 50(5): 467-470, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38460193

RESUMO

BACKGROUND: Improving the appearance of lentigines on the hands is a key component to hand rejuvenation. Soft tissue fillers revolumize hands, but do not address pigmentary changes. OBJECTIVE: This study investigated the effiacy of a 15% trichloroacetic acid (TCA) + 3% glycolic acid (GA) combination peel in improvement of appearance of hand lentigines. METHODS: A prospective evaluator-blinded, split-hand study was performed using a 15% TCA + 3% GA peel to treat patients with hand lentigines. Subjects received a total of 3 treatments at 4-week intervals on 1 hand, with the other hand serving as an untreated control. Final photographs were taken 12 weeks after the last treatment. Two blinded board-certified dermatologists graded improvement in hand lentigines using a 5-point scale. RESULTS: Eighteen of 20 patients completed the study (90%). The mean age was 64.4 years (SE 1.6, range 51-71). The mean pain scores were 3.8 (SE 0.4) on a 10-point scale (1 = no pain, 10 = extremely painful). Blinded evaluators correctly identified the after-treatment photographs in 16 patients (88%). Physician and patient-graded mean improvement of lentigines was significant for treated versus control hands ( p < .01). No adverse events were noted. CONCLUSION: A series of three 15% TCA + 3% GA peels are effective and safe in the treatment of hand lentigines.


Assuntos
Abrasão Química , Glicolatos , Ácido Tricloroacético , Humanos , Ácido Tricloroacético/administração & dosagem , Ácido Tricloroacético/efeitos adversos , Glicolatos/administração & dosagem , Pessoa de Meia-Idade , Abrasão Química/métodos , Estudos Prospectivos , Idoso , Feminino , Masculino , Lentigo/tratamento farmacológico , Método Simples-Cego , Mãos , Ceratolíticos/administração & dosagem , Resultado do Tratamento
16.
J Hand Surg Eur Vol ; 49(5): 649-653, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38488627

RESUMO

Identifying a good research question is one of the most important steps when laying the foundation of a research project. A good research question can aim to answer a hotly debated clinical issue, challenge a pre-existing dogma or make a contribution to specific aspects of a broader field of study. The difficulty in defining the question lies with pinpointing an important research topic or an area that is characterized by a lack of knowledge (the What), grasping the significance of how a precisely defined study can potentially impact on clinical practices (the Why) and determining the optimal study design tailored to answer the specific question (the How). These three domains constitute pivotal concepts in the process of shaping the research question.


Assuntos
Mãos , Projetos de Pesquisa , Humanos , Mãos/cirurgia , Pesquisa Biomédica
17.
Ned Tijdschr Geneeskd ; 1682024 03 06.
Artigo em Holandês | MEDLINE | ID: mdl-38512277

RESUMO

A 79-year-old man visits his general practitioner due to white spots on his hands and feet. Upon examination, numerous white papules are observed, leading to a diagnosis of stucco keratosis. Stucco keratosis is typically asymptomatic and is identified by benign keratotic papules. Treatment is challenging because of the large quantities.


Assuntos
Clínicos Gerais , Ceratose , Masculino , Humanos , Idoso , , Mãos
18.
Int J Med Robot ; 20(1): e2608, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38536715

RESUMO

Sinaflex robotic telesurgery system has been introduced recently to provide ergonomic postures for the surgeon along with dexterous workspace for robotic telesurgery. The robot is described, and the forward and inverse kinematics are derived and validated by an experiment. The robot and operational workspaces and their dexterity are investigated and compared using the data collected during a dog vasectomy robotic telesurgery by Sinaflex. According to the simulation results, the workspace of the end effector is as large as 914.56 × 105 mm3, which can completely cover the ergonomic human hand workspace. The dexterity of the robot for the total and operational workspace is 0.4557 and 0.6565, respectively. In terms of the workspace size and the amount of dexterity, Sinaflex master robot can be considered a good choice to fulfil the requirements of the surgeon side robot in robotic telesurgery systems.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgiões , Cirurgia Assistida por Computador , Humanos , Animais , Cães , Cirurgia Assistida por Computador/métodos , Mãos
19.
Int J Med Robot ; 20(1): e2617, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38536731

RESUMO

BACKGROUND: Controlling a multi-grasp prosthetic hand still remains a challenge. This study explores the influence of merging gaze movements and augmented reality in bionics on improving prosthetic hand control. METHODS: A control system based on gaze movements, augmented reality, and myoelectric signals (i-MYO) was proposed. In the i-MYO, the GazeButton was introduced into the controller to detect the grasp-type intention from the eye-tracking signals, and the proportional velocity scheme based on the i-MYO was used to control hand movement. RESULTS: The able-bodied subjects with no prior training successfully transferred objects in 91.6% of the cases and switched the optimal grasp types in 97.5%. The patient could successfully trigger the EMG to control the hand holding the objects in 98.7% of trials in around 3.2 s and spend around 1.3 s switching the optimal grasp types in 99.2% of trials. CONCLUSIONS: Merging gaze movements and augmented reality in bionics can widen the control bandwidth of prosthetic hand. With the help of i-MYO, the subjects can control a prosthetic hand using six grasp types if they can manipulate two muscle signals and gaze movement.


Assuntos
Membros Artificiais , Realidade Aumentada , Humanos , Eletromiografia , Desenho de Prótese , Mãos/fisiologia , Movimento , Força da Mão/fisiologia
20.
Hand Clin ; 40(2): 189-198, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38553090

RESUMO

The profunda artery perforator (PAP) flap provides a good option for hand and upper extremity reconstruction. The reliable quality, caliber, and number of perforators in the posteromedial thigh support large flaps with long pedicles. The PAP flap has been widely used for breast reconstruction, although its use in the extremities has been slower to catch on due to the bulk and thickness of the subcutaneous tissue. The authors discuss evolution of thin flaps and our application of the thin and superthin PAP flap for upper extremity reconstruction.


Assuntos
Mamoplastia , Retalho Perfurante , Humanos , Retalho Perfurante/irrigação sanguínea , Artérias/cirurgia , Extremidade Superior/cirurgia , Mãos/cirurgia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA