Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.902
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Port J Card Thorac Vasc Surg ; 31(1): 57-58, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38743518

RESUMO

Surgical resection remains the optimal therapeutic option for early-stage operable NSCLC. Despite significant advances in recent years related to anesthetic and surgical techniques, cardiopulmonary complications remain major causes for postoperative morbimortality. In this paper we present a case of a patient who developed complete AV block followed by asystole after lung resection surgery. The patient underwent surgery via right VATS and the procedure was uneventful.  On the first post-operative day patient developed a third-degree atrioventricular block followed by 6 seconds asystole. Pharmacological treatment was instituted and implementation of a permanent pacemaker occurred on the third post-operative day, without complications. The remaining postoperative course was uneventful and the patient was discharged home on the sixth post-operative day. It is the objective of the authors to report and highlight this rare and potencial fatal complication of lung resection.


Assuntos
Bloqueio Atrioventricular , Parada Cardíaca , Neoplasias Pulmonares , Pneumonectomia , Humanos , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/diagnóstico , Parada Cardíaca/etiologia , Neoplasias Pulmonares/cirurgia , Pneumonectomia/efeitos adversos , Masculino , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Marca-Passo Artificial/efeitos adversos , Idoso , Cirurgia Torácica Vídeoassistida/efeitos adversos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia
2.
Card Electrophysiol Clin ; 16(2): 117-124, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749629

RESUMO

Transvenous laser lead extraction poses a risk of major complications (0.19%-1.8%), notably injury to the superior vena cava (SVC) in 0.19% to 0.96% of cases. Various factors contribute to SVC injury, which can be categorized as patient-related (such as female gender, low body mass index, diabetes, renal problems, anemia, and reduced ejection fraction), device-related (including the number, dwell time, and type of leads), or procedural-related (such as reason for extraction, venous obstructions, and bilateral lead placements).


Assuntos
Remoção de Dispositivo , Terapia a Laser , Veia Cava Superior , Humanos , Veia Cava Superior/lesões , Veia Cava Superior/cirurgia , Feminino , Remoção de Dispositivo/efeitos adversos , Masculino , Terapia a Laser/efeitos adversos , Pessoa de Meia-Idade , Idoso , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos
3.
Card Electrophysiol Clin ; 16(2): 157-161, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749635

RESUMO

Cardiac implantable electronic device leads can contribute to tricuspid regurgitation and also complicate surgical and transcatheter interventions to manage tricuspid regurgitation. Here we present a case of a patient with sinus node dysfunction and complete heart block who underwent extraction of a right ventricular pacing lead before tricuspid valve surgery. We review the data regarding the contribution of leads to tricuspid regurgitation and the benefits of lead extraction, risks of jailing leads during tricuspid interventions, and pacing considerations around tricuspid valve procedures.


Assuntos
Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Marca-Passo Artificial/efeitos adversos , Masculino , Idoso , Bloqueio Cardíaco/terapia , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Feminino
4.
Int Breastfeed J ; 19(1): 27, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641819

RESUMO

BACKGROUND: Lactational mastitis is a common painful and debilitating inflammation of breast tissue, generally treated conservatively or with pus puncture in case of breast abscess. However, treating mastitis in patients with implantable surgical material located in the affected breast region can be extremely challenging. We present an unusual case of lactational mastitis complicated by pacemaker pocket infection in a breastfeeding mother. CASE PRESENTATION: A 35-year-old pacemaker-dependent female developed lactational mastitis seven weeks postpartum. Initially, the condition was treated conservatively with analgesics and antibiotics. After abscess formation, pus was aspirated using fine-needle aspiration technique. Four weeks after mastitis resolution, pacemaker pocket infection developed. According to current cardiovascular implantable electronic device infection treatment guidelines a complete surgical extraction of the entire electronic system, followed by targeted antibiotic treatment and reimplantation of a new device after infection resolution, was recommended. However, after thorough discussion with the young woman and her family and after detailed review of surgery-related risks, she declined a potentially high-risk surgical procedure. Thus, only the pulse generator was explanted; pacing leads positioned in the sub-pectoral pocket; new pacemaker implanted on the contralateral side and broad-spectrum antibiotic therapy continued for six weeks. After breastfeeding cessation, and with chronic fistula development at the primary pacemaker implantation site, the possibility of delayed surgical intervention including complete extraction of retained pacemaker leads was again thoroughly discussed with her. After thoughtful consideration the woman consented to the proposed treatment strategy. A surgical procedure including transvenous lead extraction through the primary implantation venous entry site, using hand-powered bidirectional rotational sheaths, was successfully performed, removing all retained leads through the left subclavian venous entry site, and leaving the fully functional and clinically uninfected pacemaker on the contralateral site intact. CONCLUSION: Although patients' decisions for delayed extraction in a case of cardiovascular implantable electronic device infection should be discouraged by attending physicians and members of interdisciplinary teams, our case shows that a stepwise treatment strategy may be successful as a bailout clinical scenario in patients with specific requests, demands and / or clinical needs.


Assuntos
Mastite , Marca-Passo Artificial , Humanos , Feminino , Adulto , Aleitamento Materno , Abscesso/tratamento farmacológico , Mastite/terapia , Marca-Passo Artificial/efeitos adversos , Lactação , Antibacterianos/uso terapêutico
5.
J Am Coll Cardiol ; 83(17): 1656-1668, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38658105

RESUMO

BACKGROUND: Tricuspid valve annuloplasty (TA) during mitral valve repair (MVr) is associated with increased risk of permanent pacemaker (PPM) implantation, but the magnitude of risk and long-term clinical consequences have not been firmly established. OBJECTIVES: This study assesses the incidence rates of PPM implantation after isolated MVr and following MVr with TA as well as the associated long-term clinical consequences of PPM implantation. METHODS: State-mandated hospital discharge databases of New York and California were queried for patients undergoing MVr (isolated or with concomitant TA) between 2004 and 2019. Patients were stratified by whether or not they received a PPM within 90 days of index surgery. After weighting by propensity score, survival, heart failure hospitalizations (HFHs), endocarditis, stroke, and reoperation were compared between patients with or without PPM. RESULTS: A total of 32,736 patients underwent isolated MVr (n = 28,003) or MVr + TA (n = 4,733). Annual MVr + TA volumes increased throughout the study period (P < 0.001, trend), and PPM rates decreased (P < 0.001, trend). The incidence of PPM implantation <90 days after surgery was 7.7% for MVr and 14.0% for MVr + TA. In 90-day conditional landmark-weighted analyses, PPMs were associated with reduced long-term survival among MVr (HR: 1.96; 95% CI: 1.75-2.19; P < 0.001) and MVr + TA recipients (HR: 1.65; 95% CI: 1.28-2.14; P < 0.001). In both surgical groups, PPMs were also associated with an increased risk of HFH (HR: 1.56; 95% CI: 1.27-1.90; P < 0.001) and endocarditis (HR: 1.95; 95% CI: 1.52-2.51; P < 0.001), but not with stroke or reoperation. CONCLUSIONS: Compared to isolated MVr, adding TA to MVr was associated with a higher risk of 90-day PPM implantation. In both surgical groups, PPM implantation was associated with an increase in mortality, HFH, and endocarditis.


Assuntos
Marca-Passo Artificial , Valva Tricúspide , Humanos , Feminino , Masculino , Idoso , Marca-Passo Artificial/efeitos adversos , Valva Tricúspide/cirurgia , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Estudos Retrospectivos , Anuloplastia da Valva Cardíaca/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
7.
Acta Biomater ; 178: 330-339, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38432350

RESUMO

Cardiac pacing with temporary epicardial pacing wires (TEPW) is used to treat rhythm disturbances after cardiac surgery. Occasionally, TEPW cannot be mechanically extracted and remain in the thorax, where they may rarely cause serious complications like migration and infection. We aim to develop bioresorbable TEPW that will dissolve over time even if postoperative removal is unsuccessful. In the present study, we demonstrate a completely bioresorbable design using molybdenum (Mo) as electric conductor and the resorbable polymers poly(D, L-lactic-co-glycolic acid) (PLGA) and polycaprolactone (PCL) for electrically insulating double-coating. We compared the pacing properties of these Mo TEPW demonstrators to conventional steel TEPW in Langendorff-perfused rat hearts and observed similar functionality. In vitro, static immersion tests in simulated body fluid for up to 28 days elucidated the degradation behaviour of uncoated Mo strands and the influence of polymer coating thereon. Degradation was considerably reduced in double-coated Mo TEPW compared to the uncoated and the PLGA-coated condition. Furthermore, we confirmed good biocompatibility of Mo degradation products in the form of low cytotoxicity in cell cultures of human cardiomyocytes and cardiac fibroblasts. STATEMENT OF SIGNIFICANCE: Temporary pacing wires are routinely implanted on the heart surface to treat rhythm disturbances in the days following cardiac surgery. Subsequently, these wires are to be removed. When removal attempts are unsuccessful, wires are cut at skin level and the remainders are left inside the chest. Retained fragments may migrate within the body or become a centre of infection. These complications may be prevented using resorbable pacing wires. We manufactured completely resorbable temporary pacing wires using molybdenum as electrical conductor and assessed their function, degradation and biological compatibility. Our study represents an important step in the development of a safer approach to the treatment of rhythm disturbances after cardiac surgery.


Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial , Humanos , Animais , Ratos , Molibdênio/farmacologia , Implantes Absorvíveis , Pericárdio
8.
J Cardiovasc Electrophysiol ; 35(5): 1017-1025, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501386

RESUMO

Tricuspid regurgitation (TR) secondary to cardiac implantable electronic devices (CIEDs) has been well documented and is associated with worse cardiovascular outcomes. A variety of mechanisms have been proposed including lead-induced mechanical disruption of the tricuspid valvular or subvalvular apparatus and pacing-induced electrical dyssynchrony. Patient characteristics such as age, sex, baseline atrial fibrillation, and pre-existing TR have not been consistent predictors of CIED-induced TR. While two-dimensional echocardiography is helpful in assessing the severity of TR, three-dimensional echocardiography has significantly improved accuracy in identifying the etiology of TR and whether lead position contributes to TR. Three-dimensional echocardiography may therefore play a future role in optimizing lead positioning during implant to reduce the risk of CIED-induced TR. Optimal lead management strategies in addition to percutaneous interventions and surgery in alleviating TR are very important.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Valva Tricúspide/fisiopatologia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Fatores de Risco , Resultado do Tratamento , Ecocardiografia Tridimensional
9.
Radiography (Lond) ; 30(3): 770-775, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38460224

RESUMO

INTRODUCTION: Implanted pacemakers (PM) would decrease the detection of lung nodules in chest computed tomography (CT) due to the metal artifact. This study aimed to explore the computer-aided diagnosis (CAD) detectability of pulmonary nodules for the patients implanted with PMs in low- and ultra-low-dose chest CT screening. METHODS: Four different sizes of artificial nodules were placed in an anthropomorphic chest phantom with two alternative diameters utilized. A commercially available PM was placed on the surface of the left chest wall of the phantom. The image acquisitions were performed with 120 kV and 150 kV with a dedicated selective photon shield made of tin filter (Sn150 kV) at low- and ultra-low- radiation doses (1.0 and 0.5 mGy of volume CT dose index), and reconstructed with and without Iterative Metal Artifact Reduction (iMAR, Siemens Healthineers, Erlangen, Germany). The relative artifact index (AIr) was calculated as an index of metal artifacts, and the nodule detectability was evaluated with a CAD system. RESULTS: Sn150 kV reduced AIr in all acquisitions when comparing 120 kV and Sn150 kV. Although PM reduced the detectability of nodules, Sn150 kV showed higher detectability compared to 120 kV. The use of iMAR showed inconsistent results in nodule detectability. CONCLUSION: Sn150 kV reduced PM-induced metal artifacts and improved nodule detectability with CAD compared to 120 kV acquisition in many conditions including low and ultra-low doses and large phantoms, but iMAR did not improve the detectability. IMPLICATIONS FOR PRACTICE: Based on the results of the current phantom study, low and ultra-low dose with Sn150 kV acquisition reduced PM-induced metal artifacts and improved nodule detectability.


Assuntos
Artefatos , Marca-Passo Artificial , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Radiografia Torácica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
10.
Intern Med ; 63(10): 1395-1398, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38432984

RESUMO

A 74-year-old woman presented to our hospital with syncope after a coronavirus disease 2019 (COVID-19) infection. Upon admission, she passed out, and an 8 second sinus arrest was detected during telemetry monitoring. During the next syncope episode, telemetry monitoring showed that her heart rate decreased from 80 to 36 bpm, accompanied by a 2.4 second pause. A permanent pacemaker was implanted; however, the patient still experienced syncope. The head-up tilt test revealed a vasodepressor reflex syncope. The need for permanent pacemakers in patients with syncope following COVID-19 therefore remains controversial.


Assuntos
COVID-19 , Marca-Passo Artificial , Síncope , Humanos , COVID-19/complicações , Idoso , Feminino , Síncope/etiologia , Síncope/diagnóstico , SARS-CoV-2 , Teste da Mesa Inclinada , Telemetria , Síncope Vasovagal/etiologia , Síncope Vasovagal/diagnóstico
11.
Pediatr Cardiol ; 45(4): 759-769, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38427091

RESUMO

Postoperative atrioventricular block may occur after pediatric cardiac surgery. A small proportion of those who develop atrioventricular block will require pacemaker placement. The primary aim of this study was to determine factors associated with postoperative atrioventricular block. Secondary aims included determining factors associated with pacemaker placement in those with atrioventricular block. Data from the PHIS data were utilized to identify patients under 18 years of age who underwent cardiac surgery. Those who did and did not develop atrioventricular block. Univariable analyses and regression analyses were conducted to determine factors associated with postoperative atrioventricular block. Similar analyses were conducted to determine factors associated with pacemaker placement in those with atrioventricular block. A total of 43,716 admissions were identified. Of these, 2093 (5%) developed atrioventricular block and 480 (1% of total admissions) underwent pacemaker placement. Approximately 70% of those with atrioventricular block received steroids but this was not associated with a decrease in pacemaker placement. Risk factors (congenital malformations of the heart, comorbidities, medications) associated with increased risk of atrioventricular block and pacemaker placement were identified. Postoperative atrioventricular block occurred in 5% of pediatric admissions for cardiac surgery. Of these admissions with postoperative atrioventricular block, 23% required pacemaker placement. Isoproterenol and steroids were not associated with a reduction in the likelihood of pacemaker placement.


Assuntos
Bloqueio Atrioventricular , Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Marca-Passo Artificial , Criança , Humanos , Adolescente , Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/terapia , Marca-Passo Artificial/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cardiopatias Congênitas/complicações , Complicações Pós-Operatórias/etiologia , Esteroides
12.
J Cardiothorac Surg ; 19(1): 115, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38468357

RESUMO

Temporary pacing wires are often used following cardiac surgery to optimise the heart rhythm. Although setting and checking temporary pacemakers is typically undertaken by anaesthetists, intensivists, and nursing staff who care for post-cardiac surgical patients, almost all patients with temporary pacing wires are transferred to the ward with the pacing wires left in situ, where surgical, often junior, staff become responsible for temporary pacing wire management. Thus, knowledge is required not only of temporary pacing wire indications, types, and positioning at surgery, but also of practical skills in performing a pacing check, setting the pacemaker, and troubleshooting common problems. The available literature targets clinicians well-versed in temporary pacing wire management. However, this paper provides a practical 'how to' for surgical staff managing temporary pacing wires in a non-critical care environment.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Marca-Passo Artificial , Humanos , Estimulação Cardíaca Artificial , Coração , Fatores de Tempo
13.
Pacing Clin Electrophysiol ; 47(4): 577-582, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38319639

RESUMO

BACKGROUND: The real-world data on the safety profile of transvenous lead extraction (TLE) for infected cardiac implantable electronic devices (CIED) among elderly patients is not well-established. This study aimed to evaluate the hospital outcomes between patients of different age groups who underwent TLE for infected CIED. METHOD: Using the Nationwide Readmissions Database, our study included patients aged ≥18 years who underwent TLE for infected CIED between 2017 and 2020. We divided the patients into four groups: Group A. Young (<50 years), Group B. Young intermediate (50-69 years old), Group C. Older intermediate (70-79 years old), and Group D. Octogenarian (≥80 years old). We then analyzed the in-hospital outcome and 30-day readmission between these age groups. RESULTS: A total of 10,928 patients who were admitted for TLE of infected CIED were included in this study: 982 (9.0%) patients in group A, 4,234 (38.7%) patients in group B, 3,204 (29.3%) patients in group C and 2,508 (23.0%) of patients in group D. Our study demonstrated that the risk of early mortality increased with older age (Group B vs. Group A: OR: 1.92, 95% CI: 1.19-3.09, p < .01; Group C vs. Group A: OR: 2.47, 95% CI: 1.51-4.04, p < .01; Group D vs. Group A: OR: 2.82, 95% CI: 1.69-4.72, p < .01). The risk of non-home discharge also increased in elderly groups (Group B vs. Group A: OR: 1.89; 95% CI: 1.52-2.36; p < .01; Group C vs. Group A: OR: 2.82; 95% CI 2.24-3.56; p < .01; Group D vs. Group A: OR: 4.16; 95% CI: 3.28-5.28; p < .01). There was no significant difference in hospitalization length and 30-day readmission between different age groups. Apart from a higher rate of open heart surgery in group A, the procedural complications were comparable between these age groups. CONCLUSION: Elderly patients had worse in-hospital outcomes in early mortality and non-home discharge following the TLE for infected CIED. There was no significant difference between elderly and non-elderly groups in prolonged hospital stay and 30-day readmission. Elderly patients did not have a higher risk of procedural complications.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Humanos , Adolescente , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Fatores de Risco , Hospitais , Resultado do Tratamento , Estudos Retrospectivos
14.
J Cardiovasc Electrophysiol ; 35(4): 747-761, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38361241

RESUMO

INTRODUCTION: The implantation of a cardiac implantable electronic device (CIED) can have esthetic and psychological consequences on patients. We explore a heart team model for care coordination and discuss esthetic approaches for improved cosmetic outcomes in patients undergoing (CIED)-related procedures or de novo implantation. METHODS: Patients undergoing CIED surgery for approved indications between June 2015 and June 2022 were identified. Patients were included when surgical care was provided by a collaborative relationship between the primary electrophysiologist and the plastic surgeon. Patient demographics, details of the surgical procedure, information on breast implants, complications, and outcomes related to cosmesis were recorded. RESULTS: Twenty-two female patients were included in this study. The mean age was 50.2 ± 18.2 years. The mean follow-up duration was 2.2 ± 5.5 months. The top two indications for the procedure included CIED generator change (n = 9, 41%) and implantable cardioverter-defibrillator (ICD) implantation (n = 7, 32%). The most common reasons for involving plastic surgery in the procedure included surgery near breast implants (n = 10, 45%) and device displacement or discomfort (n = 8, 36%). CIED pocket position was prepectoral in 10 cases (45%), subpectoral in 11 patients (50%), and intramuscular in one patient (4.5%). The majority of the patients (20, 91%) had cosmetically acceptable results postprocedure. One patient (4.5%) had breast asymmetry on the CIED side, and another continued to have skin erosion over the CIED and leads. CONCLUSION: A heart team approach incorporating the expertize of cardiac electrophysiology and plastic surgery is essential for providing optimal care for patients with breast implants and patients requesting esthetic appeal.


Assuntos
Implantes de Mama , Procedimentos Cirúrgicos Cardíacos , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Marca-Passo Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Implantes de Mama/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos Retrospectivos
15.
Nature ; 626(8001): 990-998, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38383782

RESUMO

Electrode-based electrical stimulation underpins several clinical bioelectronic devices, including deep-brain stimulators1,2 and cardiac pacemakers3. However, leadless multisite stimulation is constrained by the technical difficulties and spatial-access limitations of electrode arrays. Optogenetics offers optically controlled random access with high spatiotemporal capabilities, but clinical translation poses challenges4-6. Here we show tunable spatiotemporal photostimulation of cardiac systems using a non-genetic platform based on semiconductor-enabled biomodulation interfaces. Through spatiotemporal profiling of photoelectrochemical currents, we assess the magnitude, precision, accuracy and resolution of photostimulation in four leadless silicon-based monolithic photoelectrochemical devices. We demonstrate the optoelectronic capabilities of the devices through optical overdrive pacing of cultured cardiomyocytes (CMs) targeting several regions and spatial extents, isolated rat hearts in a Langendorff apparatus, in vivo rat hearts in an ischaemia model and an in vivo mouse heart model with transthoracic optical pacing. We also perform the first, to our knowledge, optical override pacing and multisite pacing of a pig heart in vivo. Our systems are readily adaptable for minimally invasive clinical procedures using our custom endoscopic delivery device, with which we demonstrate closed-thoracic operations and endoscopic optical stimulation. Our results indicate the clinical potential of the leadless, lightweight and multisite photostimulation platform as a pacemaker in cardiac resynchronization therapy (CRT), in which lead-placement complications are common.


Assuntos
Terapia de Ressincronização Cardíaca , Desenho de Equipamento , Marca-Passo Artificial , Silício , Animais , Camundongos , Ratos , Terapia de Ressincronização Cardíaca/métodos , Endoscopia , Coração , Procedimentos Cirúrgicos Minimamente Invasivos , Isquemia Miocárdica/cirurgia , Isquemia Miocárdica/terapia , Miócitos Cardíacos , Semicondutores , Suínos , Modelos Animais
16.
Arch Orthop Trauma Surg ; 144(5): 2229-2238, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38421413

RESUMO

BACKGROUND: Comorbid cardiovascular diseases have been associated with poor outcomes in total knee arthroplasty (TKA); however, our understanding of TKA with prior cardiac treatment procedures has largely been undocumented. In this study, we examined TKA patients who had undergone different cardiac interventions that addressed their condition. The purpose was to characterize and compare outcomes for a growing patient population not yet analyzed. MATERIALS AND METHODS: The 2016-2019 Nationwide Inpatient Sample database was queried for 558,256 patients who had TKA (ICD-10CM). Backgrounds significant for pacemaker [PM] (n = 8025), coronary artery bypass [CABG] (n = 12,683), heart valve surgery [HV] (n = 4125), or coronary stent [CS] (n = 19,483) were compared against those without, across demographics, admission information, and various complications. RESULTS: Cardiac interventions were associated with increased age, male gender, length of stay, and cost of care. CABG, and Stent groups had more diabetics, but HV had significantly fewer (p = 0.008). PM and HV had significantly less tobacco use and, in addition to CABG, less obesity. Postoperatively, mortality was elevated in the PM [Odds ratio (OR) 2.89, p = 0.008], CABG (OR 2.53, p = 0.006) and CS group (OR 1.94, p = 0.018), but not HV. Myocardial infarctions were elevated in the CABG (OR 3.874) and CS group (OR 5.11) (p < 0.001). PM, HV, and CS had increased odds of periprosthetic fracture by 2.15-fold (p < 0.001), 2.09-fold (p < 0.001), 1.29-fold (p = 0.011) respectively. HV saw increased periprosthetic mechanical complications (OR 1.48, p = 0.006). CABG increased the odds of deep surgical site infection 14.23-fold and CS 9.22-fold (p < 0.001). Postoperative pneumonia was increased in PM, CABG, and CS groups (OR 2.15,), (OR 2.21,), (OR 1.64,) (p < 0.001). CONCLUSIONS: Patients who have undergone cardiac intervention are generally at risk for adverse stays. Furthermore, risk factors and complications vary between the groups. Our analysis emphasizes the importance of individualized medical care and as a basis for electing and informing patients for TKA.


Assuntos
Artroplastia do Joelho , Complicações Pós-Operatórias , Humanos , Artroplastia do Joelho/estatística & dados numéricos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Estados Unidos/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Ponte de Artéria Coronária/estatística & dados numéricos , Stents , Marca-Passo Artificial/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Doenças Cardiovasculares/cirurgia
17.
J Cardiothorac Surg ; 19(1): 62, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38321546

RESUMO

BACKGROUND: Electrical storm (ES) is a clinical emergency characterized by multiple malignant ventricular arrhythmias or ICD discharges within 24 h, requiring early rational management. CASE PRESENTATION: We report a 55-year-old man who underwent aortic valve replacement experienced recurrent ventricular tachycardia/ventricular fibrillation. A temporary permanent pacemaker with the EnSite system was implanted, and significant inhibition of the electrical storm, attributed to the atrial overdrive pacing, ensued. CONCLUSIONS: In emergency regarding an electrical storm, the bedside temporary permanent pacemaker implantation with the EnSite system is concluded to be feasible and safe.


Assuntos
Marca-Passo Artificial , Taquicardia Ventricular , Masculino , Humanos , Pessoa de Meia-Idade , Valva Aórtica , Fluoroscopia , Resultado do Tratamento , Estimulação Cardíaca Artificial
18.
BMJ Case Rep ; 17(2)2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38331446

RESUMO

A woman in her 80s experienced a life-threatening complication of pacemaker implant consisting of subacute right ventricular lead perforation causing iatrogenic injury to an intercostal artery, resulting in a large haemothorax. A CT scan confirmed active bleeding from the fourth intercostal artery. The patient underwent cardiothoracic surgery via a median sternotomy approach, during which the source of the bleeding was sealed, a new epicardial lead was positioned, and the original lead was extracted. This case emphasises the potentially severe consequences of pacemaker lead perforation and secondary injury to adjacent structures. It underscores the importance of early recognition and timely intervention, preferably in a tertiary specialist unit equipped for cardiothoracic surgery and confirms the value of pacemaker interrogation and CT scans for diagnosis.


Assuntos
Traumatismos Cardíacos , Marca-Passo Artificial , Feminino , Humanos , Artérias , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/cirurgia , Hemorragia/diagnóstico por imagem , Hemorragia/etiologia , Hemorragia/terapia , Hemotórax/diagnóstico por imagem , Hemotórax/etiologia , Hemotórax/cirurgia , Doença Iatrogênica , Marca-Passo Artificial/efeitos adversos , Idoso de 80 Anos ou mais
20.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38340330

RESUMO

AIMS: A dual-chamber pacemaker with closed-loop stimulation (CLS) mode is effective in reducing syncopal recurrences in patients with asystolic vasovagal syncope (VVS). In this study, we explored the haemodynamic and temporal relationship of CLS during a tilt-induced vasovagal reflex. METHODS AND RESULTS: Twenty patients underwent a tilt test under video recording 3.9 years after CLS pacemaker implantation. Three patients were excluded from the analysis because of no VVS induced by the tilt test (n = 1) and protocol violation (n = 2). In 14 of the remaining 17 patients, CLS pacing emerged during the pre-syncopal phase of circulatory instability when the mean intrinsic heart rate (HR) was 88 ± 12 b.p.m. and systolic blood pressure (SBP) was 108 ± 19 mmHg. The CLS pacing rate thereafter rapidly increased to 105 ± 14 b.p.m. within a median of 0.1 min [inter-quartile range (IQR), 0.1-0.7 min] when the SBP was 99 ± 21 mmHg. At the time of maximum vasovagal effect (syncope or pre-syncope), SBP was 63 ± 17 mmHg and the CLS rate was 95 ± 13 b.p.m. The onset of CLS pacing was 1.7 min (IQR, 1.5-3.4) before syncope or lowest SBP. The total duration of CLS pacing was 5.0 min (IQR, 3.3-8.3). Closed-loop stimulation pacing was not observed in three patients who had a similar SBP decrease from 142 ± 22 mmHg at baseline to 69 ± 4 mmHg at the time of maximum vasovagal effect, but there was no significant increase in HR (59 ± 1 b.p.m.). CONCLUSION: The reproducibility of a vasovagal reflex was high. High-rate CLS pacing was observed early during the pre-syncopal phase in most patients and persisted, although attenuated, at the time of maximum vasovagal effect. REGISTRATION: ClinicalTrials.gov identifier: NCT06038708.


Assuntos
Marca-Passo Artificial , Síncope Vasovagal , Humanos , Estimulação Cardíaca Artificial/métodos , Hemodinâmica , Marca-Passo Artificial/efeitos adversos , Reprodutibilidade dos Testes , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/prevenção & controle , Teste da Mesa Inclinada/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA