Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Chromatogr Sci ; 59(3): 297-304, 2021 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-33275653

RESUMO

A validated method for preconcentration and determination of nateglinide in plasma was developed using vortex-assisted dispersive liquid-liquid microextraction. Different variables that affect extraction efficiency were studied and optimized, including type and volume of extractant, type and volume of disperser, pH of diluent, salt addition effect, centrifugation and vortex time. Nateglinide was extracted using 30 µL of 1-octanol as an extractant and 200 µL of methanol as a disperser. The enrichment factor reached 330 under the optimum conditions. High-performance liquid chromatography/ultraviolet was used for detection using phosphate buffer (pH 2.5, 10 mM): acetonitrile (45:55, v/v) as a mobile phase at a flow rate of 1 mL/min. The method was linear over the range of 50-20,000 ng/mL with a limit of detection of 15 ng/mL (signal-to-noise ratio = 3). Intra- and inter-day precision had %relative standard deviation <6% (n = 3) and the %recoveries were found to be between 102.5 and 105.9%. The proposed method is simple, sensitive, eco-friendly, cost-effective and powerful for microextraction of nateglinide from human plasma samples.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Microextração em Fase Líquida/métodos , Nateglinida/sangue , Humanos , Limite de Detecção , Modelos Lineares , Nateglinida/isolamento & purificação , Reprodutibilidade dos Testes , Espectrofotometria Ultravioleta
2.
J Chromatogr Sci ; 58(4): 309-322, 2020 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-31836899

RESUMO

Nateglinide (NAT) and Pioglitazone (PIO) are an antidiabetic drugs combination and currently under clinical trial in countries like Japan. In this study, an alternative, a simple, sensitive high-performance liquid chromatography method has been developed (limit of detection: 15 ng/mL and limit of quantification: 50 ng/mL) for simultaneous estimation of this drug combination in rat plasma. Most remarkably, bioavailability of NAT has been increased markedly on coadministration with PIO, than when it was administered alone. Thus, PIO is assumed to retard the catabolism of NAT by inhibiting metabolic liver-microsomal enzyme, especially CYP2C9. Using a Waters Nova-Pak C 18 column (150 × 3.9 mm, 4 µm) and a mobile phase of acetonitrile: 10 mM KH2PO4 (60: 40, V/V (volume by volume)) pH 3.5, the analysis was performed at 210 nm with a flow rate of 1.5 mL/min. In silico docking via molecular dynamics simulation revealed that NAT-CYP2C9 binding affinity may be reduced after PIO attachment, presumably due to the binding site overlapping of the two drugs. Thus, it has been proposed that NAT and PIO may be an efficient synergistic fixed dose combination against diabetes mellitus, and the above method can foster a simple but highly sensitive bioanalytical estimation for routine analysis.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Nateglinida/farmacocinética , Pioglitazona/farmacocinética , Administração Oral , Animais , Disponibilidade Biológica , Sistema Enzimático do Citocromo P-450/química , Sistema Enzimático do Citocromo P-450/metabolismo , Estabilidade de Medicamentos , Sinergismo Farmacológico , Hipoglicemiantes/farmacocinética , Limite de Detecção , Masculino , Camundongos , Microssomos Hepáticos/efeitos dos fármacos , Microssomos Hepáticos/metabolismo , Simulação de Dinâmica Molecular , Nateglinida/administração & dosagem , Nateglinida/sangue , Nateglinida/química , Pioglitazona/administração & dosagem , Pioglitazona/sangue , Pioglitazona/química , Ratos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA