Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
J Trauma Acute Care Surg ; 91(4): 663-671, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34225347

RESUMO

BACKGROUND: Valid and reliable assessment of skills is essential for improved and evidence-based training concepts. In a recent study, we presented a novel tool to assess procedural skills in resuscitative endovascular balloon occlusion of the aorta (REBOA), REBOA-RATE, based on international expert consensus. Although expert consensus is a strong foundation, the performance of REBOA-RATE has not been explored. The study aimed to examine the reliability and validity of REBOA-RATE. METHODS: This was an experimental simulation-based study. We enrolled doctors with three levels of expertise to perform two REBOA procedures in a simulated scenario of out-of-hospital cardiac arrest. Procedures were video-recorded, and videos were blinded and randomized. Three clinical experts independently rated all procedures using REBOA-RATE. Data were analyzed using Messick's framework for validity evidence, including generalizability analysis of reliability and determination of a pass/fail standard. RESULTS: Forty-two doctors were enrolled: 16 novices, 13 anesthesiologists, and 13 endovascular experts. They all performed two procedures, yielding 84 procedures and 252 ratings. The REBOA-RATE assessment tool showed high internal consistency (Cronbach's α = 0.95) and excellent interrater reliability (intraclass correlation coefficient, 0.97). Assessment using one rater and three procedures could ensure overall reliability suitable for high-stakes testing (G-coefficient >0.80). Mean scores (SD) for the three groups in the second procedure were as follows: novices, 32% (24%); anesthesiologists, 55% (29%); endovascular experts, 93% (4%) (p < 0.001). The pass/fail standard was set at 81%, which all experts but no novices passed. CONCLUSION: Data strongly support the reliability and validity of REBOA-RATE, which successfully discriminated between all experience levels. The REBOA-RATE assessment tool requires minimal instruction, and one rater is sufficient for reliable assessment. Together, these are strong arguments for the use of REBOA-RATE to assess REBOA skills, allowing for competency-based training and certification concepts. LEVEL OF EVIDENCE: Diagnostic test, no or poor gold standard, level V.


Assuntos
Oclusão com Balão/normas , Competência Clínica/normas , Procedimentos Endovasculares/educação , Parada Cardíaca Extra-Hospitalar/terapia , Ressuscitação/educação , Aorta/cirurgia , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/normas , Humanos , Masculino , Manequins , Reprodutibilidade dos Testes , Ressuscitação/métodos , Ressuscitação/normas , Treinamento por Simulação/métodos
2.
J Gastroenterol ; 56(6): 527-536, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33899159

RESUMO

BACKGROUND AND AIM: Endoscopic balloon dilation (EBD) is effective for esophageal stenosis caused by ESD. However, an efficient EBD method has not been established. We, therefore, conducted EBD experiments on porcine esophageal stenosis models. METHODS: Study 1: in dilation models (day 22 after ESD), the thickness of the outer muscle layer (as an index of the extension effect) and the area of muscle fiber bundle necrosis in the inner muscle layer (as an index of thermal damage) were evaluated. Study 2: in restenosis models (day 43 after ESD), the thickness of the fibrous plexus (as an index of restenosis) was evaluated. In total, 12 porcine models were created. RESULTS: Study 1: the thickness of the outer muscle layer was 1243 ± 322 µm in surrounding locations and it was 803 ± 145 µm beneath the laceration (p = 0.005). In cases of muscular layer injury, the area of necrosis was 15,500 ± 10400 µm2 in surrounding locations and it was 40,200 ± 12900 µm2 at the laceration site (p < 0.001). Study 2: the thickness of the fibrous plexus was 1359 ± 196 µm in surrounding locations and it was 1322 ± 136 µm2 in the laceration scar site (p = 0.74). CONCLUSION: Since thermal damage persists until the completion of stenosis, EBD in the initial stage should be carefully performed. An extension effect was observed only at the laceration site and it later returned to a status similar to that of surrounding locations. Additional intervention would be required for preventing restenosis.


Assuntos
Oclusão com Balão/normas , Ressecção Endoscópica de Mucosa/efeitos adversos , Estenose Esofágica/terapia , Animais , Oclusão com Balão/métodos , Oclusão com Balão/estatística & dados numéricos , Modelos Animais de Doenças , Ressecção Endoscópica de Mucosa/métodos , Japão , Suínos
4.
Medicina (Kaunas) ; 56(8)2020 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-32717928

RESUMO

Background and Objectives: Preoperative prophylactic balloon-assisted occlusion (PBAO) of the internal iliac arteries minimizes blood loss and facilitates surgery performance, through reductions in the rate of uterine perfusion, which allow for better control in hysterectomy performance, with decreased rates of bleeding and surgical complications. We aimed to investigate the maternal and fetal outcomes associated with PBAO use in women with placenta increta or percreta. Material and Methods: The records of 42 consecutive patients with a diagnosis of placenta increta or percreta were retrospectively reviewed. Of 42 patients, 17 patients (40.5%) with placenta increta or percreta underwent cesarean delivery after prophylactic balloon catheter placement in the bilateral internal iliac artery (balloon group). The blood loss volume, transfusion volume, postoperative hemoglobin changes, rates of hysterectomy and hospitalization, and infant Apgar score in this group were compared to those of 25 similar women who underwent cesarean delivery without balloon placement (surgical group). Results: The mean intraoperative blood loss volume in the balloon group (2319 ± 1191 mL, range 1000-4500 mL) was significantly lower than that in the surgical group (4435 ± 1376 mL, range 1500-10,500 mL) (p = 0.037). The mean blood unit volume transfused in the balloon group (2060 ± 1154 mL, range 1200-8000 mL) was significantly lower than that in the surgical group (3840 ± 1464 mL, range 1800-15,200 mL) (p = 0.043). There was no significant difference in the postoperative hemoglobin change, hysterectomy rates, length of hospitalization, or infant Apgar score between the groups. Conclusion: PBAO of the internal iliac artery prior to cesarean delivery in patients with placenta increta or percreta is a safe and minimally invasive technique that reduces the rate of intraoperative blood loss and transfusion requirements.


Assuntos
Oclusão com Balão/normas , Artéria Ilíaca/cirurgia , Placenta Acreta/cirurgia , Procedimentos Cirúrgicos Profiláticos/normas , Adulto , Oclusão com Balão/métodos , Oclusão com Balão/estatística & dados numéricos , Feminino , Humanos , Artéria Ilíaca/fisiopatologia , Placenta Acreta/fisiopatologia , Hemorragia Pós-Parto/prevenção & controle , Hemorragia Pós-Parto/cirurgia , Gravidez , Cuidados Pré-Operatórios/métodos , Procedimentos Cirúrgicos Profiláticos/métodos , Procedimentos Cirúrgicos Profiláticos/estatística & dados numéricos , Estudos Retrospectivos
5.
World J Emerg Surg ; 14: 35, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31346347

RESUMO

Background: Resuscitative endovascular balloon occlusion of the aorta (REBOA) for patients with traumatic torso hemorrhagic shock is available to keep a minimum level of circulatory status as a bridge to definitive therapy. However, the trajectory for placement of REBOA in the aorta has not yet been clearly defined. Methods: We conducted a retrospective observational cohort study in the two tertiary critical care and emergency center from December 2014 to October 2018. A total of 28 patients who underwent focused assessment with sonography for trauma (FAST) were studied via contrast computed tomography (CT), and 27 were analyzed. Results: We divided patients into two groups based on our CT findings. The REBOA deflate group included 16 patients, and the inflate group included 11 patients. The median trace value (interquartile range) of the blood vessel center line from the common femoral artery to the tip of REBOA (blood vessel length) and the length of REBOA itself from the common femoral artery to the tip of REBOA (REBOA insertion length) were 56.2 cm (54.5-57.2) and 55.2 cm (54.2-55.6), respectively (p < 0.0001) for the deflated group, and 51.4 cm (42.1-56.6) and 50.3 cm (42.3-55.0) (p = 0.594), respectively, for the inflated group. Conclusions: If REBOA was deflated, it was placed 1.0 cm longer than the insertion length of REBOA catheter itself, but that was not the case when inflating REBOA. The individual difference was large to the extent that the balloon inflated and the extent to which the balloon was pushed back toward the caudal depending on the degree of blood pressure. Further studies would be needed to validate the study findings.


Assuntos
Pontos de Referência Anatômicos , Aorta/anatomia & histologia , Oclusão com Balão/métodos , Cateterismo/métodos , Adulto , Oclusão com Balão/normas , Cateterismo/normas , Estudos de Coortes , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/normas , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Ressuscitação/métodos , Ressuscitação/normas , Estudos Retrospectivos
6.
J Emerg Med ; 56(4): 363-370, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30709605

RESUMO

BACKGROUND: Penetrating neck wounds are common in the civilian and military realms. Whether high or low velocity, they carry a substantial morbidity and mortality rate. OBJECTIVES: We endeavored to ascertain whether the iTClamp is equivalent to direct manual pressure (DMP) and Foley catheter balloon tamponade (BCT). METHODS: Using a perfused cadaver, a 4.5-cm wound was made in Zone 2 of the neck with a 1-cm carotid arteriotomy. Each of the hemorrhage control modalities was randomized and then applied to the wound separately. Time to apply the device and fluid loss with and without neck motion was recorded. RESULTS: There was no significant difference between the fluid loss/no movement (p > 0.450) and fluid loss/movement (p > 0.215) between BCT and iTClamp. There was significantly more fluid lost with DMP than iTClamp with no movement (p > 0.000) and movement (p > 0.000). The iTClamp was also significantly faster to apply than the Foley (p > 0.000). CONCLUSIONS: The iTClamp and BCT were associated with significantly less fluid loss than DMP in a perfused cadaver model. The iTClamp required significantly less time to apply than the BCT. Both the iTClamp and the BCT were more effective than simple DMP. The iTClamp offers an additional option for managing hard-to-control bleeding in the neck.


Assuntos
Hemorragia/cirurgia , Técnicas Hemostáticas/instrumentação , Equipamentos Cirúrgicos/normas , Procedimentos Cirúrgicos Operatórios/métodos , Ferimentos Penetrantes/terapia , Idoso , Idoso de 80 Anos ou mais , Oclusão com Balão/instrumentação , Oclusão com Balão/métodos , Oclusão com Balão/normas , Cadáver , Feminino , Hemorragia/prevenção & controle , Técnicas Hemostáticas/normas , Humanos , Masculino , Pescoço/patologia , Pescoço/cirurgia , Pressão , Ferimentos Penetrantes/cirurgia
7.
J Trauma Acute Care Surg ; 86(4): 625-634, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30633092

RESUMO

BACKGROUND: Minimally invasive preperitoneal balloon tamponade (PPB) and abdominal aortic junctional tourniquets (AAJT) have been proposed as alternatives to open preperitoneal packing (OP) for the management of pelvic fracture-associated hemorrhage. We hypothesized that the PPB (SpaceMaker Pro) and AAJT would result in similar rates of survival and blood loss versus OP. METHODS: Thirty-two swine underwent creation of a combined open-book pelvic fracture and major iliac vascular injuries. Animals were randomized to no intervention (n = 7), OP (n = 10), PPB (n = 9), or AAJT (n = 6) at a mean arterial pressure <40 mm Hg following initiation of uncontrolled hemorrhage. Survival (up to 60 minutes + 10 minutes after intervention reversal), hemodynamics, extraperitoneal pressures, blood loss, and associated complications were compared between groups. RESULTS: Prior to injury, no difference was measured between groups for weight, hemodynamics, lactate, and hematocrit (all p > 0.05). The injury was uniformly lethal without intervention, with survival time (mean) of 5 minutes, peak preperitoneal pressure (PP) of 14 mm Hg, blood loss of 960 g, and peak lactate of 2.6 mmol/L. Survival time was 44 minutes with OP versus 60 minutes with PPB and AAJT (p < 0.01). Peak PP (mm Hg) was 19 with OP, 23 with PPB, and 23 with AAJT (p > 0.05). Blood loss (g) was 850 with OP, 930 with PPB, and 600 with AAJT (p > 0.05). Peak lactate (mmol/L) was 3.3 with OP, 4.3 with PPB, and 6.3 with AAJT (p < 0.01). Only 33% of AAJT animals survived intervention reversal versus 60% for OP and 67% for PPB (p < 0.01). Necropsy revealed bowel/bladder injury in 50% of AAJT subjects versus 0% in all other arms (p < 0.01). CONCLUSION: Preperitoneal balloon tamponade is a safe and potentially effective alternative to OP for the management of lethal pelvic fracture-associated hemorrhage. Abdominal aortic junctional tourniquet offers a similar survival benefit to PPB but has concerning rates of ischemia-reperfusion and compressive abdominal organ injury.


Assuntos
Oclusão com Balão/normas , Bandagens , Fraturas Ósseas/cirurgia , Técnicas Hemostáticas , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Ossos Pélvicos/lesões , Torniquetes , Animais , Aorta Abdominal/cirurgia , Perda Sanguínea Cirúrgica , Hematócrito , Hemorragia/cirurgia , Técnicas Hemostáticas/normas , Veia Ilíaca/lesões , Veia Ilíaca/cirurgia , Ácido Láctico/sangue , Ossos Pélvicos/cirurgia , Peritônio/cirurgia , Suínos , Torniquetes/normas , Resultado do Tratamento
8.
Mil Med ; 184(3-4): e285-e289, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30085219

RESUMO

INTRODUCTION: Non-compressible torso hemorrhage accounts for 70% of battlefield deaths. Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an emerging technology used to mitigate massive truncal hemorrhage. Use of REBOA on the battlefield is limited by the need for radiographic guided balloon placement. Radiofrequency identification (RFID) is a simple, portable, real-time technology utilized to detect retained sponges during surgery. We investigated the feasibility of RFID to confirm the placement of ER-REBOA. MATERIALS AND METHODS: This was a single-arm prospective proof-of-concept experimental study approved by the institutional review board at Naval Medical Center San Diego. The ER-REBOA (Prytime Medical Devices, Inc, Boerne, TX, USA) was modified by placement of a RFID tag. The tagged ER-REBOA was placed in zone I or zone III of the aorta in a previously perfused cadaver. Exact location was documented with X-ray. Five blinded individuals used the RF Assure Detection System (Medtronic, Minneapolis, MN, USA) handheld detection wand to predict catheter tip location from the xiphoid process (zone I) or pubic tubercle (zone III). RESULTS: In zone I, actual distance (Da) of the catheter tip was 11 cm from the xiphoid process. Mean predicted distance (Dp) from Da was 1.52 cm (95% CI 1.19-1.85). In zone III, Da was 14 cm from the pubic tubercle. Mean Dp from Da was 4.11 cm (95% CI 3.68-4.54). Sensitivity of detection was 100% in both zones. Specificity (Defined as Dp within 2 cm of Da) was 86% in zone I and 16% in zone III. CONCLUSIONS: Using RFID to confirm the placement of ER-REBOA is feasible with specificity highest in zone I. Future work should focus on refining this technology for the forward-deployed setting.


Assuntos
Oclusão com Balão/normas , Hemorragia Gastrointestinal/terapia , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Oclusão com Balão/instrumentação , Oclusão com Balão/métodos , Cadáver , Feminino , Fluoroscopia/métodos , Hemorragia Gastrointestinal/prevenção & controle , Humanos , Estudos Prospectivos , Dispositivo de Identificação por Radiofrequência/métodos , Ressuscitação/instrumentação , Ressuscitação/métodos
9.
World J Emerg Surg ; 13: 49, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30386415

RESUMO

Background: Although resuscitative endovascular balloon occlusion of the aorta (REBOA) may be effective in trauma management, its effect in patients with severe multiple torso trauma remains unclear. Methods: We performed a retrospective study to evaluate trauma management with REBOA in hemodynamically unstable patients with severe multiple trauma. Of 5899 severe trauma patients admitted to our hospital between January 2011 and January 2018, we selected 107 patients with severe torso trauma (Injury Severity Score > 16) who displayed persistent hypotension [≥ 2 systolic blood pressure (SBP) values ≤ 90 mmHg] regardless of primary resuscitation. Patients were divided into two groups: trauma management with REBOA (n = 15) and without REBOA (n = 92). The primary endpoint was the effectiveness of trauma management with REBOA with respect to in-hospital mortality. Secondary endpoints included time from arrival to the start of hemostasis. Multivariable logistic regression analysis, adjusted for clinically important variables, was performed to evaluate clinical outcomes. Results: Trauma management with REBOA was significantly associated with decreased mortality (adjusted odds ratio of survival, 7.430; 95% confidence interval, 1.081-51.062; p = 0.041). The median time (interquartile range) from admission to initiation of hemostasis was not significantly different between the two groups [with REBOA 53.0 (40.0-80.3) min vs. without REBOA 57.0 (35.0-100.0) min ]. The time from arrival to the start of balloon occlusion was 55.7 ± 34.2 min. SBP before insertion of REBOA was 48.2 ± 10.5 mmHg. Total balloon occlusion time was 32.5 ± 18.2 min. Conclusions: The use of REBOA without a delay in initiating resuscitative hemostasis may improve the outcomes in patients with multiple severe torso trauma. However, optimal use may be essential for success.


Assuntos
Oclusão com Balão/métodos , Ressuscitação/métodos , Tronco/lesões , Adulto , Idoso , Aorta/lesões , Aorta/cirurgia , Oclusão com Balão/instrumentação , Oclusão com Balão/normas , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Feminino , Hemodinâmica/fisiologia , Humanos , Escala de Gravidade do Ferimento , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Ressuscitação/instrumentação , Estudos Retrospectivos , Estados Unidos , Ferimentos e Lesões/cirurgia
10.
World J Emerg Surg ; 13: 44, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30258488

RESUMO

Morbidly adherent placenta (MAP), which includes accreta, increta, and percreta, is a condition characterized by the invasion of the uterine wall by placental tissue. The condition is associated with higher odds of massive post-partum hemorrhage. Several interventions have been developed to improve hemorrhage-related outcomes in these patients; however, there is no evidence to prefer any intervention over another. Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an endovascular intervention that may be useful and effective to reduce hemorrhage and transfusions in MAP patients. The objective of this narrative review is to summarize the evidence for REBOA in patients with MAP. We posit that acute care surgeons can perform REBOA for patients with MAP.


Assuntos
Aorta/cirurgia , Oclusão com Balão/normas , Procedimentos Endovasculares/métodos , Doenças Placentárias/cirurgia , Adulto , Oclusão com Balão/métodos , Feminino , Humanos , Placenta/anormalidades , Gravidez , Ressuscitação/métodos , Ressuscitação/normas
11.
J Obstet Gynaecol Res ; 44(3): 456-462, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29297951

RESUMO

AIMS: We investigated whether common iliac artery balloon occlusion (CIABO) was effective for decreasing blood loss during cesarean hysterectomy (CH) in patients with placenta previa with accreta and was safe for mothers and fetuses. METHODS: Of the 67 patients who underwent CH for placenta previa with accreta at our facility from 1985 to 2014, 57 patients were eligible for the study. The amount of intraoperative bleeding during CH was compared between three groups: surgery without blood flow occlusion (13 patients), internal iliac artery ligation (15 patients) and CIABO (29 patients). Additionally, multivariate analysis was performed to assess risk factors for massive bleeding during CH. RESULTS: The mean blood loss in the CIABO group (2027 ± 1638 mL) was significantly lower than in the other two groups (3787 ± 2936 mL in the no occlusion, 4175 ± 1921 mL in the internal iliac artery ligation group; P < 0.05). Multivariate analysis showed that spontaneous placental detachment during surgery (odds ratio [OR] 49.174, 95% confidence interval [CI] 4.98-1763.67), a history of ≥ 2 cesarean sections (OR 9.226, 95% CI 1.07-231.15) and no use of CIABO (OR 26.403, 95% CI 3.20-645.17) were significantly related to massive bleeding during surgery. There was no case of necrosis resulting from ischemia. The mean radiation dose during balloon placement never exceeded the threshold value for fetal exposure. CONCLUSION: Bleeding during CH for placenta previa with accreta can be decreased by CIABO. This study also confirmed the safety of CIABO in regard to maternal lower limb ischemia and fetal radiation exposure during balloon placement.


Assuntos
Oclusão com Balão , Perda Sanguínea Cirúrgica/prevenção & controle , Cesárea , Histerectomia , Artéria Ilíaca , Placenta Acreta/cirurgia , Placenta Prévia/cirurgia , Adulto , Oclusão com Balão/efeitos adversos , Oclusão com Balão/métodos , Oclusão com Balão/normas , Cesárea/efeitos adversos , Cesárea/métodos , Cesárea/normas , Feminino , Humanos , Histerectomia/efeitos adversos , Histerectomia/métodos , Histerectomia/normas , Gravidez
12.
Circ J ; 82(3): 659-665, 2018 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-29225299

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) using a cryoballoon (CB) is utilized for treating atrial fibrillation. This study aimed to assess the effect of the procedural characteristics of CB-based PVI (CB-PVI) on late PV reconnections.Methods and Results:A total of 389 consecutive patients underwent the CB-PVI as their index procedure; 45 consecutive patients underwent re-do procedures (184±87 days after the index CB-PVI). A total of 146 of 178 PVs (82%) remained isolated. The occlusion grade was evaluated in 171 PVs. Complete PV occlusion by the CB (grade 4) was obtained in 122 of 171 PVs (71%) during the index CB-PVI and the PVI status was maintained in 111 PVs (91%). Among the remaining 49 CB-PVIs without complete PV occlusion (grades 1-3), 20 PVs (41%) had late PV reconnections despite successful PVI during the index CB-PVI. A "pull-down maneuver" was performed in 20 PVs because of leakage of blood at the inferior aspect of the PVs, and all those PVs with a successful pull-down maneuver maintained their PVI status. A multivariate analysis demonstrated that the presence of complete PV occlusion was the only independent predictor for persistence of PVI. CONCLUSIONS: The occlusion grade was a reliable predictor of the long-term durability of PVI.


Assuntos
Fibrilação Atrial/terapia , Oclusão com Balão/normas , Ablação por Cateter/métodos , Criocirurgia/métodos , Veias Pulmonares/fisiopatologia , Idoso , Fibrilação Atrial/cirurgia , Criocirurgia/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Terapia de Salvação/métodos , Resultado do Tratamento
13.
J Neurointerv Surg ; 10(8): 751-755, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29222393

RESUMO

PURPOSE: Stent retriever-based mechanical thrombectomy (MT) for emergent large vessel occlusions (ELVO) is often complicated by thrombus fragmentation causing distal embolization and embolization to new vascular territories. Well-established embolic protection approaches include proximal flow arrest and distal aspiration techniques during stent retriever maneuvers. Aiming at the reduction of thrombus fragmentation during MT we evaluated a technical approach combining proximal balloon occlusion together with direct thrombus aspiration during MT: the PROTECT technique. METHODS: We performed a case-control study comparing the PROTECT technique with sole distal aspiration during MT regarding technical and procedural parameters, n=200 patients with ELVO of either the terminus of the internal carotid artery or the proximal middle artery were included. RESULTS: PROTECT resulted in a shorter procedure time (29 vs 40 min; P=0.002), in a higher rate of successful recanalizations (100% vs 78%; P=0.001) and a higher rate of complete reperfusions (70% vs 39%; P<0.001) compared with sole distal aspiration during MT. CONCLUSION: The PROTECT technique is a promising new approach to significantly reduce thrombus fragmentation and, hence distal embolization during MT. This safe and efficient technique needs to be validated in larger trials to confirm our results.


Assuntos
Oclusão com Balão/normas , Embolização Terapêutica/normas , Procedimentos Endovasculares/normas , Stents , Acidente Vascular Cerebral/terapia , Trombectomia/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Oclusão com Balão/métodos , Estudos de Casos e Controles , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Feminino , Humanos , Trombose Intracraniana/diagnóstico por imagem , Trombose Intracraniana/terapia , Masculino , Pessoa de Meia-Idade , Stents/efeitos adversos , Acidente Vascular Cerebral/diagnóstico por imagem , Trombectomia/métodos , Resultado do Tratamento
14.
World J Emerg Surg ; 12: 30, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28725258

RESUMO

BACKGROUND: The objective of this systematic review and meta-analysis was to determine the effect of REBOA, compared to resuscitative thoracotomy, on mortality and among non-compressible torso hemorrhage trauma patients. METHODS: Relevant articles were identified by a literature search in MEDLINE and EMBASE. We included studies involving trauma patients suffering non-compressible torso hemorrhage. Studies were eligible if they evaluated REBOA and compared it to resuscitative thoracotomy. Two investigators independently assessed articles for inclusion and exclusion criteria and selected studies for final analysis. We conducted meta-analysis using random effect models. RESULTS: We included three studies in our systematic review. These studies included a total of 1276 patients. An initial analysis found that although lower in REBOA-treated patients, the odds of mortality did not differ between the compared groups (OR 0.42; 95% CI 0.17-1.03). Sensitivity analysis showed that the risk of mortality was significantly lower among patients who underwent REBOA, compared to those who underwent resuscitative thoracotomy (RT) (RR 0.81; 95% CI 0.68-0.97). CONCLUSION: Our meta-analysis, mainly from observational data, suggests a positive effect of REBOA on mortality among non-compressible torso hemorrhage patients. However, these results deserve further investigation.


Assuntos
Aorta/cirurgia , Oclusão com Balão/métodos , Procedimentos Endovasculares/métodos , Oclusão com Balão/normas , Oclusão com Balão/tendências , Constrição , Procedimentos Endovasculares/normas , Procedimentos Endovasculares/tendências , Humanos , Ressuscitação/métodos , Ressuscitação/mortalidade , Choque Hemorrágico/terapia , Análise de Sobrevida , Traumatismos Torácicos/terapia
16.
J Neurointerv Surg ; 7(4): 266-71, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24553343

RESUMO

BACKGROUND: Endovascular treatment of wide necked and large/giant intracranial aneurysms is challenging. The goal of this study was to evaluate the Liberty stent system in the rabbit elastase aneurysm model for 30, 90, and 180 days. METHODS: The Altes elastase model was used to create aneurysms in the right common carotid artery in New Zealand White rabbits. Safety was assessed by angiographic and histopathological data from treated wide necked aneurysms, treated subclavian arteries, and related vasculature immediately post-treatment and at scheduled end points. RESULTS: In this study, stenting of wide necked aneurysms demonstrated excellent results in all 35 animals. The Liberty could be tracked to the final position across an aneurysm neck precisely, without changing microcatheter position. After device deployment, no significant changes in vessel contour and no stent migration were observed. Coil mass was well supported in all aneurysms and high packing densities were achieved. In addition, follow-up angiograms showed stable coil masses and persistent occlusion in all animals, without any recanalization of the neck or aneurysmal sac. Furthermore, there was no evidence of coil compaction or protrusion of coil loop through the stent struts. None of the immediate post-coiling angiograms revealed evidence of vasospasm, dissection, or in-stent thrombosis. DISCUSSION: This animal study demonstrated promising results with the novel Liberty stent system. The Liberty showed consistent precise positioning and accurate deployment. The stent revealed good compatibility with embolic coiling procedures, while morbidity and mortality were negligible. In addition, persistent occlusion of aneurysms without recanalization or in-stent stenosis was observed at the 180 day follow-up.


Assuntos
Oclusão com Balão/normas , Modelos Animais de Doenças , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Stents/normas , Animais , Oclusão com Balão/efeitos adversos , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/cirurgia , Coelhos , Radiografia , Segurança , Stents/efeitos adversos
17.
J Neurointerv Surg ; 7(10): 770-6, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25179634

RESUMO

PURPOSE: To develop a reproducible technique for selective ophthalmic artery infusion chemotherapy (SOAIC) that is technically efficacious in children with unfavorable patterns of ophthalmic artery (OA) flow. MATERIALS AND METHODS: Initially, all SOAIC was performed with intention to treat using a standard selective OA (microcatheter) infusion technique (sSOAIC). Temporary balloon occlusion (TBO) of the external carotid artery (ECA), a balloon-assisted SOAIC (bSOAIC) technique, was performed only if OA angiography did not show robust and sustained anterograde OA flow. In our more recent experience, all SOAIC was performed with intention to treat by bSOAIC. Verapamil infusion into the OA and internal carotid artery was performed in selected cases. Technical success was defined as delivery of chemotherapeutic agent(s) into the OA with robust and sustained anterograde perfusion. sSOAIC was considered to have failed if converted to bSOAIC. RESULTS: 19 eyes were treated in 17 patients (age 5 months to 16 years) between December 2008 and May 2013. Eighty-three procedures were undertaken and the OA was successfully catheterized in all. Technical success was achieved in 35/41 (85%) sSOAIC cases and 42/42 (100%) bSOAIC cases. TBO of the ECA augmented anterograde OA flow and converted all cases of retrograde OA flow to anterograde. Verapamil further augmented anterograde ocular perfusion during SOAIC. There were no access site complications, strokes, or deaths. CONCLUSIONS: TBO of the ECA is a safe, effective, and reproducible method for optimizing ocular hemodynamics during SOAIC regardless of baseline OA flow pattern. Verapamil infusion may further favorably modify OA flow. TRIAL REGISTRATION NUMBER: NCT01466855.


Assuntos
Antineoplásicos/administração & dosagem , Oclusão com Balão/métodos , Artéria Carótida Externa , Neoplasias Oculares/tratamento farmacológico , Infusões Intra-Arteriais/métodos , Artéria Oftálmica , Avaliação de Resultados em Cuidados de Saúde , Retinoblastoma/tratamento farmacológico , Vasodilatadores/farmacologia , Verapamil/farmacologia , Adolescente , Oclusão com Balão/normas , Artéria Carótida Externa/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Artéria Oftálmica/diagnóstico por imagem , Radiografia , Vasodilatadores/administração & dosagem , Verapamil/administração & dosagem
18.
J Neurointerv Surg ; 7(10): 740-3, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25165384

RESUMO

BACKGROUND: Simultaneous use of balloon catheters with embolic materials can cause unwanted rupture of the balloon occlusion catheters, which might cause a serious problem. Therefore, knowledge of the compatibility of occlusion balloon catheters with liquid embolic materials is important in various interventional procedures. OBJECTIVE: To determine the compatibility of occlusion balloon catheters with commonly used embolic materials in vitro. METHODS: We used three types of occlusion balloon catheters (Scepter C, Microvention, Tustin, California, USA; Hyperform, Covidien, Irvine, California, USA; and Ascent, Codman Neurovascular, Raynham, Massachusetts, USA) to test their tolerances to Lipiodol, n-butyl cyanoacrylate (NBCA; Histoacryl; B Braun, Melsungen, Germany), and dimethyl sulfoxide (DMSO) with Onyx. The balloon was inflated just as it is in an endovascular procedure, then put on a Petri dish to observe its morphological change after one drop of liquid embolic material was added using a 1 mL syringe. The presence of rupture and the time to rupture were evaluated by constant video monitoring. Additionally, we observed morphological changes of the balloon catheter surface after contact with embolic materials with a scanning electron microscope. RESULTS: Lipiodol or a 33% NBCA-Lipiodol mixture dropping onto the three types of balloon catheter resulted in ruptures of all three. All three types of balloon catheter were tolerant to NBCA and to DMSO followed by Onyx. CONCLUSIONS: Glue embolization should not be performed with all three kinds of balloon catheter on the market, but DMSO and Onyx are compatible with those balloon catheters.


Assuntos
Antineoplásicos , Oclusão com Balão/normas , Neoplasias Encefálicas/terapia , Catéteres/normas , Quimioembolização Terapêutica/normas , Dimetil Sulfóxido , Embucrilato , Falha de Equipamento , Óleo Etiodado , Hemangioma/terapia , Polivinil , Solventes , Oclusão com Balão/instrumentação , Oclusão com Balão/métodos , Neoplasias Encefálicas/irrigação sanguínea , Quimioembolização Terapêutica/métodos , Hemangioma/irrigação sanguínea , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade
20.
Eur Radiol ; 21(1): 122-9, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20737152

RESUMO

PURPOSE: To evaluate the clinical safety and effectiveness of foam sclerotherapy using polidocanol for the treatment of gastric fundal varices by balloon-occluded retrograde transvenous obliteration (BRTO). MATERIALS AND METHODS: From November 2005 to June 2009, foam sclerotherapy using polidocanol for the treatment of gastric fundal varices by BRTO was performed in 16 patients (male/female 11:5; age range 46-84 years, median 67 years). Foam was made of 3% polidocanol (Aethoxysklerol; Kreussler Pharma, Wiesbaden, Germany), room air, and contrast media, with a ratio of 1:2:1, respectively. The amount of polidocanol (2-24 mL; median 7 mL) depended on the volume of varices. RESULTS: Technical success was achieved in 15 of 16 patients (93.8%). Technical failure occurred in one patient. All patients were without pain during sclerotherapy. One patient experienced pulmonary edema after the procedure but completely recovered with medical treatment. There was no procedure-related mortality. Patients were followed by endoscopy, computed tomography, or both. Four patients were lost to follow-up. Clinical success was achieved in 10 of 11 patients (91%). Rebleeding occurred in one case during follow-up. CONCLUSIONS: Foam sclerotherapy using polidocanol is clinically safe and effective for the treatment of gastric fundal varices during BRTO.


Assuntos
Oclusão com Balão/normas , Varizes Esofágicas e Gástricas/terapia , Hemorragia Gastrointestinal/terapia , Polietilenoglicóis/uso terapêutico , Escleroterapia/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polidocanol , Segurança , Soluções Esclerosantes/normas , Soluções Esclerosantes/uso terapêutico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA