J Feline Med Surg ; 26(3): 1098612X241231471, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38546192

RESUMO

OBJECTIVES: Systemic arterial hypertension is a common occurrence and can have serious adverse consequences in cats. Therefore, measuring blood pressure is very important. There are many indirect blood pressure measurement devices available. This study compared Doppler, oscillometric (petMAP Graphic II, SunTech Vet20, the Cardell Insight-X0000) and high-definition oscillometry devices for the non-invasive measurement of blood pressure in conscious cats. METHODS: In this prospective study, blood pressure was measured in 32 cats using the different devices according to the recommendations of the American College of Veterinary Internal Medicine Consensus Statement. Blood pressures (systolic blood pressure [SBP], diastolic blood pressure [DBP], mean arterial pressure [MAP]), time to complete measurements, number of attempts needed, coefficient of variation (CV) between the blood pressure measurements of the different devices, ease of completing measurements and apparent stress level of the cat were assessed. RESULTS: There was a significant difference between devices in the time taken to obtain blood pressure readings and the number of attempts necessary to obtain six reliable measurements. The CV of the Doppler device was significantly smaller than that of the rest of the devices, but there were no other differences between the devices. The mean SBP, DBP and MAP measured by the petMAP device were significantly higher than the measurements from the other devices. The perceived ease of measurement was not significantly different between the various machines. The perceived level of stress of measurement with the Doppler device was significantly higher compared with the other devices but did not lead to an increased SBP. CONCLUSIONS AND RELEVANCE: Using a Doppler device to measure blood pressure in conscious cats is fast, relatively easy and gives reliable results. A disadvantage is that the Doppler device can only measure SBP, while oscillometric devices also provide DBP and MAP. However, in veterinary medicine, systolic hypertension is considered the most relevant.


Assuntos
Determinação da Pressão Arterial , Ultrassom , Gatos , Animais , Pressão Sanguínea/fisiologia , Oscilometria/veterinária , Oscilometria/métodos , Estudos Prospectivos , Determinação da Pressão Arterial/veterinária
2.
J Feline Med Surg ; 23(2): 121-130, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32580610

RESUMO

OBJECTIVES: This study compared Doppler and oscillometric (PetMAP+) devices (with or without proprietary optimisations) for the non-invasive measurement of blood pressure in conscious cats. METHODS: Twenty-three cats were enrolled; however, five were excluded as fewer than five measurements were obtained for each assessment. All measurements were obtained according to American College of Veterinary Internal Medicine consensus guidelines. Oscillometric device modes A and B were operated according to the manufacturer's guidelines. Doppler and oscillometric devices were used alternately as the first device. RESULTS: Systolic arterial blood pressure (SAP) measurements were obtained by Doppler (SAPd) and oscillometry; the mean of each set of five values was used for statistical analysis. There was a significant difference between SAPd and SAP measurements in oscillometric modes A (P <0.001) and B (P <0.001). While both modes measured SAP higher than SAPd, B had a smaller bias (+15.72 mmHg) and narrower limits of agreement (LOA). There was also a significant difference between SAPd and mean arterial pressure (MAP) on oscillometric modes A (P = 0.002) and B (P <0.001). Both modes' MAP readings were lower than SAPd and oscillometric A MAP was closer to SAPd (-14.94 mmHg), with a smaller bias and narrower LOA. CONCLUSIONS AND RELEVANCE: The findings support that Doppler and oscillometric devices cannot be used interchangeably, with or without proprietary optimisations. Methodology should always be taken into account and reference intervals (RIs) need to be defined for the different methodologies. Until methodology-specific RIs are published, definitive diagnosis of hypertension and sub-staging of patients with kidney disease according to the International Renal Interest Society guidelines remains challenging.


Assuntos
Determinação da Pressão Arterial , Ultrassom , Animais , Pressão Sanguínea , Determinação da Pressão Arterial/veterinária , Monitores de Pressão Arterial , Gatos , Oscilometria/veterinária , Ultrassonografia Doppler/veterinária
3.
BMC Vet Res ; 14(1): 52, 2018 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-29482612

RESUMO

BACKGROUND: Rabbits are particularly sensitive to develop hypotension during sedation or anaesthesia. Values of systolic or mean non-invasive arterial blood pressure below 80 or 60 mmHg respectively are common under anaesthesia despite an ongoing surgery. A reliable method of monitoring arterial blood pressure is extremely important, although invasive technique is not always possible due to the anatomy and dimension of the artery. The aim of this study was to evaluate the agreement between a new oscillometric device for non-invasive arterial blood pressure measurement and the invasive method. Moreover the trending ability of the device, ability to identify changes in the same direction with the invasive methods, was evaluated as well as the sensibility of the device in identifying hypotension arbitrarily defined as invasive arterial blood pressure below 80 or 60 mmHg. RESULTS: Bland-Altman analysis for repeated measurements showed a poor agreement between the two methods; the oscillometric device overestimated the invasive arterial blood pressure, particularly at high arterial pressure values. The same analysis repeated considering oscillometric measurement that match invasive mean pressure lower or equal to 60 mmHg showed a decrease in biases and limits of agreement between methods. The trending ability of the device, evaluated with both the 4-quadrant plot and the polar plot was poor. Concordance rate of mean arterial blood pressure was higher than systolic and diastolic pressure although inferior to 90%. The sensibility of the device in detecting hypotension defined as systolic or mean invasive arterial blood pressure lower than 80 or 60 mmHg was superior for mean oscillometric pressure rather than systolic. A sensitivity of 92% was achieved with an oscillometric measurement for mean pressure below 65 mmHg instead of 60 mmHg. Non-invasive systolic blood pressure is less sensitive as indicator of hypotension regardless of the cutoff limit considered. CONCLUSIONS: Although mean invasive arterial blood pressure is overestimated by the device, the sensitivity of this non-invasive oscillometric monitor in detecting invasive mean pressure below 60 mmHg is acceptable but a cutoff value of 65 mmHg needs to be used.


Assuntos
Monitores de Pressão Arterial/veterinária , Coelhos/fisiologia , Anestesia Geral/efeitos adversos , Anestesia Geral/métodos , Anestesia Geral/veterinária , Animais , Pressão Sanguínea , Feminino , Masculino , Oscilometria/métodos , Oscilometria/veterinária , Estudos Prospectivos
4.
Vet Anaesth Analg ; 44(3): 492-501, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28528758

RESUMO

OBJECTIVE: To assess agreement between noninvasive blood pressure (NIBP) oscillometrically-derived values from a multiparameter monitor (Datex Ohmeda S/5 Compact) with those obtained by invasive blood pressure (IBP) measurement in anaesthetised horses undergoing elective surgery. STUDY DESIGN: Prospective clinical study. ANIMALS: A total of 40 healthy adult horses. METHODS: Horses were anaesthetised with various anaesthetic protocols (based on clinical requirements). Depending on positioning, cannulation of the facial or lateral metatarsal artery was performed for IBP measurement. The cannula was connected via a transducer to the monitor. An appropriately sized NIBP cuff was placed around the tail base and connected to the same monitor. Systolic (SAP), mean (MAP) and diastolic (DAP) arterial blood pressures were continuously recorded from the invasive system, and at 3 minute intervals from the oscillometric system, throughout the surgical procedure using a Datex iCollect program. An appropriate arithmetic correction factor was applied to the oscillometric results where the cuff was not level with the heart. Assessment of the degree of agreement between invasive and noninvasive readings at each time point was performed using a modified Bland-Altman analysis. RESULTS: While in many horses there was relatively close correlation between the values obtained over time, there was substantial variability in individual animals which resulted in wide Bland-Altman limits of agreement. The oscillometric device over-reads by approximately 32, 23 and 22 mmHg, and under-reads by 26, 17 and 19 mmHg for SAP, MAP and DAP, respectively, compared with the IBP values. However, using the mean difference and standard deviation, the device conforms to American College of Veterinary Internal Medicine (ACVIM) standards. CONCLUSIONS AND CLINICAL RELEVANCE: Oscillometric blood pressure measurement using the Datex Ohmeda S/5 Compact multiparameter monitor conforms to ACVIM standards when the NIBP cuff is placed on the tail. However, because of the wide variability in measurements, we cannot recommend this technique to guide therapy in anaesthetised adult horses.


Assuntos
Anestesia/veterinária , Determinação da Pressão Arterial/veterinária , Monitores de Pressão Arterial/veterinária , Oscilometria/veterinária , Anestesia/métodos , Animais , Pressão Sanguínea , Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/normas , Monitores de Pressão Arterial/normas , Procedimentos Cirúrgicos Eletivos/veterinária , Cavalos , Medicação Pré-Anestésica/métodos , Medicação Pré-Anestésica/veterinária , Estudos Prospectivos
5.
Arq. bras. med. vet. zootec ; 68(3): 611-619, tab, graf
Artigo em Português | LILACS, VETINDEX | ID: lil-785682

RESUMO

Após validação de dois diferentes métodos de mensuração de pressão arterial sistólica (PAS) não invasivos ou indiretos (oscilométrico e Doppler vascular) com o invasivo ou direto (cateterização arterial - padrão ouro) em 12 gatos hígidos anestesiados de mesma faixa etária, os métodos não invasivos foram avaliados e comparados em 24 gatos hígidos e conscientes, divididos em quatro grupos de idade. Em cada animal, procedeu-se à mensuração da pressão pelos métodos Doppler e oscilométrico. O método oscilométrico foi o primeiro a ser realizado, e, logo em seguida, o método Doppler. Os valores considerados foram obtidos das médias de sete medidas consecutivas para cada método, com intervalo de 30 segundos entre elas. A primeira medida e as medidas discrepantes (variação ˃ 20% PAS), obtidas com sinais óbvios de estresse e/ou com movimentação do animal, foram descartadas. Os métodos de mensuração oscilométrico e Doppler, embora tenham apresentado médias estatisticamente diferentes em todos os grupos, quando comparados em cada grupo, apresentaram uma correlação significativa, alta e positiva. Ou seja, sempre que for obtido um valor elevado por um método, o mesmo fato ocorrerá com o outro método e vice-versa. Clinicamente, a diferença observada não é relevante, uma vez que a diferença média dos valores obtida pelos dois métodos, em cada grupo, foi menor que 1,1%.(AU)


After two different validation systolic blood pressure measurement methods (PAS), not invasive or indirect (oscillometric and doppler vascular) with invasive or direct (arterial catheterization - Gold Standard) in 12 anesthetized healthy cats of the same age group, not invasive methods were evaluated and compared in 24 healthy conscious cats, divided into four age groups. In each animal, we proceeded to measure the pressure by Doppler and oscillometric methods. The oscillometric method was the first to be performed, and, shortly thereafter, the doppler method. The values considered were obtained from averages from seven consecutive measurements for each method with an interval of thirty seconds between them. The first measurement and disparate measurements (range ˃ 20% PAS) obtained with obvious signs of stress and / or animal movement were discarded. Methods of oscillometric and doppler measurement, although statistically different averages were shown in all groups when compared, each group showed a significant high positive correlation, meaning that when a high value is obtained by a method, the same occurs with the other method, and vice versa. Clinically, the observed difference is not relevant since the mean difference values obtained by the two methods, in each group was lower than 1.1%.(AU)


Assuntos
Animais , Gatos , Anestesia/veterinária , Pressão Arterial , Pressão Sanguínea , Cateterismo/veterinária , Oscilometria/veterinária , Hipertensão/veterinária , Fenômenos Fisiológicos
6.
J Feline Med Surg ; 17(2): 94-100, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24782457

RESUMO

The objective of this study was to determine the influence of the observer's level of experience on within- and between-day variability, and the percentage of successful systolic (SAP) and diastolic arterial blood pressure (DAP) measurements obtained by Doppler ultrasonography (DU) in awake cats. For this purpose, six healthy conscious cats were used and four observers with different levels of training performed 144 SAP and DAP measurements on 4 days using DU. Measurements were recorded five consecutive times, and mean values were used for statistical analysis. Only the two most skilled observers - a PhD student in cardiology and a Dipl ECVIM-CA (cardiology) - had within- and between-day coefficients of variation (CVs) for SAP ⩽16% (13-16%). Conversely, the two less experienced observers - a fifth-year student and an assistant - had high between-day CVs (61% and 73%). For DAP, only the most experienced observer (Dipl ECVIM-CA) succeeded in 100% of the attempts, with within- and between-day CVs of 11% and 4%, respectively. Conversely, DAP could not be measured by the other three observers in 8%, 19% and 56% of attempts (from the highest to the lowest level of experience); therefore, the corresponding CV values could not be calculated. In conclusion, SAP may be assessed using DU in healthy awake cats with good repeatability and reproducibility by a well-trained observer. Measurement of DAP is more difficult than of SAP, and needs a longer training period, which represents one of the limitations of DU in cats.


Assuntos
Determinação da Pressão Arterial/veterinária , Gatos/fisiologia , Ultrassonografia Doppler/veterinária , Animais , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Estado de Consciência , Oscilometria/veterinária , Valores de Referência , Reprodutibilidade dos Testes , Ultrassonografia Doppler/métodos
7.
Pesqui. vet. bras ; 34(supl.1): 87-91, dez. 2014. tab, graf
Artigo em Português | LILACS, VETINDEX | ID: lil-778358

RESUMO

A obesidade é o problema nutricional que mais acomete os cães e pode causar vários efeitos deletérios a saúde animal. No entanto, o efeito desta condição sobre a pressão arterial sistólica (PAS) em cães obesos é controverso. Os métodos indiretos de mensuração da PAS são os mais comumente utilizados na medicina veterinária para o diagnóstico da hipertensão sistêmica, por serem mais práticos e de fácil acesso. Não foram localizados na literatura estudos que tenham comparado os dois métodos para esta avaliação em cães obesos. Diante do exposto, o objetivo desse estudo foi avaliar a PAS em cães obesos, comparando os métodos indiretos de mensuração da pressão arterial, oscilométrico e doppler ultrassônico, a fim de verificar as diferenças nos valores obtidos, como também o método mais indicado para aferir a PAS em cães nesta condição. Foram avaliados 50 cães, incluindo 25 obesos com escore de condição corporal (ECC) médio de 8,42±0,50 e 25 cães com peso corporal ideal com ECC médio de 4,56±0,51. Os resultados revelaram valores superiores da PAS obtidos pelo método doppler (152±16mmHg) comparados ao oscilométrico (136±11mmHg). A análise de correspondência determinada por análise estatística multivariada demonstrou maior correspondência entre a condição corporal e o método de avaliação da PAS. Esses achados sugerem que o método indireto doppler pode aferir com mais precisão os valores de PAS em cães obesos.(AU)


Obesity is the most common nutritional problem in dogs and it can cause various harmful effects on animal health. However, the effect of this condition on systolic blood pressure (SBP) in obese dogs is controversial. The indirect method of measuring PAS is the most commonly used in veterinary medicine for the diagnosis of systemic hypertension, because it is more practical and easy to access. There is little scientific information about the comparison of the two non-invasive methods of measurement of blood pressure in obese dogs. Therefore, the objective of this study was to evaluate the SBP in obese dogs by comparing both indirect methods of measuring blood pressure, with oscillometric and doppler vascular in order to verify the differences in blood pressure values, but also the best method to assess the SBP dogs in this body score condition. The study complain blood pressure measurement of 50 dogs, with were divided in obese dogs with mean body condition score (BCS) of 8.42±0.50 (n=25) and dogs with ideal BCS of 4.56±0.51 (n=25). At comparison of blood pressure values, SBP values obtained by doppler method (152±16mmHg) were higher than the oscillometric (136±11mmHg). Correspondence analysis determined by multivariate statistical analysis showed correlation between body condition and the procedure of the SBP. These findings suggest that the indirect method doppler can better reflect the SBP in obese dogs.(AU)


Assuntos
Animais , Cães , Oscilometria/veterinária , Determinação da Pressão Arterial/veterinária , Ultrassonografia Doppler/veterinária , Obesidade/veterinária
8.
J Feline Med Surg ; 14(12): 906-9, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22832888

RESUMO

Hypertension is a common condition of older cats and acquiring clinically relevant and repeatable blood pressure (BP) measurements in conscious cats is important in its diagnosis and management. The most common sites for indirect BP measurement in the cat are the radial artery (RA) and the coccygeal artery (CA) but, to date, there are no published data comparing how conscious cats tolerate BP measurements from these sites. A high-definition oscillometric BP monitor was used to measure BP in 30 cats admitted to a cat-only veterinary clinic for reasons other than hypertension. Systolic arterial pressure (SAP), mean arterial pressure (MAP) and diastolic arterial pressure (DAP) were measured using the RA and CA, alternating which site was used first. The number of failed attempts and total time to achieve six measurements was recorded. Measurement of BP using the CA was better tolerated than the RA, resulting in fewer failures and shorter total time required. SAP measurements were slightly higher from the CA compared with the RA, irrespective of which site was used first. There were no significant differences in MAP and DAP. The coccygeal artery appears to be the more appropriate site to use when measuring BP in conscious cats using this oscillometric machine. Further studies are required using alternative BP monitors, including Doppler machines, to establish whether this is a consistent finding. When measuring BP in cats the site used should be recorded and the same site used for all subsequent measurements from the same cat.


Assuntos
Determinação da Pressão Arterial/veterinária , Monitores de Pressão Arterial/veterinária , Estado de Consciência , Oscilometria/veterinária , Artéria Radial , Região Sacrococcígea , Animais , Pressão Sanguínea , Determinação da Pressão Arterial/métodos , Monitores de Pressão Arterial/normas , Doenças do Gato/diagnóstico , Gatos , Feminino , Masculino , Oscilometria/métodos , Valores de Referência
9.
J Feline Med Surg ; 13(1): 35-43, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21215947

RESUMO

PRACTICAL RELEVANCE: the clinical importance of feline hypertension has been recognised for many years and most feline practitioners are quite familiar with this syndrome. Once systemic hypertension is identified, long-term management of the patient is needed to avoid catastrophic (eg, blindness due to retinal detachment) or subtle (eg, accelerated renal damage) target organ damage. PATIENT GROUP: feline systemic hypertension is most commonly a complication of renal disease and hyperthyroidism, both diseases of older feline patients. By 15 years of age, the probability of having at least one of these two diseases is high. As well cared for cats are living longer, optimal long-term management of feline hypertension in patients with concurrent diseases is an issue of clinical importance. CLINICAL CHALLENGES: obtaining accurate blood pressure measurements in patients that are anxious, fractious or just plain uncooperative remains a significant issue in feline medicine, as does confident analysis of results from these patients. DIAGNOSTICS: careful measurement of systolic blood pressure using Doppler or oscillometric techniques in conjunction with evaluation for evidence of hypertensive choroidopathy (funduscopic examination) and hypertensive cardiac changes (thoracic auscultation) are essential to the diagnosis of systemic hypertension in cats. Other diagnostic techniques, including evaluation of renal and thyroid function, are needed to detect the underlying disease condition. EVIDENCE BASE: numerous well-designed clinical studies have greatly advanced our understanding of the most appropriate methods of diagnosis and therapy of feline hypertension.


Assuntos
Doenças do Gato/diagnóstico , Doenças do Gato/terapia , Hipertensão/veterinária , Animais , Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/veterinária , Gatos , Feminino , Membro Anterior/irrigação sanguínea , Hipertensão/diagnóstico , Hipertensão/terapia , Manometria/veterinária , Oscilometria/veterinária , Cauda/irrigação sanguínea
10.
Pneumologie ; 64(7): 452-3, 2010 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-20632242

RESUMO

Nasal airflow resistance in brachycephalic dogs is significantly elevated compared to normal dogs. LaserAssisted TurbinEctomy (LATE)-surgery as well as xylometazolin were shown to reduce pathologically increased intranasal airway resistance in brachycephalic dogs by approximately 50 %. Impulse oscillometry provides a reliable and sensitive method to examine intranasal stenoses in the canine nose. Acoustic rhinometry allows assessment of changes in cross sectional area and volume of the canine nasal cavity.


Assuntos
Resistência das Vias Respiratórias/fisiologia , Craniossinostoses/fisiopatologia , Craniossinostoses/veterinária , Doenças do Cão/fisiopatologia , Obstrução Nasal/fisiopatologia , Obstrução Nasal/veterinária , Nariz/anormalidades , Nariz/fisiopatologia , Animais , Craniossinostoses/cirurgia , Doenças do Cão/cirurgia , Cães , Terapia a Laser/veterinária , Obstrução Nasal/cirurgia , Nariz/cirurgia , Oscilometria/veterinária , Rinometria Acústica/veterinária , Conchas Nasais/cirurgia
11.
J Feline Med Surg ; 12(10): 731-7, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20615734

RESUMO

Indirect blood pressure measurements using high definition oscillometric (HDO) and Doppler devices were compared in 50 anaesthetised client-owned cats presented for various surgical procedures. Sites of cuff placement for Doppler were identified as forelimb and hindlimb and for HDO as forelimb and tail. Oscillometric and Doppler readings were obtained in 90.05% and 100% of attempts, respectively. Both devices enabled precise measurement of systolic arterial pressure (SAP), although the Doppler device gave higher precision. In the low pressure group (SAP<100 mmHg; n=30), 66.7% biases were within 10 mmHg of discrepancy, but in groups of normal (100 mmHg ≤ SAP ≤ 150 mmHg; n=120) and high measurements (SAP>150 mmHg; n=62), 86.7% and 75.0% of discrepancy, respectively, were lower than 10 mmHg. Frequency of discrepancy at the range of 15 mmHg showed similar differences between pressure groups. There were significantly higher discrepancies when the cuff was positioned on the tail rather than on the leg. The SAP value obtained by HDO can be calculated from the Doppler measurement from SAP (HDO)=0.8515 × SAP (Doppler)+19.221 mmHg. Compared to Doppler, HDO overestimated low pressure and underestimated high pressure values.


Assuntos
Anestesia/veterinária , Determinação da Pressão Arterial/veterinária , Oscilometria/veterinária , Ultrassonografia Doppler/veterinária , Animais , Determinação da Pressão Arterial/instrumentação , Determinação da Pressão Arterial/métodos , Gatos , Feminino , Membro Anterior , Membro Posterior , Masculino , Oscilometria/instrumentação , Oscilometria/métodos , Reprodutibilidade dos Testes , Cauda , Ultrassonografia Doppler/instrumentação , Ultrassonografia Doppler/métodos
12.
Biol. Res ; 41(1): 51-57, 2008. ilus, tab
Artigo em Inglês | LILACS | ID: lil-490632

RESUMO

Circadian rhythmicity of physiological processes in animals has been described for some variables. In order to investigate the daily rhythmicity of blood pressure, seven foals (Equus caballus) were used for 40 days after birth. Measurements of blood pressure were done by means of an oscillometric apparatus (Argus TM-7, Schiller, Barr Switzerland) with the foals in a standing position and the cuff placed around the tail. Blood pressure was recorded twice a day, 1 hour before dawn and 1 hour before dusk for the first 10 days of life, every 2 days from the 11th to the 32nd day, on the 36th and on the 40th day. Two-way repeated measures analysis of variance (ANOVA) were used to determine statistically significant differences between the mean values recorded at dawn and dusk during the study. Analysis of variance showed a significant effect of time (p<0.0001), during the first 40 days of life. This study confirms a strong correlation between age and blood pressure in horse and the absence of blood pressure maturation in foals 40 days old. The results on the maturation of the daily rhythm of blood pressure in foals is a contribution to the study of the development of circadian rhythms in mammals. These results are also useful for the chronophysiological assessment of blood pressure in the horse.


Assuntos
Animais , Animais Recém-Nascidos/fisiologia , Pressão Sanguínea/fisiologia , Ritmo Circadiano/fisiologia , Cavalos/fisiologia , Determinação da Pressão Arterial/veterinária , Oscilometria/veterinária , Fatores de Tempo
13.
J Feline Med Surg ; 7(3): 147-52, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15922221

RESUMO

Indirect blood pressure measurements were compared in 28 conscious cats using Doppler and oscillometric blood pressure-measuring devices. Ten cats were used to compare Doppler measurements between two examiners and 18 cats were used to compare Doppler and oscillometric measurements. The Doppler machine obtained systolic and diastolic blood pressure readings in 100% and 51% of attempts, respectively. With the oscillometric machine, systolic and diastolic blood pressure readings were obtained in 52% of the attempts. With the Doppler, measures of mean systolic blood pressure between two examiners were positively correlated, but there was no correlation for diastolic blood pressure measures. When comparing the results obtained by Doppler and oscillometric machines there was no significant difference between mean systolic blood pressure readings, but the oscillometric machine produced significantly higher estimates of diastolic blood pressure. In both cases, the standard deviations for the oscillometric machine were considerably larger than those for the Doppler machine. The first reading of systolic blood pressure obtained with the Doppler machine was an excellent predictor of the mean of five readings, but this was not so for the oscillometric machine. It took less than 5 min to obtain five readings in 37.5% of cases with the Doppler machine but this was true for only 5% of cases with the oscillometric machine. Two cats with ophthalmological lesions consistent with systemic hypertension were identified. In these two patients, systolic blood pressure measurements were between 200 and 225 mmHg when measured by Doppler, and between 140 and 150 mmHg when measured by the oscillometric machine. This suggests that a lower reference range for normal systolic blood pressure values should be used for the oscillometric device.


Assuntos
Determinação da Pressão Arterial/veterinária , Oscilometria/veterinária , Ultrassonografia Doppler/veterinária , Animais , Determinação da Pressão Arterial/métodos , Doenças do Gato/diagnóstico por imagem , Gatos , Estado de Consciência , Masculino , Oscilometria/métodos , Valores de Referência , Sensibilidade e Especificidade , Ultrassonografia Doppler/métodos
14.
Vet Surg ; 27(4): 370-7, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9662782

RESUMO

OBJECTIVE: To determine the accuracy of three indirect blood pressure monitoring techniques (oscillometric technique [OS], Doppler [DOP], and optical plethysmography [OP] [blood pressure determined with a pulse oximeter waveform]) when compared with direct arterial pressure measurement in cats. STUDY DESIGN: Prospective study. ANIMAL POPULATION: Eight healthy (five female, three male), domestic short-hair cats weighing 3.5 +/- 0.8 kg METHODS: Cats were anesthetized with isoflurane. The inspired concentration of isoflurane was adjusted to produce mild hypotension (80 to 100 mm Hg direct systolic), moderate hypotension (60 to 80 mm Hg direct systolic), and severe hypotension (< 60 mm Hg direct systolic). Indirect pressure measurements were obtained from the thoracic limb and compared with concurrent direct measurement using regression analysis and a modification of Bland and Altman's technique. RESULTS: All three techniques underestimated systolic pressure. OS produced the best prediction of systolic pressure with a bias +/- precision of -15.9 +/- 8.1 mm Hg. DOP and OP were relatively inaccurate with a bias +/- precision of -25 +/- 7.4 mm Hg and -25 +/- 7.5 mm Hg. All three techniques correlated well with direct pressure with r values of 0.81, 0.88, and 0.88 for OS, DOP, and OP. DOP and OP provided an accurate prediction of direct mean arterial pressure with a bias +/- precision of -0.8 +/- 6 mm Hg and 0.6 +/- 5.5 mm Hg. Correlation was good between DOP and mean arterial pressure with r = 0.89. Correlation was also good between OP and mean arterial pressure with r = 0.90. CONCLUSIONS: OS provided the most accurate prediction of direct systolic pressure. DOP and OP provided a good prediction of mean arterial pressure in the cat. CLINICAL RELEVANCE: All three of these techniques are useful for detecting trends. Direct monitoring of blood pressure should be considered if accurate blood pressure measurement is required.


Assuntos
Anestesia/veterinária , Determinação da Pressão Arterial/veterinária , Pressão Sanguínea , Gatos/fisiologia , Monitorização Intraoperatória/veterinária , Análise de Variância , Animais , Determinação da Pressão Arterial/métodos , Feminino , Fluxometria por Laser-Doppler/veterinária , Masculino , Monitorização Intraoperatória/métodos , Oscilometria/veterinária , Oximetria/veterinária , Pletismografia/veterinária , Estudos Prospectivos , Análise de Regressão
15.
Res Vet Sci ; 57(3): 265-9, 1994 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-7871243

RESUMO

Oscillometric measurements of arterial blood pressure were compared with direct measurements in anaesthetised dogs being monitored during routine surgery. Readings were obtained with tail cuffs and limb cuffs and the reproducibility (precision) of the readings from various cuff sites was also compared in conscious dogs. Tail cuffs gave the best precision in conscious dogs and the closest correlation with direct measurements in anaesthetised dogs, especially for systolic pressure. The proximal hindlimb site gave results with a slightly lower precision.


Assuntos
Determinação da Pressão Arterial/veterinária , Pressão Sanguínea , Cães/fisiologia , Anestesia Geral/veterinária , Animais , Determinação da Pressão Arterial/métodos , Cães/cirurgia , Membro Posterior , Monitorização Intraoperatória/métodos , Monitorização Intraoperatória/veterinária , Oscilometria/veterinária , Reprodutibilidade dos Testes , Cauda
17.
Vet Res Commun ; 17(2): 143-51, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8212524

RESUMO

The effects of clenbuterol (Ventipulmin, Boehringer Ingelheim) on respiratory functions were investigated in 6 calves aged 4-6 weeks prior to and after experimental infection with Pasteurella haemolytica A1. On days 1-3 (prior to infection) and on days 7-9 (after infection), blood gas analysis, monofrequency forced oscillation techniques and clinical examinations (heart rate, respiratory rate) were conducted for 135 min after the intravenous administration of clenbuterol (0.8 microgram/kg body weight). In healthy calves prior to Pasteurella infection, intravenous administration of clenbuterol induced a mild tachycardia and a reduction in the mean oscillatory respiratory resistance. Using the same dose of clenbuterol in diseased calves after infection, the statistically significant reduction in oscillatory respiratory resistance was more impressive and it was accompanied by a significant increase in the oxygen pressure of the arterialized blood. Heart rate and respiratory rate did not change significantly after the administration of clenbuterol in infected calves.


Assuntos
Clembuterol/farmacologia , Pasteurelose Pneumônica/tratamento farmacológico , Respiração/efeitos dos fármacos , Doença Aguda , Animais , Gasometria/veterinária , Dióxido de Carbono/sangue , Bovinos , Clembuterol/administração & dosagem , Clembuterol/uso terapêutico , Feminino , Frequência Cardíaca/efeitos dos fármacos , Injeções Intravenosas/veterinária , Masculino , Oscilometria/veterinária , Oxigênio/sangue