Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Laryngoscope ; 131(5): E1434-E1442, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33210744

RESUMO

OBJECTIVE: The objective of the study was to demonstrate the long-term outcomes of patients implanted with the active middle ear implant (AMEI) Vibrant Soundbridge (VSB) through coupling the floating mass transducer (FMT) to the round window (RW). METHODS: This retrospective study evaluated the short- and long-term clinical performance (audiological outcomes) and safety (revisions/explantations) of the VSB coupled to the RW between 2013 and 2019 at the St. Pölten University Hospital, Austria. For the outcome analysis, the sample was divided into a short-term examination group followed up for less than 12 months (<12 months) and a long-term examination group followed up for more than 12 months (>12 months). Cumulative survival outcomes were separately analyzed for subjects with and without cholesteatoma. RESULTS: 46 patients with an average long-term follow-up period of 31.43 months (13-75 months) were investigated. Complications requiring revision surgery were reported in total in seven patients with cholesteatoma (15.2%) and none in subjects without cholesteatoma (0%). Residual hearing was not affected by VSB surgery. Word understanding on the Freiburger monosyllabic speech test improved significantly at 65 dB (P < .0001) and 80 dB (P < .0001), and these outcomes were stable for long-term follow up. CONCLUSION: The VSB coupled to the RW is a safe implantation method for patients with conductive or mixed hearing loss. Hearing improvement was stable for the long-term follow-up up to 74 months. The revision rates are directly related to the underlying pathology of cholesteatoma (with radical cavity); thus, this special cohort requires additional counseling on potential complications. LEVEL OF EVIDENCE: 4 (Case-series) Laryngoscope, 131:E1434-E1442, 2021.


Assuntos
Colesteatoma da Orelha Média/cirurgia , Perda Auditiva Condutiva/cirurgia , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Substituição Ossicular/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Janela da Cóclea/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Áustria/epidemiologia , Colesteatoma da Orelha Média/complicações , Remoção de Dispositivo/estatística & dados numéricos , Feminino , Seguimentos , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/etiologia , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prótese Ossicular/efeitos adversos , Substituição Ossicular/instrumentação , Substituição Ossicular/métodos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
2.
HNO ; 68(Suppl 2): 106-115, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32725263

RESUMO

Here, we describe the surgical technique for implanting a new, active, transcutaneous bone conduction hearing aid. The implant technology is based on a system that has been in use reliably since 2012. The geometry of the new implant has been adapted based on experience with previously introduced implants. The surgery was feasible, standardized, and safe. Due to the optimized geometric design that improved the bone fit, it is not necessary to use specialized, detailed preoperative planning, except in challenging anatomical conditions; e.g., in young children, malformations, poor pneumatization, or after a canal wall down mastoidectomy.


Assuntos
Condução Óssea , Auxiliares de Audição , Perda Auditiva Condutiva-Neurossensorial Mista , Criança , Pré-Escolar , Perda Auditiva Condutiva , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Humanos , Próteses e Implantes , Resultado do Tratamento
3.
Rheumatol Int ; 40(11): 1771-1779, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32488430

RESUMO

Rheumatoid arthritis (RA) is a systemic autoimmune disease affecting up to 1% of the worldwide population. RA is associated with multiple extra-articular manifestations (EAMs). Middle ear, cochlea and the auditory nerve are suspected sites of RA activity and hearing loss is a possible novel EAM of RA. Objective was to investigate the association of RA with the different subtypes of hearing loss. This systematic review was performed according to the PRISMA guidelines. A random effects model meta-analysis was conducted and the I2 was used to assess heterogeneity. Twelve studies comprising 20,022 RA patients and 79,244 controls were included in this systematic review. All studies were observational and were rated to a moderate rate of bias. RA patients had nearly fourfold increased odds of sensorineural hearing loss (SNHL) compared with controls (OR 3.42; 95% CI 2.50-4.69; I2 = 13). RA patients also had a significantly increased risk of SNHL (RR 2.28; 95% CI 1.88-2.76; I2 = 0). RA patients did not have increased odds of conductive hearing loss (CHL) and mixed hearing loss (MHL) (OR 1.36; 95% CI 0.52-3.55; I2 = 22); (OR 2.73; 95% CI 0.78-9.58; I2 = 0%). RA is significantly associated with SNHL. RA is not associated with CHL and MHL. Early screening of RA patients with pure tone audiometry should be considered.


Assuntos
Artrite Reumatoide/epidemiologia , Perda Auditiva Condutiva/epidemiologia , Perda Auditiva Condutiva-Neurossensorial Mista/epidemiologia , Perda Auditiva Neurossensorial/epidemiologia , Audiometria de Tons Puros , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Perda Auditiva Neurossensorial/diagnóstico , Humanos , Programas de Rastreamento , Razão de Chances
4.
Eur Arch Otorhinolaryngol ; 277(3): 715-725, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31811384

RESUMO

INTRODUCTION: The BAHA (bone-anchored hearing aid) Attract is a magnetic transcutaneous bone conduction device anchored into the temporal bone. The standard surgical technique for BAHA Attract is a multi-tools time-consuming process, which requires a large cutaneous incision. The objective of this study is to describe and test the feasibility of a minimally invasive pocket (MIP) technique for Magnet Bone Implant Hearing Aid (MBIHA) with a modified magnet of BAHA Attract without fixation and without any tissue reduction. We use a 3-cm vertical skin incision and a subperiosteal pocket. METHOD: A study of 10 patients with conductive or mixed hearing loss who benefited from a MBIHA using the MIP technique is presented. The pure tone average (PTA) (dB) for air-conduction thresholds and the speech recognition threshold (SRT) (dB) in speech audiometry in quiet are calculated. The Entific Medical Systems (EMS) questionnaire and the postoperative clinical outcomes are realized. RESULTS: We found a significant improvement of 33.8 dB on average for the PTA and 44.8 dB for the SRT with MBIHA at 3 months, compared with unaided situation. No implant was removed or displaced after 2 years of follow-up. The skin condition remains intact in all the cases. CONCLUSION: The minimally subperiosteal pocket surgical technique MIP without fixation and with tissue preservation for the MBIHA is safe, rapid and effective for patients with conductive or mixed hearing loss. It opens new perspectives of development and modify conventional concept in magnetic coupling of bone-conducted device.


Assuntos
Prótese Ancorada no Osso , Auxiliares de Audição , Perda Auditiva Condutiva/cirurgia , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Implantação de Prótese/métodos , Adolescente , Adulto , Percepção Auditiva , Criança , Estudos de Viabilidade , Feminino , Perda Auditiva Bilateral/diagnóstico , Perda Auditiva Bilateral/fisiopatologia , Perda Auditiva Bilateral/cirurgia , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/fisiopatologia , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/fisiopatologia , Perda Auditiva Unilateral/diagnóstico , Perda Auditiva Unilateral/fisiopatologia , Perda Auditiva Unilateral/cirurgia , Humanos , Imãs , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Implantação de Prótese/instrumentação , Retalhos Cirúrgicos , Resultado do Tratamento , Adulto Jovem
5.
Ann Otol Rhinol Laryngol ; 129(3): 216-223, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31631685

RESUMO

OBJECTIVES: To compare preoperative temporal bone high-resolution computed tomography (HRCT) readings to intraoperative findings during exploratory tympanotomy for suspected cases of isolated congenital middle ear malformations (CMEMs) and summarize the malformations that can and cannot be diagnosed with HRCT. METHODS: A retrospective study was conducted. All cases were confirmed as isolated CMEMs during surgery. Detailed clinical records were reviewed, with a focus on imaging and surgical findings. RESULTS: One hundred and thirty-two patients and 145 ears were reviewed. Ninety cases (62.1%) could be identified as isolated CMEMs and at least one as middle ear anomaly using preoperative HRCT. Fifty-five cases (37.9%) were reported to be completely normal and the patients underwent exploratory tympanotomy to determine the final diagnosis. Stapes fixation, either alone or associated with other ossicular chain anomalies, contributed to 53.1% of the cases. Most cases of aplasia or dysplasia of the ossicular chain, for example, aplasia/dysplasia of the long process of the incus, aplasia of the stapes' superstructure, and atresia of the oval window were easily identified in preoperative HRCT. However, fixation of the ossicular chain can be elusive in HRCT, and exploratory tympanotomy is needed for a definitive diagnosis. CONCLUSIONS: HRCT provides helpful preoperative clinical information in CMEM and may obviate the need for middle ear exploration in some cases. The negative findings (anomalies that are difficult to identify through preoperative HRCT) and the positive findings (anomalies that are relatively easy to identify through preoperative HRCT) were summarized.


Assuntos
Orelha Média/anormalidades , Janela do Vestíbulo/anormalidades , Adolescente , Adulto , Criança , Pré-Escolar , Anormalidades Congênitas/diagnóstico , Orelha Média/diagnóstico por imagem , Orelha Média/patologia , Feminino , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Janela do Vestíbulo/diagnóstico por imagem , Janela do Vestíbulo/patologia , Cuidados Pré-Operatórios , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
6.
Eur Arch Otorhinolaryngol ; 277(1): 55-60, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31570983

RESUMO

PURPOSE: The primary objective of the retrospective study was to collect speech intelligibility data on children and adolescents implanted with the vibrating ossicular prosthesis (VORP) 503. METHODS: This was a retrospective, multicentre study on 55 children and adolescents from 6 German clinics aged between 5 and 17 years suffering from mixed or conductive hearing loss implanted with a VORP 503. Pre- and postoperative bone-conduction pure tone thresholds were measured at 0.5, 1, 2 and 4 kHz, and word recognition scores in the unaided and VORP 503-aided conditions using monosyllabic speech intelligibility tests measured at 65-dB sound pressure level (SPL) were determined. RESULTS: Mean pre- and postoperative bone-conduction thresholds remained unchanged, showing the preservation of inner ear hearing. Speech intelligibility assessed in quiet at 65-dB SPL improved on average from 24.5% (SD ± 25.4) unaided to 86.4% (SD ± 13.4) aided. The average improvement of 61.9% (SD ± 25.3) was clinically and statistically significant. A total of three complications were found in the medical records of 55 subjects. The responsible investigators judged these events as procedure related. CONCLUSION: The treatment of children suffering from conductive or mixed hearing loss with the VORP 503 implant demonstrates excellent aided benefit in terms of speech understanding and only minor complications.


Assuntos
Perda Auditiva Condutiva/cirurgia , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Prótese Ossicular , Adolescente , Limiar Auditivo , Condução Óssea/fisiologia , Criança , Pré-Escolar , Feminino , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/fisiopatologia , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/fisiopatologia , Testes Auditivos , Humanos , Estudos Longitudinais , Masculino , Estudos Retrospectivos , Inteligibilidade da Fala , Resultado do Tratamento , Vibração
7.
Ann Otol Rhinol Laryngol ; 128(6): 485-489, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30781969

RESUMO

OBJECTIVE: To identify and characterize hearing loss (HL) in children with septo-optic dysplasia (SOD). METHODS: Otologic and audiometric data for patients less than 18 years of age identified as having SOD who were seen in the Children's Healthcare of Atlanta-Scottish Rite Hospital clinic between 2013 and 2017 were collected and reviewed through a HIPAA-compliant medical record search. Relevant literature was also reviewed with the assistance of Medline. RESULTS: Sixty-four patients with SOD were identified, and 7 of those patients (10.9%) were diagnosed with hearing loss. Type of hearing loss was sensorineural (SNHL) in 5 patients (63%), mixed (MHL) in 1(14%), and conductive (CHL) in 1(14%). Bilateral loss presented in 60% (3/5) of SNHL patients, while the rest demonstrated unilateral loss. Unilateral findings included cochlear nerve deficiency (1) and atresia/microtia (1). Tympanostomy tubes were required in 57% (4/7) of SOD children with hearing loss. Amplification was successfully implemented in 86% (6/7). CONCLUSIONS: Hearing loss was found in nearly 11% of SOD children, and SNHL was identified as (63%) the predominant form of loss. To our knowledge, this is the first retrospective review of hearing loss in a pediatric SOD cohort and the first to report of cochlear nerve deficiency and atresia/microtia in this population. Based on these findings, early identification of hearing loss with imaging when appropriate and treatment of otitis in this population is recommended.


Assuntos
Perda Auditiva/diagnóstico , Perda Auditiva/etiologia , Displasia Septo-Óptica/complicações , Testes de Impedância Acústica , Criança , Pré-Escolar , Doença Crônica , Feminino , Perda Auditiva Bilateral/diagnóstico , Perda Auditiva Bilateral/etiologia , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/etiologia , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/etiologia , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/etiologia , Perda Auditiva Unilateral/diagnóstico , Perda Auditiva Unilateral/etiologia , Humanos , Lactente , Imageamento por Ressonância Magnética , Masculino , Ventilação da Orelha Média , Otite Média/etiologia , Otite Média/terapia , Estudos Retrospectivos , Displasia Septo-Óptica/diagnóstico por imagem
8.
Vestn Otorinolaringol ; 83(3): 65-68, 2018.
Artigo em Russo | MEDLINE | ID: mdl-29953059

RESUMO

This article was designed to report a clinical case of an acute acoustic injury inflicted by a discharge of the lightning ball during the early postoperative period in a female patient following surgical stapedoplasty. The acoustic impact resulted in a marked deterioration of hearing in the operated ear with simultaneous elevation of the threshold of bone sound conduction to above the preoperative value. It is concluded that the patients who had undergone the stapedoplastic surgical intervention should be advised to avoid strong acoustic impacts during the postoperative period.


Assuntos
Perda Auditiva Condutiva-Neurossensorial Mista , Perda Auditiva Provocada por Ruído/complicações , Otosclerose , Complicações Pós-Operatórias , Cirurgia do Estribo , Adulto , Audiometria/métodos , Tratamento Conservador/métodos , Feminino , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/fisiopatologia , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Humanos , Otosclerose/diagnóstico , Otosclerose/fisiopatologia , Otosclerose/cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Período Pós-Operatório , Cirurgia do Estribo/efeitos adversos , Cirurgia do Estribo/métodos , Resultado do Tratamento
9.
Acta Derm Venereol ; 98(7): 655-659, 2018 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-29648672

RESUMO

Psoriasis is a systemic inflammatory disorder associated with many other chronic and progressive diseases. There are few studies on the association of psoriasis with alterations in auditory function. A clinical and instrumental pilot study of auditory function was performed with 77 psoriatic patients and 77 age- and sex-matched healthy controls. The main results were: (i) hearing loss, mostly of sensorineural type, was significantly more frequent in patients than in controls; (ii) conductive and mixed hearing loss were more frequent in arthropathic than in non-arthropathic psoriatic patients; (iii) duration of psoriasis > 10 years or smoking were associated with higher frequency of hearing loss; (iv) psoriasis was more severe in patients with hearing loss than in those without hearing loss. Tympanogram abnormalities were found in patients more often than in controls. These data expand the list of extracutaneous conditions associated with psoriasis, and support the need for further basic and clinical research in this field.


Assuntos
Vias Auditivas/fisiopatologia , Perda Auditiva Condutiva/etiologia , Perda Auditiva Condutiva-Neurossensorial Mista/etiologia , Perda Auditiva Neurossensorial/etiologia , Audição , Psoríase/complicações , Adulto , Idoso , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Feminino , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/fisiopatologia , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/fisiopatologia , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/fisiopatologia , Testes Auditivos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Projetos Piloto , Psoríase/diagnóstico , Fatores de Risco , Adulto Jovem
10.
Audiol Neurootol ; 23(6): 316-325, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30650421

RESUMO

OBJECTIVE: To evaluate the long-term safety and performance of four different vibroplasty couplers (round window, oval window, CliP and Bell coupler) in combination with an active middle ear implant. METHODS: This was a multicentre, prospective, long-term study including 5 German hospitals. Thirty adult subjects suffering from conductive or mixed hearing loss were initially enrolled for the study, 24 of these were included in the final analysis with up to 36 months of postsurgical follow-up data. Bone conduction and air conduction were measured pre- and postoperatively to evalu ate safety. Postoperative aided sound field thresholds and Freiburger monosyllable word recognition scores were compared to unaided pre-implantation results to confirm performance. Additional speech tests compared postoperative unaided with aided results. To determine patient satisfaction, an established quality-of-life questionnaire developed for conventional hearing aid usage was administered to all subjects. RESULTS: Mean postoperative bone conduction thresholds remained stable throughout the whole study period. Mean functional gain for all couplers investigated was 38.5 ± 11.4 dB HL (12 months) and 38.8 ± 12.5 dB HL (36 months). Mean word recognition scores at 65 dB SPL increased from 2.9% in the unaided by 64.2% to 67.1% in the aided situation. The mean postoperative speech reception in quiet (or 50% understanding of words in sentences) shows a speech intelligibility improvement at 36 months of 17.8 ± 12.4 dB SPL over the unaided condition. The signal-to-noise ratio (SNR) improved by 5.9 ± 7.2 dB SNR over the unaided condition. High subjective device satisfaction was reflected by the International Inventory for Hearing Aids scored very positively. CONCLUSION: A significant improvement was seen with all couplers, and audiological performance did not significantly differ between 12 and 36 months after surgery.


Assuntos
Perda Auditiva Condutiva/reabilitação , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Prótese Ossicular , Desenho de Prótese , Adulto , Idoso , Audiometria de Tons Puros , Limiar Auditivo , Feminino , Seguimentos , Alemanha , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Substituição Ossicular/reabilitação , Satisfação do Paciente , Estudos Prospectivos
11.
Eur Arch Otorhinolaryngol ; 274(8): 3011-3019, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28534117

RESUMO

Examination of objective as well as subjective outcomes with a new transcutaneous bone-anchored hearing aid device. The study was designed as a prospective multicenter consecutive case-series study involving tertiary referral centers at two Danish University Hospitals. A total of 23 patients were implanted. Three were lost to follow-up. Patients had single-sided deafness, conductive or mixed hearing loss. INTERVENTION: Rehabilitative. Aided and unaided sound field hearing was evaluated objectively using (1) pure warble tone thresholds, (2) pure-tone average (PTA4), (3) speech discrimination score (SDS) in quiet, and (4) speech reception threshold 50% at 70 dB SPL noise level (SRT50%). Subjective benefit was evaluated by three validated questionnaires: (1) the IOI-HA, (2) the SSQ-12, and (3) a questionnaire evaluating both the frequency and the duration of hearing aid usage. The mean aided PTA4 was lowered by 14.7 dB. SDS was increased by 37.5% at 50 dB SPL, SRT50% in noise improved 1.4 dB. Aided thresholds improved insignificantly at frequencies above 2 kHz. 52.9% of the patients used their device every day, and 76.5% used the device at least 5 days a week. Mean IOI-HA score was 3.4, corresponding to a good benefit. In SSQ-12, "quality of hearing" scored especially high. Patients with a conductive and/or mixed hearing loss benefitted the most. This device demonstrates a significant subjective hearing benefit 8 month post surgery. In patients with conductive and/or mixed hearing losses, patient satisfaction and frequency of use were high. Objective gain measures showed less promising results especially in patients with single-sided deafness (SSD) compared to other bone conduction devices.


Assuntos
Auxiliares de Audição , Perda Auditiva Condutiva , Perda Auditiva Condutiva-Neurossensorial Mista , Satisfação do Paciente/estatística & dados numéricos , Adulto , Idoso , Dinamarca , Feminino , Auxiliares de Audição/psicologia , Auxiliares de Audição/estatística & dados numéricos , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/psicologia , Perda Auditiva Condutiva/terapia , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/psicologia , Perda Auditiva Condutiva-Neurossensorial Mista/terapia , Testes Auditivos/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Estudos Prospectivos , Inquéritos e Questionários
12.
J Otolaryngol Head Neck Surg ; 46(1): 2, 2017 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-28057076

RESUMO

BACKGROUND: Tensor tympani contraction may have a "signature" audiogram. This study demonstrates audiometric findings during voluntary tensor tympani contraction. METHODS: Five volunteers possessing the ability to voluntarily contract their tensor tympani muscles were identified and enrolled. Tensor tympani contraction was confirmed with characteristic tympanometry findings. Study subjects underwent conventional audiometry. Air conduction and bone conduction threshold testing was performed with and without voluntary tensor tympani contraction. MAIN OUTCOME MEASURE: Changes in air conduction and bone conduction thresholds during voluntary tensor tympani contraction. RESULTS: Audiometric results demonstrate a low frequency mixed hearing loss resulting from tensor tympani contraction. Specifically, at 250 Hz, air conduction thresholds increased by 22 dB and bone conduction thresholds increased by 10 dB. CONCLUSIONS: Previous research has demonstrated a low frequency conductive hearing loss in the setting of tensor tympanic contraction. This is the first study to demonstrate a low frequency mixed hearing loss associated with tensor tympani contraction. This finding may aid in the diagnosis of disorders resulting from abnormal tensor tympani function. Tensor tympani contraction should be included on the differential for low frequency mixed hearing loss.


Assuntos
Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Contração Muscular/fisiologia , Tensor de Tímpano/fisiologia , Testes de Impedância Acústica , Audiometria , Limiar Auditivo/fisiologia , Condução Óssea/fisiologia , Perda Auditiva Condutiva-Neurossensorial Mista/etiologia , Humanos
13.
J Int Adv Otol ; 12(3): 241-246, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28031155

RESUMO

OBJECTIVE: To demonstrate the surgical technique and audiological results of a middle ear implant for restoring hearing in patients with bilateral aural atresia and microtia with conductive or mixed hearing loss. MATERIALS AND METHODS: In this prospective study, 12 subjects aged 12 years and older presenting with hearing loss and bilateral congenital aural atresia underwent surgical insertion of a middle ear implant. The patients underwent tympanomastoidectomy with a wide opening of the attic and preservation of the roof of the atresic tympanic bone to expose the middle ear and position the floating mass transducer of the implant. RESULTS: There were no intraoperative or postoperative complications. The hearing threshold averages in a free field were 53.5 dB preoperatively and 25.6 dB postoperatively. Monosyllabic word recognition averaged 61% preoperatively and 91.3% postoperatively. The average speech perception in quiet conditions during the hearing in noise test improved from 67.11 dB to 45.99 dB, and the signal-to-noise ratio improved from 5.64 to 1.31. CONCLUSION: The tested system is an excellent option for auditory rehabilitation of conductive hearing loss due to bilateral ear atresia. The surgery is well structured and safe and provides several alternatives to the surgeon, which is valuable in difficult cases.


Assuntos
Anormalidades Congênitas/cirurgia , Microtia Congênita/complicações , Orelha/anormalidades , Perda Auditiva Condutiva/reabilitação , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Prótese Ossicular , Substituição Ossicular , Adolescente , Adulto , Anormalidades Congênitas/reabilitação , Microtia Congênita/cirurgia , Orelha/cirurgia , Feminino , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/etiologia , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/etiologia , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
14.
Int J Pediatr Otorhinolaryngol ; 90: 251-258, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27729144

RESUMO

OBJECTIVE: To provide recommendations for the workup of hearing loss in the pediatric patient. METHODS: Expert opinion by the members of the International Pediatric Otolaryngology Group. RESULTS: Consensus recommendations include initial screening and diagnosis as well as the workup of sensorineural, conductive and mixed hearing loss in children. The consensus statement discusses the role of genetic testing and imaging and provides algorithms to guide the workup of children with hearing loss. CONCLUSION: The workup of children with hearing loss can be guided by the recommendations provided herein.


Assuntos
Perda Auditiva Central/diagnóstico , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Perda Auditiva Neurossensorial/diagnóstico , Criança , Pré-Escolar , Surdez/diagnóstico , Surdez/genética , Testes Genéticos , Perda Auditiva/diagnóstico , Perda Auditiva/genética , Perda Auditiva Central/genética , Perda Auditiva Condutiva/genética , Perda Auditiva Condutiva-Neurossensorial Mista/genética , Perda Auditiva Neurossensorial/genética , Humanos , Lactente , Recém-Nascido , Masculino , Programas de Rastreamento , Triagem Neonatal , Emissões Otoacústicas Espontâneas , Otolaringologia/normas , Pediatria/normas
16.
Artigo em Inglês | MEDLINE | ID: mdl-25661010

RESUMO

OBJECTIVE: To describe our experience with positioning the Bonebridge (BB) device, a semi-implantable transcutaneous bone conduction implant for patients with conductive and mixed hearing loss as well as for those suffering from single-sided deafness. METHODS: The following is a retrospective case review of 4 adults suffering from conductive or mixed hearing loss and single-sided deafness. The BB device was implanted unilaterally via 2 different approaches selected case by case: the presigmoid transmastoid and the retrosigmoid approach. An audiological evaluation in the free field was conducted to observe the functional benefit with this device. The Glasgow Health Status Inventory (GHSI) and the Glasgow Benefit Inventory (GBI) questionnaires were filled out to evaluate patients' quality of life in relationship to the intervention. RESULTS: No intra- or postoperative complications were observed. The performance in the speech test in all 4 cases reached 100% in the aided condition at 65 dB, while in the unaided condition at 65 dB, it was less than 10%. The GHSI and GBI questionnaires showed an improvement in quality of life after implantation. CONCLUSIONS: The BB device is a safe and effective solution for individuals with pathologies such as chronic otitis media, atresia auris and otosclerosis with inadequate benefit from conventional surgery or bone conduction hearing aids.


Assuntos
Auxiliares de Audição , Perda Auditiva Condutiva/terapia , Perda Auditiva Condutiva-Neurossensorial Mista/terapia , Adulto , Idoso , Audiometria , Condução Óssea , Feminino , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/etiologia , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Estudos Retrospectivos , Percepção da Fala , Resultado do Tratamento
17.
Eur Arch Otorhinolaryngol ; 272(12): 3705-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25534285

RESUMO

Turner syndrome (TS) is one of the most frequently encountered sex-linked chromosomal abnormalities, occurring in one per 2,000 female births. These patients present with short stature and failure to begin puberty. In this syndrome, there are multiple organ abnormalities, including auditory disorders. TS patients were referred to the ENT clinic by a pediatric endocrinologist. A questionnaire was filled out and the patients went through a complete otologic examination. They were then referred to the audiology clinic to undergo audiologic test battery plus high-frequency pure tone audiometry. From a total of 48 ears examined, 11 (22.9 %) had a normal audiometry. Mid-frequency sensorineural hearing loss (SNHL), high-frequency SNHL, combined and mixed hearing loss were diagnosed in 6 (12/5 %), 20 (41/7 %), 6 (12/5 %) and 1 (2/1 %) ear, respectively. Tympanogram results showed normal compliance (A, As, Ad) in the majority of cases. B and C patterns were found in a few cases. Speech discrimination score was normal in all patients whereas speech reception threshold was normal in 92 % of the ears. Audiometry abnormality especially SNHL is common in TS patients, with the high-frequency pattern being the most frequent.


Assuntos
Perda Auditiva de Alta Frequência/etiologia , Perda Auditiva Condutiva-Neurossensorial Mista/etiologia , Perda Auditiva Neurossensorial/etiologia , Síndrome de Turner/complicações , Adolescente , Adulto , Audiometria de Tons Puros , Criança , Pré-Escolar , Feminino , Perda Auditiva de Alta Frequência/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Perda Auditiva Neurossensorial/diagnóstico , Humanos , Irã (Geográfico) , Adulto Jovem
18.
Eur Arch Otorhinolaryngol ; 272(9): 2261-6, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25012703

RESUMO

Cochlear implantation is associated with deterioration in hearing. Despite the fact that the damage is presumed to be of sensory origin, residual hearing is usually assessed by air-conduction thresholds alone. This study sought to determine if surgery may cause changes in air- and bone-conduction thresholds producing a mixed-type hearing loss. The sample included 18 patients (mean age 37 years) with an air-bone gap of 10 dB over three consecutive frequencies and measurable masked and reliable bone-conduction thresholds of operated and non-operated ears who underwent cochlear implant surgery. All underwent comprehensive audiologic and otologic assessment and imaging before and after surgery. The air-bone gap in the treated ears was 17-41 dB preoperatively and 13-59 dB postoperatively over 250-4,000 Hz. Air-conduction thresholds in the treated ears significantly deteriorated after surgery, by a mean of 10-21 dB. Bone-conduction levels deteriorated nonsignificantly by 0.8-7.5 dB. The findings indicate that the increase in air-conduction threshold after cochlear implantation accounts for most of the postoperative increase in the air-bone gap. Changes in the mechanics of the inner ear may play an important role. Further studies in larger samples including objective measures of inner ear mechanics may add information on the source of the air-bone gap.


Assuntos
Implante Coclear/efeitos adversos , Perda Auditiva Condutiva-Neurossensorial Mista/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Condução Óssea , Criança , Pré-Escolar , Implantes Cocleares , Feminino , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
19.
Neuroradiol J ; 27(4): 479-81, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25196623

RESUMO

We describe the case of a 39-year-old man in whom diagnostic work-up for combined right-sided hearing loss revealed a lipoma of the internal auditory canal (IAC). This very rare diagnosis has significant implications for therapeutic management because lipomas, unlike other lesions in the IAC, should not be surgically removed in most cases. We emphasize the importance of the combined use of magnetic resonance imaging and computed tomography to reliably establish the diagnosis of a lipoma, differentiate it from other potential lesions of the internal auditory canal, and exclude additional pathologies in the petrosal bone.


Assuntos
Meato Acústico Externo/diagnóstico por imagem , Neoplasias da Orelha/diagnóstico por imagem , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Lipoma/diagnóstico por imagem , Adulto , Audiometria de Tons Puros , Perda Auditiva Condutiva-Neurossensorial Mista/etiologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Tomografia Computadorizada por Raios X
20.
Eur Arch Otorhinolaryngol ; 271(5): 1339-43, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24504491

RESUMO

Hearing is of utmost importance for normal speech and social development. Even children who have mild or unilateral permanent hearing loss may experience difficulties with understanding speech, as well as problems with educational and psycho-social development. The increasing advantages of middle-ear implant technologies are opening new perspectives for restoring hearing. Active middle-ear implants can be used in children and adolescents with hearing loss. In addition to the well-documented results for improving speech intelligibility and quality of hearing in sensorineural hearing loss active middle-ear implants are now successfully used in patients with conductive and mixed hearing loss. In this article we present a case of successful, single-stage vibroplasty, on the right side with the fixation of the FMT on the stapes and PORP CLiP vibroplasty on the left side in a 6-year-old girl with bilateral mixed hearing loss and multiple dyslalia associated with Franceschetti syndrome (mandibulofacial dysostosis). CT revealed bilateral middle-ear malformations as well as an atretic right and stenotic left external auditory canal. Due to craniofacial dysmorphia airway and (post)operative, management is significantly more difficult in patients with a Franceschetti syndrome which in this case favoured a single-stage bilateral procedure. No intra- or postoperative surgical complications were reported. The middle-ear implants were activated 4 weeks after surgery. In the audiological examination 6 months after surgery, the child showed 100% speech intelligibility with activated implants on each side.


Assuntos
Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Disostose Mandibulofacial/reabilitação , Prótese Ossicular , Audiometria da Fala , Limiar Auditivo/fisiologia , Criança , Feminino , Seguimentos , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Humanos , Transtornos do Desenvolvimento da Linguagem/diagnóstico , Transtornos do Desenvolvimento da Linguagem/reabilitação , Disostose Mandibulofacial/diagnóstico , Desenho de Prótese , Teste do Limiar de Recepção da Fala , Tomografia Computadorizada por Raios X , Vibração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA