Resultados 1 - 20 de 46
Filtrar
1.
Ann Agric Environ Med ; 31(2): 287-293, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38940114

RESUMO

INTRODUCTION AND OBJECTIVE: Ultraviolet light in the UV-C band is known as germicidal radiation and was widely used for both sterilization of the equipment and creation of a sterile environment. The aim of the study is to assess the effectiveness of inactivation of microorganisms deposited on surfaces with various textures by UV-C radiation disinfection devices. MATERIAL AND METHODS: Five microorganisms (3 bacteria, virus, and fungus) deposited on metal, plastic, and glass surfaces with smooth and rough textures were irradiated with UV-C light emitted by low-pressure mercury lamp and ultraviolet emitting diodes (LEDs), from a distance of 0.5 m, 1 m, and 1.5 m to check their survivability after 20-minute exposure. RESULTS AND CONCLUSIONS: Both tested UV-C sources were effective in inactivation of microorganisms; however, LED emitter was more efficient in this respect than the mercury lamp. The survival rate of microorganisms depended on the UV-C dose, conditioned by the distance from UV-C source being the highest at 0.5 m and the lowest at 1.5 m. For the tested microorganisms, the highest survival rate after UV-C irradiation was usually visible on glass and plastic surfaces. This observation should be considered in all environments where the type of material (from which the elements of technical equipment are manufactured and may be contaminated by specific activities) is important for maintaining the proper level of hygiene and avoiding the unwanted and uncontrolled spread of microbiological pollution.


Assuntos
Bactérias , Desinfecção , Fungos , Raios Ultravioleta , Desinfecção/métodos , Desinfecção/instrumentação , Fungos/efeitos da radiação , Bactérias/efeitos da radiação , Bactérias/isolamento & purificação , Vírus/efeitos da radiação , Propriedades de Superfície , Viabilidade Microbiana/efeitos da radiação , Plásticos/efeitos da radiação , Plásticos/química , Vidro/química
2.
Mar Pollut Bull ; 140: 274-280, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30803643

RESUMO

Plastics in the ocean are of great concern nowadays, and are often referred to as the apocalyptic twin of climate change in terms of public fear and the problems they pose to the aquatic and terrestrial environment. The number of studies focusing on the ecological effects and toxicity of plastics has substantially increased in the last few years. Considering the current trends in the anthropogenic activities, the amount of plastics entering the world oceans is increasing exponentially, but the oceans have a low assimilative capacity for plastics and the near-surface layer of it is a finite space. If loading of the oceans with plastics continues at the current rate, the thin sea surface microlayer can have a substantial amount of plastics comparable to the distribution of phytoplankton, at least in the major oceanic gyres and coastal waters in the future. Also, processes like biofouling can cluster microplastics in dense fields in the near-surface layer. Plastics can contribute to the warming or cooling of the water column by scattering and attenuating incoming solar radiation, leading to a potential change in the optical and other physico-chemical properties of the water column. We propose a new notion that changes in solar radiation in the water column due to the plastics have the potential to affect the physical processes in the ocean surface and near-surface layers, and can induce climate feedback cycles. The future can be very different, if plastics evolve as one of the key players affecting the ocean physical processes and hence this is the time to tackle this puzzle with appropriate strategies or let the genie out of the bottle.


Assuntos
Mudança Climática , Conservação dos Recursos Hídricos/tendências , Plásticos/análise , Água do Mar , Poluentes Químicos da Água/análise , Incrustação Biológica/prevenção & controle , Ecossistema , Oceanos e Mares , Fitoplâncton/crescimento & desenvolvimento , Plásticos/efeitos da radiação , Água do Mar/química , Água do Mar/microbiologia , Poluentes Químicos da Água/efeitos da radiação
3.
Environ Pollut ; 245: 1031-1040, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30682737

RESUMO

Storm water culverts are integral for U.S. public safety and welfare, and their mechanical failure can cause roadways to collapse. To repair these buried assets, ultraviolet (UV) light cured-in-place-pipes (CIPP) are being installed. Chemical emission and residual material left behind from the installation process was investigated in New York and Virginia, USA. Samples of an uncured resin tube and field-cured styrene-based resin CIPPs were collected and analyzed. Also collected were air and water samples before, during, and after installations. Chemicals were emitted into air because of the installation and curing processes. Particulates emitted into the air, water, and soil contained fiberglass, polymer, and contaminants, some of which are regulated by state-level water quality standards. The uncured resin tube contained more than 70 chemical compounds, and 19 were confirmed with analytical standards. Compounds included known and suspected carcinogens, endocrine disrupting compounds, hazardous air pollutants, and other compounds with little aquatic toxicity data available. Compounds (14 of 19 confirmed) were extracted from the newly installed CIPPs, and 11 were found in water samples. Aqueous styrene (2.31 mg/L), dibutyl phthalate (12.5 µg/L), and phenol (16.7 µg/L) levels exceeded the most stringent state water quality standards chosen in this study. Styrene was the only compound that was found to have exceed a 48 h aquatic toxicity threshold. Newly installed CIPPs contained a significant amount volatile material (1.0 to > 9.0 wt%). Recommendations provided can reduce chemical emission, as well as improve worksite and environmental protection practices. Recommended future research is also described.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/métodos , Plásticos/química , Raios Ultravioleta , Poluentes Químicos da Água/análise , Água/química , Vidro/química , Vidro/efeitos da radiação , New York , Plásticos/efeitos da radiação , Estireno/química , Estireno/efeitos da radiação , Virginia
4.
Environ Int ; 121(Pt 1): 942-954, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30352377

RESUMO

Plastic debris is an emerging worldwide threat to marine biota. Marine species may face unique challenges in low-flow estuarine systems with a high abundance of "macro-sized" (>4.75 mm) plastic due to the leaching of constituents and adsorbed contaminants. To simulate this leaching process, plastic samples recovered from the North Pacific Gyre along with corresponding UV-irradiated virgin plastic and non-irradiated virgin plastic counterparts were incubated in saltwater for 30 days at ambient temperatures ranging from 17 to 25 °C. Following solid-phase extraction, water samples were fractionated with sequential methanol elution from 10 to 100% and evaluated using in vitro assays assessing estrogen receptor (ER) and aryl hydrocarbon receptor (AhR) activities. In vivo responses (vitellogenin [vtg] and cytochrome p450 1A [cyp1a] mRNA) were measured following 5-day exposures in Japanese medaka (Oryzias latipes) larvae (3 days post hatch). Estrogenic plasticizers, co-planar PCBs and PAHs were quantified in the extracts using targeted GC-MS/MS and UPLC-MS/MS. In vitro estrogenicity showed highest activity in the 70% methanol fraction for all plastic leachate exposures. Whole extract in vitro estradiol equivalent (EEQ) values were 4.34 ±â€¯2.65, 8.79 ±â€¯2.09 and 13.78 ±â€¯3.64 ng/L, for virgin plastic, UV-irradiated virgin plastic and North Pacific Gyre-recovered plastic, respectively (mean ±â€¯SD). Significant vtg induction was observed in medaka larvae exposed to leachate extracts from North Pacific Gyre-recovered plastic and UV-irradiated virgin plastic (9.9-fold, p = 0.039 and 10.1-fold, p = 0.042, respectively). Chemically-determined EEQ values were also localized in the 70% methanol fraction. Whole leachate extract chemical EEQ values were 0.33 ±â€¯0.07, 1.64 ±â€¯0.62 and 11.4 ±â€¯2.13 ng/L, for virgin plastic, UV-irradiated virgin plastic and North Pacific Gyre-recovered plastic, respectively. In-vitro AhR activity was highest in the 70% methanol elution with greater activity in North Pacific Gyre-recovered plastic than in virgin plastic and UV-irradiated virgin plastic (toxic equivalency [TEQ] = 1.06 ±â€¯0.54, 0.38 ±â€¯0.07 and 0.71 ±â€¯0.47 ng/L, respectively). CYP1A mRNA was significantly induced in larval medaka exposed to North Pacific Gyre-recovered plastic leachates (17.8-fold, p = 0.02) while exposure to virgin plastic and UV-irradiated virgin plastic leachates caused no significant change. Chemically-determined TEQ analysis for AhR indicated highest activity in the 90% methanol fraction for all leachates, with whole extract in vitro TEQs being 1.47 ±â€¯0.87, 0.03 ±â€¯0.05 and 0.42 ±â€¯0.38 ng/L for North Pacific Gyre-recovered plastic, virgin plastic and UV-irradiated virgin plastic, respectively. These results indicate that weathering and UV radiation release estrogenic plasticizers and demonstrate the ability for plastics to transport adsorbed persistent organic pollutants at eco-toxicologically relevant concentrations.


Assuntos
Plásticos/análise , Plásticos/efeitos da radiação , Raios Ultravioleta , Poluentes Químicos da Água/análise , Animais , Cromatografia Líquida , Estradiol/análise , Oryzias/metabolismo , Bifenilos Policlorados/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Receptores de Hidrocarboneto Arílico/metabolismo , Receptores de Estrogênio/metabolismo , Água do Mar , Espectrometria de Massas em Tandem , Vitelogeninas/metabolismo
5.
Artigo em Inglês | MEDLINE | ID: mdl-27043734

RESUMO

After the prohibition of bisphenol-A-containing polycarbonate baby bottles in the European Union (EU), alternative materials, such as polypropylene, polyethersulphone, Tritan™ copolyester, etc., have appeared on the market. Based on an initial screening and in vitro toxicity assessment, the most toxic migrating compounds were selected to be monitored and quantified using validated GC- and LC-QqQ-MS methods. The effect of several 'real-life-use conditions', such as microwave, sterilisation and dishwasher, on the migration of different contaminants was evaluated by means of duration tests. These results were compared with a reference treatment (filling five times with pre-heated simulant at 40°C) and with the legal EU 'repetitive-use conditions' (three migrations, 2 h at 70°C). Analysis of the third migration step of the EU repetitive-use conditions (which has to comply with the EU legislative migration limits) showed that several non-authorised compounds were observed in some baby bottles exceeding 10 µg kg(-1). However, all authorised compounds were detected well below their respective specific migration limits (SMLs). The reference experiment confirmed the migration of some of the compounds previously detected in the EU repetitive-use experiment, though at lower concentrations. Analysis of extracts from the microwave and dishwasher experiments showed a reduction in the migration during the duration tests. In general, the concentrations found were low and comparable with the reference experiment. Similar observations were made for the two sterilisation types: steam and cooking sterilisation. However, steam sterilisation seems to be more recommended for daily use of baby bottles, since it resulted in a lower release of substances afterwards. Repeated use of baby bottles under 'real-life' conditions showed no increase in the migration of investigated compounds and, after some time, the migration of these compounds even became negligible.


Assuntos
Alimentação com Mamadeira/instrumentação , Contaminação de Alimentos/prevenção & controle , Teste de Materiais/métodos , Leite/química , Plastificantes/análise , Plásticos/química , Animais , Bélgica , Alimentação com Mamadeira/efeitos adversos , Detergentes/efeitos adversos , Detergentes/química , Difusão , União Europeia , Temperatura Alta/efeitos adversos , Micro-Ondas/efeitos adversos , Modelos Químicos , Nylons/química , Nylons/efeitos da radiação , Plastificantes/efeitos adversos , Plastificantes/química , Plásticos/efeitos da radiação , Poliésteres/química , Poliésteres/efeitos da radiação , Polímeros/química , Polímeros/efeitos da radiação , Polipropilenos/química , Polipropilenos/efeitos da radiação , Silicones/química , Silicones/efeitos da radiação , Esterilização , Sulfonas/química , Sulfonas/efeitos da radiação
6.
Food Microbiol ; 57: 172-7, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27052716

RESUMO

In this study, the efficacy of using UV-C light to inactivate sliced cheese inoculated with Escherichia coli O157:H7, Salmonella Typhimurium, and Listeria monocytogenes and, packaged with 0.07 mm films of polyethylene terephthalate (PET), polyvinylchloride (PVC), polypropylene (PP), and polyethylene (PE) was investigated. The results show that compared with PET and PVC, PP and PE films showed significantly reduced levels of the three pathogens compared to inoculated but non-treated controls. Therefore, PP and PE films of different thicknesses (0.07 mm, 0.10 mm, and 0.13 mm) were then evaluated for pathogen reduction of inoculated sliced cheese samples. Compared with 0.10 and 0.13 mm, 0.07 mm thick PP and PE films did not show statistically significant reductions compared to non-packaged treated samples. Moreover, there were no statistically significant differences between the efficacy of PP and PE films. These results suggest that adjusted PP or PE film packaging in conjunction with UV-C radiation can be applied to control foodborne pathogens in the dairy industry.


Assuntos
Queijo/microbiologia , Queijo/efeitos da radiação , Escherichia coli O157/efeitos da radiação , Irradiação de Alimentos/métodos , Listeria monocytogenes/efeitos da radiação , Plásticos/química , Salmonella typhimurium/efeitos da radiação , Escherichia coli O157/crescimento & desenvolvimento , Contaminação de Alimentos/prevenção & controle , Embalagem de Alimentos/instrumentação , Listeria monocytogenes/crescimento & desenvolvimento , Plásticos/efeitos da radiação , Salmonella typhimurium/crescimento & desenvolvimento , Raios Ultravioleta
7.
Med Phys ; 42(11): 6211-20, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26520714

RESUMO

PURPOSE: The authors' objective was to systematically assess the performance of seven photodetectors used in plastic scintillation dosimetry. The authors also propose some guidelines for selecting an appropriate detector for a specific application. METHODS: The plastic scintillation detector (PSD) consisted of a 1-mm diameter, 10-mm long plastic scintillation fiber (BCF-60), which was optically coupled to a clear 10-m long optical fiber of the same diameter. A light-tight plastic sheath covered both fibers and the scintillator end was sealed. The clear fiber end was connected to one of the following photodetectors: two polychromatic cameras (one with an optical lens and one with a fiber optic taper replacing the lens), a monochromatic camera with an optical lens, a PIN photodiode, an avalanche photodiode (APD), or a photomultiplier tube (PMT). A commercially available W1 PSD was also included in the study, but it relied on its own fiber and scintillator. Each PSD was exposed to both low-energy beams (120, 180, and 220 kVp) from an orthovoltage unit and high-energy beams (6 and 23 MV) from a linear accelerator. Various dose rates were tested to identify the operating range and accuracy of each photodetector. RESULTS: For all photodetectors, the relative uncertainty was less than 5% for dose rates higher than 3 mGy/s. The cameras allowed multiple probes to be used simultaneously, but they are less sensitive to low-light signals. The PIN, APD, and PMT had higher sensitivity, making them more suitable for low dose rate and out-of-field dose monitoring. The relative uncertainty of the PMT was less than 1% at the lowest dose rate achieved (0.10 mGy/s), suggesting that it was optimal for use in live dosimetry. CONCLUSIONS: For dose rates higher than 3 mGy/s, the PIN diode is the most effective photodetector in terms of performance/cost ratio. For lower dose rates, such as those seen in interventional radiology or high-gradient radiotherapy, PMTs are the optimal choice.


Assuntos
Fotometria/instrumentação , Plásticos/efeitos da radiação , Contagem de Cintilação/instrumentação , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Contagem de Cintilação/métodos , Sensibilidade e Especificidade
8.
J Radiol Prot ; 35(2): 265-70, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25785500

RESUMO

Previous studies measured the effects of (222)Rn on various thermoluminescent dosemeters (TLDs). This study quantified the effects of (222)Rn on LiF : Ti,Mg chips encapsulated in plastic extremity rings. For 28 d, one batch of TLDs was left in a chamber with high radon levels, and another batch in a control chamber with normal background radon levels. A few TLDs in each batch were removed from the rings for direct exposure to the ambient air in each chamber. Passive continuous radon monitors (CRMs) recorded the (222)Rn levels. TLDs were processed using a third-party dosimetry company, CRM data were analysed, and the relationship between integrated (222)Rn concentration and TLD response was determined. The batch of TLDs in the experimental chamber showed a weak response to (222)Rn gas, which was in the order of 0.5 nSv Bq(-1) m(3) d(-1).


Assuntos
Artefatos , Fluoretos/efeitos da radiação , Compostos de Lítio/efeitos da radiação , Plásticos/efeitos da radiação , Radônio/análise , Dosimetria Termoluminescente/instrumentação , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Fluoretos/química , Gases/análise , Compostos de Lítio/química , Teste de Materiais , Plásticos/química , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente/métodos
9.
Environ Health ; 13(1): 41, 2014 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-24886603

RESUMO

BACKGROUND: Xenobiotic chemicals with estrogenic activity (EA), such as bisphenol A (BPA), have been reported to have potential adverse health effects in mammals, including humans, especially in fetal and infant stages. Concerns about safety have caused many manufacturers to use alternatives to polycarbonate (PC) resins to make hard and clear, reusable, plastic products that do not leach BPA. However, no study has focused on whether such BPA-free PC-replacement products, chosen for their perceived higher safety, especially for babies, also release other chemicals that have EA. METHODS: We used two, well-established, mammalian cell-based, assays (MCF-7 and BG1Luc) to assess the EA of chemicals that leached into over 1000 saline or ethanol extracts of 50 unstressed or stressed (autoclaving, microwaving, and UV radiation) BPA-free PC-replacement products. An EA antagonist, ICI 182,780, was used to confirm that agonist activity in leachates was due to chemicals that activated the mammalian estrogen receptor. RESULTS: Many unstressed and stressed, PC-replacement-products made from acrylic, polystyrene, polyethersulfone, and Tritan™ resins leached chemicals with EA, including products made for use by babies. Exposure to various forms of UV radiation often increased the leaching of chemicals with EA. In contrast, some BPA-free PC-replacement products made from glycol-modified polyethylene terephthalate or cyclic olefin polymer or co-polymer resins did not release chemicals with detectable EA under any conditions tested. CONCLUSIONS: This hazard assessment survey showed that many BPA-free PC- replacement products still leached chemicals having significant levels of EA, as did BPA-containing PC counterparts they were meant to replace. That is, BPA-free did not mean EA-free. However, this study also showed that some PC-replacement products did not leach chemicals having significant levels of EA. That is, EA-free PC-replacement products could be made in commercial quantities at prices that compete with PC-replacement products that were not BPA-free. Since plastic products often have advantages (price, weight, shatter-resistance, etc.) compared to other materials such as steel or glass, it is not necessary to forgo those advantages to avoid release into foodstuffs or the environment of chemicals having EA that may have potential adverse effects on our health or the health of future generations.


Assuntos
Estrogênios/análise , Plásticos/química , Compostos Benzidrílicos , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Estrogênios/química , Estrogênios/farmacologia , Etanol/química , Temperatura Alta , Humanos , Luciferases/metabolismo , Células MCF-7 , Micro-Ondas , Fenóis , Plásticos/efeitos da radiação , Receptores de Estrogênio/agonistas , Receptores de Estrogênio/metabolismo , Cloreto de Sódio/química , Raios Ultravioleta
10.
J Sci Food Agric ; 94(4): 713-20, 2014 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-23881467

RESUMO

BACKGROUND: Interest is increasing around both the use of plants as functional foods and the agronomic techniques which can increase nutrients and phytochemicals. Nevertheless, little research has focused on the effects of light on accumulation of active compounds in root storage organs. Red beet was treated with RED (red/far red ratio: 1.29; transmitted photosynthetically active radiation: 66.9%) and GREEN (red/far red ratio: 0.43; transmitted photosynthetically active radiation: 25.8%) photo-selective films and changes in nutrients and biomass accumulation were measured. RESULTS: Plants subjected to GREEN treatment had less dry weight accumulation both in storage roots (68%) and leaves (42%); moreover, soluble and structural carbohydrate concentration in roots was increased, as were the K, Mg and Zn concentrations (40.08, 2.95 and 0.023 mg g⁻¹ fresh weight, respectively). Conversely, GREEN lowered total phenolic concentration (0.33 vs. 0.47 mg g⁻¹ fresh weight) and antioxidant activity (0.65 vs. 0.94 µm Trolox equivalents g⁻¹ fresh weight) compared to CONTROL. Total pigment concentration was reduced by 20% and 48% with RED and GREEN treatments, respectively. CONCLUSION: Red beet showed a strong plasticity in its adaptation to light availability. Some macronutrients (fiber, sugars, minerals) can be concentrated in roots by modifying the amount and quality of the light, principally with GREEN photo-selective films.


Assuntos
Adaptação Fisiológica , Beta vulgaris/efeitos da radiação , Radiação Cósmica , Fotossíntese/efeitos da radiação , Folhas de Planta/efeitos da radiação , Raízes de Plantas/efeitos da radiação , Luz Solar , Antioxidantes/metabolismo , Beta vulgaris/crescimento & desenvolvimento , Beta vulgaris/metabolismo , Bebidas/análise , Carboidratos da Dieta/metabolismo , Fibras na Dieta/metabolismo , Qualidade dos Alimentos , Itália , Magnésio/metabolismo , Fenóis/metabolismo , Pigmentos Biológicos/análise , Pigmentos Biológicos/biossíntese , Folhas de Planta/crescimento & desenvolvimento , Folhas de Planta/metabolismo , Raízes de Plantas/crescimento & desenvolvimento , Raízes de Plantas/metabolismo , Plásticos/química , Plásticos/efeitos da radiação , Potássio na Dieta/metabolismo , Zinco/metabolismo
11.
Phys Med Biol ; 58(13): 4439-54, 2013 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-23756497

RESUMO

The purposes of this work are to assess the performance of a 2D plastic scintillation detectors array prototype for quality assurance in intensity-modulated radiation therapy (IMRT) and to determine its sensitivity and specificity to positioning errors of one multileaf collimator (MLC) leaf and one MLC leaf bank by applying the principles of signal detection theory. Ten treatment plans (step-and-shoot delivery) and one volumetric modulated arc therapy plan were measured and compared to calculations from two treatment-planning systems (TPSs) and to radiochromic films. The averages gamma passing rates per beam found for the step-and-shoot plans were 95.8% for the criteria (3%, 2 mm), 97.8% for the criteria (4%, 2 mm), and 98.1% for the criteria (3%, 3 mm) when measurements were compared to TPS calculations. The receiver operating characteristic curves for the one leaf errors and one leaf bank errors were determined from simulations (theoretical upper limits) and measurements. This work concludes that arrays of plastic scintillation detectors could be used for IMRT quality assurance in clinics. The use of signal detection theory could improve the quality of dosimetric verifications in radiation therapy by providing optimal discrimination criteria for the detection of different classes of errors.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde/métodos , Garantia da Qualidade dos Cuidados de Saúde/normas , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/normas , Contagem de Cintilação/instrumentação , Contagem de Cintilação/normas , Desenho de Equipamento , Análise de Falha de Equipamento , Plásticos/efeitos da radiação , Quebeque , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Med Phys ; 40(6): 062101, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23718599

RESUMO

PURPOSE: The goal of this study was to prove the feasibility of using a single-fiber multipoint plastic scintillation detector (mPSD) as an in vivo verification tool during (192)Ir high-dose-rate brachytherapy treatments. METHODS: A three-point detector was built and inserted inside a catheter-positioning template placed in a water phantom. A hyperspectral approach was implemented to discriminate the different optical signals composing the light output at the exit of the single collection optical fiber. The mPSD was tested with different source-to-detector positions, ranging from 1 to 5 cm radially and over 10.5 cm along the longitudinal axis of the detector, and with various integration times. Several strategies for improving the accuracy of the detector were investigated. The device's accuracy in detecting source position was also tested. RESULTS: Good agreement with the expected doses was obtained for all of the scintillating elements, with average relative differences from the expected values of 3.4 ± 2.1%, 3.0 ± 0.7%, and 4.5 ± 1.0% for scintillating elements from the distal to the proximal. A dose threshold of 3 cGy improved the general accuracy of the detector. An integration time of 3 s offered a good trade-off between precision and temporal resolution. Finally, the mPSD measured the radioactive source positioning uncertainty to be no more than 0.32 ± 0.06 mm. The accuracy and precision of the detector were improved by a dose-weighted function combining the three measurement points and known details about the geometry of the detector construction. CONCLUSIONS: The use of a mPSD for high-dose-rate brachytherapy dosimetry is feasible. This detector shows great promise for development of in vivo applications for real-time verification of treatment delivery.


Assuntos
Braquiterapia/instrumentação , Tecnologia de Fibra Óptica/instrumentação , Radioisótopos de Irídio/análise , Radioisótopos de Irídio/uso terapêutico , Plásticos/efeitos da radiação , Contagem de Cintilação/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Med Phys ; 40(4): 041724, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23556894

RESUMO

PURPOSE: Beam range control is the essence of radiotherapy with heavy charged particles. In conventional broad-beam delivery, fine range adjustment is achieved by insertion of range shifting and compensating materials. In dosimetry, solid phantoms are often used for convenience. These materials should ideally be equivalent to water. In this study, the authors evaluated dosimetric water equivalence of four common plastics, high-density polyethylene (HDPE), polymethyl methacrylate (PMMA), polyethylene terephthalate (PET), and polyoxymethylene (POM). METHODS: Using the Bethe formula for energy loss, the Gottschalk formula for multiple scattering, and the Sihver formula for nuclear interactions, the authors calculated the effective densities of the plastics for these interactions. The authors experimentally measured variation of the Bragg peak of carbon-ion beams by insertion of HDPE, PMMA, and POM, which were compared with analytical model calculations. RESULTS: The theoretical calculation resulted in slightly reduced multiple scattering and severely increased nuclear interactions for HDPE, compared to water and the other plastics. The increase in attenuation of carbon ions for 20-cm range shift was experimentally measured to be 8.9% for HDPE, 2.5% for PMMA, and 0.0% for POM while PET was theoretically estimated to be in between PMMA and POM. The agreement between the measurements and the calculations was about 1% or better. CONCLUSIONS: For carbon-ion beams, POM was dosimetrically indistinguishable from water and the best of the plastics examined in this study. The poorest was HDPE, which would reduce the Bragg peak by 0.45% per cm range shift, although with marginal superiority for reduced multiple scattering. Between the two clear plastics, PET would be superior to PMMA in dosimetric water equivalence.


Assuntos
Radioterapia com Íons Pesados/métodos , Plásticos/química , Plásticos/efeitos da radiação , Radiometria/instrumentação , Radiometria/métodos , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Photochem Photobiol ; 88(5): 1211-6, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22540924

RESUMO

The results of many investigations on low-level laser therapy are contradictory and this is due to the large number of illumination parameters as well as the inability to measure the possible effects after irradiation with the necessary objectivity and the fact that the light needs to pass thorough barriers (usually the plastic of the culture dish/plate and culture medium) to reach the cells. In this manner, the objective of this study was to determine the absorption coefficient, penetration depth and effective transmission in materials commonly used in cell cultures. Among the most commonly used wavelengths in low-level laser therapy, the lowest absorption coefficients were reached by DMEM and RPMI (α = 0.03 cm(-1)), from 633 to 690 nm, which reach an effective transmission of 93% of incident radiation and penetration depth of 33 cm. Among the solid materials in the same range of the electromagnetic spectrum, the lowest absorption coefficient was obtained for the polystyrene (Petri dish and well plate), with α = 1.31 cm(-1), 78% of effective transmission and 0.76 cm of penetration depth. This article also presents a simple equation for estimating the amount of energy that will actually reach the sample.


Assuntos
Meios de Cultura/efeitos da radiação , Plásticos/efeitos da radiação , Radiometria/normas , Luz , Doses de Radiação , Análise Espectral
15.
Med Phys ; 39(1): 429-36, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22225313

RESUMO

PURPOSE: To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. METHODS: The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S(c,p)) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured. The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. RESULTS: Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 × 10 cm(2) field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S(c,p) within 1.4% and 0.7% for 5 and 35 mm diameter cone, respectively. Furthermore, volume averaging of the IC can be observed for the 5 mm aperture where it differs by as much as 9.1% compared to the PSD measurement. The angular dependency of the UD is also observed, unveiled by an under-response around 2.5% of both 5 and 35 mm apertures. CONCLUSIONS: Output Factors and dose profiles measurements performed, respectively, with the PSD and the PSDCA were in agreement with those obtained with the UD and EBT2 films. For stereotactic radiosurgery treatment verification, the PSD gives accurate results compared to the planning system and the IC once the latter is corrected to compensate for the averaging effect of the IC. The PSD provides precise results when used as a single detector or in a dense array, resulting in a great potential for stereotactic radiosurgery QA measurements.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde/métodos , Garantia da Qualidade dos Cuidados de Saúde/normas , Radiocirurgia/instrumentação , Radiocirurgia/normas , Contagem de Cintilação/instrumentação , Contagem de Cintilação/normas , Canadá , Desenho de Equipamento , Análise de Falha de Equipamento , Plásticos/efeitos da radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Med Phys ; 37(8): 4331-42, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20879593

RESUMO

PURPOSE: This work presents the experimental extraction of the overall perturbation factor PQ in megavoltage electron beams for NACP-02 and Roos parallel-plate ionization chambers using a plastic scintillation detector (PSD). METHODS: The authors used a single scanning PSD mounted on a high-precision scanning tank to measure depth-dose curves in 6, 12, and 18 MeV clinical electron beams. The authors also measured depth-dose curves using the NACP-02 and PTW Roos chambers. RESULTS: The authors found that the perturbation factors for the NACP-02 and Roos chambers increased substantially with depth, especially for low-energy electron beams. The experimental results were in good agreement with the results of Monte Carlo simulations reported by other investigators. The authors also found that using an effective point of measurement (EPOM) placed inside the air cavity reduced the variation of perturbation factors with depth and that the optimal EPOM appears to be energy dependent. CONCLUSIONS: A PSD can be used to experimentally extract perturbation factors for ionization chambers. The dosimetry protocol recommendations indicating that the point of measurement be placed on the inside face of the front window appear to be incorrect for parallel-plate chambers and result in errors in the R50 of approximately 0.4 mm at 6 MeV, 1.0 mm at 12 MeV, and 1.2 mm at 18 MeV.


Assuntos
Plásticos/efeitos da radiação , Radiometria/instrumentação , Radioterapia Conformacional/instrumentação , Contagem de Cintilação/instrumentação , Análise de Falha de Equipamento/instrumentação , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Artigo em Inglês | MEDLINE | ID: mdl-20931418

RESUMO

A variety of melaware articles were tested for the migration of melamine into the food simulant 3% w/v acetic acid as a benchmark, and into other food simulants, beverages and foods for comparison. The results indicate that the acidity of the food simulant plays a role in promoting migration, but not by as much as might have been anticipated, since 3% acetic acid gave migration values about double those obtained using water under the same time and temperature test conditions. In contrast, migration into the fatty food simulant olive oil was not detectable and at least 20-fold lower than with the aqueous food simulants. This was expected given the solubility properties of melamine and the characteristics of the melaware plastic. Migration levels into hot acidic beverages (apple juice, tomato juice, red-fruit tea and black coffee) were rather similar to the acetic acid simulant when the same time and temperature test conditions are used, e.g. 2 h at 70°C. However, migration levels into foods that were placed hot into melaware articles and then allowed to cool on standing were much lower (6-14 times lower) than if pre-heated food was placed into the articles and then maintained (artificially) at that high temperature in the same way that a controlled time-temperature test using simulants would be conducted. This very strong influence of time and especially temperature was manifest in the effects seen of microwave heating of food or beverage in the melaware articles. Here, despite the short duration of hot contact, migration levels were similar to simulants used for longer periods, e.g. 70°C for 2 h. This is rationalized in terms of the peak temperature achieved on microwave heating, which may exceed 70°C, counterbalancing the shorter time period held hot. There was also evidence that when using melaware utensils in boiling liquids, as for stovetop use of spatulas, the boiling action of circulating food/simulant can have an additional effect in promoting surface erosion, increasing the plastic decomposition and so elevating the melamine release.


Assuntos
Análise de Alimentos , Contaminação de Alimentos , Plásticos/química , Triazinas/análise , Bebidas/análise , Bebidas/efeitos da radiação , Qualidade de Produtos para o Consumidor , Culinária , Utensílios de Alimentação e Culinária , Alimentos/efeitos da radiação , Manipulação de Alimentos/métodos , Embalagem de Alimentos , Formaldeído/química , Concentração de Íons de Hidrogênio , Micro-Ondas/efeitos adversos , Modelos Químicos , Plásticos/efeitos adversos , Plásticos/efeitos da radiação , Temperatura , Fatores de Tempo , Triazinas/química
18.
Environ Sci Pollut Res Int ; 17(7): 1323-30, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20309737

RESUMO

BACKGROUND, AIMS, AND SCOPE: Heavy metal contaminants in environment, especially in drinking water, are always of great concern due to their health impact. Due to the use of heavy metals as catalysts during plastic syntheses, particularly antimony, human exposure to metal release from plastic bottles has been a serious concern in recent years. The aim and scope of this study were to assess metal contaminations leaching out from a series of recycling plastic bottles upon treatments. METHODOLOGY: In this study, leaching concentrations of 16 metal elements were determined in 21 different types of plastic bottles from five commercial brands, which were made of recycling materials ranging from no. 1 to no. 7. Several sets of experiments were conducted to study the factors that could potentially affect the metal elements leaching from plastic bottles, which include cooling with frozen water, heating with boiling water, microwave, incubating with low-pH water, outdoor sunlight irradiation, and in-car storage. RESULTS: Heating and microwave can lead to a noticeable increase of antimony leaching relative to the controls in bottle samples A to G, and some even reached to a higher level than the maximum contamination level (MCL) of the US Environmental Protection Agency (USEPA) regulations. Incubation with low-pH water, outdoor sunlight irradiation, and in-car storage had no significant effect on antimony leaching relative to controls in bottle samples A to G, and the levels of antimony leaching detected were below 6 ppb which is the MCL of USEPA regulations. Cooling had almost no effect on antimony leaching based on our results. For the other interested 15 metal elements (Al, V, Cr, Mn, Co, Ni, Cu, As, Se, Mo, Ag, Cd, Ba, Tl, Pb), no significant leaching was detected or the level was far below the MCL of USEPA regulations in all bottle samples in this study. In addition, washing procedure did contribute to the antimony leaching concentration for polyethylene terephthalate (PET) bottles. The difference of antimony leaching concentration between washing procedure involved and no washing procedure involved (AC) was larger than zero for samples A to G. This interesting result showed that higher antimony concentration was detected in experiments with no washing procedures compared with those experiments with washing procedures. Our study results indicate that partial antimony leaching from PET bottles comes from contaminations on the surface of plastic during manufacturing process, while major antimony leaching comes from conditional changes. CONCLUSION: The results revealed that heating and microwaving enhance antimony leaching significantly in PET plastic bottles. Plastic bottle manufacturers should consider the contaminations during manufacturing process and washing bottles before first use was strongly recommended to remove those contaminants.


Assuntos
Conservação dos Recursos Naturais/métodos , Embalagem de Alimentos , Metais/análise , Plásticos/química , Eliminação de Resíduos/métodos , Água/química , Antimônio/análise , Arsênio/análise , Temperatura Baixa/efeitos adversos , Contaminação de Alimentos/prevenção & controle , Temperatura Alta/efeitos adversos , Concentração de Íons de Hidrogênio , Micro-Ondas/efeitos adversos , Plásticos/efeitos da radiação , Polietilenotereftalatos/química , Polietilenotereftalatos/efeitos da radiação , Polímeros/química , Polímeros/efeitos da radiação , Selênio/análise , Luz Solar/efeitos adversos
19.
Health Phys ; 98(2): 388-94, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20065710

RESUMO

In case of acute exposure to ionizing radiation, the dose absorbed by the victims has to be rapidly and accurately assessed in order to choose an appropriate medical treatment. Tooth enamel and bone biopsies measured by EPR spectrometry are often used as dose indicators, due to the good radiation sensitivity and the stability of EPR radiation-sensitive signals. Nevertheless, the invasive sampling of teeth and bones limits the application of this technique to retrospective dosimetry. Therefore, we have investigated an alternative non-invasive methodology. We have surveyed with EPR spectrometry the dosimetric properties of the plastics that can be found in personal effects such as glasses (CR-39, polycarbonate), mobile phones (PMMA, polycarbonate), watches and buttons. Dose response, signal stability and effects of storage conditions were investigated. Significant signal fading limits the use for radiation accident dosimetry. Few plastics present the required characteristics to be used in case of a radiation accident.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/instrumentação , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Plásticos/química , Plásticos/efeitos da radiação , Liberação Nociva de Radioativos , Radiometria/instrumentação , Radiometria/métodos , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Teste de Materiais , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Radiat Prot Dosimetry ; 126(1-4): 623-5, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17502310

RESUMO

At the Northern Illinois University Institute for Neutron Therapy at Fermilab, the clinical tissue-equivalent ionisation chamber response is measured every treatment day using a cesium source that was configured to match readings obtained at the National Bureau of Standards. Daily measurements are performed in air using the air-to-tissue dose conversion factors given in AAPM Report #7. The measured exposure calibration factors have been tabulated and graphed as a function of time from 1978 to present. For A-150 plastic ionisation chambers, these factors exhibit a sinusoidal variation with a period of approximately 1 y and amplitude of +/- 1%. This variation, attributable to the hygroscopic nature of A-150 plastic, is correlated with the relative humidity of the facility, and is greater than the humidity corrections for gas described in the literature. The data suggest that chamber calibration should be performed at least weekly to accommodate these variations.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Nêutrons , Plásticos/efeitos da radiação , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Illinois , Íons , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade