Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.101
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Methods Mol Biol ; 2758: 179-195, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38549014

RESUMO

Peptide therapeutics is gaining momentum. Advances in the field of peptidomics have enabled researchers to harvest vital information from various organisms and tissue types concerning peptide existence, expression and function. The development of mass spectrometry techniques for high-throughput peptide quantitation has paved the way for the identification and discovery of numerous known and novel peptides. Though much has been achieved, scientists are still facing difficulties when it comes to reducing the search space of the large mass spectrometry-generated peptidomics datasets and focusing on the subset of functionally relevant peptides. Moreover, there is currently no straightforward way to analytically compare the distributions of bioactive peptides in distinct biological samples, which may reveal much useful information when seeking to characterize tissue- or fluid-specific peptidomes. In this chapter, we demonstrate how to identify, rank, and compare predicted bioactive peptides and bioactivity distributions from extensive peptidomics datasets. To aid this task, we utilize MultiPep, a multi-label deep learning approach designed for classifying peptide bioactivities, to identify bioactive peptides. The predicted bioactivities are synergistically combined with protein information from the UniProt database, which assist in navigating through the jungle of putative therapeutic peptides and relevant peptide leads.


Assuntos
Aprendizado Profundo , Peptídeos/química , Espectrometria de Massas , Encéfalo , Plasma/química
2.
Artigo em Inglês | MEDLINE | ID: mdl-38330770

RESUMO

Cisplatin is a potent cytotoxic agent used in the treatment of various malignancies and exerts its antitumor effect through malignant cell DNA damage and apoptosis induction. Evaluation of systemic delivery of cisplatin is important in optimization of cisplatin treatment. However, accurate quantification of systemic cisplatin is challenging due to its various forms in circulation. This study aimed to develop a sensitive (LOQ < 0.1 µg/mL) and precise Ultra Performance Liquid Chromatography (UPLC) - Tandem Mass Spectrometry (MS/MS) method for quantifying free cisplatin in microdialysates and plasma. Furthermore the aim was to compare free cisplatin concentrations measured in standard plasma samples with those obtained from intravenous microdialysis catheters in a porcine model. The method developed utilizes dichloro(ethylenediamine)platinum(II) as an internal standard that co-elutes with cisplatin, ensuring precise correction for ion suppression/enhancement effects. The method was validated, demonstrating linearity up to 100 µg/mL and good intermediate precision (CV% < 6 %) in the range of 1.0-100 µg/mL, with an LOQ of 0.03 µg/mL. The pharmacokinetic parameters (AUC0-last, Cmax, T1/2, and Tmax) showed no significant differences between the two sampling methods. This validated LC-MS/MS method provides a reliable tool for quantifying systemic free cisplatin concentrations, facilitating future systemic and local pharmacokinetic evaluations for optimization of cisplatin-based cancer treatments.


Assuntos
Cisplatino , Espectrometria de Massas em Tandem , Animais , Suínos , Cromatografia Líquida/métodos , Cisplatino/análise , Cisplatino/química , Espectrometria de Massas em Tandem/métodos , Plasma/química , Espectrometria de Massa com Cromatografia Líquida , Reprodutibilidade dos Testes , Cromatografia Líquida de Alta Pressão/métodos
3.
Anal Chim Acta ; 1288: 342144, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38220279

RESUMO

A new hydrophilic interaction liquid chromatography - mass spectrometry method is developed for low-abundant phospholipids and sphingolipids in human plasma and serum. The optimized method involves the Cogent Silica type C hydride column, the simple sample preparation by protein precipitation, and the removal of highly abundant lipid classes using the postcolumn valve directed to waste during two elution windows. The method allows a highly confident and sensitive identification of low-abundant lipid classes in human plasma (246 lipid species from 24 lipid subclasses) based on mass accuracy and retention dependencies in both polarity modes. The method is validated for quantitation using two internal standards (if available) for each lipid class and applied to human plasma and serum samples obtained from patients with pancreatic ductal adenocarcinoma (PDAC), healthy controls, and NIST SRM 1950. Multivariate data analysis followed by various statistical projection methods is used to determine the most dysregulated lipids. Significant downregulation is observed for lysophospholipids with fatty acyl composition 16:0, 18:0, 18:1, and 18:2. Distinct trends are observed for phosphatidylethanolamines (PE) in relation to the bonding type of fatty acyls, where most PE with acyl bonds are upregulated, while ether/plasmenyl PE are downregulated. For the sphingolipid category, sphingolipids with very long N-acyl chains are downregulated, while sphingolipids with shorter N-acyl chains were upregulated in PDAC. These changes are consistently observed for various classes of sphingolipids, ranging from ceramides to glycosphingolipids, indicating a possible metabolic disorder in ceramide biosynthesis caused by PDAC.


Assuntos
Neoplasias Pancreáticas , Esfingolipídeos , Humanos , Esfingolipídeos/análise , Plasma/química , Soro , Ceramidas
4.
Photodiagnosis Photodyn Ther ; 45: 103900, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38081568

RESUMO

BACKGROUND: The incidence of common urinary system tumors has been rising rapidly in recent years, and most urinary system-derived tumors lack specific biomarkers. OBJECTIVES: To explore the efficacy of surface-enhanced Raman spectroscopy (SERS) of blood plasma in screening three common urinary system tumors, including bladder cancer (BC), prostate cancer (PCa), and renal cell carcinoma (RCC). METHODS: SERS plasma spectra from 125 plasma samples, including 25 PCa, 38 RCC, 24 BC patients, and 38 normal volunteers, were collected. All candidates had no other comorbidities. The Diagnosis was based on the combination of Principal Component Analysis (PCA) and Linear Discriminant Analysis (LDA), and the effectiveness of the diagnostic algorithms was verified using the Receiver Operating Characteristic Curve (ROC). RESULTS: There are significant differences in SERS signals between PCa, BC, RCC, and normal plasma, especially at 639, 889, 1010, 1136, and 1205 cm-1. The PCA-LDA results show that high sensitivity (100 %), specificity (100 %), and accuracy (100 %) could be achieved for screening the PCa, RCC, BC group vs. the normal group, the PCa group vs. the BC and RCC group, respectively. The diagnostic sensitivity, specificity, and accuracy for the BC group vs. the RCC group are 79.2 %, 71.1 %, and 75.15 %, respectively. The integrated area under the ROC curve (AUC) is 1.0, 1.0, and 1.0 for the PCa, RCC, and BC group vs. the normal group, respectively. The AUC of the PCa group vs. the BC group and RCC group and the BC group vs. the RCC group are 1.0, 1.0, and 0.842, respectively. CONCLUSIONS: Label-free plasma-SERS technology with PCA-LDA analysis could be a useful screening method for detecting urinary system tumors (PCa, RCC, and BC) in this exploratory study.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Fotoquimioterapia , Neoplasias da Bexiga Urinária , Masculino , Humanos , Análise Espectral Raman/métodos , Carcinoma de Células Renais/diagnóstico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Plasma/química , Neoplasias da Bexiga Urinária/diagnóstico , Neoplasias Renais/diagnóstico
5.
Anal Chim Acta ; 1279: 341791, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37827685

RESUMO

Metabolomics is the study of small molecules, primarily metabolites, that are produced during metabolic processes. Analysis of the composition of an organism's metabolome can yield useful information about an individual's health status at any given time. In recent years, the development of large-scale, targeted metabolomic methods has allowed for the analysis of biological samples using analytical techniques such as LC-MS/MS. This paper presents a large-scale metabolomics method for analysis of biological samples, with a focus on quantification of metabolites found in blood plasma. The method comprises a 10-min chromatographic separation using HILIC and RP stationary phases combined with positive and negative electrospray ionization in order to maximize metabolome coverage. Complete analysis of a single sample can be achieved in as little as 40 min using the two columns and dual modes of ionization. With 540 metabolites and the inclusion of over 200 analytical standards, this method is comprehensive and quantitatively robust when compared to current targeted metabolomics methods. This study uses a large-scale evaluation of metabolite recovery from plasma that enables absolute quantification of metabolites by correcting for analyte loss throughout processes such as extraction, handling, or storage. In addition, the method was applied to plasma collected from adjuvant breast cancer patients to confirm the suitability of the method to clinical samples.


Assuntos
Metabolômica , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Metabolômica/métodos , Metaboloma , Plasma/química
6.
Anal Chem ; 95(24): 9263-9270, 2023 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-37279458

RESUMO

Cell-free DNA in human blood plasma (cfDNA) is now widely used and studied as a biomarker for several physiological and pathological situations. In addition to genetic and epigenetic alterations that provide information about the presence and the nature of non-constitutive DNA in the body, cfDNA concentration and size distribution may potentially be independent biomarkers suitable for monitoring at-risk patients and therapy efficacy. Here, we describe a simple, in-line, method, which measures cfDNA concentration and size distribution from only a few microliters of plasma without the need to extract and/or concentrate the DNA prior to the analysis. This method is based on a dual hydrodynamic and electrokinetic actuation, adapted for samples containing salts and proteins such as biological fluids. The method provides analytical performances equivalent to those obtained after purification and concentration of cfDNA, with a precision of ∼1% for size features and of 10-20% for the concentrations of the different size fractions. We show that concentration and size distribution of cfDNA analyzed from plasma can differentiate advanced lung cancer patients from healthy controls. This simple and cost-effective method should facilitate further investigations into the potential clinical usefulness of cfDNA size profiling.


Assuntos
Ácidos Nucleicos Livres , Neoplasias Pulmonares , Humanos , DNA , Biomarcadores Tumorais , Plasma/química
7.
Paediatr Anaesth ; 33(9): 720-727, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37368461

RESUMO

BACKGROUND: Neonates undergoing surgery are at greater risk of requiring packed red blood cell transfusion. Pediatric transfusion practices vary widely between countries and institutions, especially in the management of neonates. AIMS: The aim of this study was to describe the use of intraoperative blood product transfusion during neonatal surgery in current clinical practice at our institution. METHODS: A retrospective contextual, descriptive, and comparative study was conducted at Chris Hani Baragwanath Academic Hospital. A total of 1078 anesthetic records of neonates who underwent surgery from January 1, 2015 to December 31, 2019 were reviewed. Descriptive and inferential statistics were used to analyze the data. RESULTS: Blood products were transfused during 374 (34.7%) neonatal surgeries. Packed red blood cells, platelet concentrate, and fresh frozen plasma were administered during 327 (30.3%), 133 (12.3%), and 85 (7.9%) of the total 1078 surgeries, respectively. The median (interquartile range) volume of packed red blood cells, fresh frozen plasma, platelets, and clear fluid administered was 15 (10-21.8) mL/kg, 12.3 (10-23.5) mL/kg, 13.6 (10-20.5) mL/kg, and 19 (9.1-28.8) mL/kg, respectively. Very low weight, low preoperative hemoglobin, long total anesthetic time, emergency surgery, and major surgery were independently associated with blood product transfusion. Gestational age at birth, blood product transfusion, emergency surgery, and major surgery were independently associated with the composite adverse outcomes. The median preoperative hemoglobin was 11.8 g/dL. CONCLUSIONS: Intraoperative blood product transfusion occurred at a much higher rate with a high median pre-transfusion hemoglobin compared to other studies.


Assuntos
Transfusão de Sangue , Transfusão de Eritrócitos , Recém-Nascido , Humanos , Criança , Estudos Retrospectivos , Hemoglobinas/análise , Plasma/química
8.
Methods Mol Biol ; 2620: 273-286, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37010770

RESUMO

Arginase, an enzyme involved in the urea cycle, is gaining attention as a critical player in numerous chronic pathologies. Additionally, increased activity of this enzyme has been shown to correlate with poor prognosis in a range of cancers. Colorimetric assays that measure the conversion of arginine to ornithine have long been used to determine the activity of arginase. However, this analysis is hindered by a lack of standardization across protocols. Here, we describe in detail a novel revision of the Chinard's colorimetric assay used to determine arginase activity. Dilution series of patient plasma are plotted to form a logistic function, from which activity can be interpolated by comparison to an ornithine standard curve. Inclusion of patient dilution series rather than a single point increases the robustness of the assay. This high-throughput microplate assay analyzes 10 samples per plate to produce highly reproducible results.


Assuntos
Arginase , Colorimetria , Humanos , Colorimetria/métodos , Arginina , Ornitina , Plasma/química
9.
Artigo em Inglês | MEDLINE | ID: mdl-37028170

RESUMO

A selective and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for accurate determination of CHF6550 and its main metabolite in rat plasma and lung homogenate samples. All biological samples were prepared by simple protein precipitation method using deuterated internal standards. The analytes were separated on a HSS T3 analytical column with 3.2 min run time at flow rate of 0.5 mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer equipped with positive-ion electrospray ionization by selected-reaction monitoring of the transitions at m/z 735.3 â†’ 98.0 for CHF6550 and m/z 638.3 â†’ 319.2 and 638.3 â†’ 376.2 for CHF6671. The calibration curves for plasma samples were linear between 50 and 50000 pg/mL for both analytes. The calibration curves for lung homogenate samples were linear within 0.1-100 ng/mL for CHF6550 and 0.3-300 ng/mL for CHF6671. The method was successfully applied to a 4-week toxicity study.


Assuntos
Plasma , Espectrometria de Massas em Tandem , Ratos , Animais , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Padrões de Referência , Plasma/química , Calibragem , Reprodutibilidade dos Testes
10.
Biomed Chromatogr ; 37(8): e5653, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37052131

RESUMO

Gansuibanxia decoction (GSBXD), a traditional Chinese medicine (TCM) formula with 2000 years of history, has good efficacies on treating cancerous ascites, pleural effusion, etc. However, little is known about its metabolite profiles owing to the lack of in vivo studies. In this study, we explored the prototypes and metabolites of GSBXD in rat plasma and urine using UHPLC-Q-TOF/MS technology. A total of 82 GSBXD-related xenobiotic bioactive components (38 prototypes and 44 metabolites) were confirmed or tentatively characterized, including 32 prototypes and 29 metabolites in plasma, and 25 prototypes and 29 metabolites in urine. The results showed that the bioactive components absorbed in vivo mainly contained diterpenoids, triterpenoids, flavonoids and monoterpene glycosides. Both phase I reactions (methylation, reduction, demethylation, hydrolysis, hydroxylation and oxidation) and phase II reactions (glucuronidation and sulfation) were involved in the metabolism of GSBXD in vivo. This study will provide a foundation for the quality control, pharmacological study and clinical application of GSBXD.


Assuntos
Medicamentos de Ervas Chinesas , Ratos , Animais , Cromatografia Líquida de Alta Pressão/métodos , Medicina Tradicional Chinesa , Plasma/química , Flavonoides/análise
11.
J Am Soc Mass Spectrom ; 34(4): 754-762, 2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-36975161

RESUMO

Mass spectrometry-based clinical proteomics requires high throughput, reproducibility, robustness, and comprehensive coverage to serve the needs of clinical diagnosis, prognosis, and personalized medicine. Oftentimes these requirements are contradictory to each other. We report the development of a streamlined High-Throughput Plasma Proteomics (sHTPP) platform for untargeted profiling of the blood plasma proteome, which includes 96-well plates and simplified procedures for sample preparation, disposable trap column for peptide loading, robust liquid chromatographic system for separation, data-independent acquisition in tandem mass spectrometry, and DIA-NN, FragPipe, and in-house peptide spectral library-based data analysis. Using the optimized platform at a throughput of 60 samples per day, over 600 protein groups including 57 FDA-approved biomarkers can be consistently identified from whole human plasma, and more than 85% of the detected proteins have 100% completeness in quantitative values across 300 samples. The balance achieved between proteome coverage, throughput, and reproducibility of this sHTPP platform makes it promising in clinical settings, where a large number of samples are to be measured quickly and reliably to support various needs of clinical medicine.


Assuntos
Proteoma , Proteômica , Humanos , Proteômica/métodos , Proteoma/análise , Reprodutibilidade dos Testes , Biblioteca de Peptídeos , Peptídeos , Espectrometria de Massas em Tandem/métodos , Plasma/química
12.
Artigo em Inglês | MEDLINE | ID: mdl-36906955

RESUMO

The measurement of dehydroepiandrosterone-sulphate (DHEAs) is an important second-line test to aid in the diagnosis of premature adrenarche, peripubertal gynaecomastia in males and in identifying the source of elevated androgens in females. Historically, DHEAs has been measured by immunoassay platforms which are prone to poor sensitivity and more importantly poor specificity. The aim was to develop an LC-MSMS method for the measurement of DHEAs in human plasma and serum, develop an in-house paediatric (<6 year old) reference limit and compare the performance against the Abbott Alinity DHEAs immunoassay method. Following pre-treatment with an internal standard, samples were loaded onto EVOLUTE® EXPRESS ABN plate. Analytes were separated with reverse-phase chromatography using ACQUITY® UPLC® HSS T3 2.1 mm × 50 mm, 1.8 µm column. Mass spectrometry detection was performed using a Waters® Xevo TQ-XS in electrospray negative mode. For the paediatric reference range, samples were collected from an inpatient setting (age ≤ 6 years old) with no evidence of adrenal dysfunction or history of/current steroid use. The method comparison was performed using samples from this cohort aged between 0 and 52 weeks. The assay demonstrated linearity up to 15 µmol/L (r2 > 0.99) with a functional sensitivity of 0.1 µmol/L. Accuracy results revealed a mean bias of 0.7% (-14% to 15%) when compared against the NEQAS EQA LC-MSMS consensus mean (n = 48). The paediatric reference limit was calculated as ≤ 2.3 µmol/L (95% C.I. 1.4 to 3.8 µmol/L) for ≤ 6 year olds (n = 38). Comparison of neonatal (<52 weeks) DHEAs with the Abbott Alinity revealed that the immunoassay ran at a 166% positive bias (n = 24) which appeared to lessen with increasing age. Described is a robust LC-MSMS method for the measurement of plasma or serum DHEAs validated against internationally recognised protocols. Comparison of paediatric samples of <52 weeks against an immunoassay platform demonstrated that in the immediate new-born period results generated from the LC-MSMS method offer superior specificity than an immunoassay platform.


Assuntos
Plasma , Espectrometria de Massas em Tandem , Masculino , Recém-Nascido , Feminino , Humanos , Criança , Lactente , Sulfato de Desidroepiandrosterona/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Plasma/química , Imunoensaio/métodos
13.
Molecules ; 28(3)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36771043

RESUMO

The aim of the current research was to develop a simple and rapid mass spectrometry-based assay for the determination of 15 steroid hormones in human plasma in a single run, which would be suitable for a routine practice setting. For this purpose, we designed a procedure based on the 2D-liquid chromatography-tandem mass spectrometry with a minimalistic sample pre-treatment. In our arrangement, the preparation of one sample takes only 10 min and can accommodate 40 samples per hour when tested in series. The following analytical run is 18 min long for all steroid hormones. In addition, we developed an independent analytical run for estradiol, significantly increasing the assay accuracy while taking an additional 10 min to perform an analytical run of a sample. The optimized method was applied to a set of human plasma samples, including chylous. Our results indicate the linearity of the method for all steroid hormones with squared regression coefficients R2 ≥ 0.995, within-run and between-run precision (RSD < 6.4%), and an accuracy of 92.9% to 106.2%. The absolute recovery for each analyzed steroid hormone ranged between 101.6% and 116.5%. The method detection limit for 15 steroid hormones ranged between 0.008 nmol/L (2.88 pg/mL) for aldosterone and 0.873 nmol/L (0.252 ng/mL) for DHEA. For all the analytes, the lowest calibration point relative standard deviation was less than 10.8%, indicating a good precision of the assay within the lowest concentration of interest. In conclusion, in this method article, we describe a simple, sensitive, and cost-effective 2D-LC/MS/MS method suitable for the routine analysis of a complex of steroid hormones allowing high analytical specificity and sensitivity despite minimal sample processing and short throughput times.


Assuntos
Esteroides , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Esteroides/análise , Plasma/química , Estradiol , Reprodutibilidade dos Testes
14.
Methods Mol Biol ; 2630: 135-143, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36689181

RESUMO

MicroRNAs (miRNAs) comprise a large group of small noncoding RNAs within a heterogeneous entity of noncoding RNAs, forming potent functional tools regulating the crucial biological processes within cells and the body. Cell-free miRNAs have become one of the novel promising diagnostic, predictive, and prognostic biomarkers for various diseases extensively investigated in recent years. This is due to their presence within extracellular fractions of various body fluids suggesting their potential as noninvasive "liquid biopsy" in case of their dysregulated expression.Among the body fluids, blood plasma and serum along with urine are the most commonly investigated sources of various types of cell-free miRNAs. Another body fluid, i.e., ascites (effusion, peritoneal/pleural fluid) may be the clinically important fluid particularly associated with carcinogenesis in ovarian carcinomas and hepatocellular carcinomas or in case of liver cirrhosis.Here, we provide a protocol for an expression profiling study based on qPCR analyses aimed at finding novel candidate miRNAs via small-scale or large-scale screening and evaluation experiments using liquid biopsies of blood plasma, ascites, and urine. Using this approach may be worth in cases where no (or limited) information is available on miRNA expression in particular diseases and geographic regions, for validation of previously published miRNAs with promising diagnostic potential, particularly in situations where follow-up study is aimed at validating miRNAs coming from (micro) array or NGS experiments, or where funding for large-scale experiments is not available. We demonstrate that assessment of plasma, ascites, and urine miRNAs expression may represent a feasible method to explore the potential for finding novel diagnostic, predictive, and prognostic biomarkers for various diseases.


Assuntos
Líquidos Corporais , MicroRNA Circulante , MicroRNAs , Feminino , Humanos , MicroRNAs/genética , Ascite , Seguimentos , Biomarcadores , Líquidos Corporais/metabolismo , Plasma/química , Biomarcadores Tumorais
15.
Anal Bioanal Chem ; 415(5): 935-951, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36598539

RESUMO

Direct infusion of lipid extracts into the ion source of a mass spectrometer is a well-established method for lipid analysis. In most cases, nanofluidic devices are used for sample introduction. However, flow injection analysis (FIA) based on sample infusion from a chromatographic pump can offer a simple alternative to shotgun-based approaches. Here, we describe important modification of a method based on FIA and tandem mass spectrometry (MS/MS). We focus on minimizing contamination of the FIA/MS both to render the lipidomic platform more robust and to increase its capacity and applicability for long-sequence measurements required in clinical applications. Robust validation of the developed method confirms its suitability for lipid quantitation in human plasma analysis. Measurements of standard human plasma reference material (NIST SRM 1950) and a set of plasma samples collected from kidney cancer patients and from healthy volunteers yielded highly similar results between FIA-MS/MS and ultra-high-performance supercritical fluid chromatography (UHPSFC)/MS, thereby demonstrating that all modifications have practically no effect on the statistical output. Newly modified FIA-MS/MS allows for the quantitation of 141 lipid species in plasma (11 major lipid classes) within 5.7 min. Finally, we tested the method in a clinical laboratory of the General University Hospital in Prague. In the clinical setting, the method capacity reached 257 samples/day. We also show similar performance of the classification models trained based on the results obtained in clinical settings and the analytical laboratory at the University of Pardubice. Together, these findings demonstrate the high potential of the modified FIA-MS/MS for application in clinical laboratories to measure plasma and serum lipid profiles.


Assuntos
Lipidômica , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Lipidômica/métodos , Análise de Injeção de Fluxo , Plasma/química , Lipídeos/análise
16.
Biomacromolecules ; 24(2): 766-774, 2023 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-36627763

RESUMO

Heparin, an anionic biomacromolecule, is routinely used as an anticoagulant during medical surgery to prevent blood clot formation and in the treatment of several heart, lung, and circulatory disorders having a higher risk of blood clotting. We herein report supramolecular polymeric nanoassemblies of cationic pyrene-tagged bis-imidazolium amphiphiles for heparin detection with high sensitivity and selectivity in aqueous buffer, plasma, and serum media. The nano-assemblies exhibited cyan-green excimeric emission in aqueous media, and their multivalent array of positive surface charges allowed them to form co-assemblies with heparin, resulting in significantly enhanced emission. This provided a convenient method for heparin detection in buffer at nanomolar concentrations, and most notably, a ratiometric fluorescence response was obtained even in highly competitive 100% human serum and 100% human plasma in a clinically relevant concentration range. Moreover, using the heparin-based luminescent co-assemblies, protamine sulfate, a clinically administered antidote to heparin, was also detected in 100% human serum and 100% human plasma at sub-micromolar concentrations.


Assuntos
Análise Química do Sangue , Heparina , Protaminas , Humanos , Anticoagulantes/farmacologia , Coagulação Sanguínea , Heparina/análise , Heparina/farmacologia , Luminescência , Polímeros/farmacologia , Protaminas/análise , Protaminas/farmacologia , Análise Química do Sangue/métodos , Soro/química , Plasma/química , Soluções Tampão
17.
Anal Chim Acta ; 1239: 340641, 2023 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-36628743

RESUMO

The growing interest in lab-on-a-chip systems for plasma separation has led to the presentation of various devices. Trench-based devices benefiting from gravitational sedimentation are efficient structures with air-locking and low speed-drawbacks. The present study introduces a fast, hemolysis-free, highly efficient blood plasma separation microfluidic device. The proposed device is based on gravitational sedimentation combined with dielectrophoresis force to promote the purity of the separated plasma, reduce the separation process time, and overcome the air-locking problem. The effect of geometrical parameters on the separation process is investigated using finite element analysis to attain optimal design specifications. A drop of whole blood (10 µl) is injected into the fabricated chip at four flow rates of 70 nl/s to 100 nl/s. It takes less than 4 min to obtain 2.2 µl plasma from undiluted blood without losing plasma proteins. Additionally, a porous Melt-Blown Polypropylene (MBPP) layer is used to eliminate the air-locking problem, which in previous trench-based microsystems led to time-consuming device preparation steps. Blood samples with various hematocrits (15%-65%) are tested with the applied voltages of 0-20 Vpp through the optimized structure. A purity of 99.98% ± 0.02% (evaluated by hemocytometry) is achieved using optimized dielectrophoresis force by the applied voltage of 20 Vpp, which is more than the previous studies. The UV-Visible spectroscopy results confirm obtaining a non-hemolyzed sample at a flow rate of 70 nl/s. The proposed device achieves a relative increase in the flow rate compared to similar previous studies while maintaining the high quality of the separated plasma. This achievement lies in using the MBPP layer and combining two separation methods.


Assuntos
Técnicas Analíticas Microfluídicas , Plasma/química , Hematócrito , Proteínas Sanguíneas/análise , Dispositivos Lab-On-A-Chip
18.
Anal Chem ; 95(5): 2812-2821, 2023 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-36625718

RESUMO

Exosomes are an emerging source for disease biomarker discovery due to the high stability of proteins protected by phospholipid bilayers. However, liquid biopsy with exosomes remains challenging due to the extreme complexity of biological samples. Herein, we introduced an amphiphile-dendrimer supramolecular probe (ADSP) for the efficient capture and high-throughput analysis of exosomes, enabling the array-based assay for marker proteins. Amphiphilic amphotericin B was functionalized onto highly branched globular dendrimers, which can then insert into the exosome membrane efficiently, forming a supramolecular complex through multivalent interactions between the probe and the bilayer of exosomes. The ADSP can be easily coated onto magnetic beads or the nitrocellulose membrane, facilitating the capture of exosomes from a minimum amount of clinical samples. The captured exosomes can be detected with target protein antibodies via Western blotting or in a high-throughput array-based dot blotting format. This new strategy exhibited excellent extraction capability from trace body fluids with superior sensitivity (less than 1 µL plasma), good quantitation ability (R2 > 0.99), and high throughput (96 samples in one batch) using clinical plasma samples. The combination of proteomics and ADSP will provide a platform for the discovery and validation of protein biomarkers for cancer diagnosis and prognosis.


Assuntos
Exossomos , Exossomos/química , Biomarcadores/metabolismo , Proteínas/metabolismo , Western Blotting , Plasma/química , Biomarcadores Tumorais/análise
19.
J Sep Sci ; 45(24): 4397-4406, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36271738

RESUMO

An active substance of pyrano[3,2-a]phenazine, also called CPUL1, is a synthesized phenazine derivative and displays broad-spectrum anticancer activities. Quantitative assessment of CPUL1 in biological samples has not been well established, hindering pharmaceutical development and application. According to international guidelines, a sensitive and selective liquid chromatography-tandem mass spectrometry method in negative ion mode was developed and validated for quantification of CPUL1 in human plasma, colorectal cancer cell lines, and rat plasma, whereby linearity and accuracy were demonstrated for the range of 1-1000 ng/ml. The validated liquid chromatography-tandem mass spectrometry method was successfully employed in pharmacokinetic studies of CPUL1 in vitro and in vivo. Notably, the cellular pharmacokinetic behavior of CPUL1 varies in colorectal cancer cell lines. Regarding the pharmacokinetic processes in vivo, oral absorption was less effective than an injection, with a bioavailability of 23.66%. CPUL1 was linearly eliminated after a single administration; however, it could accumulate in tissues (heart, liver, spleen, lung, and kidney) after multiple injections. In summary, this study established a capable bioanalytical method for CPUL1 and provided exploratory pharmacokinetic data, paving the way for use of this promising derivative in disease models.


Assuntos
Neoplasias Colorretais , Espectrometria de Massas em Tandem , Ratos , Humanos , Animais , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Plasma/química , Fenazinas/análise , Cromatografia Líquida de Alta Pressão/métodos , Reprodutibilidade dos Testes
20.
Int J Mol Sci ; 23(15)2022 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-35955896

RESUMO

Early pregnancy loss (EPL) is a relatively common pathology of which almost 50% of cases remain idiopathic. In the search for novel biomarkers, differential scanning calorimetry (DSC) is intensively used to characterize the thermodynamic behavior of blood plasma/serum proteome in health and disease. Herein, for the first time, we investigate the DSC denaturation profiles of blood plasma derived from patients suffering EPL compared to healthy pregnant and non-pregnant women. Data analysis reveals that 58% of the EPL thermograms differ significantly from those of healthy pregnant women. Thermal stabilization of a fraction of albumin-assigned transition with concomitant suppression of the major and enhancement of the globulin-assigned transition are characteristic features of EPL calorimetric profiles that could be used as a new indicator of a risk pregnancy. The presented results suggest an altered composition or intermolecular interactions of the plasma proteome of women with EPL. In addition, the alterations of the EPL thermograms correlate with the increased blood levels of tumor necrosis factor-α (TNF-α) and interleukin-6 (IL-6) and a higher prevalence of the polymorphism in the plasminogen activator inhibitor type-1 (PAI-1) gene, suggesting an expression of an overall enhanced immune response. The concomitant changes in plasma thermograms confirm the potential of the DSC approach for distinguishing changes in the pathological state of the blood plasma proteome.


Assuntos
Aborto Espontâneo , Proteoma , Varredura Diferencial de Calorimetria , Citocinas/genética , Feminino , Genótipo , Humanos , Plasma/química , Inibidor 1 de Ativador de Plasminogênio/genética , Gravidez , Proteoma/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA