Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 592
Filtrar
1.
Biomolecules ; 14(4)2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38672522

RESUMO

In this study, we introduce electrospun polydioxanone (PDO) nonwoven fabrics as a platform for the delivery of adeno-associated virus (AAV) vectors for transduction and genome editing by adhering them to organ surfaces, including the heart. AAV vectors were loaded onto the PDO fabrics by soaking the fabrics in a solution containing AAV vectors. In vitro, the amount of AAV vectors loaded onto the fabrics could be adjusted by changing their concentration in the solution, and the number of cells expressing the green fluorescent protein (GFP) encoded by the AAV vectors increased in correlation with the increasing amount of loaded AAV vectors. In vivo, both transduction and genome editing resulted in the observation of GFP expression around AAV vector-loaded PDO fabrics attached to the surfaces of mouse hearts, indicating effective transduction and expression at the target site. These results demonstrate the great potential of electrospun PDO nonwoven fabrics carrying therapeutic AAV vectors for gene therapy.


Assuntos
Dependovirus , Edição de Genes , Vetores Genéticos , Polidioxanona , Dependovirus/genética , Animais , Vetores Genéticos/genética , Polidioxanona/química , Edição de Genes/métodos , Camundongos , Humanos , Transdução Genética/métodos , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo , Células HEK293 , Terapia Genética/métodos , Miocárdio/metabolismo
2.
Aesthetic Plast Surg ; 48(9): 1706-1714, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38519570

RESUMO

BACKGROUND: Traditional facial aging surgeries have risks and extended recovery times, leading to a demand for minimally invasive alternatives. PDO (polydioxanone) threads, which are absorbable sutures that stimulate collagen production and tissue contraction, offer improved aesthetic outcomes. This paper evaluates the combined use of PDO thread mid-cheek lift and lower blepharoplasty for facial rejuvenation. METHODS: This retrospective study compared outcomes in patients undergoing lower blepharoplasty combined with a mid-face lift using PDO threads versus those undergoing only lower blepharoplasty. Focused on individuals with baggy lower eyelids and pronounced nasolabial folds, outcome measures included the Modified Fitzpatrick wrinkle scale, Allergan® midface volume deficit scale, Width of inter zygomatic distance, Patient and Observer Scar Assessment Scale, and patient satisfaction questionnaires, assessed at baseline, 3 months, and 1 year postoperatively. RESULTS: The combined procedure demonstrated superior aesthetic outcomes and higher patient satisfaction compared to lower blepharoplasty alone. Improvements were more significant in wrinkle reduction, midface volume, and inter-zygomatic distance in the combined procedure group. Although the combined procedure had a longer mean operation time, scar assessment scores were similar between both groups, with no complications reported. CONCLUSION: The combination of lower blepharoplasty and mid-face lift using PDO threads is a comprehensive and effective approach for facial rejuvenation. It significantly enhances wrinkle reduction, mid-face lifting, and patient satisfaction. Ultrasound-guided thread lifting, a method of assessing and performing mid-face lifting, proves to be safe and efficient. This approach holds promise as a future option in cosmetic anti-aging surgery, presenting a minimally invasive alternative with natural-looking results and reduced downtime. LEVEL OF EVIDENCE II: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors https://link.springer.com/journal/00266 .


Assuntos
Blefaroplastia , Satisfação do Paciente , Polidioxanona , Rejuvenescimento , Ritidoplastia , Envelhecimento da Pele , Humanos , Blefaroplastia/métodos , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Ritidoplastia/métodos , Masculino , Resultado do Tratamento , Estética , Idoso , Adulto , Técnicas de Sutura , Suturas , Estudos de Coortes
3.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38471110

RESUMO

OBJECTIVES: To evaluate the biologic impact of polydioxanone (PDO) stenting in an animal model of inflammatory tracheal stenosis (TS). Additionally, to compare these results with those obtained in the same model without a stent and after placing one PDO stent in a healthy trachea. METHODS: 40 adult NZ rabbits were distributed into 3 groups: Group A, 8 animals with a healthy trachea and a PDO stent; group B, 17 rabbits with a TS and no stent; and group C, 15 animals with TS and a PDO stent. Histopathological studies included Masson's trichrome staining for submucosal fibrosis and Safranin O to assess structural integrity of cartilage. Morphometric analyses were performed in the 3 groups. RESULTS: Stent placement was successful in every case. Histological studies did not show a significant increase in tracheal wall collagen area and cartilage structure was not modified in those rabbits with a PDO stent, even in a TS scenario. Stent implantation permitted recovery of normal tracheal lumen levels in the TS model. CONCLUSIONS: PDO stenting in the normal trachea and in a model of TS neither caused increase in the collagen matrix nor modification of the cartilaginous support. Additionally, radial force exhibited by PDO stents was effective in restoring normal tracheal lumen when placed in a stenotic lesion. These findings suggest that they may be safe and useful in the setting of an acquired TS.


Assuntos
Estenose Traqueal , Animais , Coelhos , Estenose Traqueal/cirurgia , Polidioxanona , Traqueia/cirurgia , Modelos Teóricos , Stents , Colágeno
5.
Dermatol Surg ; 50(4): 360-365, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38318968

RESUMO

BACKGROUND: Using a thread for wound closure promotes healing and minimizes contamination by foreign substances. Threads have also been employed in esthetic surgery; however, functional threads that can improve wrinkles and rejuvenate the skin are required. OBJECTIVE: To evaluate the suitability of polydioxanone threads coated with polyethylene glycol, hyaluronic acid, and amino acids for use in the medical field because such formulations are expected to promote regeneration and collagen synthesis. MATERIALS AND METHODS: Physical properties (diameter [ n = 20], tensile strength [ n = 20], strength retention rate [ n = 10], and scanning electron microscopy images) and cytotoxicity (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide and lactate dehydrogenase assays) of polydioxanone threads coated with polyethylene glycol, hyaluronic acid, and amino acids were assessed and compared with those of uncoated polydioxanone threads. Analyses were performed using IBM SPSS Statistics (Statistical significance; p values <.05). RESULTS: The size standards for tensile strength (≥63.5 N) and diameter (average 0.570-0.610 mm) were met. There were no differences in the physical properties of the coated and uncoated threads; however, the biocompatibility of coated threads was high owing to low cytotoxicity. CONCLUSION: Threads coated with materials that can promote regeneration are suitable for use in the medical field.


Assuntos
Polidioxanona , Ritidoplastia , Humanos , Ácido Hialurônico , Ritidoplastia/métodos , Aminoácidos , Polietilenoglicóis , Suturas
6.
Tissue Eng Part C Methods ; 30(3): 102-112, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38271574

RESUMO

The aim of this study was to assess the bone regeneration potential of a polydioxanone (PDO) scaffold together with recombinant human bone morphogenetic protein-2 (rhBMP-2) for the reconstruction of large bone defect. In total, 24 male rats (6 months old) were subjected to bilateral femoral stabilization using titanium plates to create a 2 mm gap, and reconstruction using rhBMP-2 (Infuse®; 3.25 µg). The bone defects were covered with PDO (PDO group), or with titanium mesh (Ti group). Animals were euthanized on days 14 and 60. Simultaneously, 16 rats received PDO and Ti in their dorsum for the purpose of biocompatibility analysis at 3, 5, 7, and 10 days postoperatively. X-ray densitometry showed a higher density in the PDO group on day 14. On day 60, coverage of the bone defect with PDO showed a larger quantity of newly formed bone than that found for the Ti group, a lower inflammatory infiltrate value, and a more significant number of blood vessels on day 14. By immunohistochemical assessment, runt-related transcription factor 2 (RUNX2) and osteocalcin (OCN) showed higher labeling on day 14 in the PDO group. On day 60, bone morphogenetic protein-2 (BMP-2) showed higher labeling in the PDO group, whereas Ti showed higher labeling for osteoprotegerin, nuclear factor kappa B ligand-activating receptor, RUNX2, and OCN. Furthermore, biocompatibility analysis showed a higher inflammatory response in the Ti group. The PDO scaffold enhanced bone regeneration when associated with rhBMP-2 in rat femur reconstruction. Impact statement Regeneration of segmental bone defects is a difficult task, and several techniques and materials have been used. Recent advances in the production of synthetic polymers, such as polydioxanone (PDO), produced by three-dimensional printing, have shown distinct characteristics that could improve tissue regeneration even in an important bone defect. The present preclinical study showed that PDO membranes used as scaffolds to carry recombinant human bone morphogenetic protein-2 (rhBMP-2) improved bone tissue regeneration by more than 8-fold when compared with titanium mesh, suggesting that PDO membranes could be a feasible and useful material for use in guided bone regeneration. (In English, viable is only used for living creatures capable of sustaining life.


Assuntos
Subunidade alfa 1 de Fator de Ligação ao Core , Polidioxanona , Masculino , Ratos , Humanos , Animais , Lactente , Polidioxanona/farmacologia , Titânio , Proteína Morfogenética Óssea 2/farmacologia , Fator de Crescimento Transformador beta/farmacologia , Regeneração Óssea , Proteínas Recombinantes/farmacologia , Fêmur/diagnóstico por imagem
7.
Hernia ; 28(2): 527-535, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38212505

RESUMO

PURPOSE: Using small instead of large bites for laparotomy closure results in lower incidence of incisional hernia, but no consensus exists on which suture material to use. This study aimed to compare five different closure strategies in a standardized experimental setting. METHODS: Fifty porcine abdominal walls were arranged into 5 groups: (A) running 2/0 polydioxanone; (B) interlocking 2/0 polydioxanone; (C) running size 0 barbed polydioxanone; (D) running size 0 barbed glycolic acid and trimethylene carbonate; (E) running size 0 suturable polypropylene mesh. The small-bites technique was used for linea alba closure in all. The abdominal walls were divided into a supra- and infra-umbilical half, resulting in 20 specimens per group that were pulled apart in a tensile testing machine. Maximum tensile force and types of suture failure were registered. RESULTS: The highest tensile force was measured when using barbed polydioxanone (334.8 N ± 157.0), but differences did not reach statistical significance. Infra-umbilical abdominal walls endured a significantly higher maximum tensile force compared to supra-umbilical (397 N vs 271 N, p < 0.001). Barbed glycolic acid and trimethylene carbonate failed significantly more often (25% vs 0%, p = 0.008). CONCLUSION: Based on tensile force, both interlocking and running suture techniques using polydioxanone, and running sutures using barbed polydioxanone or suturable mesh, seem to be suitable for abdominal wall closure. Tensile strength was significantly higher in infra-umbilical abdominal walls compared to supra-umbilical. Barbed glycolic acid and trimethylene carbonate should probably be discouraged for fascial closure, because of increased risk of suture failure.


Assuntos
Parede Abdominal , Técnicas de Fechamento de Ferimentos Abdominais , Glicolatos , Suínos , Animais , Parede Abdominal/cirurgia , Polidioxanona , Herniorrafia , Técnicas de Sutura/efeitos adversos , Modelos Animais , Resistência à Tração , Laparotomia , Suturas , Técnicas de Fechamento de Ferimentos Abdominais/efeitos adversos
8.
Int J Biol Macromol ; 259(Pt 1): 129218, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38185297

RESUMO

Nanofibers for drug delivery systems have gained much attention during the past years. This paper describes for the first time the loading of a bioactive precipitate (JAD) from the marine sponge Jaspis diastra in PDX and fucoidan-PDX. JAD was characterized by LC-MS/MS and the major component was jaspamide (1) with a purity of 62.66 %. The cytotoxicity of JAD was compared with paclitaxel (PTX). JAD and PTX displayed IC50 values of 1.10 ± 0.7 µg/mL and 0.21 ± 0.12 µg/mL on skin fibroblasts L929 cells whilst their IC50 values on uveal MP41 cancer cells, were 2.10 ± 0.55 µg/mL and 1.38 ± 0.68 µg/mL, respectively. JAD was found to be less cytotoxic to healthy fibroblasts compared to PTX. JAD and PTX loaded scaffolds showed sustained release over 96 h in physiological medium which is likely to reduce the secondary cytotoxic effect induced by JAD and PTX alone. The physico-chemical properties of the loaded and unloaded scaffolds together with their degradation and action on tumor microenvironment by using L929 and MP41 cells were investigated. JAD and PTX at a concentration of 0.5 % (drug/polymer, w/w) in the electrospun mats prevented growth and proliferation of L929 and MP41 cells. Co-culture of L929 and MP41 showed that the JAD and PTX loaded mats inhibited the growth of both cells and caused cell death.


Assuntos
Antineoplásicos , Nanofibras , Neoplasias , Polissacarídeos , Poríferos , Animais , Paclitaxel/farmacologia , Paclitaxel/química , Polidioxanona/química , Nanofibras/química , Cromatografia Líquida , Espectrometria de Massas em Tandem , Antineoplásicos/farmacologia , Linhagem Celular Tumoral , Microambiente Tumoral
9.
Medicina (Kaunas) ; 60(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38256351

RESUMO

Objective: To compare the vaginal cuff dehiscence (VCD) rates using Vicryl (Poliglactyn 910) and Polydioxanone (PDS) in patients who underwent laparoscopic hysterectomy. Materials and methods: A retrospective, monocentric study was conducted, including all patients undergoing laparoscopic hysterectomy at the Department of Obstetrics and Gynaecology, Azienda di Rilievo Nazionale e di Alta Specializzazione (ARNAS) Garibaldi Nesima, Catania, between January 2014 and December 2021. Patients underwent hysterectomy for benign gynecologic pathologies (endometriosis, leiomyomas, or benign pelvic pathologies) or malignant gynecologic pathologies (endometrium cancer, complex endometrial hyperplasia, ovarian cancer, cervix cancer, or uterine carcinosarcoma). The Z-score calculation was performed to find eventual statistically significant differences between the two populations regarding VCD rates. Results: Laparoscopic vaginal cuff closure was performed, with Vicryl sutures in 202 patients and PDS sutures in 184 women. Demographic and baseline characteristics were not significantly different in the two groups. VCD occurred in three patients in the Vicryl group and did not occur in the PDS group. The three cases of VCD were precipitated by intercourses that occurred within 90 days of surgery. However, there was not a significant statistical difference between the two groups regarding VCD (p = 0.09). Conclusions: Vicryl and PDS sutures seem to be similar for vaginal cuff closure in laparoscopic hysterectomy. The VCD rate was low, and the observed differences between the Vicryl and PDS groups did not reach statistical significance. Further research through prospective studies is essential.


Assuntos
Laparoscopia , Polidioxanona , Gravidez , Feminino , Humanos , Polidioxanona/uso terapêutico , Poliglactina 910/uso terapêutico , Estudos Prospectivos , Estudos Retrospectivos , Laparoscopia/efeitos adversos , Histerectomia/efeitos adversos
10.
Dermatol Surg ; 50(2): 206-207, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37815504
11.
Aesthetic Plast Surg ; 48(2): 221-227, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37644191

RESUMO

INTRODUCTION: Although various products are commonly used for skin rejuvenation, solid-type hyaluronic acid (HA) as an injectable form has not been researched or utilized. This study aimed to demonstrate the safety and efficacy of solid-type HA in thread form, which differs from the conventional gel-type HA commonly used. METHOD: Solid-type HA threads, conventional HA fillers, and polydioxanone (PDO) threads were inserted into the dorsal subcutaneous layer of mice. Photographs were taken on days 0, 1, 3, and 7, and on day 7, the samples were harvested for histological analysis. Inflammatory reactions and detection of collagen were confirmed through tissue staining, and real-time PCR was conducted to quantify collagen synthesis. RESULTS: In the histological analysis, the PDO threads exhibited a greater inflammatory response compared to the HA threads. Masson's trichrome staining revealed a higher degree of collagen synthesis in the HA thread group compared to the HA filler group. While collagen type 1 expression was significantly higher in the PDO thread group than in the HA thread group, the HA thread group showed higher expression levels of collagen type 3. Furthermore, the PDO thread group demonstrated a statistically significant increase in TGF-ß1 compared to the HA group. CONCLUSION: This in vivo study demonstrated the stable application of solid-type pure HA threads and their potential for inducing collagen production, while also yielding a low inflammatory response. The findings highlight the promising applications of solid-type HA in the field of cosmetic dermatology. NO LEVEL ASSIGNED: This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Preenchedores Dérmicos , Camundongos , Animais , Preenchedores Dérmicos/efeitos adversos , Polidioxanona , Ácido Hialurônico/efeitos adversos , Pele , Colágeno
12.
Adv Sci (Weinh) ; 11(2): e2305967, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37984880

RESUMO

Transcatheter intervention has been the preferred treatment for congenital structural heart diseases by implanting occluders into the heart defect site through minimally invasive access. Biodegradable polymers provide a promising alternative for cardiovascular implants by conferring therapeutic function and eliminating long-term complications, but inducing in situ cardiac tissue regeneration remains a substantial clinical challenge. PGAG (polydioxanone/poly (l-lactic acid)-gelatin-A5G81) occluders are prepared by covalently conjugating biomolecules composed of gelatin and layer adhesive protein-derived peptides (A5G81) to the surface of polydioxanone and poly (l-lactic acid) fibers. The polymer microfiber-biomacromolecule-peptide frame with biophysical and biochemical cues could orchestrate the biomaterial-host cell interactions, by recruiting endogenous endothelial cells, promoting their adhesion and proliferation, and polarizing immune cells into anti-inflammatory phenotypes and augmenting the release of reparative cytokines. In a porcine atrial septal defect (ASD) model, PGAG occluders promote in situ tissue regeneration by accelerating surface endothelialization and regulating immune response, which mitigate inflammation and fibrosis formation, and facilitate the fusion of occluder with surrounding heart tissue. Collectively, this work highlights the modulation of cell-biomaterial interactions for tissue regeneration in cardiac defect models, ensuring endothelialization and extracellular matrix remodeling on polymeric scaffolds. Bioinspired cell-material interface offers a highly efficient and generalized approach for constructing bioactive coatings on medical devices.


Assuntos
Gelatina , Dispositivo para Oclusão Septal , Animais , Suínos , Gelatina/química , Polidioxanona , Células Endoteliais , Polímeros , Materiais Biocompatíveis , Ácido Láctico , Peptídeos
13.
Aesthetic Plast Surg ; 48(5): 878-883, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38148359

RESUMO

BACKGROUND: Lower lateral cartilage reshaping is one of the basic steps in rhinoplasty. Hemitransdomal suture is frequently used for dome narrowing. Different suture materials can be used for hemitransdomal suture. In this study, we investigated the effectiveness of polypropylene and polydioxanone in hemitransdomal suture by designing a new experimental model in the rabbit ear cartilage. METHODS: Twelve young adult male New Zealand White rabbits were used. The bipedicled inverted-U-shaped cartilage was elevated in each ear of the rabbits. Two hemitransdomal sutures were applied using 5-0 polypropylene on one ear and 5-0 polydioxanone on the other ear randomly. A 5 mm high cartilage mound was created with two hemitransdomal sutures on each side. The sample size was twelve both in the polypropylene group and the polydioxanone group (n = 12). All animals were sacrificed after three months. Cartilage mound heights were measured. The samples were examined histologically regarding fibroadipose tissue, inflammation, foreign body granuloma, cartilage degeneration, and the presence of inclusion cyst. RESULTS: Cartilage mound height was significantly higher in the polypropylene group than in the polydioxanone group at the end of the third month [3.75 mm (± 0.68) vs. 3.03 mm (± 0.69); p < 0.05]. There was no significant difference between the two groups in histological analysis (p > 0.05). CONCLUSIONS: Polypropylene suture may be more effective in maintaining the shape given to the dome by hemitransdomal sutures in rhinoplasty. No Level Assigned This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to Table of Contents or the online Instructions to Authors www.springer.com/00266.


Assuntos
Cartilagem da Orelha , Rinoplastia , Coelhos , Masculino , Animais , Cartilagem da Orelha/cirurgia , Polidioxanona , Polipropilenos , Suturas
14.
Acta Vet Scand ; 65(1): 48, 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37986118

RESUMO

BACKGROUND: A 3D printed self-locking device made of polydioxanone (PDO) was developed to facilitate a standardized ligation technique. The subcutaneous tissue reaction to the device was evaluated after implantation in ten horses of mixed age, sex and breed and compared to loops of poly(lactic-co-glycolic acid) (PLGA). In two of the horses, the implants were removed before closing the skin. The appearance of the implants and surrounding tissue was followed over time using ultrasonography. Implants were removed after 10 and 27 (± 1) days for histologic examination. RESULTS: On macroscopic inspection at day 10, the PDO-device was fragmented and the surrounding tissue was oedematous. On ultrasonographic examination, the device was seen as a hyperechoic structure with strong acoustic shadowing that could be detected 4 months post-implantation, but not at 7 months. Histology revealed a transient granulomatous inflammation, i.e., a foreign body reaction, which surrounded both PDO and PLGA implants. The type and intensity of the inflammation varied between individuals and tissue category. CONCLUSIONS: The 3D printed PDO-device caused a transient inflammatory reaction in the subcutaneous tissue and complete resorption occurred between 4 and 7 months. Considering the intended use as a ligation device the early fragmentation warrants further adjustments of both material and the 3D printing process before the device can be used in a clinical setting.


Assuntos
Doenças dos Cavalos , Polidioxanona , Animais , Cavalos/cirurgia , Inflamação/veterinária , Ligadura/métodos , Ligadura/veterinária , Impressão Tridimensional , Tela Subcutânea/cirurgia , Masculino , Feminino
15.
Vet Surg ; 52(8): 1121-1127, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37655506

RESUMO

OBJECTIVE: To evaluate the use of bidirectional knotless barbed suture material for closure of the equine linea alba. STUDY DESIGN: Laboratory study. ANIMAL OR SAMPLE POPULATION: Adult light horse cadavers (n = 24). METHODS: A 25 cm incision was made through the linea alba, and a 200 L polyurethane bladder was positioned within the abdomen. The linea alba was closed either using USP2/EP5 bidirectional polydioxanone barbed suture or USP2/EP5 standard polydioxanone suture in a simple continuous pattern. Closure time was recorded for each suture type. The bladder was air-insufflated at 40 L/min, and the pressure at body wall failure recorded. The length of suture used for wound closure and wound failure modes were recorded. Suture length, closure time, bursting pressure, and failure modes were compared using Welch-Aspin t-tests. RESULTS: The incisional bursting pressure was comparable between the two groups (p > .05). Less suture material (p < .01) was required with the barbed suture than the standard suture. Closure time was less for the barbed suture than the standard suture (p < .01). Suture failure was the main failure mode in both groups (83% cases). CONCLUSIONS: Closure of the equine linea alba using bidirectional barbed suture material reduced the amount of foreign material in the wound and decreased closure time without compromising incisional strength. CLINICAL RELEVANCE: Bidirectional barbed suture material could be considered as an alternative to standard suture materials for closure of the equine line alba.


Assuntos
Parede Abdominal , Doenças dos Cavalos , Ferida Cirúrgica , Cavalos/cirurgia , Animais , Polidioxanona , Técnicas de Sutura/veterinária , Ferida Cirúrgica/veterinária , Suturas/veterinária
16.
Clin Plast Surg ; 50(3): 465-477, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37169412

RESUMO

Cosmetic procedures to combat the effects of aging are increasing in demand. Surgical interventions, such as rhytidectomy, have long been the standard method of providing a more youthful appearance. However, these procedures are costly, often require general anesthesia, and have potential risks such as scarring and prolonged recovery. A safe, effective, alternative to surgery is the nonsurgical thread-lift. Nevertheless, proper patient selection is critical for optimal outcomes and for patient and provider satisfaction. Over the past decade, these treatments have gained significant popularity for patients to achieve a more rejuvenated appearance with less complications and minimal downtime.


Assuntos
Ritidoplastia , Envelhecimento da Pele , Humanos , Polidioxanona , Rejuvenescimento , Face/cirurgia , Ritidoplastia/métodos
17.
BJU Int ; 132(1): 109-111, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36919248

RESUMO

OBJECTIVE: To outline our step-by-step surgical technique for a transurethral ventral buccal mucosa graft inlay urethroplasty to treat fossa navicularis and distal urethral strictures. METHODS: The transurethral ventral inlay urethroplasty is accomplished in four steps. First, after obtaining proper exposure the cicatrice is excised via a transurethral ventral urethrotomy until the lumen is at least 24fr. Second, double arm 6-0 polydioxanone suture is used to deliver the triangular buccal mucosal graft to the proximal extent of the urethrotomy and secured externally. Third, the graft is secured to the meatus with 5-0 polyglactin sutures and additional 6-0 double arm polydioxanone sutures are used to quilt the graft for spread fixation. Finally, a 16fr silicone catheter is placed. Patients are discharged the same day and return for void trial after one week. A retrospective, single institution review was conducted to include all patients who underwent this procedure with a minimum of 1 year follow-up. Patients were analyzed for recurrences, and pre- and post-operative urine flow rates, post void residuals, and patient questionnaires were also reviewed. RESULTS: 44 patients met our inclusion criteria. Median surgical time was 120 minutes. At a mean follow up of 36 months (IQR 22-50) 95% of patients are patent without additional interventions. The 2 patients that did have stricture recurrence were found to have urethral stenosis that extended more proximally, and both were successfully treated with a dorsal onlay buccal urethroplasty. There were significant improvements in urine flow rate, post void residuals, international prostate symptom score and quality of life scores post operatively. There was no difference in post operative sexual function scores. CONCLUSION: This minimally invasive transurethral ventral urethroplasty has excellent intermediate term outcomes in terms of traditional objective measures of urethroplasty success and patient reported outcomes.


Assuntos
Mucosa Bucal , Estreitamento Uretral , Masculino , Humanos , Mucosa Bucal/transplante , Estudos Retrospectivos , Polidioxanona , Qualidade de Vida , Procedimentos Cirúrgicos Urológicos Masculinos/métodos , Uretra/cirurgia , Estreitamento Uretral/cirurgia , Resultado do Tratamento
18.
World J Surg ; 47(2): 448-454, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36316513

RESUMO

INTRODUCTION: Topical agents are sometimes applied to surgical wounds after closure; these may include antiseptics or antibiotics. Minimal research has been undertaken to investigate the effect of topical regimens on the tensile strength of suture materials. AIM: To investigate the effect of four commonly used wound care regimens on the tensile strength of suture materials. METHODS: The failure load of 9 different suture materials was tested using the Instron Electroplus E3000 tensile testing machine (Instron Corporation, Norwood, Massachusetts). Tensile strength was represented as the failure load, measured in Newtons (N), and defined as the maximal load that could be applied across the suture prior to failure. Each suture was tested dry and after immersion in one of 4 products for 7 days and tested on day 7. The immersion agents tested were: sodium chloride 0.9%, MicroSafe® (Sonoma Pharmaceuticals, Petaluma, CA), Aqueous Povidone-iodine 10% solution (Betadine-Mundipharma), and Fucidin ointment. RESULTS: Sodium chloride 0.9%, MicroSafe®, Aqueous Povidone-iodine 10%, and Fucidin seem to increase the failure load of most absorbable and non-absorbable sutures. However, the failure load of Polyglactin 910 suture (Surgilactin, coated, violet-Ethicon) is reduced by long-term exposure to either sodium chloride 0.9% or MicroSafe®, while the failure load of the Polydioxanone suture (PDS Plus-Ethicon) is reduced by long-term exposure to MicroSafe® only. CONCLUSION: In our experiment, the commonly used wound care products have been shown to alter the tensile strength of suture materials. Further human studies are required to ascertain the clinical validity and applicability of our findings.


Assuntos
Povidona-Iodo , Cloreto de Sódio , Humanos , Teste de Materiais , Resistência à Tração , Polidioxanona , Suturas , Técnicas de Sutura
20.
Surg Innov ; 30(2): 150-157, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35687856

RESUMO

BACKGROUND: Colorectal anastomotic leaks remain one of the most significant complications following colorectal surgery. Various interventions to reduce anastomotic leaks have been investigated, however few have resulted in a significant improvement. To date antiseptic coated monofilament sutures for sutured bowel anastomoses have not been assessed, hence this study was undertaken to investigate whether or not triclosan impregnated polydioxanone suture material (PDS) results in fewer anastomotic leaks. METHODS: A rabbit colo-colonic anastomotic model was developed to compare the tensile strength and local inflammatory response between triclosan coated PDS and uncoated PDS. RESULTS: Of the 42 anastomoses there were 4 (9.5%) leaks. Of the remaining 38 anastomoses neither the leak pressures, degree of bowel wall inflammation or fibrosis were statistically different (P = .11; .813 and .658 respectively) when comparing the two suture materials. CONCLUSIONS: In an animal model, triclosan coated PDS is as safe as uncoated PDS in performing colo-colonic anastomosis.


Assuntos
Anti-Infecciosos Locais , Triclosan , Animais , Gravidez , Coelhos , Feminino , Anti-Infecciosos Locais/farmacologia , Anti-Infecciosos Locais/uso terapêutico , Fístula Anastomótica/prevenção & controle , Triclosan/farmacologia , Anastomose Cirúrgica , Polidioxanona , Suturas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA