Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 182
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39140312

RESUMO

Infective endocarditis, particularly after implanting valve prostheses, poses significant surgical challenges, often requiring complex interventions. We describe a case of a 37-year-old male with Staphylococcus aureus endocarditis, unsuccessfully treated with mechanical valve prostheses. Continued infection led to the destruction of the intervalvular fibrous body, necessitating a Commando procedure involving radical debridement and replacement of both aortic and mitral valves with complex patch reconstruction. Prosthesis selection remains contentious, considering recurrence risk and long-term prognosis. Our case underscores timely intervention and meticulous technique in managing such complex situations. It highlights successful strategies for treating infective endocarditis with destruction of aortomitral continuity, emphasizing the pivotal role of the Commando procedure.


Assuntos
Valva Aórtica , Endocardite Bacteriana , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Infecções Estafilocócicas , Humanos , Masculino , Adulto , Endocardite Bacteriana/cirurgia , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/cirurgia , Infecções Estafilocócicas/etiologia , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Mitral/cirurgia , Staphylococcus aureus/isolamento & purificação , Reoperação , Desbridamento/métodos
3.
Diagn Microbiol Infect Dis ; 110(1): 116285, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39018935

RESUMO

Parvimonas micra, a gram-positive anaerobic bacterium, has garnered increased attention due to its role in infective endocarditis. We present a challenging prosthetic valve endocarditis caused by Parvimonas micra in a patient with a complex cardiac history involving multiple surgeries. The case highlights the difficulties in diagnosis and treatment, emphasizing the importance of advanced diagnostic techniques, including metagenomics next-generation sequencing (mNGS). Additionally, it underscores the need for heightened vigilance regarding oral symptoms and the potential risk of bacteremia in post-valvular surgery patients. This report contributes to a better understanding of Parvimonas micra-associated endocarditis and its unique characteristics.


Assuntos
Endocardite Bacteriana , Firmicutes , Infecções por Bactérias Gram-Positivas , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Humanos , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/tratamento farmacológico , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/tratamento farmacológico , Próteses Valvulares Cardíacas/efeitos adversos , Próteses Valvulares Cardíacas/microbiologia , Infecções por Bactérias Gram-Positivas/microbiologia , Infecções por Bactérias Gram-Positivas/diagnóstico , Infecções por Bactérias Gram-Positivas/tratamento farmacológico , Firmicutes/isolamento & purificação , Firmicutes/genética , Masculino , Antibacterianos/uso terapêutico , Sequenciamento de Nucleotídeos em Larga Escala , Pessoa de Meia-Idade
4.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38913864

RESUMO

OBJECTIVES: Evidence on long-term clinical outcomes considering suture-securing techniques used for surgical aortic valve replacement is still uncertain. METHODS: A total of 1405 patients who underwent surgical aortic valve replacement between January 2016 and December 2022 were included and grouped according to the suture-securing technique used (automated titanium fastener versus hand-tied knots). The occurrence of infective endocarditis during follow-up was set as the primary study end-point. As secondary study end-points, stroke, all-cause mortality and a composite outcome of either infective endocarditis, stroke, or all-cause mortality were assessed. RESULTS: The automated titanium fastener was used in 829 (59%) patients, whereas the hand-knot tying technique was used in 576 (41%) patients. The multivariable proportional competing risk regression analysis showed a significantly lower risk of infective endocarditis during follow-up in the automated titanium fastener group (adjusted sub-hazard ratio 0.44, 95% confidence interval 0.20-0.94, P = 0.035). The automated titanium fastener group was not associated with an increased risk of mortality or attaining the composite outcome, respectively (adjusted hazard ratio 0.81, 95% confidence interval 0.60-1.09, P = 0.169; adjusted hazard ratio 0.82, 95% confidence interval 0.63-1.07, P = 0.152). This group was not associated with an increased risk of stroke (adjusted sub-hazard ratio 0.82, 95% confidence interval 0.47-1.45, P = 0.504). Also, a significantly lower rate of early-onset infective endocarditis was observed in the automated titanium fastener group, (0.4% vs 1.4%, P = 0.032). CONCLUSIONS: Suture-securing with an automated titanium fastener device appears to be superior compared to the hand-knot tying technique in terms of lower risk of infective endocarditis.


Assuntos
Valva Aórtica , Endocardite , Implante de Prótese de Valva Cardíaca , Técnicas de Sutura , Titânio , Humanos , Masculino , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Idoso , Valva Aórtica/cirurgia , Endocardite/prevenção & controle , Técnicas de Sutura/instrumentação , Estudos Retrospectivos , Pessoa de Meia-Idade , Próteses Valvulares Cardíacas/efeitos adversos
5.
J Cardiothorac Surg ; 19(1): 380, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38926882

RESUMO

Intra-cardiac thrombosis is a potentially devastating complication of extracorporeal membrane oxygenation (ECMO) mechanical circulatory support. We present here a patient who suffered complete thrombosis of a fresh mitral prosthesis and left atrium in the setting of ECMO with aortic insufficiency who was treated with repeat valve replacement and thrombectomy. To our knowledge, she is the only patient in the reported literature to have survived this complication.


Assuntos
Bioprótese , Oxigenação por Membrana Extracorpórea , Átrios do Coração , Próteses Valvulares Cardíacas , Valva Mitral , Trombose , Feminino , Humanos , Bioprótese/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Mitral/cirurgia , Trombectomia/métodos , Trombose/etiologia , Trombose/cirurgia , Idoso
6.
Indian Heart J ; 76(3): 192-196, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38879396

RESUMO

BACKGROUND: Left-sided mechanical prosthetic heart valve thrombosis (PVT) occurs because of suboptimal anticoagulation and is common in low-resource settings. Urgent surgery and fibrinolytic therapy (FT) are the two treatment options available for this condition. Urgent surgery is a high-risk procedure but results in successful restoration of valve function more often and is the treatment of choice in developed countries. In low-resource countries, FT is used as the default treatment strategy, though it is associated with lower success rates and a higher rate of bleeding and embolic complications. There are no randomized trials comparing the two modalities. METHODS: We performed a single center randomized controlled trial comparing urgent surgery (valve replacement or thrombectomy) with FT (low-dose, slow infusion tissue plasminogen activator, tPA) in patients with symptomatic left-sided PVT. The primary outcome was the occurrence of a complete clinical response, defined as discharge from hospital with completely restored valve function, in the absence of stroke, major bleeding or non-CNS systemic embolism. Outcome assessment was done by investigators blinded to treatment allocation. The principal safety outcome was the occurrence of a composite of in-hospital death, non-fatal stroke, non-fatal major bleed or non-CNS systemic embolism. Outcomes will be assessed both in the intention-to-treat, and in the as-treated population. We will also report outcomes at one year of follow-up. The trial has completed recruitment. CONCLUSION: This is the first randomized trial to compare urgent surgery with FT for the treatment of left-sided PVT. The results will provide evidence to help clinicians make treatment choices for these patients. (Clinical trial registration: CTRI/2017/10/010159).


Assuntos
Próteses Valvulares Cardíacas , Terapia Trombolítica , Trombose , Humanos , Próteses Valvulares Cardíacas/efeitos adversos , Terapia Trombolítica/métodos , Trombose/etiologia , Feminino , Masculino , Fibrinolíticos/uso terapêutico , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Seguimentos , Doenças das Valvas Cardíacas/cirurgia , Resultado do Tratamento , Adulto , Ensaios Clínicos Controlados Aleatórios como Assunto
7.
Kyobu Geka ; 77(5): 361-363, 2024 May.
Artigo em Japonês | MEDLINE | ID: mdl-38720605

RESUMO

Prosthetic valve endocarditis (PVE) is rare but devastating. A 69-year old man admitted for active endocarditis caused by Streptococcus pasteurianus. Antibiotic therapy was started, but the patient developed bowel obstruction owing to cancer with multiple liver metastases, and underwent transverse colectomy. Following colectomy, antibiotic agent was given continued for 4 weeks after and mitral valve replacement( MVR) using a bioprosthesis was performed. Oral antibiotic therapy was continued for six months after MVR to avoid infection recurrence. One year after MVR, the size of multiple liver metastases increased despite oral anticancer drugs administration. A totally implantable central venous access port( CV port) was placed and intravenous chemotherapy was started for progressive metastatic colorectal cancer. But the CV port was removed due to device infection caused by multiple drug resistant Staphyrococcus lugdunensis one month later, but the patient developed prosthetic valve endocarditits( PVE) due to the same bacterium, that caused valve stenosis. Redo MVR was indicated because of progressive dyspnea and uncontrollable fever. The patient was discharged one month after redo MVR, but suffered carcinomatous peritonitis, and eventually died eight months post-discharge. Chemotherapy needs caution because of potential risk of PVE in patients with prosthetic valves, especially for those with a history of infectious endocarditis.


Assuntos
Neoplasias do Colo , Próteses Valvulares Cardíacas , Valva Mitral , Humanos , Masculino , Idoso , Valva Mitral/cirurgia , Neoplasias do Colo/cirurgia , Neoplasias do Colo/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Evolução Fatal , Reoperação , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/etiologia , Implante de Prótese de Valva Cardíaca , Endocardite Bacteriana/cirurgia
8.
Trials ; 25(1): 324, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38755709

RESUMO

BACKGROUND: The optimal antithrombotic strategy early after aortic valve replacement surgery with a biological valve remains controversial due to lack of high-quality evidence. Either oral anticoagulants or acetylsalicylic acid should be considered for the first 3 months. Hypo-attenuated leaflet thickening on cardiac computed tomography has been associated with latent bioprosthetic valve thrombosis and may be prevented with anticoagulation. We hypothesize that anticoagulation with apixaban is superior to single antiplatelet therapy with acetylsalicylic acid in reducing hypo-attenuated leaflet thickening of bioprosthetic aortic valve prostheses. METHODS: In this prospective, open-label, randomized trial, patients undergoing isolated aortic valve replacement surgery with rapid deployment bioprosthetic valves will be randomized. The treatment group will receive 5 mg of apixaban twice a day for the first 3 months and 100 mg of acetylsalicylic acid thereafter. The control group will be administered 100 mg of acetylsalicylic acid once a day, indefinitely. After the 3-month treatment period, a contrast-enhanced electrocardiogram-gated cardiac computed tomography will be performed to identify hypo-attenuated leaflet thickening of the bioprosthetic valve. The primary objective of the study is to assess the impact of apixaban on the prevention of hypo-attenuated leaflet thickening at 3 months. The secondary and exploratory endpoints will be clinical outcomes and safety profiles of the two strategies. DISCUSSION: Antithrombotic therapy after aortic valve replacement is used to prevent valve thrombosis and systemic thromboembolism. Latent bioprosthetic valve thrombosis is a precursor of clinically significant prosthetic valve dysfunction or thromboembolic events. The hallmark feature of latent bioprosthetic valve thrombosis is hypo-attenuated leaflet thickening on cardiac computed tomography. Subclinical leaflet thrombosis occurs frequently in bioprosthetic aortic valves, more commonly in transcatheter than in surgical valves. There is no evidence on the effect of direct oral anticoagulants on the incidence of hypo-attenuated leaflet thickening after surgical aortic valve replacement with rapid deployment bioprostheses. TRIAL REGISTRATION: ClinicalTrials.gov NCT06184113. Registered on December 28, 2023.


Assuntos
Valva Aórtica , Aspirina , Inibidores do Fator Xa , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Aspirina/administração & dosagem , Aspirina/uso terapêutico , Aspirina/efeitos adversos , Bioprótese , Inibidores do Fator Xa/administração & dosagem , Inibidores do Fator Xa/efeitos adversos , Inibidores do Fator Xa/uso terapêutico , Fibrinolíticos/administração & dosagem , Fibrinolíticos/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/uso terapêutico , Inibidores da Agregação Plaquetária/efeitos adversos , Estudos Prospectivos , Pirazóis/uso terapêutico , Pirazóis/administração & dosagem , Pirazóis/efeitos adversos , Piridonas/uso terapêutico , Piridonas/administração & dosagem , Piridonas/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Trombose/prevenção & controle , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
9.
Clin Cardiol ; 47(5): e24272, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38742736

RESUMO

Paravalvular leak (PVL) is an uncommon complication of prosthetic valve implantation, which can lead to infective endocarditis, heart failure, and hemolytic anemia. Surgical reintervention of PVLs is associated with high mortality rates. Transcatheter PVL closure (TPVLc) has emerged as an alternative to surgical reoperation. This method provides a high success rate with a low rate of complications. This article reviews the pathogenesis, clinical manifestation, diagnosis, and management of PVL and complications following TPVLc. Besides, we presented a case of a patient with severe PVL following mitral valve replacement, who experienced complete heart block (CHB) during TPVLc. The first TPVLc procedure failed in our patient due to possible AV-node insult during catheterization. After 1 week of persistent CHB, a permanent pacemaker was implanted. The defect was successfully passed using the previous attempt. Considering the advantages of TPVLc, procedure failure should be regarded as a concern. TPVLc should be performed by experienced medical teams in carefully selected patients.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral , Falha de Prótese , Humanos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Ecocardiografia Transesofagiana , Masculino , Resultado do Tratamento , Feminino , Idoso , Reoperação
10.
Port J Card Thorac Vasc Surg ; 31(1): 12-16, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38743522

RESUMO

There has been a worldwide rapid adoption of transcatheter aortic valve replacement (TAVR) as an alternative to surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis. Currently, more TAVR explants with SAVRs are performed than TAVR-in TAV. TAVR explantation is a technically hazardous procedure mainly due to significant aortic neo-endothelialization which incorporates the TAVR valve. Surgical techniques for TAVR explantation are not well established and surgeon experience at present is limited. In this manuscript, we describe our technique for surgical explantation of transcatheter aortic bioprosthesis. Familiarity with the procedure and its clinical implications is essential for all cardiac surgeons.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Remoção de Dispositivo , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Remoção de Dispositivo/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação
11.
J Cardiothorac Surg ; 19(1): 164, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561823

RESUMO

BACKGROUND: Mitral regurgitation is a frequent valvular disease, with an increasing prevalence. We analyzed the short-term outcomes of mitral valve repair procedures conducted in our clinic using a new semirigid annuloplasty ring featuring a gradual saddle shape design. METHODS: We retrospectively analyzed mitral valve repair surgeries performed at our Institution between December 2019 and November 2021 with the MEMO 4D semirigid annuloplasty ring. RESULTS: In total, 53 patients were included in the study. Mean patient age was 63.6 ± 11.7 years. Most patients presented with degenerative mitral valve regurgitation (N = 44; 83%). The grade of mitral regurgitation was equal or more than 3 + in 98.1% of the patients (N = 52). The most used ring size was size 34 mm (N = 30, 56.6%). There was no intraoperative or hospital mortality. No cases of stroke, bleeding, endocarditis or other major complications occurred. At discharge, most patients were in NYHA class I. Postoperative echocardiographic results showed no (90.6%) or 1+ (5.7%) mitral valve regurgitation. Only 1 patient (1.9%) presented with mitral valve regurgitation grade 2+. Mean postoperative transvalvular gradient was low (mean = 3.3 ± 1.2 mmHg). No cases of LVOT obstruction or systolic anterior motion occurred. CONCLUSIONS: Our series showed excellent mitral valve competency and very satisfactory early clinical outcomes. The transesophageal echocardiographic follow-up, despite obtained in a limited number of patients, further confirmed the effectiveness of findings of this preliminary experience.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Idoso , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese , Anuloplastia da Valva Mitral/efeitos adversos , Ecocardiografia , Resultado do Tratamento
12.
J Cardiothorac Surg ; 19(1): 219, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627820

RESUMO

OBJECTIVES: Thrombocytopenia following Perceval aortic valve replacement has been described previously with variable outcome. Studies have lacked a robust analysis of platelet fluctuation and factors affecting it. We aimed to statistically describe the trend in thrombocyte variability as compared with conventional aortic valve replacement, and to assess predictors as well as impact on associated outcomes. METHODS: One hundred consecutive patients with first-time Perceval were retrospectively compared to 219 patients after Perimount Magna Ease valve replacement. The primary outcome was the serial thrombocyte count on day 0-6. Generalized estimating equations were used to analyse the data using fixed-effect models: for the effect of the post-operative day on platelet count, and random-effect models estimating both time-variant (platelets) and time in-variant variables (valve type, age, LV function, pre-op platelet level). RESULTS: Perceval patients were older (72 ± 1 vs 68 ± 1 years, p < 0.01) with higher NYHA status (3(2-3) vs 2(1-2), p < 0.001). Mean platelet count in the sutureless group was lowest on day 2 (91.9 ± 31.6 vs 121.7 ± 53.8 × 103 µl-1), and lower on day 4 (97.9 ± 44) and 6 (110.6 ± 61) compared to the conventional group (157.2 ± 60 and 181.7 ± 79) but did not result in a higher number of transfusions, bleeding or longer hospital stay (p > 0.05). Reduced platelet count was a strong predictor of red cell transfusion in the conventional (p = 0.016), but not in the sutureless group (p = 0.457). Age (Coef -1.025, 95%CI-1.649--0.401, p < 0.001) and CPB-time (Coef 0.186, 95%CI-0.371--0.001, p = 0.048) were predictors for lower platelet levels. CONCLUSION: Considering the older patient profile treated with Perceval, postoperative thrombocytopenia does not impact on outcome in terms of transfusions, complications or hospital stay.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Trombocitopenia , Humanos , Valva Aórtica/cirurgia , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Bioprótese/efeitos adversos , Desenho de Prótese , Próteses Valvulares Cardíacas/efeitos adversos , Trombocitopenia/etiologia , Fatores de Risco , Progressão da Doença
13.
J Am Coll Cardiol ; 83(15): 1418-1430, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38599718

RESUMO

During the past 6 decades, there have been numerous changes in prosthetic valve endocarditis (PVE), currently affecting an older population and increasing in incidence in patients with transcatheter-implanted valves. Significant microbiologic (molecular biology) and imaging diagnostic (fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography) advances have been incorporated into the 2023 Duke-International Society for Cardiovascular Infectious Diseases infective endocarditis diagnostic criteria, thus increasing the diagnostic sensitivity for PVE without sacrificing specificity in validation studies. PVE is a life-threatening disease requiring management by multidisciplinary endocarditis teams in cardiac centers to improve outcomes. Novel surgical options are now available, and an increasing set of patients may avoid surgical intervention despite indication. Selected patients may complete parenteral or oral antimicrobial treatment at home. Finally, patients with prosthetic valves implanted surgically or by the transcatheter approach are candidates for antibiotic prophylaxis before invasive dental procedures.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Humanos , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/terapia , Endocardite Bacteriana/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/terapia , Infecções Relacionadas à Prótese/microbiologia , Endocardite/diagnóstico , Endocardite/etiologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
14.
J Cardiothorac Surg ; 19(1): 191, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589959

RESUMO

BACKGROUND: Fungal endocarditis is a rare but serious condition associated with high mortality rates. Various predisposing factors contribute to its occurrence, such as underlying cardiac abnormalities, cardiac surgeries, prosthetic cardiac devices, and central venous catheters. Diagnosing fungal endocarditis, particularly Aspergillus, poses challenges, often complicated by negative blood cultures. CASE PRESENTATION: This report details a case of extensive ascending aorta involvement in Aspergillus endocarditis (AE) in a 24-year-old man with a history of bioprosthesis aortic valve replacement (AVR). Three months post-AVR, he presented with pericardial effusion and aortic rupture, leading to a redo biological valved conduit aortic root replacement (Bentall surgery). Despite the intervention, the tubular graft exhibited extensive Aspergillus involvement, resulting in graft disruption and significant peri-aortic infection. A second redo procedure involving aortic homograft root replacement was performed. Unfortunately, the patient succumbed two days after the surgery. CONCLUSION: A combined approach of medical and surgical therapies is recommended to manage fungal endocarditis. Despite efforts, the mortality rate associated with Aspergillus endocarditis remains unacceptably high, with no significant difference observed between combination therapy and antifungal treatment alone. Further research is essential to explore novel therapeutic strategies and improve outcomes for patients with this challenging condition.


Assuntos
Bioprótese , Endocardite , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Micoses , Humanos , Masculino , Adulto Jovem , Aorta/cirurgia , Aorta Torácica/cirurgia , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Endocardite/diagnóstico , Endocardite/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos
15.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38621698

RESUMO

OBJECTIVES: To assess if warfarin targeted to international normalized ratio (INR) 1.8 (range 1.5-2.0) is safe for all patients with an On-X aortic mechanical valve. METHODS: This prospective, observational registry follows patients receiving warfarin targeted at an INR of 1.8 (range 1.5-2.0) plus daily aspirin (75-100 mg) after On-X aortic valve replacement. The primary end point is a composite of thromboembolism, valve thrombosis and major bleeding. Secondary end points include the individual rates of thromboembolism, valve thrombosis and major bleeding, as well as the composite in subgroups of home or clinic-monitored INR and risk categorization for thromboembolism. The control was the patient group randomized to standard-dose warfarin (INR 2.0-3.0) plus daily aspirin 81 mg from the PROACT trial. RESULTS: A total of 510 patients were enroled at 23 centres in the UK, USA and Canada. Currently, the median follow-up duration is 3.4 years, and median achieved INR is 1.9. The primary composite end point rate in the low INR patients is 2.31% vs 5.39% (95% confidence interval 4.12-6.93%) per patient-year in the PROACT control group, constituting a 57% reduction. Results are consistent in subgroups of home or clinic-monitored, and high-risk patients, with reductions of 56%, 57% and 57%, respectively. Major and total bleeding are decreased by 85% and 73%, respectively, with similar rates of thromboembolic events. No valve thrombosis occurred. CONCLUSIONS: Interim results suggest that warfarin targeted at an INR of 1.8 (range 1.5-2.0) plus aspirin is safe and effective in patients with an On-X aortic mechanical valve with or without home INR monitoring.


Assuntos
Anticoagulantes , Valva Aórtica , Aspirina , Implante de Prótese de Valva Cardíaca , Coeficiente Internacional Normatizado , Tromboembolia , Varfarina , Humanos , Varfarina/administração & dosagem , Varfarina/efeitos adversos , Aspirina/administração & dosagem , Aspirina/efeitos adversos , Masculino , Feminino , Valva Aórtica/cirurgia , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Estudos Prospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Tromboembolia/prevenção & controle , Tromboembolia/etiologia , Pessoa de Meia-Idade , Próteses Valvulares Cardíacas/efeitos adversos , Trombose/prevenção & controle , Trombose/etiologia , Hemorragia/induzido quimicamente
16.
J Cardiothorac Surg ; 19(1): 114, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38468271

RESUMO

Prosthetic valve thrombosis (PVT) in aortic valve and its complication coronary embolism is a very rare condition. Diagnosis and treatment process is challenging. We present a young patient with acute myocardial infarction who underwent mechanical aortic valve replacement (AVR) operation one month earlier. Percutaneous coronary intervention was performed and it was succesful. Transeasophageal ecocardiography (TEE) was performed. Thrombus was seen on the mechanical aortic valve and thrombolytic therapy was initiated. Control TEE was performed and there was no signs of thrombi. The patient was discharged healthfully with anticoagulant and antiaggregan.


Assuntos
Doença da Artéria Coronariana , Embolia , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Infarto do Miocárdio , Humanos , Valva Aórtica/cirurgia , Infarto do Miocárdio/cirurgia , Infarto do Miocárdio/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Embolia/cirurgia , Embolia/complicações , Doenças das Valvas Cardíacas/cirurgia , Doença da Artéria Coronariana/complicações
17.
Kyobu Geka ; 77(3): 206-209, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465492

RESUMO

We report a case of bioprosthetic valve dysfunction and acute aortic valve regurgitation. The case was a 75-year-old female who had sudden onset chest pain. ST-segment depression in several leads on electrocardiogram( ECG) suggested acute coronary syndrome. Coronary angiography showed no significant stenosis in coronary arteries. Transesophageal echocardiography revealed severe aortic regurgitation, suggesting that angina was caused by myocardial ischemia associated with acute aortic regurgitation. She was diagnosed as having bioprosthetic valve dysfunction, and underwent redo aortic valve replacement. One leaflet of the bioprosthetic valve was torn along the stent post and caused bioprosthetic valve dysfunction. Failed bioprosthetic valve was removed and replaced by a mechanical valve.


Assuntos
Insuficiência da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Feminino , Humanos , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Tórax , Próteses Valvulares Cardíacas/efeitos adversos , Dor no Peito/etiologia , Bioprótese/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos
18.
Kyobu Geka ; 77(3): 191-195, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465491

RESUMO

We experienced a case of surgical aortic valve re-replacement due to structural valve deterioration caused by pannus formation 4 years after transcatheter aortic valve replacement( TAVR). The patient underwent surgery because the mean transvalvular pressure gradient increased to 48 mmHg on echocardiography. Contrast-enhanced computed tomography (CT) was useful for predicting the site of adhesion to surrounding tissue preoperatively and exploring the presence of the pannus. Intraoperative findings showed the TAVR valve was covered with neointima except around the origins of the left and right coronary arteries and was firmly adhered to the surrounding tissues. As residual pannus was present in the subvalvular tissues, it was carefully removed. The explanted TAVR valve functioned well with good opening and closure. The postoperative course was uneventful. Pannus formation can result from mechanical stress. TAVR valves put significantly greater stress on the left ventricular outflow tract than surgical valves and may be more likely to cause pannus formation.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Obstrução da Via de Saída Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Pannus , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia
19.
Kyobu Geka ; 77(2): 106-109, 2024 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-38459859

RESUMO

INTRODUCTION: Pulsed lavage irrigation (PLI) is a procedure used to wash contaminated soft tissues and prevent infection in orthopedic surgery. We applicated PLI for surgical treatment of infective endocarditis( IE). SUBJECTS AND METHODS: From January 2017 to June 2021, 6 cases underwent surgical treatment IE using PLI. We investigated an efficacy of PLI. RESULTS: Infected valves were mitral valve in 4 cases, aortic valve in 1 case, and aortic prosthetic valve in 1 case. The performed procedures were mitral valve plasty in 4 cases, aortic valve replacement in 1 case, and 1 removal of vegetation on the aortic prosthetic valve. No recurrence of IE or no deterioration of the native valve or the prosthetic valve was observed in follow-up periods. CONCLUSION: PLI was useful for surgical treatment of IE because of no recurrence of IE or no deterioration of native mitral valves or the aortic prosthetic valve.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Humanos , Irrigação Terapêutica/efeitos adversos , Endocardite Bacteriana/cirurgia , Endocardite Bacteriana/complicações , Endocardite/cirurgia , Valva Mitral/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos
20.
J Infect Public Health ; 17(4): 712-718, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38484416

RESUMO

BACKGROUND: Infective endocarditis continues to be a significant concern and may be undergoing an epidemiological transition. METHODS: Were studied 1804 consecutive episodes of infective endocarditis between 1978 and 2022. The mean age was 48 ( ± 19), and 1162 (64%) patients were male. Temporal trends in demographic data, comorbidities, predisposing conditions, microorganisms, complications and in-hospital death have been studied over the decades (1978-1988, 1989-1999, 2000-2010 and 2011-2022). The outcomes and clinical characteristics were modeled using nonlinear cubic spline functions. FINDINGS: Valve surgery was performed in 50% of the patients and overall in-hospital mortality was 30%. From the first to the fourth decade studied, the average age of patients increased from 29 to 57 years (p < 0.001), with significant declines in the occurrence of rheumatic valvular heart disease (15% to 6%; p < 0.001) and streptococcal infections (46% to 33%; p < 0.001). Healthcare-associated infections have increased (9% to 21%; p < 0.001), as have prosthetic valve endocarditis (26% to 53%; p < 0.001), coagulase-negative staphylococcal infections (4% to 11%; p < 0.001), and related-complications (heart failure, embolic events, and perivalvular abscess; p < 0.001). These changes were associated with a decline in adjusted in-hospital mortality from 34% to 25% (p = 0.019). INTERPRETATION: In the 44 years studied, there was an increase in the mean age of patients, healthcare-related, prosthetic valve, coagulase-negative staphylococci/MRSA infections, and related complications. Notably, these epidemiological changes were associated with a decline in the adjusted in-hospital mortality.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Infecções Estafilocócicas , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Endocardite Bacteriana/cirurgia , Mortalidade Hospitalar , Coagulase , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Endocardite/epidemiologia , Staphylococcus , Infecções Estafilocócicas/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA