1.
Clin Oral Investig ; 28(4): 214, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38485869

RESUMO

OBJECTIVES: This study aims to analyze the working time consumed during caries excavation and pain perception while using a novel Bioactive caries-detecting dye solution (BCD), an Air Polisher Prophy and a combination. MATERIALS AND METHODS: Four groups (in each group, n = 20 permanent teeth) were selected from 60 people between 17 and 40 years of age. The study included teeth with occlusal dentinal caries in the molars with cavity entrance sizes of less than 2 mm (clinically and radiographically). Randomization software was used to assign patients to various groups. Group A: Conventional Rotary Drilling, Group B: BCD + Mechanical Excavation (Spoon Excavator), Group C: Air Polisher Prophy, and Group D: BCD + Air Polisher Prophy 0.5 mL BCD was applied with a micro brush to the carious tooth surface for 40 s in groups B and D. After that, radiographs were performed to see if the radiopaque extension was visible. For mechanical caries extraction, a spoon excavator was used for group B, and an air polisher prophy was employed for group D. For mechanical caries extraction, a spoon excavator was utilized for group B. An air polisher prophy was employed for group D. Multiple applications of the BCD were used in the event of residual caries. Working time and pain experienced during caries excavation were registered using the Verbal Pain Scale (VPS) (score 0-4), and caries removal was clinically graded using the modified Scale (score 0-5). RESULTS: The time taken was Group A, Group D, Group B, and Group C, according to statistical analysis using ANOVA and the Post Hoc Test (275.02, 403.8, 461.98, 615.41 s, respectively). Group A had the highest mean VPS (1.85), whereas Group B had the most minor pain (0.6), followed by Group D (1.2) and Group C (0.6). (1.45). Group C (2.35), followed by groups D (1.75), B (1.30), and A (1.30), had ineffective caries eradication (0.90). (p < 0.05). CONCLUSIONS: compared to group C, groups B and D took less time and had less/no pain while excavating caries. Compared to traditional mechanized caries removal methods, the chemo-chemical BCD can diagnose and aid in successful caries removal with minimal pain. CLINICAL RELEVANCE: The outcomes of the present study demonstrated that the chemo-chemical bioactive caries detecting dye solution has the potential to identify and help in effective caries removal before mechanized caries removal methods.


Assuntos
Suscetibilidade à Cárie Dentária , Cárie Dentária , Humanos , Cárie Dentária/terapia , Preparo da Cavidade Dentária/métodos , Dentina , Dor , Adolescente , Adulto Jovem , Adulto
2.
Technol Health Care ; 31(6): 2381-2387, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37302052

RESUMO

BACKGROUND: The minimally invasive endodontics could retain more peri-cervical dentin (PCD) and other important dental structures, thus realizing the minimal loss of teeth structures and preserving the strength and function of the endodontically treated tooth (ETT). The search for abnormal root canals or calcified root canals could be quite time-consuming and increase the risk of perforation. OBJECTIVE: This study introduced a novel multifunctional 3D printing guided splint inspired by the dice, which can achieve the minimally invasive access cavity preparation and canal orifice identification. METHOD: Data were collected from an outpatient with dens invaginatus. Cone-beam Computed Tomography (CBCT) revealed a type III invagination. The CBCT data of the patient were imported into a computer-aided design (CAD) software (Exocad 3.0; Exocad GmbH) for the 3D reconstruction of jaw bones and teeth. The dice-inspired 3D printing guided splint consists of the sleeve and guided splint. The sleeve with minimal invasive opening channel and orifice locating channel were designed with a reverse-engineering software (Geomagic Wrap 2021). The reconstructed models in the Standard Template Library (STL) format were imported into a CAD software. The design of the template was aided by the dental CAD software in Splint Design Mode. The sleeve and splint were exported into the STL files separately. A 3D printer (ProJet® 3600 3D Systems) was used to separately generate the sleeve and guided splint, and was made by stereolithography and processed in a medical resin (VisiJet M3 StonePlast). RESULTS: The novel multifunctional 3D printing guided splint could be set in position. The opening side in the sleeve was selected and the sleeve was inserted in place. The minimal invasive opening was made in the crown of the tooth to access the pulp. The sleeve was draw out and turned to the orifice location side, and then inserted in place. The target orifice was located rapidly. CONCLUSION: This novel dice-inspired multifunctional 3D printing guided splint allow dental practitioners to gain accurate, conservative, and safe cavity access from teeth with anatomical malformations. Complex operations might be carried out with less reliance on the operator's experience than with conventional access preparations. This novel dice-inspired multifunctional 3D printing guided splint would have a broad application in the dental field.


Assuntos
Preparo da Cavidade Dentária , Preparo de Canal Radicular , Contenções , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Odontólogos , Impressão Tridimensional , Papel Profissional , Preparo de Canal Radicular/métodos , Procedimentos Cirúrgicos Minimamente Invasivos , Preparo da Cavidade Dentária/métodos
3.
Rev. Fac. Odontol. (B.Aires) ; 37(85): 7-14, 2022. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1397370

RESUMO

La amelogénesis imperfecta (AI) es un grupo de tras-tornos hereditarios, clínica y etiológicamente hete-rogéneos, derivados de mutaciones genéticas, que se caracterizan por anomalías cualitativas y cuanti-tativas del desarrollo del esmalte, pudiendo afectar la dentición primaria y/o permanente. El tratamiento del paciente con AI es complejo y multidiscliplinario; supone un desafío para el odontólogo, ya que por lo general están involucradas todas las piezas dentarias y afecta no solo la salud buco dental sino el aspecto emocional y psicológico de los pacientes. Con el obje-tivo de describir el tratamiento integral y rehabilita-dor realizado en una paciente con diagnóstico de AI tipo III, se reporta el caso de un adolescente de sexo femenino de 13 años, que concurrió en demanda de atención a la Cátedra de Odontología Integral Niños de la Facultad de Odontología de la Universidad de Buenos Aires (FOUBA), cuyo motivo de consulta fue la apariencia estética y la hipersensibilidad de sus pie-zas dentarias. Durante el examen clínico intraoral, se observó que todas las piezas dentarias presentaban un esmalte rugoso, blando, con irregularidades y una coloración amarronada, compatible con diagnóstico de Amelogénesis Imperfecta tipo III hipomineralizada. Conclusión: El tratamiento rehabilitador de la AI en los pacientes en crecimiento y desarrollo estará diri-gido a intervenir de manera integral y temprana para resolver la apariencia estética y funcional, evitar las repercusiones sociales y emocionales, y acompañar a los pacientes y sus familias (AU)


Amelogenesis imperfecta (AI) is a group of clinically and etiologically heterogeneous hereditary disorders, derived from genetic mutations, characterized by qualitative and quantitative anomalies of enamel development, which can affect primary and/or permanent dentition. The treatment of patients with AI is complex and multidisciplinary, it is a challenge for the dentist, since in general all the teeth are involved and it affects not only oral health but also the emotional and psychological aspect of the patients. Objective: To describe the comprehensive and rehabilitative treatment carried out in an adolescent patient with a diagnosis of type III AI. Case report: The case of a 13-year-old female patient, who required dental attention at the Department of Dentistry for Children of the School of Dentistry of the University of Buenos Aires, whose reason for consultation was esthetic appearance and hypersensitivity of her teeth. In the intraoral clinical examination, it was observed that all the teeth had rough, soft enamel, with irregularities and a brownish color, compatible with the diagnosis of type III hypomineralized Amelogenesis Imperfecta. Conclusion: Rehabilitative treatment of AI in growing and developing patients will be aimed at early and comprehensive intervention to resolve esthetic and functional appearance, avoid social and emotional repercussions and accompany patients and their families (AU)


Assuntos
Humanos , Feminino , Adolescente , Assistência Odontológica para Crianças , Coroas , Amelogênese Imperfeita/terapia , Equipe de Assistência ao Paciente , Faculdades de Odontologia , Preparo da Cavidade Dentária/métodos , Esmalte Dentário/patologia , Hipoplasia do Esmalte Dentário/etiologia , Restauração Dentária Permanente/métodos , Estética Dentária , Amelogênese Imperfeita/classificação
4.
RFO UPF ; 26(1): 106-112, 20210327. ilus
Artigo em Português | LILACS, BBO | ID: biblio-1435377

RESUMO

Objetivo: este artigo se propõe a discutir o tratamento de lesões profundas de cárie em molares permanentes, através da técnica de remoção seletiva de tecido cariado e restauração de resina composta, em dois casos clínicos, utilizando apenas sistema adesivo (caso 1) ou proteção pulpar indireta com cimento de hidróxido de cálcio (caso 2). Relato de casos: os indivíduos foram diagnosticados com dentes apresentando lesões profundas de cárie, isto é, com mais de 50% em profundidade da dentina, confirmada pelo exame radiográfico interproximal. O conjunto de resultados de testes de sensibilidade pulpar positivo ao frio e teste de percussão horizontal e vertical negativos, juntamente com a ausência de dor espontânea e normalidade do periápice (radiografia periapical), completaram os requisitos exigidos para execução da técnica de remoção seletiva de dentina cariada amolecida. Os dentes receberam restaurações adesivas na mesma sessão, sobre a dentina cariada amolecida da parede pulpar que havia recebido forramento de cimento de hidróxido de cálcio ou não, dependentes de uma randomização. Ambos os casos apresentados mostraram sucesso clínico em acompanhamento de 18 meses, tanto na manutenção da vitalidade pulpar quanto na sobrevivência da restauração. Considerações finais: com base nos casos apresentados, sabendo das limitações deste modelo de estudo, e em concordância com a literatura, a remoção seletiva de tecido cariado pode ser executada com sucesso no tratamento de lesões profundas de cárie, respeitando-se todos os passos da técnica, e parece não haver necessidade de uso de proteção pulpar indireta.(AU)


Objective: this article aims to discuss the treatment of deep caries lesions in permanent molars through the selective caries tissue removal technique and composite resin restoration of two clinical cases, using only an adhesive system (case 1) or an indirect pulp protection of calcium hydroxide cement (case 2). Cases report: the participants were diagnosed with deep caries lesions, that is, more than 50% in depth of the dentin involved, which was confirmed by the interproximal radiography. In both cases, it was obtained positive response to cold test, negative response to horizontal and vertical percussion tests, absence of spontaneous pain and no periapical lesion (periapical radiography), which completed the requirements for performing the selective caries removal of soft dentin. These teeth received adhesive restorations in the same session, under the softened carious dentin of the pulp wall that had received calcium hydroxide cement or not, depending on randomization. Both cases had clinical success in the 18-month follow- -up, showing pulp vitality and restoration survival. Final considerations: based on the clinical cases reported, considering de limitations of this study model, and in agreement with the literature, the selective removal of carious tissue can be successfully performed in the treatment of deep carious lesions, respecting all the steps of the technique and indirect pulp protection seems to be unnecessary.(AU)


Assuntos
Humanos , Feminino , Adolescente , Adulto , Cárie Dentária/terapia , Preparo da Cavidade Dentária/métodos , Polpa Dentária , Restauração Dentária Permanente/métodos , Hidróxido de Cálcio/uso terapêutico , Resultado do Tratamento , Resinas Compostas/uso terapêutico
5.
Photobiomodul Photomed Laser Surg ; 38(5): 301-307, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32427550

RESUMO

Objective: This study was conducted to (1) evaluate a new method for accurately and automatically preparing dental implant cavities; (2) investigate the quantitative relationships between the number of focal-plane additive pulse layers (n) in two-dimensional ablation, the Z-axis feed rate, and the ablation depth (d) during cortical-bone ablation using a numerically controlled three-axis picosecond laser; and (3) establish appropriate methods for precise ablation control. Materials and methods: Two-dimensional ablation was performed on swine-rib blocks in the focal plane on a preset circular path using a picosecond laser device and an in-house-developed three-axis numerically controlled micro-laser galvanometer scanner. The maximum two-dimensional d and the quantitative relationship between n and d within the maximum d were consequently obtained. The measured and theoretical values of the ablated cavities were then compared to obtain n and d values corresponding to the minimum difference, and to evaluate the error in d, resulting in a higher-accuracy d value (i.e., single-step ablation depth) being obtained. Results: The diameter and deep errors between the measured and design data for 24 cavities were 2.76 ± 1.51 and 10.23 ± 4.82 µm, respectively. Thus, high-quality cortical-bone cavities preparation was achieved using a picosecond laser with the parameters employed in this study. Conclusions: Precise control of cortical-bone ablation using a picosecond laser can be attained by optimizing the single-step ablation parameters.


Assuntos
Osso Cortical/efeitos da radiação , Preparo da Cavidade Dentária/métodos , Terapia com Luz de Baixa Intensidade , Animais , Modelos Animais , Suínos , Técnicas de Cultura de Tecidos
6.
J. appl. oral sci ; 28: e20190042, 2020. graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1056592

RESUMO

Abstract Gap formation of composite resin restorations is a serious shortcoming in clinical practice. Polymerization shrinkage stress exceeds the tooth-restoration bond strength, and it causes bacterial infiltration within gaps between cavity walls and the restorative material. Thus, an intermediate liner application with a low elastic modulus has been advised to minimize polymerization shrinkage as well as gap formation. Objective: The purpose of this in vitro study was to assess gap formation volume in premolars restored with different bulk-fill composites, with and without a resin-modified glass-ionomer cement (RMGIC) liner, using x-ray micro-computed tomography (micro-CT). Methodology: Sixty extracted human maxillary premolars were divided into six groups according to bucco-palatal dimensions (n=10). Standardized Class II mesio-occluso-distal cavities were prepared. G-Premio Bond (GC Corp., Japan) was applied in the selective-etch mode. Teeth were restored with high-viscosity (Filtek Bulk Fill, 3M ESPE, USA)-FB, sonic-activated (SonicFill 2, Kerr, USA)-SF and low viscosity (Estelite Bulk Fill Flow, Tokuyama, Japan)-EB bulk-fill composites, with and without a liner (Ionoseal, Voco GmbH, Germany)-L. The specimens were subjected to 10,000 thermocycles (5-55°C) and 50,000 simulated chewing cycles (100 N). Gap formation based on the volume of black spaces at the tooth-restoration interface was quantified in mm3 using micro-computed tomography (SkyScan, Belgium), and analyses were performed. Data were analyzed using repeated-measures ANOVA and the Bonferroni correction test (p < 0.05). Results: The gap volume of all tested bulk-fill composites demonstrated that Group SF (1.581±0.773) had significantly higher values than Group EB (0.717±0.679). Regarding the use of a liner, a significant reduction in gap formation volume was observed only in Group SFL (0.927±0.630) compared with Group SF (1.581±0.773). Conclusion: It can be concluded that different types of bulk-fill composite resins affected gap formation volume. Low-viscosity bulk-fill composites exhibited better adaptation to cavity walls and less gap formation than did sonic-activated bulk-fill composites. The use of an RMGIC liner produced a significant reduction in gap formation volume for sonic-activated bulk-fill composites.


Assuntos
Humanos , Resinas Compostas/química , Imageamento Tridimensional/métodos , Preparo da Cavidade Dentária/métodos , Materiais Dentários/química , Restauração Dentária Permanente/métodos , Polimerização , Técnicas In Vitro , Teste de Materiais , Cimentos de Resina , Análise do Estresse Dentário , Microtomografia por Raio-X
7.
J. appl. oral sci ; 27: e20180631, 2019. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1012520

RESUMO

Abstract Extensive restorations in posterior teeth always bring doubts to the clinicians regarding the best protocol, mainly when structures of reinforcement were lost. Objective This study aimed to evaluate the effect of beveling on the fracture resistance and pattern of class II (MOD) restored teeth. Methodology Ninety human premolars were randomly assigned into 9 groups: CTR (control/sound); NC (cavity preparation, non-restored); RU (restored, unbeveled); RTB (restored, entire angle beveling); RPB (restored, partial/occlusal beveling); EC (endodontic access/EA, non-restored); EU (EA, unbeveled); ETB (EA, entire angle beveling); EPB (EA, partial/occlusal beveling). Teeth were restored with Esthet X resin composite and stored in distilled water for 24 h before the inclusion in PVC cylinders. The axial loading tests were performed with 500 kgF at 0.5 mm/min crosshead speed until fracture of the specimens. Fracture resistance and pattern were accessed and data were analyzed using one-way ANOVA and Tukey's HSD test (α=0.05). Results Mean (±SD) failure loads ranged from 136.56 (11.62) to 174.04 (43.5) kgF in the groups tested without endodontic access. For endodontically accessed teeth, fracture resistance ranged from 95.54 (13.05) to 126.51 (19.88) kgF. Beveling of the cavosurface angle promoted the highest fracture resistance values (p<0.05) and prevented catastrophic fractures. Conclusions Cavosurface angle beveling is capable of improving fracture resistance and pattern for both endodonticaly accessed and non-accessed teeth.


Assuntos
Humanos , Dente Pré-Molar , Preparo da Cavidade Dentária/métodos , Restauração Dentária Permanente/métodos , Valores de Referência , Fraturas dos Dentes , Distribuição Aleatória , Reprodutibilidade dos Testes , Fatores de Risco , Análise de Variância , Resultado do Tratamento , Resinas Compostas/uso terapêutico , Dente não Vital
8.
Mater Sci Eng C Mater Biol Appl ; 90: 433-438, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-29853109

RESUMO

PURPOSE: The purpose of the present work was to achieve fast and more precise ablation in dentin and enamel by using a commercial femtosecond laser system with high repetition rate, whilst avoiding any collateral irreversible damages in the hard tissue and pulp area. METHODS: We used fluence of the incident laser pulses which was marginally higher than the ablation threshold for dentin and enamel. The study was based on the hypothesis that femtosecond laser operating with a repetition rate in the range of 100-500 kHz can controllably ablate dental tissue obtaining sufficiently high removal rate whilst avoiding any collateral irreversible damages in the hard tissue and pulp area. RESULTS: The ablation yielded the formation of 1 mm3 craters with well-defined precise vertical cavity sides and edges. Advantageous high porosity and numerous interconnected pores were introduced in the ablated zones. Thermal load and hence collateral thermo-mechanical damages were avoided and the crystalline structure of the tooth constituent hydroxyapatite was preserved. CONCLUSION: The ultrafast femtosecond laser used in our work hold the promise of a significant drilling ability without collateral thermomechanical effects. It achieves high processing efficiency, overcomes disadvantages of other laser systems reported and can be used to develop an instrument for cavity preparation based on fast and precise ablation. Our further aim is to exceed the speed of traditional drilling instruments and thus to reduce the treatment time which in turn will bring comfort to the patient.


Assuntos
Esmalte Dentário/química , Dentina/química , Preparo da Cavidade Dentária/métodos , Humanos , Terapia a Laser
9.
Photomed Laser Surg ; 36(11): 589-594, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29813001

RESUMO

OBJECTIVE: In this in vitro study, cross-polarization optical coherence tomography (CP-OCT) was used to evaluate microleakage in dental composite restorations bonded to enamel with two types of one-step self-etching (SE) adhesives. BACKGROUND DATA: One-step SE adhesives were proposed to simplify bonding of composite restorations. However, bonding of these simplified adhesive to dental enamel is still questionable. OCT is a promising diagnostic tool that allows micron-scale imaging of biological tissues and structures. METHODS: Class-V cavities (4-mm diameter × 1-mm depth) were prepared on the labial surfaces of extracted human anterior teeth with margins and floor located in enamel. The cavities were then divided into two groups (n = 5) and restored with either Tetric N-Bond Universal (Ivoclar Vivadent, Liechtenstein) or Palfique Bond (Tokuyama Dental Corporation, Japan), followed by Estelite Flow Quick flowable composite (Tokuyama Dental Corporation). After storage in 100% humidity for 24 h, specimens were immersed in ammoniacal silver nitrate solution for another 24 h. Later, they were rinsed and immersed in photo-developing solution under fluorescent light for 8 h. CP-OCT at 1310 nm center wavelength was used to scan seven two-dimensional cross-sectional images from each specimen. Each cross-sectional image was analyzed using ImageJ software to quantify interfacial microleakage at the cavity floor. RESULTS: Student's t-test showed significant difference between the tested adhesives (p < 0.05). Palfique Bond adhesive presented inferior interfacial adaptation as it obtained higher values of floor microleakage compared to Tetric N-Bond Universal adhesive group. CONCLUSIONS: CP-OCT enabled nondestructive quantitative assessment of microleakage in enamel dental restorations.


Assuntos
Resinas Compostas/química , Colagem Dentária , Preparo da Cavidade Dentária/métodos , Cimentos Dentários/química , Esmalte Dentário/efeitos dos fármacos , Corrosão Dentária/métodos , Infiltração Dentária , Tomografia de Coerência Óptica , Restauração Dentária Permanente/métodos , Humanos , Técnicas In Vitro
10.
Braz. dent. j ; 29(3): 268-274, May-June 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-951545

RESUMO

Abstract The aim was to evaluate the influence of different dentin preparation mode in the smear layer characteristics (SL), hybrid layer (HL), and microtensile bond strength (µTBS) to dentin with two resin cements. The occlusal dentin of 120 third molars was exposed. The teeth were divided into 4 groups (n=30) according to the dentin preparation mode: 1- fine grain diamond bur; 2- coarse grain diamond bur; 3- multi laminate carbide steel bur; and, 4- ultrasonic CV Dentus diamond bur. Each treated dentin group was divided into 2 sub-groups (n=15) according to the resin cement: (1) RelyX U200 and (2) RelyX ARC. Resin composite blocks were cemented on dentin. After storage at 37o C for 24 h, beams with a cross section area of 1.0 mm2 were obtained, and tested in a universal testing machine at a crosshead speed of 0.5 mm/min. Two additional teeth for each sub-group were prepared to analyze the SL and HL on a scanning electron microscopy. According to Kruskal-Wallis test and Dunn tests, there was no significant difference in µTBS among the rotary instruments within each resin cement group. RelyX ARC obtained higher µTBS values compared to RelyX U200 (p<0.05). RelyX ARC formed evident HL, which was not observed for RelyX U200. The dentin mode preparation did not influence the µTBS of the resin cements. The SL was different for all instruments. The cementing agent is more determinant in the hybrid layer formation and bond strength to dentin than the instruments applied on dentin.


Resumo O objetivo deste estudo foi avaliar a influência de diferentes modos de preparação da dentina nas características da smear layer (SL), da camada híbrida (CH) e na resistência de união à microtração (RUµT) à dentina com dois cimentos resinosos. A dentina oclusal de 120 terceiros molares humanos foi exposta. Os dentes foram divididos em 4 grupos (n=30) de acordo com o modo de preparação da dentina: 1 - ponta diamantada de granulação fina; 2 - ponta diamantada de granulação grossa; 3 - ponta de carboneto de aço multilaminada; 4 - ponta diamantada ultrassônica. Cada grupo foi subdividido em dois subgrupos (n=15) de acordo com o cimento resinoso: (1) RelyX U200 e (2) RelyX ARC. Blocos de resina composta foram cimentados na dentina. Após armazenamento a 37 °C por 24 h, as amostras foram cortadas para obter palitos com área de 1,0 mm2, os quais foram testados em máquina de ensaio universal com velocidade de 0,5 mm/min. Dois dentes adicionais por subgrupo foram preparados para analisar as características da SL e da CH em microscópio eletrônico de varredura. De acordo com o teste de Kruskal-Wallis e o teste de Dunn, não houve diferença significativa na RUµT entre os instrumentos rotatórios para cada cimento resinoso. RelyX ARC obteve maiores valores de RUµT em comparação ao RelyX U200 (p<0,05). RelyX ARC formou uma CH evidente, o que não foi observado para o RelyX U200. O modo de preparação da dentina não influenciou na RUµT dos cimentos resinosos. A SL foi diferente para todos os instrumentos. O agente de cimentação foi mais determinante na formação da camada híbrida e na resistência de união do que os instrumentos utilizados para preparar a dentina.


Assuntos
Humanos , Resistência à Tração , Colagem Dentária , Adesivos Dentinários/química , Cimentos de Resina/química , Preparo da Cavidade Dentária/métodos , Dentina/química , Polietilenoglicóis , Ácidos Polimetacrílicos , Microscopia Eletrônica de Varredura , Camada de Esfregaço , Bis-Fenol A-Glicidil Metacrilato , Análise do Estresse Dentário , Dente Serotino/química
11.
Oper Dent ; 43(3): E110-E118, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29513643

RESUMO

This work presents the multilayered caries model with a visuo-tactile virtual reality simulator and a randomized controlled trial protocol to determine the effectiveness of the simulator in training for minimally invasive caries removal. A three-dimensional, multilayered caries model was reconstructed from 10 micro-computed tomography (CT) images of deeply carious extracted human teeth before and after caries removal. The full grey scale 0-255 yielded a median grey scale value of 0-9, 10-18, 19-25, 26-52, and 53-80 regarding dental pulp, infected carious dentin, affected carious dentin, normal dentin, and normal enamel, respectively. The simulator was connected to two haptic devices for a handpiece and mouth mirror. The visuo-tactile feedback during the operation varied depending on the grey scale. Sixth-year dental students underwent a pretraining assessment of caries removal on extracted teeth. The students were then randomly assigned to train on either the simulator (n=16) or conventional extracted teeth (n=16) for 3 days, after which the assessment was repeated. The posttraining performance of caries removal improved compared with pretraining in both groups (Wilcoxon, p<0.05). The equivalence test for proportional differences (two 1-sided t-tests) with a 0.2 margin confirmed that the participants in both groups had identical posttraining performance scores (95% CI=0.92, 1; p=0.00). In conclusion, training on the micro-CT multilayered caries model with the visuo-tactile virtual reality simulator and conventional extracted tooth had equivalent effects on improving performance of minimally invasive caries removal.


Assuntos
Cárie Dentária/cirurgia , Educação em Odontologia/métodos , Modelos Dentários , Interface Usuário-Computador , Cárie Dentária/diagnóstico por imagem , Preparo da Cavidade Dentária/métodos , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/educação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Estudantes de Odontologia , Microtomografia por Raio-X
12.
Int Endod J ; 51(2): 247-255, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28665514

RESUMO

AIM: To present a novel miniaturized and minimally invasive treatment approach for root canal localization in mandibular incisors with pulp canal calcification and apical periodontitis. SUMMARY: A 51-year-old male patient presented with pain from his mandibular incisors. The patient had a history of severe dental trauma over 30 years ago. Both mandibular central incisors (teeth 31, 41) were tender to percussion and had a yellowish discoloration. They did not respond to thermal and electrical sensitivity tests. Two periapical radiographs from different projections revealed severe pulp canal calcifications and signs of periapical periodontitis. To facilitate the 'Microguided Endodontics' technique, a CBCT and an intra-oral surface scan were aligned using special software. This allowed the virtual planning of optimal access cavities up to the apical third of the root. In this technique, a 3D-printed template guides a customized drill to the orifice of the root canal. After negotiation of the root canals, conventional root canal treatment was performed. This case report demonstrates that minimally invasive and apically extended access cavities are feasible in mandibular incisors with this technique. KEY LEARNING POINTS: The 'Microguided Endodontics' technique is a safe and minimally invasive method for root canal location and prevention of technical failures in anterior teeth with pulp canal calcification.


Assuntos
Preparo da Cavidade Dentária/métodos , Calcificações da Polpa Dentária/terapia , Cavidade Pulpar/anatomia & histologia , Incisivo , Periodontite Periapical/terapia , Humanos , Masculino , Mandíbula , Pessoa de Meia-Idade , Terapia Assistida por Computador
13.
Braz. j. med. biol. res ; 51(3): e6872, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889038

RESUMO

The primary objective of this in vitro study was to evaluate the efficiency of removal of cariogenic bacteria and carious dentin by ablation using two lasers: fluorescence-feedback controlled (FFC) Er:YAG laser and different pulses of Er:YAG laser based on variable square pulse technology (VSPt). The secondary objective was to measure the temperature during laser ablation of carious tissue. Seventy-two extracted human molars were used in this study. Sixty teeth with carious dentin were randomly divided into four experimental groups according to the treatment for caries removal: group 1: 400 µs (FFC group); group 2: super short pulse (SSP group, 50 µs pulse); group 3: medium short pulse (MSP group, 100 µs pulse); group 4: short pulse (SP group, 300 µs pulse) and one positive control group with no treatment. Twelve teeth without carious lesion were used as a negative control group. After caries removal, swabs were taken with cotton pellets and real-time PCR analysis was performed. During caries ablation, a thermal infrared camera was used to measure the temperature changes. In all experimental groups, specimens were free of bacterial contamination after the treatment. In the SSP, MSP and SP groups, temperatures measured during caries ablation were significantly higher compared to temperatures in the FFC group (P<0.001). In this in vitro study, laser treatment for removal of carious dentin and cariogenic bacteria was an efficient treatment modality without causing excessive temperatures that might adversely affect pulp vitality.


Assuntos
Humanos , Bactérias/isolamento & purificação , Cárie Dentária/terapia , Preparo da Cavidade Dentária/métodos , Dentina/microbiologia , Lasers de Estado Sólido/uso terapêutico , Cárie Dentária/diagnóstico , Polpa Dentária/fisiologia , Bactérias Gram-Negativas/isolamento & purificação , Bactérias Gram-Positivas/isolamento & purificação , Raios Infravermelhos , Reação em Cadeia da Polimerase em Tempo Real , Temperatura , Termografia
14.
J. appl. oral sci ; 26: e20180004, 2018. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-954510

RESUMO

Abstract Objective This study aimed to evaluate the effect of the cavity preparation and ceramic type on the stress distribution, tooth strain, fracture resistance and fracture mode of human molar teeth restored with onlays. Material and Methods Forty-eight molars were divided into four groups (n=12) with assorted combinations of two study factors: BL- conventional onlay preparation with boxes made from leucite ceramic (IPS-Empress CAD, Ivoclar Vivadent); NBL- conservative onlay preparation without boxes made from leucite ceramic; BD- conventional onlay preparation with boxes made from lithium disilicate glass ceramic (IPS e.max CAD, Ivoclar Vivadent); NBL- conservative onlay preparation with boxes made from lithium disilicate glass ceramic cuspal deformation (µS) was measured at 100 N and at maximum fracture load using strain gauge. Fracture resistance (N) was measured using a compression test, and the fracture mode was recorded. Finite element analysis was used to evaluate the stress distribution by modified von Mises stress criteria. The tooth strain and fracture resistance data were analyzed using the Tukey test and two-way ANOVA, and the fracture mode was analyzed by the chi-square test (α=0.05). Results The leucite ceramic resulted in higher tooth deformation at 100 N and lower tooth deformation at the maximum fracture load than the lithium disilicate ceramic (P<0.001). The lithium disilicate ceramic exhibited higher fracture resistance than the leucite ceramic (P<0.001). The conservative onlay resulted in higher fracture strength for lithium disilicate ceramic. Finite element analysis results showed the conventional cavity preparation resulted in higher stress concentration in the ceramic restoration and remaining tooth than the conservative onlay preparation. The conservative onlays exhibited increased fracture resistance, reduced stress concentration and more favorable fracture modes. Conclusion Molars restored with lithium disilicate CAD-CAM ceramic onlays exhibited higher fracture resistance than molars restored with leucite CAD-CAM ceramic onlays.


Assuntos
Humanos , Cerâmica/química , Desenho Assistido por Computador , Preparo da Cavidade Dentária/métodos , Porcelana Dentária/química , Silicatos de Alumínio/química , Restaurações Intracoronárias/métodos , Poliuretanos/química , Valores de Referência , Fraturas dos Dentes , Resinas Acrílicas/química , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Estatísticas não Paramétricas , Resinas Compostas/química , Falha de Restauração Dentária , Análise de Elementos Finitos , Análise do Estresse Dentário , Módulo de Elasticidade , Dente Molar
15.
J Appl Oral Sci ; 25(6): 657-665, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29211287

RESUMO

OBJECTIVE: The purpose of this study was to compare laser with conventional techniques in class V cavity preparation in gamma-irradiated teeth. METHODS: Forty extracted human teeth with no carious lesions were used for this study and were divided into two main groups: Group I (n = 20) was not subjected to gamma radiation (control) and Group II (n=20) was subjected to gamma radiation of 60 Gray. Standard class V preparation was performed in buccal and lingual sides of each tooth in both groups. Buccal surfaces were prepared by the Er,Cr:YSGG laser (Waterlase iPlus) 2780 nm, using the gold handpiece with MZ10 Tip in non-contact and the "H" mode, following parameters of cavity preparation - power 6 W, frequency 50 Hz, 90% water and 70% air, then shifting to surface treatment laser parameters - power 4.5 W, frequency 50 Hz, 80% water and 50% air. Lingual surfaces were prepared by the conventional high-speed turbine using round diamond bur. Teeth were then sectioned mesio-distally, resulting in 80 specimens: 40 of which were buccal laser-treated (20 control and 20 gamma-irradiated specimens) and 40 were lingual conventional high-speed bur specimens (20 control and 20 gamma-irradiated specimens). RESULTS: Microleakage analysis revealed higher scores in both gamma groups compared with control groups. Chi-square test revealed no significant difference between both control groups and gamma groups (p=1, 0.819, respectively). A significant difference was revealed between all 4 groups (p=0.00018). CONCLUSION: Both laser and conventional high-speed turbine bur show good bond strength in control (non-gamma) group, while microleakage is evident in gamma group, indicating that gamma radiation had a dramatic negative effect on the bond strength in both laser and bur-treated teeth.


Assuntos
Cárie Dentária/radioterapia , Preparo da Cavidade Dentária/métodos , Infiltração Dentária/radioterapia , Raios gama , Humanos
16.
J. appl. oral sci ; 25(6): 657-665, Nov.-Dec. 2017. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-893675

RESUMO

Abstract Objective: The purpose of this study was to compare laser with conventional techniques in class V cavity preparation in gamma-irradiated teeth. Methods: Forty extracted human teeth with no carious lesions were used for this study and were divided into two main groups: Group I (n = 20) was not subjected to gamma radiation (control) and Group II (n=20) was subjected to gamma radiation of 60 Gray. Standard class V preparation was performed in buccal and lingual sides of each tooth in both groups. Buccal surfaces were prepared by the Er,Cr:YSGG laser (Waterlase iPlus) 2780 nm, using the gold handpiece with MZ10 Tip in non-contact and the "H" mode, following parameters of cavity preparation - power 6 W, frequency 50 Hz, 90% water and 70% air, then shifting to surface treatment laser parameters - power 4.5 W, frequency 50 Hz, 80% water and 50% air. Lingual surfaces were prepared by the conventional high-speed turbine using round diamond bur. Teeth were then sectioned mesio-distally, resulting in 80 specimens: 40 of which were buccal laser-treated (20 control and 20 gamma-irradiated specimens) and 40 were lingual conventional high-speed bur specimens (20 control and 20 gamma-irradiated specimens). Results: Microleakage analysis revealed higher scores in both gamma groups compared with control groups. Chi-square test revealed no significant difference between both control groups and gamma groups (p=1, 0.819, respectively). A significant difference was revealed between all 4 groups (p=0.00018). Conclusion: Both laser and conventional high-speed turbine bur show good bond strength in control (non-gamma) group, while microleakage is evident in gamma group, indicating that gamma radiation had a dramatic negative effect on the bond strength in both laser and bur-treated teeth.


Assuntos
Humanos , Cárie Dentária/radioterapia , Preparo da Cavidade Dentária/métodos , Infiltração Dentária/radioterapia , Raios gama
17.
Photomed Laser Surg ; 35(6): 332-337, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28590837

RESUMO

OBJECTIVE: The aim of this study was to assess and regulate heat generation in the dental pulp cavity and circumambient temperature around a tooth during laser ablation with a femtosecond laser in a confined space. BACKGROUND DATA: The automatic tooth preparing technique is one of the traditional oral clinical technology innovations. In this technique, a robot controlled an ultrashort pulse laser to automatically complete the three-dimensional teeth preparing in a confined space. The temperature control is the main measure for protecting the tooth nerve. METHODS: Ten tooth specimens were irradiated with a femtosecond laser controlled by a robot in a confined space to generate 10 teeth preparation. During the process, four thermocouple sensors were used to record the pulp cavity and circumambient environment temperatures with or without air cooling. A statistical analysis of the temperatures was performed between the conditions with and without air cooling (p < 0.05). RESULTS: The recordings showed that the temperature with air cooling was lower than that without air cooling and that the heat generated in the pulp cavity was lower than the threshold for dental pulp damage. CONCLUSIONS: These results indicate that femtosecond laser ablation with air cooling might be an appropriate method for automatic tooth preparing.


Assuntos
Espaços Confinados , Preparo da Cavidade Dentária/métodos , Esmalte Dentário/efeitos da radiação , Lasers de Estado Sólido/uso terapêutico , Equipamentos Odontológicos de Alta Rotação , Temperatura Alta , Humanos , Técnicas In Vitro , Sensibilidade e Especificidade
18.
Niger J Clin Pract ; 20(6): 734-740, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28656929

RESUMO

PURPOSE: To assess the effect of the erbium:yttrium aluminum garnet (Er:YAG) laser on bond strength of a total-etch adhesive system to the caries-affected dentin on the gingival wall. MATERIALS AND METHODS: Ten human molars with proximal carious lesions were randomly divided into two groups. In the first group, the carious dentin was removed with a bur, whereas in the second group it was removed with the Er:YAG laser. Carious lesions were excavated with one of these two techniques until laser fluorescence values decreased to 15 in the center of the lesions. The teeth were then restored with a total-etch adhesive system (Adper Single Bond 2) and composite resin (Filtek Z250). Five teeth from each group were sectioned to obtain 1 mm2 stick-shaped microtensile specimens from each tooth. Twenty-five specimens were obtained for each group with using this technique. The data were analyzed in independent-samples t-test (α = 0.05). For each removal technique, one sample was analyzed using scanning electron microscopy. RESULTS: No statistically significant differences were found between the bond strength of the Er:YAG laser and the bur-treated groups (P > 0.05). CONCLUSION: The Er:YAG laser treatment did not negatively affect the bonding performance of the total-etch adhesive system to caries-affected dentin on the gingival wall.


Assuntos
Resinas Compostas/química , Preparo da Cavidade Dentária/métodos , Cimentos Dentários/química , Corrosão Dentária/métodos , Lasers de Estado Sólido/uso terapêutico , Resinas Compostas/uso terapêutico , Cárie Dentária/terapia , Preparo da Cavidade Dentária/instrumentação , Cimentos Dentários/uso terapêutico , Corrosão Dentária/instrumentação , Restauração Dentária Permanente , Dentina/química , Dentina/ultraestrutura , Humanos , Microscopia Eletrônica de Varredura , Dente Molar , Distribuição Aleatória , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA