Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Am J Case Rep ; 25: e943108, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38544309

RESUMO

BACKGROUND Coracoid process fractures are uncommon and are often complicated by many types of shoulder girdle injuries. Previous reports have shown that osteosynthesis for isolated coracoid process fractures results in favorable outcomes and high bone union rates. However, owing to the rarity of coracoid process fractures combined with distal clavicle fractures, there are limited data to guide treatment strategies. We report a case of symptomatic nonunion despite performing osteosynthesis for fractures of the coracoid process and distal clavicle. CASE REPORT A 60-year-old man presented with left shoulder pain after falling from the back of a truck. Radiography and computed tomography (CT) findings revealed fractures of the left distal clavicle and coracoid process. We performed plate and costoclavicular fixation using a suture button for the distal clavicle fracture and cannulated cancellous screw fixation for the coracoid process fracture. However, the patient experienced severe pain around the coracoid and had limited shoulder range of motion 1 year postoperatively. CT revealed nonunion of the coracoid process, prompting a recommendation for surgery. However, despite severe persistent functional impairment, the patient refused surgery 1.5 years postoperatively. CONCLUSIONS This case suggests the potential for symptomatic nonunion of the coracoid process when using a suture-button device for a distal clavicle fracture. To prevent postoperative nonunion of the coracoid process, postoperative CT evaluation is necessary. If a symptomatic delayed bone union of coracoid process is observed, considering early removal of the suture button is recommended.


Assuntos
Clavícula , Fraturas Ósseas , Masculino , Humanos , Pessoa de Meia-Idade , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Clavícula/lesões , Processo Coracoide/diagnóstico por imagem , Processo Coracoide/cirurgia , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/métodos , Suturas , Resultado do Tratamento
2.
Arthroscopy ; 40(4): 1311-1324.e1, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37827435

RESUMO

PURPOSE: To analyze radiographic outcomes by conventional radiography, computed tomography (CT), or both and complication rates of open coracoid transfer at a minimum of 12-months follow-up. METHODS: A literature search was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, using PubMed, Medline (Ovid), and EMBASE library databases. Inclusion criteria were clinical studies reporting on open Latarjet as the primary surgical procedure(revision coracoid transfer after failed prior stabilization excluded) with postoperative radiographic outcomes at a minimum mean 1-year follow-up. Patient demographics, type of postoperative imaging modality, and radiographic outcomes and complications including graft union, osteoarthritis, and osteolysis were systematically reviewed. Data were summarized as ranges of reported values for each outcome metric. Each radiographic outcome was graphically represented in a Forest plot with point estimates of the incidence of radiographic outcomes with corresponding 95% confidence intervals and I2. RESULTS: Thirty-three studies met inclusion criteria, with a total of 1,456 shoulders. The most common postoperative imaging modality was plain radiography only (n = 848 [58.2%]), both CT and radiography (n = 287 [19.7%]), and CT only (n = 321 [22.1%]). Overall, the reported graft union rate ranged from 75% to 100%, of which 79.8% (n = 395) were detected on plain radiography. The most common reported postoperative radiographic complications after the open coracoid transfer were osteoarthritis (range, 0%-100%, pooled mean 28%), graft osteolysis (range, 0%-100%, pooled mean 30%), nonunion (range, 0%-32%, pooled mean 5.1%), malpositioned graft (range, 0%-75%, pooled mean 14.75%), hardware issues (range, 0%-9.1%, pooled mean 5%), and bone block fracture (range, 0%-8%, pooled mean 2.1%). Graft healing was achieved in a majority of cases (range, 75%-100%). CONCLUSION: Postoperative radiographic outcomes after open coracoid transfer vary greatly in definition, classification, and imaging modality of choice. Greater consistency in postoperative radiographic outcomes is essential to evaluate graft healing, osteolysis, and nonunion. LEVEL OF EVIDENCE: Level IV, systematic review of Level III-IV studies.


Assuntos
Fraturas Ósseas , Instabilidade Articular , Osteoartrite , Osteólise , Luxação do Ombro , Articulação do Ombro , Humanos , Articulação do Ombro/cirurgia , Instabilidade Articular/cirurgia , Ombro/cirurgia , Luxação do Ombro/cirurgia , Osteoartrite/diagnóstico por imagem , Osteoartrite/cirurgia , Osteoartrite/complicações , Fraturas Ósseas/complicações , Processo Coracoide/cirurgia , Processo Coracoide/transplante
3.
Tech Hand Up Extrem Surg ; 27(3): 148-150, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36745748

RESUMO

A fracture of the tip of the coracoid is a rare but challenging fracture. A surgical indication is required in case of a displaced fracture. Screws and suture anchors often do not offer a reliable fixation in the case of very small fragments. We describe our hardwareless technique that consists of an osteosuture with a 90-degree suture threads configuration that we called the x-mas box technique. This procedure is cost-effective and it provides stable fixation and low complications rate.


Assuntos
Processo Coracoide , Fraturas Ósseas , Humanos , Processo Coracoide/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Extremidade Superior , Âncoras de Sutura
4.
Arch Orthop Trauma Surg ; 143(2): 959-965, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35344065

RESUMO

INTRODUCTION: Coracoid fractures after arthroscopic treatment of acromioclavicular (AC) joint separations lead to poor clinical outcomes. In this study, different configurations of bone tunnels in the lateral clavicle and coracoid were examined concerning the amount of stress induced in the coracoid. METHODS: An authentic 3D finite element model of an ac joint was established. Three 2.4 mm bone tunnels were inserted in the lateral clavicle, which were situated above, medially and laterally of the coracoid. Then, two 2.4 mm bone tunnels were inserted in the latter, each simulating a proximal and a distal suture button position. Von Mises stress analyses were performed to evaluate the amount of stress caused in the coracoid process by the different configurations. Then, a clinical series of radiographs was examined, the placement of the clavicle drill hole was analyzed and the number of dangerous configurations was recorded. RESULTS: The safest configuration was a proximal tunnel in the coracoid combined with a lateral bone tunnel in the clavicle, leading to an oblique traction at the coracoid. A distal bone tunnel in the coracoid and perpendicular traction as well as a proximal tunnel in the coracoid with medial traction caused the highest stresses. Anatomical placement of the clavicle drill hole does lead to configurations with smaller stresses. CONCLUSION: The bone tunnel placement with the smallest amount of shear stresses was found when the traction of the suture button was directed slightly lateral, towards the AC joint. Anatomical placement of the clavicle drill hole alone was not sufficient in preventing dangerous configurations. LEVEL OF EVIDENCE: Controlled laboratory study.


Assuntos
Articulação Acromioclavicular , Fraturas Ósseas , Luxações Articulares , Procedimentos de Cirurgia Plástica , Humanos , Processo Coracoide/cirurgia , Análise de Elementos Finitos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fraturas Ósseas/etiologia , Articulação Acromioclavicular/diagnóstico por imagem , Articulação Acromioclavicular/cirurgia , Clavícula/cirurgia , Ligamentos Articulares/cirurgia , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/etiologia , Luxações Articulares/cirurgia
5.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 36(9): 1072-1077, 2022 Sep 15.
Artigo em Chinês | MEDLINE | ID: mdl-36111467

RESUMO

Objective: To evaluate the short-term effectiveness of modified arthroscopic Latarjet procedure with double EndoButtons for recurrent anterior shoulder dislocation. Methods: Between January 2019 and November 2020, 36 patients with recurrent anterior shoulder dislocation were treated by modified arthroscopic Latarjet procedure with double EndoButtons. There were 26 males and 10 females, with an average age of 27.8 years (range, 18-36 years). The number of shoulder dislocations ranged from 3 to 12 times, with an average of 6.5 times. The disease duration ranged from 5 to 36 months, with an average of 16.2 months. Preoperative shoulder fear test was positive, and the Beighton score of joint relaxation was 0-4, with an average of 1.3. Imaging examination showed that the defect width of the ipsilateral glenoid bone was 16%-28%, with an average of 21.5%. Postoperative complications, recurrent dislocation, subluxation, and instability of shoulder joint were recorded. Shoulder range of motion was examined, including forward flexion, external rotation at side, external rotation at 90° abduction, and internal rotation. Shoulder joint function was evaluated by Walch-Duplay score, American Association for Shoulder and Elbow Surgery Score (ASES), and ROWE score. X-ray film and CT images were taken to observe the shaping of coracoid process graft. Results: All incisions healed by first intention, and no vascular or nerve injury occurred. All patients were followed up 12-28 months, with an average of 19.9 months. During follow-up, no shoulder dislocation recurred, and shoulder fear test was negative. At last follow-up, there was no significant difference in shoulder forward flexion, external rotation at side, external rotation at 90° abduction, and internal rotation when compared with preoperative values (P>0.05). The Walch-Duplay score, ASES score, and ROWE score of shoulder function significantly improved (P<0.05). Postoperative imaging examination showed that coracoid process graft was at the same level with the glenoid in 33 cases (91.7%), medial in 1 case (2.8%), and lateral in 2 cases (5.6%); the center of coracoid process graft was mainly located between 3 to 5 o'clock in 33 cases (91.7%), higher than 3 o'clock in 1 case (2.8%), and lower than 5 o'clock in 2 cases (5.6%). There was no obvious glenohumeral joint degeneration during follow-up, and the coracoid process graft gradually formed concentric circles with the humeral head. Conclusion: The modified arthroscopic Latarjet procedure with double EndoButtons can effectively treat recurrent anterior shoulder dislocation, and the short-term effectiveness is satisfactory, and the position of coracoid process graft is accurate.


Assuntos
Luxação do Ombro , Articulação do Ombro , Adulto , Artroplastia/métodos , Artroscopia/métodos , Processo Coracoide/cirurgia , Feminino , Humanos , Masculino , Luxação do Ombro/cirurgia , Articulação do Ombro/cirurgia
6.
Orthop Surg ; 14(10): 2692-2700, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36093615

RESUMO

OBJECTIVE: An agreement has not been reached on optimal locations of bone tunnels for coracoclavicular ligament (CCL) reconstruction for acromioclavicular joint dislocation (ACD). This study aims to identify the convergence point (cP) between the coracoid process and clavicle in the Chinese population to assist surgeons in reconstructing the CCL for ACD. METHODS: From 2014 to 2020, 483 CT scans of the shoulders of 270 male and 213 female patients (247 right and 236 left shoulders) were collected and studied retrospectively. By overlapping the images of the transverse plane of the coracoid process and the clavicle, points a and b, and the midpoint ab (cP) were determined. Then, a series of parameters through point cP in the transverse and sagittal planes were measured. In the transverse plane this included the distance from point cP to the tip of the coracoid process (cP-cor),the distance between the medial and lateral margins of the coracoid process through point cP (Med-lat cor), the distance from point cP to the acromioclavicular joint (cP-ac), and the distance between the anteroposterior margin of the clavicle through point cP (Ap-clav). In the sagittal plane, this included the craniocaudal segment of the coracoid process (Cc-cor), and the craniocaudal segment of the clavicle (Cc-clav). The sex and side differences of these measurements were also analyzed by two radiologists. RESULTS: Based on the following measurements, point cP was determined. For male patients, the cP-cor was 28.02 ± 3.43 mm, Med-lat cor was 22.78 ± 2.80 mm, Cc-cor was 15.11 ± 2.13 mm, cP-ac was 29.24 ± 3.84 mm, Ap-clav was 18.27 ± 2.46 mm, and Cc-clav was 10.09 ± 1.56 mm. For female patients, the cP-cor was 25.20 ± 3.26 mm, Med-lat cor was 20.21 ± 2.97 mm, Cc-cor was 13.03 ± 1.77 mm, cP-ac was 26.66 ± 3.45 mm, Ap-clav was 16.10 ± 2.30 mm, and Cc-clav was 8.91 ± 1.40 mm. All the measurements of female patients were lower than those of male patients (p < 0.01). Between sides, only cP-ac of the left shoulders was significantly lower than those of the right shoulders (p < 0.05), with no significant differences in other parameters between sides (p > 0.05). CONCLUSION: The results of this study identified the locations of bone tunnel-cP in the coracoid process and clavicle for the CCL reconstruction in ACD. Moreover, the findings indicated that surgeons should be more cautious in operating on female patients and that the cP-ac of left shoulders should be set lower than that of right shoulders.


Assuntos
Articulação Acromioclavicular , Luxação do Ombro , Articulação Acromioclavicular/diagnóstico por imagem , Articulação Acromioclavicular/cirurgia , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Processo Coracoide/diagnóstico por imagem , Processo Coracoide/cirurgia , Feminino , Humanos , Ligamentos Articulares/diagnóstico por imagem , Ligamentos Articulares/cirurgia , Masculino , Estudos Retrospectivos , Luxação do Ombro/cirurgia , Tomografia Computadorizada por Raios X
7.
J Orthop Surg Res ; 17(1): 371, 2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-35907891

RESUMO

BACKGROUND: We created patient-based 3D finite-element (FE) models that simulate the congruent-arc Latarjet (CAL) and traditional Latarjet (TL) procedures and then compared their stress distribution patterns with different arm positions and glenoid defects. METHODS: The computed tomography data of 10 adult patients (9 men and 1 woman, ages: 18-50 years) were used to develop the 3D FE glenohumeral joint models. Twenty-five and 35% bony defects were created on the anterior glenoid rim, and the coracoid process was transferred flush with the glenoid by the traditional and congruent-arc techniques using two half-threaded screws. A load was applied to the greater tuberosity toward the center of the glenoid, and a tensile force (20 N) was applied to the coracoid tip along the direction of the conjoint tendon. The distribution patterns of the von Mises stress in the traditional and congruent-arc Latarjet techniques were compared. RESULTS: The mean von Mises on the graft was significantly greater for the TL technique than for the CAL. While the von Mises stress was greater in the distal medial part of the graft in the TL models, a higher stress concentration was observed in the distal lateral edge of the coracoid graft in the CAL models. The proximal medial part of the graft exhibited significantly lower von Mises stress than the distal medial part when compared according to technique, defect size, and arm position. Increasing the glenoid defect from 25 to 35% resulted in a significant increase in stress on the lateral side of the graft in both models. CONCLUSION: The stress distribution patterns and stress magnitude of the coracoid grafts differed according to the procedure. Due to placing less stress on the proximal-medial part of the graft, the CAL technique may lead to insufficient stimulation for bone formation at the graft-glenoid interface, resulting in a higher incidence of graft osteolysis. Clinical relevance The CAL technique may lead to a higher incidence of graft osteolysis. LEVEL OF EVIDENCE: Basic Science Study; Computer Modeling.


Assuntos
Instabilidade Articular , Osteólise , Articulação do Ombro , Adolescente , Adulto , Transplante Ósseo/métodos , Processo Coracoide/diagnóstico por imagem , Processo Coracoide/cirurgia , Feminino , Humanos , Instabilidade Articular/cirurgia , Masculino , Pessoa de Meia-Idade , Escápula/diagnóstico por imagem , Escápula/cirurgia , Articulação do Ombro/cirurgia , Adulto Jovem
8.
Arch Orthop Trauma Surg ; 142(3): 387-393, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33113015

RESUMO

INTRODUCTION: Joint replacement surgery as a treatment for glenohumeral arthritis with glenoid bone loss is challenging. The aim of this study is to offer an anatomical orientation for glenoid reconstruction. METHODS: In this study, we measured size, inclination and version of the glenoid surface, as well as the distance between the articular line of the glenoid, base of the coracoid process, and acromion using computer tomographic (CT) imaging of 131 study participants aged 19-88 years in the period of 2010-2013. RESULTS: We measured a mean distance of 6.5 ± 0.2 mm from the glenoid articular line to the base of the coracoid process in the transverse CT plane. Body height has shown no significant impact on the glenoid morphology. We observed significant differences between males and females: The glenoid appeared to be located 5.2 ± 0.9 mm higher and the humeral head was 4.5 ± 0.7 mm larger in male subjects compared with females (r = .699; p < .01). CONCLUSION: In our study, the base of the coracoid offers an anatomical reference during reconstruction of the glenoid in primary and revision shoulder arthroplasty. As only 2D-CT imaging allows for accurate assessment of glenoid bone defects, we consider conventional X-ray imaging insufficient for proper preoperative planning before shoulder arthroplasty. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Ombro , Artroplastia de Substituição , Cavidade Glenoide , Articulação do Ombro , Adulto , Idoso , Idoso de 80 Anos ou mais , Computadores , Processo Coracoide/cirurgia , Feminino , Cavidade Glenoide/diagnóstico por imagem , Cavidade Glenoide/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Tomografia Computadorizada por Raios X , Adulto Jovem
9.
J Shoulder Elbow Surg ; 31(3): 623-628, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34487823

RESUMO

Nineteen patients presented with an unsightly deformity of the shoulder, pain or discomfort at the medial scapular border, pseudo nonparalytic scapular winging, and thoracic outlet symptoms after excessive resection of the clavicle for either complete acromioclavicular separation or displaced fracture of the outer clavicle, which allows the scapula and shoulder to rotate anteriorly and inferiorly on the chest creating traction on the medial scapular muscles and the brachial plexus resulting in pseudo nonparalytic winging and thoracic outlet symptoms. RESULTS: All underwent transfer of the coracoid process with the attached conjoined tendon to the end of the clavicle, restoring length and alignment. Eighteen patients were evaluated at a mean of 13.3 years. Seventeen had resolution of symptoms, restored alignment of the clavicle with the shoulder, improved appearance, healed transfer, and were pleased with the outcome. One patient was lost to follow-up but was considered a failure at his last visit. In a second patient, the transfer healed in a tilted position and the patient was dissatisfied with the appearance but otherwise had resolution of his symptoms. The mean American Shoulder and Elbow Surgeons Outcome Score improved from 53.2 preoperatively to 87.4 postoperatively (P < .02). CONCLUSION: This is the first report of using this transfer to restore length and alignment of an excessively short, unstable clavicle. The transfer succeeded in improving the appearance and symptoms in this complication of an excessively short, unstable clavicle.


Assuntos
Clavícula , Fraturas Ósseas , Clavícula/cirurgia , Processo Coracoide/cirurgia , Fraturas Ósseas/cirurgia , Humanos , Escápula/cirurgia , Tendões
10.
J Orthop Surg Res ; 16(1): 58, 2021 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-33446228

RESUMO

BACKGROUND: Fractures of the base of the coracoid process are relatively rare, but an increasing number of studies have reported using screws to fix coracoid process base fractures. This study was performed to simulate the surgical procedure and obtain the ideal diameter, length, insertion point and angle of the screw from a 3-D axial perspective in Chinese patients. METHODS: We randomly collected right scapula computed tomography (CT) scans from 100 adults. DICOM-formatted CT scan images were imported into Mimics software. A 3D digital model of the right scapula was established. Two virtual cylinders representing two screws were placed from the top of the coracoid process to the neck of the scapula and across the base of the coracoid process to fix the base of the coracoid process. The largest secure diameters and lengths of the virtual screws were measured. The positions of the insertion points and the directions of the screws were also examined. RESULTS: The screw insertion safe zone can exhibit an irregular fusiform shape according to the reconstructed scapula model. The mean maximum diameters of the medial and lateral screws were 7.08 ± 1.19 mm and 7.34 ± 1.11 mm, respectively. The mean maximum lengths of the medial and lateral screws were 43.11 ± 6.31 mm and 48.16 ± 6.94 mm, respectively. A screw insertion corridor with a diameter of at least 4.5 mm was found in all patients. We found sex-dependent differences in the mean maximum diameters and maximum lengths of the two screws. The positions of the two insertion points were statistically different across sexes. CONCLUSIONS: The study provides a valuable guideline for determining the largest secure corridor for two screws in fixing a fracture at the base of the coracoid process. For ideal screw placement, we suggest individualised preoperative 3D reconstruction simulations. Further biomechanical studies are needed to verify the function of the screws.


Assuntos
Parafusos Ósseos , Processo Coracoide/lesões , Processo Coracoide/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Povo Asiático , Processo Coracoide/diagnóstico por imagem , Feminino , Fraturas Ósseas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Escápula/diagnóstico por imagem , Caracteres Sexuais , Adulto Jovem
11.
Knee Surg Sports Traumatol Arthrosc ; 29(7): 2103-2109, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32691091

RESUMO

PURPOSE: The optimal (SBJI) surgical treatment for acute acromioclavicular (AC) joint disruption remains controversial. What is being presented is the long-term functional outcomes of a double cross-looped coracoclavicular (CC) suture technique with the intention of restoring both anteroposterior and superior displacement of the clavicle. METHODS: Between 2007 and 2016, 81 patients underwent surgical reconstruction for acute acromioclavicular joint (AC) disruption in two orthopaedic centers. Two patients died for reasons unrelated to the treatment, and seven missed the final follow-up appointment, leaving 72 patients (67 males; 5 females; age 37 ± 12.4; range 15-64 years) for clinical and radiological assessments. All cases were classified according to the Rockwood classification as type III (n = 34), IV (n = 14) or V (n = 24). The dislocation was repaired with double cross-looped CC fixation using four Ethibond sutures passing underneath the coracoid and through a 4.5 mm drill hole in the clavicle in opposing directions to control both anteroposterior and vertical displacement. Radiological investigation preoperatively and at the last follow-up included anteroposterior and/or Zanca views, axillary or Alexander views, and comparative stress radiography of both AC joints. Patients were evaluated clinically with the Constant-Murley score (CMS) and Acromio Clavicular Joint Instability Score (ACJIS). Loss of reduction, subluxation, CC ligament ossification, post-traumatic arthritis, and peri-implant fractures were also recorded. RESULTS: Seventy-two patients were available for the last clinical and radiological evaluations. At a median follow-up period of 6.3 ± 2.1 years (range 3-12 years), the CMS and ACJIS were 92.1 ± 7.2 (range 60-100 points) and 90.4 ± 8.6 (range 45-100 points), respectively. Complications included 9 (12.5%) patients with slight loss of reduction, 2 (1.7%) with dislocation recurrence, 1 (1.3%) with superficial infection, 1 (1.3%) with a fracture of the lateral end of the clavicle, and 2 (1.7%) with persistent tenderness in the AC joint. The incidence of periarticular ossification was 22.4% and did not affect the final outcome. CONCLUSIONS: This technique represents an effective and low-cost treatment for acute AC joint separations. LEVEL OF EVIDENCE: IV.


Assuntos
Clavícula/lesões , Clavícula/cirurgia , Processo Coracoide/lesões , Processo Coracoide/cirurgia , Luxações Articulares/cirurgia , Procedimentos Ortopédicos/métodos , Técnicas de Sutura , Adolescente , Adulto , Traumatismos em Atletas/diagnóstico por imagem , Traumatismos em Atletas/cirurgia , Clavícula/diagnóstico por imagem , Processo Coracoide/diagnóstico por imagem , Feminino , Humanos , Luxações Articulares/diagnóstico por imagem , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Ligamentos Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Procedimentos Ortopédicos/efeitos adversos , Complicações Pós-Operatórias , Radiografia , Resultado do Tratamento , Adulto Jovem
12.
Knee Surg Sports Traumatol Arthrosc ; 29(7): 2064-2069, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32382804

RESUMO

PURPOSE: Neer type II distal clavicle fractures are associated with a high rate of non-union or malunion due to impaired coracoclavicular ligament stability. The purpose of this study was to assess the clinical and radiological outcomes of arthroscopically assisted indirect osteosynthesis for type II distal clavicle fractures using a cortical suture button device. METHODS: Seventeen patients Neer type II fractures of the distal clavicle were treated surgically using cortical suture button fixation between 2012 and 2017. The clinical and radiological results were assessed using the American Shoulder and Elbow Surgeons Shoulder Score (ASES), Constant-Murley score and visual analogue scale (VAS) score. RESULTS: Anatomic reduction and bone healing were achieved in all patients at the final follow-up. The median age of the patients was 31 years (range 19-57). The mean follow-up was 25.9 months (range 14-64). The average delay before surgery was 2 days (range 1-4). At the final follow-up, the mean ASES, Constant-Murley score and VAS score were 92.6 ± 3.2 (range 84.9-96.6), 96.2 ± 2.4 (range 92-100) and 0.47 ± 0.51 (range 0-1), respectively. All patients were able to resume work as well as sport activities. The postoperative complications included two coracoid process fractures, and none of the patients required additional surgery related to the index procedure. CONCLUSION: All arthroscopic coracoclavicular button fixation of Neer type II distal clavicle fractures would provide sufficient stability and union with satisfactory radiological and clinical outcomes. This arthroscopic fixation technique would be more efficient than other osteosynthesis methods because it is a minimally invasive surgery with a low complication rate. LEVEL OF EVIDENCE: III.


Assuntos
Artroscopia/métodos , Clavícula/lesões , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Técnicas de Sutura/instrumentação , Articulação Acromioclavicular/cirurgia , Adulto , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Processo Coracoide/cirurgia , Feminino , Seguimentos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/diagnóstico por imagem , Humanos , Ligamentos Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Complicações Pós-Operatórias/epidemiologia , Radiografia/métodos , Resultado do Tratamento , Adulto Jovem
13.
Arthroscopy ; 37(2): 470-476, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33022364

RESUMO

PURPOSE: To assess the proximity of neurovascular structures in a layered approach during medial portal placement and determine standardized measurements for establishing a portal medial to the coracoid used in arthroscopic Latarjet-type procedures. METHODS: Twelve shoulders (6 right and 6 left) in 6 fresh frozen cadaveric torsos were mounted in the modified beach-chair position. A standard posterior portal and 3 anterior portals-central, lateral, and medial-were used. A long spinal needle was placed along the path of the medial portal to the lateral tip of the coracoid, superficial to the conjoined tendon and pectoralis minor. A second long spinal needle was directed toward the medial base of the coracoid, penetrating the pectoralis minor. Superficial and deep plane dissections were performed, and distances to surrounding neurovascular structures were recorded. RESULTS: In the superficial plane, the cephalic vein and lateral pectoral nerve were located a mean distance (± standard deviation) of 4.6 ± 1.9 mm and 9.4 ± 2.6 mm from the spinal needle, respectively. In the deep plane, the axillary nerve was 24.9 ± 7.4 mm from the needle; the lateral cord of the brachial plexus, 25.5 ± 8.1 mm; the axillary artery, 34.1 ± 6.0 mm; and the musculocutaneous nerve, 42.2 ± 9.2 mm. The portal was consistently established 45.0 to 50.0 mm distal and 30.0 to 35.0 mm medial to the coracoid, which was a minimum distance of 10 mm to the lateral pectoral nerve. CONCLUSIONS: In a cadaveric model, the creation of a medial trans-pectoralis major portal used in the arthroscopic Bankart-Bristow-Latarjet procedure can avoid compromise of vital neurovascular structures, alleviating concerns of creating a portal medial to the coracoid. Portal placement 45.0 to 50.0 mm distal and 30.0 to 35.0 mm medial to the palpable tip of the coracoid process may be a safe approach to perform the arthroscopic Bankart-Bristow-Latarjet procedure. CLINICAL RELEVANCE: Creation of a portal medial to the level of the coracoid may pose a risk to neurovascular structures. This cadaveric study establishes a working zone for medial trans-pectoralis portal placement, which avoids vital neurovascular structures, and provides standardized measurements for establishing this portal for use in the arthroscopic Bankart-Bristow-Latarjet procedure.


Assuntos
Artroscopia/métodos , Músculos Peitorais/cirurgia , Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Processo Coracoide/anatomia & histologia , Processo Coracoide/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Músculos Peitorais/anatomia & histologia , Ombro/anatomia & histologia , Tendões/anatomia & histologia , Tendões/cirurgia
14.
J Bone Joint Surg Am ; 103(1): 15-22, 2021 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-33165127

RESUMO

BACKGROUND: The prevalence of nonunion after the Latarjet procedure remains high. The purpose of the present study was to investigate healing and clinical outcomes after a novel arthroscopic coracoid process transfer procedure. METHODS: Sixty-three patients who underwent the arthroscopic inlay Bristow procedure combined with Bankart repair were identified, and 51 patients who met the inclusion criteria were enrolled in this study. The key feature of this technique was that the coracoid process was trimmed and fixed into a trough (5 to 10 mm deep) in the glenoid neck with a metal screw. Bone graft union and positioning accuracy were assessed with use of postoperative computed tomography (CT) imaging. Clinical examinations, return to sport, and functional scores (American Shoulder and Elbow Surgeons [ASES] and Rowe scores) were recorded. RESULTS: The mean duration of follow-up (and standard deviation) was 41.5 ± 7.7 months (range, 36 to 48 months). Postoperative CT scans showed that the position of coracoid graft was at 4:10 (from 3:50 to 5:00) (referencing the right shoulder) in the sagittal view. The α angle was 16.4° ± 9.5°, with 4 (7.8%) of 51 screws being over-angulated (α > 25°). On the axial view, the graft position was considered to be flush in 33 patients (64.7%), medial in 11 (21.6%), congruent in 7 (13.7%), and lateral or too medial in none. At 1 year, the coracoid graft had healed in 49 patients (96.1%) and had failed to unite in 2 patients. CT scanning, performed for 47 patients, showed grade-0 osteolysis in 9 patients, grade-1 osteolysis in 21 patients, and grade-2 osteolysis in 17 patients. At the time of the latest follow-up, there was a significant increase in the Rowe score (from 35.5 ± 8.3 to 95.7 ± 7.2) and the ASES score (from 71.2 ± 9.7 to 91.5 ± 4.4), and 87.0% of patients were able to return to sport. No arthropathy was observed in any patient. CONCLUSIONS: After a minimum 3-year follow-up, the arthroscopic inlay Bristow procedure resulted in a high rate of graft healing, excellent clinical outcomes, and a high rate of return to sports. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia/métodos , Luxação do Ombro/cirurgia , Fraturas do Ombro/cirurgia , Articulação do Ombro/cirurgia , Adolescente , Adulto , Artroplastia/reabilitação , Artroscopia , Transplante Ósseo/métodos , Processo Coracoide/diagnóstico por imagem , Processo Coracoide/cirurgia , Processo Coracoide/transplante , Seguimentos , Humanos , Imageamento Tridimensional , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Pessoa de Meia-Idade , Estudos Prospectivos , Recuperação de Função Fisiológica , Recidiva , Volta ao Esporte , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/reabilitação , Fraturas do Ombro/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Cicatrização , Adulto Jovem
15.
J Shoulder Elbow Surg ; 30(7): 1503-1510, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33157238

RESUMO

BACKGROUND: The success of the modified Latarjet procedure depends on proper sizing of the coracoid graft. There is no information available regarding the morphometric relationship between the glenoid cavity and the coracoid process for the South African population. This study aims at measuring the relationship between the glenoid and coracoid morphometries and investigates their gender-related differences. METHODS: Glenohumeral computerized tomography scans of 100 consecutive patients were considered for this study. Morphometric measurements were performed after aligning the coracoid and glenoid in their optimum orientation. These measurements were performed by 2 independent observers. The ratio between glenoid and coracoid measurements was calculated and statistically compared using the Mann-Whitney U test. Intraclass correlation coefficients were calculated to analyze interobserver reliability. All the statistical tests were performed in SPSS v.26, and power calculations in G∗Power v.3.1. RESULTS: An average intraclass correlation coefficient value of 0.79 suggested that the interobserver reliability was good. Except for coracoid length, statistically significant (P < .05) gender differences were observed for all the other morphometries. The coracoid width (16.5 ± 1.4 mm vs. 14.7 ± 1.4 mm) and height (13.6 ± 1.6 mm vs. 10.5 ± 1.5 mm) differed between genders by 1.8 and 3.1 mm, respectively. The glenoid anteroposterior (AP) (25.3 ± 2.9 mm vs. 23.2 ± 2.4 mm) and superioinferior (36.9 ± 1.9 mm vs. 33.7 ± 2.6 mm) measurements differed by 2.1 and 3.3 mm, respectively, between the males and the females. The ratio between the AP width of the glenoid and the coracoid height was also found to be significantly different (P < .05) between the gender groups. These morphometric ratios for the coracoid width (0.66 ± 0.09 mm vs. 0.64 ± 0.08 mm) and the coracoid height (0.55 ± 0.09 mm vs. 0.46 ± 0.07 mm) differed between genders by 0.02 and 0.09, respectively. CONCLUSION: Measurements taken from computerized tomography scans showed significant differences between genders in absolute measurements and in the ratio of the coracoid height to the glenoid AP distance. This could have implications on the ability of the Latarjet procedure to compensate for bone loss in female patients.


Assuntos
Instabilidade Articular , Articulação do Ombro , Transplante Ósseo , Processo Coracoide/diagnóstico por imagem , Processo Coracoide/cirurgia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Escápula/diagnóstico por imagem , Escápula/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Tomografia Computadorizada por Raios X
17.
Arch Orthop Trauma Surg ; 140(12): 1993-2001, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32870335

RESUMO

INTRODUCTION: Congruent arc Latarjet procedure involves rotating the coracoid process so that its inferior surface is flush with the glenoid face, owing to their matching radius of curvature (ROC). However, there has been no cadaveric study to actually measure and compare the ROC of coracoid with glenoid, especially in Indian population. MATERIALS AND METHODS: 44 shoulders were dissected in 24 cadavers to measure usable length of coracoid process, width, height, ROC of coracoid and glenoid as well as ulnar length (as proxy of cadaver height). Critical coracoid height and length were estimated based on screw sizes of 2.7 mm, 3.5 mm, 4 mm and 4.5 mm, and pair concordance between height and length calculated. ROC of coracoid and glenoid were compared to measure extent of congruency. RESULTS: The mean usable length of coracoid process, width and height at mid-point were 21.8 mm, 13.7 mm and 8.6 mm, respectively. Out of the different screw sizes, 2.7 mm screws were found safe in 82% shoulders. 24 coracoid-glenoid pairs fulfilled the operational definition (≤ 5 mm) of congruency while rest 20 were seemingly incongruent chiefly due to coracoid variations, with mean ROC difference 4.13 mm (95% CI 1.51-6.74 mm). The ulnar length was significantly smaller in the incongruent ROC group (p = 0.0002). CONCLUSIONS: The available length as well as height of the transferred coracoid must be considered when deciding optimum diameter fixation screws in Latarjet procedure. Owing to smaller anatomic dimensions of coracoid in Indian population, 2.7-mm screws provide the safest fixation option. Also, the ROC of coracoid and glenoid does not match in substantial proportion of the cadavers. Pre-operative planning should include a CT-based assessment of glenoid and coracoid dimensions to decide the technique of Latarjet procedure and the optimum diameter fixation screws required.


Assuntos
Artroplastia/métodos , Pesos e Medidas Corporais/métodos , Processo Coracoide , Instabilidade Articular , Escápula , Articulação do Ombro , Cadáver , Processo Coracoide/patologia , Processo Coracoide/cirurgia , Feminino , Humanos , Instabilidade Articular/diagnóstico , Instabilidade Articular/cirurgia , Masculino , Osteotomia/métodos , Planejamento de Assistência ao Paciente/normas , Cuidados Pré-Operatórios/métodos , Escápula/patologia , Escápula/fisiopatologia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Articulação do Ombro/cirurgia , Tomografia Computadorizada por Raios X
18.
Orthop Surg ; 12(5): 1526-1530, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32975039

RESUMO

BACKGROUND: Multiple disruptions of the superior shoulder suspensory complex (SSSC) involving more than two components are extremely rare. In some extreme situations, three components of the SSSC structure can be involved. The ideal treatment for this type of injury is debatable. CASE PRESENTATION: A 21-year-old woman was referred to our emergency center following a traffic accident. A three-dimensional CT scan showed triple disruption of the SSSC involving concomitant ipsilateral fractures of the coracoid, the acromion, and the distal clavicle. The connection between the upper limber and the axial skeleton was destroyed. There was no evidence of associated injury and the neurovascular examination of the injured upper limb was normal. The patient underwent an open reduction and internal fixation to restore the anatomic integrity of the SSSC. The arm was supported in a broad arm sling for 2 weeks after surgery. Gentle passive range of motion activity under analgesic was encouraged from the second day postoperatively. One year and half after the operation, the patient had regained pain free and unrestricted shoulder stability and mobility. CONCLUSION: The manifestations of multiple disruptions of the SSSC may be variable. This case illustrated the challenges of treating the multiple disruption of the SSSC structure. It also showed that surgical intervention for this rare combination injury yields an excellent functional result. The good outcome achieved in this patient demonstrates that surgical intervention might be an optional resolution for multiple disruptions of the SSSC.


Assuntos
Acrômio/cirurgia , Clavícula/cirurgia , Processo Coracoide/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Lesões do Ombro/cirurgia , Acrômio/lesões , Clavícula/lesões , Processo Coracoide/lesões , Feminino , Humanos , Adulto Jovem
19.
Orthop Surg ; 12(5): 1478-1488, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32975042

RESUMO

OBJECTIVE: To investigate the clinical efficacy and outcomes of the coracoid osteotomy with or without Bristow-Latarjet procedures in the treatment of chronic anterior shoulder dislocation (CASD). METHODS: Between January 2013 and January 2019, 20 shoulders of 18 patients who were diagnosed with chronic anterior dislocation and underwent open reduction in our trauma center were retrospectively studied. Open coracoid osteotomy with Bristow-Latarjet procedures were performed on 16 shoulders and open coracoid osteotomy without Bristow-Latarjet procedures were performed on four shoulders. Open coracoid osteotomy with or without Bristow-Latarjet procedures were chosen on the basis of the stability of the shoulder after reduction. Outcomes were assessed preoperatively and postoperatively with the visual analog scale (VAS) for pain, the American Shoulder and Elbow Surgeons (ASES) score, the University of California Los Angeles (UCLA) shoulder rating scale, and the range of motion (ROM) for shoulder activity. RESULTS: There were three males and 15 females with an average age of 60.94 ± 2.69 years. The time between dislocation and treatment ranged from 21 to 240 days with an average of 73.3 ± 14.4 days. All patients were available for a mean follow-up of 15.2 ± 4.3 months. No procedure-related death or incision-related superficial or deep tissue infection was identified in all cases. No iatrogenic neurovascular injuries or fractures were found in this study. At the time of 12 months follow-up, the range of motion and the shoulder functional evaluation (VAS [P < 0.001], ASES [P < 0.001], and UCLA score [P < 0.001]) in patients who underwent Bristow-Latarjet procedures were significantly improved. Subluxation after surgical procedure was found and confirmed in one patient and this patient refused to undergo revision surgery. According to the Samilson and Prieto classification system, 16 shoulders were assessed as grade 0, three shoulders were grade 1, one shoulder was grade 2. CONCLUSIONS: Coracoid osteotomy with or without Bristow-Latarjet procedure yielded an acceptable clinical result in this study. This method has the advantages of enlarging the exposure of surgical field, assisting reduction of shoulder, and convenient conversion to Bristow-Latarjet procedure. It is an efficient and reliable method for treatment of chronic anterior shoulder dislocation. A 69-year-old woman diagnosed with right chronic anterior shoulder dislocation with large Hill-Sachs lesion. The latarjet procedure with remplissage technique was applied for this patient.


Assuntos
Processo Coracoide/cirurgia , Procedimentos Ortopédicos/métodos , Osteotomia/métodos , Luxação do Ombro/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Amplitude de Movimento Articular , Estudos Retrospectivos , Inquéritos e Questionários
20.
J Shoulder Elbow Surg ; 29(10): 2143-2148, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32423790

RESUMO

BACKGROUND: Acromioclavicular joint separations continue to be a challenge for surgeons, and modern arthroscopically assisted techniques are becoming increasingly widespread. The aim of this study is to evaluate if the use of a biological support in association with a nonresorbable subcoracoid fixation can improve long-term stability in acromioclavicular joint dislocation surgically treated. We assessed clinical and radiographic results, patients' return to daily activities and the risk of complications. MATERIALS AND METHODS: Fourteen patients underwent subcoracoid fixation with the GraftRope system for chronic Rockwood type IV acromioclavicular joint dislocation. A total of 12 patients were evaluated clinically and radiologically with a minimum of 7 years of follow-up. RESULTS: Good reduction was obtained in all patients. All patients returned to work and sports at the pretrauma level with high mean scores on clinical evaluation. Regarding complications, 3 patients developed acromioclavicular arthritis. Ossifications were a common finding on x-rays, but they did not worsen the clinical outcome. CONCLUSIONS: The GraftRope surgical technique allows us to obtain an anatomical reduction of the acromio-clavicular joint, along with the restoration of the mechanical properties of the joint, owing to the use of a biological material with rigidity and load resistance features. Clinical results over the long term are encouraging. However, a 6-mm bone tunnel is too large since the average thickness of the coracoid process is only approximately 12 mm. This technique has some advantages over others: it avoids detachment of the deltoid, avoids the use of bulky metal implants with an important dissection of soft tissue, while it has all the advantages of an arthroscopic procedure.


Assuntos
Articulação Acromioclavicular/cirurgia , Artroplastia/métodos , Luxação do Ombro/cirurgia , Articulação Acromioclavicular/diagnóstico por imagem , Articulação Acromioclavicular/lesões , Articulação Acromioclavicular/fisiopatologia , Adulto , Artroscopia , Clavícula/lesões , Processo Coracoide/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Amplitude de Movimento Articular , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA