Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 149
Filtrar
1.
ACS Appl Mater Interfaces ; 13(37): 44302-44311, 2021 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-34499467

RESUMO

Dynamic ligand layers on nanoparticle surfaces could prove to be critically important to enhance the functionality of individual materials. Such capabilities could complement the properties of the inorganic component to provide multifunctionality or the ability to be remotely actuated. Peptide-based ligands have demonstrated the ability to be remotely responsive to structural changes when adsorbed to nanoparticle surfaces via incorporation of photoswitches into their molecular structure. In this contribution, direct spectroscopic evidence of the remote actuation of a photoswitchable peptide adsorbed onto Au nanoparticles is demonstrated using X-ray absorption fine structure spectroscopic methods. From this analysis, Au-X (X = C or N) coordination numbers confirm the changes before and after photoswitching in the surface ligand conformation, which was correlated directly to variations in the catalytic application of the materials for nitrophenol reduction processes. In addition, the catalytic application of the materials was demonstrated to be significantly sensitive to the structure of the nitrophenol substrate used in the reaction, suggesting that changes in the reactivity are likely based upon the peptide conformation and substrate structure. Such results confirm that surface ligands can be remotely reconfigured on nanoparticle surfaces, providing pathways to apply such capabilities to a variety of applications beyond catalysis ranging from drug delivery to sensing.


Assuntos
Proteínas Imobilizadas/química , Nanopartículas Metálicas/química , Peptídeos/química , Compostos Azo/química , Compostos Azo/efeitos da radiação , Catálise , Ouro/química , Proteínas Imobilizadas/efeitos da radiação , Ligantes , Maleimidas/química , Maleimidas/efeitos da radiação , Nanopartículas Metálicas/efeitos da radiação , Peptídeos/efeitos da radiação , Conformação Proteica/efeitos da radiação , Propriedades de Superfície/efeitos da radiação , Raios Ultravioleta
2.
J Mater Sci Mater Med ; 32(9): 108, 2021 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-34432156

RESUMO

Surface modification of superparamagnetic Fe3O4 nanoparticles using polymers (polyaniline/polypyrrole) was done by radio frequency (r.f.) plasma polymerization technique and characterized by XRD, TEM, TG/DTA and VSM. Surface-passivated Fe3O4 nanoparticles with polymers were having spherical/rod-shaped structures with superparamagnetic properties. Broad visible photoluminescence emission bands were observed at 445 and 580 nm for polyaniline-coated Fe3O4 and at 488 nm for polypyrrole-coated Fe3O4. These samples exhibit good fluorescence emissions with L929 cellular assay and were non-toxic. Magnetic hyperthermia response of Fe3O4 and polymer (polyaniline/polypyrrole)-coated Fe3O4 was evaluated and all the samples exhibit hyperthermia activity in the range of 42-45 °C. Specific loss power (SLP) values of polyaniline and polypyrrole-coated Fe3O4 nanoparticles (5 and 10 mg/ml) exhibit a controlled heat generation with an increase in the magnetic field.


Assuntos
Compostos de Anilina/química , Diagnóstico por Imagem/métodos , Hipertermia Induzida/métodos , Nanopartículas de Magnetita/química , Polímeros/química , Pirróis/química , Compostos de Anilina/efeitos da radiação , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Compostos Férricos/síntese química , Compostos Férricos/química , Compostos Férricos/efeitos da radiação , Humanos , Campos Magnéticos , Magnetismo/métodos , Nanopartículas de Magnetita/efeitos da radiação , Nanopartículas de Magnetita/uso terapêutico , Teste de Materiais , Gases em Plasma/química , Polímeros/efeitos da radiação , Pirróis/efeitos da radiação , Ondas de Rádio , Propriedades de Superfície/efeitos da radiação , Difração de Raios X
3.
PLoS One ; 16(3): e0247589, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33730103

RESUMO

Cold plasma generated in air at atmospheric pressure is an extremely effective antimicrobial agent, with proven efficacy against clinically relevant bacterial biofilms. The specific mode of bacterial inactivation is highly dependent upon the configuration of the plasma source used. In this study, the mode of microbial inactivation of a surface barrier discharge was investigated against Escherichia coli biofilms grown on polypropylene coupons. Different modes of exposure were considered and it was demonstrated that the long-lived reactive species created by the plasma are not solely responsible for the observed microbial inactivation. It was observed that a synergistic interaction occurs between the plasma generated long-lived reactive species and ultraviolet (UV) photons, acting to increase the antimicrobial efficacy of the approach by an order of magnitude. It is suggested that plasma generated UV is an important component for microbial inactivation when using a surface barrier discharge; however, it is not through the conventional pathway of direct DNA damage, rather through the synergistic interaction between liquid in the biofilm matrix and long-lived chemical species created by the discharge.


Assuntos
Antibacterianos/farmacologia , Biofilmes/efeitos dos fármacos , Biofilmes/efeitos da radiação , Escherichia coli/efeitos dos fármacos , Escherichia coli/efeitos da radiação , Viabilidade Microbiana/efeitos dos fármacos , Viabilidade Microbiana/efeitos da radiação , Fótons , Gases em Plasma/farmacologia , Raios Ultravioleta , Pressão Atmosférica , Escherichia coli/fisiologia , Polipropilenos/efeitos da radiação , Propriedades de Superfície/efeitos da radiação
4.
J Appl Oral Sci ; 28: e20190720, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32428059

RESUMO

Objective This study evaluated the clinical effect of violet LED light on in-office bleaching used alone or combined with 37% carbamide peroxide (CP) or 35% hydrogen peroxide (HP). Methodology A total of 100 patients were divided into five groups (n=20): LED, LED/CP, CP, LED/HP and HP. Colorimetric evaluation was performed using a spectrophotometer (ΔE, ΔL, Δa, Δb) and a visual shade guide (ΔSGU). Calcium (Ca)/phosphorous (P) ratio was quantified in the enamel microbiopsies. Measurements were performed at baseline (T 0 ), after bleaching (T B ) and in the 14-day follow-up (T 14 ). At each bleaching session, a visual scale determined the absolute risk (AR) and intensity of tooth sensitivity (TS). Data were evaluated by one-way (ΔE, Δa, ΔL, Δb), two-way repeated measures ANOVA (Ca/P ratio), and Tukey post-hoc tests. ΔSGU and TS were evaluated by Kruskal-Wallis and Mann-Whitney, and AR by Chi-Squared tests (a=5%). Results LED produced the lowest ΔE (p<0.05), but LED/HP promoted greater ΔE, ΔSGU and Δb (T 14 ) than HP (p<0.05). No differences were observed in ΔE and ΔSGU for LED/CP and HP groups (p>0.05). ΔL and Δa were not influenced by LED activation. After bleaching, LED/CP exhibited greater Δb than CP (p>0.05), but no differences were found between these groups at T 14 (p>0.05). LED treatment promoted the lowest risk of TS (16%), while HP promoted the highest (94.4%) (p<0.05). No statistical differences of risk of TS were found for CP (44%), LED/CP (61%) and LED/HP (88%) groups (p>0.05). No differences were found in enamel Ca/P ratio among treatments, regardless of evaluation times. Conclusions Violet LED alone produced the lowest bleaching effect, but enhanced HP bleaching results. Patients treated with LED/CP reached the same efficacy of HP, with reduced risk and intensity of tooth sensitivity and none of the bleaching protocols adversely affected enamel mineral content.


Assuntos
Peróxido de Carbamida/administração & dosagem , Peróxido de Hidrogênio/administração & dosagem , Luz , Fototerapia/métodos , Clareadores Dentários/administração & dosagem , Clareamento Dental/métodos , Adolescente , Adulto , Análise de Variância , Colorimetria , Terapia Combinada , Esmalte Dentário/efeitos dos fármacos , Esmalte Dentário/efeitos da radiação , Sensibilidade da Dentina/induzido quimicamente , Feminino , Humanos , Masculino , Valores de Referência , Fatores de Risco , Espectrofotometria , Estatísticas não Paramétricas , Propriedades de Superfície/efeitos dos fármacos , Propriedades de Superfície/efeitos da radiação , Resultado do Tratamento , Adulto Jovem
5.
Braz Oral Res ; 34: e005, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32022224

RESUMO

The purpose of this study was to evaluate the effect of ionizing radiation from high energy X-ray on fluoride release, surface roughness, flexural strength, and surface chemical composition of the materials. The study groups comprised five different restorative materials: Beautifil II, GCP Glass Fill, Amalgomer CR, Zirconomer, and Fuji IX GP. Twenty disk-shaped specimens (8x2 mm) for fluoride release and 20 bar-shaped specimens (25 x 2x 2 mm) for flexural strength were prepared from each material. Each material group was divided into two subgroups: irradiated (IR) and non-irradiated (Non-IR). The specimens from IR groups were irradiated with 1.8 Gy/day for 39 days (total IR = 70.2 Gy). The amount of fluoride released into deionized water was measured using a fluoride ion-selective electrode and ion analyzer after 24 hours and on days 2, 3, 7, 15, 21, 28, 35, and 39 (n = 10). The flexural strength was evaluated using the three-point bending test (n = 10). After the period of measurement of fluoride release, seven specimens (n = 7) from each group were randomly selected to evaluate surface roughness using AFM and one specimen was randomly selected for the SEM and EDS analyses. Data were analyzed with two-way ANOVA and Tukey tests (p = 0.05). The irradiation significantly increased fluoride release and surface roughness for Amalgomer CR and Zirconomer groups (p < 0.05). No significant change in flexural strength of the materials was observed after irradiation (p > 0.05). The ionizing radiation altered the amount of fluoride release and surface roughness of only Amalgomer CR and Zirconomer. The effect could be related to the chemical compositions of materials.


Assuntos
Apatitas/efeitos da radiação , Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Resinas Compostas/efeitos da radiação , Fluoretos/química , Cimentos de Ionômeros de Vidro/efeitos da radiação , Radiação Ionizante , Zircônio/efeitos da radiação , Análise de Variância , Apatitas/química , Bis-Fenol A-Glicidil Metacrilato/química , Resinas Compostas/química , Resistência à Flexão , Cimentos de Ionômeros de Vidro/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Valores de Referência , Reprodutibilidade dos Testes , Espectrometria por Raios X , Estatísticas não Paramétricas , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo , Zircônio/química
6.
Int J Mol Sci ; 21(3)2020 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-31979313

RESUMO

Titanium (Ti) is an osteoconductive material that is routinely used as a bulk implant to fix and restore bones and teeth. This study explored the effective use of Ti as a bone engineering scaffold. Challenges to overcome were: (1) difficult liquid/cell infiltration into Ti microfiber scaffolds due to the hydrophobic nature of Ti; and (2) difficult cell attachment on thin and curved Ti microfibers. A recent discovery of UV-photofunctionalization of Ti prompted us to examine its effect on Ti microfiber scaffolds. Scaffolds in disk form were made by weaving grade 4 pure Ti microfibers (125 µm diameter) and half of them were acid-etched to roughen the surface. Some of the scaffolds with original or acid-etched surfaces were further treated by UV light before cell culture. Ti microfiber scaffolds, regardless of the surface type, were hydrophobic and did not allow glycerol/water liquid to infiltrate, whereas, after UV treatment, the scaffolds became hydrophilic and immediately absorbed the liquid. Osteogenic cells from two different origins, derived from the femoral and mandibular bone marrow of rats, were cultured on the scaffolds. The number of cells attached to scaffolds during the early stage of culture within 24 h was 3-10 times greater when the scaffolds were treated with UV. The development of cytoplasmic projections and cytoskeletal, as well as the expression of focal adhesion protein, were exclusively observed on UV-treated scaffolds. Osteoblastic functional phenotypes, such as alkaline phosphatase activity and calcium mineralization, were 2-15 times greater on UV-treated scaffolds, with more pronounced enhancement on acid-etched scaffolds compared to that on the original scaffolds. These effects of UV treatment were associated with a significant reduction in atomic carbon on the Ti microfiber surfaces. In conclusion, UV treatment of Ti microfiber scaffolds tunes their physicochemical properties and effectively enhances the attachment and function of osteoblasts, proposing a new strategy for bone engineering.


Assuntos
Osseointegração , Osteoblastos/metabolismo , Alicerces Teciduais/química , Titânio/efeitos da radiação , Animais , Células da Medula Óssea/citologia , Calcificação Fisiológica/fisiologia , Técnicas de Cultura de Células , Células Cultivadas , Fêmur/citologia , Interações Hidrofóbicas e Hidrofílicas , Masculino , Mandíbula/citologia , Microscopia Eletrônica de Varredura , Osteoblastos/química , Osteoblastos/enzimologia , Osteogênese/fisiologia , Ratos , Ratos Sprague-Dawley , Propriedades de Superfície/efeitos da radiação , Engenharia Tecidual , Titânio/química , Raios Ultravioleta
7.
Braz. oral res. (Online) ; 34: e005, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1055521

RESUMO

Abstract The purpose of this study was to evaluate the effect of ionizing radiation from high energy X-ray on fluoride release, surface roughness, flexural strength, and surface chemical composition of the materials. The study groups comprised five different restorative materials: Beautifil II, GCP Glass Fill, Amalgomer CR, Zirconomer, and Fuji IX GP. Twenty disk-shaped specimens (8x2 mm) for fluoride release and 20 bar-shaped specimens (25 x 2x 2 mm) for flexural strength were prepared from each material. Each material group was divided into two subgroups: irradiated (IR) and non-irradiated (Non-IR). The specimens from IR groups were irradiated with 1.8 Gy/day for 39 days (total IR = 70.2 Gy). The amount of fluoride released into deionized water was measured using a fluoride ion-selective electrode and ion analyzer after 24 hours and on days 2, 3, 7, 15, 21, 28, 35, and 39 (n = 10). The flexural strength was evaluated using the three-point bending test (n = 10). After the period of measurement of fluoride release, seven specimens (n = 7) from each group were randomly selected to evaluate surface roughness using AFM and one specimen was randomly selected for the SEM and EDS analyses. Data were analyzed with two-way ANOVA and Tukey tests (p = 0.05). The irradiation significantly increased fluoride release and surface roughness for Amalgomer CR and Zirconomer groups (p < 0.05). No significant change in flexural strength of the materials was observed after irradiation (p > 0.05). The ionizing radiation altered the amount of fluoride release and surface roughness of only Amalgomer CR and Zirconomer. The effect could be related to the chemical compositions of materials.


Assuntos
Apatitas/efeitos da radiação , Radiação Ionizante , Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Resinas Compostas/efeitos da radiação , Fluoretos/química , Cimentos de Ionômeros de Vidro/efeitos da radiação , Apatitas/química , Valores de Referência , Espectrometria por Raios X , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo , Zircônio/efeitos da radiação , Zircônio/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Análise de Variância , Bis-Fenol A-Glicidil Metacrilato/química , Estatísticas não Paramétricas , Resinas Compostas/química , Resistência à Flexão , Cimentos de Ionômeros de Vidro/química
8.
J. appl. oral sci ; 28: e20190720, 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1134776

RESUMO

Abstract Objective This study evaluated the clinical effect of violet LED light on in-office bleaching used alone or combined with 37% carbamide peroxide (CP) or 35% hydrogen peroxide (HP). Methodology A total of 100 patients were divided into five groups (n=20): LED, LED/CP, CP, LED/HP and HP. Colorimetric evaluation was performed using a spectrophotometer (ΔE, ΔL, Δa, Δb) and a visual shade guide (ΔSGU). Calcium (Ca)/phosphorous (P) ratio was quantified in the enamel microbiopsies. Measurements were performed at baseline (T 0 ), after bleaching (T B ) and in the 14-day follow-up (T 14 ). At each bleaching session, a visual scale determined the absolute risk (AR) and intensity of tooth sensitivity (TS). Data were evaluated by one-way (ΔE, Δa, ΔL, Δb), two-way repeated measures ANOVA (Ca/P ratio), and Tukey post-hoc tests. ΔSGU and TS were evaluated by Kruskal-Wallis and Mann-Whitney, and AR by Chi-Squared tests (a=5%). Results LED produced the lowest ΔE (p<0.05), but LED/HP promoted greater ΔE, ΔSGU and Δb (T 14 ) than HP (p<0.05). No differences were observed in ΔE and ΔSGU for LED/CP and HP groups (p>0.05). ΔL and Δa were not influenced by LED activation. After bleaching, LED/CP exhibited greater Δb than CP (p>0.05), but no differences were found between these groups at T 14 (p>0.05). LED treatment promoted the lowest risk of TS (16%), while HP promoted the highest (94.4%) (p<0.05). No statistical differences of risk of TS were found for CP (44%), LED/CP (61%) and LED/HP (88%) groups (p>0.05). No differences were found in enamel Ca/P ratio among treatments, regardless of evaluation times. Conclusions Violet LED alone produced the lowest bleaching effect, but enhanced HP bleaching results. Patients treated with LED/CP reached the same efficacy of HP, with reduced risk and intensity of tooth sensitivity and none of the bleaching protocols adversely affected enamel mineral content.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Fototerapia/métodos , Clareamento Dental/métodos , Clareadores Dentários/administração & dosagem , Peróxido de Carbamida/administração & dosagem , Peróxido de Hidrogênio/administração & dosagem , Luz , Valores de Referência , Espectrofotometria , Propriedades de Superfície/efeitos dos fármacos , Propriedades de Superfície/efeitos da radiação , Fatores de Risco , Análise de Variância , Resultado do Tratamento , Colorimetria , Terapia Combinada , Estatísticas não Paramétricas , Esmalte Dentário/efeitos dos fármacos , Esmalte Dentário/efeitos da radiação , Sensibilidade da Dentina/induzido quimicamente
9.
J. appl. oral sci ; 28: e20190693, 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1134791

RESUMO

Abstract Debonding, staining and wear are usually the reasons for denture teeth replacement by new ones from same or different brands. Objective This study investigates the possible differences in color of denture teeth of the same or different brands under different illuminations, since their metameric behavior in color under specific illumination may become unacceptable. Methodology For the purpose of this study, 10 denture teeth (#11), shade A3, of 4 different brands were selected (Creopal/KlemaDental Pro, Executive/DeguDent, Cosmo HXL/DeguDent, Ivostar/Ivoclar-Vivadent). Teeth stabilized in white silicone mold and the CIELAB color coordinates of their labial surface under 3 different illumination lights (D65, F2, A) were recorded, using a portable colorimeter (FRU/WR-18, Wave Inc). ΔE*ab values of all possible pairs of teeth of the same brand (n=45) or pair combinations of different brands (n=100) under each illumination light, in a dry and wet state were calculated. Data were analyzed statistically using 3-way ANOVA, Friedman's and Wilcoxon's tests at a significance level of α=0.05. Results The results showed that brand type affected significantly L*, a* and b* coordinates (p<0.0001), illumination a* and b* coordinates (p<0.0001), but none of them was affected by the hydration state of teeth (p>0.05). Intra-brand color differences ranged between 0.21-0.78ΔΕ* units with significant differences among brands (p<0.0001), among illumination lights (p<0.0001) and between hydration states (p=0.0001). Inter-brand differences ranged between 2.29-6.29ΔΕ* units with significant differences among pairs of brands (p<0.0001), illumination lights (p<0.0001) and hydration states (p<0.0001). Conclusions Differences were found between and within brands under D65 illumination which increased under F2 or A illumination affected by brand type and hydration status. Executive was the most stable brand than the others under different illuminations or wet states and for this reason its difference from other brands is the lowest. In clinical practice, there should be no blending of teeth of different brands but if we must, we should select those that are more stable under different illuminations


Assuntos
Humanos , Iluminação , Dentaduras , Pigmentação em Prótese , Valores de Referência , Propriedades de Superfície/efeitos da radiação , Teste de Materiais , Análise de Variância , Colorimetria , Estatísticas não Paramétricas
10.
PLoS One ; 14(7): e0219198, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31291308

RESUMO

The light-promoted recovery of epidermal barrier of skin was evaluated by the associated recovery of transepidermal potential (TEP), the potential difference between the surface and dermis of skin, by using porcine skin samples. An accelerated recovery of TEP was observed by irradiation of red light with the irradiance of 40 mW/cm2 and a duration of > 10 min. The influence of the light stimulation to the surroundings (~ 20 mm) was also observed. The irradiations of blue and purple lights were ineffective in accelerating the barrier recovery. These characteristics of the light stimulation would be useful for the design of effective and safe phototherapy devices for skin. The present study proves that the TEP can serve as a spatiotemporal indicator of the epidermal barrier function.


Assuntos
Derme/efeitos da radiação , Epiderme/efeitos da radiação , Fototerapia , Pele/efeitos da radiação , Acetona/metabolismo , Animais , Humanos , Luz , Sais/metabolismo , Propriedades de Superfície/efeitos da radiação , Suínos
11.
Lasers Surg Med ; 51(9): 797-807, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31168853

RESUMO

BACKGROUND AND OBJECTIVES: The employability of the non-invasive femtosecond laser ablation technique for dental treatment has been severely limited by its low ablation rate despite the advantage of minimal tissue damage. The study explores a means of improving the femtosecond laser ablation rate and efficiency by physiochemical surface modification. MATERIALS AND METHODS: Surface modification of dental hard tissues has been carried out by food graded orthophosphoric acid and Carie care gel pretreatment. The laser ablation characteristics were studied by using a Ti:Sapphire laser (10 kHz, 10 mm/s, 100 fs, 800 nm) to ascertain the influence of pretreatment. Surface morphology and chemical composition were obtained by using an optical profiler, SEM and EDAX. RESULTS: The ablation threshold fluence decreased by almost one-third whereas the ablation rate and ablation efficiency nearly tripled upon pretreatment. The microstructural and compositional analysis clearly reveals that surface modification and demineralization reduce the threshold fluence and increase the ablation rate by effective utilization of the laser beam energy. The pretreatment effect is more pronounced in orthophosphoric acid as compared with Carie care gel. CONCLUSIONS: Physiochemical surface modification can be an efficient method to improve the laser ablation rate and ablation efficiency. Compositional analysis can be an elegant tool for pre-surgery determination of laser ablation characteristics. CLINICAL SIGNIFICANCES: Pretreatment surface modification can be an effective way to overcome the limitation of the femtosecond laser for tooth preparation in the clinical setting by strongly enhancing the ablation rate. An enhanced ablation rate along with de nova prediction of ablation characteristics will enable the clinician to perform dental surgery in real time with minimal tissue damage. Lasers Surg. Med. © 2019 Wiley Periodicals, Inc.


Assuntos
Corrosão Dentária/métodos , Terapia a Laser , Dente/efeitos da radiação , Adolescente , Adulto , Humanos , Terapia a Laser/métodos , Microscopia Eletrônica , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo , Dente/anatomia & histologia , Adulto Jovem
12.
Arch Oral Biol ; 98: 195-203, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30502562

RESUMO

OBJECTIVE: To investigate effects of HIFU on macrophage phenotype, surface micro-topography and nano-scale surface mechanical properties of dental cementum. MATERIALS AND METHODS: Root discs (2 mm thickness) were cut apical to CEJ and sectioned into quadrants. HIFU setup with bowl-shaped piezo ceramic transducer submerged in a water tank was used for exposure on each specimen for 15 s, 30 s or 60 s. The specimens of the control group were left without any HIFU exposure. HIFU was generated with a continuous sinusoidal wave of 120Vpp amplitude, 250 KHZ resonance-frequency and highest ultrasonic pressure of ∼10 bar at the focus. Specimens for SEM were viewed, and micro-topography characterization performed, using AFM and Ra parameter and surface area (SA) calculated by specialized SPM surface analysis software. For nano-indentation testing, experiments were carried out using AFM. Macrophage cell isolation and culturing was performed on cementum to receive the HIFU treatment at different time periods. Raman spectroscopy were scanned to create spectra perpendicular to the cementum substrate to analyze generation of standard spectra for Raman intensity ratio of hydroxyapatite normalized to the peaks ν1 960 cm-1. Data was expressed as means ± standard deviations and analyzed by one-way ANOVA in term of Ra, SA, H and Er. Different points for fluorescence intensity ratio were analyzed by Raman using Wilcoxon rank sum test. RESULTS: HIFU exposure at 60 s removed the smear layer and most of cementum appeared smoothened. AFM characterisation, showed a slight decrease in the irregularity of the surface as exposure time increased. Intact macrophages can be identified in control and all experimental HIFU groups. The level of fluorescence for the control and HIFU 15 and 30 s were low as compared to HIFU 60 s. CONCLUSION: If HIFU can be successfully implemented, it may be a possible alternative to current methods used in periodontal therapy to achieve smooth root surfaces.


Assuntos
Cemento Dentário/metabolismo , Cemento Dentário/efeitos da radiação , Tratamento por Ondas de Choque Extracorpóreas/métodos , Macrófagos/metabolismo , Macrófagos/efeitos da radiação , Análise de Variância , Cemento Dentário/ultraestrutura , Relação Dose-Resposta à Radiação , Durapatita , Fluorescência , Doenças Periodontais/radioterapia , Doses de Radiação , Análise Espectral Raman , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo , Raiz Dentária/efeitos da radiação , Raiz Dentária/ultraestrutura , Transdutores
13.
J. appl. oral sci ; 27: e20180126, 2019. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-975877

RESUMO

Abstract Objectives: The aim of this in vitro study was to evaluate the bonding strength of non-simplified dentin bonding systems (DBS) to dentin irradiated with a diode laser (970 nm) immediately and after 12 months of water storage following either primer or bond application. Material and methods: The experimental design included three different factors: DBS type [AdperTM Scotchbond Multipurpose (MP) and Clearfil™ SE Bond (CSE)], irradiation [without irradiation - control (C), irradiation after primer application (AP), and irradiation after bond application (AB)], and time [initial (I) and after 12 months of water storage (12 m)]. Sixty sound human third molars (n = 10) were obtained, and their flat occlusal dentin areas were prepared and standardized. Laser irradiation was performed in the contact mode perpendicular to the dental surface over an automatically selected scanning area at a pulse energy of 0.8 W, frequency of 10 Hz, and energy density of 66.67 J/cm2. After 7 days of treatment, the specimens were cut, and half of them were subjected to microtensile testing (500 N/0.05 mm/min), whereas the remaining sticks were examined after 12 months of water storage. The obtained data were analyzed by three-way analysis of variance (ANOVA) followed by a Tukey test (p<0.05). The observed fracture modes were investigated using a portable digital microscope with a magnification of 40x. Results: Among the utilized DBS, MP generally exhibited higher bond strengths, but did not always differ from CSE under similar conditions. The irradiation factor was statistically significant only for the MP/AB groups. After 12 months of storage, all groups demonstrated a significant reduction in the bond strength, whereas the results of fracture analysis showed a predominance of the adhesive type. Conclusions: The laser treatment of non-simplified DBS was not able to stabilize their bonding characteristics after 12 months.


Assuntos
Humanos , Colagem Dentária/métodos , Adesivos Dentinários/efeitos da radiação , Cimentos de Resina/efeitos da radiação , Dentina/efeitos da radiação , Lasers Semicondutores , Valores de Referência , Propriedades de Superfície/efeitos da radiação , Resistência à Tração , Fatores de Tempo , Teste de Materiais , Água/química , Reprodutibilidade dos Testes , Análise de Variância , Adesivos Dentinários/química , Microscopia de Força Atômica , Cimentos de Resina/química , Dentina/efeitos dos fármacos , Polimerização/efeitos da radiação
14.
J. appl. oral sci ; 27: e20180075, 2019. graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-975874

RESUMO

Abstract Currently, there is no consensus in terms of defining the minimum radiant exposure values necessary for achieving adequate properties of composite resin. In addition, the long-term influence that radiant exposure has on the properties of composite resins is still questionable. Objective: The objective of this study was to evaluate the effect of radiant exposure and UV accelerated aging on the physico-chemical and mechanical properties of micro-hybrid and nanofilled composite resins. Material and Methods: A nanofilled (Filtek Supreme; 3M ESPE) and a micro-hybrid composite resin (Filtek Z250; 3M ESPE) were investigated under different radiant exposures (3.75, 9, and 24 J/cm2) and UV accelerated aging protocols (0, 500, 1000, and 1500 aging hours). The degree of conversion (DC), flexural strength (FS), modulus (M), water sorption (WS), and solubility (WL) were evaluated. The results obtained were analyzed using two-way ANOVA and Tukey's test. Comparisons were performed using a significance level of α=0.05. Results: The DC, FS, and M were found to be significantly influenced by both radiant exposure and accelerated aging time. The DC and EM increased with radiant exposure in the no-aging group (0-hour aging) for both micro-hybrid and nanofilled composites, whereas no correlation was found after accelerated aging protocols. WS and WL of micro-hybrid and nanofilled composite resins were scarcely affected by radiant exposure (p>0.05), whereas they were significantly reduced by accelerated aging (p<0.001). Conclusions: Although increasing radiant exposure affected the degree of conversion and mechanical properties of micro-hybrid and nanofilled composites, no influence on the hydrolytic degradation of the material was observed. In contrast, UV accelerated aging affected both the physico-chemical and mechanical properties of the composites.


Assuntos
Raios Ultravioleta , Resinas Compostas/efeitos da radiação , Resinas Compostas/química , Doses de Radiação , Valores de Referência , Solubilidade , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo , Teste de Materiais , Água/química , Microscopia Eletrônica de Varredura , Análise de Variância , Espectroscopia de Infravermelho com Transformada de Fourier , Transição de Fase/efeitos da radiação , Lâmpadas de Polimerização Dentária , Processos Fotoquímicos/efeitos da radiação , Polimerização/efeitos dos fármacos , Resistência à Flexão/efeitos da radiação
15.
Braz Oral Res ; 32: e121, 2018 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-30517430

RESUMO

The aim of this study was to evaluate the influence of radiation therapy on root canal sealer push-out bond strength (BS) to dentin and the sealer/dentin interface after different final irrigation solutions (NaOCl, EDTA, and chitosan). Sixty-four maxillary canines were distributed into two groups (n=30): non-irradiated and irradiated with 60 Gy. Canals were prepared with Reciproc-R50 and subdivided (n=10) for final irrigation (NaOCl, EDTA, chitosan) and filled. Three dentin slices were obtained from each root third. The first slice of each third was selected for BS evaluation, and the failure mode was determined by stereomicroscopy. SEM analysis of the sealer-dentin interface was performed in the remaining slices. Two-way ANOVA and Tukey's tests (α=0.05) were used. Lower BS (P<0.0001) was obtained after irradiation (2.07±0.79 MPa), regardless of the final irrigation solution used. The NaOCl group (P<0.001) had the lowest BS in the irradiated (1.68±0.72) and non-irradiated (2.39±0.89) groups, whereas the EDTA (irradiated: 2.14±0.77 and non-irradiated: 3.92±1.54) and chitosan (irradiated: 2.37±0.73 and non-irradiated: 3.51±1.47) groups demonstrated a higher BS (P<0.05). The highest values were observed in the coronal third (3.17±1.38) when compared to the middle (2.74±1.36) and apical ones (2.09±0.97)(P<0.0001). There were more cohesive failures and more gaps in irradiated specimens, regardless of the final solution. The present study showed that radiation was associated with a decrease in BS, regardless of the final solution used, whereas chitosan increased BS in teeth subjected to radiation therapy.


Assuntos
Colagem Dentária/métodos , Dentina/efeitos dos fármacos , Dentina/efeitos da radiação , Resinas Epóxi/efeitos da radiação , Materiais Restauradores do Canal Radicular/efeitos da radiação , Irrigantes do Canal Radicular/efeitos da radiação , Análise de Variância , Quitosana/química , Falha de Restauração Dentária , Ácido Edético/química , Resinas Epóxi/química , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Materiais Restauradores do Canal Radicular/química , Irrigantes do Canal Radicular/química , Hipoclorito de Sódio/química , Estatísticas não Paramétricas , Propriedades de Superfície/efeitos dos fármacos , Propriedades de Superfície/efeitos da radiação , Raiz Dentária/efeitos dos fármacos , Raiz Dentária/efeitos da radiação
16.
An. acad. bras. ciênc ; 90(1): 195-204, Mar. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-886907

RESUMO

ABSTRACT Demand for medical implants is rising day by day as the world becomes the place for more diseased and older people. Accordingly, in this research, metallocene polyethylene (mPE), a commonly used polymer was treated with UV rays for improving its biocompatibility. Scanning electron microscopy (SEM) images confirmed the formation of crests and troughs, which depicts the improvement of surface roughness of mPE substrates caused by UV etching. Accordingly, the contact angle measurements revealed that the wettability of mPE-2.5 J/cm2 (68.09º) and mPE-5 J/cm2 (57.93º) samples were found to be increased compared to untreated mPE (86.84º) indicating better hydrophilicity. Further, the UV treated surface exhibited enhanced blood compatibility as determined in APTT (untreated mPE- 55.3 ± 2.5 s, mPE-2.5 J/cm2 - 76.7 ± 4.1 s and mPE-5 J/cm2 - 112.3 ± 2 s) and PT (untreated mPE - 24.7 ± 1.5 s, mPE- 2.5 J/cm2 - 34.3 ± 1.1 s and mPE-5 J/cm2 - 43 ± 2 s) assay. Moreover, the treated mPE-2.5 J/cm2 (4.88%) and mPE-5 J/cm2 (1.79%) showed decreased hemolytic percentage compared to untreated mPE (15.40%) indicating better safety to red blood cells. Interestingly, the changes in physicochemical properties of mPE are directly proportional to the dosage of the UV rays. UV modified mPE surfaces were found to be more compatible as identified through MTT assay, photomicrograph and SEM images of the seeded 3T3 cell population. Hence UV-modified surface of mPE may be successfully exploited for medical implants.


Assuntos
Animais , Coelhos , Ratos , Raios Ultravioleta , Teste de Materiais , Metalocenos/efeitos da radiação , Propriedades de Superfície/efeitos da radiação , Bovinos , Microscopia Eletrônica de Varredura , Células 3T3 , Interações Hidrofóbicas e Hidrofílicas , Metalocenos/química , Hemólise , Histocompatibilidade
17.
Photomed Laser Surg ; 36(2): 72-77, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29028438

RESUMO

OBJECTIVE: The aim of this review was to evaluate the balling phenomenon which occurs typically in Selective Laser Sintering (SLS). BACKGROUND DATA: The balling phenomenon is a typical SLS defect, and observed in laser sintered powder, significantly reduces the quality of SLS, and hinders the further development of SLS Technology. METHODS: Electronic database searches were performed using Google Scholar. The keywords "laser sintering, selective laser sintering, direct metal laser melting, and balling phenomenon" were searched in title/abstract of publications, limited to December 31, 2016. The inclusion criteria were SLS, balling phenomenon, some alloys (such as Cr-Co, iron, stainless steel, and Cu-based alloys) mechanical properties, microstructure and bond strength between metal-ceramic crown, laboratory studies, full text, and in English language. RESULTS: A total of 100 articles were found the initial search and yielded a total of 50 studies, 30 of which did not fulfill the inclusion criteria and were therefore excluded. In addition, 20 studies were found by screening the reference list of all included publications. Finally, 40 studies were selected for this review. CONCLUSIONS: The method in question is regulated by powder material characteristics and the conditions of laser processing. The procedure of formation, affecting factors, and the mechanism of the balling effect are very complex.


Assuntos
Ligas de Cromo/química , Colagem Dentária/instrumentação , Lasers , Terapia com Luz de Baixa Intensidade/métodos , Ligas Metalo-Cerâmicas/química , Técnica de Fundição Odontológica , Desenho de Equipamento , Humanos , Terapia com Luz de Baixa Intensidade/efeitos adversos , Teste de Materiais , Controle de Qualidade , Estresse Mecânico , Propriedades de Superfície/efeitos da radiação
18.
J. appl. oral sci ; 26: e20160662, 2018. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893738

RESUMO

ABSTRACT Objective: The main goal of this study was to compare the polymerization degree of bulk-fill giomer resin cured with three different light-curing units (LCUs): a polywave third-generation (Valo); a monowave (DemiUltra: DU); and a second-generation LED (Optima 10: Opt) LCUs by using structural and mechanical properties. Material and methods: Giomer samples of 2 and 4 mm cured with three LCUs were employed in vitro analysis. The degree of curing (DC%) was determined with Fourier-Transform Infrared Spectroscopy (FTIR). Microstructural features were observed with scanning electron microscopy (SEM). Flexural strength (FS), compression strength (CS), elastic modulus and fracturing strain were determined for mechanical properties. Surface microhardness (SMH) values were also measured. Oneway ANOVA, two-way analysis of variance and Tukey multiple comparison tests were used for statistically analyzing the FS and SMH. Results: DC% values were 58.2, 47.6, and 39.7 for the 2 mm samples cured with DU, Opt., and Valo LCUs, respectively. DC% values of the 4 mm samples were 50.4, 44.6, and 38.2 for DU, Opt, and Valo, respectively. SMH values were Valo, Opt<DU at top of the samples; Valo<DU, Opt at 2 mm, and DU, Valo<Opt at 4 mm depth. Giomer samples cured with Opt and DU exhibited higher FS values than Valo. CS values were similar but compressive modulus and fracturing strain (%) varied depending on the curing protocol. Conclusions: Based on the results, it can be concluded that curing device and protocol strongly affect crosslinking reactions and thus DC%, SMH, compressive modulus and strain at break values. Consequently, it can be deduced that curing protocol is possibly the most important parameter for microstructure formation of highly-filled composite restoratives because it may bring some structural defects and physical frailties on restorations due to lower degree of polymerization.


Assuntos
Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Bis-Fenol A-Glicidil Metacrilato/química , Resinas Compostas/efeitos da radiação , Resinas Compostas/química , Cura Luminosa de Adesivos Dentários/métodos , Polimerização/efeitos da radiação , Valores de Referência , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Análise de Variância , Espectroscopia de Infravermelho com Transformada de Fourier , Estatísticas não Paramétricas , Força Compressiva , Módulo de Elasticidade , Testes de Dureza
19.
Braz. oral res. (Online) ; 32: e121, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-974461

RESUMO

Abstract The aim of this study was to evaluate the influence of radiation therapy on root canal sealer push-out bond strength (BS) to dentin and the sealer/dentin interface after different final irrigation solutions (NaOCl, EDTA, and chitosan). Sixty-four maxillary canines were distributed into two groups (n=30): non-irradiated and irradiated with 60 Gy. Canals were prepared with Reciproc-R50 and subdivided (n=10) for final irrigation (NaOCl, EDTA, chitosan) and filled. Three dentin slices were obtained from each root third. The first slice of each third was selected for BS evaluation, and the failure mode was determined by stereomicroscopy. SEM analysis of the sealer-dentin interface was performed in the remaining slices. Two-way ANOVA and Tukey's tests (α=0.05) were used. Lower BS (P<0.0001) was obtained after irradiation (2.07±0.79 MPa), regardless of the final irrigation solution used. The NaOCl group (P<0.001) had the lowest BS in the irradiated (1.68±0.72) and non-irradiated (2.39±0.89) groups, whereas the EDTA (irradiated: 2.14±0.77 and non-irradiated: 3.92±1.54) and chitosan (irradiated: 2.37±0.73 and non-irradiated: 3.51±1.47) groups demonstrated a higher BS (P<0.05). The highest values were observed in the coronal third (3.17±1.38) when compared to the middle (2.74±1.36) and apical ones (2.09±0.97)(P<0.0001). There were more cohesive failures and more gaps in irradiated specimens, regardless of the final solution. The present study showed that radiation was associated with a decrease in BS, regardless of the final solution used, whereas chitosan increased BS in teeth subjected to radiation therapy.


Assuntos
Humanos , Materiais Restauradores do Canal Radicular/efeitos da radiação , Irrigantes do Canal Radicular/efeitos da radiação , Colagem Dentária/métodos , Dentina/efeitos dos fármacos , Dentina/efeitos da radiação , Resinas Epóxi/efeitos da radiação , Materiais Restauradores do Canal Radicular/química , Irrigantes do Canal Radicular/química , Hipoclorito de Sódio/química , Propriedades de Superfície/efeitos dos fármacos , Propriedades de Superfície/efeitos da radiação , Raiz Dentária/efeitos dos fármacos , Raiz Dentária/efeitos da radiação , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Análise de Variância , Ácido Edético/química , Estatísticas não Paramétricas , Falha de Restauração Dentária , Quitosana/química , Resinas Epóxi/química , Neoplasias de Cabeça e Pescoço/radioterapia
20.
Braz. oral res. (Online) ; 32: e122, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-974460

RESUMO

Abstract: The effects of tooth brushing could affect the long-term esthetic outcome of composite restorations. This study evaluated the effect of two different emission spectrum light-curing units on the surface roughness, roughness profile, topography and microhardness of bulk-fill composites after in vitro toothbrushing. Valo (multiple-peak) and Demi Ultra (single-peak) curing lights were each used for 10s to polymerize three bulk-fill resin composites: Filtek Bulk Fill Posterior Restorative (FBF), Tetric EvoCeram Bulk Fill (TET) and Surefil SDR Flow (SDR). After 30,000 reciprocal strokes in a toothbrushing machine, the roughness profile, surface roughness, surface morphology, and microhardness were examined. Representative SEM images were also obtained. When light-cured with the Demi Ultra, SDR showed the most loss in volume compared to the other composites and higher volume loss compared to when was light-cured with Valo. The highest surface roughness and roughness profile values were found in SDR after toothbrushing, for both light-curing units tested. FBF always had the greatest microhardness values. Light-curing TET with Valo resulted in higher microhardness compared to when using the Demi Ultra. Confocal and SEM images show that toothbrushing resulted in smoother surfaces for FBF and TET. All composites exhibited surface volume loss after toothbrushing. The loss in volume of SDR depended on the light-curing unit used. Toothbrushing can alter the surface roughness and superficial aspect of some bulk-fill composites. The choice of light-curing unit did not affect the roughness profile, but, depending on the composite, it affected the microhardness.


Assuntos
Escovação Dentária/efeitos adversos , Resinas Compostas/efeitos da radiação , Lâmpadas de Polimerização Dentária , Propriedades de Superfície/efeitos dos fármacos , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Análise de Variância , Microscopia Confocal , Resinas Compostas/química , Cura Luminosa de Adesivos Dentários/métodos , Polimerização , Dureza/efeitos dos fármacos , Dureza/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA