Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 205
Filtrar
1.
PLoS One ; 16(7): e0253807, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34242264

RESUMO

Determining values of plasma renin activity (PRA) or plasma active renin concentration (ARC), plasma aldosterone concentration (PAC), and aldosterone-to-renin ratio (ARR) is essential to diagnose primary aldosteronism (PA), but it takes several days with conventional radioimmunoassays (RIAs). Chemiluminescent enzyme immunoassays for PAC and ARC using the Accuraseed® immunoanalyzer facilitated the determination, but relations between Accuraseed® immunoanalyzer-based and RIA-based values in samples of PA confirmatory tests and adrenal venous sampling remained to be elucidated. We addressed this issue in the present study. This is a prospective, cross-sectional study. ARC and PAC values were measured by the Accuraseed® immunoanalyzer in samples, in which PRA and PAC values had been measured by the PRA-FR® RIA and SPAC®-S Aldosterone kits, respectively. The relations between Accuraseed® immunoanalyzer-based and RIA-based values were investigated with regression analyses. The optimal cutoff of Accuraseed® immunoanalyzer-based ARR for PA screening was determined by the receiver operating characteristic analysis. After log-log transformations, linear relations with high coefficients of determination were observed between Accuraseed® immunoanalyzer-based and RIA-based data of renin and aldosterone. Following the PA guidelines of Japan Endocrine Society, Accuraseed® immunoanalyzer-based cutoffs were calculated from the regression equations: the basal PAC for PA screening >12 ng/dL, PAC for the saline infusion test >8.2 ng/dL, ARC for the furosemide-upright test <15 pg/mL, and ARR for the captopril challenge test >3.09 ng/dL per pg/mL. The optimal cutoff of Accuraseed® immunoanalyzer-based ARR for PA screening was >2.43 ng/dL over pg/mL not to overlook bilateral PA patients. The present study provided conversion formulas between Accuraseed® immunoanalyzer-based and RIA-based values of renin, aldosterone, and ARR, not only in basal samples but also in samples of PA confirmatory tests and adrenal venous sampling. Although validation studies are awaited, the present study will become priming water of harmonization of renin and aldosterone immunoassays.


Assuntos
Aldosterona/sangue , Hiperaldosteronismo/diagnóstico , Programas de Rastreamento/instrumentação , Renina/sangue , Adulto , Idoso , Estudos Transversais , Feminino , Humanos , Hiperaldosteronismo/sangue , Japão , Medições Luminescentes/instrumentação , Medições Luminescentes/normas , Medições Luminescentes/estatística & dados numéricos , Masculino , Programas de Rastreamento/métodos , Programas de Rastreamento/normas , Programas de Rastreamento/estatística & dados numéricos , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Radioimunoensaio/instrumentação , Radioimunoensaio/normas , Radioimunoensaio/estatística & dados numéricos , Valores de Referência
2.
Scand J Clin Lab Invest ; 80(5): 427-432, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32478619

RESUMO

In the context of point of care testing (PoCT) and ISO 22870, internal quality control (IQC) is a crucial part of PoCT accreditation processes. Quality Control materials shall be periodically examined with a frequency that is based on the robustness of the analytical procedure and the risk of harm to the patient from an erroneous result. We propose to apply the statistical quality control (SQC) procedure to develop an individualized QC plan for AQT90 flex instrument used in PoCT. The robustness is determined by the sigma-metric and analytical goal represented by an allowable total error (TEa) is evaluated using a Varela graphic tool. A Sigma-metric SQC run size nomogram for estimating the number of patient samples between IQC events. According to the calculated robustness we can distinguish 3 groups of parameters: HCG and CRP with large sample size per event, D-Dimer and Procalcitonin with an average sample size per event and Myoglobin. NT-proBNP. and Troponin T with a limited sample size per event. In PoCT, the SQC strategy can promote more effective, and not necessarily more frequent, IQC.


Assuntos
Automação Laboratorial/normas , Testes Imediatos/normas , Radioimunoensaio/normas , Proteína C-Reativa/metabolismo , Gonadotropina Coriônica/sangue , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Humanos , Mioglobina/sangue , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Pró-Calcitonina/sangue , Controle de Qualidade , Troponina T/sangue
3.
Endocr J ; 67(7): 759-770, 2020 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-32269183

RESUMO

Calcitonin (CT) is a marker for both initial diagnosis and monitoring of patients with residual or recurrent medullary thyroid carcinoma (MTC). In Japan, serum CT had been measured by radioimmunoassay (RIA) until recently. Electrochemiluminescence immunoassay (ECLIA) became commercially available in 2014, and this technique is now the only method used to examine CT concentration. The purposes of this study were to investigate the correlations between the CT concentration measured with ECLIA (ECLIA-CT) and RIA (RIA-CT) and to explore the clinical characteristics of patients with elevated ECLIA-CT. CT concentrations of 348 sera samples from 334 patients with various thyroid disorders including nine MTC were measured using both assays. The correlation analysis revealed an excellent correlation between ECLIA-CT and RIA-CT among the cases with CT level >150 pg/mL by both assays (rs = 0.991, p < 0.001). However, 63% of all samples exhibited undetectable ECLIA-CT, while their RIA-CTs were measured between 15 and 152 pg/mL. The ECLIA-CTs in all patients who underwent total thyroidectomy for non-MTC showed low concentrations. High ECLIA-CT was observed in patients with MTC or pancreas neuroendocrine tumor. ECLIA-CT was also increased in 14 other male patients with non-MTC, including four with renal failure. Multivariate logistic regression analysis showed that male sex, negative TgAb, and lower estimated glomerular filtration rate were independent factors to predict detectable ECLIA-CT (≥0.500 pg/mL). These results indicate that ECLIA-CT correlates well with RIA-CT in higher range and is affected by sex, TgAb, and renal function.


Assuntos
Autoanticorpos/sangue , Calcitonina/análise , Carcinoma Neuroendócrino/diagnóstico , Nefropatias/sangue , Medições Luminescentes/métodos , Neoplasias da Glândula Tireoide/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Autoanticorpos/imunologia , Biomarcadores Tumorais/análise , Biomarcadores Tumorais/sangue , Calcitonina/sangue , Calcitonina/normas , Carcinoma Neuroendócrino/sangue , Carcinoma Neuroendócrino/complicações , Carcinoma Neuroendócrino/fisiopatologia , Criança , Estudos de Coortes , Feminino , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Nefropatias/complicações , Nefropatias/fisiopatologia , Testes de Função Renal/normas , Medições Luminescentes/normas , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Radioimunoensaio/métodos , Radioimunoensaio/normas , Valores de Referência , Fatores Sexuais , Neoplasias da Glândula Tireoide/sangue , Neoplasias da Glândula Tireoide/complicações , Neoplasias da Glândula Tireoide/fisiopatologia , Adulto Jovem
4.
J Clin Endocrinol Metab ; 103(11): 3965-3973, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30137438

RESUMO

Context: Current threshold values for primary aldosteronism (PA) diagnostic testing are based on measuring aldosterone (PAC) using immunoassays. Quantification of PAC by liquid chromatography-tandem mass spectrometry (LC-MS/MS) yields lower values. Objective: To compare aldosterone measurement by radioimmunoassay (RIA) with LC-MS/MS and evaluate performances of proposed LC-MS/MS-specific cutoffs for PA screening and confirmatory testing. Patients and Intervention: Forty-one patients underwent aldosterone/renin ratio (ARR) testing to screen for, and fludrocortisone suppression testing (FST) to confirm or exclude, PA. Renin (DRC) was measured by chemiluminescent immunoassay. Results: Median serum PACLC-MS/MS was 27.8% lower (P < 0.05) than plasma PACRIA in 164 pairs of FST samples. A positive correlation (Spearman coefficient, 0.894, P < 0.01; Pearson r coefficient, 0.861, P < 0.01) was observed between the two assays. Thirty-seven patients showed consistent FST diagnoses (29 positive, 8 negative), whereas four showed inconsistent FSTs by the two assays. Good agreement (κ coefficient, 0.736; P < 0.01) was observed between the current FST diagnostic PACRIA cutoff of 165 pmol/L and the proposed PACLC-MS/MS cutoff of 133 pmol/L. Among 37 patients with consistent FST results, no differences were observed in sensitivity (89.7% vs 93.1%) or specificity (87.5% vs 87.5%) for PA screening between the current ARR cutoff of 70 pmol/mU (PACRIA/DRC) and the proposed cutoff of 55 pmol/mU (PACLC-MS/MS/DRC). Conclusions: Adjustment of the current cutoffs for PA diagnostic testing is necessary if PAC is measured by LC-MS/MS. Our preliminary results suggest that the proposed LC-MS/MS cutoffs for ARR and FST perform as well as current RIA cutoffs.


Assuntos
Aldosterona/sangue , Hiperaldosteronismo/diagnóstico , Hipertensão/etiologia , Programas de Rastreamento/normas , Espectrometria de Massas em Tandem/normas , Adulto , Idoso , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Técnicas de Diagnóstico Endócrino/normas , Feminino , Fludrocortisona/administração & dosagem , Humanos , Hiperaldosteronismo/sangue , Hiperaldosteronismo/complicações , Hipertensão/sangue , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Estudos Prospectivos , Radioimunoensaio/métodos , Radioimunoensaio/normas , Renina/sangue , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/métodos
5.
Eur J Endocrinol ; 178(1): 75-82, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29142052

RESUMO

OBJECTIVE: To assess the diagnostic performance of three high-sensitive assays in a cohort of TgAb-negative and TgAb-positive differentiated thyroid cancer (DTC) patients. DESIGN: Retrospective study on prospectively selected DTC patients. METHODS: Serum samples from 154 DTC patients were obtained 6-12 months after radioiodine ablation and tested by Beckman, Roche, BRAHMS Tg and TgAb assays, respectively. Receiver operating characteristics curves for Tg were plotted using outcome over time as benchmark and assay-specific Tg thresholds were obtained for TgAb-negative and TgAb-positive patients. RESULTS: The frequency of positive TgAb was 21, 20 and 20% for Beckman, Roche and BRAHMS, respectively. In TgAb-negative patients, clinical sensitivities and specificities of 100% and 85-95%, respectively, were observed across all assays. In TgAb-positive patients, clinical sensitivities and specificities of 80-100% and 92-96%, respectively, were observed using lower thresholds than in patients without TgAb. CONCLUSIONS: Adopting appropriate thresholds, lower than those for TgAb-negative patients, is possible to reliably follow TgAb-positive patients using highly sensitive Tg assays.


Assuntos
Autoanticorpos/sangue , Tireoglobulina/sangue , Neoplasias da Glândula Tireoide/sangue , Neoplasias da Glândula Tireoide/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radioimunoensaio/normas , Estudos Retrospectivos , Medição de Risco , Neoplasias da Glândula Tireoide/diagnóstico , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
6.
BMC Res Notes ; 10(1): 725, 2017 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-29221487

RESUMO

OBJECTIVE: Thyroglobulin (Tg) measurements assess recurrence in post-thyroidectomy thyroid cancer patients. Tg measurements by enzyme immunoassays (EIA) can be falsely elevated by interference from Tg autoantibodies (TgAb). Radioimmunoassay (RIA) is less susceptible to TgAb interference and has been the standard-of-care test for TgAb positive patients. Recently developed liquid chromatography tandem mass spectrometry (LC-MS/MS) methods may eliminate TgAb interference. We assessed the performance of Tg measurements by EIA, RIA and LC-MS/MS to evaluate TgAb interference differences. RESULTS: We measured TgAb and Tg in 50 plasma samples from 40 patients in whom Tg measurement was part of their routine follow-up and 10 healthy volunteers. Discrepancy between EIA and both LC-MS/MS and RIA was observed at low Tg concentrations (≤ 7.55 ng/mL) in TgAb positive specimens (LC-MS/MS = 1.9 * EIA - 0.03, r = 0.68). RIA and LC-MS/MS Tg measurements in TgAb positive specimens with low Tg concentrations had improved correlation but demonstrated bias (LC MS/MS = 0.6 * RIA - 1.4, r = 0.90). Disagreement between methods may be attributed to LC-MS/MS reported Tg concentrations as undetectable compared to RIA. It seems likely that most discrepant cases are falsely elevated in RIA due to TgAb interference, however, some cases appear below the detection limit of LC-MS/MS; implementation of LC-MS/MS by clinicians will require lower detection limits.


Assuntos
Autoanticorpos/sangue , Cromatografia Líquida/normas , Técnicas Imunoenzimáticas/normas , Radioimunoensaio/normas , Espectrometria de Massas em Tandem/normas , Tireoglobulina/sangue , Tireoglobulina/imunologia , Neoplasias da Glândula Tireoide/diagnóstico , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Glândula Tireoide/sangue
8.
J Labelled Comp Radiopharm ; 60(1): 80-86, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27966236

RESUMO

Radioimmunoassay belongs to the analytical method enabling highly specific and sensitive quantification of molecules. The verification of the real-time radioimmunoassay technology usefulness for ligand-quality characteristics evaluation such as concentration, influence of radiolabeling on binding affinity and stability was estimated. The anti-epidermal growth factor receptor antibody 131 I-cetuximab was employed as the ligand antibody. The concentration of 131 I-cetuximab was derived from the shape of binding curves coming from the ligand-receptor interaction. The binding curves also allowed the estimation of 131 I-cetuximab binding affinity for different radiolabeling procedures (incubation times 1, 5, and 10 minutes) in stability testing up to 96 hours at 4°C. The stability testing also included comparative analysis by size exclusion high-performance liquid chromatography. The assessment of cetuximab concentrations using real-time method showed acceptable accordance between real and calculated values. The real-time method revealed that 1-minute radiolabeling proved to be the optimal incubation time for direct radioiodination of cetuximab. Stability testing showed the significant change in radioligand affinity by one order at the longest incubation times (72 and 96 hours). Characterization of stability and binding behavior of radiolabeled monoclonal antibodies by the verified real-time method before use in other assays may be employed to eliminate variability and suboptimal antibody performance.


Assuntos
Antineoplásicos Imunológicos/química , Cetuximab/química , Radioisótopos do Iodo/química , Ensaio Radioligante/métodos , Compostos Radiofarmacêuticos/química , Antineoplásicos Imunológicos/farmacologia , Linhagem Celular Tumoral , Cetuximab/farmacologia , Humanos , Radioisótopos do Iodo/farmacologia , Ligantes , Radioimunoensaio/métodos , Radioimunoensaio/normas , Ensaio Radioligante/normas , Compostos Radiofarmacêuticos/farmacologia
9.
J Clin Lab Anal ; 31(3)2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27595769

RESUMO

BACKGROUND: Population-based research on vitamin D has increased dramatically in recent years. Such studies are typically reliant on assay procedures to measure reliable and comparable levels of 25-hydroxyvitamin D [25(OH)D] concentrations. METHODS: Concentrations of 25(OH)D3 and 25(OH)D2 were measured using LC-MS/MS in 5,915 participants (aged 31 years) of Northern Finland Birth Cohort 1966. Blood samples were assayed in batches over a course of 18 months. As anomalies were present in the measurements, 200 samples were reassayed using Diasorin RIA. Agreement between measurements was assessed by Passing-Bablok regression and limits of agreement (LoA). To harmonize LC-MS/MS with Diasorin RIA measurements, formulae were derived from the LoA. RESULTS: Concentrations measured by LC-MS/MS were much higher than those measured by Diasorin RIA, with a mean difference of 12.9 ng/ml. Constant variation was evident between batch measurements after log transformation. Statistical formula was applied separately for each batch of LC-MS/MS measurements, enabling us to remove both the constant and proportional bias that was evident prior to the transformation. CONCLUSION: Despite the introduction of schemes/programs to improve accuracy of assays to measure 25(OH)D, significant differences can still happen. In these instances, methods to harmonize measurements based on a relatively small number of replicates can be successfully applied to establish confidence and to enable between-study comparisons.


Assuntos
Cromatografia Líquida/métodos , Programas de Rastreamento , Radioimunoensaio/métodos , Espectrometria de Massas em Tandem/métodos , Vitamina D/análogos & derivados , Calcifediol , Cromatografia Líquida/normas , Estudos de Coortes , Finlândia , Humanos , Modelos Lineares , Programas de Rastreamento/métodos , Programas de Rastreamento/normas , Radioimunoensaio/normas , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/normas , Vitamina D/sangue
10.
Scand J Clin Lab Invest Suppl ; 245: S119-23, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27542000

RESUMO

Patients with differentiated thyroid cancer (DTC) usually have an excellent prognosis. Following surgical and radioiodine treatment to remove the cancer cells and suppressive doses of levothyroxine, long-term follow-up, including measurement of serum thyroglobulin (Tg) using a sensitive assay is required to detect recurrence. To interpret Tg results clinicians need to know the corresponding serum TSH concentration, have an appreciation of the clearance of Tg from patient serum following various interventions and the limitations of its measurement. The limitations of Tg immunoassay are well described and include potential interference from TgAb. For the majority of patients with DTC who are TgAb-negative, Tg measurement remains the most useful method of follow-up. For the TgAb-positive minority, interference and the possibility of producing erroneous results is a concern. Some assays are less badly affected than others and laboratories are advised to choose their assays carefully. Laboratories have sought to identify interferences using measurement of TgAb, lack of concordance between RIAs and immunometric assays and recovery of added Tg. More recently LC-MSMS assays to quantify Tg have been developed. They are not currently as sensitive as Tg immunoassays and it is likely these assays will, like immunoassays, be limited by Tg heterogeneity and standardization issues, although initial evaluations indicate that they may have value in the clinical setting as a second line test in antibody-positive DTC patients in whom Tg is unmeasurable by immunoassay.


Assuntos
Adenocarcinoma/diagnóstico , Biomarcadores Tumorais/sangue , Recidiva Local de Neoplasia/diagnóstico , Tireoglobulina/sangue , Neoplasias da Glândula Tireoide/diagnóstico , Adenocarcinoma/imunologia , Adenocarcinoma/radioterapia , Adenocarcinoma/cirurgia , Adulto , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Feminino , Humanos , Imunoensaio/normas , Imunoglobulinas Estimuladoras da Glândula Tireoide/sangue , Radioisótopos do Iodo/uso terapêutico , Recidiva Local de Neoplasia/imunologia , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/radioterapia , Prognóstico , Radioimunoensaio/normas , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Glândula Tireoide/efeitos dos fármacos , Glândula Tireoide/imunologia , Glândula Tireoide/patologia , Glândula Tireoide/cirurgia , Neoplasias da Glândula Tireoide/imunologia , Neoplasias da Glândula Tireoide/radioterapia , Neoplasias da Glândula Tireoide/cirurgia
11.
J Pharm Biomed Anal ; 118: 307-314, 2016 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-26580828

RESUMO

Histamine (HA) is one of the main immediate mediators involved in allergic reactions. HA plasma concentration is well correlated with the severity of vascular and respiratory signs of anaphylaxis. Consequently, plasma quantification of HA is useful to comfort the diagnosis of anaphylaxis. Currently, radioimmunoassay (RIA) is the gold standard method to quantify HA due to its high sensitivity, but it is time consuming, implicates specific formations and cautions for technicians, and produces hazardous radioactive wastes. The aim of this study was to compare two enzymatic immunoassays (EIA) and one in-house liquid chromatography high-resolution mass spectrometry method (LC-HRMS) with the gold standard method for HA quantification in plasma samples of patients suspected of anaphylaxis reactions. Ninety-two plasma samples were tested with the 4 methods (RIA, 2 EIA and LC-HRMS) for HA quantification. Fifty-eight samples displayed HA concentrations above the positive cut-off of 10nM evaluated by RIA, including 18 highly positive samples (>100 nM). This study shows that Immunotech(®) EIA and LC-HRMS concentrations were highly correlated with RIA values, in particular for samples with a HA concentration around the positive cut-off. In our hands, plasma concentrations obtained with the Demeditec Diagnostics(®) EIA correlated less with results obtained by RIA, and an underestimation of plasma HA levels led to a lack of sensitivity. In conclusion, this study demonstrates that Immunotech(®) EIA and LC-HRMS method could be used instead of RIA to assess plasma HA in human diagnostic use.


Assuntos
Histamina/sangue , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Humanos , Técnicas Imunoenzimáticas , Espectrometria de Massas/métodos , Espectrometria de Massas/normas , Radioimunoensaio/métodos , Radioimunoensaio/normas
13.
J Steroid Biochem Mol Biol ; 148: 41-6, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25239596

RESUMO

The Vitamin D Standardization Program (VDSP) has identified ID-LC/MS/MS as the reference method procedure (RMP) for 25(OH) vitamin D and NIST Standard SRM2972 as the standard reference material (SRM). As manufacturers align their products to the RMP and NIST standard, a concern is that results obtained in aligned assays will be divergent from those obtained with pre-alignment assays. The Immunodiagnostic Systems Ltd., chemiluminescent, 25(OH) vitamin D iSYS platform assay, was recently harmonized to the RMP. To determine the impact of standardization on results obtained with iSYS reagents, 119 single donor serum samples from eight different disease categories were analyzed in four non-standardized and two standardized iSYS assays. There were strong correlations between the four non-standardized and two standardized assays with Spearman's rank r values between 0.975 and 0.961 and four of the eight r values were >0.97. R(2) values for the eight best-fit linear regression equations ranging between 0.947 and 0.916. None of the slopes were found to be significantly different from one another. Bland-Altman plots showed that the bias was comparable when each of the four non-standardized assays was compared to either of the standardized assays. When the data were segregated in values between 6 and 49ng/mL (15-122nmol/L) or between 50 and 100ng/mL (125-250nmol/L) significant associations remained between results obtained with non-standardized and standardized calibrators regardless of the absolute value. When five recent DEQAS unknowns were analyzed in one non-standardized and one standardized assay the mean percent difference from the NIST target in values obtained using standardized vs. non-standardized calibrators were not significantly different. Finally, strong and statistically significant associations between the results were obtained using non-standardized and standardized assays for six of eight clinical conditions. The only exceptions were hypocalcemia and breast cancer, which likely reflect the small sample sizes for each of these diseases. These initial data provide confidence that the move to a NIST standardized assay will have little impact on results obtained with the iSYS platform. This article is part of a Special Issue entitled '17th Vitamin D Workshop'.


Assuntos
Análise Química do Sangue/normas , Doença , Vitamina D/análogos & derivados , Vitamina D/sangue , Automação Laboratorial , Calibragem , Humanos , Medições Luminescentes/normas , Radioimunoensaio/normas , Padrões de Referência , Espectrometria de Massas em Tandem/normas
14.
Ann Clin Biochem ; 50(Pt 5): 421-32, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23847033

RESUMO

BACKGROUND: Serum thyroglobulin (Tg) is useful for monitoring patients with differentiated thyroid cancer (DTC) but is limited by interference from anti-Tg antibodies (TgAb). We determined Tg assay discordance between a radioimmunoassay (RIA) and one of two immunometric assays (IMA) in DTC patients over a 9-year period to gauge assay performance against evidence of recurrent/progressive DTC. METHODS: Patients with DTC monitored for >1 year attending local clinics between September 2000 and January 2010 were included. All samples were analysed for Tg using both RIA and IMA. TgAb were measured on all Tg requests made after May 2006. Bias plots comparing RIA against IMA were established to calculate a 2-SD outlier limit. Clinical records were viewed to compare discordant Tg results against clinical evidence of recurrent/progressive DTC. RESULTS: Discordant Tg results were observed in 53/433 patients (12.2%). Four were discordant owing to a higher IMA result, one of which demonstrated recurrence. The remaining 49 patients demonstrated a disproportionately higher RIA result, of which four had recurrent/persistent disease. Twelve patients with a higher RIA result but no evidence of recurrence underwent thyrogen stimulation testing, which was negative in all 12. In many cases, assay discordance appeared more sensitive at indicating interference than direct measurement of TgAb. CONCLUSIONS: Interference was evident with both Tg assays, such that neither could be solely relied upon to provide the correct result in the presence of TgAb. The concomitant measurement of Tg by RIA and IMA methods should be considered as an alternative to monitoring TgAb status.


Assuntos
Adenocarcinoma Folicular/sangue , Carcinoma/sangue , Recidiva Local de Neoplasia/sangue , Tireoglobulina/sangue , Neoplasias da Glândula Tireoide/sangue , Adenocarcinoma Folicular/diagnóstico , Adolescente , Adulto , Idoso de 80 Anos ou mais , Autoanticorpos/sangue , Carcinoma/diagnóstico , Carcinoma Papilar , Feminino , Humanos , Estudos Longitudinais , Medições Luminescentes/normas , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico , Radioimunoensaio/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tireoglobulina/normas , Câncer Papilífero da Tireoide , Testes de Função Tireóidea , Neoplasias da Glândula Tireoide/diagnóstico
15.
Neurosci Biobehav Rev ; 37(8): 1485-92, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23665533

RESUMO

Research on the neurobiological and behavioral effects of oxytocin (OT), as well as on its possible therapeutic applications, has intensified in the past decade. Accurate determination of peripheral OT levels is essential to reach meaningful conclusions and to motivate, support and inform clinical interventions. Different, but concordant, methods for measuring plasma OT have been developed over the past four decades, but since 2004 several commercially available methods have been favored in research with humans. Evaluation of these methods reveals that they lack reliability when used on unextracted samples of human fluids, and that they tag molecules in addition to OT, yielding estimates that are wildly discrepant with an extensive body of earlier findings that were obtained using methods that are well validated, but more laborious. An accurate, specific, and readily available method for measuring OT that can be adopted as the standard in the field is urgently needed for advances in our understanding of OT's roles in cognition and behavior.


Assuntos
Técnicas Imunoenzimáticas/normas , Ocitocina/sangue , Radioimunoensaio/normas , Humanos , Reprodutibilidade dos Testes
16.
Endocr J ; 60(7): 903-12, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23574729

RESUMO

Subclinical Cushing's syndrome (SCS) associated with adrenal incidentaloma is usually characterized by autonomous cortisol secretion without overt symptoms of Cushing's syndrome (CS). Although the diagnostic criteria for SCS differ among countries, the 1 mg dexamethasone suppression test (DST) is essential to confirm the presence and the extent of cortisol overproduction. Since 1995, SCS has been diagnosed in Japan based on serum cortisol levels ≥3 µg/dL (measured by radioimmunoassay [RIA]) after a 1 mg DST. However, the increasing use of enzyme immunoassays (EIA) instead of RIA has hindered the diagnosis of SCS because of the differing sensitivities of commercially available assays, particularly for serum cortisol levels of around 3 µg/dL. One way to overcome this problem is to lower the cortisol threshold level after a 1 mg DST. In the present study, we examined the clinical applicability of lowering the cortisol threshold to 1.8 µg/dL, similar to the American Endocrine Society's guidelines for CS, by reanalyzing 119 patients with adrenal incidentaloma. Our findings indicate that serum cortisol levels ≥1.8 µg/dL after 1 mg DST are useful to confirm the diagnosis of SCS if both of the following criteria are met: (1) basal ACTH level <10 pg/mL (or poor plasma ACTH response to corticotrophin-releasing hormone) and (2) serum cortisol ≥5 µg/dL at 21:00 to 23:00 h. If only one of (1) and (2) are met, we recommend that other clinical features are considered in the diagnosis of SCS, including serum dehydroepiandrosterone sulfate levels, urine free cortisol levels, adrenal scintigraphy, and clinical manifestation.


Assuntos
Neoplasias das Glândulas Suprarrenais/diagnóstico , Síndrome de Cushing/diagnóstico , Técnicas de Diagnóstico Endócrino , Neoplasias das Glândulas Suprarrenais/sangue , Neoplasias das Glândulas Suprarrenais/complicações , Adulto , Idoso , Doenças Assintomáticas , Síndrome de Cushing/sangue , Síndrome de Cushing/etiologia , Técnicas de Diagnóstico Endócrino/normas , Feminino , Humanos , Hidrocortisona/sangue , Técnicas Imunoenzimáticas/normas , Masculino , Pessoa de Meia-Idade , Radioimunoensaio/normas , Valores de Referência , Adulto Jovem
17.
Clin Chem Lab Med ; 51(7): 1369-83, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23370912

RESUMO

Since its inception in the mid-1980s of the 20th century testing for carbohydrate antigen 19-9 (CA 19-9) has raised expectation for an earlier diagnosis and accurate monitoring of several malignant diseases. After almost 30 years, the available evidences have confirmed the appropriateness and usefulness of determining CA 19-9 levels as a prognostic indicator and as a reliable tool for monitoring pancreatic and gastrointestinal cancer, but concerns have been raised about its applications in screening, which is actually not recommended, and in the diagnosis of malignancies, due to several interferences that limit the specificity and to the insufficient sensitivity of this marker. In this paper we aimed to review the basic concepts of CA 19-9 testing and its current applications, with a major focus on the most recent evidences dealing with assay interference, methods comparison and monitoring of malignant diseases. The prognostic value and monitoring recommendations for pancreatic, gastric and colorectal cancers are described in depth.


Assuntos
Biomarcadores Tumorais/sangue , Antígeno CA-19-9/sangue , Neoplasias Gastrointestinais/diagnóstico , Técnicas Imunoenzimáticas/normas , Neoplasias Pancreáticas/diagnóstico , Anticorpos Monoclonais , Reações Falso-Positivas , Neoplasias Gastrointestinais/sangue , Humanos , Técnicas Imunoenzimáticas/estatística & dados numéricos , Neoplasias Pancreáticas/sangue , Radioimunoensaio/normas , Radioimunoensaio/estatística & dados numéricos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Rinsho Byori ; 60(10): 932-54, 2012 Oct.
Artigo em Japonês | MEDLINE | ID: mdl-23323458

RESUMO

Immunoassay control surveys, were conducted by the Subcommittee for Radioisotope in vitro Test, the Medical Science and Pharmaceutical Committee, and the Japan Radioisotope Association, between 1978 to 2008. A total of 40 analytes for 26 hormones, 14 tumor markers and pharmaceutical drugs were investigated in participating facilities. In the first immunoassay control survey in 1978, samples were measured using only RI kits, however, non-RI kits increased gradually during the next 30 years. In the 30th immunoassay control survey, more than 90% samples were measured using non-RI kits. Coefficient variation (CV) of intra-kits has been decreasing yearly in all analytes for hormones as well as tumor markers. However, improvement of CV in inter-kits has not been seen in the past 30 years by a lack of international standards, although there has been continuous effort over the years for the standardization of immunoassay. Growth hormone (GH) deficiency has been diagnosed using various loading tests. However, the clinical diagnosis varies according to the GH kit used. Standardization for GH measurement has been possible by using recombinant GH as the standard among commercial GH kits. The diagnosis of subclinical Cushing's syndrome also varies according to the cortisol kits being used. Candidate reference measurement procedure and low level cortisol standards have been developed by the Biomedical Standard Section, of the National Metrology Institute of Japan. Standardization of measurement is necessary for improvement of immunoassay.


Assuntos
Radioimunoensaio/métodos , Biomarcadores Tumorais/sangue , Hormônio do Crescimento Humano/sangue , Humanos , Japão , Controle de Qualidade , Radioimunoensaio/normas , Kit de Reagentes para Diagnóstico/normas , Sociedades Médicas , Sociedades Farmacêuticas , Sociedades Científicas , Fatores de Tempo
19.
Pancreas ; 40(7): 1000-5, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21926539

RESUMO

OBJECTIVES: International cooperative group trials require specific, sensitive biomarker assays that are validated between continents. Neurokinin A (NKA) has been shown to be a powerful independent predictor of a poor prognosis in well-differentiated midgut neuroendocrine tumors. We hypothesized that NKA concentrations of clinical specimens evaluated in NKA assays in the United States and the United Kingdom would be equivalent, even though assay techniques were significantly different. METHODS: Frozen clinical specimen aliquots were shipped from the United States to the United Kingdom (n = 67), and from United Kingdom to the United States (n = 50). In addition, spiked plasma standards and medium-spiked standards were exchanged. Samples from the United States were directly assayed in a radioimmunoassay, whereas the UK specimens were extracted, and the reconstituted specimens assayed in the radioimmunoassay. Neurokinin A values from the 2 studies were analyzed by regression analysis. RESULTS: The NKA values from the US and UK laboratories were essentially identical (United States to United Kingdom, r = 0.88, P < 0.0001; and United Kingdom to United States, r = 0.96, P < 0.0001). CONCLUSIONS: Validation of biomarker assays across continents will ensure that laboratory observations made by researchers are equivalent and that prediction of clinical outcomes based on these assays is also reliable.


Assuntos
Biomarcadores Tumorais/sangue , Técnicas de Laboratório Clínico/normas , Tumores Neuroendócrinos/sangue , Neurocinina A/sangue , Radioimunoensaio/normas , Calibragem , Humanos , Estimativa de Kaplan-Meier , Tumores Neuroendócrinos/mortalidade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Padrões de Referência , Análise de Regressão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Manejo de Espécimes/normas
20.
Photochem Photobiol ; 87(4): 935-43, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21534976

RESUMO

We measured serum 25 hydroxyvitamin D [25(OH)D] levels of ambulatory adults in tropical Australia to determine whether it is appropriate to continue promoting sun-safety in this population. In August 2006 (winter), self-administered questionnaires were completed by 145 Meals-on-Wheels volunteers (49.3% male; mean age 57.8 ± 14.7 years; 76.6% response) from Townsville, Queensland (Latitude 19(o) S). Serum 25(OH)D was analyzed using two common assays. Mean levels were 68.3 (SD ± 18.7; range 26-142) by DiaSorin Radioimmunoassay and 83.0 (SD ± 30.8; range 30-184) by DiaSorin Liaison® one. No participants were 25(OH)D deficient (<25 nmol L(-1)). Nine participants (6.2%) had 25(OH)D levels between 25 and 50 nmol L(-1) (insufficient), by both methods (seven with a BMI ≥ 25). Twenty-eight participants (19.3%) had one result in the insufficient range and the other in the adequate range. Thus, almost all of these free-living adults in tropical Australia had adequate vitamin D levels at the end of winter. There was poor agreement between the two 25(OH)D assays. These results suggest it is appropriate to continue promoting sun-safe messages to the ambulatory Caucasian adult population of North Queensland, which has an extremely high incidence of skin cancer. The lack of agreement between the two assays is a concern. Few doctors are aware of this measurement issue.


Assuntos
Exposição Ocupacional/análise , Radioimunoensaio/normas , Raios Ultravioleta/efeitos adversos , Vitamina D/sangue , Adolescente , Adulto , Idoso , Estudos Transversais , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Saúde Pública , Queensland/epidemiologia , Reprodutibilidade dos Testes , Estações do Ano , Luz Solar/efeitos adversos , Inquéritos e Questionários , Clima Tropical , Deficiência de Vitamina D/sangue , Deficiência de Vitamina D/epidemiologia , População Branca
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA