Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 15.725
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 10581, 2024 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719925

RESUMO

This research is dedicated to exploring the dynamics of milling chatter stability in orthopedic surgery robots, focusing on the impact of position modal parameters on chatter stability. Initially, we develop a dynamic milling force model for the robotic milling process that integrates both modal coupling and regenerative effects. We then employ the zero-order frequency domain method to derive a chatter stability domain model, visually represented through stability lobe diagrams (SLDs). Through conducting hammer test experiments, we ascertain the robot's modal parameters at varying positions, enabling the precise generation of SLDs. This study also includes experimental validation of the chatter SLD analysis method, laying the groundwork for further examination of chatter stability across different positional modal parameters. Finally, our analysis of the variations in modal parameters on the stability of robot milling chatter yields a theoretical framework for optimizing cutting parameters and developing control strategies within the context of orthopedic surgery robots.


Assuntos
Procedimentos Ortopédicos , Procedimentos Ortopédicos/métodos , Procedimentos Ortopédicos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Robótica/métodos , Modelos Teóricos , Humanos , Desenho de Equipamento
2.
J Pak Med Assoc ; 74(4 (Supple-4)): S79-S84, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38712413

RESUMO

Dental Robotics represent a groundbreaking technological frontier with the potential to disrupt traditional paradigms in oral healthcare. This abstract explores the transformative impact of robotic applications in dentistry, focussing on precision, reproducibility, and reliability. A comprehensive search was conducted on the PubMed database, Dental and Oral Science, and CINAHL to identify pertinent studies exploring the implications of robotics in dentistry. Studies incorporated in this analysis highlighted the significance of broadening the research scope beyond implantology. This review underscores the importance of integrating robotic dentistry into educational frameworks and advancing technological preparedness. As we navigate these challenges, the abstract underscores the pivotal role of robotic dentistry in shaping the future of oral healthcare. Robotic dentistry promises transformative advancements in oral healthcare with precision and reliability. Challenges like limited system availability and expertise highlight the need for increased dentist-engineer collaboration. Diversifying research, emphasizing non-invasive technologies, and integrating robotic dentistry into education are crucial for wider acceptance. Public awareness and regulatory clarity are pivotal for seamless integration, unlocking the vast potential of robotic technologies in the future of dental care.


Assuntos
Robótica , Humanos , Odontologia , Procedimentos Cirúrgicos Robóticos/métodos
3.
Nat Commun ; 15(1): 4004, 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38734697

RESUMO

The current thyroid ultrasound relies heavily on the experience and skills of the sonographer and the expertise of the radiologist, and the process is physically and cognitively exhausting. In this paper, we report a fully autonomous robotic ultrasound system, which is able to scan thyroid regions without human assistance and identify malignant nod- ules. In this system, human skeleton point recognition, reinforcement learning, and force feedback are used to deal with the difficulties in locating thyroid targets. The orientation of the ultrasound probe is adjusted dynamically via Bayesian optimization. Experimental results on human participants demonstrated that this system can perform high-quality ultrasound scans, close to manual scans obtained by clinicians. Additionally, it has the potential to detect thyroid nodules and provide data on nodule characteristics for American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) calculation.


Assuntos
Robótica , Glândula Tireoide , Nódulo da Glândula Tireoide , Ultrassonografia , Humanos , Glândula Tireoide/diagnóstico por imagem , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Robótica/métodos , Robótica/instrumentação , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Teorema de Bayes , Feminino , Adulto , Masculino , Neoplasias da Glândula Tireoide/diagnóstico por imagem
4.
Neurosurg Rev ; 47(1): 214, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38727832

RESUMO

The letter critically evaluates the role of robotic applications in cerebral aneurysm neurointerventions, synthesizing a diverse array of studies to elucidate both the potential benefits and inherent limitations of this emerging technology. The review highlights the advancements in precision, efficiency, and patient outcomes facilitated by robotic platforms, while also acknowledging challenges such as the steep learning curve and the need for further research to establish long-term efficacy and cost-effectiveness. By navigating through the complexities of robotic-assisted neurosurgery, the review provides valuable insights into the transformative potential of robotics in optimizing treatment paradigms and improving patient care.


Assuntos
Aneurisma Intracraniano , Procedimentos Neurocirúrgicos , Procedimentos Cirúrgicos Robóticos , Aneurisma Intracraniano/cirurgia , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Neurocirúrgicos/métodos , Procedimentos Endovasculares/métodos , Robótica/métodos
5.
Nat Commun ; 15(1): 3759, 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38704384

RESUMO

Millimeter-scale soft continuum robots offer safety and adaptability in transluminal procedures due to their passive compliance, but this feature necessitates interactions with surrounding lumina, leading to potential medical risks and restricted mobility. Here, we introduce a millimeter-scale continuum robot, enabling apical extension while maintaining structural stability. Utilizing phase transition components, the robot executes cycles of tip-based elongation, steered accurately through programmable magnetic fields. Each motion cycle features a solid-like backbone for stability, and a liquid-like component for advancement, thereby enabling autonomous shaping without reliance on environmental interactions. Together with clinical imaging technologies, we demonstrate the capability of navigating through tortuous and fragile lumina to transport microsurgical tools. Once it reaches larger anatomical spaces such as stomach, it can morph into functional 3D structures that serve as surgical tools or sensing units, overcoming the constraints of initially narrow pathways. By leveraging this design paradigm, we anticipate enhanced safety, multi-functionality, and cooperative capabilities among millimeter-scale continuum robots, opening new avenues for transluminal robotic surgery.


Assuntos
Procedimentos Cirúrgicos Robóticos , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Humanos , Desenho de Equipamento , Robótica/instrumentação , Robótica/métodos , Campos Magnéticos , Microcirurgia/instrumentação , Microcirurgia/métodos , Animais , Magnetismo
6.
Int J Mol Sci ; 25(9)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38732200

RESUMO

We are living in an era of advanced nanoscience and nanotechnology. Numerous nanomaterials, culminating in nanorobots, have demonstrated ingenious applications in biomedicine, including breast cancer (BC) nano-theranostics. To solve the complicated problem of BC heterogeneity, non-targeted drug distribution, invasive diagnostics or surgery, resistance to classic onco-therapies and real-time monitoring of tumors, nanorobots are designed to perform multiple tasks at a small scale, even at the organelles or molecular level. Over the last few years, most nanorobots have been bioengineered as biomimetic and biocompatible nano(bio)structures, resembling different organisms and cells, such as urchin, spider, octopus, fish, spermatozoon, flagellar bacterium or helicoidal cyanobacterium. In this review, readers will be able to deepen their knowledge of the structure, behavior and role of several types of nanorobots, among other nanomaterials, in BC theranostics. We summarized here the characteristics of many functionalized nanodevices designed to counteract the main neoplastic hallmark features of BC, from sustaining proliferation and evading anti-growth signaling and resisting programmed cell death to inducing angiogenesis, activating invasion and metastasis, preventing genomic instability, avoiding immune destruction and deregulating autophagy. Most of these nanorobots function as targeted and self-propelled smart nano-carriers or nano-drug delivery systems (nano-DDSs), enhancing the efficiency and safety of chemo-, radio- or photodynamic therapy, or the current imagistic techniques used in BC diagnosis. Most of these nanorobots have been tested in vitro, using various BC cell lines, as well as in vivo, mainly based on mice models. We are still waiting for nanorobots that are low-cost, as well as for a wider transition of these favorable effects from laboratory to clinical practice.


Assuntos
Neoplasias da Mama , Nanotecnologia , Humanos , Neoplasias da Mama/patologia , Neoplasias da Mama/terapia , Neoplasias da Mama/diagnóstico , Feminino , Nanotecnologia/métodos , Animais , Nanoestruturas/química , Nanoestruturas/uso terapêutico , Robótica/métodos , Nanomedicina Teranóstica/métodos , Sistemas de Liberação de Medicamentos/métodos , Antineoplásicos/uso terapêutico , Antineoplásicos/farmacologia
7.
Sensors (Basel) ; 24(9)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38732782

RESUMO

In robot-assisted microsurgery (RAMS), surgeons often face the challenge of operating with minimal feedback, particularly lacking in haptic feedback. However, most traditional desktop haptic devices have restricted operational areas and limited dexterity. This report describes a novel, lightweight, and low-budget wearable haptic controller for teleoperated microsurgical robotic systems. We designed a wearable haptic interface entirely made using off-the-shelf material-PolyJet Photopolymer, fabricated using liquid and solid hybrid 3D co-printing technology. This interface was designed to resemble human soft tissues and can be wrapped around the fingertips, offering direct contact feedback to the operator. We also demonstrated that the device can be easily integrated with our motion tracking system for remote microsurgery. Two motion tracking methods, marker-based and marker-less, were compared in trajectory-tracking experiments at different depths to find the most effective motion tracking method for our RAMS system. The results indicate that within the 4 to 8 cm tracking range, the marker-based method achieved exceptional detection rates. Furthermore, the performance of three fusion algorithms was compared to establish the unscented Kalman filter as the most accurate and reliable. The effectiveness of the wearable haptic controller was evaluated through user studies focusing on the usefulness of haptic feedback. The results revealed that haptic feedback significantly enhances depth perception for operators during teleoperated RAMS.


Assuntos
Microcirurgia , Procedimentos Cirúrgicos Robóticos , Dispositivos Eletrônicos Vestíveis , Humanos , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Microcirurgia/instrumentação , Algoritmos , Robótica/instrumentação , Desenho de Equipamento , Impressão Tridimensional
8.
J Robot Surg ; 18(1): 176, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630145

RESUMO

The objective is to preliminary evaluated postoperative leukocyte counts as a surrogate for the surgical stress response in NSCLC patients who underwent RATS or VATS for further prospective analyses with proper assessment of surgical stress response and tissue trauma. We retrospectively analyzed patients with stageI-IIIA NSCLC who underwent RATS or VATS at a hospital between 8 May 2020 and 31 December 2021. Analysis of leukocytes (including neutrophils and lymphocytes) and albumin on postoperative days (PODs) 1 and 3 in patients with NSCLC treated with RATS or VATS after propensity score matching (PSM). In total, 1824 patients (565 RATS and 1259 VATS) were investigated. The two MIS groups differed significantly with regard to operative time (p < 0.001), chronic lung disease (p < 0.001), the type of pulmonary resection (p < 0.001), the excision site of lobectomy (p = 0.004), and histology of the tumor (p = 0.028). After PSM, leukocyte and neutrophil levels in the RATS group were lower than those in the VATS group on PODs 1 and 3, with those on POD 3 (p < 0.001) being particularly notable. While lymphocyte levels in the RATS group were significantly lower than those in the VATS group only at POD 1 (p = 0.016). There was no difference in albumin levels between the RATS and VATS groups on PODs 1 and 3. The surgical stress response and tissue trauma was less severe in NSCLC patients who underwent RATS than in those who underwent VATS, especially reflected in the neutrophils of leukocytes.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Cirurgia Torácica Vídeoassistida , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/métodos , Contagem de Leucócitos , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Albuminas , Neoplasias Pulmonares/cirurgia
9.
BMC Surg ; 24(1): 109, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38614996

RESUMO

PURPOSE: Patent processus vaginalis (PPV) is usually observed in pediatric abdominal surgery; however, robotic single-port surgery in repairing processus vaginalis has not been reported in children. Herein, we present our clinical experiences in single-port robotic surgeries for PPV repair to evaluate both efficacy and safety. METHODS: Retrospective analysis of patients underwent single-port robotic-assisted laparoscopic surgery for genitourinary diseases from May 2020 and May 2023 in our center. Among these patients, 21 children had PPV repaired at the same time. The case characteristics and follow-up data were recorded. RESULTS: Twenty-one of the 53 children were found to have PPV during genitourinary surgery. The simultaneous treatment of the primary disease and PPV with a single-port robotic-assisted platform was both convenient and safe. There was no significant increase in total operation time, and no excessive intraoperative hemorrhage was observed in any of the operations. There were no complications observed on follow-up. CONCLUSION: With a high incidence of PPV in children, a single-port robotic-assisted procedure is feasible and effective if simultaneously performed when addressing a primary abdominal disease.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Criança , Estudos Retrospectivos , Perda Sanguínea Cirúrgica
10.
Physiother Res Int ; 29(2): e2091, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38642068

RESUMO

INTRODUCTION: Stroke has emerged as the leading cause of disability globally. The provision of long-term rehabilitation to stroke survivors poses a health care burden to many countries. Robotic devices have created a major turning point in stroke rehabilitation program. Currently, the anthropometric evidence to support the benefit of robotic rehabilitation (RR) among stroke patients is scarce. Therefore, the aim of this study was to evaluate the impact of RR on the mid-thigh circumferences of the paretic limbs in stroke patients. METHODS: Twenty stroke patients from conventional rehabilitation (CR) (n = 10) and RR (n = 10) groups were recruited through a purposive sampling method. Patients in the CR group received a two-hour session of a five-day-a-week home-based CR program for 4 weeks. Patients in the RR group received a five-day-a-week of an hour combined physiotherapy and occupational therapy session and a one-hour robotic therapy session using the HAL® Cyberdyne lower-limb, for 4 weeks. The mid-thigh circumferences of both limbs were measured on day 1 (baseline), week 2 and week 4 of rehabilitation program. RESULTS: The results revealed no statistically significant difference in the mid-thigh circumferences between the paretic (F1.05,9.44 = 1.96, p = 0.20), and the normal (F1.05,9.44 = 1.96, p = 0.20) sides in the CR group (n = 10). For the comparison between the paretic and normal sides in the RR group (n = 10), the paretic mid-thigh circumferences revealed significant time effect results (F2,18 = 11.91, p = 0.001), which were due to changes between baseline and week 2, and baseline and week 4 measurements. Interestingly, the normal mid-thigh circumferences also revealed a significant time effect (F2,18 = 6.56, p = 0.007), which is due to changes between baseline and week 4. One-way analysis of variance was employed to compare the mean average between groups due to the difference in the baseline measurements of the mid-thigh circumferences between the paretic side of the CR and the RR groups. With this adjustment, the average means mid-thigh circumferences after 4 weeks of therapy were shown to be significantly different between the CR and RR groups (F1,18 = 12.49, p = 0.02). CONCLUSION: Significant increments in the mid-thigh circumferences following RR were seen in the paretic limbs of stroke patients. Hence, this study may provide some insights into further potential research related to the benefits of RR in stroke patients.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Coxa da Perna , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/terapia , Reabilitação do Acidente Vascular Cerebral/métodos , Robótica/métodos
11.
Sensors (Basel) ; 24(8)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38676202

RESUMO

Haptic hands and grippers, designed to enable skillful object manipulation, are pivotal for high-precision interaction with environments. These technologies are particularly vital in fields such as minimally invasive surgery, where they enhance surgical accuracy and tactile feedback: in the development of advanced prosthetic limbs, offering users improved functionality and a more natural sense of touch, and within industrial automation and manufacturing, they contribute to more efficient, safe, and flexible production processes. This paper presents the development of a two-finger robotic hand that employs simple yet precise strategies to manipulate objects without damaging or dropping them. Our innovative approach fused force-sensitive resistor (FSR) sensors with the average current of servomotors to enhance both the speed and accuracy of grasping. Therefore, we aim to create a grasping mechanism that is more dexterous than grippers and less complex than robotic hands. To achieve this goal, we designed a two-finger robotic hand with two degrees of freedom on each finger; an FSR was integrated into each fingertip to enable object categorization and the detection of the initial contact. Subsequently, servomotor currents were monitored continuously to implement impedance control and maintain the grasp of objects in a wide range of stiffness. The proposed hand categorized objects' stiffness upon initial contact and exerted accurate force by fusing FSR and the motor currents. An experimental test was conducted using a Yale-CMU-Berkeley (YCB) object set consisted of a foam ball, an empty soda can, an apple, a glass cup, a plastic cup, and a small milk packet. The robotic hand successfully picked up these objects from a table and sat them down without inflicting any damage or dropping them midway. Our results represent a significant step forward in developing haptic robotic hands with advanced object perception and manipulation capabilities.


Assuntos
Dedos , Força da Mão , Robótica , Tato , Robótica/métodos , Robótica/instrumentação , Humanos , Dedos/fisiologia , Tato/fisiologia , Força da Mão/fisiologia , Impedância Elétrica , Mãos/fisiologia , Desenho de Equipamento
12.
World J Urol ; 42(1): 232, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38613597

RESUMO

PURPOSE: Robot-assisted radical prostatectomy (RARP) is a common surgical procedure for the treatment of prostate cancer. Although beneficial, it can lead to intraoperative hypoxia due to high-pressure pneumoperitoneum and Trendelenburg position. This study explored the use of oxygen reserve index (ORi) to monitor and predict hypoxia during RARP. METHODS: A retrospective analysis was conducted on 329 patients who underwent RARP at the Seoul National University Bundang Hospital between July 2021 and March 2023. Various pre- and intraoperative variables were collected, including ORi values. The relationship between ORi values and hypoxia occurrence was assessed using receiver operating characteristic curves and logistic regression analysis. RESULTS: Intraoperative hypoxia occurred in 18.8% of the patients. The receiver operating characteristic curve showed a satisfactory area under the curve of 0.762, with the ideal ORi cut-off value for predicting hypoxia set at 0.16. Sensitivity and specificity were 64.5% and 75.7%, respectively. An ORi value of < 0.16 and a higher body mass index were identified as independent risk factors of hypoxia during RARP. CONCLUSIONS: ORi monitoring provides a non-invasive approach to predict intraoperative hypoxia during RARP, enabling early management. Additionally, the significant relationship between a higher body mass index and hypoxia underscores the importance of individualized patient assessment.


Assuntos
Oxigênio , Robótica , Masculino , Humanos , Estudos Retrospectivos , Prostatectomia , Hipóxia/etiologia
13.
J Orthop Surg Res ; 19(1): 246, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632565

RESUMO

Background Tunnel placement is a key step in anterior cruciate ligament (ACL) reconstruction. The purpose of this study was to evaluate the accuracy of bone tunnel drilling in arthroscopic ACL reconstruction assisted by a three-dimensional (3D) image-based robot system. Methods Robot-assisted ACL reconstruction was performed on twelve freshly frozen knee specimens. During the operation, three-dimensional images were used for ACL bone tunnel planning, and the robotic arm was used for navigation and drilling. Twelve patients who underwent traditional arthroscopic ACL reconstruction were included. 3D computed tomography was used to measure the actual position of the ACL bone tunnel and to evaluate the accuracy of the robotic and traditional ACL bone tunnel. Results On the femoral side, the positions of robotic and traditional surgery tunnels were 29.3 ± 1.4% and 32.1 ± 3.9% in the deep-to-shallow direction of the lateral femoral condyle (p = 0.032), and 34.6 ± 1.2% and 21.2 ± 9.4% in the high-to-low direction (p < 0.001), respectively. On the tibial side, the positions of the robotic and traditional surgical tunnels were located at 48.4 ± 0.9% and 45.8 ± 2.8% of the medial-to-lateral diameter of the tibial plateau (p = 0.008), 38.1 ± 0.8% and 34.6 ± 6.0% of the anterior-to-posterior diameter (p = 0.071), respectively. Conclusions In this study, ACL reconstruction was completed with the assistance of a robot arm and 3D images, and the robot was able to drill the bone tunnel more accurately than the traditional arthroscopic ACL reconstruction.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Robótica , Humanos , Imageamento Tridimensional , Tomografia Computadorizada por Raios X , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Fêmur/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Lesões do Ligamento Cruzado Anterior/cirurgia
14.
BMC Urol ; 24(1): 92, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643097

RESUMO

PURPOSE: This study aimed to investigate the effects of two different positions on lower extremity hemodynamics during robot-assisted laparoscopic radical prostatectomy (RARP) for prostate cancer. METHODS: A total of 196 patients who underwent RARP in our hospital from February 2020 to March 2022 were included in this study. Among them, 98 patients who underwent surgery with the Trendelenburg position and split-leg position with calf reverse arch from March 2021 to March 2022 were assigned to the observation group, while 98 patients who underwent surgery with the Trendelenburg position and low lithotomy position from February 2020 to February 2021 were assigned to the control group. Using an ultrasound diagnostic instrument to detect the internal diameter, mean blood flow velocity, and mean blood flow volume of the left deep femoral vein at different times, such as the supine position (T0), after 5 minutes of placing the patient in the leg spilt or low lithotomy position (T1), after 5 minutes of pneumoperitoneum (T2), after 5 minutes of head-down tilt or head-down tilt and calf reverse arch (T3), 1.5 hours after the start of surgery (T4), before the removal of CO2 gas (T5), and before the patient left the operating room (T6). As well as the patency of deep venous blood flow in both lower extremities before leaving the operating room, RESULTS: After establishment of pneumoperitoneum, the internal diameter of the deep femoral vein increased significantly, while the mean blood flow velocity and mean blood flow volume decreased significantly in both groups(T0) (P<0.001). With the prolongation of surgical time, the impact on lower extremity hemodynamics in the observation group was smaller than that in the control group. From T2 to T6, the internal diameter of the femoral vein in the observation group was smaller than that in the control group, while the mean blood flow velocity and mean blood flow volume were increased compared to the control group (P<0.05). Before leaving the operating room, the patency of deep venous blood flow in the observation group was better than that in the control group (P=0.003). CONCLUSION: Placing patients in the Trendelenburg position and split-leg position with calf reverse arch during RARP for prostate cancer has a smaller impact on lower extremity hemodynamics than the low lithotomy position, and can relatively reduce the risk of postoperative deep vein thrombosis.


Assuntos
Laparoscopia , Pneumoperitônio , Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Hemodinâmica/fisiologia , Prostatectomia , Extremidade Inferior , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia
15.
World J Urol ; 42(1): 245, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643347

RESUMO

PURPOSE: To provide a comprehensive update on the different techniques and outcomes of contemporary Single-Port (SP) Robotic Radical Prostatectomy (RARP) approaches. METHODS: A literature review was performed to identify cohort studies that have utilized the purpose-built SP robotic platform (Intuitive Surgical Inc., Sunnyvale, California) for RARP. All published approaches of SP-RARP were included in our review. Baseline clinical, perioperative, and postoperative oncological and functional outcomes were collected from the included studies. RESULTS: A total of 16 studies involving 1159 patients were identified. To date, five approaches of SP-RARP have been described, namely Transperitoneal, Extraperitoneal, Retzius-Sparing, Transperineal, and Transvesical. The surgical steps and clinical outcomes of the aforementioned approaches were discussed. While operating times were still faster in the Transperitoneal and Extraperitoneal cohorts, the novel and more regionalized Transvesical approach allowed for radical prostatectomy to be pursued in more patients with previous abdominal surgeries and contributed to significantly improved postoperative outcomes, including the earlier return of urinary continence and with most patients being discharged on the same day without any opioids. CONCLUSION: Based on the existing literature, the introduction of SP-RARP not only enriched the repertoire of minimally-invasive surgical treatment options for prostate cancer but also provided the opportunity for urologists to develop new techniques that can improve perioperative outcomes and postoperative quality of life. Given the limited number of patients and heterogeneity in the patient selection and reporting of postoperative outcomes, further research remains necessary to better understand the different benefits and improve patient selection algorithms for the different techniques.


Assuntos
Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Qualidade de Vida , Próstata/cirurgia , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Resultado do Tratamento
16.
Sci Rep ; 14(1): 8658, 2024 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622320

RESUMO

The study aimed to evaluate the impact of abdominal drain placement (vs. omission) on perioperative outcomes of robot-assisted partial nephrectomy (RAPN), focusing on complications, time to canalization, deambulation, and pain management. A prospectively-maintained institutional database was queried to get data of patients who underwent RAPN for renal masses between January 2018 and May 2023 at our Institution. Baseline, surgical, and postoperative data were collected. Retrieved patients were stratified based upon placement of abdominal drain (Y/N). Descriptive analyses comparing the two groups were conducted as appropriate.77 After adjusting for potential confounders, a logistic regression analysis was conducted to evaluate significant predictors of any grade and "major" complications. 342 patients were included: 192 patients in the "drain group" versus 150 patients in the "no-drain" group. Renal masses were larger (p < 0.001) and at higher complexity (RENAL score, p = 0.01), in the drain group. Procedures in the drain group had statistically significantly longer operative time, ischemia time, and higher blood loss (all p-values < 0.001). The urinary collecting system was more likely involved compared to the no-drain group (p = 0.01). At multivariate analysis, abdominal drainage was not a significant predictor of any grade (OR 0.79, 95%CI 0.33-1.87) and major postoperative complications (OR 3.62, 95%CI 0.53-9.68). Patients in the drain group experienced a statistically significantly higher hemoglobin drop (p < 0.01). Moreover, they exhibited statistically significant higher paracetamol consumption (p < 0.001) and need for additional opioids (p = 0.02). In summary, the study results suggest the safety of omitting drain placement and remark on the need for personalized decision-making, which considers patient and procedural factors.


Assuntos
Neoplasias Renais , Robótica , Humanos , Neoplasias Renais/cirurgia , Resultado do Tratamento , Nefrectomia/efeitos adversos , Nefrectomia/métodos , Rim/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos
17.
Sci Rep ; 14(1): 8750, 2024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627418

RESUMO

This paper introduces a novel cable-driven robotic platform that enables six degrees-of-freedom (DoF) natural head-neck movements. Poor postural control of the head-neck can be a debilitating symptom of neurological disorders such as amyotrophic lateral sclerosis and cerebral palsy. Current treatments using static neck collars are inadequate, and there is a need to develop new devices to empower movements and facilitate physical rehabilitation of the head-neck. State-of-the-art neck exoskeletons using lower DoF mechanisms with rigid linkages are limited by their hard motion constraints imposed on head-neck movements. By contrast, the cable-driven robot presented in this paper does not constrain motion and enables wide-range, 6-DoF control of the head-neck. We present the mechatronic design, validation, and control implementations of this robot, as well as a human experiment to demonstrate a potential use case of this versatile robot for rehabilitation. Participants were engaged in a target reaching task while the robot applied both assistive and resistive moments on the head during the task. Our results show that neck muscle activation increased by 19% when moving the head against resistance and decreased by 28-43% when assisted by the robot. Overall, these results provide a scientific justification for further research in enabling movement and identifying personalized rehabilitation for motor training. Beyond rehabilitation, other applications such as applying force perturbations on the head to study sensory integration and applying traction to achieve pain relief may benefit from the innovation of this robotic platform which is capable of applying controlled 6-DoF forces/moments on the head.


Assuntos
Exoesqueleto Energizado , Doenças do Sistema Nervoso , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Robótica/métodos , Movimento/fisiologia , Movimentos da Cabeça/fisiologia
18.
J Robot Surg ; 18(1): 179, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38642236

RESUMO

Upper extremity complications are often a problem in robot-assisted pelvic surgery (RAPS) with the lithotomy-Trendelenburg position (LT-position). This study focused on upper extremity contact pressure (UEP) and examined the relationship between UEP and upper extremity complications. From May 2020 to April 2022 at the University of Tokyo Hospital, UEP was measured in 155 patients undergoing RARP and 20 patients undergoing RARC. A total of 350 sets of UEP were investigated in this study. UEP was measured using a portable interface pressure sensor (Palm Q, Cape CO., Kanagawa, Japan) in the preoperative lithotripsy position (L-position), preoperative LT-position, and postoperative L-position. UEP was increased in the preoperative LT-position than in the preoperative L-position (right side 5.2 mmHg vs. 17.1 mmHg, left side 5.3 mmHg vs. 17.1 mmHg, P < 0.001, respectively), and was decreased in the postoperative L-position than in preoperative LT-position (right side 17.1 mmHg vs. 10.8 mmHg, left side 17.1 mmHg vs. 10.6 mmHg, P < 0.001, respectively). Eleven upper extremities developed shoulder pain. UEP of the preoperative LT-position tended to be higher in the upper extremity exhibiting shoulder pain (25.6 mmHg (15.4-30.3) vs. 17.1 mmHg (12.0-24.4) P = 0.0901). UEP measurements may help prevent postoperative shoulder pain.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Masculino , Procedimentos Cirúrgicos Robóticos/métodos , Dor de Ombro , Extremidade Superior , Prostatectomia
19.
Langenbecks Arch Surg ; 409(1): 118, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38600407

RESUMO

PURPOSE: Due to improved survival of esophageal cancer patients, long-term quality of life (QoL) is increasingly gaining importance. The aim of this study is to compare QoL outcomes between open Ivor Lewis esophagectomy (Open-E) and a hybrid approach including laparotomy and a robot-assisted thoracic phase (hRob-E). Additionally, a standard group of healthy individuals serves as reference. METHODS: With a median follow-up of 36 months after hRob-E (n = 28) and 40 months after Open-E (n = 43), patients' QoL was assessed using the European Organization for Research and Treatment of Cancer (EORTC) QoL Questionnaire Core 30 (QLQ-C30) and the EORTC Esophagus specific QoL questionnaire 18 (QLQ-OES18). RESULTS: Patients showed similar clinical-pathological characteristics, but hRob-E patients had significantly higher ASA scores at surgery (p < 0.001). Patients and healthy controls reported similar global health status and emotional and cognitive functions. However, physical functioning of Open-E patients was significantly reduced compared to healthy controls (p = 0.019). Operated patients reported reduced role and social functioning, fatigue, nausea and vomiting, dyspnea, and diarrhea. A trend towards a better pain score after hRob-E compared to Open-E emerged (p = 0.063). Regarding QLQ-OES18, hRob-E- and Open-E-treated patients similarly reported eating problems, reflux, and troubles swallowing saliva. CONCLUSIONS: The global health status is not impaired after esophagectomy. Despite higher ASA scores, QoL of hRob-E patients is similar to that of patients operated with Open-E. Moreover, patients after hRob-E appear to have a better score regarding physical functioning and a better pain profile than patients after Open-E, indicating a benefit of minimally invasive surgery.


Assuntos
Neoplasias Esofágicas , Robótica , Humanos , Qualidade de Vida , Esofagectomia , Inquéritos e Questionários , Neoplasias Esofágicas/cirurgia , Dor
20.
Neurosurg Rev ; 47(1): 150, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38600417

RESUMO

Cerebral aneurysm is a life-threatening condition, which requires high precision during the neurosurgical procedures. Increasing progress of evaluating modern devices in medicine have led to common usage of robotic systems in many fields, including cranial aneurysm operations. However, currently no systematic review describes up-to date knowledge of this topic. Following PRISMA guidelines, we have independently screened and extracted works from seven databases. Only studies fulfilling inclusion criteria were presented in this study. Device used, operation time, complications, aneurysm type and patient demographics were extracted from each work. We identified a total of 995 articles from databases. We have found six original works and one supplementary article eligible for this synthesis. Majority of works (4/6) have implemented CorPath GRX in cerebral aneurysm procedures. The procedures involved diverse aneurysm locations, utilizing flow diverters, stents, or coiling. One study described implementation of robot-assist on 117 patients and compared results to randomized clinical trials. One work with a small patient cohort described use of the magnetically-controlled microguidewire in the coiling procedures, without any complications. Additionally, one case-series study described use of a robotic arm for managing intraoperative aneurysm rupture. Currently, robotical devices for cerebral aneurysm treatment mainly lack jailing and haptic feedback feature. Further development of these devices will certainly be beneficial for operators and patients, allowing for more precise and remote surgeries.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Stents , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA