Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 155
Filtrar
1.
Zhongguo Yi Liao Qi Xie Za Zhi ; 47(1): 32-37, 2023 Jan 30.
Artigo em Chinês | MEDLINE | ID: mdl-36752003

RESUMO

Characteristics of two major categories of RA equipment which defined in the standard are interpreted firstly. Few representative RA equipment in current market and their key product features are introduced. Then, classifications of different indexes of spatial positioning accuracy are declared, the difficulties of performing testing process on each indexes are further explained. Meanwhile, different kinds of three dimensional coordinate measuring equipment that are cutting edge at present stage are introduced with their main methods of use explained. According to characteristics of three dimensional coordinate measuring equipment on the market, proper measuring equipment for testing certain index of spatial positioning accuracy and corresponding experiment method are introduced.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Robótica/instrumentação , Robótica/normas , Procedimentos Cirúrgicos Robóticos/instrumentação
2.
Tex Heart Inst J ; 49(2)2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35481863

RESUMO

After the introduction of the first robotic-assisted surgical procedures, the technology soon reached the world of endovascular specialists, giving rise to several publications about robotic-assisted endovascular therapy. Compared with conventional procedures, robotic-assisted procedures can be more accurate and reduce radiation exposure. The latest commercially available endovascular robotic system is the CorPath GRX, which can be operated remotely. Robotic-assisted approaches have proved applicable in the fields of coronary and peripheral vascular intervention and neurointervention. Remote intervention has already proved feasible in the coronary and peripheral vascular systems and, according to expert opinion, could revolutionize acute stroke management as well. We review current knowledge about robotic-assisted therapies and remote interventions, and the future prospects and pitfalls.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Procedimentos Cirúrgicos Robóticos , Robótica , Doença da Artéria Coronariana/cirurgia , Humanos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Robótica/métodos , Robótica/normas , Resultado do Tratamento
4.
J Oncol Pharm Pract ; 26(2): 312-324, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30997871

RESUMO

KIRO® Oncology (Kiro Grifols, Spain) is a robotic system for automated compounding of sterile injectable drugs including intravenous cytotoxic treatments. The present article describes the qualification procedure applied prior to production phases. Peristaltic pumps which ensure the reconstitution of drugs were tested with water and NaCl 0.9%. The performance of the robot (accuracy and precision) to prepare bags, syringes and elastomeric pumps was evaluated with three placebo solutions (aqueous, foaming and viscous) using gravimetric controls. Microbiological controls were also performed. The pumps met the requirements set for volumes ranging from 5 to 100 mL. A total of 274 preparations was compounded. For the bags, the filling accuracy was within the limit of ±10% from 1 to 48 mL with aqueous solution, from 0.6 to 48 mL with foaming solution and from 5 to 48 mL with viscous solution. For all syringes and elastomeric pumps, it was within the limit of ±10%. The precision was validated for all preparations, except for bags and syringes prepared with 0.6 and 0.25 mL, respectively. The samples of surfaces and air complied with ISO 5 class environment. Among the 24 gloves tests performed, two presented microbiological growth. All Media fill tests were validated. The qualification procedure led us to exclude injections of any active principle volume strictly lower than 1 mL. The microbiological contamination of operators' gloves remains a critical point. Our operators will be made aware of the issue during the training period.


Assuntos
Antineoplásicos/síntese química , Composição de Medicamentos/métodos , Contaminação de Medicamentos/prevenção & controle , Robótica/métodos , Seringas , Antineoplásicos/administração & dosagem , Composição de Medicamentos/instrumentação , Composição de Medicamentos/normas , Humanos , Infusões Intravenosas/normas , Injeções/normas , Robótica/instrumentação , Robótica/normas , Espanha , Seringas/microbiologia , Seringas/normas
5.
J Med Syst ; 44(1): 4, 2019 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-31760504

RESUMO

The purpose of this paper is to develop an autonomous tracking algorithm based on adaptive fusion kinematics method, the autonomous laparoscope control algorithm and adaptive fusion kinematics method are proposed for semi-autonomous surgery, focus on solving the problems of autonomous laparoscope field of view control for surgical robot system. A novel autonomous tracking algorithm is proposed. To realize more robust tracking, an adaptive fusion kinematics method based on fuzzy logic is proposed, the method adaptive associates the kinematics information of surgical robot system and the laparoscope information. The proposed methods are implemented on the laparoscopic minimally invasive surgical robot system which is developed by our laboratory. Two experiments are carried out, the results indicate that the accurate autonomous field of view control is achieved with the addition of laparoscope information, laparoscopic motion frequency is reduced, the methods can avoid the laparoscope continuous motion and ensure the stability of field of view. The proposed methods improve the intelligence level of surgical robot system.


Assuntos
Algoritmos , Inteligência Artificial , Laparoscópios/normas , Robótica/normas , Simulação por Computador , Desenho de Equipamento , Humanos , Modelos Teóricos
6.
Eur J Radiol ; 119: 108659, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31520930

RESUMO

PURPOSE: To evaluate image quality (IQ) and radiation dose in cone-beam computed tomography (CBCT) of the ankle using a novel twin robotic X-ray system. METHOD: We examined 16 cadaveric ankles with standard-dose (FD) and low-dose (LD) protocols using the new system's CBCT mode. For comparison, we performed multi-slice CT imaging (MSCT) with a clinical protocol. Three radiologists assessed IQ, noise and artifacts in bone and soft tissue on a five-point Likert scale (1= poor IQ; strong noise or artifacts; 5= excellent IQ; minimal noise or artifacts). Volume CT dose indices (CTDIvol) were calculated for radiation dose comparison between CBCT and MSCT. RESULTS: Overall IQ was described as very good or excellent by reader 1/2/3 in 62.5/87.5/56.3% of LD, 87.5/87.5/81.3% of FD and 100/87.5/87.5% of MSCT studies. Readers agreed that IQ was better in MSCT than LD (R1/R2/R3; p ≤ 0.008), two also found advantages of MSCT over FD (R1/R3; p ≤ 0.034). Soft tissue noise and artifacts were stronger in FD (all p ≤ 0.002) and LD (all p ≤ 0.001). In bone, artifacts and noise were also more severe in LD (all p < 0.001) and FD (all p ≤ 0.003). CTDIvol for clinical MSCT scans without dose modulation (15.0 ± 0.0 mGy) were higher than for FD (5.3 ± 1.0 mGy) and LD studies (2.9 ± 0.6 mGy; both p < 0.001). CONCLUSIONS: Despite MSCT providing better overall IQ than the twin robotic X-ray system's CBCT mode, both cone-beam protocols offer very good IQ in most studies and are suitable for clinical ankle imaging. Standard-dose and especially low-dose CBCT studies deliver up to five times less radiation dose than MSCT imaging.


Assuntos
Articulação do Tornozelo/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/normas , Doses de Radiação , Robótica/normas , Artefatos , Cadáver , Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Desenho de Equipamento , Humanos , Imagens de Fantasmas , Robótica/métodos , Razão Sinal-Ruído , Tomógrafos Computadorizados/normas , Raios X
7.
Zhongguo Yi Liao Qi Xie Za Zhi ; 43(4): 266-269, 2019 Jul 30.
Artigo em Chinês | MEDLINE | ID: mdl-31460718

RESUMO

Mandible is an important bone of the head and neck. Mandibular defects not only affect patient's face, but also impede patient's daily functions, such as chewing, speech, and so on. Fibular transplantation for mandibular reconstruction is the common method, which requests high accuracy of bone positioning and posture adjustment. Therefore, a robotic system for mandibular reconstruction surgery with fibula flaps was designed to assist surgeons to hold and locate bones, and the model comparison experiments were conducted. The results showed that the robotic system can assist surgeons for mandibular reconstruction to improve quality of surgery.


Assuntos
Transplante Ósseo , Reconstrução Mandibular , Robótica , Cirurgia Assistida por Computador , Transplante Ósseo/métodos , Transplante Ósseo/normas , Fíbula/transplante , Humanos , Mandíbula/cirurgia , Reconstrução Mandibular/métodos , Robótica/normas
8.
J Endourol ; 33(5): 383-388, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30869541

RESUMO

Introduction: There is paucity of literature about the validation of the American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP®) surgical risk calculator for prediction of outcomes after robot-assisted radical cystectomy (RARC). We sought to evaluate the accuracy of the ACS NSQIP surgical risk calculator in the patients who underwent RARC at our institute. Methods: We retrospectively reviewed our prospectively maintained database for patients who underwent RARC between 2005 and 2017. Accuracy of the ACS NSQIP surgical risk calculator was assessed, by comparing the rate of actual complication events after surgery with the receiver operating characteristics curve analysis by calculating the fractional area under the curve (AUC) and the Brier score (BS). We utilized the code number 51595 and 51596 in the ACS NSQIP calculator for the patients undergoing radical cystectomy and reconstructed with the ileal conduit and neobladder, respectively. Results: A total of 462 patients were included in this study: 99 (22%) had diabetes, 302 (66%) had hypertension requiring medication, and 241 (52%) were classified as high American Society of Anesthesiologists (≥3) class. The actual observed rates of any complication and serious complications were 48% and 11%, vs 29% and 25% predicted by the ACS NSQIP, respectively. The actual mean length of hospital stay (10.6 ± 7.8 days) was longer compared with the predicted length (8.5 ± 1.6 days). AUC values were low and the BSs were high for any complication (AUC: 0.50 and BS: 0.29), serious complication (AUC: 0.53 and BS: 0.12), urinary tract infection (AUC: 0.61 and BS: 0.14), renal insufficiency (AUC: 0.64 and BS: 0.08), return to operation room (AUC: 0.58 and BS: 0.07), and early readmission (AUC: 0.55 and BS: 0.11, respectively). Conclusions: The ACS NSQIP calculator demonstrated low accuracy in predicting postoperative outcomes after RARC. These findings highlight the need for development of procedure- and technique-specific RARC calculators.


Assuntos
Cistectomia/normas , Técnicas de Apoio para a Decisão , Robótica/normas , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Melhoria de Qualidade , Curva ROC , Estudos Retrospectivos , Medição de Risco , Sensibilidade e Especificidade , Estados Unidos
9.
Surg Endosc ; 33(9): 3014-3025, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30426255

RESUMO

BACKGROUND: Roux-en-Y-gastric bypass (RYGB) and sleeve gastrectomy (SG) are commonly performed bariatric procedures that are associated with a significant learning curve. The effect of surgeon experience on perioperative outcomes and safety is established, but the effect of trainee participation remains unclear. The purpose of this study was to assess the impact of trainees on early perioperative safety of bariatric surgery. METHODS: Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program database for 2015 was used to identify non-revisional laparoscopic and robotic RYGB and SG procedures. Comparisons were made based on assistant level. Multivariable logistic and linear regression methodology was used to compare clinical outcomes. RESULTS: There were 35,354 laparoscopic RYGB, 2896 robotic RYGB, 79,717 laparoscopic SG, and 5449 robotic SG procedures examined. 21,257 (17%) and 11,322 (9%) of all procedures were performed with a resident or fellow, respectively. Fellow presence was independently associated with the development of complications for all procedure types except robotic SG when compared to non-trainee [odds ratio (OR) 1.31, 2.20, 1.28 for laparoscopic RYGB, robotic RYGB, and laparoscopic SG, respectively]. The most common events were urinary tract and superficial surgical site infections. This negative impact of fellow on overall complications was eliminated after accounting for operative duration. In laparoscopic SG, resident participation was associated with higher leak rate (OR 1.61), readmission (OR 1.18), re-intervention (OR 1.4), and complication rate (OR 1.32) compared to non-trainee, even after accounting for procedural duration. In robotic SG, there was no impact of trainee on outcomes. CONCLUSIONS: Although fellow training is associated with higher overall complication rate, there is no such impact on major safety benchmarks, including leak rate and re-operation. In contrast, the impact of resident trainees on SG outcomes is substantial. Operative involvement of trainees in bariatric surgery leads to different outcomes based on trainee level and should be judiciously considered during the programmatic design of bariatric educational curricula.


Assuntos
Cirurgia Bariátrica/educação , Educação de Pós-Graduação em Medicina/normas , Cirurgia Geral/educação , Laparoscopia/educação , Curva de Aprendizado , Obesidade Mórbida/cirurgia , Robótica/educação , Adulto , Cirurgia Bariátrica/normas , Feminino , Humanos , Laparoscopia/normas , Masculino , Estudos Retrospectivos , Robótica/normas
10.
JSLS ; 22(4)2018.
Artigo em Inglês | MEDLINE | ID: mdl-30524184

RESUMO

BACKGROUND AND OBJECTIVES: The uses of robotics in surgery were hypothesized as far back as 1967, but it took nearly 30 years and the nation's largest agency, the Department of Defense, in conjunction with innovative startups and established research agencies to complete the first fully functional multipurpose surgical robot. Currently, the most prominently available multipurpose robotic surgery system with US Food and Drug Administration approval is Intuitive Surgical Inc.'s da Vinci Surgical System, which is found in operating rooms across the globe. Although now ubiquitous for minimally invasive surgery, early surgical robot prototypes were specialty focused. Originally, multipurpose robotic systems were intended for long-distance trauma surgery in battlefield settings. While there were impressive feats of telesurgery, the marketable focus has veered from this goal. Initially developed through SRI International and Defense Advanced Research Projects Agency, surgical robotics reached private industry through two major competitors, who later merged. METHODS: A thorough search of PubMed, Clinical Key, EBSCO, Ovid, ProQuest, and industry manufacturers' websites yielded 62 relevant articles, of which 51 were evaluated in this review. CONCLUSION: We analyzed the literature and referred to primary sources by conducting interviews with present and historical leaders in the field to yield a detailed chronology of surgical robotics development. As minimally invasive robotic procedures are becoming the standard of care, it is crucial to comprehensively document their historical context and importance as an emerging and evolving discipline.


Assuntos
Procedimentos Cirúrgicos Minimamente Invasivos/história , Procedimentos Cirúrgicos Robóticos/história , Robótica/história , Telemedicina/história , Animais , História do Século XX , História do Século XXI , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/normas , Procedimentos Cirúrgicos Robóticos/normas , Robótica/normas , Padrão de Cuidado , Telemedicina/normas , Realidade Virtual
11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 1708-1712, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30440724

RESUMO

In this paper, we present the work achieved to define the robotic functionalities of interest for percutaneous procedures as performed in interventional radiology. Our contributions are twofold. First, a detailed task analysis is performed with workflow analysis of biopsies, one of the most frequent tasks, under three imaging modalities, namely CT, CBCT and MRI. Second, the functionalities of a robotic assistant are identified, and we analyze whether a single device can bring an added value during procedures in the three modalities while keeping the robotized workflow close to manual tasks, to minimize learning time and difficulty of use. Experimental analysis on CBCT is notably used to confirm the interest of the determined robotic functionalities.


Assuntos
Imageamento por Ressonância Magnética , Radiologia , Procedimentos Cirúrgicos Robóticos , Robótica , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Imageamento por Ressonância Magnética/instrumentação , Radiologia/instrumentação , Radiologia/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Robótica/instrumentação , Robótica/normas , Tomografia Computadorizada de Feixe Cônico Espiral/instrumentação , Fluxo de Trabalho
12.
Acta Neurochir (Wien) ; 160(12): 2489-2500, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30413938

RESUMO

BACKGROUND: Stereoelectroencephalography (SEEG) is an effective technique to help to locate and to delimit the epileptogenic area and/or to define relationships with functional cortical areas. We intend to describe the surgical technique and verify the accuracy, safety, and effectiveness of robot-assisted SEEG in a newly created SEEG program in a pediatric center. We focus on the technical difficulties encountered at the early stages of this program. METHODS: We prospectively collected SEEG indication, intraoperative events, accuracy calculated by fusion of postoperative CT with preoperative planning, complications, and usefulness of SEEG in terms of answering preimplantation hypothesis. RESULTS: Fourteen patients between the ages of 5 and 18 years old (mean 10 years) with drug-resistant epilepsy were operated on between April 2016 and April 2018. One hundred sixty-four electrodes were implanted in total. The median entry point localization error (EPLE) was 1.57 mm (1-2.25 mm) and the median target point localization error (TPLE) was 1.77 mm (1.2-2.6 mm). We recorded seven intraoperative technical issues. Two patients suffered complications: meningitis without demonstrated germ in one patient and a right frontal hematoma in the other. In all cases, the SEEG was useful for the therapeutic decision-making. CONCLUSION: SEEG has been useful for decision-making in all our pediatric patients. The robotic arm is an accurate tool for the insertion of the deep electrodes. Nevertheless, it is an invasive technique not risk-free and many problems can appear at the beginning of a robotic arm-assisted SEEG program that must be taken into account beforehand.


Assuntos
Epilepsia Resistente a Medicamentos/cirurgia , Eletroencefalografia/métodos , Complicações Pós-Operatórias/epidemiologia , Robótica/métodos , Técnicas Estereotáxicas/efeitos adversos , Adolescente , Criança , Pré-Escolar , Tomada de Decisão Clínica , Epilepsia Resistente a Medicamentos/diagnóstico , Eletrodos Implantados/efeitos adversos , Eletrodos Implantados/normas , Eletroencefalografia/efeitos adversos , Eletroencefalografia/instrumentação , Eletroencefalografia/normas , Feminino , Humanos , Masculino , Robótica/instrumentação , Robótica/normas , Técnicas Estereotáxicas/instrumentação , Técnicas Estereotáxicas/normas
13.
Urology ; 107: 120-125, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28579070

RESUMO

OBJECTIVE: To investigate the cognitive and physical workload experienced by each operating room team member for different types of urologic procedures. METHODS: Surgeons, anesthesiologists, surgical fellows, bedside assistants, circulating nurses, and scrub nurses completed the National Aeronautics and Space Administration Task Load Index questionnaire for various urologic robot-assisted surgery procedures. A total of 338 questionnaires from 55 unique individuals were collected. Workload differences by role, type of procedure, and surgery duration were analyzed using analysis of variance for each of the 6 domains of the National Aeronautics and Space Administration Task Load Index. The effects of trainees' participation on their perceived workload and the workloads of the lead surgeon and bedside assistant were analyzed with correlation. RESULTS: The role of the surgical team was significant for all the scales of workload, and there was a main effect type of surgery on temporal demand and frustration. Frustration was higher for prostatectomy in comparison to cystectomy for the trainee surgeon. On the other hand, it was lower for the anesthesiologist, bedside assistant, and the circulating nurse. There was no effect of procedural complexity on workload. Regardless of surgical complexity, the trainees performed approximately 40% of the procedure without significantly impacting their perceived workload. CONCLUSION: This study provides an analysis of variations and contributors to workload parameters and serves as a platform to optimize team members' workload during robot-assisted surgery.


Assuntos
Percepção , Melhoria de Qualidade , Robótica/normas , Cirurgiões/psicologia , Procedimentos Cirúrgicos Urológicos/psicologia , Carga de Trabalho/psicologia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Inquéritos e Questionários , Análise e Desempenho de Tarefas , Procedimentos Cirúrgicos Urológicos/normas
14.
Mil Med ; 182(S1): 316-321, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28291492

RESUMO

This study aimed to evaluate the capability of performing telesurgery via radio transmission for military arenas where wired internet connections may not be practical. Most existing robotic surgery systems are too large to effectively deploy with first responders. The miniature surgical platform in this study consists of a multifunctional robot suite that can fit easily into a briefcase. METHODS: The focus of this study is to explore the implications of radio control of the robot. The hypothesis is that an in vivo robot and its control boards can be controlled using off-the-shelf wireless components. An experiment was designed with off-the-shelf wireless components to test the capability of our newest generation of miniature surgical robot to become battery-operated and wireless. RESULTS: Wireless transmission of control signals has provided proof of concept and has exposed areas of the software that can be built upon to improve responsiveness. Wireless transmission of the video feed can be adequately performed with basic off-the-shelf components.


Assuntos
Competência Clínica/normas , Robótica/métodos , Cirurgiões/normas , Cirurgia Assistida por Computador/normas , Telemedicina/métodos , Desenho de Equipamento/normas , Humanos , Robótica/normas , Cirurgia Assistida por Computador/métodos , Telemedicina/normas , Guerra
15.
Phys Med Biol ; 62(6): 2417-2426, 2017 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-28169225

RESUMO

Intraoperative assessment of lead localization has become a standard procedure during deep brain stimulation surgery in many centers, allowing immediate verification of targeting accuracy and, if necessary, adjustment of the trajectory. The most suitable imaging modality to determine lead positioning, however, remains controversially discussed. Current approaches entail the implementation of computed tomography and magnetic resonance imaging. In the present study, we adopted the technique of intensity-based 2D 3D registration that is commonly employed in stereotactic radiotherapy and spinal surgery. For this purpose, intraoperatively acquired 2D x-ray images were fused with preoperative 3D computed tomography (CT) data to verify lead placement during stereotactic robot assisted surgery. Accuracy of lead localization determined from 2D 3D registration was compared to conventional 3D 3D registration in a subsequent patient study. The mean Euclidian distance of lead coordinates estimated from intensity-based 2D 3D registration versus flat-panel detector CT 3D 3D registration was 0.7 mm ± 0.2 mm. Maximum values of these distances amounted to 1.2 mm. To further investigate 2D 3D registration a simulation study was conducted, challenging two observers to visually assess artificially generated 2D 3D registration errors. 95% of deviation simulations, which were visually assessed as sufficient, had a registration error below 0.7 mm. In conclusion, 2D 3D intensity-based registration revealed high accuracy and reliability during robot guided stereotactic neurosurgery and holds great potential as a low dose, cost effective means for intraoperative lead localization.


Assuntos
Estimulação Encefálica Profunda/métodos , Robótica/métodos , Técnicas Estereotáxicas/normas , Estimulação Encefálica Profunda/instrumentação , Estimulação Encefálica Profunda/normas , Humanos , Imageamento Tridimensional/métodos , Imageamento Tridimensional/normas , Robótica/normas , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas
16.
Technol Health Care ; 24(6): 873-887, 2016 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-27434282

RESUMO

OBJECTIVES: The following study proposes and tests an integrated methodology involving Health Technology Assessment (HTA) and Failure Modes, Effects and Criticality Analysis (FMECA) for the assessment of specific aspects related to robotic surgery involving safety, process and technology. METHODS: The integrated methodology consists of the application of specific techniques coming from the HTA joined to the aid of the most typical models from reliability engineering such as FMEA/FMECA. The study has also included in-site data collection and interviews to medical personnel. RESULTS: The total number of robotic procedures included in the analysis was 44: 28 for urology and 16 for general surgery. The main outcomes refer to the comparative evaluation between robotic, laparoscopic and open surgery. Risk analysis and mitigation interventions come from FMECA application. CONCLUSIONS: The small sample size available for the study represents an important bias, especially for the clinical outcomes reliability. Despite this, the study seems to confirm the better trend for robotics' surgical times with comparison to the open technique as well as confirming the robotics' clinical benefits in urology. More complex situation is observed for general surgery, where robotics' clinical benefits directly measured are the lowest blood transfusion rate.


Assuntos
Desenho de Equipamento/normas , Cirurgia Geral/instrumentação , Cirurgia Geral/métodos , Laparoscopia/instrumentação , Robótica/instrumentação , Robótica/normas , Procedimentos Cirúrgicos Urológicos/instrumentação , Procedimentos Cirúrgicos Urológicos/métodos , Humanos , Laparoscopia/métodos , Reprodutibilidade dos Testes , Robótica/métodos
17.
J Robot Surg ; 10(4): 289-296, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27334771

RESUMO

To investigate whether the learning curve of robotic surgery simulator training depends on the probands' characteristics, such as age and prior experience, we conducted a study of six distinct proband groups, using the da Vinci Skills Simulator: experienced urological robotic surgeons, surgeons with experience as da Vinci tableside assistants, urological surgeons with laparoscopic experience, urological surgeons without laparoscopic experience, and complete novices aged 25 and younger and 40 and older. The results showed that all experienced robotic surgeons reached expert level (>90 %, as defined previously in the literature) within the first three repetitions and remained on a high level of performance. All other groups performed worse. Tableside assistants, laparoscopically experienced surgeons, and younger novices showed a better performance in all exercises than surgeons without laparoscopic experience and older novices. A linear mixed-effects model analysis demonstrated no significant difference in learning curves between proband groups in all exercises except the RW1 exercise for the younger proband group. In summary, we found that performance in robotic surgery, measured by performance scores in three virtual simulator modules using the EndoWrist techniques, was dependent on age and prior experience with robotic and laparoscopic surgery. However, and most importantly, the learning curve was not significantly affected by these factors. This suggests that the da Vinci Skills Simulator™ is a useful practice tool for everyone learning or performing robotic surgery, and that early selection of talented surgeons is neither possible nor necessary.


Assuntos
Competência Clínica/normas , Procedimentos Cirúrgicos Robóticos/educação , Robótica/educação , Treinamento por Simulação/métodos , Cirurgiões/educação , Urologistas/normas , Adulto , Idoso , Humanos , Laparoscopia/educação , Laparoscopia/normas , Curva de Aprendizado , Pessoa de Meia-Idade , Seleção de Pessoal , Assistentes Médicos/normas , Procedimentos Cirúrgicos Robóticos/normas , Robótica/normas , Cirurgiões/normas
18.
J Minim Invasive Gynecol ; 23(4): 633-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27013278

RESUMO

The Robotic Objective Structured Assessment of Technical Skills (R-OSATS) is a previously validated assessment tool that is used to assess 5 standardized inanimate robotic surgery drills. R-OSATS is used to evaluate performance on surgical drills, with scores of 0 to 20 for each drill. Our objective was to establish the minimum threshold score that denotes competence on these drills. Thus, we performed a standard setting study using data from surgeons and trainees in 8 academic medical centers. Cutoff scores for the minimal level of competence using R-OSATS were established using 2 techniques: the modified Angoff and the contrasting groups methods. For the modified Angoff method, 8 content experts met and, in an iterative process, derived the scores that a minimally competent trainee should receive. After 2 iterative rounds of scoring and discussion with the modified Angoff method, we established a minimum competence score per drill with high agreement (rWG range, 0.92-0.98). There was unanimous consensus that a trainee needs to achieve competence on each independent drill. A second method, the contrasting groups method, was used to verify our results. In this method, we compared R-OSATS scores from "inexperienced" (34 postgraduate year 1 and 2 trainees) with "experienced" (22 faculty and fellow) robotic surgeons. The distributions of scores from both groups were plotted, and a cutoff score for each drill was determined from the intersection of the 2 curves. Using this method, the minimum score for competence would be 14 per drill, which is slightly more stringent but confirms the results obtained from the modified Angoff approach. In conclusion, using 2 well-described standard setting techniques, we have established minimum benchmarks designating trainee competence for 5 dry lab robotic surgery drills.


Assuntos
Benchmarking/normas , Competência Clínica/normas , Procedimentos Cirúrgicos Robóticos/normas , Cirurgiões/normas , Medicina Baseada em Evidências , Estudos de Viabilidade , Humanos , Robótica/normas
19.
J Oncol Pharm Pract ; 22(2): 195-204, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25549919

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the contamination rate of media-fill products either prepared automated with a robotic system (APOTECAchemo™) or prepared manually at cytotoxic workbenches in the same cleanroom environment and by experienced operators. Media fills were completed by microbiological environmental control in the critical zones and used to validate the cleaning and disinfection procedures of the robotic system. METHODS: The aseptic preparation of patient individual ready-to-use injection solutions was simulated by using double concentrated tryptic soy broth as growth medium, water for injection and plastic syringes as primary packaging materials. Media fills were either prepared automated (500 units) in the robot or manually (500 units) in cytotoxic workbenches in the same cleanroom over a period of 18 working days. The test solutions were incubated at room temperature (22℃) over 4 weeks. Products were visually inspected for turbidity after a 2-week and 4-week period. Following incubation, growth promotion tests were performed with Staphylococcus epidermidis. During the media-fill procedures, passive air monitoring was performed with settle plates and surface monitoring with contact plates on predefined locations as well as fingerprints. The plates got incubated for 5-7 days at room temperature, followed by 2-3 days at 30-35℃ and the colony forming units (cfu) counted after both periods. The robot was cleaned and disinfected according to the established standard operating procedure on two working days prior to the media-fill session, while on six other working days only six critical components were sanitized at the end of the media-fill sessions. Every day UV irradiation was operated for 4 h after finishing work. RESULTS: None of the 1000 media-fill products prepared in the two different settings showed turbidity after the incubation period thereby indicating no contamination with microorganisms. All products remained uniform, clear, and light-amber solutions. In addition, the reliability of the nutrient medium and the process was demonstrated by positive growth promotion tests with S. epidermidis. During automated preparation the recommended limits < 1 cfu per settle/contact plate set for cleanroom Grade A zones were not succeeded in the carousel and working area, but in the loading area of the robot. During manual preparation, the number of cfus detected on settle/contact plates inside the workbenches lay far below the limits. The number of cfus detected on fingertips succeeded several times the limit during manual preparation but not during automated preparation. There was no difference in the microbial contamination rate depending on the extent of cleaning and disinfection of the robot. CONCLUSION: Extensive media-fill tests simulating manual and automated preparation of ready-to-use cytotoxic injection solutions revealed the same level of sterility for both procedures. The results of supplemental environmental controls confirmed that the aseptic procedures are well controlled. As there was no difference in the microbial contamination rates of the media preparations depending on the extent of cleaning and disinfection of the robot, the results were used to adapt the respective standard operating procedures.


Assuntos
Assepsia/métodos , Contaminação de Medicamentos/prevenção & controle , Soluções Farmacêuticas , Robótica/métodos , Seringas , Tecnologia Farmacêutica/métodos , Assepsia/normas , Soluções Farmacêuticas/normas , Robótica/normas , Seringas/microbiologia , Seringas/normas , Tecnologia Farmacêutica/normas
20.
J Appl Clin Med Phys ; 16(5): 35-45, 2015 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699314

RESUMO

The purpose of this study was to investigate the magnitude and dosimetric relevance of translational and rotational shifts on IGRT prostate volumetric-modulated arc therapy (VMAT) using Protura six degrees of freedom (DOF) Robotic Patient Positioning System. Patients with cT3aN0M0 prostate cancer, treated with VMAT simultaneous integrated boost (VMAT-SIB), were enrolled. PTV2 was obtained adding 0.7 cm margin to seminal vesicles base (CTV2), while PTV1 adding to prostate (CTV1) 0.7 cm margin in all directions, except 1.2 cm, as caudal margin. A daily CBCT was acquired before dose delivery. The translational and rotational displacements were corrected through Protura Robotic Couch, collected and applied to the simulation CT to obtain a translated CT (tCT) and a rototranslated CT (rtCT) on which we recalculated the initial treatment plan (TP). We analyzed the correlation between dosimetric coverage, organs at risk (OAR) sparing, and translational or rotational displacements. The dosimetric impact of a rototranslational correction was calculated. From October 2012 to September 2013, a total of 263 CBCT scans from 12 patients were collected. Translational shifts were < 5 mm in 81% of patients and the rotational shifts were < 2° in 93% of patient scans. The dosimetric analysis was performed on 172 CBCT scans and calculating 344 VMAT-TP. Two significant linear correlations were observed between yaw and the V20 femoral heads and between pitch rotation and V50 rectum (p < 0.001); rototranslational correction seems to impact more on PTV2 than on PTV1, especially when margins are reduced. Rotational errors are of dosimetric significance in sparing OAR and in target coverage. This is relevant for femoral heads and rectum because of major distance from isocenter, and for seminal vesicles because of irregular shape. No correlation was observed between translational and rotational errors. A study considering the intrafractional error and the deformable registration is ongoing.


Assuntos
Movimento/fisiologia , Posicionamento do Paciente/normas , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Radioterapia de Intensidade Modulada/normas , Robótica/normas , Leitos , Humanos , Masculino , Posicionamento do Paciente/métodos , Dosagem Radioterapêutica , Robótica/métodos , Rotação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA