1.
Anal Sci ; 35(11): 1269-1274, 2019 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-31378774

RESUMO

In HPLC analyses of soluble dietary fiber, desalting processes using open, mixed-bed ion-exchange columns are time-consuming and labor-intensive. We developed and validated a simple desalting method using tandem cation/anion exchange SPE cartridges. We found that combining Bond Elut Jr SCX (upstream) and Bond Elut PSA (downstream) cartridges provided adequate desalting of test solutions. The developed method was then validated in an inter-laboratory study. Five test samples were prepared by mixing food matrixes with purified soluble dietary fiber and treated to generate solutions to test the desalting process. These solutions were then analyzed by eight different laboratories. The results demonstrated that the developed method is simple and reliable for desalting samples containing 140 to 945 mg/100 mL of soluble dietary fiber in preparation for HPLC analysis of soluble dietary fiber.


Assuntos
Métodos Analíticos de Preparação de Amostras/métodos , Fibras na Dieta/análise , Laboratórios , Sais/isolamento & purificação , Extração em Fase Sólida/métodos , Métodos Analíticos de Preparação de Amostras/instrumentação , Cromatografia Líquida de Alta Pressão , Troca Iônica , Reprodutibilidade dos Testes , Sais/química , Extração em Fase Sólida/instrumentação , Solubilidade
2.
Chemosphere ; 219: 28-35, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30528970

RESUMO

Typical Chinese source water has high content of low molecular weight and aromatic protein-like organic matter which is difficult to remove and poses a great challenge to conventional coagulation/flocculation. To investigate coagulation performance of this typical water, this research focused on organic matter removal characteristics and the associated disinfection byproducts formation potentials (DBPFPs) during the coagulation process by titanium salts compared with traditional aluminum and ferric salts. Results showed that based on the dissolved organic matter (DOM) removal, the optimal coagulant dosages of AlCl3, FeCl3 and TiCl4 were 0.5 mM and the optimal initial pH values were 8, indicating that the DOM in the typical Chinese water could be effectively removed through sweeping and adsorption by metal hydroxides rather than the complexation and charge neutralization effect under acidic conditions. Compared these three coagulants, the highest ultra violet absorbance at 254 nm removal rate of 72.9% was achieved by TiCl4. The three-dimensional excitation emission matrix results showed that the removal ability of humic acids by AlCl3 was poorer than FeCl3 and TiCl4. The removal rate of low molecular weight components (1600 Da) by TiCl4 was 20% higher than using AlCl3 and 14% higher than FeCl3. Comparing with AlCl3 and FeCl3, TiCl4 had a better performance on the control of DBPFPs, especially for chloroform and dichloroacetic acid, due to its higher removal ability of aromatic organics. The trihalomethane formation potentials removal rate by TiCl4 was three times higher than that by AlCl3 and twice by FeCl3, by which could be inferred that titanium salts achieved better removal of low molecular weight organic matter than aluminum and ferric salts.


Assuntos
Sais/isolamento & purificação , Poluentes Químicos da Água/isolamento & purificação , Purificação da Água/métodos , Alumínio/química , China , Desinfecção , Compostos Férricos/química , Floculação , Substâncias Húmicas/análise , Titânio/química , Poluentes Químicos da Água/análise
3.
Nat Protoc ; 13(12): 2964-2990, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30446747

RESUMO

Cross-linking mass spectrometry (XL-MS) has received considerable interest, owing to its potential to investigate protein-protein interactions (PPIs) in an unbiased fashion in complex protein mixtures. Recent developments have enabled the detection of thousands of PPIs from a single experiment. A unique strength of XL-MS, in comparison with other methods for determining PPIs, is that it provides direct spatial information for the detected interactions. This is accomplished by the use of bifunctional cross-linking molecules that link two amino acids in close proximity with a covalent bond. Upon proteolytic digestion, this results in two newly linked peptides, which are identifiable by MS. XL-MS has received the required boost to tackle more-complex samples with recent advances in cross-linking chemistry with MS-cleavable or reporter-based cross-linkers and faster, more sensitive and more versatile MS platforms. This protocol provides a detailed description of our optimized conditions for a full-proteome native protein preparation followed by cross-linking using the gas-phase cleavable cross-linking reagent disuccinimidyl sulfoxide (DSSO). Following cross-linking, we demonstrate extensive sample fractionation and substantially simplified data analysis with XlinkX in Proteome Discoverer, as well as subsequent protein structure investigations with DisVis and HADDOCK. This protocol produces data of high confidence and can be performed within ~10 d, including structural investigations.


Assuntos
Reagentes de Ligações Cruzadas/química , Peptídeos/análise , Proteínas/química , Proteômica/métodos , Espectrometria de Massas em Tandem/métodos , Animais , Linhagem Celular , Cromatografia Líquida/métodos , Humanos , Modelos Moleculares , Proteólise , Proteoma/química , Sais/isolamento & purificação
4.
Bioelectrochemistry ; 121: 176-184, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29459302

RESUMO

Microbial desalination cell (MDC) is a bioelectrochemical system capable of oxidizing organics, generating electricity, while reducing the salinity content of brine streams. As it is designed, anion and cation exchange membranes play an important role on the selective removal of ions from the desalination chamber. In this work, sulfonated sodium (Na+) poly(ether ether ketone) (SPEEK) cation exchange membranes (CEM) were tested in combination with quaternary ammonium chloride poly(2,6-dimethyl 1,4-phenylene oxide) (QAPPO) anion exchange membrane (AEM). Non-patterned and patterned (varying topographical features) CEMs were investigated and assessed in this work. The results were contrasted against a commercially available CEM. This work used real seawater from the Pacific Ocean in the desalination chamber. The results displayed a high desalination rate and power generation for all the membranes, with a maximum of 78.6±2.0% in salinity reduction and 235±7mWm-2 in power generation for the MDCs with the SPEEK CEM. Desalination rate and power generation achieved are higher with synthesized SPEEK membranes when compared with an available commercial CEM. An optimized combination of these types of membranes substantially improves the performances of MDC, making the system more suitable for real applications.


Assuntos
Fontes de Energia Bioelétrica/microbiologia , Cetonas/química , Polietilenoglicóis/química , Salinidade , Sais/isolamento & purificação , Água do Mar/análise , Sulfonas/química , Benzofenonas , Resinas de Troca de Cátion/química , Eletricidade , Eletrodos , Desenho de Equipamento , Membranas Artificiais , Polímeros
5.
Anal Chem ; 89(11): 5784-5792, 2017 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-28530406

RESUMO

Detergents and salts are widely used in lysis buffers to enhance protein extraction from biological samples, facilitating in-depth proteomic analysis. However, these detergents and salt additives must be efficiently removed from the digested samples prior to LC-MS/MS analysis to obtain high-quality mass spectra. Although filter-aided sample preparation (FASP), acetone precipitation (AP), followed by in-solution digestion, and strong cation exchange-based centrifugal proteomic reactors (CPRs) are commonly used for proteomic sample processing, little is known about their efficiencies at removing detergents and salt additives. In this study, we (i) developed an integrative workflow for the quantification of small molecular additives in proteomic samples, developing a multiple reaction monitoring (MRM)-based LC-MS approach for the quantification of six additives (i.e., Tris, urea, CHAPS, SDS, SDC, and Triton X-100) and (ii) systematically evaluated the relationships between the level of additive remaining in samples following sample processing and the number of peptides/proteins identified by mass spectrometry. Although FASP outperformed the other two methods, the results were complementary in terms of peptide/protein identification, as well as the GRAVY index and amino acid distributions. This is the first systematic and quantitative study of the effect of detergents and salt additives on protein identification. This MRM-based approach can be used for an unbiased evaluation of the performance of new sample preparation methods. Data are available via ProteomeXchange under identifier PXD005405.


Assuntos
Proteômica/métodos , Manejo de Espécimes/métodos , Soluções Tampão , Cromatografia Líquida , Detergentes/isolamento & purificação , Peptídeos/análise , Proteínas/análise , Sais/isolamento & purificação , Espectrometria de Massas em Tandem
6.
J Oleo Sci ; 66(2): 123-131, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-28100882

RESUMO

A fractionation methodology of fat, oil and grease (FOG) deposits was developed based on the insolubility of fatty acid salts in dichloromethane (DCM) and the relatively high solubility of fatty acids and triglycerides in DCM. Using this method, coupled with spectral analysis, it was shown that fatty acids rather than fatty acid salts were the predominant species in FOG deposits obtained from three metropolitan locations in the United States and that fatty acid triglycerides were either not detected or were present in very small concentrations. This solubility-based fractionation approach also revealed the presence of nitrogen-containing compounds that had not been previously detected in FOG deposits including peptides and (or) proteins. The comparison of the ratios of stearic acid salts to stearic acid versus the ratio of palmitic acid salts to palmitic acid in FOG deposits may indicate that the initial step in FOG deposit formation is the preferential precipitation of stearic acid salts.


Assuntos
Gorduras/química , Ácidos Graxos/análise , Ácidos Graxos/química , Óleos/química , Esgotos/química , Ácidos Graxos/isolamento & purificação , Sais/análise , Sais/química , Sais/isolamento & purificação , Solubilidade
7.
Artigo em Inglês | MEDLINE | ID: mdl-27288932

RESUMO

The wide variety and low abundance of peptides in tissue brought great difficulties to the separation and identification of peptides, which is not in favor of the development of peptidomics. RP-HPLC, which could purify small molecules based on their hydrophobicity, has been widely used in the separation and enrichment of peptide due to its fast, good reproducibility and high resolution. However, RP-HPLC requires the instrument and expensive C18 column and its sample capacity is also limited. Recently, graphene oxide has been applied to the adsorption of amino acids. However, the enrichment efficiency and selectivity of graphene oxide for peptides remain unclear. In this study, the adsorption efficiency and selectivity of graphene oxide and RP-C18 matrix were compared on trypsinized α-actin and also on tissue extracts from pituitary gland and hippocampus. For α-actin, there exhibit similar elution peaks for total trypsinized products and those adsorpted by GO and C18 matrix. But peptides adsorbed by GO showed the higher hydrophilic peaks than which adsorbed by C18 matrix. The resulted RP-HPLC profile showed that most of peptides enriched by graphene oxide were eluted at low concentration of organic solvent, while peptides adsorbed by RP-C18 matrix were mostly eluted at relatively high concentration. Moreover, mass spectrometry analysis suggested that, in pituitary sample, there were 495 peptides enriched by graphene oxide, 447 peptides enriched by RP-C18 matrix while in hippocampus sample 333 and 243 peptides respectively. The GRAVY value analysis suggested that the graphene oxide has a stronger adsorption for highly hydrophilic peptides compared to the RP-C18 matrix. Furthermore, the combination of these two methods could notably increase the number of identification peptides but also the number of predicted protein precursors. Our study provided a new thought to the role of graphene oxide during the enrichment of peptides from tissue which should be useful for peptidomics study.


Assuntos
Grafite/química , Peptídeos/isolamento & purificação , Proteínas/isolamento & purificação , Extração em Fase Sólida/métodos , Actinas/química , Actinas/isolamento & purificação , Adsorção , Sequência de Aminoácidos , Animais , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Hipocampo/química , Interações Hidrofóbicas e Hidrofílicas , Masculino , Camundongos Endogâmicos C57BL , Óxidos/química , Peptídeos/química , Hipófise/química , Proteínas/química , Proteômica , Coelhos , Sais/química , Sais/isolamento & purificação
8.
Sci Rep ; 5: 14530, 2015 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-26416014

RESUMO

Managing the wastewater discharged from oil and shale gas fields is a big challenge, because this kind of wastewater is normally polluted by high contents of both oils and salts. Conventional pressure-driven membranes experience little success for treating this wastewater because of either severe membrane fouling or incapability of desalination. In this study, we designed a new nanocomposite forward osmosis (FO) membrane for accomplishing simultaneous oil/water separation and desalination. This nanocomposite FO membrane is composed of an oil-repelling and salt-rejecting hydrogel selective layer on top of a graphene oxide (GO) nanosheets infused polymeric support layer. The hydrogel selective layer demonstrates strong underwater oleophobicity that leads to superior anti-fouling capability under various oil/water emulsions, and the infused GO in support layer can significantly mitigate internal concentration polarization (ICP) through reducing FO membrane structural parameter by as much as 20%. Compared with commercial FO membrane, this new FO membrane demonstrates more than three times higher water flux, higher removals for oil and salts (>99.9% for oil and >99.7% for multivalent ions) and significantly lower fouling tendency when investigated with simulated shale gas wastewater. These combined merits will endorse this new FO membrane with wide applications in treating highly saline and oily wastewaters.


Assuntos
Óleos Industriais/análise , Membranas Artificiais , Nanocompostos/química , Sais/isolamento & purificação , Águas Residuárias/química , Purificação da Água/instrumentação , Emulsões , Grafite/química , Humanos , Fraturamento Hidráulico , Hidrogéis/química , Cinética , Osmose , Óxidos , Salinidade , Purificação da Água/métodos
9.
Anal Chem ; 87(19): 9745-51, 2015 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-26312607

RESUMO

Sensitive detection of biomolecules in small-volume samples by mass spectrometry is, in many cases, challenging because of the use of buffers to maintain the biological activities of proteins and cells. Here, we report a highly effective desalting method for picoliter samples. It was based on the spontaneous separation of biomolecules from salts during crystallization of the salts. After desalting, the biomolecules were deposited in the tip of the quartz pipet because of the evaporation of the solvent. Subsequent detection of the separated biomolecules was achieved using solvent assisted electric field induced desorption/ionization (SAEFIDI) coupled with mass spectrometry. It allowed for direct desorption/ionization of the biomolecules in situ from the tip of the pipet. The organic component in the assistant solvent inhibited the desorption/ionization of salts, thus assured successful detection of biomolecules. Proteins and peptides down to 50 amol were successfully detected using our method even if there were 3 × 10(5) folds more amount of salts in the sample. The concentration and ion species of the salts had little influence on the detection results.


Assuntos
Peptídeos/análise , Proteínas/análise , Sais/isolamento & purificação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Soluções Tampão , Cristalização/instrumentação , Cristalização/métodos , Desenho de Equipamento , Tamanho da Amostra , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação
10.
Huan Jing Ke Xue ; 33(4): 1216-20, 2012 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-22720568

RESUMO

Desalted water, with strong corrosion characteristics, would possibly lead to serious "red water" when transmitted and distributed in existing municipal water distribution network. The main reason for red water phenomenon is iron release in water pipes. In order to study the methods of controlling iron release in existing drinking water distribution pipe, tubercle analysis of steel pipe and cast iron pipe, which have served the distribution system for 30-40 years, was carried out, the main construction materials were Fe3O4 and FeOOH; and immersion experiments were carried in more corrosive pipes. Through changing mixing volume of tap water and desalted water, pH, alkalinity, chloride and sulfate, the influence of different water quality indexes on iron release were mainly analyzed. Meanwhile, based on controlling iron content, water quality conditions were established to meet with the safety distribution of desalted water: volume ratio of potable water and desalted water should be higher than or equal to 2, pH was higher than 7.6, alkalinity was higher than 200 mg x L(-1).


Assuntos
Íons/análise , Sais/isolamento & purificação , Água do Mar/química , Purificação da Água/métodos , Abastecimento de Água , Água Doce/química , Abastecimento de Água/normas
11.
J Mass Spectrom ; 45(1): 104-11, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19927305

RESUMO

Peptide samples derived from enzymatic in-gel digestion of proteins resolved by gel electrophoresis often contain high amount of salts originating from reaction and separation buffers. Different methods are used for desalting prior to matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS), e.g. reversed-phase pipette tip purification, on-target washing, adding co-matrices, etc. As a suitable matrix for MALDI MS of peptides, alpha-cyano-4-hydroxycinnamic acid (CHCA) is frequently used. Crystalline CHCA shows the ability to bind peptides on its surface and because it is almost insoluble in acidic water solutions, the on-target washing of peptide samples can significantly improve MALDI MS signals. Although the common on-target washing represents a simple, cheap and fast procedure, only a small portion of the available peptide solution is efficiently used for the subsequent MS analysis. The present approach is a combination of the on-target washing principle carried out in a narrow-end pipette tip (e.g. GELoader tip) and preconcentration of peptides from acidified solution by passing it through small CHCA crystals captured inside the tip on a glass microfiber frit. The results of MALDI MS analysis using CHCA-tip peptide preconcentration are comparable with the use of homemade POROS R2 pipette tip microcolumns. Advantages and limitations of this approach are discussed.


Assuntos
Fracionamento Químico/métodos , Ácidos Cumáricos/química , Peptídeos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Peptídeos/química , Peptídeos/isolamento & purificação , Sais/química , Sais/isolamento & purificação , Espectrometria de Massas em Tandem/métodos
12.
Waste Manag ; 28(7): 1159-67, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-17714929

RESUMO

This work provides a method to help recover nickel, cobalt metals and some of their salts having market value from spent nickel-metal hydride batteries (SNiB). The methodology used benefits the solubility of the battery electrode materials in sulfuric or hydrochloric acids. The results obtained showed that sulfuric acid was slightly less powerful in leaching SNiB compared to HCl acid. Despite that, sulfuric acid was extremely applied on economic basis. The highest level of solubility attained 93.5% using 3N sulfuric acid at 90 degrees C for 3h. The addition of hydrogen peroxide to the reacting acid solution improved the level of solubility and enhanced the process in a shorter time. The maximum recovery of nickel and cobalt metals was 99.9% and 99.4%, respectively. Results were explained in the light of a model assuming that solubility was a first order reaction. It involved a multi-step sequence, the first step of which was the rate determining step of the overall solubility. Nickel salts such as hydroxide, chloride, hexamminenickel chloride, hexamminenickel nitrate, oxalate and nickel oleate were prepared. With cobalt, basic carbonate, chloride, nitrate, citrate, oleate and acetate salts were prepared from cobalt hydroxide Cost estimates showed that the prices of the end products were nearly 30% lower compared to the prices of the same chemicals prepared from primary resources.


Assuntos
Fontes de Energia Elétrica , Metais Pesados/química , Metais Pesados/isolamento & purificação , Sais/química , Sais/isolamento & purificação , Cobalto/química , Cobalto/isolamento & purificação , Conservação dos Recursos Naturais , Eletrônica , Cinética , Níquel/química , Níquel/isolamento & purificação , Oxirredução , Eliminação de Resíduos/métodos , Solubilidade
13.
Environ Geochem Health ; 29(4): 331-6, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17492478

RESUMO

This study may be the first investigation to be performed into the potential benefits of recycling industrial waste in controlling contaminants in leachate. Batch reactors were used to evaluate the efficacy of waste steel scrap and converter slag to treat mixed contaminants using mimic leachate solution. The waste steel scrap was prepared through pre-treatment by an acid-washed step, which retained both zero-valent iron site and iron oxide site. Extensive trichloroethene (TCE) removal (95%) occurred by acid-washed steel scrap within 48 h. In addition, dehalogenation (Cl(-) production) was observed to be above 7.5% of the added TCE on a molar basis for 48 h. The waste steel scrap also removed tetrachloroethylene (PCE) through the dehalogenation process although to a lesser extent than TCE. Heavy metals (Cr, Mn, Cu, Zn, As, Cd, and Pb) were extensively removed by both acid-washed steel scrap and converter slag through the adsorption process. Among salt ions (NH (4)(+) , NO (3)(-) , and PO (4)(3-) ), PO (4)(3-) was removed by both waste steel scrap (100% within 8 h) and converter slag (100% within 20 min), whereas NO (3)(-) and NH (4)(+ ) were removed by waste steel scrap (100% within 7 days) and converter slag (up to 50% within 4 days) respectively. This work suggests that permeable reactive barriers (PRBs) with waste steel scrap and converter slag might be an effective approach to intercepting mixed contaminants in leachate from landfill.


Assuntos
Recuperação e Remediação Ambiental , Resíduos Industriais , Aço , Poluentes Químicos da Água/química , Conservação dos Recursos Naturais , Metais Pesados/isolamento & purificação , Sais/isolamento & purificação , Soluções , Tricloroetileno/isolamento & purificação
14.
Anal Chem ; 79(1): 71-8, 2007 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-17194123

RESUMO

A mini ball mill (MBM) solvent-free matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) method allows for the analysis of bacteriorhodopsin (BR), an integral membrane protein that previously presented special analytical problems. For well-defined signals in the molecular ion region of the analytes, a desalting procedure of the MBM sample directly on the MALDI target plate was used to reduce adduction by sodium and other cations that are normally attendant with hydrophobic peptides and proteins as a result of the sample preparation procedure. Mass analysis of the intact hydrophobic protein and the few hydrophobic and hydrophilic tryptic peptides available in the digest is demonstrated with this robust new approach. MS and MS/MS spectra of BR tryptic peptides and intact protein were generally superior to the traditional solvent-based method using the desalted "dry" MALDI preparation procedure. The solvent-free method expands the range of peptides that can be effectively analyzed by MALDI-MS to those that are hydrophobic and solubility-limited.


Assuntos
Bacteriorodopsinas/química , Proteínas de Membrana/análise , Microquímica/métodos , Solventes/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Sequência de Aminoácidos , Cátions , Interações Hidrofóbicas e Hidrofílicas , Proteínas de Membrana/química , Proteínas de Membrana/metabolismo , Dados de Sequência Molecular , Peptídeos/análise , Peptídeos/química , Peptídeos/metabolismo , Sais/isolamento & purificação , Sódio/isolamento & purificação , Solubilidade
15.
J Biochem Biophys Methods ; 15(3-4): 163-76, 1987 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-3443700

RESUMO

We have recently described an apparatus for protein purification based on a segmented Immobiline gel, having one or more liquid interlayers in between. The principle is entirely new, as it is based on keeping the protein of interest isoelectric, in a flow chamber, and focusing the impurities in an Immobiline gel. For this, a hydraulic flow is coupled orthogonally to an electric flow, sweeping away the non-isoelectric impurities from the recycling chamber. We now demonstrate that the present apparatus can be efficiently used for protein desalting. Hemoglobin A samples, containing 50 mM NaCl or 50 mM ammonium acetate, could be efficiently desalted in 2 h of recycling, after which the total salt content had decreased to less than 0.005 mM (a salt decrement of more than 10,000 fold the initial input). However, with polyprotic buffers (sulphate, citrate, phosphate, oligoamines) the desalting process was much slower, typically of the order of 20 h, possibly due to interaction of these species with the surrounding Immobiline matrix. In this last case, outside pH control (e.g. with a pH-stat) is necessary during protein purification, as, due to the faster removal of the monovalent counterion, the solution in the recycling chamber can become rather acidic or alkaline. It is demonstrated that the 2 extremities of the Immobiline segments facing the sample recycling chamber act indeed as isoelectric membranes, having a good buffering capacity, preventing the protein macroion from leaving the chamber by continuously titrating it to its isoelectric point.


Assuntos
Focalização Isoelétrica/métodos , Proteínas/isolamento & purificação , Sais/isolamento & purificação , Condutividade Elétrica , Concentração de Íons de Hidrogênio , Focalização Isoelétrica/instrumentação , Cinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA