Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 151.552
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 103(18): e38003, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38701295

RESUMO

This study aims to investigate the ability of bone marrow imaging using third-generation dual-energy computed tomography (CT) virtual noncalcium (VNCa) to differentiate between multiple myeloma (MM) with diffuse bone marrow infiltration and red bone marrow (RBM). Bone marrow aspiration or follow-up results were used as reference. We retrospectively reviewed 188 regions of interests (ROIs) from 21 patients with confirmed MM and diffuse bone marrow infiltrations who underwent VNCa bone marrow imaging between May 2019 and September 2022. At the same time, we obtained 98 ROIs from 11 subjects with RBM for comparative study, and 189 ROIs from 20 subjects with normal yellow bone marrow for the control group. The ROIs were delineated by 2 radiologists independently, the interobservers reproducibility was evaluated by interclass correlation coefficients. The correlation with MRI grade results was analyzed by Spearman correlation coefficient. Receiver operating characteristic (ROC) curve analysis was used to determine the optimal threshold for differentiating between these groups and to assess diagnostic performance. There were statistically significant differences in VNCa CT values of bone marrow among the MM, RBM, and control groups (all P < .001), with values decreasing sequentially. A strong positive rank correlation was observed between normal bone marrow, subgroup MM with moderately and severe bone marrow infiltration divided by MRI and their corresponding CT values (ρ = 0.897, 95%CI: 0.822 to 0.942, P < .001). When the CT value of VNCa bone marrow was 7.15 HU, the area under the curve (AUC) value for differentiating RBM and MM was 0.723, with a sensitivity of 50.5% and a specificity of 89.8%. When distinguishing severe bone marrow infiltration of MM from RBM, the AUC value was 0.80 with a sensitivity 70.9% and a specificity 78.9%. The AUC values for MM, RBM, and the combined group compared to the control group were all >0.99, with all diagnostic sensitivity and specificity exceeding 95%. VNCa bone marrow imaging using third-generation dual-energy CT accurately differentiates MM lesions from normal bone marrow or RBM. It demonstrates superior diagnostic performance in distinguishing RBM from MM with diffuse bone marrow infiltration.


Assuntos
Medula Óssea , Mieloma Múltiplo , Tomografia Computadorizada por Raios X , Humanos , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/patologia , Mieloma Múltiplo/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medula Óssea/diagnóstico por imagem , Medula Óssea/patologia , Idoso , Diagnóstico Diferencial , Tomografia Computadorizada por Raios X/métodos , Adulto , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Med Virol ; 96(5): e29521, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38727013

RESUMO

Methylation panels, tools for investigating epigenetic changes associated with diseases like cancer, can identify DNA methylation patterns indicative of disease, providing diagnostic or prognostic insights. However, the application of methylation panels focusing on the sex-determining region Y-box 1 (SOX1) and paired box gene 1 (PAX1) genes for diagnosing cervical lesions is under-researched. This study aims to examine the diagnostic performance of PAX1/SOX1 gene methylation as a marker for cervical precancerous lesions and its potential application in triage diagnosis. From September 2022 to April 2023, 181 patients with abnormal HPV-DNA tests or cytological exam results requiring colposcopy were studied at Hubei Maternal and Child Health Hospital, China. Data were collected from colposcopy, cytology, HPV-DNA tests, and PAX1/SOX1 methylation detection. Patients were categorized as control, cervical intraepithelial neoplasia Grade 1 (CIN1), Grade 2 (CIN2), Grade 3 (CIN3), and cervical cancer (CC) groups based on histopathology. We performed HPV testing, liquid-based cytology, and PAX1/SOX1 gene methylation testing. We evaluated the diagnostic value of methylation detection in cervical cancer using DNA methylation positivity rate, sensitivity, specificity, and area under the curve (AUC), and explored its potential for triage diagnosis. PAX1/SOX1 methylation positivity rates were: control 17.1%, CIN1 22.5%, CIN2 100.0%, CIN3 90.0%, and CC 100.0%. The AUC values for PAX1 gene methylation detection in diagnosing CIN1+, CIN2+, and CIN3+ were 0.52 (95% confidence interval [CI]: 0.43-0.62), 0.88 (95% CI: 0.80-0.97), and 0.88 (95% CI: 0.75-1.00), respectively. Corresponding AUC values for SOX1 gene methylation detection were 0.47 (95% CI: 0.40-0.58), 0.80 (95% CI: 0.68-0.93), and 0.92 (95% CI: 0.811-1.00), respectively. In HPV16/18-negative patients, methylation detection showed sensitivity of 32.4% and specificity of 83.7% for CIN1+. For CIN2+ and CIN3+, sensitivity was all 100%, with specificities of 83.0% and 81.1%. Among the patients who underwent colposcopy examination, 166 cases had cytological examination results ≤ASCUS, of which 37 cases were positive for methylation, and the colposcopy referral rate was 22.29%. PAX1/SOX1 gene methylation detection exhibits strong diagnostic efficacy for cervical precancerous lesions and holds significant value in triage diagnosis.


Assuntos
Metilação de DNA , Fatores de Transcrição Box Pareados , Infecções por Papillomavirus , Fatores de Transcrição SOXB1 , Triagem , Displasia do Colo do Útero , Neoplasias do Colo do Útero , Humanos , Feminino , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/genética , Fatores de Transcrição SOXB1/genética , Adulto , Displasia do Colo do Útero/diagnóstico , Displasia do Colo do Útero/genética , Displasia do Colo do Útero/virologia , Pessoa de Meia-Idade , Triagem/métodos , Fatores de Transcrição Box Pareados/genética , Infecções por Papillomavirus/diagnóstico , Infecções por Papillomavirus/virologia , Infecções por Papillomavirus/genética , Sensibilidade e Especificidade , Biomarcadores Tumorais/genética , China , Lesões Pré-Cancerosas/diagnóstico , Lesões Pré-Cancerosas/genética , Adulto Jovem , Detecção Precoce de Câncer/métodos , Colposcopia
3.
J Med Virol ; 96(5): e29652, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38727029

RESUMO

Human papillomavirus (HPV) genotyping is widely used, particularly in combination with high-risk (HR) HPV tests for cervical cancer screening. We developed a genotyping method using sequences of approximately 800 bp in the E6/E7 region obtained by PacBio single molecule real-time sequencing (SMRT) and evaluated its performance against MY09-11 L1 sequencing and after the APTIMA HPV genotyping assay. The levels of concordance of PacBio E6/E7 SMRT sequencing with MY09-11 L1 sequencing and APTIMA HPV genotyping were 100% and 90.8%, respectively. The sensitivity of PacBio E6/EA7 SMRT was slightly greater than that of L1 sequencing and, as expected, lower than that of HR-HPV tests. In the context of cervical cancer screening, PacBio E6/E7 SMRT is then best used after a positive HPV test. PacBio E6/E7 SMRT genotyping is an attractive alternative for HR and LR-HPV genotyping of clinical samples. PacBio SMRT sequencing provides unbiased genotyping and can detect multiple HPV infections and haplotypes within a genotype.


Assuntos
Genótipo , Técnicas de Genotipagem , Papillomaviridae , Infecções por Papillomavirus , Humanos , Infecções por Papillomavirus/virologia , Infecções por Papillomavirus/diagnóstico , Feminino , Técnicas de Genotipagem/métodos , Papillomaviridae/genética , Papillomaviridae/classificação , Papillomaviridae/isolamento & purificação , Sensibilidade e Especificidade , Neoplasias do Colo do Útero/virologia , Neoplasias do Colo do Útero/diagnóstico , Análise de Sequência de DNA/métodos , Detecção Precoce de Câncer/métodos , Proteínas Oncogênicas Virais/genética , DNA Viral/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos
4.
Parasit Vectors ; 17(1): 206, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38715089

RESUMO

BACKGROUND: Opisthorchiasis and cholangiocarcinoma (CCA) continue to be public health concerns in many Southeast Asian countries. Although the prevalence of opisthorchiasis is declining, reported cases tend to have a light-intensity infection. Therefore, early detection by using sensitive methods is necessary. Several sensitive methods have been developed to detect opisthorchiasis. The immunological detection of antigenic proteins has been proposed as a sensitive method for examining opisthorchiasis. METHODS: The Opisthorchis viverrini antigenic proteins, including cathepsin B (OvCB), asparaginyl endopeptidase (OvAEP), and cathepsin F (OvCF), were used to construct multi-antigenic proteins. The protein sequences of OvCB, OvAEP, and OvCF, with a high probability of B cell epitopes, were selected using BepiPred 1.0 and the IEDB Analysis Resource. These protein fragments were combined to form OvCB_OvAEP_OvCF recombinant DNA, which was then used to produce a recombinant protein in Escherichia coli strain BL21(DE3). The potency of the recombinant protein as a diagnostic target for opisthorchiasis was assessed using immunoblotting and compared with that of the gold standard method, the modified formalin-ether concentration technique. RESULTS: The recombinant OvCB_OvAEP_OvCF protein showed strong reactivity with total immunoglobulin G (IgG) antibodies against light-intensity O. viverrini infections in the endemic areas. Consequently, a high sensitivity (100%) for diagnosing opisthorchiasis was reported. However, cross-reactivity with sera from other helminth and protozoan infections (including taeniasis, strongyloidiasis, giardiasis, E. coli infection, enterobiasis, and mixed infection of Echinostome spp. and Taenia spp.) and no reactivity with sera from patients with non-parasitic infections led to a reduced specificity of 78.4%. In addition, the false negative rate (FNR), false positive rate (FPR), positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were 0%, 21.6%, 81.4%, 100%, and 88.9%, respectively. CONCLUSIONS: The high sensitivity of the recombinant OvCB_OvAEP_OvCF protein in detecting opisthorchiasis demonstrates its potential as an opisthorchiasis screening target. Nonetheless, research on reducing cross-reactivity should be undertaken by detecting other antibodies in other sample types, such as saliva, urine, and feces.


Assuntos
Antígenos de Helmintos , Opistorquíase , Opisthorchis , Opistorquíase/diagnóstico , Opisthorchis/imunologia , Opisthorchis/genética , Animais , Antígenos de Helmintos/genética , Antígenos de Helmintos/imunologia , Humanos , Anticorpos Anti-Helmínticos/sangue , Proteínas Recombinantes/imunologia , Proteínas Recombinantes/genética , Sensibilidade e Especificidade , Proteínas de Helminto/imunologia , Proteínas de Helminto/genética , Epitopos/imunologia , Epitopos/genética , Catepsina B/genética , Catepsina B/imunologia , Escherichia coli/genética , Cisteína Endopeptidases
5.
J Headache Pain ; 25(1): 70, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38711044

RESUMO

BACKGROUND: Recently, diagnostic criteria including a standardized MRI criterion were presented to identify patients suffering from idiopathic intracranial hypertension (IIH) proposing that IIH might be defined by two out of three objective findings (papilledema, ≥ 25 cm cerebrospinal fluid opening pressure (CSF-OP) and ≥ 3/4 neuroimaging signs). METHODS: To provide independent external validation, we retrospectively applied the proposed diagnostic criteria to our cohort of patients with clinical suspicion of IIH from the Vienna IIH database. Neuroimaging was reevaluated for IIH signs according to standardized definitions by a blinded expert neuroradiologist. We determined isolated diagnostic accuracy of the neuroimaging criterion (≥ 3/4 signs) as well as overall accuracy of the new proposed criteria. RESULTS: We included patients with IIH (n = 102) and patients without IIH (no-IIH, n = 23). Baseline characteristics were balanced between IIH and no-IIH groups, but papilledema and CSF-OP were significantly higher in IIH. For the presence of ≥ 3/4 MRI signs, sensitivity was 39.2% and specificity was 91.3% with positive predictive value (PPV) of 95.2% and negative predictive value (NPV) 25.3%. Reclassifying our cohort according to the 2/3 IIH definition correctly identified 100% of patients without IIH, with definite IIH and suggested to have IIH without papilledema by Friedman criteria, respectively. CONCLUSION: The standardized neuroimaging criteria are easily applicable in clinical routine and provide moderate sensitivity and excellent specificity to identify patients with IIH. Defining IIH by 2/3 criteria significantly simplifies diagnosis without compromising accuracy.


Assuntos
Imageamento por Ressonância Magnética , Pseudotumor Cerebral , Humanos , Feminino , Imageamento por Ressonância Magnética/normas , Imageamento por Ressonância Magnética/métodos , Masculino , Adulto , Pseudotumor Cerebral/diagnóstico por imagem , Pseudotumor Cerebral/diagnóstico , Estudos Retrospectivos , Sensibilidade e Especificidade , Pessoa de Meia-Idade , Papiledema/diagnóstico por imagem , Papiledema/diagnóstico
6.
Sci Rep ; 14(1): 12230, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806578

RESUMO

Pyuria in dipstick examination serves as the most widespread screening tool for urinary tract infections (UTI). The absence of pyuria, however, does not exclude UTI. We investigated the diagnostic value of urinary calprotectin, a mediator protein of the innate immune system, which is released by leukocytes, for the detection of UTI and compared it with dipstick pyuria. Since even low numbers of leukocytes in the urine significantly increase urinary calprotectin concentrations, calprotectin might be a more sensitive marker than pyuria detected by dipstick. All 162 patients were prospectively included and underwent a urine dipstick, urine culture, quantification of proteinuria and determination of calprotectin in the urine. Urinary calprotectin was determined using an enzyme-linked immunosorbent assay (ELISA). UTI was defined as urine cultures with detection of one or a maximum of two uropathogenic bacteria with ≥ 105 colony-forming units per millilitre (CFU/ml). Exclusion criteria were acute kidney injury, chronic renal insufficiency and tumors of the urinary tract. 71 (43.8%) patients had a UTI. Of the 91 patients without UTI, 23 had a contamination and 19 had evidence of ≥ 105 CFU/ml considered to be asymptomatic bacteriuria. The median calprotectin concentration in patients with UTI and pyuria was significantly higher than in patients with UTI and without pyuria (5510.4 vs. 544.7 ng/ml). In ROC analyses, calprotectin revealed an area under the curve (AUC) of 0.70 for the detection of significant bacteriuria. Pyuria in dipstick examinations provided an AUC of 0.71. There was no significant difference between these AUCs in the DeLong test (p = 0.9). In patients with evidence of significant bacteriuria but without pyuria, a significantly higher calprotectin concentration was measured in the urine than in patients with neither pyuria nor UTI (544.7 ng/ml vs 95.6 ng/ml, p = 0.029). Urinary calprotectin is non-inferior to dipstick pyuria in the detection of UTI.


Assuntos
Bacteriúria , Biomarcadores , Complexo Antígeno L1 Leucocitário , Infecções Urinárias , Humanos , Complexo Antígeno L1 Leucocitário/urina , Masculino , Feminino , Bacteriúria/diagnóstico , Bacteriúria/urina , Pessoa de Meia-Idade , Idoso , Biomarcadores/urina , Infecções Urinárias/diagnóstico , Infecções Urinárias/urina , Adulto , Piúria/urina , Piúria/diagnóstico , Estudos Prospectivos , Urinálise/métodos , Idoso de 80 Anos ou mais , Curva ROC , Ensaio de Imunoadsorção Enzimática , Sensibilidade e Especificidade
7.
Commun Biol ; 7(1): 657, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806596

RESUMO

Despite recent technological advancements in cell tumor DNA (ctDNA) mutation detection, challenges persist in identifying low-frequency mutations due to inadequate sensitivity and coverage of current procedures. Herein, we introduce a super-sensitivity and specificity technique for detecting ctDNA mutations, named HiCASE. The method utilizes PCR-based CRISPR, coupled with the restriction enzyme. In this work, HiCASE focuses on testing a series of EGFR mutations to provide enhanced detection technology for non-small cell lung cancer (NSCLC), enabling a detection sensitivity of 0.01% with 40 ng cell free DNA standard. When applied to a panel of 140 plasma samples from 120 NSCLC patients, HiCASE exhibits 88.1% clinical sensitivity and 100% specificity with 40 µL of plasma, higher than ddPCR and Super-ARMS assay. In addition, HiCASE can also clearly distinguish T790M/C797S mutations in different positions at a 1% variant allele frequency, offering valuable guidance for drug utilization. Indeed, the established HiCASE assay shows potential for clinical applications.


Assuntos
Sistemas CRISPR-Cas , Carcinoma Pulmonar de Células não Pequenas , DNA Tumoral Circulante , Receptores ErbB , Neoplasias Pulmonares , Mutação , Humanos , DNA Tumoral Circulante/genética , DNA Tumoral Circulante/sangue , Receptores ErbB/genética , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/sangue , Neoplasias Pulmonares/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/genética , Carcinoma Pulmonar de Células não Pequenas/sangue , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Sensibilidade e Especificidade , Análise Mutacional de DNA/métodos , Feminino , Masculino
9.
Clinics (Sao Paulo) ; 79: 100383, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38797123

RESUMO

BACKGROUND: Neonatal Intrahepatic Cholestasis (NICCD), as the early-age stage of Citrin deficiency involving liver dysfunction, lacks efficient diagnostic markers. Procalcitonin (PCT) has been identified as a biomarker for infection as well as various organ damage. This study aimed to explore the potential of PCT as a biomarker for NICCD. METHODS: In a single-center retrospective case-control study. Serum PCT concentrations before and after treatment of 120 NICCD patients, as the study group, were compared to the same number of cholestatic hepatitis patients, as the control group. The potential value of PCT to discriminate NICCD from control disease was further explored using Receiver Operating Characteristic (ROC) curve analysis and compared to those of other inflammatory markers. RESULTS: There was a significantly higher level of PCT in NICCD patients than in the control group. PCT concentrations were only weakly correlated with neutrophil counts and CRP levels (p ˂ 0.05). At a cut-off value of 0.495 ng/mL, PCT exhibited a significantly higher diagnostic value compared to other inflammatory markers for discriminating NICCD from the control, with a sensitivity of 90.8 % and specificity of 98.3 %. CONCLUSION: PCT might be used as an initial biomarker to discriminate children with NICCD from another hepatitis disease.


Assuntos
Biomarcadores , Colestase Intra-Hepática , Citrulinemia , Pró-Calcitonina , Curva ROC , Humanos , Pró-Calcitonina/sangue , Biomarcadores/sangue , Estudos Retrospectivos , Masculino , Feminino , Estudos de Casos e Controles , Colestase Intra-Hepática/sangue , Colestase Intra-Hepática/diagnóstico , Citrulinemia/sangue , Citrulinemia/complicações , Citrulinemia/diagnóstico , Lactente , Recém-Nascido , Sensibilidade e Especificidade , Proteína C-Reativa/análise , Valores de Referência
10.
Rev Soc Bras Med Trop ; 57: e007052024, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38808801

RESUMO

BACKGROUND: Accurate diagnosis of paracoccidioidomycosis is crucial for improving patient outcomes. Paracoccidioides antibody detection by double immunodiffusion (DID) is a convenient diagnostic tool, but testing performance can vary based on certain factors. METHODS: We assessed DID performance using a commercially prepared Paracoccidioides reagents (IMMY, USA), involving 40 serum specimens, including 20 from patients with proven paracoccidioidomycosis and 20 from patients without the disease. The DID test demonstrated a sensitivity of 90% (95% CI=68%-99%) and a specificity of 100% (95% CI=83%-100%). CONCLUSIONS: Our findings suggest that DID using commercial reagents may provide a feasible tool with satisfactory testing performance for anti-Paracoccidioides antibody detection.


Assuntos
Anticorpos Antifúngicos , Imunodifusão , Paracoccidioides , Paracoccidioidomicose , Sensibilidade e Especificidade , Humanos , Anticorpos Antifúngicos/sangue , Paracoccidioidomicose/diagnóstico , Paracoccidioidomicose/imunologia , Paracoccidioides/imunologia , Kit de Reagentes para Diagnóstico , Feminino , Masculino
11.
Epidemiol Serv Saude ; 33: e2024008, 2024.
Artigo em Inglês, Português | MEDLINE | ID: mdl-38808901

RESUMO

OBJECTIVE: To create a protocol for performing minimally invasive autopsies (MIA) in detecting deaths from arboviruses and report preliminary data from its application in Ceará state, Brazil. METHODS: Training was provided to medical pathologists on MIA. RESULTS: A protocol was established for performing MIA, defining criteria for sample collection, storage methods, and diagnoses to be carried out according to the type of biological sample; 43 MIAs were performed in three months. Of these, 21 (48.8%) arrived at the Death Verification Service (SVO) with arboviruses as a diagnostic hypothesis, and seven (16.3%) were confirmed (six chikungunya cases and one dengue case); cases of COVID-19 (n = 9), tuberculosis (n = 5), meningitis (n = 4), cryptococcosis (n = 1), Creutzfeldt-Jakob disease (n = 1), breast cancer (n = 1), and human rabies (n = 1) were also confirmed. CONCLUSION: The protocol implemented enabled identification of a larger number of suspected arbovirus-related deaths, as well as confirmation of other diseases of interest for surveillance. MAIN RESULTS: A protocol was developed to perform minimally invasive autopsies (MIAs) in Death Verification Services (SVO), capable of expanding the system's capacity to identify a greater number of deaths suspected to be due to arboviruses. IMPLICATIONS FOR SERVICES: The experience suggests that in-service trained health professionals are able to perform MIA, and that use of this technique in SVOs has been shown to be capable of increasing the system's sensitivity in detecting deaths of interest to public health. PERSPECTIVES: Trained professionals will be able to collect biological material in hospitals, through MIA, in cases of interest for health surveillance and when family members do not allow a complete conventional autopsy to be performed.


Assuntos
Infecções por Arbovirus , Autopsia , Humanos , Brasil/epidemiologia , Autopsia/métodos , Infecções por Arbovirus/epidemiologia , Infecções por Arbovirus/diagnóstico , Infecções por Arbovirus/patologia , Feminino , Sensibilidade e Especificidade , Masculino , Pessoa de Meia-Idade , Adulto , Adolescente , Adulto Jovem , Arbovírus/isolamento & purificação , Idoso , Vigilância da População/métodos , Monitoramento Epidemiológico , Causas de Morte , Criança , Pré-Escolar
12.
Appl Microbiol Biotechnol ; 108(1): 350, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38809284

RESUMO

The African swine fever virus (ASFV) has the ability to infect pigs and cause a highly contagious acute fever that can result in a mortality rate as high as 100%. Due to the viral epidemic, the pig industry worldwide has suffered significant financial setbacks. The absence of a proven vaccine for ASFV necessitates the development of a sensitive and reliable serological diagnostic method, enabling laboratories to effectively and expeditiously detect ASFV infection. In this study, four strains of monoclonal antibodies (mAbs) against p72, namely, 5A1, 4C4, 8A9, and 5E10, were generated through recombinant expression of p72, the main capsid protein of ASFV, and immunized mice with it. Epitope localization was performed by truncated overlapping polypeptides. The results indicate that 5A1 and 4C4 recognized the amino acid 20-39 aa, 8A9 and 5E10 are recognized at 263-282 aa, which is consistent with the reported 265-280 aa epitopes. Conserved analysis revealed 20-39 aa is a high conservation of the epitopes in the ASFV genotypes. Moreover, a blocking ELISA assay for detection ASFV antibody based on 4C4 monoclonal antibody was developed and assessed. The receiver-operating characteristic (ROC) was performed to identify the best threshold value using 87 negative and 67 positive samples. The established test exhibited an area under the curve (AUC) of 0.9997, with a 95% confidence interval ranging from 99.87 to 100%. Furthermore, the test achieved a diagnostic sensitivity of 100% (with a 95% confidence interval of 95.72 to 100%) and a specificity of 98.51% (with a 95% confidence interval of 92.02 to 99.92%) when the threshold was set at 41.97%. The inter- and intra-batch coefficient of variation were below 10%, demonstrating the exceptional repeatability of the method. This method can detect the positive standard serum at a dilution as high as 1:512. Subsequently, an exceptional blocking ELISA assay was established with high diagnostic sensitivity and specificity, providing a novel tool for detecting ASFV antibodies. KEY POINTS: • Four strains of ASFV monoclonal antibodies against p72 were prepared and their epitopes were identified. • Blocking ELISA method was established based on monoclonal antibody 4C4 with an identified conservative epitope. • The established blocking ELISA method has a good effect on the detection of ASFV antibody.


Assuntos
Vírus da Febre Suína Africana , Febre Suína Africana , Anticorpos Monoclonais , Anticorpos Antivirais , Proteínas do Capsídeo , Ensaio de Imunoadsorção Enzimática , Mapeamento de Epitopos , Animais , Anticorpos Monoclonais/imunologia , Vírus da Febre Suína Africana/imunologia , Vírus da Febre Suína Africana/genética , Ensaio de Imunoadsorção Enzimática/métodos , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Suínos , Febre Suína Africana/diagnóstico , Febre Suína Africana/imunologia , Febre Suína Africana/virologia , Camundongos , Proteínas do Capsídeo/imunologia , Proteínas do Capsídeo/genética , Camundongos Endogâmicos BALB C , Sensibilidade e Especificidade , Epitopos/imunologia
13.
Breast Cancer Res ; 26(1): 85, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807211

RESUMO

BACKGROUND: Abbreviated breast MRI (FAST MRI) is being introduced into clinical practice to screen women with mammographically dense breasts or with a personal history of breast cancer. This study aimed to optimise diagnostic accuracy through the adaptation of interpretation-training. METHODS: A FAST MRI interpretation-training programme (short presentations and guided hands-on workstation teaching) was adapted to provide additional training during the assessment task (interpretation of an enriched dataset of 125 FAST MRI scans) by giving readers feedback about the true outcome of each scan immediately after each scan was interpreted (formative assessment). Reader interaction with the FAST MRI scans used developed software (RiViewer) that recorded reader opinions and reading times for each scan. The training programme was additionally adapted for remote e-learning delivery. STUDY DESIGN: Prospective, blinded interpretation of an enriched dataset by multiple readers. RESULTS: 43 mammogram readers completed the training, 22 who interpreted breast MRI in their clinical role (Group 1) and 21 who did not (Group 2). Overall sensitivity was 83% (95%CI 81-84%; 1994/2408), specificity 94% (95%CI 93-94%; 7806/8338), readers' agreement with the true outcome kappa = 0.75 (95%CI 0.74-0.77) and diagnostic odds ratio = 70.67 (95%CI 61.59-81.09). Group 1 readers showed similar sensitivity (84%) to Group 2 (82% p = 0.14), but slightly higher specificity (94% v. 93%, p = 0.001). Concordance with the ground truth increased significantly with the number of FAST MRI scans read through the formative assessment task (p = 0.002) but by differing amounts depending on whether or not a reader had previously attended FAST MRI training (interaction p = 0.02). Concordance with the ground truth was significantly associated with reading batch size (p = 0.02), tending to worsen when more than 50 scans were read per batch. Group 1 took a median of 56 seconds (range 8-47,466) to interpret each FAST MRI scan compared with 78 (14-22,830, p < 0.0001) for Group 2. CONCLUSIONS: Provision of immediate feedback to mammogram readers during the assessment test set reading task increased specificity for FAST MRI interpretation and achieved high diagnostic accuracy. Optimal reading-batch size for FAST MRI was 50 reads per batch. Trial registration (25/09/2019): ISRCTN16624917.


Assuntos
Neoplasias da Mama , Curva de Aprendizado , Imageamento por Ressonância Magnética , Mamografia , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Pessoa de Meia-Idade , Detecção Precoce de Câncer/métodos , Estudos Prospectivos , Idoso , Sensibilidade e Especificidade , Interpretação de Imagem Assistida por Computador/métodos , Mama/diagnóstico por imagem , Mama/patologia
14.
Radiology ; 311(2): e231879, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38771185

RESUMO

Background Multiparametric MRI (mpMRI) is effective for detecting prostate cancer (PCa); however, there is a high rate of equivocal Prostate Imaging Reporting and Data System (PI-RADS) 3 lesions and false-positive findings. Purpose To investigate whether fluorine 18 (18F) prostate-specific membrane antigen (PSMA) 1007 PET/CT after mpMRI can help detect localized clinically significant PCa (csPCa), particularly for equivocal PI-RADS 3 lesions. Materials and Methods This prospective study included participants with elevated prostate-specific antigen (PSA) levels referred for prostate mpMRI between September 2020 and February 2022. 18F-PSMA-1007 PET/CT was performed within 30 days of mpMRI and before biopsy. PI-RADS category and level of suspicion (LOS) were assessed. PI-RADS 3 or higher lesions at mpMRI and/or LOS 3 or higher lesions at 18F-PSMA-1007 PET/CT underwent targeted biopsies. PI-RADS 2 or lower and LOS 2 or lower lesions were considered nonsuspicious and were monitored during a 1-year follow-up by means of PSA testing. Diagnostic accuracy was assessed, with histologic examination serving as the reference standard. International Society of Urological Pathology (ISUP) grade 2 or higher was considered csPCa. Results Seventy-five participants (median age, 67 years [range, 52-77 years]) were assessed, with PI-RADS 1 or 2, PI-RADS 3, and PI-RADS 4 or 5 groups each including 25 participants. A total of 102 lesions were identified, of which 80 were PI-RADS 3 or higher and/or LOS 3 or higher and therefore underwent targeted biopsy. The per-participant sensitivity for the detection of csPCa was 95% and 91% for mpMRI and 18F-PSMA-1007 PET/CT, respectively, with respective specificities of 45% and 62%. 18F-PSMA-1007 PET/CT was used to correctly differentiate 17 of 26 PI-RADS 3 lesions (65%), with a negative and positive predictive value of 93% and 27%, respectively, for ruling out or detecting csPCa. One additional significant and one insignificant PCa lesion (PI-RADS 1 or 2) were found at 18F-PSMA-1007 PET/CT that otherwise would have remained undetected. Two participants had ISUP 2 tumors without PSMA uptake that were missed at PET/CT. Conclusion 18F-PSMA-1007 PET/CT showed good sensitivity and moderate specificity for the detection of csPCa and ruled this out in 93% of participants with PI-RADS 3 lesions. Clinical trial registration no. NCT04487847 © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Turkbey in this issue.


Assuntos
Radioisótopos de Flúor , Imageamento por Ressonância Magnética Multiparamétrica , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Estudos Prospectivos , Idoso , Pessoa de Meia-Idade , Niacinamida/análogos & derivados , Oligopeptídeos , Compostos Radiofarmacêuticos , Próstata/diagnóstico por imagem , Sensibilidade e Especificidade
15.
Clin Nutr ESPEN ; 61: 46-51, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38777472

RESUMO

BACKGROUND & AIMS: Tools for screening of nutrition risk in patients with cancer are usually validated against other screening instruments. Here with the performance of Malnutrition Screening Tool (MST) and Nutritional Screening Tool (NUTRISCORE) to identify the risk of malnutrition was assessed. A full nutritional evaluation and diagnosis following criteria from the Global Leadership Initiative of Malnutrition (GLIM) was the reference standard for the classification of malnutrition. METHODS: Diagnostic test prospective analysis of adult patients with a confirmed diagnosis of cancer. MST, NUTRISCORE and nutritional evaluation and diagnosis by GLIM criteria were independently performed within 24 h of admission to a 4th tier hospital in Bogotá, Colombia. RESULTS: From 439 patients the sensitivity and specificity of MST was 75% and 94% and of NUTRISCORE 45% and 97% respectively. The area under receiver operating characteristic (ROC) curves were 0.90 for MST and 0.85 for NUTRISCORE (p = 0.003). CONCLUSION: The MST showed a significantly better diagnostic performance over NUTRISCORE for detection of malnutrition risk at admission to hospital of patients with cancer.


Assuntos
Desnutrição , Neoplasias , Avaliação Nutricional , Estado Nutricional , Humanos , Desnutrição/diagnóstico , Neoplasias/complicações , Feminino , Masculino , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Adulto , Curva ROC , Programas de Rastreamento/métodos , Colômbia , Sensibilidade e Especificidade , Hospitalização , Fatores de Risco , Medição de Risco
16.
Radiol Clin North Am ; 62(4): 687-701, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38777543

RESUMO

Abbreviated breast MR (AB-MR) imaging is a relatively new breast imaging tool, which maintains diagnostic accuracy while reducing image times compared with full-protocol breast MR (FP-MR) imaging. Breast imaging audits involve calculating individual and organizational metrics, which can be compared with established benchmarks, providing a standard against which performance can be measured. Unlike FP-MR imaging, there are no established benchmarks for AB-MR imaging but studies demonstrate comparable performance for cancer detection rate, positive predictive value 3, sensitivity, and specificity with T2. We review the basics of performing an audit, including strategies to implement if benchmarks are not being met.


Assuntos
Neoplasias da Mama , Mama , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Mama/diagnóstico por imagem , Feminino , Mama/diagnóstico por imagem , Sensibilidade e Especificidade , Auditoria Médica/métodos
17.
Radiol Clin North Am ; 62(4): 643-659, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38777540

RESUMO

Breast MR imaging and contrast-enhanced mammography (CEM) are both techniques that employ intravenously injected contrast agent to assess breast lesions. This approach is associated with a very high sensitivity for malignant lesions that typically exhibit rapid enhancement due to the leakiness of neovasculature. CEM may be readily available at the breast imaging department and can be performed on the spot. Breast MR imaging provides stronger enhancement than the x-ray-based techniques and offers higher sensitivity. From a patient perspective, both modalities have their benefits and downsides; thus, patient preference could also play a role in the selection of the imaging technique.


Assuntos
Neoplasias da Mama , Mama , Meios de Contraste , Imageamento por Ressonância Magnética , Mamografia , Humanos , Imageamento por Ressonância Magnética/métodos , Feminino , Mamografia/métodos , Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Aumento da Imagem/métodos , Sensibilidade e Especificidade
18.
Zhonghua Yi Xue Za Zhi ; 104(20): 1852-1859, 2024 May 28.
Artigo em Chinês | MEDLINE | ID: mdl-38782754

RESUMO

Objective: To explore the value of cervical cytologic DNA methylation for screening cervical cancer. Methods: This study was a prospective multicenter study conducted from May to October 2022 in Peking Union Medical College Hospital, Zhejiang Provincial People's Hospital, and the Second Affiliated Hospital of Zhejiang University School of Medicine. Women who accepted opportunistic cervical cancer screening in gynecological outpatient clinics were subjected to liquid-based thin-layer cytology testing (TCT), high-risk human papillomavirus (hrHPV) DNA testing and PAX1/JAM3 dual-genes methylation testing (PAX1m/JAM3m). Colposcopy evaluation and biopsy were offered to women according to current guidelines. The accuracies of various testing methods and their combinations were compared based on histological diagnosis. Results: A total of 1 184 samples diagnosed by histopathology were included in this study, consisting of 541 cases (45.7%) of benign cervical tissue or chronic cervicitis, 273 (23.1%) of cervical intraepithelial neoplasia (CIN) 1, 168 (14.2%) of CIN2, 140 (11.8%) of CIN3, and 62 (5.2%) of cervical cancer. The sensitivity and specificity of PAX1m/JAM3m testing for detecting CIN2 or more severe lesions (CIN2+) were 74.1% and 95.9%, respectively. The sensitivity and specificity of PAX1m/JAM3m testing for detecting CIN3+were 87.6% and 86.8%, respectively. Receiver operating characteristic curve analysis showed that, for detecting CIN3+, the area under curve of PAX1m/JAM3m testing (0.872, 95%CI: 0.847-0.897) was significantly superior to TCT testing (0.580, 95%CI: 0.551-0.610) or hrHPV testing (0.503, 95%CI: 0.479-0.515) (all P values<0.05). Conclusions: The PAX1m/JAM3m test in cervical exfoliated cells has excellent accuracy for the diagnosis of both CIN2+and CIN3+, which is superior to traditional screening protocols and screening strategies.


Assuntos
Metilação de DNA , Detecção Precoce de Câncer , Fatores de Transcrição Box Pareados , Sensibilidade e Especificidade , Displasia do Colo do Útero , Neoplasias do Colo do Útero , Humanos , Feminino , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/genética , Estudos Prospectivos , Fatores de Transcrição Box Pareados/genética , Detecção Precoce de Câncer/métodos , Displasia do Colo do Útero/diagnóstico , Displasia do Colo do Útero/genética , Colposcopia , Colo do Útero/patologia , Programas de Rastreamento/métodos , Papillomaviridae/genética , Papillomaviridae/isolamento & purificação , Adulto
20.
J Cancer Res Clin Oncol ; 150(5): 268, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38772976

RESUMO

PURPOSE: Papillary thyroid carcinoma (PTC) with metastatic lymph nodes (LNs) is closely associated with disease recurrence. This study accessed the value of superb microvascular imaging (SMI) in the diagnosis and prediction of metastatic cervical LNs in patients with PTC. METHODS: A total of 183 cervical LNs (103 metastatic and 80 reactive) from 116 patients with PTC were analysed. Metastatic cervical LNs were confirmed by pathology or/and cytology; reactive cervical LNs were confirmed by pathology or clinical features. The characteristic of conventional ultrasound (US) was extracted using univariate and multivariate analyses. The diagnostic performance of US and SMI were compared using the area under the receiver operating curve (AUC) with corresponding sensitivity and specificity. A nomogram was developed to predict metastatic LNs in patients with PTC, based on multivariate analyses. RESULTS: L/S < 2, ill-defined border, absence of hilum, isoechoic or hyperechoic, heterogeneous internal echo, peripheral or mixed vascular pattern on color Doppler flow imaging (CDFI) and SMI, and a larger SMI vascular index appeared more frequently in metastatic LNs in the training datasets than in reactive LNs (P < 0.05). The diagnostic sensitivity, specificity and accuracy of SMI vs US are 94.4% and 87.3%, 79.3% and 69.3%, and 87.6% and 79.1%, respectively; SMI combined with US exhibited a higher AUC [0.926 (0.877-0.975)] than US only [0.829 (0.759-0.900)]. L/S < 2, peripheral or mixed vascular type on CDFI, and peripheral or mixed vascular types on SMI were independent predictors of metastatic LNs with PTC. The nomogram based on these three parameters exhibited excellent discrimination, with an AUC of 0.926. CONCLUSION: SMI was superior to US in diagnosing metastatic LNs in PTC. US combined with SMI significantly improved the diagnostic accuracy of metastatic cervical LNs with PTC. SMI is efficacious for differentiating and predicting metastatic cervical LNs.


Assuntos
Linfonodos , Metástase Linfática , Câncer Papilífero da Tireoide , Neoplasias da Glândula Tireoide , Humanos , Feminino , Metástase Linfática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Neoplasias da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Câncer Papilífero da Tireoide/diagnóstico por imagem , Câncer Papilífero da Tireoide/patologia , Adulto , Linfonodos/patologia , Linfonodos/diagnóstico por imagem , Microvasos/diagnóstico por imagem , Microvasos/patologia , Idoso , Adulto Jovem , Pescoço/diagnóstico por imagem , Nomogramas , Adolescente , Carcinoma Papilar/diagnóstico por imagem , Carcinoma Papilar/patologia , Carcinoma Papilar/secundário , Estudos Retrospectivos , Curva ROC , Ultrassonografia/métodos , Sensibilidade e Especificidade , Ultrassonografia Doppler em Cores/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA