Resultados 1 - 20 de 1.607
Filtrar
1.
Turk J Ophthalmol ; 54(2): 63-68, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38644781

RESUMO

Objectives: To evaluate the clinical results of a new trifocal intraocular lens (IOL) with sinusoidal design by comparing with a traditional trifocal IOL. Materials and Methods: A total of 79 patients undergoing uneventful microincisional cataract surgery with bilateral implantation of one of two types of trifocal IOLs, the Acriva Trinova IOL (VSY) or Acrysof IQ PanOptix IOL (Alcon), were enrolled in this prospective study. Visual and refractive outcomes, contrast sensitivity (CS), and defocus curve were assessed at 3 months after surgery. Patient satisfaction and incidence of photic phenomena were also evaluated. Results: The number of patients/eyes were 48/96 in the Trinova group and 31/62 in the PanOptix group. There were no significant differences between the groups for monocular and binocular corrected/uncorrected distance or intermediate (at 60 cm) and near visual acuities (VA) postoperatively. The Trinova group had statistically significantly better intermediate VA at 80 cm than the PanOptix group (p<0.05). The CS results of both groups were within the normal limits. In the binocular defocus curve of both IOLs, we observed a peak of good VA at 0.0 diopters defocus and a useful wide range for intermediate distances. The incidence of photic phenomena in the Trinova group was lower at postoperative 1 month (p<0.05) but this difference disappeared at 3 months. A total of 47 patients (97.9%) in the Trinova group and 30 patients (96.7%) in the PanOptix group stated that they would recommend the same IOL. Conclusion: Both trifocal IOLs provide good visual quality outcomes and patient satisfaction.


Assuntos
Lentes Intraoculares Multifocais , Presbiopia , Desenho de Prótese , Refração Ocular , Acuidade Visual , Humanos , Estudos Prospectivos , Feminino , Masculino , Acuidade Visual/fisiologia , Idoso , Pessoa de Meia-Idade , Presbiopia/fisiopatologia , Presbiopia/cirurgia , Refração Ocular/fisiologia , Visão Binocular/fisiologia , Satisfação do Paciente , Sensibilidades de Contraste/fisiologia , Facoemulsificação , Seguimentos , Implante de Lente Intraocular/métodos , Lentes Intraoculares
2.
Adv Nutr ; 15(5): 100216, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38582248

RESUMO

Antioxidants are bioactive molecules that function to scavenge free radicals and balance oxidative stress. Although all antioxidants can act as reactive oxygen species scavengers, their efficacy on eye health may vary. Moreover, the comparative effectiveness and potential additive effect between groups of antioxidants, hitherto, have not been systematically studied. A systematic review and network meta-analysis were conducted to investigate the comparative or additive effect of dietary antioxidant supplements on eye health. Four databases (PubMed, Embase, CINAHL, and Cochrane) were searched, and relevant randomized controlled trials were identified. Out of 60 articles selected for systematic review, 38 were included in the network meta-analysis, categorized into 8 distinct antioxidant-supplemented groups and placebo. All groups significantly increased macular pigment optical density and contrast sensitivity at low spatial frequency, whereas only the antioxidant mixture + lutein (L) + fatty acid combination exhibited significant improvements in visual acuity (hazard ratio = -0.15; 95% confidence interval: -0.28, -0.02) and L + zeaxanthin combination for photostress recovery time (hazard ratio = -5.75; 95% confidence interval: -8.80, -1.70). Especially, the L + zeaxanthin + fatty acid combination was ranked best for macular pigment optical density (surface under the cumulative ranking: 99.3%) and second best for contrast sensitivity at low spatial frequency (67.7%). However, these findings should be interpreted with caution due to low quality of evidence, primarily influenced by indirectness and potential publication bias. Overall, antioxidant supplementation was estimated to improve eye health parameters, whereas different combinations of antioxidants may also have varying effects on improving visual health from multiple perspectives. This study was registered at PROSPERO as CRD42022369250.


Assuntos
Antioxidantes , Suplementos Nutricionais , Luteína , Pigmento Macular , Ensaios Clínicos Controlados Aleatórios como Assunto , Acuidade Visual , Humanos , Antioxidantes/administração & dosagem , Antioxidantes/farmacologia , Luteína/farmacologia , Luteína/administração & dosagem , Acuidade Visual/efeitos dos fármacos , Zeaxantinas/farmacologia , Zeaxantinas/administração & dosagem , Metanálise em Rede , Sensibilidades de Contraste/efeitos dos fármacos
3.
Indian J Ophthalmol ; 72(Suppl 3): S505-S508, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38648459

RESUMO

PURPOSE: The Pelli-Robson and LEA contrast sensitivity charts are commonly used in clinical settings to measure contrast sensitivity. Although the Pelli-Robson chart is considered the gold standard, it is limited by its bulky size. The LEA chart, on the contrary, offers a more practical and portable option that is still reliable. This has led to questions about whether we can predict Pelli-Robson scores based on LEA scores. This study developed a conversion method to help transition from the LEA chart to the Pelli-Robson chart and validate the conversion score. METHODS: In this retrospective study, we analyzed the relationship between LEA and the Pelli-Robson contrast sensitivity test. Our study examined a total of 120 eyes. We developed a conversion table through the equipercentile equating method. Subsequently, we assessed the reliability and accuracy of this algorithm for converting LEA results into Pelli-Robson contrast sensitivity scores. RESULTS: The study used a conversion table to convert LEA scores to Pelli-Robson scores. The conversion table achieved a reliability of 0.91 based on intraclass correlation, and the algorithm had an accuracy of 81.6% within a 1-point difference from the raw score. CONCLUSIONS: This study reported a reliable and comparable conversion algorithm for transforming LEA scores into converted estimated Pelli-Robson scores, thereby improving the usefulness of existing data in both clinical and research contexts.


Assuntos
Sensibilidades de Contraste , Humanos , Sensibilidades de Contraste/fisiologia , Estudos Retrospectivos , Masculino , Feminino , Adulto , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Testes Visuais/métodos , Testes Visuais/instrumentação , Oftalmologia/métodos , Adulto Jovem , Acuidade Visual/fisiologia , Neurologia/métodos , Algoritmos , Idoso , Adolescente
4.
BMC Ophthalmol ; 24(1): 183, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649861

RESUMO

AIM: To evaluate the objective visual outcomes following implantation of extended depth of focus intraocular lens (EDOF IOL) in individuals with varying axial lengths (AL) and targeted refraction. METHODS: This retrospective study comprised age-matched eyes that underwent implantation of the EDOF IOL. Eyes were categorized based on AL into groups: control group with AL < 26 mm; high myopia group with AL ≥ 26 mm. Each group was then subdivided based on postoperative spherical equivalent (SE). Follow-up at three months included assessment of uncorrected visual acuity at different distances, contrast sensitivity (CS), refractive outcomes, and spectacle independence. RESULTS: Overall, this study included 100 eyes from 100 patients, comprising 50 males (50.00%) and 50 females (50.00%), with 20 eyes in each group. In the control group, the uncorrected distance visual acuity (UDVA) at 5 and 3 m (m) in the - 1.50 to -0.75 group was inferior to that of the - 0.75 to 0.00 group (P = 0.004). Conversely, the uncorrected near visual acuity (UNVA) at 33 cm in the - 1.50 to -0.75 group was superior to that of the - 0.75 to 0.00 group (P = 0.005). Within the high myopia group, the UDVA at 5 and 3 m in the - 2.25 to -1.50 group was worse than in the - 0.75 to 0.00 group (P = 0.009 and 0.008, respectively). However, the UNVA at 33 cm in the - 2.25 to -1.50 group was better than in the - 0.75 to 0.00 group (P = 0.020). No significant differences were observed among the groups for corrected distance visual acuity (CDVA) (P > 0.05). Additionally, in the high myopia group, the CS of the - 2.25 to -1.50 group was lower compared to that of the - 0.75 to 0.00 group (P = 0.017). Among high myopia patients, 90.00% with refraction ranging from - 1.50 to -0.75 reported achieving overall spectacle independence. CONCLUSIONS: Implantation of extended depth of focus intraocular lenses (IOLs) yields satisfactory visual and refractive outcomes in eyes with axial myopia. Among high myopia patients, a refraction ranging from - 1.50 to -0.75 diopters achieves superior visual quality compared to other postoperative myopic diopters.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Miopia , Refração Ocular , Acuidade Visual , Humanos , Feminino , Masculino , Estudos Retrospectivos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Miopia/fisiopatologia , Miopia/cirurgia , Idoso , Desenho de Prótese , Adulto , Sensibilidades de Contraste/fisiologia , Facoemulsificação , Pseudofacia/fisiopatologia , Comprimento Axial do Olho , Percepção de Profundidade/fisiologia , Seguimentos
5.
Ophthalmic Res ; 67(1): 221-231, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38493781

RESUMO

INTRODUCTION: The aim of this study was to investigate the efficacy of new monofocal intraocular lens (IOL) in comparison with conventional monofocal IOL in patients undergoing combined cataract and vitrectomy surgery for epiretinal membrane (ERM). METHODS: This prospective non-randomized comparative study included 65 eyes of 65 patients who underwent combined cataract and vitrectomy for ERM with implantation of advanced monofocal IOL (Eyhance ICB00, 33 patients) and standard monofocal IOL (Tecnis ZCB00, 32 patients). Monocular visual acuities were measured 6 months post-operatively, including corrected and uncorrected distance visual acuity (CDVA, UCDVA), uncorrected intermediate visual acuity (UCIVA), and uncorrected near visual acuity (UCNVA). Furthermore, contrast sensitivity and metamorphopsia were measured. RESULTS: There was no significant difference between two groups regarding operation time, post-operative CDVA, UCDVA, UCNVA, and spherical equivalent (p > 0.05). Monocular UCIVA was significantly higher in the Eyhance IOL group than in the Tecnis IOL group (p = 0.005). The photopic and mesopic contrast sensitivities were comparable between each group for any spatial frequency (p > 0.05). The correlation coefficients from correlations between retinal wrinkling ratio and M score did not differ significantly between groups (p = 0.877), and the degree of metamorphopsia was not significantly related to the type of IOL (p = 0.969). CONCLUSIONS: In combined cataract and vitrectomy for ERM, Eyhance IOL provided significant better visual performance at intermediate distance than standard monofocal IOL without compromising operation time, distance vision, contrast sensitivity, and evaluating metamorphopsia. Eyhance IOL can be a useful option for both surgeons and patients.


Assuntos
Catarata , Membrana Epirretiniana , Implante de Lente Intraocular , Lentes Intraoculares , Acuidade Visual , Vitrectomia , Humanos , Vitrectomia/métodos , Feminino , Masculino , Acuidade Visual/fisiologia , Estudos Prospectivos , Membrana Epirretiniana/cirurgia , Membrana Epirretiniana/fisiopatologia , Membrana Epirretiniana/diagnóstico , Idoso , Pessoa de Meia-Idade , Catarata/fisiopatologia , Catarata/complicações , Implante de Lente Intraocular/métodos , Sensibilidades de Contraste/fisiologia , Desenho de Prótese , Seguimentos , Resultado do Tratamento , Facoemulsificação/métodos
6.
Ophthalmic Physiol Opt ; 44(3): 584-592, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38349231

RESUMO

PURPOSE: To evaluate the optical and aberrometric outcomes of an enhanced monofocal intraocular lens (ISOPure) compared with those of a standard monofocal lens (MicroPure) having the same platform and material. METHODS: A prospective, comparative and randomised clinical study. A total of 28 eyes of 28 patients were randomly assigned to either group. Monocular visual acuity (VA) was measured at distance and intermediate under photopic and mesopic conditions. Aberrometry was analysed for 3.0-, 4.0-, 4.5- and 5.0 mm pupils. The contrast sensitivity defocus curve was measured for 3.0- and 4.5-mm pupils, while the modulation transfer function (MTF) and Strehl ratio (SR) were assessed with a double-pass system. All measurements were performed monocularly 3 months after surgery. RESULTS: No significant differences were found for distance VA. Under photopic conditions, intermediate VA was better with the ISOPure lens, while no significant differences were found between the lenses under mesopic conditions. Internal and total aberrations were higher for the ISOPure lens. No significant differences were found for corneal aberrations. Additionally, both the contrast sensitivity defocus curve and optical quality showed similar behaviour for each lens, with the MTF cut-off frequency exceeding 30 c/deg in both cases. CONCLUSION: The isofocal ISOPure lens enhanced intermediate VA without affecting distance VA under photopic conditions. Moreover, there were no significant differences in visual quality between the ISOPure and MicroPure lenses, despite the former exhibiting higher internal and total aberrations than the monofocal model.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Estudos Prospectivos , Acuidade Visual , Sensibilidades de Contraste , Desenho de Prótese
7.
BMC Ophthalmol ; 24(1): 74, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38369454

RESUMO

BACKGROUND: An enhanced monofocal intraocular lenses (IOLs) (Tecnis Eyhance ICB00 and Tecnis Eyhance Toric DIU) has been developed to enhance intermediate vision while avoiding the disadvantages of multifocal IOLs. Although many studies have demonstrated the improvement of intermediate visual acuity with enhanced monofocal IOLs, it is not known specifically for which patients these IOLs should be recommended or avoided. In this study, we aim to find out which ocular parameters affect vision performance and photic phenomenon of ICB00 or DIU at different distances. METHODS: Patients who underwent cataract surgery with ICB00 or DIU, performed by a single surgeon, were included. Before surgery, the patients' age, gender, axial length, anterior chamber depth, spherical aberration Z (4,0), vertical coma, horizontal coma, angle kappa (κ), angle alpha (α), and other ocular parameters were investigated. One month after surgery, uncorrected near visual acuity (UNVA at 40 cm), uncorrected intermediate visual acuity (UIVA at 66 cm), uncorrected distance logMAR visual acuity (UDVA), IOL decentration, and quality of vision (QoV) questionnaires were conducted. RESULTS: A total of 43 patients (58 eyes) were included. The results of the univariate linear regression analyses showed a negative correlation between spherical aberration and logMAR UNVA and UIVA (p = 0.003, ß=-0.51 and p = 0.018, ß=-0.23, respectively) and a positive correlation between angle α and logMAR UIVA (p = 0.036, ß = 0.19). Deeper anterior chamber depth (ACD) was associated with poorer total QoV (p = 0.018, ß = 14.43), particularly in glare, halo, blur, and fluctuation perception. A higher degree of IOL decentration tended to decrease UNVA and UIVA (Pearson correlation coefficient, r = 0.336 and r = 0.221, respectively); however, no significant effect was observed on UDVA (Pearson correlation coefficient, r = 0.042). CONCLUSIONS: In enhanced monofocal IOLs, a higher level of spherical aberration is associated with better performance in UNVA and UIVA, whereas a larger angle α has a negative impact. A deeper ACD negatively affects the QoV.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular/métodos , Coma , Sensibilidades de Contraste , Visão Ocular , Desenho de Prótese , Satisfação do Paciente , Refração Ocular
8.
Ophthalmic Surg Lasers Imaging Retina ; 55(4): 212-219, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38319059

RESUMO

BACKGROUND AND OBJECTIVE: We sought to establish normative quantitative contrast sensitivity function (qCSF) values in healthy adult eyes and investigate the effect of age on qCSF. PATIENTS AND METHODS: Healthy eyes underwent qCSF testing (adaptive sensory technology) and Snellen's visual acuity (VA). Descriptive statistics and mixed-effects multivariable linear regressions were evaluated. RESULTS: A total of 334 eyes (290 patients) with median age 61 years (range 21 to 88) had qCSF values as follows: area under the log contrast sensitivity function curve: 1.18; contrast acuity: 1.32; contrast sensitivity (CS) at 1 cycle per degree (cpd): 1.32; CS at 1.5 cpd: 1.37; CS at 3 cpd: 1.38; CS at 6 cpd: 1.20; CS at 12 cpd: 0.69; CS at 18 cpd: 0.22. Linear reductions in qCSF values per decade of age ranged from -0.02 to -0.07 vs 0.01 for visual acuity (VA). Age had a greater effect on the majority of qCSF values than VA (beta standardized regression coefficient ranged from -0.309 to -0.141 for qCSF values vs 0.177 for VA). CONCLUSIONS: We herein establish a normative database for qCSF and quantify the effect of age on qCSF values, adding evidence towards the validation of qCSF as a clinical endpoint. [Ophthalmic Surg Lasers Imaging Retina 2024;55:212-219.].


Assuntos
Envelhecimento , Sensibilidades de Contraste , Acuidade Visual , Humanos , Sensibilidades de Contraste/fisiologia , Adulto , Feminino , Masculino , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Idoso , Adulto Jovem , Idoso de 80 Anos ou mais , Envelhecimento/fisiologia , Voluntários Saudáveis , Valores de Referência , Bases de Dados Factuais
9.
Invest Ophthalmol Vis Sci ; 65(1): 3, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38165705

RESUMO

Purpose: Intermittent exotropia (IXT) is the most common form of strabismus. Surgery can potentially improve binocular function in patients with IXT. We aimed to evaluate binocular function using a novel parameter-binocular summation ratio (BSR), measured using quantitative contrast sensitivity function (CSF) in patients with IXT before and after surgery. Methods: Prospective study of 63 patients with IXT and 41 healthy controls were consecutively enrolled and underwent quantitative CSF testing binocularly and monocularly. BSR was calculated by dividing the CSF of the binocular value by the better monocular value. Forty-eight patients with IXT underwent strabismus surgery. BSR, stereoacuity, fusion ability, and strabismus questionnaires were assessed pre-operatively and 2 months postoperatively. Results: Sixty-three patients with IXT (median age = 9 years) compared with 41 healthy controls showed a worse mean BSR based on all CSF metrics at baseline (the area under the log CSF [AULCSF], spatial frequency [SF] cutoff, and contrast sensitivity at 1.0-18.0 cpd SF). All 48 patients with IXT showed successful alignment after surgery, and there were significant improvements in BSR based on the AULCSF, SF cutoff, and contrast sensitivity at 6.0, 12.0, and 18.0 cpd SF, respectively. The distance stereoacuity and fusion ability also improved after surgery, and a better BSR was associated with better stereoacuity and fusion. For strabismus questionnaires, the psychosocial subscale scores improved postoperatively, whereas the functional subscale scores did not change. Conclusions: BSR based on quantitative CSF can characterize binocular function across a range of spatial frequencies and can be used as a supplemental measurement for monitoring binocularity in patients with IXT in clinical settings.


Assuntos
Exotropia , Estrabismo , Humanos , Criança , Exotropia/cirurgia , Sensibilidades de Contraste , Visão Binocular , Estudos Prospectivos
10.
Curr Eye Res ; 49(2): 188-196, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37846084

RESUMO

PURPOSE: To assess the association of fundus tessellation with contrast sensitivity, Quality of Vision questionnaire, and other factors at five years postcorneal refractive surgery. METHODS: This is a cross-sectional study. Both eyes of 98 subjects (196 eyes) who received femtosecond laser in situ keratomileusis (FS-LASIK) or small incision lenticular extraction (SMILE) five years prior were enrolled in this study. Fundus tessellation was imaged using wide-angle fundus photographs and graded into four categories with the assistance of the ETDRS grid. Photopic and mesopic contrast sensitivity were measured under the best correction. The Quality of Vision (QoV) questionnaire was used to assess visual symptoms. RESULTS: Fundus tessellation was classified as follows: 19 eyes were grade 0 (9.7%), 28 eyes were grade 1 (14.3%), 59 eyes were grade 2 (30.1%), and 90 eyes were grade 3 (45.9%). Higher degrees of fundus tessellation were associated with lower photopic contrast sensitivity, a significant difference was observed at spatial frequencies of 6cpd (p = 0.030, grade 1 >grade 3 p = 0.011). Higher degrees of fundus tessellation were also associated with lower mesopic contrast sensitivity, a significant difference was observed at spatial frequencies of 18cpd (p = 0.011, grade 0 >grade 3 p = 0.012). The preoperative degree of myopia was positively associated with fundus tessellation grade (p < 0.001). However, in linear mixed-effect model analysis, no significant influence of parameters (contrast sensitivity, preoperative myopia, and QoV scores) upon different tessellation grades was found (p > 0.05). CONCLUSIONS: Patients with moderate and high myopia were more likely to have higher grades of fundus tessellation. Higher degree of fundus tessellation associates with lower contrast sensitivity. Patients with moderate and high myopia should be concerned with retinal-choroidal changes. Contrast sensitivity could be a clinical sign for progression of tessellation and used to screen for early retinal-choroidal changes to prevent pathologic myopia.


Assuntos
Anormalidades do Olho , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Sensibilidades de Contraste , Acuidade Visual , Estudos Transversais , Lasers de Excimer , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Miopia/diagnóstico , Miopia/cirurgia , Refração Ocular , Substância Própria/cirurgia
11.
Invest Ophthalmol Vis Sci ; 64(14): 7, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37934160

RESUMO

Purpose: The purpose of this study was to describe, validate, and compare the contrast sensitivity functions (CSFs) acquired with the novel quick CSF (qCSF) method from patients with early and intermediate age-related macular degeneration (eAMD and iAMD) and healthy controls. Methods: This is a cross-sectional analysis of contrast sensitivity (CS) and visual acuity (VA) baseline data from the prospective Multimodal Functional and Structural Visual System Characterization (MUMOVI) study. The qCSF testing was conducted with the manifold contrast vision meter (Adaptive Sensory Technology, San Diego, CA, USA). CS levels at spatial frequencies from 1 cycle per degree (CPD) to 18 CPD, the area underneath the logarithmic contrast sensitivity function (AULCSF), and contrast acuity (CA) were analyzed. The association of functional metrics with variables of interest was tested with linear models. Results: Ninety-four study eyes from 94 study patients were included in the analysis (13 patients with eAMD, 33 patients with iAMD, and 48 healthy controls). Significant differences between the eAMD and the iAMD model estimates were only found for CS at 1 CPD (t value = -2.9, P value = 0.006) and CS at 1.5 CPD (-2.7, 0.01). A specific association between smoking years and CS at 1 CPD (P = 0.02) and CS at 1.5 CPD (P = 0.03) could be described in patients with AMD. Conclusions: The qCSF testing allows the fast measurement of the whole CSF, enabling the integration into clinical routine. We showed that novel qCSF-derived metrics detect slight functional differences between AMD stages, which testing by Pelli-Robson charts or VA testing would miss. This study, therefore, yields novel qCSF-derived candidate metrics for therapeutic trials in AMD.


Assuntos
Sensibilidades de Contraste , Degeneração Macular , Humanos , Estudos Transversais , Estudos Prospectivos , Olho
12.
Int Ophthalmol ; 43(11): 4035-4053, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37464228

RESUMO

PURPOSE: To evaluate the efficacy of a new visual training program for improving the visual function in patients implanted with trifocal intraocular lenses (IOLs). METHODS: Randomised placebo-controlled clinical trial enrolling 60 subjects (age, 47-75 years) undergoing cataract surgery with implantation of trifocal diffractive IOL. Home-based active visual training was prescribed immediately after surgery to all of them (20 sessions, 30 min): 31 subjects using a serious game based on Gabor patches (study group) and 29 using a placebo software (placebo group). Visual acuity, contrast sensitivity (CS), and perception of visual disturbances (QoV questionnaire) were evaluated before and after training. Likewise, in a small subgroup, resting-state functional magnetic resonance imaging (rs-fMRI) analysis was performed. RESULTS: No significant differences were found between groups in compliance time (p = 0.70). After training, only significant improvements in monocular uncorrected intermediate visual acuity were found in the study group (p ≤ 0.01), although differences between groups did not reach statistical significance (p ≥ 0.11). Likewise, significantly better binocular far CS values were found in the study group for the spatial frequencies of 6 (p = 0.01) and 12 cpd (p = 0.03). More visual symptoms of the QoV questionnaire experienced a significant change in the level of bothersomeness in the study group. Rs-fMRI revealed the presence significant changes reflecting higher functional connectivity after the training with the serious game. CONCLUSIONS: A 3-week visual training program based on the use of Gabor patches after bilateral implantation of trifocal diffractive IOLs may be beneficial for optimising the visual function, with neural changes associated suggesting an acceleration of neuroadaptation. Trial registration ClinicalTrials.gov, NCT04985097. Registered 02 August 2021, https://clinicaltrials.gov/(NCT04985097 ).


Assuntos
Extração de Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Pessoa de Meia-Idade , Idoso , Refração Ocular , Acuidade Visual , Sensibilidades de Contraste , Desenho de Prótese , Satisfação do Paciente
13.
BMC Ophthalmol ; 23(1): 245, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37264304

RESUMO

PURPOSE: To investigate the binocular summation (BiS) of visual acuity (VA) and contrast sensitivity (CS) in children with intermittent exotropia (IXT) before and after surgery and to probe the relationship between the two BiS phenomena and corresponding influencing factors. METHODS: This prospective study included 21 IXT children (11 males and 10 females; aged 6-13 years) who underwent strabismus surgery in Tianjin Eye Hospital from January to April 2022. The visual function was assessed preoperatively and 2.95 ± 0.14 months postoperatively, including monocular/ binocular visual acuity (MVA/BVA) at 100% contrast and 2.5% contrast as well as monocular/binocular contrast sensitivity (MCS/BCS), deviation, near and distant stereopsis, and fusion. RESULTS: All patients had postoperative deviation ranging from 0 to -4 PD. Either preoperative or postoperative BVA at 2.5% contrast was superior to the MVA. The postoperative BiS at 2.5% contrast was significantly superior to the preoperative BiS for 2.5% contrast and postoperative BiS for 100% contrast (P < 0.05). Except for 3 c/d, the MCS and BCS at 6 c/d, 12 c/d and 18 c/d spatial frequencies were all notably improved postoperatively. The postoperative binocular summation ratio of CS (BSR) was highest while interocular difference ratio of CS (IOR) was the lowest at 6 c/d among 4 spatial frequencies. The deviation, distant and near stereopsis, and fusion performance were all remarkably improved after surgery (p = 0.001; p = 0.041; p = 0.000), all of which were not related to BVA at 2.5% contrast, BiS, BSC and BSR. The BCS at middle and high frequencies (6 c/ds, 12 c/ds, and 18 c/ds) was significantly negatively correlated with the BVA at 2.5% contrast, and BSR was irrelevant to the corresponding IOR across different spatial frequencies. CONCLUSION: BVA at low contrast and BCS examinations were not equivalent to stereopsis and fusion status, which contributed to the evaluation of binocular function in the real environment and in the different aspects. BVA in 2.5% contrast is related with BCS in moderate and high spacial frequencies (especially 18c/d) but BCS in 6c/d presents more binocular summation of contrast sensitivity. MCS, BCS and the BSR persist inhibition at 3c/d after surgery. The improvement of BCS is better than that of BSR to evaluate the binouclar function in IXT. Those two methods showed different sensitivities to impairment and rehabilitation of binocular summation and inhibition.


Assuntos
Sensibilidades de Contraste , Exotropia , Masculino , Feminino , Humanos , Criança , Exotropia/cirurgia , Estudos Prospectivos , Visão Binocular/fisiologia , Acuidade Visual
14.
Int Ophthalmol ; 43(9): 3309-3319, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37329407

RESUMO

PURPOSE: Glare visual acuity and contrast sensitivity are important indicators of visual quality. Studies have shown that the glare visual acuity and contrast sensitivity in dry eye patients tend to degenerate, further affecting their quality of life. The objective of this study was to investigate the effect of notch filters on glare VA and contrast sensitivity in patients with dry eye or with dry eye syndrome. METHOD: 36 subjects in the 20‒65 age group were diagnosed as having dry eye disease or perceived dry eye syndromes themselves who were included after the initial screening with the OSDI questionnaire, and one was subsequently excluded as they had undergone retinal detachment surgery. Finally, 35 subjects (14 male and 21 female) with a mean age of 40.66 ± 15.62 years participated in this study. All subjects wore their habitual prescriptions and four different filter lenses (namely 480, 620, dual 480 & 620 notch filter, and FL-41 tinted lens), and measured the parameters of glare visual acuity and contrast sensitivity using CSV-1000 and sine wave contrast test (SWCT), respectively. Student t-test and Repeated measurement analysis (R-ANOVA) were utilized by using SPSS 26.0 software. RESULTS: A dual-wavelength 480 & 620 nm optical notch filter had a significant anti-glare effect decreasing glare disabilities or discomfort, and leading to better visual quality, the same effect was also shown on a 480 nm notch filter lens. All participants showed a significant difference among the baseline, three notch filters (480 nm, 620 nm, dual-wavelength 480 & 620 nm), and FL-41 tinted lens were used on SWCT_A (1.5 cpd, F = 3.054, p = 0.019) and SWCT_E (18 cpd, F = 2.840, p = 0.049); but did not show statistical different on SWCT_B (3 cpd, F = 0.333, p = 0.771), SWCT_C (6 cpd, F = 1.779, p = 0.159), and SWCT_D (12 cpd, F = 1.447, p = 0.228). The baseline showed the best visual performance on CS at a low spatial frequency (SWCT_A, 1.5 cpd), any filter might reduce the contrast sensitivity at low spatial frequencies in the clinical trial, whereas 480 nm notch filter showed the best effectiveness on CS at a high spatial frequency (SWCT_E, 18 cpd), the FL-41 lens that also filters out the 480 nm band does not achieve the same effect. Moreover, patients with dry eye or those older than 40 years old preferred optical multilayer notch filters to FL-41 tinted lenses. CONCLUSION: The 480- & 620-nm dual-wavelength and 480-nm single-wavelength notch filters have the best effect on the glare visual acuity and contrast sensitivity (CS) at high spatial frequencies in dry eye patients. The 620-nm notch filter performs better in CS at low and mid-low spatial frequencies; the FL-41 tinted lens performs poorly for glare VA and CS spatial frequencies examination. Patients with glare disabilities or CS disturbance at high spatial frequencies may choose a 480-nm notch filter lens, and patients who have CS disturbance at low spatial frequencies may consider a 620-nm notch filter for the prescription.


Assuntos
Sensibilidades de Contraste , Síndromes do Olho Seco , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Qualidade de Vida , Acuidade Visual , Ofuscação , Síndromes do Olho Seco/diagnóstico
15.
Klin Monbl Augenheilkd ; 240(4): 426-434, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37164441

RESUMO

PURPOSE: To evaluate and compare the long-term results after bilateral implantation of different multifocal intraocular lenses (MIOLs). METHODS: This retrospective comparative study included 42 patients who underwent cataract surgery with bilateral MIOL implantation. Patients were divided into 5 groups: Group 1 received a refractive ReZoom NGX1 IOL (AMO), Group 2 a diffractive Acrysof ReSTOR SA60D3 IOL (Alcon), and Group 3 a diffractive Tecnis ZM900 IOL (AMO). Group 4 and Group 5 were implanted using the mix and match approach with refractive ReZoom-diffractive ReSTOR IOL and refractive ReZoom-diffractive Tecnis ZM900 IOL, respectively. Primary outcome measures were distance, near, and intermediate distance visual acuity measured 6 months (T0) and 10 years (T1) after surgery. Secondary outcomes were defocus curves, contrast sensitivity, patients' satisfaction, and spectacle independence. RESULTS: All patients achieved best-corrected distance visual acuity (BCDVA) greater than 0.11 logMAR and uncorrected distance visual acuity (UCDVA) greater than 0.14 logMAR at both time points. A decrease in contrast sensitivity was evident, particularly at high spatial frequencies; at T1, Group 4 reported statistically higher values than Group 2 at 12 cycles/degree and 18 cycles/degree and statistically higher values than Group 3 at 18 cycles/degree. Great overall satisfaction was reported even in the presence of dysphotopsia. Tecnis ZM900 IOL showed the lowest incidence of posterior capsular opacification. CONCLUSION: MIOLs could provide adequate functional vision and patient satisfaction, despite the incidence of side effects, in carefully selected patients desiring spectacle independence.


Assuntos
Lentes Intraoculares , Lentes Intraoculares Multifocais , Facoemulsificação , Humanos , Implante de Lente Intraocular/métodos , Seguimentos , Estudos Retrospectivos , Sensibilidades de Contraste , Satisfação do Paciente , Desenho de Prótese
16.
Saudi Med J ; 44(5): 456-462, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37182920

RESUMO

OBJECTIVES: To compare the subjective and objective visual quality more comprehensively after surgery of the commonly used multifocal intraocular lenses (IOL) and monolocal IOL implants through long-term systematic clinical observation, providing reference and basis for clinical application. METHODS: Non-randomized controlled trial. A total of 91 (138 eyes) patients between June 2020 and December 2020 were implanted trifocal IOL or monofocal IOL after phacoemulsification in a tertiary class hospital in Wuhan. Monocular testing 3 months after surgery included best-spectacles corrected and uncorrected visual at distant, intermediate, and near vision; spherical equivalent (SE); defocus curve; modulation transfer function (MTF); dysfunctional lens index (DLI); Strehl ratio (SR); mesopic contrast sensitivity function; quality-of-life, spectacles independence, visual disturbance, and surgical satisfaction surveys 3 months post-surgery. RESULTS: There was statistically better uncorrected vision acuity with trifocal IOLs in all range, while monofocal IOL had statistically better mesopic contrast sensitivity at specific spatial frequencies and statistically worse defocus curves, spectacles independence, and surgical satisfaction. The trifocal IOL performed better in subjective quality of vision and life and spectacles independence questionnaires, and the objective quality of vision had no statistical significance. CONCLUSION: Compared to monofocal IOL, trifocal IOL could provide a full range of clear vision for the majority of patients with simple cataracts, improve the rate of spectacles independence and patient satisfaction. And the objective quality of vision did not show any difference.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Humanos , Estudos Prospectivos , Acuidade Visual , Sensibilidades de Contraste , Satisfação do Paciente , Desenho de Prótese
17.
Graefes Arch Clin Exp Ophthalmol ; 261(8): 2315-2326, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37256375

RESUMO

PURPOSE: This study aimed to evaluate and compare the clinical outcomes obtained after cataract surgery with an aspheric monofocal intraocular lens (IOL) and an enhanced IOL with a modified optical profile. METHODS: Randomised clinical trial enrolling 70 patients (age, 52-87 years) undergoing cataract surgery. Two groups were created according to the type of IOL implanted: Vivinex iSert from Hoya Surgical Optics (Vivinex group, 35 patients) and Tecnis Eyhance ICB00 from Johnson & Johnson Vision (Eyhance group, 35 patients). Uncorrected (UDVA) and corrected distance visual acuity (CDVA), uncorrected (UIVA) and distance-corrected intermediate visual acuity (DCIVA), refraction, and self-perceived visual function (Catquest-9SF) were evaluated during a 3-month follow-up. RESULTS: No significant differences were found between IOL groups in UDVA and CDVA (p ≥ 0.093). In contrast, monocular and binocular UIVA and DCIVA were significantly better in the Eyhance group at 1 (p ≤ 0.015) and 3 months postoperatively (p ≤ 0.002). Postoperative DCIVA 20/25 or better was obtained in 71.4% and 20.0% of patients in Eyhance and Vivinex groups, respectively. Differences in postoperative Rasch calibrated Catquest scores between Eyhance and Vivinex groups did not reach statistical significance (p ≥ 0.102). However, significant correlations were only found between the change in UIVA and Catquest scores (0.364 ≤ r ≤ 0.444, p ≤ 0.041) in the Eyhance group. CONCLUSIONS: The modified monofocal IOL evaluated provides better intermediate visual function in comparison with a standard aspheric monofocal IOL, but the impact of this benefit on the self-perceived level of vision achieved after surgery according to the patient seemed to be limited.


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Sensibilidades de Contraste , Implante de Lente Intraocular , Satisfação do Paciente , Desenho de Prótese , Refração Ocular , Acuidade Visual
18.
Cesk Slov Oftalmol ; 79(2): 80-85, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37072255

RESUMO

PURPOSE: To describe clinical visual outcomes, spectacle independence, and patient satisfaction after cataract surgery with blending implantation of ReSTOR (Alcon laboratories) multifocal intraocular lenses. MATERIAL AND METHODS: A single-arm, non-randomized prospective study assessed patients undergoing cataract surgery with ReSTOR® +2.50 intraocular lens in the dominant eye and +3.00 add in the fellow eye between January 2015 to January 2020. RESULTS: In total, 47 patients (94 eyes) were enrolled, 28 women and 19 men. The average age at surgery time was 64 ±8 years, average postoperative follow-up was 45.4 ±7.0 months, with a minimum of 18.9 months. Postoperative binocular uncorrected distance visual acuity (UDVA) was on average 0.07 logMar (Snellen 20/24), uncorrected binocular intermediate visual acuity at 65 cm was 0.07 logMar (20/24), uncorrected binocular near visual acuity at 40 cm was 0.06 logMar (20/23). Contrast sensitivity under photopic and scotopic conditions, with and without glare, remained at the upper limit of normality. 98% of patients were quite satisfied or very satisfied. 87% did not require glasses for any activities, either at distant vision, nor at near vision. CONCLUSIONS: Cataract surgery with ReSTOR® IOL blended vision showed medium-term satisfactory visual results, achieving spectacle independence and a high level of satisfaction.


Assuntos
Opacificação da Cápsula , Lentes Intraoculares , Lentes Intraoculares Multifocais , Facoemulsificação , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Sensibilidades de Contraste , Implante de Lente Intraocular/métodos , Estudos Prospectivos , Satisfação do Paciente , Satisfação Pessoal , Visão Binocular , Desenho de Prótese
19.
BMC Ophthalmol ; 23(1): 157, 2023 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-37069559

RESUMO

BACKGROUND: To compare the clinical outcomes of bilateral implantation of enhanced intermediate function intraocular lenses (IOLs) and standard monofocal IOLs. METHODS: In this prospective, randomized, comparative controlled study, we compared the visual outcomes of patients who underwent bilateral cataract surgery at the Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, with either enhanced monofocal IOLs (Tecnis Eyhance, ICB00, Johnson and Johnson Vision Care, Inc) (Group 1) or standard monofocal IOLs (Tecnis, ZCB00, Johnson and Johnson Vision Care, Inc) (Group 2). The assessment included monocular and binocular uncorrected distance visual acuity (UDVA), uncorrected intermediate (UIVA at 60 cm) and near (UNVA at 40 cm) visual acuity, uncorrected defocus curves, contrast sensitivity testing (CST), and reading speed test using Quality of vision was evaluated using the Visual Function Questionnaire (VFQ-25). RESULTS: At 3-months postoperatively, monocular and binocular outcomes of UIVA and UNVA were statistically significantly better in Group 1 (P < 0.05). The binocular uncorrected defocus curve of Group 1 showed statistically significantly better outcomes at vergence ranges of -1.5 to -4.0 D (P < 0.05). Significantly higher reading speed test was also observed in Group 1 in all ranges tested (1.0 to 0.1 LogMAR) (P < 0.05). There were no statistically significant differences in CST between groups. CONCLUSIONS: Bilateral implantation of enhanced monofocal IOLs provided better vision at intermediate and near distances compared to standard monofocal IOLs, while maintaining good distance vision and contrast sensitivity.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Estudos Prospectivos , Satisfação do Paciente , Sensibilidades de Contraste , República da Coreia , Desenho de Prótese
20.
Curr Eye Res ; 48(7): 639-644, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37074213

RESUMO

PURPOSE: One common complaint with natural opacified lenses is the deleterious effects of higher-order ocular aberrations and intraocular scatter, such as halos and starbursts, which are not always remedied with surgery and intraocular lens (IOL) implantation. Blue-light filtering (BLF) IOL filter scatter-prone short-wave light. Here, we determine whether BLF IOL reduce halo and starburst size. METHODS: This study was a case-control design, between- and within-subjects (contralateral implantation). Sixty-nine participants with either the BLF IOL (n = 25; AlconSN60AT), clear IOL (n = 24; AlconSA60AT or WF), or both (n = 20) IOL participated. Participants were exposed to a point source of broadband simulated sunlight, which created the appearance of halos/starbursts. Dysphotopsia was measured as the diameter of broadband light-induced halos and starbursts. RESULTS: A case-control analysis. Halo size was significantly larger (t[35.05] = 2.98, p = 0.005) in participants with the clear control lens (M = 3°55' ± 2°48'), compared to the BLF IOL (M = 1°84' ± 1°34'). Starburst size was not significantly different between groups. Contralateral analysis. Halo size was significantly smaller (t = -3.89, p = .001) in test eyes with the BLF (M = 3°16' ± 2°35') compared to the fellow control eyes (M = 5°42' ± 3°17'). Starburst size was also significantly smaller (t = -2.60, p < 0.018) in BLF test eyes (M = 9°57' ± 4°25') than the fellow eye with the clear IOL (M = 12°33' ± 5°25'). CONCLUSIONS: BLF IOL filter short-wave light and mimic retinal screening by the young, natural crystalline lens. Such filtering can reduce some deleterious effects of bright light by decreasing ocular diffusion/halos and starbursts.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Ofuscação , Implante de Lente Intraocular , Sensibilidades de Contraste , Luz , Desenho de Prótese