Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 238
Filtrar
1.
Oral Oncol ; 125: 105682, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34998174

RESUMO

BACKGROUND: Composite flaps based on the subscapular arterial system are excellent choices for complex defects, including those of the head and neck, though rates of anatomic variants are not well described. OBJECTIVE: Characterize subscapular-thoracodorsal arterial system in a large cohort of patients using CT chest angiography. METHODS: CTA chest studies from 100 adult patients were analyzed to characterize the bilateral subscapular-thoracodorsal arterial systems. RESULTS: Out of 200 arterial systems, 25 (12.5%) were lacking a subscapular artery, with the thoracodoral and circumflex scapular arteries arising independently off of the axillary (or other nearby vessels). Strikingly, the subscapular artery was absent bilaterally in 5 patients and absent unilaterally in 15 patients, meaning that one in five patients harbored abnormal anatomy on at least one side. There was no radiographic evidence of atherosclerosis in the studied vessels in any patient, including smokers and patients with atherosclerosis in other vessels. CONCLUSION: Variations in the subscapular-thoracodorsal arterial system appear more frequent than previously described. For select patients requiring complex reconstruction using the scapular system, CTA chest may aide surgical planning.


Assuntos
Aterosclerose , Procedimentos de Cirurgia Plástica , Adulto , Artérias/anatomia & histologia , Artérias/diagnóstico por imagem , Humanos , Escápula/diagnóstico por imagem , Retalhos Cirúrgicos , Tórax/irrigação sanguínea
3.
Vasc Endovascular Surg ; 55(3): 228-233, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33308082

RESUMO

BACKGROUND: Thoracic central venous obstruction (TCVO) is a common condition which can impact the ability to achieve central venous access (CVA) in patients on hemodialysis. The Surfacer® Inside-Out® Catheter Access System is designed to enable repeated right-side central venous access in patients with TCVO. METHODS: We retrospectively analyzed medical records of 10 dialysis patients who presented with TCVO and underwent the Inside-Out procedure with the Surfacer System to obtain CVA between 2017 and 2020. Patient demographics, hemodialysis vascular access history, and procedural data were identified and analyzed. The mean patient age was 62.4 ± 19.6 years (25.9-89.1 years) with 7 of the 10 patients being male. Eight patients (80.0%) were diagnosed with chronic kidney disease with time on hemodialysis ranging from 3 to 13 years. The remaining 2 required CVA to treat acute-on-chronic kidney injury due to septic shock. Patients in our series had a mean of 2.8 ± 1.6 previous catheters placed prior to the Surfacer procedure. RESULTS: CVA was achieved in all 10 patients with 1 patient requiring a second attempt to achieve access due to the inability to initially traverse the iliac vein with the device, possibly due to a history of kidney transplantation. One multimorbid patient died shortly after the successful procedure, possibly due to cardiac decompensation. Mean total procedure time for the 7 patients having only dialysis catheter placement using the Surfacer device was 67.2 ± 19.1 minutes (49-103 minutes). The remaining 3 patients received a Hemodialysis Reliable Outflow (HeRO) graft in conjunction with the Inside-Out procedure. All vascular accesses functioned properly during the immediate time period following placement. No adverse events associated with the use of Surfacer device were encountered. CONCLUSIONS: Data presented from our patient series confirms the effectiveness of the Surfacer System to safely achieve CVA in dialysis patients with TCVOs with a history of multiple catheter placements.


Assuntos
Cateterismo Venoso Central/instrumentação , Cateteres de Demora , Cateteres Venosos Centrais , Nefropatias/terapia , Diálise Renal , Tórax/irrigação sanguínea , Doenças Vasculares/complicações , Veias , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Venoso Central/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Nefropatias/complicações , Nefropatias/diagnóstico , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Doenças Vasculares/diagnóstico por imagem , Veias/diagnóstico por imagem
4.
J Vasc Access ; 21(6): 983-989, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32372676

RESUMO

OBJECTIVE: To translate the assessment item sets of the Canadian version of the quality of life assessment, venous device-port for breast cancer patients with chest and arm ports (i.e. different implanting sites) into Chinese version, and to conduct a test of reliability and validity for it. METHODS: According to the Brislin translation model, quality of life assessment, venous device-port underwent literal and back translations, and the Chinese version of quality of life assessment, venous device-port was preliminarily revised by consulting an expert and a preliminary test. A total of 270 cancer patients undergoing chemotherapy were assessed during the use of ports, and the reliability and the validity of the Chinese version of quality of life assessment, venous device-port scale were then tested. RESULTS: The scale consisted of 23 yes/no items and seven numerical rating scales. The total Cronbach's α coefficient of the scale was 0.829, and each item ranged from 0.812 to 0.845. The item-level content validity index was 0.67-1.00, and the scale-level content validity index/average and the scale-level content validity index/universal agreement were 0.98 and 0.90, respectively. The correlation coefficient of the repeated measurement results of the scale was 0.554 (p < 0.01). Exploratory factor analysis showed that the cumulative explained variance of five common factors was 64.197%. CONCLUSION: The Chinese version of quality of life assessment, venous device-port scale is an effective assessment tool for quality of life with good reliability and validity in breast cancer patients with different implantation sites for totally implanted venous access devices in northern China.


Assuntos
Antineoplásicos/administração & dosagem , Neoplasias da Mama/tratamento farmacológico , Cateterismo Periférico/instrumentação , Qualidade de Vida , Inquéritos e Questionários , Tórax/irrigação sanguínea , Tradução , Extremidade Superior/irrigação sanguínea , Dispositivos de Acesso Vascular , Administração Intravenosa , Adulto , Idoso , Neoplasias da Mama/diagnóstico , Neoplasias da Mama Masculina/diagnóstico , Neoplasias da Mama Masculina/tratamento farmacológico , Cateterismo Periférico/efeitos adversos , China , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Resultado do Tratamento
5.
Br J Radiol ; 93(1110): 20190351, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32233939

RESUMO

OBJECTIVE: Our study aimed to compare regional node coverage and doses to the organ at risk (OAR) using conventional technique (CT) vs "AMAROS" (AT) vs intensity-modulated radiation therapy (IMRT) techniques in patients receiving regional nodal irradiation (RNI) for breast cancer (BC). METHODS: We included 30 consecutive patients with BC who received RNI including axillary nodes. Two independent and blinded dosimetric RNI plans were generated for all patients. For target volume coverage, we analyzed the V95%, the D95%, the mean and the minimal dose within the nodal station. For hotspots within nodal target volume, we used the V105%, the V108% and the maximal doses. For OAR, lung V20, mean lung and heart doses, the maximal dose to the brachial plexus and the axillary-lateral thoracic vessel junction region were compared between the three techniques. RESULTS: Target volume coverage and hotspots: Mean V95% in stations I, II, III and IV were 35.8% and 75% respectively with CV, 22.59 and 59.9% respectively with AT technique and 45.58 and 99.6% respectively with IMRT with statistically significant differences (p < 0.001). Mean V105% (cc) in axillary and supraclavicular stations were 21.3 and 6.4 respectively with CV, 1.2 and 0.02 respectively with AT technique and 0.5 and 0.4 respectively with IMRT with statistically significant differences (p < 0.001)..OARs: The mean ipsilateral lung V20 was 16.9%, 16.4 and 13.3% with CT, AT and IMRT respectively. The mean heart dose (Gy) was 0.3, 0.2 and 0.2 with CT, AT and IMRT respectively. The maximal dose to the plexus brachial (Gy) was 50.3, 46.3 and 47.3 with CT, AT and IMRT respectively. The maximal dose to the axillary-lateral thoracic vessel junction (Gy) was 52.3, 47.3 and 47.6 with CT, AT and IMRT respectively. The differences were statistically significant for all OAR (p < 0.001). CONCLUSION: AT is a valuable technique for RNI including axilla in patients with limited sentinel lymph node biopsy involvement without additional axillary lymph node dissection since it decreases hotspots in the target volume and lowers the radiation exposure of the OAR. For more advanced tumors or patients who did not respond to primary systemic therapy, CT or IMRT should be considered because of their better coverage of the potentially residual nodal disease. IMRT combines several advantages of offering high conformal plans, limited hotspots and protection of main OAR. The clinical impact of these dosimetric differences need to be addressed. ADVANCES IN KNOWLEDGE: This study is to our knowledge the first to compare conventional three-dimensional and IMRT techniques for regional nodal irradiation for each nodal station in breast cancer in a context of increasing utilization of axillary irradiation.


Assuntos
Neoplasias da Mama/radioterapia , Irradiação Linfática/métodos , Órgãos em Risco/efeitos da radiação , Radioterapia de Intensidade Modulada/métodos , Biópsia de Linfonodo Sentinela , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Axila/irrigação sanguínea , Vasos Sanguíneos/efeitos da radiação , Plexo Braquial/efeitos da radiação , Feminino , Coração/efeitos da radiação , Humanos , Pulmão/efeitos da radiação , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Tórax/irrigação sanguínea , Adulto Jovem
6.
Monaldi Arch Chest Dis ; 89(3)2019 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-31505922

RESUMO

Intercostal artery pseudoaneurysms (IAP) are extremely rare but its sudden rupture represents a life-threatening complication. We report an unusual case of a late intercostal artery pseudoaneurysm, after a video-assisted thoracoscopic surgery, presenting as a large intra-parenchymal lung mass. Diagnosis was made by biphasic computed tomography angiography and contrast-enhanced pulsed-wave doppler ultrasound. To minimize the risk of aneurysm bleeding immediate angiographic embolization was planned and successfully performed.IAP should be considered in presence of lung mass in patients who have previously undergone an intervention with intercostal approach to prevent life-threatening complications.


Assuntos
Falso Aneurisma/diagnóstico por imagem , Artérias/patologia , Cirurgia Torácica Vídeoassistida/efeitos adversos , Tórax/patologia , Idoso de 80 Anos ou mais , Falso Aneurisma/terapia , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Embolização Terapêutica/métodos , Humanos , Doença Iatrogênica , Achados Incidentais , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Tórax/irrigação sanguínea , Resultado do Tratamento , Ultrassonografia Doppler/métodos
7.
Eur J Vasc Endovasc Surg ; 57(3): 417-423, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30404722

RESUMO

OBJECTIVES: Endovascular treatment is indicated for the treatment of symptomatic thoracic central vein obstruction (TCVO) but is limited by high rates of restenosis and the need for re-intervention. The aim was to assess the safety and mid-term patency of a novel dedicated venous stent for the treatment of TCVO of benign aetiology. METHODS: This was a prospective single centre observational study of 20 patients (median age 65 years, 50% male) referred for the treatment of symptomatic chronic (>three months duration) TCVO between May 2016 and January 2018. Balloon angioplasty with implantation of a self expanding nitinol stent (Vici, Boston Scientific, Marlborough, MA, USA) was performed in all patients. Clinical records including demographics, aetiologies and types of TCVO, and procedural details were recorded. Patients were followed up clinically at one, six, and 12 months. Primary and assisted primary patency were reported. RESULTS: All 20 lesions were total occlusions, of which 55% (n = 11) were de novo, 10% (n = 2) peri-stent restenosis, and 35% (n = 7) in-stent re-occlusion. The aetiology of TCVO was predominantly (95%) because of multiple or prolonged central venous line insertion. The procedural success rate was 90% (18/20) with no procedural complications. The median follow up was 13.5 months. Primary patency was 100% at 6 months. One patient required re-intervention for stent in segment restenosis at 7 months. The assisted primary patency rate was 100% at 12 months. CONCLUSION: Endovascular treatment of benign TCVO with the novel dedicated venous stent was safe and effective in relieving obstructive symptoms with excellent one year patency rates.


Assuntos
Procedimentos Endovasculares/instrumentação , Stents Metálicos Autoexpansíveis , Tórax/irrigação sanguínea , Doenças Vasculares/cirurgia , Veias/cirurgia , Idoso , Ligas , Doença Crônica , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/etiologia , Doenças Vasculares/fisiopatologia , Grau de Desobstrução Vascular , Veias/diagnóstico por imagem , Veias/fisiopatologia
8.
J Plast Reconstr Aesthet Surg ; 72(5): 737-743, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30578046

RESUMO

BACKGROUND: Pedicled perforator flaps have progressively been used for reconstructive purposes of the anterior trunk. However, reports regarding perforator flaps for local reconstruction of the posterior trunk are sparse. The aim of this study was to investigate the vascular basis of perforator flaps based on the posterior intercostal arteries and to highlight the clinical versatility of these flaps for local posterior trunk reconstruction. METHODS: The posterior intercostal artery perforators (PICAP) between the 4th and 12th intercostal space were investigated using high resolution ultrasound in ten healthy volunteers. The location, diameter, suprafascial length and course of the individual perforators was measured. PICAP flaps were used in a series of ten cases for defect reconstruction of the posterior trunk to demonstrate their clinical versatility. RESULTS: A total number of 100 perforators was investigated. The mean diameter was 0,7 ±â€¯0,24 mm with an average length until arborisation of 0,8 ±â€¯0,8 cm. Perforators were located at 2,4 ±â€¯1,8 cm from the midline on average. Only 16% of all measured perforators were identified as major perforators (diameter ≥ 1 mm). In ten patients (mean age at surgery 61,7 years, f:m = 3:7) a PICAP flap was used for defect reconstruction at the back with a mean follow-up of 2,9 years. Flap dimensions ranged from 7 × 3 to 16 × 7 cm. In three cases, a complication was observed (one seroma, one hematoma, one marginal tip necrosis). CONCLUSION: In the present study, a reliable vascular basis of the posterior intercostal artery perforator flap could be demonstrated. Clinically these flaps replace "like with like" and may be transposed in a propeller - or V to Y - fashion. The donor site can be closed primarily in most cases, thus resulting in a favorable donor side morbidity.


Assuntos
Artérias/transplante , Retalho Perfurante/transplante , Procedimentos de Cirurgia Plástica/métodos , Tórax/irrigação sanguínea , Adulto , Idoso , Idoso de 80 Anos ou mais , Artérias/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Retalho Perfurante/irrigação sanguínea , Retalho Perfurante/patologia , Ultrassonografia
9.
Lymphology ; 51(3): 125-131, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30422435

RESUMO

Truncal lymphedema is one possible complication of breast cancer treatment. It affects many women and is diagnosed based on symptoms and clinical assessment. Because changes occur late in the process, it is useful to have a quantitative assessment that is applied earlier to detect more subtle changes and quantitively assess treatment progress. Our goal was to describe a possible method to accomplish this via measurements of tissue dielectric constant (TDC). TDC was measured at lateral thorax, anterior forearm, and biceps in 120 women awaiting surgery for breast cancer. Inter-side TDC ratios were defined as values measured on the at-risk (cancer-side) lateral thorax divided by TDC values measured on contralateral thorax, forearm, and biceps. These ratios, designated as thorax-thorax, thorax-forearm, and thorax- biceps were (mean ± SD) 1.017 ± 0.121, 1.138 ± 0.223, and 1.263 ± 0.255 respectively. Corresponding truncal lymphedema thresholds were determined by adding 2.5SD to each mean yielding thresholds of 1.32, 1.70 and 1.90. For these thresholds, 99.4% of patients would have inter-side ratios less than the threshold value. Thus, from assessments in a non-lymphedematous patient-group a set of reference threshold-ratios are now available against which patients surgically treated for breast cancer may be prospectively compared.


Assuntos
Neoplasias da Mama/cirurgia , Impedância Elétrica , Linfedema/diagnóstico , Mastectomia/efeitos adversos , Tórax/irrigação sanguínea , Feminino , Resposta Galvânica da Pele , Humanos , Linfedema/etiologia , Pessoa de Meia-Idade , Prognóstico
10.
Oral Oncol ; 75: 46-53, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29224822

RESUMO

The advent or micro-vascular free tissue transfer has facilitated the reconstruction of increasingly complex head and neck defects. There are multiple donor sites available, each with its' own advantages and disadvantages. However, the subscapular system, including the thoracodorsal system, provides the widest array of soft tissue and osseous flaps, as well as chimeric options. Its advantages include a long pedicle, independently mobile tissue components, relative sparing from atherosclerosis, and minimal donor site morbidity. The soft tissue flaps available from the thoracodorsal system include the Latissimus Dorsi, and Thoracodorsal Artery Perforator flaps, while the Tip of Scapula provides the osseous component. This review paper outlines the anatomical basis for these flaps, as well as describing their utility in head and neck reconstruction.


Assuntos
Dorso , Retalhos de Tecido Biológico , Neoplasias de Cabeça e Pescoço/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Tórax , Dorso/irrigação sanguínea , Retalhos de Tecido Biológico/irrigação sanguínea , Humanos , Tórax/irrigação sanguínea
12.
J Plast Reconstr Aesthet Surg ; 70(6): 781-791, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28259642

RESUMO

INTRODUCTION: The deep inferior epigastric perforator (DIEP) flap is a reliable and reproducible technique for autologous microsurgical breast reconstruction. Several recipient vessels sites for microvascular anastomosis have been described such as the internal thoracic vessels, the thoracodorsal vessels, and the circumflex scapular vessels. Nonetheless, the choice of the recipient site depends mainly on individual operator's experience and preferences, and currently the best recipient vessel site is under debate. This anatomical observational study aimed to determine whether anatomy could address this dilemma by determining the best vessel diameter to match the donor with these three recipient sites. METHODS: Our series reports 80 dissections of the three anatomical regions of interest. Forty formalin-preserved female cadavers were dissected bilaterally. Internal vessels diameter measurements were recorded with a vascular gauge ranging from 1.0 to 5.0 mm with successive half-millimeter graduations. RESULTS: The median diameter of the deep inferior epigastric (DIEA), internal thoracic (ITA), circumflex scapular (CSA), and thoracodorsal arteries (TDA) were: 2.0, 2.5, 2.5, and 1.5 mm, respectively. The median diameter of the deep inferior epigastric, internal thoracic, circumflex scapular, and thoracodorsal veins were: 3.0, 3.0, 3.0, and 2.5 mm, respectively. At the individual level, the perfect match between DIEA and ITA was significantly more frequent than between DIEA and TDA (p = 0.002), and it was more frequent between DIEA and CSA than between DIEA and TDA (p = 0.009). CONCLUSIONS: This study supports the use of the internal thoracic pedicle as the first recipient vessel choice, which should be considered, at least anatomically, as the best one with the closest diameter matching with the donor pedicle.


Assuntos
Mamoplastia/métodos , Microcirurgia/métodos , Retalho Perfurante/irrigação sanguínea , Artérias Torácicas/anatomia & histologia , Tórax/irrigação sanguínea , Veias/anatomia & histologia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Artérias Epigástricas/anatomia & histologia , Feminino , Humanos , Pessoa de Meia-Idade
13.
Surg Radiol Anat ; 39(1): 103-106, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27262308

RESUMO

In thoracic surgery, we occasionally encounter vessel anomalies. We herein report an extremely rare surgical case with the absence of the azygos vein. Mediastinal vascular abnormalities are said to be rare. The etiology of vascular abnormalities of the whole body, including the chest is known gene mutations, hormone abnormalities, infection, and trauma. But, many causes have been unknown. In thoracic surgery field, there is some reports and literature about pulmonary arteriovenous malformation, pulmonary sequestration, and partial anomalous pulmonary venous return. But reports about absence of azygos vein are not much. It is considered that it is less likely to become a problem in clinical. As we discussed in the paper, it will be more interesting if the association with PLSVC reveals from more cases. A 58-year-old man was admitted to our hospital in order to undergo operation for the treatment of lung cancer. We detected absence of the azygos vein by preoperative computed tomography (CT). Furthermore, three-dimensional angiography (3D-angiography) showed that the right superior intercostal vein and hemiazygos vein in the left thoracic cavity were more developed than usual. Then, we discuss the key points during surgery and suggest the potential association between the absence of the azygos vein and a persistent left superior vena cava (PLSVC).


Assuntos
Variação Anatômica , Veia Ázigos/anormalidades , Neoplasias Pulmonares/cirurgia , Tórax/irrigação sanguínea , Veia Cava Superior/anormalidades , Angiografia por Tomografia Computadorizada/métodos , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Pneumonectomia , Cuidados Pré-Operatórios/métodos , Cirurgia Torácica Vídeoassistida , Tórax/diagnóstico por imagem , Veia Cava Superior/anatomia & histologia
14.
J Vasc Access ; 17(6): 527-534, 2016 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-27768211

RESUMO

INTRODUCTION: Venous access devices are essential for the provision of care for patients requiring chemotherapy. Totally implanted venous access devices (TIVADs), also known as ports, are an option for infusion care. Medical devices have an impact upon patient quality of life. We assessed the impact on quality of life and satisfaction with their venous device, for patients with a chest TIVAD versus an upper arm TIVAD. MATERIALS AND METHODS: Sequential subjects were administered a questionnaire, "Quality of Life Assessment, Venous Device - Port (QLAVD-P)" at the time of their TIVAD removal. All subjects consented to complete the questionnaire and volunteered for this assessment. The TIVADs were all implanted and removed in the medical imaging department. RESULTS: Between March 1, 2014 and August 30, 2015, 127 subjects completed the QLAVD-P. At the time of their port removal, 51 had chest ports while 76 had arm ports. There were some negative features of the chest ports that were statistically significant in comparison to the arm ports. Most of the subjects felt that their port had a positive impact upon their treatment and they would have another port inserted if required for future treatment. DISCUSSION: Quality of life for those requiring intravenous chemotherapy is very important. This should be considered when selecting an infusion device. Venous ports were positively received by the subjects in our study and there were fewer negative impacts upon subject satisfaction and quality of life for those with upper-arm devices.


Assuntos
Antineoplásicos/administração & dosagem , Braço/irrigação sanguínea , Cateterismo Venoso Central/instrumentação , Cateterismo Periférico/instrumentação , Neoplasias/tratamento farmacológico , Satisfação do Paciente , Qualidade de Vida , Tórax/irrigação sanguínea , Dispositivos de Acesso Vascular , Adulto , Idoso , Cateterismo Venoso Central/efeitos adversos , Cateterismo Periférico/efeitos adversos , Remoção de Dispositivo , Desenho de Equipamento , Feminino , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
15.
Klin Khir ; (12): 43-5, 2016.
Artigo em Ucraniano | MEDLINE | ID: mdl-30272870

RESUMO

Videothoracoscopy constitute a secure miniinvasive method of diagnosis of intrathoracic lymphadenopathy syndrome. Pulmonary hemorrhage and injury constitute intraoperative videothoracoscopic complications, and pulmonary collapse, hemorrhage, purulent complications ­ postoperative complications. Satisfactory intraoperative visualization, guaranteeing optimal position of the patient's body on operative table and sufficient pulmonary collapse on the intervention side, application of medical аlpha­cyanacrylate adhesive with hemostatic sponge for hemostasis in a biopsy zone, systemic application of antibiotics constitute the main prophylactic methods for videothoracoscopic complications and optimization of conditions for videothoracoscopic biopsy of intrathoracic lymphatic nodes. Application of the methods proposed have permitted to reduce the intraoperative complications rate from 19.2 tо 2.8%, and a postoperative one ­ from 23 tо 2.8%.


Assuntos
Complexo Relacionado com a AIDS/cirurgia , Biópsia/efeitos adversos , Hemorragia/prevenção & controle , Linfonodos/cirurgia , Cirurgia Torácica Vídeoassistida/métodos , Complexo Relacionado com a AIDS/tratamento farmacológico , Complexo Relacionado com a AIDS/patologia , Adulto , Antibacterianos/uso terapêutico , Biópsia/instrumentação , Biópsia/métodos , Bucrilato/uso terapêutico , Feminino , Hemorragia/fisiopatologia , Humanos , Complicações Intraoperatórias/prevenção & controle , Pulmão/irrigação sanguínea , Pulmão/patologia , Pulmão/cirurgia , Linfonodos/irrigação sanguínea , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Cirurgia Torácica Vídeoassistida/instrumentação , Tórax/irrigação sanguínea , Tórax/patologia , Adesivos Teciduais/uso terapêutico
16.
Microsurgery ; 36(3): 198-205, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25732603

RESUMO

Reconstruction of the lateral malleolus or calcaneus region is challenging because of poor vascularity, minimal presence of soft tissue, and difficulties with flap positioning during and after the operation. In many cases, local flaps are limited in terms of size, durability, and vascularity. Free tissue transfer can be useful for complicated wounds. We report here on the results of the reconstruction in this region using free thoracodorsal artery perforator flaps. Between October 2010 and October 2013, 16 cases of lateral malleolus or calcaneus defects were reconstructed using free thoracodorsal artery perforator flaps. The defects varied from 2 × 5 cm(2) to 12 × 16 cm(2), and the flaps from 3 × 5 cm(2) to 10 × 15 cm(2). Two cases were reconstructed using chimeric-pattern flaps. Only the superficial adipose layers were harvested for all the flaps, without further thinning or debulking process. Five cases with complications occurred, including three cases of partial necrosis of the flap and two cases of venous congestion caused by thrombosis and compression of the venous pedicle, and one flap was totally lost. The mean follow-up duration was 11.8 months. All the patients were able to wear shoes. All but one were able to walk. The thoracodorsal artery perforator flap can be made super-thin, allowing patients to wear shoes, and it can be harvested in a chimeric-pattern for complex defects. Therefore, it may represent a viable alternative choice for the reconstruction of the lateral malleolus and calcaneus region.


Assuntos
Traumatismos do Tornozelo/cirurgia , Traumatismos do Pé/cirurgia , Retalhos de Tecido Biológico/transplante , Retalho Perfurante/transplante , Procedimentos de Cirurgia Plástica/métodos , Tórax/irrigação sanguínea , Adolescente , Adulto , Idoso , Tornozelo/cirurgia , Feminino , Seguimentos , Retalhos de Tecido Biológico/irrigação sanguínea , Calcanhar/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Retalho Perfurante/irrigação sanguínea , Adulto Jovem
17.
Microsurgery ; 35(8): 640-4, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26402745

RESUMO

OBJECTIVE: The subscapular artery has an important place in reconstructive surgery. The major pedicles of several different flaps used widely in reconstructive surgery take their roots from this arterial tree. This study aimed to provide anatomical data relating to these vessels through the use of multidetector computed tomography angiography (MDCTA) and to evaluate the clinical utility of MDCTA tool prior to surgery. METHODS AND MATERIALS: A radiological evaluation using a MDCTA was made of the bilateral subscapular arteries and branches measuring >0.5 mm in diameter that could be sufficiently identified as vascular structures in 92 patients (44 men and 48 women) with pneumonia, pleural effusion, lung masses, or nodules for which a thoracic MDCTA was requested for the purpose of diagnosis. RESULTS: The mean diameter of the subscapular artery origin was 3.86 ± 0.60 mm on the left and 3.93 ± 0.62 mm on the right. The mean diameter of the circumflex scapular artery origin was 2.41 ± 0.37 mm on the left and 2.44 ± 0.39 mm on the right. The mean diameter of the thoracodorsal artery origin was 2.29 ± 0.27 mm on the left and 2.31 ± 0.29 mm on the right. Mean length of the circumflex scapular artery was 46.34 ± 9.41 mm on the left and 46.10 ± 8.81 mm on the right. Mean length of the latissimus dorsi branch of the thoracodorsal artery from the origin of the subscapular artery was 110.11 ± 17.42 mm on the left and 112.21 ± 14.60 mm on the right. Mean length of the serratus anterior branch was 124.25 ± 19.00 mm on the left and 120.84 ± 15.67 mm on the right. No differences were detected between the left and right sides or between sexes. Doubled circumflex scapular arteries were found in 4.3% of patients, and the circumflex scapular artery branched directly off the axillary artery in 3.2% of patients. CONCLUSION: This study showed that MDCTA is a highly valuable, non-invasive imaging tool for studying vascular anatomy and detecting variations in vascular structure during preoperative planning, thus enhancing surgical safety.


Assuntos
Artérias/anatomia & histologia , Tomografia Computadorizada Multidetectores , Tórax/irrigação sanguínea , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Escápula
18.
J Vasc Interv Radiol ; 26(10): 1539-43, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26408217

RESUMO

The Loeys-Dietz syndrome is a multisystem connective tissue disorder characterized by aortopathy, arterial tortuosity, peripheral aneurysms, and skeletal features. The peripheral arteriopathy is an important cause of morbidity and potential mortality. This report presents 2 cases: the first demonstrating a 5-cm pseudoaneurysm of the right internal mammary artery and the second demonstrating a 2.3-cm aneurysm of the left internal mammary artery, each following aortic root surgery. These were successfully treated with percutaneous techniques. No complications were seen at follow-up as long as 2 years. Patients with Loeys-Dietzs syndrome require comprehensive long-term vascular follow-up and are likely to require percutaneous vascular interventions.


Assuntos
Aneurisma/etiologia , Aneurisma/cirurgia , Aorta/cirurgia , Síndrome de Loeys-Dietz/complicações , Síndrome de Loeys-Dietz/cirurgia , Enxerto Vascular/efeitos adversos , Adulto , Aneurisma/diagnóstico por imagem , Feminino , Humanos , Síndrome de Loeys-Dietz/diagnóstico por imagem , Pessoa de Meia-Idade , Radiografia , Tórax/irrigação sanguínea , Resultado do Tratamento
20.
Morphologie ; 99(327): 125-31, 2015 Dec.
Artigo em Francês | MEDLINE | ID: mdl-26159486

RESUMO

AIM: The surgical assumption of responsibility of the pancreatic pain requires either a truncular coelioscopic or radicular neurectomy of greater splanchnic nerves (gsn). The goal of our work is to describe the way and relations of the right gsn which are variable and rarely described. This constitutes an undeniable peroperational hemorrhagic risk during splanchnicectomy. MATERIAL AND METHODS: After a double side thoracotomy and a bilateral sterno-clavicular desarticulation on 15 adult cadaveric subjects preserved by method of Winckler we removed the sterno-costal drill plate as well as the ventral rib arch and proceeded to a mediastinal evisceration of the thorax. Then we respected only the thoracic aorta and the oesophagus, the azygos venous system, the thoracic duct and the thoracic sympathetic chain. In some of the subjects, the azygos vein was injected (after catheterization of its stick) using gelatine coloured with blue paint. We studied the way and vascular relations of the right gsn. We measured the transverse distances between the origin of the gsn on one hand and the longitudinal axes of the azygos vein and the thoracic duct on the other hand. RESULTS: The relations of the right gsn trunk during its way related to the azygos vein in particular its constitutive origin and its affluents: ascending lumbar vein and twelfth intercostal vein. Sometimes the thoracic duct even a lymphatic node was near the gsn in the posterior infra-mediastinal space. A classification of the way and vascular relations of the right gsn in the thorax identified 3 anatomical types. The average distances separating the right gsn on one hand from the azygos vein and the thoracic duct on the other hand were respectively 5.7 mm and 11.2 mm. CONCLUSION: The vascular relations of the right gsn are very variable from one subject to another but primarily venous, sometimes lymphatic. They concerned the great thoracic vessels whose respect is essential in particular at the time of mini-invasive access procedure for a cœlioscopic splanchnicectomy.


Assuntos
Dor Abdominal/cirurgia , Veia Ázigos/anatomia & histologia , Nervos Esplâncnicos/anatomia & histologia , Nervos Esplâncnicos/cirurgia , Tórax/irrigação sanguínea , Tórax/inervação , Adulto , Aorta Torácica/anatomia & histologia , Perda Sanguínea Cirúrgica/prevenção & controle , Cadáver , Humanos , Mediastino , Ducto Torácico/anatomia & histologia , Toracoscopia , Toracotomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA