Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Clin Physiol Funct Imaging ; 33(5): 353-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23701132

RESUMO

Several single sample methods for determination of (99m)Tc-mercaptoacetyltriglycine (MAG3) clearance are being used clinically. Kabasakal et al. proposed a similar formula for (99m)Tc-ethylenedicysteine (EC). This study was performed to compare his method with Bubeck et al. formula for (99m)Tc-MAG3 already in use. Twenty-eight subjects divided in two groups were registered which included 22 patients with various renal diseases (group-I) and six normal volunteers (group II). All subjects were studied twice using both the radiopharmaceuticals. The images and renogram parameters, that is TMAX and T1/2 of both the agents, were similar in all the subjects. The clearance of the (99m)Tc-EC was however considerably higher than (99m)Tc-MAG3 in both the groups (mean ± SEM =279 ± 14 ml min(-1)/1.73 m(2) versus 177 ± 15 ml min(-1)/1.73 m(2) in group-I and 377 ± 11.90 ml min(-1)/1.73 m(2) versus 238 ± 8.23 ml min(-1)/1.73 m(2) in group II). This difference was more pronounced in cases with reduced renal functions. Among the Effective Renal Plasma Flow (ERPF) values determined from EC and MAG3 clearances in six normal volunteers, four cases only in MAG3 had ERPF below the lower limit. This study has demonstrated superiority of single sample method for (99 m)Tc-EC clearance over its analogous method for (99m)Tc-MAG3.


Assuntos
Cisteína/análogos & derivados , Nefropatias/diagnóstico por imagem , Rim/diagnóstico por imagem , Compostos de Organotecnécio , Renografia por Radioisótopo/métodos , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Mertiatida , Adolescente , Adulto , Idoso , Estudos de Casos e Controles , Cisteína/sangue , Cisteína/farmacocinética , Feminino , Meia-Vida , Humanos , Rim/irrigação sanguínea , Rim/fisiopatologia , Nefropatias/sangue , Nefropatias/fisiopatologia , Masculino , Taxa de Depuração Metabólica , Pessoa de Meia-Idade , Compostos de Organotecnécio/sangue , Compostos de Organotecnécio/farmacocinética , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos/sangue , Compostos Radiofarmacêuticos/farmacocinética , Fluxo Plasmático Renal Efetivo , Índice de Gravidade de Doença , Tecnécio Tc 99m Mertiatida/sangue , Tecnécio Tc 99m Mertiatida/farmacocinética , Adulto Jovem
2.
Arch. med. res ; 30(1): 49-54, ene.-feb. 1999. tab, graf
Artigo em Inglês | LILACS | ID: lil-256620

RESUMO

Background. Technetium-99m-mercaptoacetyltriglycine (99-mTc-MAG3) is a radiopharmaceutical for tubular function and can be prepared with 99-mtechnetium and the ligand Bz-MAG3 (Instituto Nacional de Investigaciones Nucleares, Mexico City). No radiopharmacokinetic parameters have been found for the healty adult Mexican population with 99mTc-MAG3, prepared with the nationally produced or imported Bz-MAG3 kit. Methods. The radiopharmacokinetic parametrs and the clearance of 99mTc-Mag3 in seven healthy Mexican volunteers were determined by the single-and multi-sample methods. Computer programs were used for the calculations. Results. Using several plasma samples from 0.43 min and the BIEXP program, it was show that 99mTc-MAG3 follows a two-compartment model of distribution, with an apparent volumen in the central compartment Vdcc = 6.7 + 1.0 1, T½Ó = 0.07 + 0.02 h-1, T½ ß = 0.49 + 0.15 h-1, mean residence time MRT = 0.60 + 0.17 h and clearance = 208 57 (ml/min)/1.73 m². In comparison, the clearance value with a single sample drawn 43 min post-injection and calculated with Tauxe's formula was 193 ñ 59 (ml/min)/m². Conclusions. The 15 ml difference between the two methods is neither statistically different (p= 0.11) nor important for routine clinical studies. The single-sample method is recommendad because it is reliable and can be done at the same time that dynamic renal scan is aquiered. Estimated absorbed radiation dose was calvulated for several organs


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Mertiatida/farmacocinética , Doses de Radiação , Radiometria , Tecnécio Tc 99m Mertiatida/sangue , Testes de Função Renal , Distribuição Tecidual
3.
Nucl Med Commun ; 18(4): 352-7, 1997 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9170621

RESUMO

The aim of this study was to assess the intra-individual reproducibility of 99Tcm-mercaptoacetyltriglycine (99Tcm-MAG3) clearance in routine clinical practice in various circumstances using a single-sample method. Three groups of 30 patients each were enrolled in the study. Investigations were repeated on the same day with two different levels of activity (group A), within 1 week (group B), or after 1 year (group C). Blood samples were taken after 20 and 25 min and clearance values were averaged to minimize incidental errors after calculation according to the formula proposed by Bubeck et al. For clearance estimation on the same day, time-dependent background correction for residual activity was carried out. The mean difference was -2.0%, +6.0% and -1.5% (S.D. = 6.3%, 15.7% and 11.7%) for groups A, B and C respectively, taking into account values > 100 ml min-1 only. We demonstrated that 99Tcm-MAG3 clearance is highly reproducible under the same conditions. However, a repeat clearance measurement on a separate day revealed large differences. Therefore, in follow-up studies for evaluation of changing kidney function (e.g. surgery or chemotherapy), differences should exceed 30% (i.e. 2 S.D. of group B) to be statistically significant.


Assuntos
Tecnécio Tc 99m Mertiatida/farmacocinética , Taxa de Filtração Glomerular , Humanos , Injeções Intravenosas , Rim/fisiologia , Rim/fisiopatologia , Taxa de Depuração Metabólica , Reprodutibilidade dos Testes , Tecnécio Tc 99m Mertiatida/administração & dosagem , Tecnécio Tc 99m Mertiatida/sangue , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA