Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Surgery ; 171(1): 55-62, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34340823

RESUMO

BACKGROUND: Primary hyperparathyroidism historically necessitated bilateral neck exploration to remove abnormal parathyroid tissue. Improved localization allows for focused parathyroidectomy with lower complication risks. Recently, positron emission tomography using radiolabeled 18F-fluorocholine demonstrated high accuracy in detecting these lesions, but its cost-effectiveness has not been studied in the United States. METHODS: A decision tree modeled patients who underwent parathyroidectomy for primary hyperparathyroidism using single preoperative localization modalities: (1) positron emission tomography using radiolabeled 18F-fluorocholine, (2) 4-dimensional computed tomography, (3) ultrasound, and (4) sestamibi single photon emission computed tomography (SPECT). All patients underwent either focused parathyroidectomy versus bilateral neck exploration, with associated cost ($) and clinical outcomes measured in quality-adjusted life-years gained. Model parameters were informed by literature review and Medicare costs. Incremental cost-utility ratios were calculated in US dollars/quality-adjusted life-years gained, with a willingness-to-pay threshold set at $100,000/quality-adjusted life-year. One-way, 2-way, and threshold sensitivity analyses were performed. RESULTS: Positron emission tomography using radiolabeled 18F-fluorocholine gained the most quality-adjusted life-years (23.9) and was the costliest ($2,096), with a total treatment cost of $11,245 or $470/quality-adjusted life-year gained. Sestamibi single photon emission computed tomography and ultrasound were dominated strategies. Compared with 4-dimentional computed tomography, the incremental cost-utility ratio for positron emission tomography using radiolabeled 18F-fluorocholine was $91,066/quality-adjusted life-year gained in our base case analysis, which was below the willingness-to-pay threshold. In 1-way sensitivity analysis, the incremental cost-utility ratio was sensitive to test accuracy, positron emission tomography using radiolabeled 18F-fluorocholine price, postoperative complication probabilities, proportion of bilateral neck exploration patients needing overnight hospitalization, and life expectancy. CONCLUSION: Our model elucidates scenarios in which positron emission tomography using radiolabeled 18F-fluorocholine can potentially be a cost-effective imaging option for primary hyperparathyroidism in the United States. Further investigation is needed to determine the maximal cost-effectiveness for positron emission tomography using radiolabeled 18F-fluorocholine in selected populations.


Assuntos
Análise Custo-Benefício/estatística & dados numéricos , Hiperparatireoidismo Primário/diagnóstico , Glândulas Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/diagnóstico , Tomografia por Emissão de Pósitrons/economia , Colina/administração & dosagem , Colina/análogos & derivados , Colina/economia , Radioisótopos de Flúor/administração & dosagem , Radioisótopos de Flúor/economia , Tomografia Computadorizada Quadridimensional/economia , Humanos , Hiperparatireoidismo Primário/economia , Hiperparatireoidismo Primário/etiologia , Hiperparatireoidismo Primário/cirurgia , Medicare/economia , Medicare/estatística & dados numéricos , Modelos Econômicos , Glândulas Paratireoides/patologia , Glândulas Paratireoides/cirurgia , Neoplasias das Paratireoides/complicações , Neoplasias das Paratireoides/economia , Neoplasias das Paratireoides/cirurgia , Paratireoidectomia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/economia , Tomografia por Emissão de Pósitrons/métodos , Cuidados Pré-Operatórios/economia , Cuidados Pré-Operatórios/métodos , Anos de Vida Ajustados por Qualidade de Vida , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/economia , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi/administração & dosagem , Tecnécio Tc 99m Sestamibi/economia , Ultrassonografia/economia , Estados Unidos
2.
AJR Am J Roentgenol ; 204(6): 1345-53, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26001247

RESUMO

OBJECTIVE: The purpose of this study was to examine additional diagnostic workup and costs generated by addition of a single molecular breast imaging (MBI) examination to screening mammography for women with dense breasts. SUBJECTS AND METHODS: Women with mammographically dense breasts presenting for screening mammography underwent adjunct MBI performed with 300 MBq (99m)Tc-sestamibi and a direct-conversion cadmium-zinc-telluride dual-head gamma camera. All subsequent imaging tests and biopsies were tracked for a minimum of 1 year. The positive predictive value of biopsies performed (PPV3), benign biopsy rate, cost per patient screened, and cost per cancer detected were determined. RESULTS: A total of 1651 women enrolled in the study. Among the 1585 participants with complete reference standard, screening mammography alone prompted diagnostic workup of 175 (11.0%) patients and biopsy of 20 (1.3%) and yielded five malignancies (PPV3, 25%). Results of combined screening mammography plus MBI prompted diagnostic workup of 279 patients (17.6%) and biopsy of 67 (4.2%) and yielded 19 malignancies (PPV3, 28.4%). The benign biopsy rates were 0.9% (15 of 1585) for screening mammography alone and 3.0% (48 of 1585) for the combination (p < 0.001). The addition of MBI increased the cost per patient screened from $176 for mammography alone to $571 for the combination. However, cost per cancer detected was lower for the combination ($47,597) than for mammography alone ($55,851). CONCLUSION: The addition of MBI to screening mammography of women with dense breasts increased the overall costs and benign biopsy rate but also increased the cancer detection rate, which resulted in a lower cost per cancer detected than with screening mammography alone.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/economia , Detecção Precoce de Câncer/economia , Custos de Cuidados de Saúde/estatística & dados numéricos , Mamografia/economia , Imagem Molecular/economia , Tomografia por Emissão de Pósitrons/economia , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Prevalência , Compostos Radiofarmacêuticos/economia , Tecnécio Tc 99m Sestamibi/economia , Estados Unidos/epidemiologia
3.
Am J Surg ; 207(5): 698-701; discussion 701, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24791629

RESUMO

BACKGROUND: Both MRI and breast-specific gamma imaging are tools for surgical planning in newly diagnosed breast cancer. Breast-specific gamma imaging (BSGI) is used less frequently although it is of similar utility and lower cost. We compared the diagnostic and cost efficacy of BSGI with MRI. METHODS: Retrospective review of 1,480 BSGIs was performed in a community breast health center, 539 had a new diagnosis of cancer, 75 patients having both MRI and BSGI performed within 2 months of each other. Institutional charges for BSGI ($850) and MRI ($3,381) were noted. RESULTS: BSGI had a sensitivity of 92%, specificity of 73%, positive predictive value of 78%, and negative predictive value of 90%. This compared favorably with MRI that had sensitivity of 89%, specificity 54%, positive predictive value 67%, and negative predictive value 83%. The accuracy of BSGI was higher at 82% vs MRI at 72%. Total cost of MRI imaging was $253,575 vs BSGI at $63,750. CONCLUSIONS: BSGI is a cost-effective and accurate imaging study for further evaluation of dense breast tissue and new diagnosis of cancer.


Assuntos
Neoplasias da Mama/diagnóstico , Raios gama , Preços Hospitalares/estatística & dados numéricos , Imageamento por Ressonância Magnética/economia , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Neoplasias da Mama/economia , Análise Custo-Benefício , Feminino , Humanos , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos/economia , Estudos Retrospectivos , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi/economia
4.
J Med Assoc Thai ; 96(10): 1350-64, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24350419

RESUMO

OBJECTIVE: To evaluate cost-effectiveness analysis of 18F-FDG PET/CT to detect tumor recurrence or metastasis in well-differentiated thyroid cancer patients with high Tg but negative TBS in Thailand. MATERIAL AND METHOD: A retrospective literature review of 55 studies published between 1978 and 2010 was done. Decision analysis by TreeAge program showed an evaluation of the most cost-effective treatment and 18F-FDG PET/CT scan in thyroid cancer patients with high Tg but negative TBS. The incremental cost and life years gained associated with seven strategies approached were analyzed by the decision tree model. The first strategy was treatment with empirical high dose 131I therapy. The second to the seventh strategies were using imaging investigations by CT scan of neck and chest, 99mTc MIBI scan, and 18F-FDG PET/CT scan to identify recurrent, persistent, and metastatic lesions before the specific treatment via curative surgery, external radiotherapy, and high dose 131I therapy. All strategies were adopted using hospital perspective and direct medical cost was estimated based on the reference price of Siriraj Hospital. Deterministic sensitivity analysis was conducted to investigate the effect of the cost of PET/CT scan. RESULTS: The strategy using 18F-FDG PET/CT scan to detect recurrence or metastasis and possible curative surgery in operable cases and high dose 131I therapy in inoperable cases gave the highest life years gained of 27.08 with cost of 90,227.61 Baht (2,926.24 US dollars) and acceptable incremental cost effectiveness ratio (ICER) of 6,936.88 Baht (224.98 US dollars) per life year gained when compared to the least costly strategy using 99mTc MIBI scan and additional 18F-FDG PET/CT scan in negative MIBI result. Other strategies were dominated by this PET/CT strategy. Deterministic sensitivity analysis (based on the willingness to pay (WTP) 360,000 Baht (11,675.42 US dollars) showed that the cost of PET/CT scan has no impact on the net health benefit. CONCLUSION: Based on the hospital perspective, the cost-effectiveness of 18F-FDG PET/CT scan in detecting suspected recurrence or metastasis in thyroid carcinoma patients with negative diagnostic TBS but high Tg was first done using 18F-FDG PET/CT scan to identify disease, followed by curative surgery or high dose 131I therapy. Moreover cost of PET/CT scan did not influence the net health benefit. This PET/CT benefit is helpfulfor considering the proper PET/CT use for thyroid cancer in Thailand.


Assuntos
Árvores de Decisões , Fluordesoxiglucose F18/economia , Imagem Multimodal/economia , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/economia , Compostos Radiofarmacêuticos/economia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Imagem Corporal Total/economia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Análise Custo-Benefício , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Tecnécio Tc 99m Sestamibi/economia , Tailândia , Neoplasias da Glândula Tireoide/patologia
5.
JAMA Surg ; 148(6): 500-3, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23575888

RESUMO

IMPORTANCE: Dynamic computed tomography (CT) is emerging as a first-line alternative to sestamibi scintigraphy for preoperative localization of parathyroid lesions. In recent years, there has been increased concern over the impact of radiation exposure from medical imaging, as well as on the cost of diagnostic medical procedures. An ideal diagnostic procedure would be cost effective while minimizing hazardous exposures and complication rates. OBJECTIVE: To compare the radiation dose and financial cost of dynamic CT with sestamibi scintigraphy. DESIGN, SETTING, AND PATIENTS: A retrospective review of 263 patients at a large, urban, tertiary referral center who underwent either dynamic parathyroid CT or sestamibi scintigraphy for any etiology of hyperparathyroidism from 2006 through 2010. MAIN OUTCOMES AND MEASURES: The 2 primary study outcomes were radiation exposure measured in millisieverts (mSv) and medical charges for the respective diagnostic procedures. The study was conducted with the hypothesis that dynamic parathyroid CT would have slightly greater radiation exposure with similar cost to sestamibi scintigraphy. RESULTS: Dynamic parathyroid CT and sestamibi scintigraphy delivered mean radiation doses of 5.56 and 3.33 mSv, respectively (P < .05). Charges totaled $1296 for thin-cut dynamic parathyroid CT and a mean of $1112 for sestamibi scintigraphy, depending on the type and amount of radiotracer injected. Although multiphase CT scanning took less than 5 minutes, sestamibi scintigraphy lasted a mean time of 306 minutes. A total of 62 of 119 patients (52%) in the CT group have undergone operative treatment to date, whereas all patients in the sestamibi arm underwent operative treatment of their hyperparathyroidism. Of the patients who underwent a surgical procedure, CT correctly identified the side of the parathyroid adenoma in 54 of 62 patients (87%), while sestamibi scintigraphy only correctly lateralized 90 of 122 adenomas (74%) as confirmed by exploratory surgery, intraoperative parathyroid hormone levels, and pathologic features. A dynamic parathyroid CT correctly predicted multiglandular disease in 1 of 7 patients (14%), while sestamibi scintigraphy correctly predicted multiglandular disease in 8 of 23 patients (35%). CONCLUSIONS AND RELEVANCE: In patients who underwent directed parathyroid surgery, dynamic CT is comparable to sestamibi scintigraphy in patients with hyperparathyroidism. Although CT delivers a higher dose of radiation, the average background radiation exposure in the United States is 3 mSv/y, and added exposures of less than 15 mSv are considered low risk for carcinogenesis. Overall, dynamic parathyroid CT is a safe, cost-effective alternative to sestamibi scintigraphy.


Assuntos
Adenoma/diagnóstico por imagem , Neoplasias das Paratireoides/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada por Raios X/economia , Adenoma/economia , Efeitos Psicossociais da Doença , Análise Custo-Benefício , Feminino , Humanos , Hiperparatireoidismo/cirurgia , Masculino , Pessoa de Meia-Idade , Glândulas Paratireoides/cirurgia , Neoplasias das Paratireoides/economia , Cuidados Pré-Operatórios , Doses de Radiação , Cintilografia , Compostos Radiofarmacêuticos/economia , Estudos Retrospectivos , Tecnécio Tc 99m Sestamibi/economia , Tomografia Computadorizada por Raios X/métodos
6.
Surgery ; 150(6): 1286-94, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22136852

RESUMO

BACKGROUND: Minimally invasive parathyroidectomy for primary hyperparathyroidism depends on accurate preoperative localization. This study examines the cost-utility of sestamibi in combination with single photon emission computed tomography (sestamibi-SPECT); ultrasound; and 4-dimensional computed tomography (4D-CT). METHODS: A decision tree was constructed for patients undergoing initial parathyroidectomy. Patients were randomized to 1 of 5 preoperative localization protocols: (1) ultrasound; (2) sestamibi-SPECT; (3) 4D-CT; (4) sestamibi-SPECT and ultrasound; and (5) sestamibi-SPECT and ultrasound and 4D-CT, if discordant (sestamibi-SPECT and ultrasound ± 4D-CT). From a societal perspective, all relevant costs were included. Input data were obtained from literature and Medicare. The incremental cost-utility ratio was determined in dollars per quality-adjusted life years ($/QALY). Sensitivity analyses were performed. RESULTS: In the base-case, ultrasound was least expensive, with a cost of $6666, compared to $6773 (4-D CT); $7214 (sestamibi-SPECT and ultrasound ± 4D-CT); $7330 (sestamibi-SPECT); and $7371(sestamibi-SPECT and ultrasound). Sestamibi-SPECT and ultrasound ± 4D-CT were most cost-effective because improved localization resulted in fewer bilateral explorations. QALY were comparable across modalities. Compared to sestamibi-SPECT, ultrasound, 4D- CT, and sestamibi-SPECT and ultrasound ± 4D-CT resulted a win-win situation-costing less and accruing more utility. Sensitivity analyses demonstrated that the model was sensitive to surgery cost and diagnostic accuracy of imaging. CONCLUSION: In our model, sestamibi-SPECT and ultrasound ± 4D-CT were the most cost-effective methods, followed by 4D-CT and ultrasound. Sestamibi-SPECT alone was least cost-effective. Cost-utilities were dependent on the sensitivities of ultrasound and 4D-CT and may vary by institution.


Assuntos
Tomografia Computadorizada Quadridimensional/economia , Hiperparatireoidismo Primário/diagnóstico , Paratireoidectomia , Cuidados Pré-Operatórios/economia , Tomografia Computadorizada de Emissão de Fóton Único/economia , Ultrassonografia/economia , Algoritmos , Análise Custo-Benefício , Árvores de Decisões , Custos de Cuidados de Saúde , Humanos , Hiperparatireoidismo Primário/economia , Hiperparatireoidismo Primário/cirurgia , Modelos Econômicos , Anos de Vida Ajustados por Qualidade de Vida , Compostos Radiofarmacêuticos/economia , Tecnécio Tc 99m Sestamibi/economia , Estados Unidos
7.
J Nucl Med ; 50(3): 376-81, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19223414

RESUMO

UNLABELLED: Multidrug resistance (MDR) is a major problem in lung cancer. (99m)Tc-methoxyisobutylisonitrile ((99m)Tc-MIBI) has been demonstrated to be a noninvasive marker for the diagnosis of MDR-related P glycoprotein and MDR-associated protein expression in various solid tumors. Studies have shown that (99m)Tc-MIBI could play a significant role in the management of lung cancer; for example, it could be used in the selection of patients for chemotherapy or radiotherapy or in combined protocols before the start of treatment. Accurate selection of chemosensitive patients with (99m)Tc-MIBI would result not only in effective treatment of patients but also in significant cost savings for health care providers. There is increasing pressure on health care providers to consider costs in medical decision making, particularly in the last decade, as several economic evaluations have appeared in the medical literature. The aims of this study were to undertake a systematic review of the performance of (99m)Tc-MIBI imaging in the assessment of treatment resistance in lung cancer and to use the findings of the review in a decision tree analysis of the potential cost-effectiveness of (99m)Tc-MIBI imaging in selecting lung cancer patients for chemotherapy. METHODS: This study included a systematic review of the literature and a meta-analysis together with a cost-effectiveness analysis of studies with a decision tree analysis model. RESULTS: Analysis of the studies revealed that the overall sensitivity of (99m)Tc-MIBI in identifying responders to chemotherapy was 94%, the specificity was 90%, and the accuracy was 92%. The sensitivity analysis revealed an incremental cost-effectiveness ratio of greater than pound30,000 ( approximately $42,900) for the strategy of treating all patients to recover the small loss of life expectancy (7.5 d) associated with the use of (99m)Tc-MIBI to preselect patients for chemotherapy. CONCLUSION: (99m)Tc-MIBI SPECT can accurately predict which patients with lung cancer will respond to chemotherapy. The use of (99m)Tc-MIBI to preselect patients for chemotherapy has the potential to yield significant cost savings in the health care system without a significant loss of life expectancy for patients.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/economia , Compostos Radiofarmacêuticos/economia , Tecnécio Tc 99m Sestamibi/economia , Análise Custo-Benefício , Árvores de Decisões , Resistencia a Medicamentos Antineoplásicos , Humanos , Neoplasias Pulmonares/tratamento farmacológico , Tomografia Computadorizada de Emissão de Fóton Único , Resultado do Tratamento
9.
Otolaryngol Clin North Am ; 37(4): 855-70, x-xi, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15262521

RESUMO

This article presents a cost-effectiveness analysis to determine whether preoperative imaging with Tc99m-sestamibi for detection and treatment of solitary adenomas associated with primary hyperparathyroidism is cost-effective compared with routine bilateral neck exploration.


Assuntos
Hiperparatireoidismo/cirurgia , Glândulas Paratireoides/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Análise Custo-Benefício , Humanos , Hiperparatireoidismo/diagnóstico por imagem , Hiperparatireoidismo/economia , Pescoço/cirurgia , Glândulas Paratireoides/patologia , Paratireoidectomia , Cintilografia , Compostos Radiofarmacêuticos/economia , Tecnécio Tc 99m Sestamibi/economia
10.
Surg Oncol ; 11(3): 151-5, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12356511

RESUMO

In general, biopsy is the preferred management method for women with indeterminate mammographically dense breasts. In this review, we describe a decision analysis model comparing technetium-99m methoxyisobutylisonitrile (Tc-99m sestamibi) scintimammography and excisional biopsy as breast cancer evaluation strategies for hypothetical cohorts of estimated 16,000-40,000 women with indeterminate mammographic probability of malignancy because of mammographically dense breasts. In cost-effectiveness analysis, quantitative decision tree sensitivity analysis was used to compare the conventional excision biopsy alone strategy (strategy A) with decision strategy for screening with Tc-99m sestamibi scintimammography before excision biopsy (strategy B) after an indeterminate mammogram. Strategy B showed a cost saving of US dollars 649,600-1,624,000 in reducing the cost of unnecessary biopsies. The total cost of strategy B showed a cost saving of US dollars 123,075-307,776 compared to strategy A. The analysis data indicate that Tc-99m sestamibi scintimammography can save the cost of unnecessary biopsies in Taiwanese women with non-diagnostic mammogram because of mammographically dense breasts.


Assuntos
Biópsia/economia , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/economia , Compostos Radiofarmacêuticos/economia , Tecnécio Tc 99m Sestamibi/economia , Biópsia/métodos , Neoplasias da Mama/cirurgia , Análise Custo-Benefício , Árvores de Decisões , Feminino , Humanos , Mamografia , Taiwan
11.
Arch Surg ; 137(8): 917-22; discussion 922-3, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12146990

RESUMO

HYPOTHESIS: Preoperative and intraoperative localizing techniques are more cost-effective than a nondirected bilateral neck exploration in the initial treatment of primary hyperparathyroidism (HPT). DESIGN: A clinical outcome model was developed to simulate the surgical management of primary HPT. Clinical scenarios modeled included a nondirected bilateral neck exploration and surgery using the following localizing strategies: preoperative technetium Tc 99m sestamibi scanning, intraoperative "quick" intact parathyroid hormone assay, or intraoperative radioguidance. Average total charges based on intent to treat were estimated from our practice and from the literature. MAIN OUTCOME MEASURES: Average total charges per patient (for the primary operation and for reexploration for persistent HPT, if needed), incidence of surgical failure (ie, persistent HPT), and risk of recurrent laryngeal nerve injury (cumulative risk of the primary procedure and a subsequent operation for persistent HPT). RESULTS: The use of any localizing strategy reduced total charges, risk of persistent HPT, and cumulative risk of recurrent laryngeal nerve injury compared with a nondirected bilateral neck exploration. The greatest cost savings and the lowest risk of recurrent laryngeal nerve injury were achieved when technetium Tc 99m sestamibi scanning was combined with intraoperative radioguidance. The lowest rate of persistent HPT was found when technetium Tc 99m sestamibi scanning was combined with an intraoperative parathyroid hormone assay. CONCLUSIONS: Limited parathyroid surgery using any localizing strategy is cost-effective, safe, and efficacious in the management of primary HPT. The cost benefit was primarily achieved by reduced operative charges and immediate hospital discharge rather than a lower need for reexploration for persistent HPT.


Assuntos
Hiperparatireoidismo/economia , Hiperparatireoidismo/cirurgia , Paratireoidectomia/economia , Redução de Custos , Análise Custo-Benefício , Humanos , Hiperparatireoidismo/diagnóstico , Complicações Intraoperatórias/economia , Período Intraoperatório , Pescoço/cirurgia , Glândulas Paratireoides/diagnóstico por imagem , Hormônio Paratireóideo/sangue , Cintilografia , Compostos Radiofarmacêuticos/economia , Traumatismos do Nervo Laríngeo Recorrente , Reoperação , Fatores de Risco , Tecnécio Tc 99m Sestamibi/economia , Falha de Tratamento
12.
Nucl Med Commun ; 23(3): 203-8, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11891477

RESUMO

The purpose of this investigation was to compare the efficiency of two different imaging protocols using two different clinically available 99mTc labelled myocardial perfusion tracers. One thousand one hundred and thirty-four imaging studies were performed prospectively, using either 99mTc-tetrofosmin or 99mTc-sestamibi, alternating the use of each tracer for a total period of 8 months. 99mTc-tetrofosmin rest studies were performed with injections of 259MBq-370MBq and imaging 30 min later. Exercise studies were performed with injections of 777MBq-1.11GBq and imaging 20 min later. 99mTc-sestamibi studies used doses similar to those in the 99mTc-tetrofosmin studies. Imaging followed a standard procedure, at 60 min after rest injection, and 30 min after exercise. For patients undergoing pharmacological stress testing99mTc-sestamibi was imaged 45 min after injection and 99mTc-tetrofosmin was imaged 30 min after injection. Variables analysed were (1) injection-to-imaging time for the procedure, and (2) the number of repeated scans because of extra cardiac activity. The completion time for the rest study was significantly shorter for 99mTc-tetrofosmin compared to 99mTc-sestamibi (47.7+/-21.7 min vs 74.3+/-25.8 min P<0.0001). Likewise, the total study time was shorter for 99mTc-tetrofosmin compared to 99mTc-sestamibi (90+/-32.7 min vs 124+/-37 min, P<0.0001). More importantly, the number of repeated scans was higher with 99mTc-sestamibi compared to 99mTc-tetrofosmin, 21.4% vs 10%, P=0.001 for rest studies and 16.4% vs 7.9% P=0.001 [corrected] for rest and stress. It was concluded that, using a same day rest/stress protocol, 99mTc-tetrofosmin provided higher patient throughput with fewer repeat scans. These factors may be considered for efficiency improvement in nuclear cardiology laboratories using 99mTc perfusion tracers.


Assuntos
Adenosina , Isquemia Miocárdica/diagnóstico por imagem , Compostos Organofosforados , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Teste de Esforço/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/metabolismo , Compostos Organofosforados/administração & dosagem , Compostos Organofosforados/economia , Compostos Organofosforados/farmacocinética , Compostos de Organotecnécio/administração & dosagem , Compostos de Organotecnécio/economia , Compostos de Organotecnécio/farmacocinética , Estudos Prospectivos , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/economia , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi/administração & dosagem , Tecnécio Tc 99m Sestamibi/economia , Tecnécio Tc 99m Sestamibi/farmacocinética , Fatores de Tempo , Tomografia Computadorizada de Emissão de Fóton Único
13.
Q J Nucl Med ; 44(2): 168-85, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10967626

RESUMO

BACKGROUND: The purpose of this study was to assess if breast cancer screening using sestamibi scintimammography (SSMM) in conjunction with mammography (MM) is cost effective in avoiding biopsies in healthy patients. METHODS: Quantitative decision tree sensitivity analysis was used to compare the conventional MM alone strategy (strategy A) with two decision strategies for screening with SSMM; SSMM after an indeterminate mammogram (strategy B) or SSMM after both a positive and an indeterminate mammogram (strategy C). Cost effectiveness was measured by calculating the expected cost per patient and the average life expectancy per patient for baseline values as well as over a range of values for all of the variables of each strategy. RESULTS: Based on Medicare reimbursement values, strategies B and C showed a cost savings of $9 and $20 per patient respectively as compared to strategy A. This translates into respective savings of $189 and $420 million per year assuming 21 million females undergo screening each year. Strategies B and C did however have a loss of mean life expectancy of 0.000178 and 0.000222 years respectively as compared to strategy A due to interval progression of breast cancer in a small number of women. Strategies B and C significantly lowered the number of biopsies performed on healthy patients in the screening population by 750,063 and 1,557,915 biopsies respectively as compared to strategy A. CONCLUSIONS: These results quantitatively verify the potential utility of using SSMM in avoiding unnecessary biopsies.


Assuntos
Biópsia/economia , Neoplasias da Mama/diagnóstico por imagem , Técnicas de Apoio para a Decisão , Programas de Rastreamento/economia , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Neoplasias da Mama/economia , Redução de Custos , Análise Custo-Benefício , Custos e Análise de Custo , Árvores de Decisões , Progressão da Doença , Feminino , Custos de Cuidados de Saúde , Humanos , Reembolso de Seguro de Saúde/economia , Expectativa de Vida , Mamografia/economia , Medicare/economia , Cintilografia , Compostos Radiofarmacêuticos/economia , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi/economia , Estados Unidos , Procedimentos Desnecessários/economia
14.
Surgery ; 126(6): 1036-40; discussion 1040-1, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10598185

RESUMO

BACKGROUND: Sestamibi-guided limited neck explorations are an alternative to the standard bilateral neck exploration for patients with primary hyperparathyroidism. A recently published meta-analysis by Denham and Norman (JACS vol.186, 1998) suggested that a sestamibi-directed approach offers a cost benefit because it decreases operative and recovery room times, hospital stay, and the number of frozen sections needed. METHODS: We reviewed 41 bilateral neck explorations for primary hyperparathyroidism and compared our results with those reported by the meta-analysis to determine whether a sestamibi-directed approach is cost effective. RESULTS: Operative and recovery room times averaged 60.3 +/- 19.3 and 45 minutes, respectively. Forty six percent of the patients were treated as outpatients, and 1.21 +/- 0.57 frozen sections were obtained per case. Our standard bilateral exploration cost 47% less than the bilateral approach and 17% less than the sestamibi-directed operation calculated in the meta-analysis. There were no cases of nerve injury or permanent hypocalcemia, 98% of patients were cured, and 61% of patients did not require narcotics postoperatively. CONCLUSIONS: Sestamibi-guided parathyroidectomy may not offer any advantage over the standard bilateral exploration. In our experience, a bilateral neck exploration can be performed on an outpatient basis and at low cost, with a high success rate and minimal morbidity. Most patients do not require narcotics, and the cosmetic results are excellent.


Assuntos
Hiperparatireoidismo/diagnóstico por imagem , Hiperparatireoidismo/cirurgia , Paratireoidectomia/economia , Tecnécio Tc 99m Sestamibi/economia , Procedimentos Cirúrgicos Ambulatórios/economia , Análise Custo-Benefício , Seguimentos , Secções Congeladas/economia , Custos Hospitalares , Humanos , Hiperparatireoidismo/economia , Paratireoidectomia/métodos , Satisfação do Paciente , Cintilografia
16.
J Am Coll Surg ; 186(3): 293-305, 1998 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9510260

RESUMO

BACKGROUND: In 1991, a National Institutes of Health Consensus Panel stated that preoperative localization for primary hyperparathyroidism is not cost effective. Since then, the sestamibi scan has been applied to parathyroid disease with excellent results, even allowing unilateral exploration under local anesthesia. STUDY DESIGN: A metaanalysis of the English literature over the past 10 years was performed to determine the collective sensitivity and specificity of sestamibi scanning to establish its utility in directing a unilateral procedure. The cost effectiveness of scanning all patients with sporadic primary hyperparathyroidism was examined by determining the costs of seven operative technique-dependent variables that could be reduced with a limited procedure. RESULTS: The average sensitivity and specificity of sestamibi were 90.7% and 98.8%, respectively, indicating its ability to guide an accurate unilateral exploration. The analysis of 6,331 patients showed that 87% had solitary adenomas. An average cost savings of $650 was demonstrated for a unilateral operation, which could be realized in as many as 90% (sestamibi sensitivity) of those with solitary adenomas. CONCLUSIONS: A preoperative sestamibi scan is specific enough in identifying solitary adenomas to allow unilateral exploration with a < 1% failure rate. The sensitivity of this scan suggests that 78% of all patients with sporadic primary hyperparathyroidism (90% of the 87% with solitary adenomas) are candidates for unilateral exploration. This rate is significantly higher than the 51% rate at which scanning all patients becomes cost effective.


Assuntos
Hiperparatireoidismo/diagnóstico por imagem , Hiperparatireoidismo/cirurgia , Paratireoidectomia/métodos , Compostos Radiofarmacêuticos/economia , Tecnécio Tc 99m Sestamibi/economia , Adenoma/diagnóstico por imagem , Adenoma/economia , Adenoma/cirurgia , Análise Custo-Benefício , Humanos , Hiperparatireoidismo/economia , Neoplasias das Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/economia , Neoplasias das Paratireoides/cirurgia , Seleção de Pacientes , Cuidados Pré-Operatórios/economia , Cintilografia , Sensibilidade e Especificidade
17.
Am Surg ; 63(12): 1097-100; discussion 1100-1, 1997 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9393259

RESUMO

Tc-99m-sestamibi has been shown to localize parathyroid adenomas effectively, but controversy continues as to the use of this scan before initial surgery for primary hyperparathyroidism. We analyzed the cost utility of obtaining this study before initial surgery for primary hyperparathyroidism. Twenty-two consecutive patients with primary hyperparathyroidism underwent dual-phase Tc-99m-sestamibi scan before initial bilateral neck exploration. Surgical findings were correlated with the results of sestamibi scan. There were 15 women and 7 men, with a mean age of 50.5 years (range, 22-76). Preoperative mean total calcium was 11.74 mg/dL (range, 10-15), ionized calcium was 6.19 mg/dL (range, 5.2-7.7), and intact parathyroid hormone was 153.5 pg/mL (range, 83.1-551). Postoperative mean ionized calcium was 4.56 mg/dL (range, 4.1-5.57). Twenty sestamibi scans had a positive localization, and 2 scans had no localization. At surgery, 18 solitary adenomas, 3 diffuse hyperplasias, and 1 patient with four normal parathyroid glands were found. Sixteen sestamibi scans were true positive (solitary adenoma), 4 scans were false positive (2 diffuse hyperplasia, 1 wrong side, and 1 lymph node), 1 negative scan was true negative (diffuse hyperplasia), and 1 negative scan was false negative (adenoma). One patient (four normal glands) at the second operation had a supernumerary fifth gland adenoma excised from the mediastinum. Preoperative Tc-99m-sestamibi scan did not offer any advantage when a complete bilateral neck exploration is performed. Sixteen of (84%) adenomas were correctly localized, but 18 of 19 adenomas were in the neck and were easily found. The 1 ectopic adenoma was not found by scanning or with initial surgery. The 4 of 22 (18%) false-positive localizations and the 2 of 22 (9%) negative scans contributed nothing to the surgery. Of the 22 localizing sestamibi scans, surgery was not altered to affect the outcome. At a cost of $550 per sestamibi scan and with the error inherent in the scan, it is not cost effective to obtain Tc-99m-sestamibi scan before initial surgery for primary hyperparathyroidism.


Assuntos
Hiperparatireoidismo/economia , Cuidados Pré-Operatórios/economia , Compostos Radiofarmacêuticos/economia , Tecnécio Tc 99m Sestamibi/economia , Adulto , Idoso , Cálcio/sangue , Análise Custo-Benefício , Reações Falso-Positivas , Feminino , Humanos , Hiperparatireoidismo/sangue , Hiperparatireoidismo/diagnóstico por imagem , Hiperparatireoidismo/cirurgia , Masculino , Pessoa de Meia-Idade , Hormônio Paratireóideo/sangue , Valor Preditivo dos Testes , Estudos Prospectivos , Cintilografia
18.
Laryngoscope ; 107(6): 753-8, 1997 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9185731

RESUMO

This study retrospectively reviews 60 cases of primary hyperparathyroidism, 21 of whom underwent technetium 99 sestamibi scanning and 10 of whom underwent thallium 201/technetium 99 pertechnetate scanning preoperatively. The sestamibi and thallium scans demonstrated an 89.5% and a 62.5% sensitivity rate for adenoma, respectively. Neither scan demonstrated hyperplastic glands well. Although the scans localized adenomatous glands to the correct side well, the ability to localize them more discretely was 68.4% and 62.5%, respectively. In cases of solitary adenoma the effect of an accurate preoperative scan on operative time for bilateral exploration was not significant, whereas the experience of the attending surgeon was significant. Also, the cost of the scans at our institution was greater than the cost of the time saved in performing even unilateral neck exploration. Thus preoperative radionuclide scanning is not cost-effective for the initial exploration of patients with primary hyperparathyroidism and is insufficiently sensitive to make routine unilateral neck exploration for adenoma consistently effective.


Assuntos
Adenoma/diagnóstico por imagem , Hiperparatireoidismo/diagnóstico por imagem , Neoplasias das Paratireoides/diagnóstico por imagem , Compostos Radiofarmacêuticos , Pertecnetato Tc 99m de Sódio , Tecnécio Tc 99m Sestamibi , Radioisótopos de Tálio , Adenoma/complicações , Adenoma/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise Custo-Benefício , Feminino , Humanos , Hiperparatireoidismo/etiologia , Hiperparatireoidismo/cirurgia , Masculino , Pessoa de Meia-Idade , Neoplasias das Paratireoides/complicações , Neoplasias das Paratireoides/cirurgia , Cintilografia , Compostos Radiofarmacêuticos/economia , Estudos Retrospectivos , Sensibilidade e Especificidade , Pertecnetato Tc 99m de Sódio/economia , Tecnécio Tc 99m Sestamibi/economia , Radioisótopos de Tálio/economia
19.
Ann Vasc Surg ; 10(4): 325-9, 1996 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8879386

RESUMO

Dipyridamole-sestamibi (PMIBI) is recommended prior to vascular surgery in patients with > or = 1 Eagle criteria (Q waves, history of ventricular ectopy, diabetes, advanced age, and/or angina). To review our cardiac morbidity and mortality and the need for preoperative PMIBI, we reviewed 109 consecutive patients with a mean age of 59 years who underwent 145 elective major vascular procedures over a 1-year period. Seventy patients (with a mean of 0.8 Eagle criteria) underwent 92 vascular procedures without preoperative PMIBI and without coronary revascularization. Thirty-one patients (with a mean of 1.1 Eagle criteria) underwent 39 procedures without coronary revascularization following PMIBI, which showed reversible ischemia in seven and a fixed defect in 10; findings were normal in 14. Preoperative coronary bypass or angioplasty was limited to eight patients (14 procedures, mean of 1.6 Eagle criteria) who had unstable angina with (2 patients) or without (6 patients) acute myocardial infarction. There were four perioperative myocardial infarctions (2.8%), seven cardiac events overall (4.8%), and one cardiac death (0.7%). Three (43%) of the seven cardiac events occurred in patients with a normal scan or fixed defect on PMIBI imaging. In the absence of unstable angina, PMIBI had a sensitivity of only 25% and a specificity of 80% for cardiac events. We conclude that among patients without severe cardiac symptoms (1) PMIBI has a very limited ability to identify patients at risk for cardiac complications, and (2) preoperative PMIBI is neither necessary nor cost-effective.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Dipiridamol , Cuidados Pré-Operatórios , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Procedimentos Cirúrgicos Vasculares , Vasodilatadores , Fatores Etários , Idoso , Angina Pectoris/complicações , Angina Instável/complicações , Angioplastia Coronária com Balão , Ponte de Artéria Coronária , Doença das Coronárias/complicações , Análise Custo-Benefício , Morte Súbita Cardíaca/etiologia , Complicações do Diabetes , Dipiridamol/economia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Isquemia Miocárdica/etiologia , Cuidados Pré-Operatórios/economia , Cintilografia , Compostos Radiofarmacêuticos/economia , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi/economia , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Vasodilatadores/economia , Complexos Ventriculares Prematuros/complicações
20.
J Am Coll Cardiol ; 26(3): 639-47, 1995 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-7642853

RESUMO

OBJECTIVES: This study assessed the incremental prognostic implications of normal and equivocal exercise technetium-99m (Tc-99m) sestamibi single-photon emission computed tomography (SPECT) and sought to determine its incremental prognostic value, impact on patient management and cost implications. BACKGROUND: The prognostic implications of Tc-99m sestamibi SPECT are not well defined, and risk stratification using this test has not been explored. METHODS: We studied 1,702 patients referred for exercise Tc-99m sestamibi SPECT who were followed up for a mean (+/- SD) of 20 +/- 5 months. Patients with previous percutaneous transluminal coronary angioplasty or coronary artery bypass surgery were excluded. The SPECT studies were assessed using semiquantitative visual analysis. Cardiac death and myocardial infarction were considered "hard" events, and coronary angioplasty and bypass surgery > 60 days after testing were considered "soft" events. RESULTS: Of the 1,702 patients studied, 1,131 had normal or equivocal scan results. A total of 10 events occurred in this group (1 cardiac death and 1 myocardial infarction [0.2% hard events]; 4 coronary angioplasty and 4 bypass surgery procedures [0.7% soft events]). The rates of hard events and referral to catheterization after SPECT were similarly low in patients with a low (< 0.15), intermediate (0.15 to 0.85) and high (> 0.85) post-exercise treadmill test (ETT) likelihood of coronary artery disease. With respect to scan type, patients with normal, probably normal or equivocal scan results had similarly low hard event rates. In the 571 patients with abnormal scan results, there were 43 hard events (7.5%) and 42 soft events (7.4%) (p < 0.001 vs. 1,131 patients with normal scan results for both). When the complete spectrum of scan responses was considered, SPECT provided incremental prognostic value in all patient subgroups analyzed. However, the nuclear scan was cost-effective only in patients with interpretable exercise ECG responses and an intermediate to high post-ETT likelihood of coronary artery disease and in those with uninterpretable exercise ECG responses and an intermediate to high pre-ETT likelihood of coronary artery disease. CONCLUSIONS: Normal or equivocal exercise Tc-99m sestamibi study results are associated with a benign prognosis, even in patients with a high likelihood of coronary artery disease. Although incremental prognostic value is added by nuclear testing in all patient subgroups, a testing strategy incorporating nuclear testing proved to be cost-effective only in the groups with an intermediate to high likelihood of coronary artery disease before scanning.


Assuntos
Teste de Esforço/métodos , Isquemia Miocárdica/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Custos e Análise de Custo , Teste de Esforço/economia , Teste de Esforço/estatística & dados numéricos , Feminino , Seguimentos , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/economia , Isquemia Miocárdica/epidemiologia , Prognóstico , Fatores de Risco , Tecnécio Tc 99m Sestamibi/economia , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único/economia , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA