1.
Circ Cardiovasc Imaging ; 17(6): e016635, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38889213

RESUMO

BACKGROUND: Despite recent guideline recommendations, quantitative perfusion (QP) estimates of myocardial blood flow from cardiac magnetic resonance (CMR) have only been sparsely validated. Furthermore, the additional diagnostic value of utilizing QP in addition to the traditional visual expert interpretation of stress-perfusion CMR remains unknown. The aim was to investigate the correlation between myocardial blood flow measurements estimated by CMR, positron emission tomography, and invasive coronary thermodilution. The second aim is to investigate the diagnostic performance of CMR-QP to identify obstructive coronary artery disease (CAD). METHODS: Prospectively enrolled symptomatic patients with >50% diameter stenosis on computed tomography angiography underwent dual-bolus CMR and positron emission tomography with rest and adenosine-stress myocardial blood flow measurements. Subsequently, an invasive coronary angiography (ICA) with fractional flow reserve and thermodilution-based coronary flow reserve was performed. Obstructive CAD was defined as both anatomically severe (>70% diameter stenosis on quantitative coronary angiography) or hemodynamically obstructive (ICA with fractional flow reserve ≤0.80). RESULTS: About 359 patients completed all investigations. Myocardial blood flow and reserve measurements correlated weakly between estimates from CMR-QP, positron emission tomography, and ICA-coronary flow reserve (r<0.40 for all comparisons). In the diagnosis of anatomically severe CAD, the interpretation of CMR-QP by an expert reader improved the sensitivity in comparison to visual analysis alone (82% versus 88% [P=0.03]) without compromising specificity (77% versus 74% [P=0.28]). In the diagnosis of hemodynamically obstructive CAD, the accuracy was only moderate for a visual expert read and remained unchanged when additional CMR-QP measurements were interpreted. CONCLUSIONS: CMR-QP correlates weakly to myocardial blood flow measurements by other modalities but improves diagnosis of anatomically severe CAD. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03481712.


Assuntos
Angiografia Coronária , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Termodiluição , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Velocidade do Fluxo Sanguíneo , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Circulação Coronária/fisiologia , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Imagem de Perfusão do Miocárdio/métodos , Tomografia por Emissão de Pósitrons/métodos , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
2.
Burns ; 50(6): 1519-1527, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38570251

RESUMO

INTRODUCTION: Mid-regional proadrenomedullin (MR-proADM) reflects the adrenomedullin level, which has vasodilatory activity, decreases endothelial permeability, and downregulates proinflammatory cytokines. Sepsis diagnosis in these patients is difficult, and MR-proADM is a widely studied sepsis biomarker. This study evaluates MR-proADM levels during the resuscitation phase, considering the potential influence of haemodynamic changes and its usefulness for the early sepsis detection in burn patients. METHODS: A prospective observational study performed in the Critical Burn Unit. Demographic data, burn characteristics, comorbidities, prognostic/severity scales, and haemodynamic parameters were collected. The resuscitation protocol guided by diuresis, transpulmonary thermodilution, and lactate levels was followed. Blood samples were collected at various time points for biomarker measurement. Biomarker levels, including MR-proADM, C-reactive protein, and procalcitonin were measured during the resuscitation phase and septic episodes. RESULTS: Twenty-seven patients were included, with a mean age of 51 years, a mean total body surface area burn of 41.8%, a mean Abbreviated Burn Severity Index of 9.7, and a mean Baux score of 92. MR-proADM levels were elevated on admission (0.9 ± 0.5 nmol/l) and continued to increase slightly during the resuscitation phase (2.4 ± 2.2 nmol/l). Haemodynamic changes during resuscitation did not significantly affect MR-proADM levels. Twelve of the 27 patients developed sepsis, whose MR-proADM levels were significantly elevated on the day of clinical diagnosis (3.91 ± 2.99 nmol/l) and even the day before (2.57 ± 3.37). Higher MR-proADM levels were associated with greater severity as measured by the Sequential Organ Failure Assessment score. The mean MR-proadrenomedullin values during resuscitation in the patients who died was 3.51 ± 2.30 nmol/l, whereas in the survivors it was 1.28 ± 1.10 nmol/l (p = 0.0001). CONCLUSION: MR-proadrenomedullin values are elevated after thermal injury but are not affected by haemodynamic changes. During septic episodes in burn patients, MR-proADM rises early (the day before sepsis diagnosis). Higher levels of MR-proADM are associated with greater organ dysfunction and mortality.


Assuntos
Adrenomedulina , Biomarcadores , Queimaduras , Proteína C-Reativa , Pró-Calcitonina , Precursores de Proteínas , Ressuscitação , Sepse , Humanos , Queimaduras/sangue , Queimaduras/complicações , Adrenomedulina/sangue , Pessoa de Meia-Idade , Masculino , Sepse/sangue , Sepse/diagnóstico , Feminino , Biomarcadores/sangue , Estudos Prospectivos , Precursores de Proteínas/sangue , Ressuscitação/métodos , Pró-Calcitonina/sangue , Adulto , Proteína C-Reativa/metabolismo , Idoso , Hemodinâmica/fisiologia , Ácido Láctico/sangue , Diagnóstico Precoce , Termodiluição/métodos , Fragmentos de Peptídeos
3.
Circ Cardiovasc Interv ; 17(7): e013860, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38682331

RESUMO

BACKGROUND: Reliable assessment of coronary microvascular function is essential. Techniques to measure absolute coronary blood flow are promising but need validation. The objectives of this study were: first, to validate the potential of saline infusion to generate maximum hyperemia in vivo. Second, to validate absolute coronary blood flow measured with continuous coronary thermodilution at high (40-50 mL/min) infusion speeds and asses its safety. METHODS: Fourteen closed-chest sheep underwent absolute coronary blood flow measurements with increasing saline infusion speeds at different dosages under general anesthesia. An additional 7 open-chest sheep underwent these measurements with epicardial Doppler flow probes. Coronary flows were compared with reactive hyperemia after 45 s of coronary occlusion. RESULTS: Twenty milliliters per minute of saline infusion induced a significantly lower hyperemic coronary flow (140 versus 191 mL/min; P=0.0165), lower coronary flow reserve (1.82 versus 3.21; P≤0.0001), and higher coronary resistance (655 versus 422 woods units; P=0.0053) than coronary occlusion. On the other hand, 30 mL/min of saline infusion resulted in hyperemic coronary flow (196 versus 192 mL/min; P=0.8292), coronary flow reserve (2.77 versus 3.21; P=0.1107), and coronary resistance (415 versus 422 woods units; P=0.9181) that were not different from coronary occlusion. Hyperemic coronary flow was 40.7% with 5 mL/min, 40.8% with 10 mL/min, 73.1% with 20 mL/min, 102.3% with 30 mL/min, 99.0% with 40 mL/min, and 98.0% with 50 mL/min of saline infusion when compared with postocclusive hyperemic flow. There was a significant bias toward flow overestimation (Bland-Altman: bias±SD, -73.09±30.52; 95% limits of agreement, -132.9 to -13.27) with 40 to 50 mL/min of saline. Occasionally, ischemic changes resulted in ventricular fibrillation (9.5% with 50 mL/min) at higher infusion rates. CONCLUSIONS: Continuous saline infusion of 30 mL/min but not 20 mL/min induced maximal hyperemia. Absolute coronary blood flow measured with saline infusion speeds of 40 to 50 mL/min was not accurate and not safe.


Assuntos
Circulação Coronária , Hiperemia , Microcirculação , Termodiluição , Animais , Hiperemia/fisiopatologia , Velocidade do Fluxo Sanguíneo , Vasos Coronários/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Infusões Intravenosas , Ovinos , Solução Salina/administração & dosagem , Reprodutibilidade dos Testes
4.
J Cardiothorac Vasc Anesth ; 38(7): 1484-1491, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38631929

RESUMO

OBJECTIVE: To investigate the accuracy, precision, and trending ability of noninvasive bioreactance-based Starling SV and the mini invasive pulse-power device LiDCOrapid as compared to thermodilution cardiac output (TDCO) as measured by pulmonary artery catheter when assessing cardiac index (CIx) in the setting of elective open abdominal aortic (AA) surgery. DESIGN: A prospective method-comparison study. SETTING: Oulu University Hospital, Finland. PARTICIPANTS: Forty patients undergoing elective open abdominal aortic surgery. INTERVENTIONS: Intraoperative CI measurements were obtained simultaneously with TDCO and the study monitors, resulting in 627 measurement pairs with Starling SV and 497 with LiDCOrapid. MEASUREMENTS AND MAIN RESULTS: The Bland-Altman method was used to investigate the agreement among the devices, and four-quadrant plots with error grids were used to assess trending ability. The agreement between TDCO and Starling SV was associated with a bias of 0.18 L/min/m2 (95% confidence interval [CI] = 0.13 to 0.23), wide limits of agreement (LOA = -1.12 to 1.47 L/min/m2), and a percentage error (PE) of 63.7 (95% CI = 52.4-71.0). The agreement between TDCO and LiDCOrapid was associated with a bias of -0.15 L/min/m2 (95% CI = -0.21 to -0.09), wide LOA (-1.56 to 1.37), and a PE of 68.7 (95% CI = 54.9-79.6). The trending ability of neither device was sufficient. CONCLUSION: The CI measurements achieved with Starling SV and LiDCOrapid were not interchangeable with TDCO, and the ability to track changes in CI was poor. These results do not support the use of either study device in monitoring CI during open AA surgery.


Assuntos
Aorta Abdominal , Débito Cardíaco , Monitorização Intraoperatória , Termodiluição , Humanos , Masculino , Feminino , Estudos Prospectivos , Débito Cardíaco/fisiologia , Idoso , Aorta Abdominal/cirurgia , Reprodutibilidade dos Testes , Monitorização Intraoperatória/métodos , Monitorização Intraoperatória/normas , Pessoa de Meia-Idade , Termodiluição/métodos , Procedimentos Cirúrgicos Vasculares/métodos
5.
J Clin Monit Comput ; 38(1): 139-146, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37458916

RESUMO

PURPOSE: Pulse Decomposition Analysis (PDA) uses integration of the systolic area of a distally transmitted aortic pulse as well as arterial stiffness estimates to compute cardiac output. We sought to assess agreement of cardiac output (CO) estimation between continuous pulmonary artery catheter (PAC) guided thermodilution (CO-CCO) and a wireless, wearable noninvasive device, (Vitalstream, Caretaker Medical, Charlottesville, VA), that utilizes the Pulse Decomposition Analysis (CO-PDA) method in postoperative cardiac surgery patients in the intensive care unit. METHODS: CO-CCO measurements were compared with post processed CO-PDA measurements in prospectively enrolled adult cardiac surgical intensive care unit patients. Uncalibrated CO-PDA values were compared for accuracy with CO-CCO via a Bland-Altman analysis considering repeated measurements and a concordance analysis with a 10% exclusion zone. RESULTS: 259.7 h of monitoring data from 41 patients matching 15,583 data points were analyzed. Mean CO-CCO was 5.55 L/min, while mean values for the CO-PDA were 5.73 L/min (mean of differences +- SD 0.79 ± 1.11 L/min; limits of agreement - 1.43 to 3.01 L/min), with a percentage error of 37.5%. CO-CCO correlation with CO-PDA was moderate (0.54) and concordance was 0.83. CONCLUSION: Compared with the CO-CCO Swan-Ganz, cardiac output measurements obtained using the CO-PDA were not interchangeable when using a 30% threshold. These preliminary results were within the 45% limits for minimally invasive devices, and pending further robust trials, the CO-PDA offers a noninvasive, wireless solution to complement and extend hemodynamic monitoring within and outside the ICU.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Artéria Pulmonar , Adulto , Humanos , Termodiluição/métodos , Débito Cardíaco , Cateterismo de Swan-Ganz , Procedimentos Cirúrgicos Cardíacos/métodos , Cuidados Críticos , Unidades de Terapia Intensiva , Reprodutibilidade dos Testes
6.
J Anesth ; 38(1): 1-9, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37740733

RESUMO

PURPOSE: Several technical aspects of the Fick method limit its use intraoperatively. A data-driven modification of the Fick method may enable its use in intraoperative settings. METHODS: This two-center retrospective observational study included 57 (28 and 29 in each center) patients who underwent off-pump coronary artery bypass graft (OPCAB) surgery. Intraoperative recordings of physiological data were obtained and divided into training and test datasets. The Fick equation was used to calculate cardiac output (CO-Fick) using ventilator-determined variables, intraoperative hemoglobin level, and SvO2, with continuous thermodilution cardiac output (CCO) used as a reference. A modification CO-Fick was derived and validated: CO-Fick-AD, which adjusts the denominator of the original equation. RESULTS: Increased deviation between CO-Fick and CCO was observed when oxygen extraction was low. The root mean square error of CO-Fick was decreased from 6.07 L/min to 0.70 L/min after the modification. CO-Fick-AD showed a mean bias of 0.17 (95% CI 0.00-0.34) L/min, with a 36.4% (95% CI 30.6-44.4%) error. The concordance rates of CO-Fick-AD ranged from 73.3 to 87.1% depending on the time interval and exclusion zone. CONCLUSIONS: The original Fick method is not reliable when oxygen extraction is low, but a modification using data-driven approach could enable continuous estimation of cardiac output during the dynamic intraoperative period with minimal bias. However, further improvements in precision and trending ability are needed.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Humanos , Débito Cardíaco/fisiologia , Monitorização Fisiológica , Consumo de Oxigênio , Oxigênio , Termodiluição/métodos
7.
Intern Emerg Med ; 19(2): 501-509, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37700181

RESUMO

Pulmonary edema and its association with low flow times has been observed in postcardiac arrest patients. However, diagnosis of distinct types of lung pathology is difficult.The aim of this study was to investigate pulmonary edema by transpulmonary thermodilution (TPTD) after out-of-hospital cardiac arrest (OHCA), and the correlation to downtimes. In this retrospective single-center study consecutive patients with return of spontaneous circulation (ROSC) following OHCA, age ≥ 18, and applied TPTD were enrolled. According to downtimes, patients were divided into a short and a long no-flow-time group, and data of TPTD were analysed. We identified 45 patients (n = 25 short no-flow time; n = 20 long no-flow time) who met the inclusion criteria. 24 h after ROSC, the extra vascular lung water index (EVLWI) was found to be lower in the group with short no-flow time compared to the group with long no-flow time (10.7 ± 3.5 ml/kg vs. 12.8 ± 3.9 ml/kg; p = 0.08) and remained at a similar level 48 h (10.9 ± 4.3 ml/kg vs. 12.9 ± 4.9 ml/kg; p = 0.25) and 72 h (11.1 ± 5.0 ml/kg vs. 13.9 ± 7.7 ml/kg; p = 0.27) post-ROSC. We found a statistically significant and moderate correlation between no-flow duration and EVLWI 48 h (r = 0.51; p = 0.002) and 72 h (r = 0.54; p = 0.004) post-ROSC. Pulmonary vascular permeability index (PVPI) was not correlated with downtimes. Our observation underlines the presence of cardiac arrest-related lung edema by determination of EVLWI. The duration of no-flow times is a relevant factor for increased extravascular lung water index.


Assuntos
Parada Cardíaca , Edema Pulmonar , Humanos , Edema Pulmonar/diagnóstico , Edema Pulmonar/etiologia , Termodiluição , Estudos Retrospectivos , Pulmão , Água Extravascular Pulmonar , Parada Cardíaca/complicações , Edema
9.
J Clin Monit Comput ; 37(4): 1095-1102, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37166694

RESUMO

Thermodilution is the gold standard for cardiac output measurement in critically ill patients. Its application in extracorporeal therapy is limited, as a portion of the thermal indicator is drawn into the extracorporeal circuit. The behaviour of thermodilution signals in extracorporeal circuits is unknown. We investigated thermodilution curves within a closed-circuit and assessed the impact of injection volume, flow and distance on the behaviour of the thermodilution signals and catheter constants. We injected 3, 5, 7 and 10 ml of thermal indicator into a heated closed circuit. Thermistors at distances of 40, 60, 80, and 100 cm from the injection port recorded the thermodilution signals (at flow settings of 0.5, 1, 1.5, and 2 L/min). Area under the curve (AUC), rise time, exponential decay and catheter constants were analysed. Linear mixed-effects models were used to evaluate the impact of circuit flow, distance and injection volume. Catheter positioning did not influence AUC (78 injections). Catheter constants were independent of flow, injection volume or distance to the injection port. The distance to the injection port increased peak temperature and rise time and decreased exponential time constant significantly. The distance to the injection port did not influence catheter constants, but the properties of the thermodilution signal itself. This may influence measurements that depend on the exponential decay of the thermodilution signal such as right ventricular ejection fraction.


Assuntos
Termodiluição , Função Ventricular Direita , Humanos , Volume Sistólico , Catéteres , Débito Cardíaco
10.
BMC Anesthesiol ; 23(1): 180, 2023 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-37231335

RESUMO

BACKGROUND: The new noninvasive Vitalstream (VS) continuous physiological monitor (Caretaker Medical LLC, Charlottesville, Virginia), allows continuous cardiac output by a low pump-inflated, finger cuff that pneumatically couples arterial pulsations via a pressure line to a pressure sensor for detection and analysis. Physiological data are communicated wirelessly to a tablet-based user interface via Bluetooth or Wi-Fi. We evaluated its performance against thermodilution cardiac output in patients undergoing cardiac surgery. METHODS: We compared the agreement between thermodilution cardiac output to that obtained by the continuous noninvasive system during cardiac surgery pre and post-cardiac bypass. Thermodilution cardiac output was performed routinely when clinically indicated by an iced saline cold injectate system. All comparisons between VS and TD/CCO data were post-processed. In order to match the VS CO readings to the averaged discrete TD bolus data, the averaged CO readings of the ten seconds of VS CO data points prior to a sequence of TD bolus injections was matched. Time alignment was based on the medical record time and the VS time-stamped data points. The accuracy against reference TD measurements was assessed via Bland-Altman analysis of the CO values and standard concordance analysis of the ΔCO values (with a 15% exclusion zone). RESULTS: Analysis of the data compared the accuracy of the matched measurement pairs of VS and TD/CCO VS absolute CO values with and without initial calibration to the discrete TD CO values, as well as the trending ability, i.e., ΔCO values of the VS physiological monitor compared to those of the reference. The results were comparable with other non-invasive as well as invasive technologies and Bland-Altman analyses showed high agreement between devices in a diverse patient population. The results are significant regarding the goal of expanding access to effective, wireless and readily implemented fluid management monitoring tools to hospital sections previously not covered because of the limitations of traditional technologies. CONCLUSION: This study demonstrated that the agreement between the VS CO and TD CO was clinically acceptable with a percent error (PE) of 34.5 to 38% with and without external calibration. The threshold for an acceptable agreement between the VS and TD was considered to be below 40% which is below the threshold recommended by others.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Humanos , Débito Cardíaco/fisiologia , Ponte de Artéria Coronária , Dedos , Artérias , Termodiluição/métodos , Reprodutibilidade dos Testes
11.
J Cardiothorac Vasc Anesth ; 37(7): 1143-1151, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37076386

RESUMO

OBJECTIVES: The clinical use of less-invasive devices that calculate the cardiac output from arterial pressure waveform is increasing. The authors aimed to evaluate the accuracy and characteristics of the systemic vascular resistance index (SVRI) of the cardiac index measured by 2 less-invasive devices, fourth-generation FloTrac (CIFT) and LiDCOrapid (CILR), compared with the intermittent thermodilution technique, using a pulmonary artery catheter (CITD). DESIGN: This was a prospective observational study. SETTING: This study was conducted at a single university hospital. PARTICIPANTS: Twenty-nine adult patients undergoing elective cardiac surgery. INTERVENTIONS: Elective cardiac surgery was used as an intervention. MEASUREMENTS AND MAIN RESULTS: Hemodynamic parameters, CIFT, CILR, and CITD, were measured after the induction of general anesthesia, at the start of cardiopulmonary bypass, after completion of weaning from cardiopulmonary bypass, 30 minutes after weaning, and at sternal closure (135 measurements in total). The CIFT and CILR had moderate correlations with CITD (r = 0.62 and 0.58, respectively). Compared with CITD, CIFT, and CILR had a bias of -0.73 and -0.61 L/min/m2, limit of agreement of -2.14-to-0.68 L/min/m2 and -2.42-to-1.20 L/min/m2, and percentage error of 39.9% and 51.2%, respectively. Subgroup analysis for evaluating SVRI characteristics showed that the percentage errors of CIFT and CILR were 33.9% and 54.5% in low SVRI (<1,200 dyne×s/cm5/m), 37.6% and 47.9% in moderate SVRI (1,200-1,800 dyne×s/cm5/m), 49.3% and 50.6% in high SVRI (>1,800 dyne·s/cm5/m2), respectively. CONCLUSIONS: The accuracy of CIFT or CILR was not clinically acceptable for cardiac surgery. Fourth-generation FloTrac was unreliable in high SVRI. LiDCOrapid was inaccurate across a broad range of SVRI, and minimally affected by SVRI.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Monitorização Intraoperatória , Adulto , Humanos , Monitorização Intraoperatória/métodos , Débito Cardíaco , Resistência Vascular , Hemodinâmica , Procedimentos Cirúrgicos Cardíacos/métodos , Termodiluição/métodos , Reprodutibilidade dos Testes
12.
J Cardiothorac Vasc Anesth ; 37(8): 1377-1381, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37121841

RESUMO

OBJECTIVES: The decision algorithm for managing patients in cardiogenic shock depends on cardiac index (CI) estimates. Cardiac index estimation via thermodilution (CI-TD) using a pulmonary artery catheter is used commonly for obtaining CI in these patients. Minimally invasive methods of estimating CI, such as multibeat analysis (CI-MBA), may be an alternative in this population. DESIGN: A prospective, observational study. SETTING: Cardiac intensive care unit. PARTICIPANTS: Twenty-two subjects in cardiogenic shock provided 101 paired CI measurements. INTERVENTIONS: Measurements were obtained concomitantly by intermittent CI-TD and CI-MBA (Argos Cardiac Output Monitor; Retia Medical, Valhalla, NY). For each CI-TD, CI-MBA estimates were averaged over 1 minute to provide paired values. Bland-Altman and 4-quadrant analyses were performed by plotting changes between successive CI measurements (ΔCI) from each of the 2 methods. Concordance was calculated as a percentage using ΔCI data points from the 2 methods, outside an exclusion zone of 15%. MEASUREMENTS AND MAIN RESULTS: The correlation coefficient between CI-MBA and CI-TD was 0.78 across patients. Mean CI-TD was 2.19 ± 0.46 L/min/m2 and mean CI-MBA was 2.38 ± 0.59 L/min/m2. The mean difference between CI-MBA and CI-TD (bias ± SD) was 0.20 ± 0.47 L/min/m2, and the limits of agreement were -0.72 to 1.11 L/min/m2. The percentage error was 40.0%. The concordance rate was 94%. A secondary analysis of a subgroup of patients during periods of arrhythmia demonstrated a similar accuracy of performance of CI-MBA. CONCLUSIONS: Cardiac index-MBA is not interchangeable with CI-TD. However, CI-MBA provides reasonable correlation and clinically acceptable trending ability compared with CI-TD. Cardiac output-MBA may be useful in trending changes in CI in patients with cardiogenic shock, especially in those whose pulmonary artery catheterization placement carries a high risk or is unobtainable.


Assuntos
Cateterismo de Swan-Ganz , Choque Cardiogênico , Humanos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/terapia , Reprodutibilidade dos Testes , Débito Cardíaco , Ponte de Artéria Coronária , Termodiluição/métodos
13.
JACC Cardiovasc Imaging ; 16(10): 1321-1331, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37052562

RESUMO

BACKGROUND: Fractional flow reserve (FFR) derived from invasive coronary angiography (QFR) is promising for evaluation of intermediate coronary artery stenosis. OBJECTIVES: The authors aimed to compare the diagnostic performance of QFR and the guideline-recommended invasive FFR using 82Rubidium positron emission tomography (82Rb-PET) myocardial perfusion imaging as reference standard. METHODS: This is a prospective, observational study of symptomatic patients with suspected obstructive coronary artery disease on coronary computed tomography angiography (≥50% diameter stenosis in ≥1 vessel). All patients were referred to 82Rb-PET and invasive coronary angiography with FFR and QFR assessment of all intermediate (30%-90% diameter stenosis) stenoses. Main analyses included a comparison of the ability of QFR and FFR to identify reduced myocardial blood flow (<2 mL/g/min) during vasodilation and/or relative perfusion abnormalities (summed stress score ≥4 in ≥2 adjacent segments). RESULTS: A total of 250 patients (320 vessels) with indication for invasive physiological assessment were included. The continuous relationship of 82Rb-PET stress myocardial blood flow per 0.10 increase in FFR was +0.14 mL/g/min (95% CI: 0.07-0.21 mL/g/min) and +0.08 mL/g/min (95% CI: 0.02-0.14 mL/g/min) per 0.10 QFR increase. Using 82Rb-PET as reference, QFR and FFR had similar diagnostic performance on both a per-patient level (accuracy: 73%; 95% CI: 67%-79%; vs accuracy: 71%; 95% CI: 64%-78%) and per-vessel level (accuracy: 70%; 95% CI: 64%-75%; vs accuracy: 68%; 95% CI: 62%-73%). The per-vessel feasibility was 84% (95% CI: 80%-88%) for QFR and 88% (95% CI: 85%-92%) for FFR by intention-to-diagnose analysis. CONCLUSIONS: With 82Rb-PET as reference modality, the wire-free QFR solution showed similar diagnostic accuracy as invasive FFR in evaluation of intermediate coronary stenosis. (DAN-NICAD - Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease; NCT02264717).


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Constrição Patológica , Termodiluição , Vasos Coronários/diagnóstico por imagem , Valor Preditivo dos Testes , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Angiografia Coronária/métodos , Tomografia por Emissão de Pósitrons , Índice de Gravidade de Doença
14.
J Anesth ; 37(3): 394-400, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36905408

RESUMO

PURPOSE: The estimated continuous cardiac output (esCCO) system was recently developed as a noninvasive hemodynamic monitoring alternative to the thermodilution cardiac output (TDCO). However, the accuracy of continuous cardiac output measurements by the esCCO system compared to TDCO under different respiratory conditions remains unclear. This prospective study aimed to assess the clinical accuracy of the esCCO system by continuously measuring the esCCO and TDCO. METHODS: Forty patients who had undergone cardiac surgery with a pulmonary artery catheter were enrolled. We compared the esCCO with TDCO from mechanical ventilation to spontaneous respiration through extubation. Patients undergoing cardiac pacing during esCCO measurement, those receiving treatment with an intra-aortic balloon pump, and those with measurement errors or missing data were excluded. In total, 23 patients were included. Agreement between the esCCO and TDCO measurements was evaluated using Bland-Altman analysis with a 20 min moving average of the esCCO. RESULTS: The paired esCCO and TDCO measurements (939 points before extubation and 1112 points after extubation) were compared. The respective bias and standard deviation (SD) values were 0.13 L/min and 0.60 L/min before extubation, and - 0.48 L/min and 0.78 L/min after extubation. There was a significant difference in bias before and after extubation (P < 0.001); the SD before and after extubation was not significant (P = 0.315). The percentage errors were 25.1% before extubation and 29.6% after extubation, which is the criterion for acceptance of a new technique. CONCLUSION: The accuracy of the esCCO system is clinically acceptable to that of TDCO under mechanical ventilation and spontaneous respiration.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Humanos , Estudos Prospectivos , Monitorização Fisiológica/métodos , Débito Cardíaco , Termodiluição/métodos
15.
Heart Vessels ; 38(3): 341-347, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36181530

RESUMO

The pulmonary artery catheter (PAC)-despite its invasiveness-remains the gold standard for cardiac output (CO) monitoring. The FloTrac system, a less invasive hemodynamic monitor has been developed, which estimates CO using arterial pressure waveform analysis without external calibration. Recently, an upgraded version of FloTrac system with improved algorithm to follow changes in vascular resistance was introduced into the market. The aim of this study was to assess the reliability of the CO estimated from the fourth-generation FloTrac/EV1000 system (COFT) compared to that measured with PAC using the thermodilution method (COPAC) during robotic-assisted off-pump coronary artery bypass (OPCAB) surgery. COFT and COPAC were obtained simultaneously at 4 predefined time points during robotic-assisted OPCAB: 5 min after the induction of general anesthesia (T1), after starting one-lung ventilation (T2), after capnothorax (T3), and after mini-thoracotomy was performed (T4). The agreement of data was investigated by Bland-Altman analysis. Thirty-four patients were initially enrolled. After exclusion, 32 patients and a total of 128 paired CO measurements were obtained. The overall bias was 1.46 L/min, the 95% limits of agreements were - 3.40 to 6.33 L/min, and the percentage error was 72.98%. Regression analysis of the systemic vascular resistance index (SVRI) and the bias between COPAC and COFT showed that the bias was moderately correlated with the SVRI (r2 = 0.43; p < 0.0001). Despite a software upgrade, the reliability of the fourth-generation FloTrac/EV1000™ system during robotic-assisted OPCAB to estimate CO was not acceptable, especially in patients with low SVRI.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Procedimentos Cirúrgicos Robóticos , Humanos , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Reprodutibilidade dos Testes , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Artéria Pulmonar/cirurgia , Monitorização Intraoperatória/métodos , Débito Cardíaco , Termodiluição/métodos
16.
J Clin Monit Comput ; 37(2): 559-565, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36269451

RESUMO

We sought to assess agreement of cardiac output estimation between continuous pulmonary artery catheter (PAC) guided thermodilution (CO-CTD) and a novel pulse wave analysis (PWA) method that performs an analysis of multiple beats of the arterial blood pressure waveform (CO-MBA) in post-operative cardiac surgery patients. PAC obtained CO-CTD measurements were compared with CO-MBA measurements from the Argos monitor (Retia Medical; Valhalla, NY, USA), in prospectively enrolled adult cardiac surgical intensive care unit patients. Agreement was assessed via Bland-Altman analysis. Subgroup analysis was performed on data segments identified as arrhythmia, or with low CO (less than 5 L/min). 927 hours of monitoring data from 79 patients was analyzed, of which 26 had arrhythmia. Mean CO-CTD was 5.29 ± 1.14 L/min (bias ± precision), whereas mean CO-MBA was 5.36 ± 1.33 L/min, (4.95 ± 0.80 L/min and 5.04 ± 1.07 L/min in the arrhythmia subgroup). Mean of differences was 0.04 ± 1.04 L/min with an error of 38.2%. In the arrhythmia subgroup, mean of differences was 0.14 ± 0.90 L/min with an error of 35.4%. In the low CO subgroup, mean of differences was 0.26 ± 0.89 L/min with an error of 40.4%. In adult patients after cardiac surgery, including those with low cardiac output and arrhythmia CO-MBA is not interchangeable with the continuous thermodilution method via a PAC, when using a 30% error threshold.


Assuntos
Pressão Arterial , Procedimentos Cirúrgicos Cardíacos , Adulto , Humanos , Termodiluição/métodos , Artéria Pulmonar , Débito Cardíaco/fisiologia , Cuidados Críticos , Unidades de Terapia Intensiva , Reprodutibilidade dos Testes
17.
J Transl Med ; 20(1): 617, 2022 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-36564822

RESUMO

BACKGROUND: No direct approach assessing pulmonary vascular permeability exists in the current therapeutic strategy for patients with acute respiratory distress syndrome (ARDS). Transpulmonary thermodilution measures hemodynamic parameters such as pulmonary vascular permeability index and extravascular lung water, enabling clinicians to assess ARDS severity. The aim of this study is to explore a precise transpulmonary thermodilution-based criteria for quantifying the severity of lung injury using a clinically relevant septic-ARDS pig model. METHODS: Thirteen female pigs (weight: 31 ± 2 kg) were intubated, mechanically ventilated under anesthesia, and either assigned to septic shock-induced ARDS or control group. To confirm the development of ARDS, we performed computed tomography (CT) imaging in randomly selected animals. The pulmonary vascular permeability index, extravascular lung water, and other hemodynamic parameters were consecutively measured during the development of septic lung injury. Lung status was categorized as normal (partial pressure of oxygen/fraction of inspired oxygen ≥ 400), or injured at different degrees: pre-ARDS (300-400), mild-to-moderate ARDS (100-300), or severe ARDS (< 100). We also measured serum inflammatory cytokines and high mobility group box 1 levels during the experiment to explore the relationship of the pulmonary vascular permeability index with these inflammatory markers. RESULTS: Using CT image, we verified that animals subjected to ARDS presented an extent of consolidation in bilateral gravitationally dependent gradient that expands over time, with diffuse ground-glass opacification. Further, the post-mortem histopathological analysis for lung tissue identified the key features of diffuse alveolar damage in all animals subjected to ARDS. Both pulmonary vascular permeability index and extravascular lung water increased significantly, according to disease severity. Receiver operating characteristic analysis demonstrated that a cut-off value of 3.9 for the permeability index provided optimal sensitivity and specificity for predicting severe ARDS (area under the curve: 0.99, 95% confidence interval, 0.98-1.00; sensitivity = 100%, and specificity = 92.5%). The pulmonary vascular permeability index was superior in its diagnostic value than extravascular lung water. Furthermore, the pulmonary vascular permeability index was significantly associated with multiple parameters reflecting clinicopathological changes in animals with ARDS. CONCLUSION: The pulmonary vascular permeability index is an effective indicator to measure septic ARDS severity.


Assuntos
Lesão Pulmonar , Edema Pulmonar , Síndrome do Desconforto Respiratório , Choque Séptico , Infecção dos Ferimentos , Feminino , Suínos , Animais , Edema Pulmonar/complicações , Edema Pulmonar/diagnóstico , Termodiluição/métodos , Síndrome do Desconforto Respiratório/diagnóstico , Síndrome do Desconforto Respiratório/complicações , Pulmão/diagnóstico por imagem , Pulmão/irrigação sanguínea , Oxigênio
18.
Sci Rep ; 12(1): 11198, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35778523

RESUMO

In liver transplantation for end-stage liver failure, monitoring of continuous cardiac output (CCO) is used for circulatory management due to hemodynamic instability. CCO is often measured using the minimally invasive FloTrac/Vigileo system (FVS-CCO), instead of a highly invasive pulmonary artery catheter (PAC-CCO). The FVS has improved accuracy due to an updated cardiac output algorithm, but the effect of this change on the accuracy of FVS-CCO in liver transplantation is unclear. In this study, we assessed agreement between fourth-generation FVS-CCO and PAC-CCO in 20 patients aged ≥ 20 years who underwent scheduled or emergency liver transplantation at Kyoto University Hospital from September 2019 to June 2021. Consent was obtained before surgery and data were recorded throughout the surgical period. Pearson correlation coefficient (r), Bland-Altman and 4-quadrant plot analyses were performed on the extracted data. A total of 1517 PAC-CCO vs. FVS-CCO data pairs were obtained. The mean PAC-CCO was 8.73 L/min and the mean systemic vascular resistance was 617.5 dyne·s·cm-5, r was 0.48, bias was 1.62 L/min, the 95% limits of agreement were - 3.04 to 6.27, and the percentage error was 54.36%. These results show that agreement and trending between fourth-generation FVS-CCO and PAC-CCO are low in adult liver transplant recipients.


Assuntos
Doença Hepática Terminal , Transplante de Fígado , Adulto , Débito Cardíaco , Catéteres , Humanos , Estudos Prospectivos , Artéria Pulmonar/cirurgia , Termodiluição/métodos
19.
Ann Card Anaesth ; 25(3): 335-342, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35799563

RESUMO

Background: An ideal CO monitor should be noninvasive, cost effective, reproducible, reliable during various physiological states. Limited literature is available regarding the noninvasive CO monitoring in open chest surgeries. Aim: The aim of this study was to compare the CO measurement by Regional Impedance Cardiography (RIC) and Thermodilution (TD) method in patients undergoing off pump coronary artery bypass graft surgery (OPCAB). Settings and Design: We conducted a prospective observational comparative study of CO measurement by the noninvasive RIC method using the NICaS Hemodynamic Navigator system and the gold standard TD method using pulmonary artery catheter in patients undergoing OPCAB. A total of 150 data pair from the two CO monitoring techniques were taken from 15 patients between 40-70 years at various predefined time intervals of the surgery. Patients and Methods: We have tried to find out the accuracy, precision and cost effectiveness of the newer RIC technique. Mean CO, bias and precision were compared for each pair i.e.TD-CO and RIC-CO as recommended by Bland and Altman. The Sensitivity and specificity of cutoff value to predict change in TD-CO was used to create a Receiver operating characteristic or ROC curve. Results: Mean TD-CO values were around 4.52 ± 1.09 L/min, while mean RIC- CO values were around 4.77± 1.84 L/min. The difference in CO change was found to be statistically not significant (p value 0.667). The bias was small (-0.25). The Bland Altman plot revealed a mean difference of -0.25 litres. The RIC method had a sensitivity of 55.56 % and specificity of 33.33 % in predicting 15% change in CO of TD method and the total diagnostic accuracy was 46.67%. Conclusion: A fair correlation was found between the two techniques. The RIC method may be considered as a promising noninvasive, potentially low cost alternative to the TD technique of hemodynamic measurement.


Assuntos
Cardiografia de Impedância , Ponte de Artéria Coronária sem Circulação Extracorpórea , Débito Cardíaco/fisiologia , Cardiografia de Impedância/métodos , Cateterismo de Swan-Ganz , Humanos , Reprodutibilidade dos Testes , Termodiluição/métodos
20.
Crit Care ; 26(1): 202, 2022 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-35794612

RESUMO

BACKGROUND: The prognostic value of extravascular lung water (EVLW) measured by transpulmonary thermodilution (TPTD) in critically ill patients is debated. We performed a systematic review and meta-analysis of studies assessing the effects of TPTD-estimated EVLW on mortality in critically ill patients. METHODS: Cohort studies published in English from Embase, MEDLINE, and the Cochrane Database of Systematic Reviews from 1960 to 1 June 2021 were systematically searched. From eligible studies, the values of the odds ratio (OR) of EVLW as a risk factor for mortality, and the value of EVLW in survivors and non-survivors were extracted. Pooled OR were calculated from available studies. Mean differences and standard deviation of the EVLW between survivors and non-survivors were calculated. A random effects model was computed on the weighted mean differences across the two groups to estimate the pooled size effect. Subgroup analyses were performed to explore the possible sources of heterogeneity. RESULTS: Of the 18 studies included (1296 patients), OR could be extracted from 11 studies including 905 patients (464 survivors vs. 441 non-survivors), and 17 studies reported EVLW values of survivors and non-survivors, including 1246 patients (680 survivors vs. 566 non-survivors). The pooled OR of EVLW for mortality from eleven studies was 1.69 (95% confidence interval (CI) [1.22; 2.34], p < 0.0015). EVLW was significantly lower in survivors than non-survivors, with a mean difference of -4.97 mL/kg (95% CI [-6.54; -3.41], p < 0.001). The results regarding OR and mean differences were consistent in subgroup analyses. CONCLUSIONS: The value of EVLW measured by TPTD is associated with mortality in critically ill patients and is significantly higher in non-survivors than in survivors. This finding may also be interpreted as an indirect confirmation of the reliability of TPTD for estimating EVLW at the bedside. Nevertheless, our results should be considered cautiously due to the high risk of bias of many studies included in the meta-analysis and the low rating of certainty of evidence. Trial registration the study protocol was prospectively registered on PROSPERO: CRD42019126985.


Assuntos
Estado Terminal , Água Extravascular Pulmonar , Estado Terminal/mortalidade , Humanos , Prognóstico , Reprodutibilidade dos Testes , Termodiluição/métodos