Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 222
Filtrar
1.
Artigo em Chinês | MEDLINE | ID: mdl-37455112

RESUMO

Objective: This study was to investigate the main characteristics and related factors of wideband absorbance (WBA) in children with normal hearing and to obtain age-specific reference range of WBA. Methods: 384 children between 0-12 years old (615 ears) who visited the Beijing Children's Hospital, Capital Medical University from October 2019 to February 2021 were enrolled, including 230 males (376 ears) and 154 females (239 ears), with totally 306 left ears and 309 right ears. Wideband tympanometry (WBT) was performed and normative WBA data were analyzed by SPSS 24.0 statistical software. Repeated measures and multivariate analysis of variance were applied to the data from 16 points at 1/3-octave frequencies (226, 324, 408, 500, 667, 841, 1 000, 1 297, 1 682, 2 000, 2 670, 3 364, 4 000, 5 339, 6 727 and 8 000 Hz) to evaluate the effects of frequency, age, external auditory canal pressures, gender and ear on WBA. Results: According to the WBT frequency-absorbance curve, the subjects were divided into seven groups: 1-month old group, 2-month old group, 3-month old group, 4-5 month old group, 6-24 month old group,>2-6 year old group and>6-12 year old group. The WBA of normal-hearing children underwent a series of developmental changes with age at both ambient pressure and tympanometric peak pressures. WBA results for 1-month group and 2-month old group exhibited a multipeaked pattern, with the peaks occurring around 2 000 and 4 897 Hz, and a notch around 3 886 Hz. WBA results for 3-month group and 4-5 month old group exhibited a single broad-peaked pattern, with the peak occurring between 2 000-4 757 Hz. The WBA of 1-month old group to 4-5 month old group decreased gradually at low frequency (226-408 Hz) and 6 727 Hz, and increased at middle to high frequency (2 670-4 000 Hz). The WBA of 6-24 month old group were significantly lower than that of 2-month old group to 4-5 month old group at all frequencies except 3 364 and 4 000 Hz. WBA results for 6-24 month old group,>2-6 year old group and>6-12 year old group exhibited a single-peaked pattern, and the peak frequency of WBA moved to the lower frequency successively. From 6-24 month old group to>6-12 year old group, the WBA gradually increased at low to middle frequencies (667-2 670 Hz) and 8 000 Hz, and decreased at middle to high frequencies (3 364-5 339 Hz). Among the 16 frequencies of all age groups, the difference between WBA under ambient pressure and tympanometric peak pressure were -0.09-0.06, and 43.75%-81.25% frequency points had statistically significant difference, which was mainly manifested in that WBA under ambient pressure were lower than that under tympanometric peak pressure at 226-1 682 Hz. There was no significant ear effect on all of the age groups. Similarly, there was no significant gender effect except for 3-month old group and 4-5 month old group. Conclusions: The WBA of normal-hearing children measured at ambient pressure and tympanometric peak pressure varied across the frequencies with age from 1 month to 12 years old, and different frequencies followed different change patterns (increase vs. decrease) in WBA. There was also significant external auditory canal pressures effect on all of the age groups. The establishment of age-specific reference range of WBA for 0-12 years old normal-hearing children in this study would be useful for clinical practice of determining normative data regarding WBT.


Assuntos
Testes de Impedância Acústica , Orelha , Masculino , Feminino , Humanos , Criança , Recém-Nascido , Lactente , Pré-Escolar , Estudos Transversais , Testes de Impedância Acústica/métodos , Valores de Referência , Meato Acústico Externo
2.
J Int Adv Otol ; 19(2): 140-148, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36975086

RESUMO

BACKGROUND: Surgical tympanostomy tube insertion is a standard procedure in Otitis media with effusion after proper follow-up. During the surgery, the presence of serous or mucoid fluids, atelectatic tympanic membrane, or empty ear may be observed, despite all patients having the same diagnosis. A better method based on a non-invasive approach can help avoid unnecessary surgery. This study aimed to compare surgically confirmed otitis media with effusion with wideband tympanometry and absorbance tests. METHODS: A total of 122 children diagnosed with otitis media with effusion were included. Eighty healthy children were included as controls. Ears were divided into 4 groups: serous, mucoid, atelectasis, and empty. Resonance frequency, 226 Hz and 1000 Hz compliance, wideband peak pressure, and absorbance data were used for comparison. RESULTS: The most practical tests were the average of 500, 1000, and 2000 Hz absorbance according to positive likelihood ratio (4.8) and model 2 according to negative likelihood ratio (0.11). It was better than the standard 226 Hz and 1000 Hz compliance tests. Although some statistically significant parameters were observed between serous fluid and empty ear, they were not sufficiently impactful for a differential diagnosis. No parameter could help us differentiate between serous and mucous fluids. CONCLUSION: According to negative likelihood ratio (0.11), a person with normal middle ear is 9 times more likely to have negative test with the use of resonance frequency, wideband tympanometry, and average absorbance together. To differentiate serous fluid from the empty ear, using only 226 Hz or 1000 Hz compliance for surgical indication can potentially cause wrong decisions according to negative likelihood ratios.


Assuntos
Líquidos Corporais , Otite Média com Derrame , Criança , Humanos , Testes de Impedância Acústica/métodos , Otite Média com Derrame/diagnóstico , Otite Média com Derrame/cirurgia , Orelha Média , Membrana Timpânica
3.
J Craniofac Surg ; 34(3): e259-e263, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36728970

RESUMO

BACKGROUND: Many children with cleft palate also exhibit hearing loss and middle ear dysfunction, which could last for years. There are still arguments on how to treat this problem. This study aimed to evaluate the impact of a modified restoration of tensor veli palatine (TVP) on hearing and middle ear function in the cleft palate children. METHODS: This retrospective study was completed using records of the cleft palate children who received surgery in Peking Union Medical College Hospital from May 2013 to December 2020. They were divided into 2 groups: Group 1: children who received cleft palate surgery without specific restoration of TVP; Group 2: children who received palate surgery with a specific TVP restoration technique. Perioperative information was collected. The conductive auditory brainstem response and the 226-Hz tympanometry before and after the cleft surgery were compared intragroup and intergroup. RESULTS: Totally 42 children were included in this study, 21 children in each group. There were no significant differences considering clinical characteristics between the 2 groups. The modified TVP restoration didn't increase operation time or complication compared with no TVP restoration. Statistically, neither the auditory brainstem response air conduction hearing thresholds nor the 226-Hz tympanometry results had significant differences between the 2 groups after the surgery. CONCLUSIONS: This modified restoration of TVP was not time-consuming and did not increase complications. The beneficial effect of the modified TVP restoration on the hearing or the middle ear function of cleft palate children was uncertain around 6 months after surgery compared with no restoration.


Assuntos
Fissura Palatina , Criança , Humanos , Fissura Palatina/complicações , Estudos Retrospectivos , Audição , Testes de Impedância Acústica/métodos , Orelha Média/cirurgia
4.
Int J Pediatr Otorhinolaryngol ; 163: 111368, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36327914

RESUMO

OBJECTIVES: Although sound conduction mechanisms may influence by cochlear implantation (CI), it is not very clear whether, how, and to what extent these mechanisms may be influenced the pediatric population. Wideband tympanometry (WBT) is a sensitive tool to evaluate alternations in the middle ear mechanics in a wide frequency range. The current study aimed to explore CI's impacts on sound conduction across the middle ear cavity using WBT in pediatrics. METHODS: In a prospective design, 35 unilaterally implanted children (<24 months of age) with normal temporal bone anatomy were included in this study. Traditional tympanometry (226-Hz) and WBT measures were compared for each child in the implanted and non-implanted ears preoperatively and three months postoperatively. RESULTS: No significant changes in the "static acoustic admittance" and "peak pressure" parameters were observed between the pre-CI and post-CI conditions in the implanted and non-implanted ears in the 226-Hz tympanometry test. Wideband absorbance recordings before CI surgery exhibited a double-peaked pattern over a frequency range of 250 to 8000 Hz. The pre- and postoperative acoustic energy absorbance comparisons indicated a significantly reduced mid-frequency (1260 to 3175 Hz) and high-frequency (5040 to 8000 Hz) absorbance in the implanted ears. However, our results indicated no significant differences in sound absorbance between the pre- and postoperative conditions in non-implanted ears. CONCLUSION: Our findings suggested that WBT is a more sensitive method than traditional tympanometry for monitoring the mechanical status of the middle ear after cochlear implantation in pediatrics. Cochlear implantation in young children can significantly reduce mid- and high-frequency acoustic absorbance measured by WBT.


Assuntos
Implante Coclear , Criança , Humanos , Pré-Escolar , Estudos Prospectivos , Orelha Média/cirurgia , Testes de Impedância Acústica/métodos , Som
5.
Artigo em Inglês | MEDLINE | ID: mdl-35190086

RESUMO

INTRODUCTION: The influence of isolated nasal septum deviation (NSD) in the Eustachian Tube (ET) function is still undetermined. OBJECTIVE: compare ET function between patients with severe NSD and patients with adequate nasal patency in terms of symptomology and objective exams and assess the impact of septoplasty in ET function in patients with severe NSD. METHODS AND METHODOLOGY: a prospective study was conducted. In the first phase of the study, two opportunistic samples were selected: 35 patients with severe NSD for group A and 35 patients with adequate nasal patency for group B. Both groups were evaluated through Nasal obstruction Subjective Questionnaire (NOSE) and ET dysfunction questionnaire 7 (ETDQ7) -, and through two objective exams to assess ET function - tympanometry, and tubomanometry (TMM); results were compared between group A and B. In the second phase of the study, the patients from group A underwent septoplasty and were re-evaluated through ETDQ7, tympanometry and TMM; results were compared before and after surgery. RESULTS: we found a statistically significant difference between patients with NSD and patients with adequate nasal patency in NOSE and ETDQ7 (higher scores in the latter), and TMM (worse results in patients with NSD); the difference in tympanometry was not statistically significant. The side of the NSD did not correlate with the side of the dysfunction. After septoplasty, patients from group A had statistically significant lower scores in ETDQ7 and a lower proportion of patients with findings compatible with ET dysfunction using TMM. CONCLUSION: according to our results, severe NSD alone is a cause of ET dysfunction; septal surgery might improve ET function in these patients.


Assuntos
Testes de Impedância Acústica , Tuba Auditiva , Testes de Impedância Acústica/métodos , Estudos de Casos e Controles , Humanos , Septo Nasal/cirurgia , Estudos Prospectivos
6.
J Biomech Eng ; 144(3)2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34505125

RESUMO

Current clinical practice is often unable to identify the causes of conductive hearing loss in the middle ear with sufficient certainty without exploratory surgery. Besides the large uncertainties due to interindividual variances, only partially understood cause-effect principles are a major reason for the hesitant use of objective methods such as wideband tympanometry in diagnosis, despite their high sensitivity to pathological changes. For a better understanding of objective metrics of the middle ear, this study presents a model that can be used to reproduce characteristic changes in metrics of the middle ear by altering local physical model parameters linked to the anatomical causes of a pathology. A finite-element model is, therefore, fitted with an adaptive parameter identification algorithm to results of a temporal bone study with stepwise and systematically prepared pathologies. The fitted model is able to reproduce well the measured quantities reflectance, impedance, umbo and stapes transfer function for normal ears and ears with otosclerosis, malleus fixation, and disarticulation. In addition to a good representation of the characteristic influences of the pathologies in the measured quantities, a clear assignment of identified model parameters and pathologies consistent with previous studies is achieved. The identification results highlight the importance of the local stiffness and damping values in the middle ear for correct mapping of pathological characteristics and address the challenges of limited measurement data and wide parameter ranges from the literature. The great sensitivity of the model with respect to pathologies indicates a high potential for application in model-based diagnosis.


Assuntos
Testes de Impedância Acústica , Orelha Média , Testes de Impedância Acústica/efeitos adversos , Testes de Impedância Acústica/métodos , Algoritmos , Orelha Média/patologia , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/etiologia , Humanos
7.
Eur Arch Otorhinolaryngol ; 279(4): 1831-1841, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34009459

RESUMO

PURPOSE: The main purpose of this study was to investigate the usefulness of wide band tympanometry (WBT) as a diagnostic tool for Ménière's disease (MD) by comparing differences in absorbance measures between normal hearing ears and patient diagnosed with MD. METHODS: We conducted a retrospective case-control study. From a cohort of 116 patients diagnosed with Ménière disease, 52 MD patients and 99 normal hearing adults with no history of otological disease served as subjects. Wideband tympanometry was conducted using at Titan Impedance module and audiometry was performed with a MADSEN Astera2. Mean energy absorbance curves with 95% confidence intervals were computed across cases with MD and controls in the frequency range 226-8000 Hz. An overall test for difference between curves of cases and controls was calculated by multivariate analysis of variance. RESULTS: The MD group and the subpopulations of MD patients who fulfilled the International criteria for MD showed a statistically significant lower absorbance at tympanic peak pressure compared to the control group (p < 0.001). No overlap of confidence intervals between mean curves was found within the frequency range of 2000-4000 Hz. CONCLUSION: Absorbance measures obtained by WBT were able to distinguish between MD ears and normal ears within the frequency range of 2000-4000 Hz. The results indicate that WBT potentially could be a useful and simple non-invasive diagnostic tool for MD. However, more research on the association between absorbance measures and inner ear pathologies is needed.


Assuntos
Orelha Interna , Doença de Meniere , Testes de Impedância Acústica/métodos , Adulto , Estudos de Casos e Controles , Humanos , Doença de Meniere/diagnóstico , Estudos Retrospectivos
8.
Otolaryngol Head Neck Surg ; 165(4): 491-492, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33687296

RESUMO

Interpretation of tympanometry commonly relies on the historical convention of classifying findings according to large and arbitrary threshold shifts of tympanometric peak pressure (TPP). This convention had value for prior generations of otolaryngologists in diagnosing severe, chronic middle ear disease requiring surgical intervention but may not be well suited for the present-day evaluation of less severe disease. The existing definition of a type C curve (less than -100 daPa) is likely insensitive to detect subtle abnormalities, including some presentations of obstructive eustachian tube dysfunction. The accuracy of clinical diagnosis may be improved by reporting the absolute values of TPP and moving beyond classification according to arbitrary thresholds.


Assuntos
Testes de Impedância Acústica/métodos , Otopatias/diagnóstico , Otopatias/fisiopatologia , Orelha Média/fisiopatologia , Humanos
10.
Otolaryngol Head Neck Surg ; 165(3): 465-469, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33290173

RESUMO

OBJECTIVE: To determine if wideband tympanometry (WBT) can differentiate types of middle ear effusion (MEE): serous, mucoid, and purulent. STUDY DESIGN: Prospective cohort study. SETTING: Tertiary care children's hospital. METHODS: Children who met American Academy of Otolaryngology-Head and Neck Surgery's guidelines for ventilation tube insertion had WBT after anesthesia induction but before tympanotomy. MEE was categorized into 1 of 4 comparison groups: serous effusion, mucoid effusion, purulent effusion, or no effusion. WBT measurements were averaged to 16 one-third octave frequency bands, and comparison of the absorbance patterns for each MEE type was performed through a linear mixed effects model. RESULTS: A total of 118 children (211 ears) were included: 47 females (39.8%) and 71 males (60.2%). The mean age was 2.73 years (95% CI, 2.25-3.22); mean weight, 14.35 kg (95% CI, 12.85-15.85); and mean Z score, 1.13 (95% CI, -0.64 to 2.33). Effusions included 61 mucoid (28.9%), 30 purulent (14.2%), and 14 serous (6.6%), with 106 (50.2%) having no effusion. No significant differences were found for sex, race, age, weight, or Z score among the 4 types of effusion (P < .05). WBT showed a significant difference in median absorption among the effusion groups (P < .001), with a medium effect size of 0.35. CONCLUSIONS: WBT has potential use to differentiate types of MEE and should be studied further as a tool for investigating how the natural history and management of serous and mucoid effusions may differ.


Assuntos
Testes de Impedância Acústica/métodos , Otite Média com Derrame/diagnóstico , Pré-Escolar , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Estudos Prospectivos , West Virginia
11.
J Laryngol Otol ; 134(12): 1052-1059, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33272331

RESUMO

OBJECTIVE: To assess the effect on hearing of non-functioning ventilation tubes due to blockage during the first six months post-operatively, using UK national guidelines. METHOD: A prospective, observational study was conducted on 37 children who underwent bilateral ventilation tube insertion. Air and bone conduction thresholds were measured before and following surgery, and at one, three and six months post-operatively. Tube non-function was assessed by tympanometry supported by otoscopy. RESULTS: Post-operatively, an average of 21 per cent of ventilation tubes were non-functioning. Ears with non-functioning tubes had significantly (p = 0.0001) poorer mean air conduction thresholds than functioning tubes, with a magnitude of 6 dB HL. Ears with otorrhoea were most affected (15 per cent). At any one visit, the air-bone gap was closed to 10 dB or less in 76 per cent of ears. Non-functioning tubes reduced this to 56 per cent. Compared with tympanometry, otoscopy underdiagnosed tube non-function due to blockage by 22 per cent. CONCLUSION: Non-functioning of ventilation tubes occurs frequently and can be missed on otoscopy. Although it is associated with poorer air conduction thresholds, the magnitude of this difference is unlikely to warrant further intervention unless there is otorrhoea or recurrence of bilateral hearing impairment.


Assuntos
Otopatias/cirurgia , Perda Auditiva Bilateral/cirurgia , Audição/fisiologia , Ventilação da Orelha Média/métodos , Otite Média com Derrame/cirurgia , Testes de Impedância Acústica/métodos , Adolescente , Limiar Auditivo/fisiologia , Condução Óssea/fisiologia , Criança , Pré-Escolar , Feminino , Perda Auditiva Bilateral/etiologia , Humanos , Masculino , Ventilação da Orelha Média/estatística & dados numéricos , Otite Média com Derrame/complicações , Otoscopia/métodos , Período Pós-Operatório , Estudos Prospectivos , Recidiva
12.
Lang Speech Hear Serv Sch ; 51(2): 345-352, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32216695

RESUMO

Purpose The purpose of this study was to review quality benchmarks from hearing screening programs conducted at local Head Start centers and preschool and elementary schools associated with our university training programs. Method Hearing screening results from 6,043 children were reviewed. Hearing screening was accomplished using either distortion product otoacoustic emissions (DPOAEs) at Head Start centers, pure-tone audiometry at preschool and elementary schools, and tympanometry at all settings. All children who did not pass the initial screening were screened a second time. Referrals were made if a child did not pass the automated DPOAE pass criteria for one ear, failed at least one pure-tone frequency for one ear, or had abnormal tympanometry in one ear. Results Refer rates were 10.9% for DPOAEs and 11.4% for pure-tone audiometry and tympanometry, with an overall refer rate of 11%. Conclusions Our hearing screening program review yielded refer rates that are similar to other published reports for this population. Presently, there are no published target refer rates for hearing screening programs in preschool and elementary schools. Although we were not able to complete other program quality benchmark indicators including sensitivity and specificity, these data may support benchmarks for other hearing screening programs.


Assuntos
Testes de Impedância Acústica/métodos , Audiometria de Tons Puros/métodos , Intervenção Educacional Precoce , Perda Auditiva/diagnóstico , Programas de Rastreamento/métodos , Emissões Otoacústicas Espontâneas , Instituições Acadêmicas , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Nova Orleans/epidemiologia , Avaliação de Programas e Projetos de Saúde , Sensibilidade e Especificidade
13.
J Colloid Interface Sci ; 559: 65-75, 2020 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-31610306

RESUMO

Electroactive nanofibrous scaffold is a vital tool for the study of the various biological research fields from bioelectronics to regenerative medicine, which can provide cell preferable 3D nanofiber architecture and programmed electrical signal. However, intrinsic non-biodegradability is a major problem that hinders its widespread application in the clinic. Herein, we designed, synthesized, and characterized shell/core poly (3,4-ethylenedioxythiophene) (PEDOT)/chitosan (CS) nanofibers by combining the electrospinning and recrystallization processes. Upon incorporating a trace amount of PEDOT (1.0 wt%), the resultant PEDOT/CS nanofibers exhibited low interfacial charge transfer impedance, high electrochemical stability, high electrical conductivity (up to 0.1945 S/cm), and ultrasensitive piezoelectric property (output voltage of 22.5 mV by a human hair prodding). With such unique electrical and conductive properties, PEDOT/CS nanofibers were further applied to brain neuroglioma cells (BNCs) to stimulate their adhesion, proliferation, growth, and development under an optimal external electrical stimulation (ES) and a pulse voltage of 400 mV/cm. ES-responsive PEDOT/CS nanofibers indeed promoted BNCs growth and development as indicated by a large number and density of axons. The synergetic interplay between external ES and piezoelectric voltage demonstrates new PEDOT-based nanofibers as implantable electroactive scaffolds for numerous applications in nerve tissue engineering, human health monitoring, brain mantle information extraction, and degradable microelectronic devices.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes/química , Quitosana/química , Condutividade Elétrica , Nanofibras/química , Polímeros/química , Testes de Impedância Acústica/métodos , Axônios/metabolismo , Materiais Biocompatíveis/química , Adesão Celular/efeitos dos fármacos , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Cristalização , Estimulação Elétrica/métodos , Glioma/metabolismo , Humanos
14.
Pan Afr Med J ; 34: 57, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31803343

RESUMO

INTRODUCTION: Chronic suppurative otitis media is a global middle ear disease with quality of life as economic implications, which are worse felt in low and middle income (LAMI) countries; thus the need for myringoplasty. This study aimed to explore audiological function in a group of adults following myringoplasty in South Africa, with an exploration of the possible influence of factors such as HIV/AIDS and type of surgical technique on hearing outcomes. METHODS: Within a retrospective chart review research design, 41 participant files for a six-year period from two academic hospitals in Johannesburg, South Africa, were reviewed. Data were analysed using both descriptive and inferential statistics. RESULTS: Participant files comprised of 16 males and 25 females between 18-63 years. Findings revealed that clinically, overall hearing improved post-operatively, as indicated by improved tympanometry findings, pure tone air-conduction and speech reception thresholds. Descriptively, the predictors of improved hearing outcomes post-operatively appeared to be HIV negative status and butterfly cartilage inlay surgery as a surgical technique adopted. Although clinically, hearing outcomes improved post-operatively at all air-conduction frequencies tested; these clinical improvements were only statistically significant at specific frequencies. CONCLUSION: Current findings provide useful initial evidence on the benefits of myringoplasty from the South African context; particularly because of the HIV/AIDS prevalence and its potential influence on middle ear disease and its management. Prospective efficacy studies with bigger sample sizes are recommended, with early identification strategies for middle ear disease to reduce the need for myringoplasty seriously considered bearing in mind the resource constraints.


Assuntos
Testes de Impedância Acústica/métodos , Miringoplastia/métodos , Otite Média Supurativa/cirurgia , Adolescente , Adulto , Doença Crônica , Feminino , Infecções por HIV/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Otite Média Supurativa/fisiopatologia , Qualidade de Vida , Estudos Retrospectivos , África do Sul , Resultado do Tratamento , Adulto Jovem
15.
Biomed Res Int ; 2019: 2070548, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31485439

RESUMO

OBJECTIVES: The purpose of this study was to explore the effectiveness of wideband acoustic immittance (WAI) in the diagnosis of otosclerosis by comparing the differences in the energy reflectance (ER) of WAI between patients with otosclerosis and age- and gender-matched normal hearing controls in the Chinese population. METHODS: Twenty surgically confirmed otosclerotic ears were included in the otosclerotic group. The ER of WAI at ambient and peak pressures, resonance frequency, and 226-Hz tympanogram were collected prior to surgery using a Titan hearing test platform (Interacoustics A/S, Middelfart, Denmark). All diagnoses of otosclerosis in the tested ear were confirmed by surgery after the measurements. Thirteen normal adults (26 ears) who were age- and gender-matched with the otosclerotic patients were included as the control group. RESULTS: At peak pressure, the ERs of otosclerotic patients were higher than those of the control group for frequencies less than 4,000Hz and were lower for frequencies greater than 4,000Hz. In addition, within the analyzed frequencies, the differences observed at 2,520Hz was statistically significant (p<0.05/16=0.003, Bonferroni corrected). At ambient pressure, the differences observed at 1,260 and 6,350Hz were statistically significant (p<0.05/16=0.003, Bonferroni corrected). Although the differences between the otosclerotic and control groups exhibited similar trends to those in studies implemented in Caucasian populations, the norms in the present study in the control group were different from those in the Caucasian populations, suggesting racial differences in WAI test results. Regarding the middle ear resonance frequency, no significant difference was observed between the two groups (P>0.05). CONCLUSION: WAI can provide valuable information for the diagnosis of otosclerosis in the Chinese population. Norms and diagnostic criteria corresponding to the patient's racial group are necessary to improve the efficiency of WAI in the diagnosis of otosclerosis.


Assuntos
Otosclerose/fisiopatologia , Testes de Impedância Acústica/métodos , Adolescente , Adulto , Povo Asiático , Audiometria/métodos , Orelha Média/fisiopatologia , Feminino , Audição/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , População Branca , Adulto Jovem
16.
Am J Audiol ; 28(2S): 516-523, 2019 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-31461338

RESUMO

Purpose Numerous studies are testimony to the pivotal role of multicomponent tympanometry in diagnosis and differential diagnosis of auditory pathologies, not only of the middle ear but also the inner ear. Repeated measurements using multicomponent tympanometry have been used as a measure for stapedial tendon preservation during middle ear surgeries. However, such applications would produce reliable results only when multicomponent tympanometry produces replicable results across sessions. Nonetheless, there is dearth of studies exploring the test-retest repeatability of multicomponent tympanometry across multiple sessions using various probe tones. Therefore, this study aimed at examining the test-retest reliability of multicomponent tympanometry across 10 different sessions for 226-, 678-, and 1000-Hz probe-tone frequencies. Method The study included 28 healthy adults in the age range of 18 to 25 years. All participants underwent multicomponent (susceptance and conductance) tympanometry using 226-, 678-, and 1000-Hz probe tones. Results Multicomponent tympanometry showed excellent test-retest reliability for all parameters of 226- and 678-Hz probe tones. The probe tone of 1000 Hz produced excellent test-retest reliability for most of the parameters. Conclusions The clinical recording of multicomponent tympanometry over multiple sessions is more reliable when using 226- and 678-Hz probe tones. Hence, these probe tones lend themselves to possible applications requiring multiple recordings, such as evaluation of treatment outcomes or preservation of middle ear structures during surgery.


Assuntos
Testes de Impedância Acústica/métodos , Orelha Interna/fisiologia , Orelha Média/fisiologia , Adolescente , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
17.
Eur Arch Otorhinolaryngol ; 276(9): 2433-2439, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31175454

RESUMO

PURPOSE: Wideband-tympanometry (WBT) could give more informative data about the tympanic condition than the conventional tympanometry. In the actual literature, the clinical profit of wideband-tympanometry in pediatric audiological settings is not well evaluated. The aim of this study was to analyze the additional clinical benefit. METHODS: 150 children (281 ears) with normal hearing, at the age from 11 days up to 14;10 years, checked with pure tone audiometry or auditory brainstem responses (ABR) participated in this retrospective study. We divided in four age ranges (≤ 6 month; > 6 month ≤ 3 years; > 3 years ≤ 11 years; > 11 years). All children were evaluated with ENT examination including ear microscopy, conventional 226-Hz or 1000-Hz tympanometry and WBT. Ear canal volumes were determined. RESULTS: Compared with literature data, our patients aged ≤ 3 years showed smaller mean ear canal volumes (≤ 4 ml). We found a good statistical correlation between the WBT-results and 1000-Hz tympanometry but a rare correlation between WBT-results and ear microscopic findings. In the patients with pathologic ear microscopic results in all groups of age, a significant reduction of WBT-absorbance in 1000 Hz and 2000 Hz was found. CONCLUSIONS: This study confirms that WBT collects additive data to detect the correct middle ear status. In pediatric audiology, WBT is an additional useful method to value middle ear problems and to analyze the character of infantile hearing loss. Standard guidelines for the interpretation of the pediatric population are needed. Hence, it will be necessary to determine these findings in a larger number of infantile ears.


Assuntos
Testes de Impedância Acústica/métodos , Perda Auditiva/diagnóstico , Adolescente , Fatores Etários , Audiologia , Audiometria de Tons Puros/métodos , Criança , Pré-Escolar , Meato Acústico Externo/anatomia & histologia , Potenciais Evocados Auditivos do Tronco Encefálico , Feminino , Perda Auditiva/etiologia , Humanos , Lactente , Masculino , Otite Média com Derrame/complicações , Otite Média com Derrame/diagnóstico , Estudos Retrospectivos , Membrana Timpânica
18.
Am J Otolaryngol ; 40(4): 512-519, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31006501

RESUMO

OBJECTIVE: We aim to investigate hearing sensitivity and wideband tympanometry results in bone cement ossiculoplasty cases in present study. STUDY DESIGN: A prospective study. SETTING: Ossiculoplasty patients were grouped according to the anatomical location of bone cement application by surgery note. Ossiculoplasty and tympanoplasty patients were retrospectively invited to the clinic and evaluated. 30 bone cement ossiculoplasty cases as well as 30 Type I tympanoplasty cases (intact ossicular chain) and 30 healthy controls were included in the study and Wideband Tympanometry was performed. Tympanometric peak pressure, equivalent middle ear volume, static admittance, tympanogram width, resonance frequency, average wideband tympanometry and absorbance measurements were analyzed. RESULTS: A statistically significant improvement was observed in the hearing levels of all ossiculoplasty and type I tympanoplasty patients (p < 0.05). Bone cement ossiculoplasty groups demonstrated the remarkable differences than the type I tympanoplasty and control group in Wideband Tympanometry test parameters. In some parameters, malleus-stapes and manubriostapedioplasty groups demonstrated similarities to Type I tympanoplasty and control groups. CONCLUSION: Bone cement is an effective application for ossiculoplasty. Wideband tympanometry is a promising method for the evaluation of the middle ear dynamics.


Assuntos
Testes de Impedância Acústica/métodos , Cimentos Ósseos , Ossículos da Orelha/cirurgia , Orelha Média/fisiopatologia , Audição , Timpanoplastia/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
19.
Braz. j. otorhinolaryngol. (Impr.) ; 85(2): 193-198, Mar.-Apr. 2019. graf
Artigo em Inglês | LILACS | ID: biblio-1001557

RESUMO

Abstract Introduction: Tympanometry is currently the most frequently used tool for assessing the status of the middle ear, commonly assessed using a single 226 Hz tone. However, the use of the Acoustic Immittance Measures with a wideband stimulus is a promising high-resolution evaluation, especially in individuals known to have middle ear alterations, such as Down syndrome patients. Objective: The aim of this study was to analyze the acoustic absorbance measurements in children with Down syndrome. Methods: Cross-sectional study, approved by the institution's ethics committee. Data were collected from 30 children, with a mean age of 8.4 years, 15 with Down syndrome (DS-study group) and 15 children with typical development and no hearing complaints (control group). Energy absorbance was measured at frequencies of 226-8000 Hz at ambient pressure and at peak pressure as a function of frequency using TITAN equipment. Statistical analysis was performed using the established level of statistical significance of 5%. Results: With the 226 Hz probe tone, 30 ears of the control group and 22 of the study group exhibited Type A tympanograms, whereas Type B was observed in eight children in the study group. The mean acoustic absorbance ratio of the study group was lower than that of the control group at frequencies centered at 2520 Hz (p = 0.008) for those with normal tympanometry results, and 226-4000 Hz (p < 0.03) for those with a Type B tympanometry curve. Conclusion: The low energy absorption in the presence of normal tympanograms in children with Down syndrome may suggest middle ear abnormalities.


Resumo Introdução: A timpanometria é a ferramenta mais usada para avaliar o status da orelha média, comumente avaliada por meio de uma única frequência com o tom de 226 Hz. No entanto, o uso da medida de imitância acústica com estímulo de banda larga é uma avaliação de alta resolução promissora, especialmente em pacientes conhecidos por frequentemente apresentar alterações da orelha média, como na síndrome de Down. Objetivo: Analisar as medidas de absorvância acústica em crianças com síndrome de Down. Método: Estudo transversal, aprovado pelo comitê de ética da instituição. Foram coletados dados de 30 crianças, com idade média de 8,4 anos, sendo 15 com síndrome de Down (SD-grupo de estudo) e 15 crianças desenvolvimento típico e sem queixas auditivas (grupo controle). A absorvância de energia foi medida nas frequências de 226-8.000 Hz à pressão ambiente e no pico de pressão em função da frequência, usou-se o equipamento Titan. A análise estatística foi feita com o nível de significância estatística adotado de 5%. Resultados: Com o tom de sonda de 226 Hz foram observadas 30 orelhas do grupo controle e 22 do grupo estudo com timpanometria Tipo A e o Tipo B foi observado apenas em oito crianças do grupo estudo. A razão média de absorvância acústica do grupo estudo foi menor do que a do controle nas frequências centradas em 2.520 Hz (p = 0,008) para aqueles com resultados timpanométricos normais e de 226-4.000 Hz (p < 0,03) para aqueles com curva timpanométrica Tipo B. Conclusão: A baixa absorção de energia na presença de timpanogramas normais nas crianças com síndrome de Down pode sugerir anormalidades na orelha média.


Assuntos
Humanos , Masculino , Feminino , Criança , Testes de Impedância Acústica/métodos , Síndrome de Down/fisiopatologia , Orelha Média/fisiopatologia , Valores de Referência , Estudos de Casos e Controles , Estudos Transversais , Estatísticas não Paramétricas , Otopatias/diagnóstico , Otopatias/fisiopatologia
20.
J Craniofac Surg ; 30(4): 1187-1190, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30865109

RESUMO

Our study aimed to investigate the effects of different intubation devices on middle ear pressure (MEP) dynamics by evaluating MEP during stages of anesthesia.Sixty-one consecutive patients were randomly assigned to 2 groups: the classical endotracheal intubation group and the Baska Mask (a new laryngeal mask [LMA]) group. All patients received the same anesthesia protocol. The right and left MEP values of the patients were measured and recorded preoperatively, during the induction of anesthesia, at the time of intubation and at 5th minute of anesthesia.In group 1, the pressure values measured in the right ear during anesthesia induction, at the time of intubation and at 5th minute of anesthesia were 10.97 ±â€Š27.06, 16.77 ±â€Š29.40, and 21.64 ±â€Š90.31, respectively, compared to left ear values of 8.61 ±â€Š26.39, 18.77 ±â€Š37.84, and 38.61 ±â€Š56.96 daPa, respectively. In group 2, MEP values measured in the right ear during anesthesia induction, at the time of intubation, and at 5th minute of anesthesia were 9.53 ±â€Š20.43, 22.30 ±â€Š41.50, and 20.60 ±â€Š46.85 daPa, respectively, compared to left ear values of -4.26 ±â€Š25.17, 6.20 ±â€Š26.56, and 30.30 ± 65.17 daPa, respectively. MEP was statistically significantly increased in the classical endotracheal intubation group compared to the LMA group.We found that the increase in pressure is lower in patients receiving LMA compared to classical endotracheal intubation. The Baska Mask LMA is recommended in selected patients to prevent complications of MEP elevation.


Assuntos
Testes de Impedância Acústica/métodos , Anestesia Geral/efeitos adversos , Orelha Média/fisiopatologia , Intubação Intratraqueal , Máscaras Laríngeas , Procedimentos Cirúrgicos Nasais/efeitos adversos , Complicações Pós-Operatórias/prevenção & controle , Adulto , Anestesia Geral/métodos , Feminino , Humanos , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Nasais/métodos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Pressão , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA