Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
J Vasc Interv Radiol ; 35(3): 409-415, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38008376

RESUMO

PURPOSE: To evaluate the impact of virtual injection software (VIS) use during cone-beam computed tomography (CT)-guided prostatic artery embolization (PAE) on both patient radiation exposure and procedural time. MATERIALS AND METHODS: This institutional review board (IRB)-approved comparative retrospective study analyzed the treatment at a single institution of 131 consecutive patients from January 2020 to May 2022. Cone-beam CT was used with (Group 1, 77/131; 58.8%) or without VIS (Group 2, 54/131, 41.2%). Radiation exposure (number of digital subtraction angiography [DSA] procedures), dose area product (DAP), total air kerma (AK), peak skin dose (PSD), fluoroscopy time (FT), and procedure time (PT) were recorded. The influences of age, body mass index, radial access, and use of VIS were assessed. RESULTS: In bivariate analysis, VIS use (Group 1) showed reduction in the number of DSA procedures (8.6 ± 3.7 vs 16.8 ± 4.3; P < .001), DAP (110.4 Gy·cm2 ± 46.8 vs 140.5 Gy·cm2 ± 61; P < .01), AK (642 mGy ± 451 vs 1,150 mGy ± 637; P = .01), PSD (358 mGy ± 251 vs 860 mGy ± 510; P = .001), FT (35.6 minutes ± 15.4 vs 46.6 minutes ± 20; P = .001), and PT (94.6 minutes ± 41.3 vs 115.2 minutes ± 39.6, P = .005) compared to those in Group 2. In multivariate analysis, AK, PSD, FT, and PT reductions were associated with VIS use (P < .001, P < .001, P = .001, and P = .006, respectively). CONCLUSIONS: The use of VIS during PAE performed under cone-beam CT guidance led to significant reduction in patient radiation exposure and procedural time.


Assuntos
Embolização Terapêutica , Hiperplasia Prostática , Exposição à Radiação , Masculino , Humanos , Embolização Terapêutica/efeitos adversos , Próstata/diagnóstico por imagem , Próstata/irrigação sanguínea , Estudos Retrospectivos , Hiperplasia Prostática/terapia , Artérias/diagnóstico por imagem , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Software , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/métodos , Doses de Radiação , Fluoroscopia
2.
Diagn Interv Imaging ; 104(7-8): 368-372, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36973119

RESUMO

PURPOSE: The purpose of this study was to evaluate the safety and efficacy of middle meningeal artery embolization (MMAE) performed under cone-beam computed tomography (CBCT) augmented guidance in patients with cancer. MATERIALS AND METHODS: Eleven patients with cancer (seven women, four men; median age, 75 years; age range: 42-87 years) who underwent 17 MMAEs under CBCT with a combination of particles and coils for chronic subdural hematoma (SDH) (n = 6), postoperative SDH (n = 3), or preoperative embolization of meningeal tumor (n = 2) from 2022 to 2023 were included. Technical success, fluoroscopy time (FT), reference dose (RD), kerma area product (KAP) were analyzed. Adverse events and outcomes were recorded. RESULTS: The technical success rate was 100% (17/17). Median MMAE procedure duration was 82 min (interquartile range [IQR]: 70, 95; range: 63-108 min). The median FT was 24 min (IQR: 15, 48; range: 21.5-37.5 min); the median RD was 364 mGy (IQR: 37, 684; range: 131.5-444.5 mGy); and the median KAP was 46.4 Gy.cm2 (9.6, 104.5; range: 30.2-56.6 Gy.cm2). No further interventions were needed. The adverse event rate was 9% (1/11), with one pseudoaneurysm at the puncture site in a patient with thrombocytopenia, which was treated by stenting. The median follow-up was 48 days (IQR; 14, 251; range: 18.5-91 days]. SDH reduced in 11 of 15 SDHs (73%) as evidenced by follow-up imaging, with a size reduction greater than 50% in 10/15 SDHs (67%) . CONCLUSION: MMAE under CBCT is a highly effective treatment option, but appropriate patient selection and careful consideration of potential risks and benefits is important for optimal patient outcomes.


Assuntos
Embolização Terapêutica , Neoplasias , Masculino , Humanos , Feminino , Idoso , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Artérias Meníngeas/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/métodos , Embolização Terapêutica/métodos , Resultado do Tratamento , Estudos Retrospectivos
3.
J Stomatol Oral Maxillofac Surg ; 124(2): 101304, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36208836

RESUMO

BACKGROUND: In clinical practice, it is risky to extract bone-impacted teeth and they're prone to a variety of complications, such as pathological fracture, adjacent tooth fracture, maxillary sinus perforation, and so on, making it difficult for clinicians to decide whether to extract them. PURPOSE: In order to illustrate our opinions on the possibility of extracting full third molars (M3), 360 examples of complete third molars were analyzed in this study. MATERIALS AND METHOD: We investigated 2189 patients, and 261 of them provided CBCT images of 360 teeth. assessing the degree of second molar(M2) root absorption in connection to age, impacted relationship, contact part, calculating the odds ratio (OR) and 95% confidence interval using the Logistic regression analysis equation. RESULT: Bone-impacted M3 occurred in 11.92% (261/2189) of patients with "impacted teeth" diagnoses. There was a significant difference between the occurrence of M2ERR and the contact parts (P value<0.001), and only the type of vertical impaction differed significantly from Level 3 (P < 0.05). CONCLUSIONS: 1) M3 should be removed if root resorption has not occurred in M2. 2) Root resorption is more likely to occur when M3 crown and M2 apical contact. 3) Enough experience, precise preoperative assessment can reduce the dangers to a minimum.


Assuntos
Reabsorção da Raiz , Dente Impactado , Humanos , Estudos Retrospectivos , Reabsorção da Raiz/complicações , Reabsorção da Raiz/epidemiologia , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/métodos , Dente Molar , Dente Serotino/cirurgia , Dente Impactado/diagnóstico , Dente Impactado/epidemiologia , Dente Impactado/cirurgia
4.
Artigo em Inglês | MEDLINE | ID: mdl-35914862

RESUMO

This study sought to assess the cytotoxicity, genotoxicity, and immunohistochemical (IHC) expression of p53 in the oral mucosal epithelium of adults following cone-beam computed tomography (CBCT). This before-and-after observational study evaluated 30 patients (15 males and 15 females); mean age 35 years, who required CBCT. Exfoliating epithelial cells of the buccal mucosa were collected with a cotton swab immediately before and 10 days after CBCT. Following Papanicolaou staining, genotoxicity was evaluated by the micronucleus assay. The frequencies of pyknosis, karyorrhexis, karyolysis, budding and binucleation as cytotoxicity factors were also recorded. Expression of p53 was evaluated by IHC staining. Data were analyzed by paired samples t-test. Micronucleated cells, pyknosis, karyorrhexis, karyolysis, budding, cytotoxicity, and expression of p53 increased significantly after CBCT. CBCT exerts genotoxic and cytotoxic effects and leads to overexpression of p53 protein in the oral buccal mucosal cells.


Assuntos
Mucosa Bucal , Proteína Supressora de Tumor p53 , Adulto , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Dano ao DNA , Epitélio , Feminino , Humanos , Masculino , Testes para Micronúcleos , Proteína Supressora de Tumor p53/genética
5.
Technol Cancer Res Treat ; 20: 15330338211016472, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34184567

RESUMO

OBJECTIVES: This study performed dosimetry studies and secondary cancer risk assessments on using electronic portal imaging device (EPID) and cone beam computed tomography (CBCT) as image guided tools for the early lung cancer patients treated with SBRT. METHODS: The imaging doses from MV-EPID and kV-CBCT of the Edge accelerator were retrospectively added to sixty-one SBRT treatment plans of early lung cancer patients. The MV-EPID imaging dose (6MV Photon beam) was calculated in Pinnacle TPS, and the kV-CBCT imaging dose was simulated and calculated by modeling of the kV energy beam in TPS using Pinnacle automatic modeling program. Three types of plans, namely PlanEPID, PlanCBCT and Planorigin, were generated with incorporating doses of EPID, CBCT and no imaging, respectively, for analysis. The effects of imaging doses on dose-volume-histogram (DVH) and plan quality were analyzed, and the excess absolute risk (EAR) of secondary cancer for ipsilateral lung was evaluated. RESULTS: The regions that received less than 50 cGy were significantly impacted by the imaging doses, while the isodose lines greater than 1000 cGy were barely changed. The DVH values of ipsilateral lung increased the most in PlanEPID, followed by PlanCBCT. Compared to Planorigin on the average, the estimated EAR of ipsilateral lung in PlanEPID increased by 3.43%, while the corresponding EAR increase in PlanCBCT was much smaller (about 0.4%). Considering only the contribution of the imaging dose, the EAR values for the ipsilateral lung due to the MV-EPID dose in 5 years,10 years and 15 years were 1.49 cases, 2.09 cases and 2.88 cases per 104PY respectively, and those due to the kV-CBCT dose were about 9 times lower, correspondingly. CONCLUSIONS: The imaging doses produced by MV-EPID and kV-CBCT had little effects on the target dose coverage. The secondary cancer risk caused by MV-EPID dose is more than 8.5 times that of kV-CBCT.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Neoplasias Pulmonares/radioterapia , Neoplasias Induzidas por Radiação/etiologia , Radiocirurgia , Radioterapia Guiada por Imagem/efeitos adversos , Idoso , Carcinoma Pulmonar de Células não Pequenas/patologia , Simulação por Computador , Fracionamento da Dose de Radiação , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Órgãos em Risco , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem/métodos , Medição de Risco
6.
J Vasc Interv Radiol ; 32(4): 562-568, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33558125

RESUMO

PURPOSE: To compare the utility of low-dose versus standard cone-beam computed tomography (CT) angiography protocols in identifying nontarget embolization (NTE) during prostatic artery embolization (PAE). MATERIALS AND METHODS: A prospective, single-center, Phase-1 study (NCT02592473) was conducted for lower urinary tract symptoms in benign prostatic hyperplasia. Prostate volume, international prostate symptom score (IPSS), quality of life score (QoL), International Index of Erectile Function (IIEF), peak flow rate, UCLA Prostate Cancer Index (UCLA-PCI), and postvoid residual were recorded at baseline and 1, 3, 6, 12, and 24-months after PAE. Six-second (standard protocol, n = 29) or 5-second (low-dose protocol n = 45) rotations were made. Images were selected and matched in pairs by areas of NTE and compared by readers using a binomial generalized estimating equation model. Procedural outcomes were analyzed using a linear mixed model. RESULTS: Seventy-four cone-beam CT angiographies were performed in 21 patients. IPSS and QoL scores significantly improved (P <.05). There was no change in UCLA-PCI or IIEF scores. Dose area product of the low- and standard-dose protocol were 37,340.82 mGy·cm2 ± 104.66 and 62,645.66 mGy·cm2 ± 12,711.48, respectively, representing a dose reduction of 40.4%. A total of 120 comparisons showed no preference between the 2 protocols (P =.24). Observers identified 76 and 69 instances of NTE in the standard- and low-dose protocols, respectively (P =.125). CONCLUSIONS: Low-dose cone-beam CT angiography achieved equivalent clinical utility in identifying NTE during PAE, with the advantage of a lower radiation dose.


Assuntos
Artérias/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Tomografia Computadorizada de Feixe Cônico , Embolização Terapêutica , Sintomas do Trato Urinário Inferior/terapia , Próstata/irrigação sanguínea , Hiperplasia Prostática/terapia , Doses de Radiação , Exposição à Radiação/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Embolização Terapêutica/efeitos adversos , Humanos , Sintomas do Trato Urinário Inferior/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Hiperplasia Prostática/diagnóstico por imagem , Exposição à Radiação/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
7.
Int J Radiat Oncol Biol Phys ; 110(2): 412-424, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33316362

RESUMO

PURPOSE: Hypofractionated radiation therapy can be used to treat patients with muscle-invasive bladder cancer unable to have radical therapy. Toxicity is a key concern, but adaptive plan-of the day (POD) image-guided radiation therapy delivery could improve outcomes by minimizing the volume of normal tissue irradiated. The HYBRID trial assessed the multicenter implementation, safety, and efficacy of this strategy. METHODS: HYBRID is a Phase II randomized trial that was conducted at 14 UK hospitals. Patients with T2-T4aN0M0 muscle-invasive bladder cancer unsuitable for radical therapy received 36 Gy in 6 weekly fractions, randomized (1:1) to standard planning (SP) or adaptive planning (AP) using a minimization algorithm. For AP, a pretreatment cone beam computed tomography (CT) was used to select the POD from 3 plans (small, medium, and large). Follow-up included standard cystoscopic, radiologic, and clinical assessments. The primary endpoint was nongenitourinary Common Terminology Criteria for Adverse Events (CTCAE) grade ≥ 3 (≥G3) toxicity within 3 months of radiation therapy. A noncomparative single stage design aimed to exclude ≥30% toxicity rate in each planning group in patients who received ≥1 fraction of radiation therapy. Local control at 3-months (both groups combined) was a key secondary endpoint. RESULTS: Between April 15, 2014, and August 10, 2016, 65 patients were enrolled (SP, n = 32; AP, n = 33). The median follow-up time was 38.8 months (interquartile range [IQR], 36.8-51.3). The median age was 85 years (IQR, 81-89); 68% of participants (44 of 65) were male; and 98% of participants had grade 3 urothelial cancer. In 63 evaluable participants, CTCAE ≥G3 nongenitourinary toxicity rates were 6% (2 of 33; 95% confidence interval [CI], 0.7%-20.2%) for the AP group and 13% (4 of 30; 95% CI, 3.8%-30.7%) for the SP group. Disease was present in 9/48 participants assessed at 3 months, giving a local control rate of 81.3% (95% CI, 67.4%-91.1%). CONCLUSIONS: POD adaptive radiation therapy was successfully implemented across multiple centers. Weekly ultrahypofractionated 36 Gy/6 fraction radiation therapy is safe and provides good local control rates in this older patient population.


Assuntos
Radioterapia Guiada por Imagem , Neoplasias da Bexiga Urinária/radioterapia , Idoso de 80 Anos ou mais , Algoritmos , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estadiamento de Neoplasias , Medidas de Resultados Relatados pelo Paciente , Hipofracionamento da Dose de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/efeitos adversos , Radioterapia Guiada por Imagem/métodos , Fatores de Tempo , Resultado do Tratamento , Reino Unido , Neoplasias da Bexiga Urinária/patologia
8.
J Vasc Interv Radiol ; 32(3): 429-438, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33358328

RESUMO

PURPOSE: To evaluate the radiation dose differences for intraprocedural computed tomography (CT) imaging between cone-beam CT and angio-CT acquired during transarterial radioembolization (TARE) therapies for hepatocellular carcinoma. MATERIALS AND METHODS: A retrospective cohort of 22 patients who underwent 23 TARE procedures were selected. Patients were imaged in both cone-beam CT and angio-CT rooms as a part of their conventional treatment plan. Effective dose contributions from individual CT acquisitions as well as the cumulative dose contributions from procedural 3D imaging were evaluated. Angiography dose contributions were omitted. Cone-beam CT images were acquired on a C-arm Philips Allura system. Effective doses were evaluated by coupling previously published conversion factors (effective dose per dose-area product) to patient's dose-area product meter readings after the procedure. Angio-CT images were acquired on a hybrid Canon Infinix-i Aquilion PRIME system. Effective doses from angio-CT scans were estimated using Radimetrics. Comparisons of a single patient's dose differential between the 2 technologies were made. RESULTS: The mean effective dose from a single CT scan was 6.42 mSv and 5.99 mSv in the cone-beam CT room and the angio-CT room, respectively (P = .3224), despite the greater field of view and average craniocaudal scan coverage in angio-CT. The mean effective dose summed across all CTs in a procedure was 12.89 mSv and 34.35 mSv in the cone-beam CT room and the angio-CT room, respectively (P = .0018). CONCLUSIONS: The mean effective dose per CT scan is comparable between cone-beam CT and angio-CT when considered in direct comparison for a single patient.


Assuntos
Carcinoma Hepatocelular/terapia , Angiografia por Tomografia Computadorizada , Tomografia Computadorizada de Feixe Cônico , Embolização Terapêutica , Neoplasias Hepáticas/terapia , Doses de Radiação , Compostos Radiofarmacêuticos/administração & dosagem , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Angiografia por Tomografia Computadorizada/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Embolização Terapêutica/efeitos adversos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
Strahlenther Onkol ; 197(2): 124-132, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32833036

RESUMO

PURPOSE: Evaluation of long-term outcome and toxicity of moderately hypofractionated radiotherapy using intensity-modulated radiotherapy (IMRT) with simultaneous integrated boost treatment planning and cone beam CT-based image guidance for localized prostate cancer. METHODS: Between 2005 and 2015, 346 consecutive patients with localized prostate cancer received primary radiotherapy using cone beam CT-based image-guided intensity-modulated radiotherapy (IG-IMRT) and volumetric modulated arc therapy (IG-VMAT) with a simultaneous integrated boost (SIB). Total doses of 73.9 Gy (n = 44) and 76.2 Gy (n = 302) to the high-dose PTV were delivered in 32 and 33 fractions, respectively. The low-dose PTV received a dose (D95) of 60.06 Gy in single doses of 1.82 Gy. The pelvic lymph nodes were treated in 91 high-risk patients to 45.5 Gy (D95). RESULTS: Median follow-up was 61.8 months. The 5­year biochemical relapse-free survival (bRFS) was 85.4% for all patients and 93.3, 87.4, and 79.4% for low-, intermediate-, and high-risk disease, respectively. The 5­year prostate cancer-specific survival (PSS) was 94.8% for all patients and 98.7, 98.9, 89.3% for low-, intermediate-, and high-risk disease, respectively. The 5­year and 10-year overall survival rates were 83.8 and 66.3% and the 5­year and 10-year freedom from distant metastasis rates were 92.2 and 88.0%, respectively. Cumulative 5­year late GU toxicity and late GI toxicity grade ≥2 was observed in 26.3 and 12.1% of the patients, respectively. Cumulative 5­year late grade 3 GU/GI toxicity occurred in 4.0/1.2%. CONCLUSION: Moderately hypofractionated radiotherapy using SIB treatment planning and cone beam CT image guidance resulted in high biochemical control and survival with low rates of late toxicity.


Assuntos
Neoplasias da Próstata/radioterapia , Hipofracionamento da Dose de Radiação , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Idoso , Idoso de 80 Anos ou mais , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem , Próstata/efeitos da radiação , Neoplasias da Próstata/diagnóstico por imagem , Radioterapia Guiada por Imagem/efeitos adversos , Radioterapia de Intensidade Modulada/efeitos adversos , Análise de Sobrevida , Resultado do Tratamento
10.
Clin Orthop Relat Res ; 479(1): 151-160, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32701771

RESUMO

BACKGROUND: Cone beam CT (CBCT) is a widely available technique with possible indications in carpal ligament injuries. The accuracy of CBCT arthrography in diagnosing traumatic tears of the scapholunate ligament has not been reported. QUESTIONS/PURPOSES: (1) What is the diagnostic accuracy of CBCT and how does it relate to the accuracy of multislice CT arthrography and conventional arthrography in diagnosing scapholunate ligament tears? (2) What is the estimated magnitude of skin radiation doses of each method? METHODS: This secondary analysis of a previous prospective study included 71 men and women with suspected scapholunate ligament tears and indications for arthroscopy. Preoperative imaging was conventional arthrography and either MSCT arthrography for the first half of patients to be included (n = 36) or flat-panel CBCT arthrography for the remaining patients (n = 35). Index tests identified therapy-relevant SLL tears with dorsal or complete SLL ruptures, and these tears were compared with relevant SLL tears which were determined through arthroscopy as Geissler Stadium III and IV by probing the instable SL joint with a microhook or arthroscope. These injuries were treated by open ligament repair and Kirschner wire fixation. Accuracy values and 95% confidence intervals were calculated. Additional estimates of the radiation skin doses of each CBCT exam and two MSCT protocols were subsequently calculated using dose area products, dose length products, and CT dose indices. RESULTS: The diagnostic accuracy was high for all imaging methods. 95% CIs were broadly overlapping and therefore did not indicate differences between the diagnostic groups: Sensitivity of CBCT arthrography was 100% (95% CI 77 to 100), specificity was 95% (95% CI 76 to 99.9), positive predictive value was 93% (95% CI 68 to 99.8), and negative predictive value was 100% (95% CI 83 to 100). For MSCT arthrography, the sensitivity was 92% (95% CI 64 to 99.8), specificity was 96% (95% CI 78 to 99.9), positive predictive value was 92% (95% CI 64 to 99.8), and negative predictive value was 96% (95% CI 78 to 99.9). For conventional arthrography, the sensitivity was comparably high: 96% (95% CI 81 to 99.9). Specificity was (81% [95% CI 67 to 92]); the positive predictive value was 77% (95% CI 59 to 89) and negative predictive value was 97% (95% CI 86 to 99.9). Estimated mean (range) radiation skin doses were reported in a descriptive fashion and were 12.9 mSv (4.5 to 24.9) for conventional arthrography, and 3.2 mSv (2.0 to 4.8) for CBCT arthrography. Estimated radiation skin doses were 0.2 mSv and 12 mSv for MSCT arthrography, depending on the protocol. CONCLUSION: Flat-panel CBCT arthrography can be recommended as an accurate technique to diagnose scapholunate ligament injuries after wrist trauma. Estimated skin doses are low for CBCT arthrography and adapted MSCT arthrography protocols. LEVEL OF EVIDENCE: Level III, diagnostic study.


Assuntos
Artrografia , Tomografia Computadorizada de Feixe Cônico , Ligamentos Articulares/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Traumatismos do Punho/diagnóstico por imagem , Adulto , Artrografia/efeitos adversos , Artroscopia , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Feminino , Humanos , Ligamentos Articulares/lesões , Ligamentos Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/efeitos adversos , Valor Preditivo dos Testes , Doses de Radiação , Exposição à Radiação/efeitos adversos , Reprodutibilidade dos Testes , Pele/efeitos da radiação , Traumatismos do Punho/cirurgia
11.
J Vasc Interv Radiol ; 30(9): 1452-1458, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31371137

RESUMO

PURPOSE: To evaluate the radiation dose in patients undergoing prostatic artery embolization (PAE) using cone-beam CT and 3-dimensional (3D) guidance software. MATERIALS AND METHODS: In this single-center retrospective study, 100 patients with benign prostatic hyperplasia (mean prostate volume, 83.6 mL ± 44.2; 69.4 ± 9.6 years of age; body mass index, 26.5 ± 4.2) were treated using PAE between October 2016 and April 2018. Informed consent was obtained from all participants included in the study. All patients received at least 1 intraprocedural cone-beam CT per side for evaluation of the vessel anatomy and software rendering of 3D guidance for catheter guidance. Digital subtraction angiography (DSA) was performed in the distal branches only. The total dose area product (DAP), along with the DAP attributed to fluoroscopy, DSA, and cone-beam CT, were assessed. RESULTS: Bilateral embolization was achieved in 83 patients (83%). The average total DAP was 134.4 Gy ⋅ cm2 ± 69.5 (range, 44.7-410.9 Gy ⋅ cm2). Fluoroscopy, DSA, and cone-beam CT accounted for 35.5 Gy ⋅ cm2 ± 21.3 (range, 8.6-148.6 Gy ⋅ cm2) or 26.4% (percentage of total DAP), 58.2 Gy ⋅ cm2 ± 48.3 (range, 10.3-309.3 Gy ⋅ cm2) or 43.3%, and 40.7 Gy ⋅ cm2 ± 14.5 (range, 15.9-86.3 Gy ⋅ cm2) or 30.3%, respectively. Average procedure time was 89.4 ± 27.0 minutes, and the average fluoroscopy time was 30.9 ± 12.2 minutes. CONCLUSIONS: Intraprocedural cone-beam CT in combination with 3D guidance software allows for identification and catheterization of the prostatic artery in PAE. Furthermore, the results of this trial indicate that this study protocol may lead to a low overall radiation dose.


Assuntos
Artérias/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Tomografia Computadorizada de Feixe Cônico , Embolização Terapêutica , Imageamento Tridimensional , Próstata/irrigação sanguínea , Hiperplasia Prostática/terapia , Doses de Radiação , Radiografia Intervencionista/métodos , Software , Idoso , Angiografia por Tomografia Computadorizada/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Embolização Terapêutica/efeitos adversos , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Hiperplasia Prostática/diagnóstico por imagem , Exposição à Radiação , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Tempo
12.
J Vasc Interv Radiol ; 30(8): 1273-1280, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31235410

RESUMO

PURPOSE: To evaluate the performance of C-arm computed tomography (CT)-guided chemoembolization in patients with hepatocellular carcinoma (HCC) with serum α-fetoprotein (AFP) level > 20 ng/mL but with no overt tumor on CT and/or magnetic resonance imaging. MATERIALS AND METHODS: From May 2010 to May 2017, 34 patients with HCC (25 men and 9 women; mean age, 59.7 y) who had elevated serum AFP levels (> 20 ng/mL) but no overt tumor on 6-mo imaging studies and had shown complete response (CR) after previous chemoembolization underwent C-arm CT-guided conventional chemoembolization. Three radiologists retrospectively reviewed the imaging studies (preprocedural images, C-arm CT scans, and follow-up images) in consensus, and clinical data including AFP levels were retrospectively obtained. Tumor detection by C-arm CT and treatment response after chemoembolization were assessed. RESULTS: HCC was imaged at the time of chemoembolization in 24 of 34 patients (70.6%). C-arm CT detected tumors in 25 patients (73.5%); 23 detections were true positives, 2 were false positives, and 1 was a false negative (diaphragm metastasis). Among the 23 patients with true-positive results, the first follow-up enhanced imaging studies showed CR (n = 17), partial response (n = 1), progressive disease (n = 4), and indeterminate status (n = 1; treated by percutaneous ethanol injection). CONCLUSIONS: C-arm CT-guided chemoembolization may help to detect and treat recurrent tumors in patients who have shown CR after previous chemoembolization but subsequently, during follow-up surveillance, had serum AFP levels > 20 ng/mL without an overt tumor evident on imaging studies.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica , Tomografia Computadorizada de Feixe Cônico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Radiografia Intervencionista/métodos , alfa-Fetoproteínas/metabolismo , Adulto , Idoso , Carcinoma Hepatocelular/sangue , Quimioembolização Terapêutica/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Humanos , Neoplasias Hepáticas/sangue , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Radiografia Intervencionista/efeitos adversos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Regulação para Cima
13.
Oncology ; 96(4): 173-178, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30836369

RESUMO

Firstly used in the early 90s to generate 3-dimensional projections of X-ray images, cone beam computed tomography (CBCT) has resulted in a large application in dentomaxillofacial imaging, even in children. CBCT uses ionizing radiation that may cause damage to the DNA, and children are at the greatest carcinogenesis risk due to their higher tissue radiosensitivity and their longer life expectancy compared to adults. The questions of whether the cancer risk is really increased after repeated dental CBCT in childhood and of what the underlying biological basis is have become hot topics in the field of dentistry and radiobiology. We performed an overview of the current literature to assess an acceptable role of CBCT in pediatric dentistry.


Assuntos
Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Dano ao DNA , Neoplasias Induzidas por Radiação/etiologia , Odontopediatria , Exposição à Radiação/efeitos adversos , Radiografia Dentária/efeitos adversos , Fatores Etários , Humanos , Neoplasias Induzidas por Radiação/diagnóstico , Neoplasias Induzidas por Radiação/genética , Odontopediatria/métodos , Radiografia Dentária/métodos , Medição de Risco , Fatores de Risco , Fatores de Tempo
14.
J Vasc Interv Radiol ; 30(3): 390-395, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30819481

RESUMO

PURPOSE: To assess the safety and efficacy of single-session transarterial embolization and radiofrequency (RF) ablation for hepatic tumors with the use of needle navigation software. MATERIALS AND METHODS: Retrospective analysis was conducted of 24 patients with liver cancer undergoing embolization followed by RF ablation between May 2014 and August 2017. Twelve patients each underwent (i) embolization and computed tomography (CT)-guided RF ablation during different sessions (group 1) and (ii) embolization followed by RF ablation with cone-beam CT and Needle Assist software in 1 session (group 2). Median age (70.5 y [range, 58-78 y] vs 70.5 y [range, 50-82 y]; P = .76) and performance status (0/1) were comparable between groups. Median tumor size was significantly larger in group 2 (2 cm [range, 1.0-7.3 cm] vs 3.2 cm [range, 1.1-9.6 cm]; P < .03). Procedure time, effective dose, and number of scans were examined. Efficacy was assessed by modified Response Evaluation Criteria In Solid Tumors after 1 month. Safety was assessed by Society of Interventional Radiology adverse event classification. RESULTS: Group 1 had a mean of 8.5 CT scans, vs a mean of 5.0 cone-beam CT scans in group 2 (P < .001). Median procedure times were 110 min in group 1 and 199.5 min in group 2 (P < .001). Median effective doses were 68.8 mSv in group 1 and 55.4 mSv in group 2 (P = .38). There was no difference in complete response between groups (66.7% vs 63.6%; P = 1). CONCLUSIONS: Transarterial embolization followed by RF ablation with cone-beam CT and needle guidance software in a single session seems to be safe and effective.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Embolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Ablação por Radiofrequência/métodos , Radiografia Intervencionista/métodos , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/instrumentação , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Agulhas , Doses de Radiação , Exposição à Radiação , Ablação por Radiofrequência/efeitos adversos , Ablação por Radiofrequência/instrumentação , Radiografia Intervencionista/efeitos adversos , Critérios de Avaliação de Resposta em Tumores Sólidos , Estudos Retrospectivos , Software , Fatores de Tempo , Resultado do Tratamento , Carga Tumoral
15.
Neurosurg Rev ; 42(2): 417-426, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29663092

RESUMO

Although spinal instrumentation technique has undergone revolutionary progress over the past few decades, it may still carry significant surgery-related risks. The purpose of the present study was to assess the radiological accuracy of spinal screw instrumentation using a hybrid operating room (OR) and quantify the related radiation exposure. This retrospective study included 33 cases of complex spine fusion surgeries that were conducted using a hybrid OR with a flat panel detector (FPD) angiography system. Twelve cases (36.4%) were cervical, and 21 (63.6%) were thoracolumbar. The average number of spine fusion levels was 3 and 4.8, respectively, at the cervical and thoracolumbar spine levels. A FPD angiography system was used for intraoperative cone-beam computed tomography (CBCT) to obtain multi-slice spine images. All operations were conducted under optimized radiation shielding. Entrance surface doses (ESDs) and exposure times were recorded in all cases. A total of 313 screws were placed. Satisfactory screw insertion could be achieved in all cases with safe screw placement in 97.4% and acceptable placement in 2.6%. None of the cases showed any significant anatomical violation by the screws. The radiation exposure to the patients was absolutely consistent with the desired ESD value, and that to the surgeons, under the annual dose limit. These results suggest that the hybrid OR with a FPD angiography system is helpful to achieve safe and precise spinal fusion surgery, especially in complex cases.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Doenças da Coluna Vertebral/cirurgia , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Coluna Vertebral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Parafusos Ósseos , Angiografia por Tomografia Computadorizada/instrumentação , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Feminino , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Salas Cirúrgicas/classificação , Exposição à Radiação , Estudos Retrospectivos , Fusão Vertebral/efeitos adversos , Resultado do Tratamento , Adulto Jovem
16.
Dentomaxillofac Radiol ; 48(1): 20170462, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30168750

RESUMO

OBJECTIVES: Cone-beam CT (CBCT), a radiographic tool for diagnosis, treatment, and follow-up in dental practice, was introduced also in pediatric radiology, especially orthodontics. Such patients subjected to repetitive X-rays examinations may receive substantial levels of radiation doses. Ionizing radiation (IR), a recognized carcinogenic factor causing DNA double-strand breaks (DSBs) could be harmful to undifferentiated cells such as dental pulp stem cells (DPSCs) since inaccurately repaired or unrepaired DSBs may lead to malignant transformation. The H2AX and MRE11 proteins generated following DSBs formation and pro-inflammatory cytokines (CKs) secreted after irradiation are relevant candidates to monitor the cellular responses induced by CBCT. METHODS: DPSCs were extracted from human exfoliated deciduous teeth and their phenotype was assessed by immunocytochemistry and flow-cytometry. Cells were exposed to IR doses: 5.4-107.7 mGy, corresponding to 0.5-8 consecutive skull exposures, respectively. H2AX and MRE11 were detected in whole cells, while IL-1α, IL-6, IL-8, TNFα in supernatants, using enzyme-linked immunosorbent assay (ELISA) at different time points after exposure. RESULTS: The phosphorylation level of H2AX in DPSCs increased considerably at 0.5 h after exposure (p < 0.001 for 3, 5, 8 skull exposures and p < 0.05 for 1 skull exposure, respectively). MRE11 response could only be detected for the highest IR dose (p < 0.001) in the same interval. CKs secretion increased upon CBCT exposure according to doses and time. CONCLUSIONS: The DPSCs exposure to CBCT induces transient DNA damage and persistent inflammatory reaction in DPSCs drawing the attention on the potential risks of IR exposures and on the importance of dose monitoring in pediatric population.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Dano ao DNA , Células-Tronco , Dente Decíduo , Criança , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Humanos , Inflamação , Fosforilação , Células-Tronco/efeitos da radiação
17.
Radiat Environ Biophys ; 58(1): 21-37, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30392077

RESUMO

Cone-beam computed tomography (CBCT) is widely used for pre-treatment verification and patient setup in image-guided radiation therapy (IGRT). CBCT imaging is employed daily and several times per patient, resulting in potentially high cumulative imaging doses to healthy tissues that surround exposed target organs. Computed tomography dose index (CTDI) is the parameter used by CBCT equipment as indication of the radiation output to patients. This study aimed to increase the knowledge on the relation between CBCT organ doses and weighted CTDI (CTDIW) for a thorax scanning protocol. A CBCT system was modelled using the Monte Carlo (MC) radiation transport program MCNPX2.7.0. Simulation results were validated against half-value layer (HVL), axial beam profile, patient skin dose (PSD) and CTDI measurements. For organ dose calculations, a male voxel phantom ("Golem") was implemented with the CBCT scanner computational model. After a successful MC model validation with measurements, a systematic comparison was performed between organ doses (and their distribution) and CTDI dosimetry concepts [CTDIW and cumulative dose quantities f100(150) and [Formula: see text]]. The results obtained show that CBCT organ doses vary between 1.2 ± 0.1 mGy and 3.3 ± 0.2 mGy for organs located within the primary beam. It was also verified that CTDIW allows prediction of absorbed doses to tissues at distances of about 5 cm from the isocentre of the CBCT system, whereas f100(150) allows prediction of organ doses at distances of about 10 cm from the isocentre, independently from its location. This study demonstrates that these dosimetric concepts are suitable methods that easily allow a good approximation of the additional CBCT imaging doses during a typical lung cancer IGRT treatment.


Assuntos
Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Exposição à Radiação/efeitos adversos , Humanos , Masculino , Método de Monte Carlo , Aceleradores de Partículas , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Radioterapia Guiada por Imagem/instrumentação , Tórax/diagnóstico por imagem , Tórax/efeitos da radiação
18.
J Vasc Surg ; 69(4): 1045-1058.e3, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30527938

RESUMO

OBJECTIVE: The objective of this study was to analyze the impact of advanced imaging applications and cone beam computed tomography (CBCT) on radiation exposure of the patient and operator and detection of technical problems during fenestrated-branched endovascular aortic repair (F-BEVAR) for treatment of pararenal aneurysms and thoracoabdominal aortic aneurysms (TAAAs). METHODS: We reviewed the clinical data of 386 consecutives patients (289 male; mean age, 75 ± 8 years) treated by F-BEVAR for 196 pararenal aneurysms and 190 TAAAs (mean, 3.4 ± 0.9 targeted vessels/patient) between 2007 and 2017. Radiation exposure (cumulative air kerma) was analyzed in three fixed imaging systems used between 2007 and 2011 (system 1), 2012 and 2016 (system 2), and 2016 and 2017 (system 3). Onlay fusion and CBCT were available with systems 2 and 3, whereas digital zoom with fusion overlay was used with system 3. Operator effective dose was measured per month using a radiation dosimeter badge. Computed tomography angiography and CBCT were analyzed for findings requiring immediate revision or secondary interventions. End points were patient radiation exposure; operator effective dose; procedure technical success; and 30-day rates of mortality, major adverse events, and secondary interventions. RESULTS: F-BEVAR was performed using system 1 in 98 patients, system 2 in 198 patients, and system 3 in 90 patients. Use of onlay fusion/CBCT was 0% with system 1, 42% with system 2, and 98% with system 3. Procedures performed with onlay fusion/CBCT had significantly (P < .05) higher technical success (99.4% vs 98.8%) and lower contrast material volume (155 ± 58 mL vs 172 ± 80 mL), fluoroscopy time (83 ± 34 minutes vs 94 ± 49 minutes), and cumulative air kerma (2561 ± 1920 mGy vs 3767 ± 2307 mGy). Despite higher case volume and increasing complexity during the experience, operator effective dose decreased to 9 ± 4 × 10-2 mSv/case with system 3 compared with 26 ± 3 × 10-2 mSv/case with system 1 and 20 ± 2 × 10-2 mSv/case with system 2 (P = .001). Among 219 patients who had no CBCT, 18 (8%) had computed tomography angiography findings that prompted secondary interventions before dismissal. Conversely, among 167 patients who had CBCT, 14 patients (8%) had intraoperative CBCT findings requiring immediate revision, with no additional secondary interventions. Patients treated with onlay fusion/CBCT had significantly (P < .05) lower mortality (4% vs 1%), major adverse events (43% vs 19%), and secondary interventions (10% vs 4%) at 30 days. CONCLUSIONS: Radiation exposure and operator effective dose significantly decreased with evolution of F-BEVAR experience and use of advanced imaging applications such as onlay fusion and CBCT. CBCT allowed immediate assessment and identified intraoperative technical problems, leading to immediate revision and avoiding early secondary interventions.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Aortografia/métodos , Implante de Prótese Vascular , Angiografia por Tomografia Computadorizada , Tomografia Computadorizada de Feixe Cônico , Procedimentos Endovasculares , Exposição Ocupacional/prevenção & controle , Exposição à Radiação/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/efeitos adversos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Exposição Ocupacional/efeitos adversos , Valor Preditivo dos Testes , Desenho de Prótese , Doses de Radiação , Exposição à Radiação/efeitos adversos , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Stents , Resultado do Tratamento
19.
J Vasc Interv Radiol ; 30(1): 10-18, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30580809

RESUMO

PURPOSE: To evaluate the outcomes of conventional transarterial chemoembolization using guidance software for hepatocellular carcinoma (HCC) patients. MATERIALS AND METHODS: One hundred two patients with treatment-naïve HCC with ≤ 7-cm and ≤ 5 lesions treated with conventional transarterial chemoembolization using guidance software were selected. Technical success was classified into 3 grades by computed tomography performed 1 week after transarterial chemoembolization: (i) A, complete embolization with a safety margin; (ii) B, entire tumor embolization without a safety margin; and (iii) C, incomplete embolization. Intrahepatic tumor recurrence was classified into 2 categories: local tumor progression (LTP) and intrahepatic distant recurrence (IDR). Overall survival (OS) and tumor recurrence rates were calculated by the Kaplan-Meier method. Additionally, the incidences of LTP between grade A and B tumors, IDR with/without LTP, and OS with/without LTP were compared by the log-rank test. RESULTS: One hundred fifty-six (82.1%) tumors were determined to be grade A, 26 (13.7%) were determined to be grade B, and 8 (4.2%) were determined to be grade C. The 1-, 3-, and 5-year LTP and IDR rates were 31.7%, 49.4%, and 59.4% and 33.9%, 58.2%, and 73.3%, respectively. LTP developed more frequently in grade B tumors than grade A tumors (P = .0016). IDR developed more frequently in patients with LTP than without LTP (P = .0004). The 1-, 3-, and 5-year OS rates were 96.1%, 71.1%, and 60%, respectively; the 1-, 3-, and 5-year OS rates in patients with/without LTP were 95.7%, 69.8%, and 59.3% and 96.2%, 71.6%, and 59.4%, respectively (P = .9984). CONCLUSIONS: Transarterial chemoembolization guidance software promotes the technical success of transarterial chemoembolization and excellent OS in HCC patients.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Hepáticas/terapia , Radiografia Intervencionista/métodos , Software , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/secundário , Quimioembolização Terapêutica/efeitos adversos , Quimioembolização Terapêutica/mortalidade , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/mortalidade , Progressão da Doença , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Recidiva Local de Neoplasia , Valor Preditivo dos Testes , Radiografia Intervencionista/efeitos adversos , Radiografia Intervencionista/mortalidade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
20.
Radiat Oncol ; 13(1): 168, 2018 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-30185206

RESUMO

BACKGROUND: Daily image-guided radiotherapy (IGRT) can contribute to cover extended body volumes with low radiation dose. The effect of additional imaging dose on secondary cancer development is modelled for a collective of children with Morbus Hodgkin. METHODS: Eleven radiotherapy treatment plans from pediatric patients with Hodgkin's lymphoma were retrospectively analyzed, including imaging dose from scenarios using different energies (kV/MV) and planar/cone-beam computed tomography (CBCT) techniques. In addition to assessing the effect of imaging dose on organs at risk, the excess average risk (EAR) for developing a secondary carcinoma of the lung or breast was modelled. RESULTS: Although the variability between the patients is relatively large due to the different target volumes, the additional EAR due to imaging can be consistently determined. For daily 6MV CBCT, the EAR for developing a secondary cancer at age 50 is over 3 cases per 104 PY (patient-years) for the female breast and 0.7-0.8 per 104 PY for the lungs. This can be decreased by using only planar images (< 1 per 104 PY for the breast and 0.1 for the lungs). Similar values are achieved by daily 360° kV CBCT (0.44-0.57 per 104 PY for the breast and 0.08 per 104 PY for the lungs), which is again reduced for daily 200° kV CBCT (0.02 per 104 PY for the lungs and 0.07-0.08 per 104 PY for the breast). These values increase if an older attained age is considered (e.g., for 70 years, by a factor of four for the lungs). CONCLUSIONS: Daily imaging can be performed with an additional secondary cancer risk of less than 1 per 104 PY if kV CBCT is applied. If MV modalities must be chosen, a similar EAR can be achieved with planar images. A further reduction in risk is possible if the imaging geometry allows for sparing of the breast by a partial rotation underneath the patient.


Assuntos
Doença de Hodgkin/radioterapia , Neoplasias Induzidas por Radiação/etiologia , Segunda Neoplasia Primária/etiologia , Exposição à Radiação/efeitos adversos , Radioterapia Guiada por Imagem/efeitos adversos , Adolescente , Criança , Pré-Escolar , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Feminino , Alemanha , Humanos , Masculino , Imagens de Fantasmas , Doses de Radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/efeitos adversos , Estudos Retrospectivos , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA