Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.301
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Int J Oral Sci ; 16(1): 34, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719817

RESUMO

Accurate segmentation of oral surgery-related tissues from cone beam computed tomography (CBCT) images can significantly accelerate treatment planning and improve surgical accuracy. In this paper, we propose a fully automated tissue segmentation system for dental implant surgery. Specifically, we propose an image preprocessing method based on data distribution histograms, which can adaptively process CBCT images with different parameters. Based on this, we use the bone segmentation network to obtain the segmentation results of alveolar bone, teeth, and maxillary sinus. We use the tooth and mandibular regions as the ROI regions of tooth segmentation and mandibular nerve tube segmentation to achieve the corresponding tasks. The tooth segmentation results can obtain the order information of the dentition. The corresponding experimental results show that our method can achieve higher segmentation accuracy and efficiency compared to existing methods. Its average Dice scores on the tooth, alveolar bone, maxillary sinus, and mandibular canal segmentation tasks were 96.5%, 95.4%, 93.6%, and 94.8%, respectively. These results demonstrate that it can accelerate the development of digital dentistry.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Processo Alveolar/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Inteligência Artificial , Seio Maxilar/diagnóstico por imagem , Seio Maxilar/cirurgia , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Dente/diagnóstico por imagem
2.
Head Face Med ; 20(1): 33, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760840

RESUMO

BACKGROUND: Dental cone beam computed tomography (CBCT) is commonly used to evaluate cancellous bone density before dental implant surgery. However, to our knowledge, no measurement approach has been standardized yet. This study aimed to evaluate the relationship between three different regions of interest (ROI) methods on cancellous bone density at the dental implant site using dental CBCT images. METHODS: Patients' dental CBCT images (n = 300) obtained before dental implant surgery were processed using Mimics (Materialise, Leuven, Belgium). At the potential implant sites, the rectangle, cylinder, and surrounding cylinder ROI methods were used to measure bone density. Repeated measures one-way analysis of variance was performed to compare the three ROI methods in terms of measurement results. Pearson correlation analysis was performed to identify the likely pair-wise correlations between the three ROI methods. RESULTS: The density value obtained using the surrounding cylinder approach (grayscale value [GV],523.56 ± 228.03) was significantly higher than the values obtained using the rectangle (GV, 497.04 ± 236.69) and cylinder (GV,493 ± 231.19) ROI methods in terms of results. Furthermore, significant correlations were noted between the ROI methods (r > 0.965; p < 0.001). CONCLUSIONS: The density measured using the surrounding cylinder method was the highest. The choice of method may not influence the trends of measurement results. TRIAL REGISTRATION: This study was approved by the Institutional Review Board of China Medical University Hospital, No. CMUH111-REC3-205. Informed consent was waived by the Institutional Review Board of China Medical University Hospital, CMUH111-REC3-205, owing to the retrospective nature of the study.


Assuntos
Densidade Óssea , Tomografia Computadorizada de Feixe Cônico , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Idoso , Estudos Retrospectivos , Cuidados Pré-Operatórios/métodos , Implantação Dentária/métodos , Adulto Jovem , Implantes Dentários , Implantação Dentária Endóssea/métodos
3.
Sci Rep ; 14(1): 11455, 2024 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769329

RESUMO

Cone-beam computed tomography (CBCT) is a crucial component of adaptive radiation therapy; however, it frequently encounters challenges such as artifacts and noise, significantly constraining its clinical utility. While CycleGAN is a widely employed method for CT image synthesis, it has notable limitations regarding the inadequate capture of global features. To tackle these challenges, we introduce a refined unsupervised learning model called improved vision transformer CycleGAN (IViT-CycleGAN). Firstly, we integrate a U-net framework that builds upon ViT. Next, we augment the feed-forward neural network by incorporating deep convolutional networks. Lastly, we enhance the stability of the model training process by introducing gradient penalty and integrating an additional loss term into the generator loss. The experiment demonstrates from multiple perspectives that our model-generated synthesizing CT(sCT) has significant advantages compared to other unsupervised learning models, thereby validating the clinical applicability and robustness of our model. In future clinical practice, our model has the potential to assist clinical practitioners in formulating precise radiotherapy plans.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Redes Neurais de Computação , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Aprendizado de Máquina não Supervisionado
4.
Sci Rep ; 14(1): 11554, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773238

RESUMO

This study aims to determine whether and how the data of the medial sigmoid depression (MSD) area via cone beam computed tomography (CBCT) differs from panoramic radiography. This study also aims to evaluate various sigmoid notch types and assess the relationship between sigmoid depression and notch morphology. A total of 129 individuals consisting of 258 sides were evaluated. Chi-Square/Fisher Exact tests were used to assess parameters on a categorical scale between two or more groups. McNemar's test compared the findings detected on panoramic and CBCT images. MSD was more prevalent in females than males in both techniques, but this difference was not statistically significant. There was no association between the prevalence of MSD and the morphology of the sigmoid notch. The incidence of MSD shape was not significantly different between both imaging modalities. In both panoramic and CBCT, we found a high and similar prevalence of MSD. While the MSD prevalence was 66.7% for CBCT, it was 58.1% for panoramic. The shape or prevalence of MSDs in either approach did not correlate with sigmoid notch morphology. The two approaches' identical prevalence indicates that the panoramic image has adequately defines MSD. The high prevalence of MSD demonstrated how important it is for clinicians to characterize this anatomical variation accurately for the surgical treatment.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radiografia Panorâmica , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Prevalência , Idoso , Adulto Jovem
5.
Gulf J Oncolog ; 1(45): 94-99, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38774938

RESUMO

PURPOSE: We report the use of online adaptive radiotherapy (OART) aiming to improve dosimetric parameters in the prostate cancer patient who had lower urinary tract symptoms that caused him not to adhere to the standard bladder filling protocol. METHODS AND MATERIALS: The reference treatment plan for adaptive radiotherapy plan was generated for the pelvis and the solitary bony lesion using the Ethos treatment planning system. For each treatment session, high-quality iterative reconstructed cone beam CT (CBCT) images were acquired, and the system automatically generated an optimal adaptive plan after verification of contours. Image-guided RT (IGRT) plans were also created using the reference plan recalculated on the CBCT scan and were compared with adaptive plans. RESULTS: The reference bladder volume in the planning CT scan was 173 cc, and the mean bladder volume difference over the course was 25.4% ± 16.6%. The ART offered superior target coverage for PTV 70 Gy over online IGRT (V95: 90.5 ± 3.2 % Vs 97.3 ± 0.4%; p=0.000) and the bladder was also better spared from the high dose (V65 Gy: 17.9 ± 9.1% vs 14.8 ± 3.6%; p=0.03). However, the mean rectum V65 doses were very similar in both plans. CONCLUSION: Managing the inconsistent bladder volume was feasible in the prostate cancer patient using the CBCT-guided OART and our analysis confirmed that adaptive plans offered better target coverage while sparing the bladder from high radiation doses in comparison to online IGRT plans. KEY WORDS: radiotherapy, CBCT, online adaptive radiotherapy, image-guided RT.


Assuntos
Neoplasias da Próstata , Planejamento da Radioterapia Assistida por Computador , Bexiga Urinária , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Bexiga Urinária/patologia , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Idoso
6.
Clin Oral Investig ; 28(6): 331, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38775989

RESUMO

OBJECTIVE: Segmental Le Fort I osteotomy through the cleft is a common strategy to narrow the alveolar cleft in adults. This study compared skeletal stability between single and segmental Le Fort I osteotomies in patients with unilateral cleft lip and palate (UCLP). MATERIALS AND METHODS: This retrospective analysis examined 45 adults with complete UCLP-associated class III deformities who underwent bimaxillary surgery with either single (n = 30) or segmental (n = 15) Le Fort I advancement. Cone beam computed tomography (CBCT) scans of the facial skeleton were acquired before surgery, 1-week postsurgery, and at follow-up. Measures of landmarks from the CBCT images for the two treatment groups were compared for translation (left/right, posterior/anterior, superior/inferior) and rotation (yaw, roll, pitch). RESULTS: Postsurgery, the downward movement of the maxilla was larger in the segmental group than the single group. At follow-up, the maxilla moved backward in both groups, and upward in the segmental group. The mandible moved forward and upward and rotated upward in both groups. The amount of upward movement and rotation was larger in the segmental group than the single group. CONCLUSIONS: Two years after bimaxillary surgery in patients with UCLP-associated class III deformity, greater relapse was found after segmental Le Fort I osteotomies in vertical translation of the maxilla and mandible, and pitch rotation of the mandible compared with single Le Fort I osteotomies. CLINICAL RELEVANCE: The vertical relapse of the maxilla was larger after segmental Le Fort I advancement compared with single Le Fort I advancement in clefts.


Assuntos
Fenda Labial , Fissura Palatina , Tomografia Computadorizada de Feixe Cônico , Má Oclusão Classe III de Angle , Osteotomia de Le Fort , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Fissura Palatina/cirurgia , Fissura Palatina/diagnóstico por imagem , Fenda Labial/cirurgia , Fenda Labial/diagnóstico por imagem , Estudos Retrospectivos , Osteotomia de Le Fort/métodos , Feminino , Masculino , Má Oclusão Classe III de Angle/cirurgia , Má Oclusão Classe III de Angle/diagnóstico por imagem , Adulto , Resultado do Tratamento , Maxila/cirurgia , Maxila/diagnóstico por imagem , Maxila/anormalidades , Osteotomia Maxilar/métodos , Pontos de Referência Anatômicos , Adolescente
7.
Head Face Med ; 20(1): 30, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38745297

RESUMO

BACKGROUND: Computer-guided implant surgery has improved the quality of implant treatment by facilitating the placement of implants in a more accurate manner. This study aimed to assess the accuracy of implant placement in a clinical setting using three techniques: dynamic navigation, static surgical guides, and freehand placement. We also investigated potential factors influencing accuracy to provide a comprehensive evaluation of each technique's advantages and disadvantages. MATERIALS AND METHODS: Ninety-four implants in 65 patients were included in this prospective study. Patients were randomly assigned to one of three groups: dynamic navigation, static surgical guides, or freehand placement. Implants were placed using a prosthetically oriented digital implant planning approach, and postoperative CBCT scans were superimposed on preoperative plans to measure accuracy. Seven deviation values were calculated, including angular, platform, and apical deviations. Demographic and consistency analyses were performed, along with one-way ANOVA and post-hoc tests for deviation values. RESULTS: The mean global platform, global apical, and angular deviations were 0.99 mm (SD 0.52), 1.14 mm (SD 0.56), and 3.66° (SD 1.64°) for the dynamic navigation group; 0.92 mm (SD 0.36), 1.06 mm (SD 0.47), and 2.52° (SD 1.18°) for the surgical guide group; and 1.36 mm (SD 0.62), 1.73 mm (SD 0.66), and 5.82° (SD 2.79°) for the freehand group. Both the dynamic navigation and surgical guide groups exhibited statistically significant differences in all values except depth deviations compared to the freehand group (p < 0.05), whereas only the angular deviation showed a significant difference between the dynamic navigation and surgical guide groups (p = 0.002). CONCLUSION: Our findings highlight the superior accuracy and consistency of dynamic navigation and static surgical guides compared to freehand placement in implant surgery. Dynamic navigation offers precision and flexibility. However, it comes with cost and convenience considerations. Future research should focus on improving its practicality. TRIAL REGISTRATION: This study was retrospectively registered at the Thai Clinical Trials Register-Medical Research Foundation of Thailand (MRF) with the TCTR identification number TCTR20230804001 on 04/08/2023. It was also conducted in accordance with the Declaration of Helsinki and approved by the institutional ethics committee at the Xian Jiaotong University Hospital of Stomatology, Xian, China (xjkqII[2021] No: 043). Written informed consent was obtained from all participants.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Cirurgia Assistida por Computador , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada de Feixe Cônico/métodos , Implantação Dentária Endóssea/métodos , Estudos Prospectivos , Cirurgia Assistida por Computador/métodos
8.
Clin Oral Investig ; 28(6): 310, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38743355

RESUMO

OBJECTIVES: This systematic review and meta-analysis aimed to evaluate the prevalence of middle mesial canal (MMC) in permanent mandibular molars of different populations and regions based on cone-beam computed tomography (CBCT) studies. MATERIALS AND METHODS: PubMed, Scopus, Embase, Web of Science, and Open-Grey were searched up to October 2023 according to specific keywords. A hand search was conducted on the references of the included studies and articles from three peer-reviewed journals in endodontics. The main variable of interest was the prevalence of MMC. Additional data such as the total number of included cases, age and country of the population, CBCT device information, voxel size, and field of view details were also extracted. Extracted data were analyzed qualitatively with the JBI quality assessment checklist and quantitatively with STATA software. RESULTS: Of 32,793 studied teeth, the cumulative prevalence of MMC in both mandibular 1st and 2nd molars was 3.11% (95% CI: 2.00-4.44%). The subgroup analysis reveals a prevalence of 4.15% (95% CI: 2.69-5.89%) for mandibular 1st molars and 1.2% (95% CI: 0.2-2.83%) for mandibular 2nd molars. The highest prevalence of MMC in 1st molar was attributed to South Asia (11.24%) and Africa (6.61%). CONCLUSIONS: The prevalence of MMC varies among regions. Clinicians should be aware of the potential prevalence of MMC, particularly in mandibular first molars, as a missed MMC could result in endodontic failure. CLINICAL RELEVANCE: The presence of MMCs varies in different geographic regions (0% to 29.7%). Clinicians should always look for MMC when doing an endodontic treatment on mandibular molars, as the presence of this canal is not uncommon. We suggest searching for this canal as if searching for the second mesiobuccal canal of maxillary 1st molars.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Cavidade Pulpar , Mandíbula , Dente Molar , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Mandíbula/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Prevalência , Cavidade Pulpar/diagnóstico por imagem , Saúde Global
9.
PLoS One ; 19(5): e0302810, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38713685

RESUMO

OBJECTIVE: The two commonly used diagnostic methods for taurodontism are susceptible to aging changes, mastication wear and other factors. Therefore, this study proposed an improved diagnostic method for taurodontism, and compared it with the previous two methods as a supplement for taurodontism diagnosis. METHODS: The included patients were aged 10-89 years and admitted to the Department of Stomatology of Hebei Eye Hospital from June 1, 2022 to May 31, 2023. Eighty cone-beam computed tomography images were divided equally into 4 groups: 10-29, 30-49, 50-69, and 70-89 years old. The right mandibular first molars were selected as measurement objects. Firstly, |BD| and taurodontism index (TI)-related parameters were measured using Shifman and Chanannel's method and crown-body(CB) and root (R) lengths was measured by Seow and Lai's method. The improved method used the length from the cementoenamel junction(CEJ) to the root bifurcation point(body, B)and the root length(root, R)as the measurement objects. Finally, TI, CB/R ratios, and B/R ratios were calculated according to the formulas given below. One-way ANOVA analysis was mainly used to compare the differences in the values, indices and ratios of taurodontism among different age groups (p<0.05). RESULTS: With the increase of age, |BD| and TI values decreased significantly (p<0.01). The CB/R ratios of 70-89 years group were significantly lower than those of the other three groups (p<0.01). Ratios derived from the improved method were significantly lower in the 70-89 years than in 10-29 years group (p<0.05). CONCLUSIONS: The |BD| and TI parameters proposed by Shifman and channel are significantly influenced by age. The measurements of Seow and Lai (CB/R ratios) were less affected by age compared with those of the former. The improved method(B/R ratios) was least affected by age, which would reduce error and bias in the measurement of taurodontism and obtain more objective results in older patients.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Cavidade Pulpar/anormalidades , Humanos , Idoso , Pessoa de Meia-Idade , Adolescente , Adulto , Idoso de 80 Anos ou mais , Criança , Feminino , Masculino , Adulto Jovem , Tomografia Computadorizada de Feixe Cônico/métodos , Dente Molar/diagnóstico por imagem , Anormalidades Dentárias/diagnóstico por imagem , Anormalidades Dentárias/diagnóstico , Doenças Genéticas Ligadas ao Cromossomo X/diagnóstico
10.
Int J Esthet Dent ; 19(2): 170-185, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726858

RESUMO

Single tooth orange discoloration secondary to root canal calcification occurs as a consequence of dental trauma, orthodontic treatment, or for unknown rea- sons. A correct case history must be compiled and a CBCT study carried out in order to establish the diag- nosis and define the best treatment plan in each case. The aim of the present study was to offer a therapeutic protocol involving a clinical decision-making tree dia- gram based on the presence or absence of apical dis- ease and the degree of canal calcification. Dental bleaching and the use of ceramic veneers allow es- thetic restoration in such cases.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Clareamento Dental , Descoloração de Dente , Humanos , Descoloração de Dente/etiologia , Descoloração de Dente/terapia , Tomografia Computadorizada de Feixe Cônico/métodos , Clareamento Dental/métodos , Facetas Dentárias , Calcificações da Polpa Dentária/diagnóstico por imagem , Calcificações da Polpa Dentária/etiologia , Masculino , Feminino
11.
BMC Oral Health ; 24(1): 408, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561756

RESUMO

BACKGROUND: Supracrestal gingival tissue dimensions (SGTDs) has been considered to be an essential element of periodontal phenotype (PP) components. This study aimed to explore the relationship between SGTDs and other PP components by digital superposition method that integrated cone beam computed tomography (CBCT) with intraoral scanning. METHODS: This cross-sectional study was conducted at the Stomatology Hospital of Fujian Medical University. Participants were recruited based on the inclusion and exclusion criteria. The data obtained from the digital scanner (TRIOS 3, 3Shape, Denmark) and CBCT images were imported into the TRIOS software (Implant Studio, 3Shape, Denmark) for computing relevant parameters. The significant level was set at 0.05. RESULTS: A total of 83 participants with 498 maxillary anterior teeth were finally included. The mean values of supracrestal gingival height (SGH) and the distance from the cementoenamel junction (CEJ) to the crest of the alveolar ridge (CEJ-ABC) on the buccal site were significantly higher than palatal SGH (SGH-p) and palatal CEJ-ABC (CEJ-ABC-p). Men exhibited taller CEJ-ABC and SGH-p than women. Additionally, tooth type was significantly associated with the SGH, SGH-p and CEJ-ABC-p. Taller SGH was associated with wider crown, smaller papilla height (PH), flatter gingival margin, thicker bone thickness (BT) and gingival thickness (GT) at CEJ, the alveolar bone crest (ABC), and 2 mm apical to the ABC. Smaller SGH-p displayed thicker BT and GT at CEJ, the ABC, and 2 and 4 mm apical to the ABC. Higher CEJ-ABC showed lower interproximal bone height, smaller PH, flatter gingival margin, thinner GT and BT at CEJ, and 2 mm apical to the ABC. Smaller CEJ-ABC-p displayed thicker BT at CEJ and 2 and 4 mm apical to the ABC. On the buccal, thicker GT was correlated with thicker BT at 2 and 4 mm below the ABC. CONCLUSION: SGTDs exhibited a correlation with other PP components, especially crown shape, gingival margin and interdental PH. The relationship between SGTDs and gingival and bone phenotypes depended on the apico-coronal level evaluated. TRIAL REGISTRATION: This study was approved by the Biomedical Research Ethics Committee of Stomatology Hospital of Fujian Medical University (approval no. 2023-24).


Assuntos
Cisto Mamário , Gengiva , Maxila , Masculino , Humanos , Feminino , Estudos Transversais , Maxila/diagnóstico por imagem , Gengiva/diagnóstico por imagem , Coroa do Dente , Tomografia Computadorizada de Feixe Cônico/métodos , China
12.
BMC Oral Health ; 24(1): 442, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605361

RESUMO

BACKGROUND: Radiolucencies found at the root apex in patients with cemento-osseous dysplasia (COD) may be mistaken for periapical cysts (PC) of endodontic origin. The purpose of this study was to examine the utility of quantitative texture analysis using cone-beam computed tomography (CBCT) to differentiate between COD and PC. METHODS: Patients who underwent CBCT at Wonkwang University Daejeon Dental Hospital between January 2019 and December 2022 and were diagnosed with COD and PC by clinical, radiologic, and, if necessary, histopathologic examination were included. Twenty-five patients each were retrospectively enrolled in the COD and PC group. All lesions observed on axial CBCT images were manually segmented using the open-access software MaZda version 4.6 to establish the regions of interest, which were then subjected to texture analysis. Among the 279 texture features obtained, 10 texture features with the highest Fisher coefficients were selected. Statistical analysis was performed using the Mann-Whitney U-test, Welch's t-test, or Student's t-test. Texture features that showed significant differences were subjected to receiver operating characteristics (ROC) curve analysis to evaluate the differential diagnostic ability of COD and PC. RESULTS: The COD group consisted of 22 men and 3 women, while the PC group consisted of 14 men and 11 women, showing a significant difference between the two groups in terms of sex (p=0.003). The 10 selected texture features belonged to the gray level co-occurrence matrix and included the sum of average, sum of entropy, entropy, and difference of entropy. All 10 selected texture features showed statistically significant differences (p<0.05) when comparing patients with COD (n=25) versus those with PC (n=25), osteolytic-stage COD (n=11) versus PC (n=25), and osteolytic-stage COD (n=11) versus cementoblastic-stage COD (n=14). ROC curve analysis to determine the ability to differentiate between COD and PC showed a high area under the curve ranging from 0.96 to 0.98. CONCLUSION: Texture analysis of CBCT images has shown good diagnostic value in the differential diagnosis of COD and PC, which can help prevent unnecessary endodontic treatment, invasive biopsy, or surgical intervention associated with increased risk of infection.


Assuntos
Tumores Odontogênicos , Cisto Radicular , Tomografia Computadorizada de Feixe Cônico Espiral , Masculino , Humanos , Feminino , Cisto Radicular/diagnóstico por imagem , Estudos Retrospectivos , Diagnóstico Diferencial , Tomografia Computadorizada de Feixe Cônico/métodos
13.
Radiat Oncol ; 19(1): 48, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622628

RESUMO

BACKGROUND: Tumor regression and organ movements indicate that a large margin is used to ensure target volume coverage during radiotherapy. This study aimed to quantify inter-fractional movements of the uterus and cervix in patients with cervical cancer undergoing radiotherapy and to evaluate the clinical target volume (CTV) coverage. METHODS: This study analyzed 303 iterative cone beam computed tomography (iCBCT) scans from 15 cervical cancer patients undergoing external beam radiotherapy. CTVs of the uterus (CTV-U) and cervix (CTV-C) contours were delineated based on each iCBCT image. CTV-U encompassed the uterus, while CTV-C included the cervix, vagina, and adjacent parametrial regions. Compared with the planning CTV, the movement of CTV-U and CTV-C in the anterior-posterior, superior-inferior, and lateral directions between iCBCT scans was measured. Uniform expansions were applied to the planning CTV to assess target coverage. RESULTS: The motion (mean ± standard deviation) in the CTV-U position was 8.3 ± 4.1 mm in the left, 9.8 ± 4.4 mm in the right, 12.6 ± 4.0 mm in the anterior, 8.8 ± 5.1 mm in the posterior, 5.7 ± 5.4 mm in the superior, and 3.0 ± 3.2 mm in the inferior direction. The mean CTV-C displacement was 7.3 ± 3.2 mm in the left, 8.6 ± 3.8 mm in the right, 9.0 ± 6.1 mm in the anterior, 8.4 ± 3.6 mm in the posterior, 5.0 ± 5.0 mm in the superior, and 3.0 ± 2.5 mm in the inferior direction. Compared with the other tumor (T) stages, CTV-U and CTV-C motion in stage T1 was larger. A uniform CTV planning treatment volume margin of 15 mm failed to encompass the CTV-U and CTV-C in 11.1% and 2.2% of all fractions, respectively. The mean volume change of CTV-U and CTV-C were 150% and 51%, respectively, compared with the planning CTV. CONCLUSIONS: Movements of the uterine corpus are larger than those of the cervix. The likelihood of missing the CTV is significantly increased due to inter-fractional motion when utilizing traditional planning margins. Early T stage may require larger margins. Personal radiotherapy margining is needed to improve treatment accuracy.


Assuntos
Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Movimento (Física) , Pelve/patologia , Tomografia Computadorizada de Feixe Cônico/métodos , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica
14.
Comput Methods Programs Biomed ; 250: 108158, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38604010

RESUMO

BACKGROUND AND OBJECTIVE: In radiotherapy treatment planning, respiration-induced motion introduces uncertainty that, if not appropriately considered, could result in dose delivery problems. 4D cone-beam computed tomography (4D-CBCT) has been developed to provide imaging guidance by reconstructing a pseudo-motion sequence of CBCT volumes through binning projection data into breathing phases. However, it suffers from artefacts and erroneously characterizes the averaged breathing motion. Furthermore, conventional 4D-CBCT can only be generated post-hoc using the full sequence of kV projections after the treatment is complete, limiting its utility. Hence, our purpose is to develop a deep-learning motion model for estimating 3D+t CT images from treatment kV projection series. METHODS: We propose an end-to-end learning-based 3D motion modelling and 4DCT reconstruction model named 4D-Precise, abbreviated from Probabilistic reconstruction of image sequences from CBCT kV projections. The model estimates voxel-wise motion fields and simultaneously reconstructs a 3DCT volume at any arbitrary time point of the input projections by transforming a reference CT volume. Developing a Torch-DRR module, it enables end-to-end training by computing Digitally Reconstructed Radiographs (DRRs) in PyTorch. During training, DRRs with matching projection angles to the input kVs are automatically extracted from reconstructed volumes and their structural dissimilarity to inputs is penalised. We introduced a novel loss function to regulate spatio-temporal motion field variations across the CT scan, leveraging planning 4DCT for prior motion distribution estimation. RESULTS: The model is trained patient-specifically using three kV scan series, each including over 1200 angular/temporal projections, and tested on three other scan series. Imaging data from five patients are analysed here. Also, the model is validated on a simulated paired 4DCT-DRR dataset created using the Surrogate Parametrised Respiratory Motion Modelling (SuPReMo). The results demonstrate that the reconstructed volumes by 4D-Precise closely resemble the ground-truth volumes in terms of Dice, volume similarity, mean contour distance, and Hausdorff distance, whereas 4D-Precise achieves smoother deformations and fewer negative Jacobian determinants compared to SuPReMo. CONCLUSIONS: Unlike conventional 4DCT reconstruction techniques that ignore breath inter-cycle motion variations, the proposed model computes both intra-cycle and inter-cycle motions. It represents motion over an extended timeframe, covering several minutes of kV scan series.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada Quadridimensional , Planejamento da Radioterapia Assistida por Computador , Respiração , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Movimento , Movimento (Física) , Aprendizado Profundo
15.
J Appl Clin Med Phys ; 25(5): e14337, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38576183

RESUMO

PURPOSE: The quality of on-board imaging systems, including cone-beam computed tomography (CBCT), plays a vital role in image-guided radiation therapy (IGRT) and adaptive radiotherapy. Recently, there has been an upgrade of the CBCT systems fused in the O-ring linear accelerators called HyperSight, featuring a high imaging performance. As the characterization of a new imaging system is essential, we evaluated the image quality of the HyperSight system by comparing it with Halcyon 3.0 CBCT and providing benchmark data for routine imaging quality assurance. METHODS: The HyperSight features ultra-fast scan time, a larger kilovoltage (kV) detector, a more substantial kV tube, and an advanced reconstruction algorithm. Imaging protocols in the two modes of operation, treatment mode with IGRT and the CBCT for planning (CBCTp) mode were evaluated and compared with Halcyon 3.0 CBCT. Image quality metrics, including spatial resolution, contrast resolution, uniformity, noise, computed tomography (CT) number linearity, and calibration error, were assessed using a Catphan and an electron density phantom and analyzed with TotalQA software. RESULTS: HyperSight demonstrated substantial improvements in contrast-to-noise ratio and noise in both IGRT and CBCTp modes compared to Halcyon 3.0 CBCT. CT number calibration error of HyperSight CBCTp mode (1.06%) closely matches that of a full CT scanner (0.72%), making it suitable for adaptive planning. In addition, the advanced hardware of HyperSight, such as ultra-fast scan time (5.9 s) or 2.5 times larger heat unit capacity, enhanced the clinical efficiency in our experience. CONCLUSIONS: HyperSight represented a significant advancement in CBCT imaging. With its image quality, CT number accuracy, and ultra-fast scans, HyperSight has a potential to transform patient care and treatment outcomes. The enhanced scan speed and image quality of HyperSight are expected to significantly improve the quality and efficiency of treatment, particularly benefiting patients.


Assuntos
Algoritmos , Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador , Aceleradores de Partículas , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Aceleradores de Partículas/instrumentação , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Garantia da Qualidade dos Cuidados de Saúde/normas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
16.
Biomed Phys Eng Express ; 10(3)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38588646

RESUMO

Objective.In current radiograph-based intra-fraction markerless target-tracking, digitally reconstructed radiographs (DRRs) from planning CTs (CT-DRRs) are often used to train deep learning models that extract information from the intra-fraction radiographs acquired during treatment. Traditional DRR algorithms were designed for patient alignment (i.e.bone matching) and may not replicate the radiographic image quality of intra-fraction radiographs at treatment. Hypothetically, generating DRRs from pre-treatment Cone-Beam CTs (CBCT-DRRs) with DRR algorithms incorporating physical modelling of on-board-imagers (OBIs) could improve the similarity between intra-fraction radiographs and DRRs by eliminating inter-fraction variation and reducing image-quality mismatches between radiographs and DRRs. In this study, we test the two hypotheses that intra-fraction radiographs are more similar to CBCT-DRRs than CT-DRRs, and that intra-fraction radiographs are more similar to DRRs from algorithms incorporating physical models of OBI components than DRRs from algorithms omitting these models.Approach.DRRs were generated from CBCT and CT image sets collected from 20 patients undergoing pancreas stereotactic body radiotherapy. CBCT-DRRs and CT-DRRs were generated replicating the treatment position of patients and the OBI geometry during intra-fraction radiograph acquisition. To investigate whether the modelling of physical OBI components influenced radiograph-DRR similarity, four DRR algorithms were applied for the generation of CBCT-DRRs and CT-DRRs, incorporating and omitting different combinations of OBI component models. The four DRR algorithms were: a traditional DRR algorithm, a DRR algorithm with source-spectrum modelling, a DRR algorithm with source-spectrum and detector modelling, and a DRR algorithm with source-spectrum, detector and patient material modelling. Similarity between radiographs and matched DRRs was quantified using Pearson's correlation and Czekanowski's index, calculated on a per-image basis. Distributions of correlations and indexes were compared to test each of the hypotheses. Distribution differences were determined to be statistically significant when Wilcoxon's signed rank test and the Kolmogorov-Smirnov two sample test returnedp≤ 0.05 for both tests.Main results.Intra-fraction radiographs were more similar to CBCT-DRRs than CT-DRRs for both metrics across all algorithms, with allp≤ 0.007. Source-spectrum modelling improved radiograph-DRR similarity for both metrics, with allp< 10-6. OBI detector modelling and patient material modelling did not influence radiograph-DRR similarity for either metric.Significance.Generating DRRs from pre-treatment CBCT-DRRs is feasible, and incorporating CBCT-DRRs into markerless target-tracking methods may promote improved target-tracking accuracies. Incorporating source-spectrum modelling into a treatment planning system's DRR algorithms may reinforce the safe treatment of cancer patients by aiding in patient alignment.


Assuntos
Algoritmos , Tomografia Computadorizada de Feixe Cônico , Neoplasias Pancreáticas , Radiocirurgia , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Radiocirurgia/métodos , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Aprendizado Profundo , Tomografia Computadorizada por Raios X/métodos , Pâncreas/diagnóstico por imagem , Pâncreas/cirurgia , Imagens de Fantasmas
17.
BMC Oral Health ; 24(1): 415, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38575886

RESUMO

BACKGROUND: The objective of the present study was to evaluate the reliability of an augmented reality drilling approach and a freehand drilling technique for the autotransplantation of single-rooted teeth. MATERIALS AND METHODS: Forty samples were assigned to the following surgical techniques for drilling guidance of the artificial sockets: A. augmented reality technique (AR) (n = 20) and B. conventional free-hand technique (FT) (n = 20). Then, two models with 10 teeth each were submitted to a preoperative cone-beam computed tomography (CBCT) scan and a digital impression by a 3D intraoral scan. Afterwards, the autotrasplanted teeth were planned in a 3D dental implant planning software and transferred to the augmented reality device. Then, a postoperative CBCT scan was performed. Data sets from postoperative CBCT scans were aligned to the planning in the 3D implant planning software to analize the coronal, apical and angular deviations. Student's t-test and Mann-Whitney non-parametric statistical analysis were used to analyze the results. RESULTS: No statistically significant differences were shown at coronal (p = 0.123) and angular (p = 0.340) level; however, apical deviations between AR and FT study groups (p = 0.008) were statistically significant different. CONCLUSION: The augmented reality appliance provides higher accuracy in the positioning of single-root autotransplanted teeth compared to the conventional free-hand technique.


Assuntos
Realidade Aumentada , Implantes Dentários , Cirurgia Assistida por Computador , Humanos , Transplante Autólogo , Reprodutibilidade dos Testes , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico/métodos , Imageamento Tridimensional
18.
Sci Rep ; 14(1): 9563, 2024 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-38671043

RESUMO

Extracting longitudinal image quantitative data, known as delta-radiomics, has the potential to capture changes in a patient's anatomy throughout the course of radiation treatment for prostate cancer. Some of the major challenges of delta-radiomics studies are contouring the structures for individual fractions and accruing patients' data in an efficient manner. The manual contouring process is often time consuming and would limit the efficiency of accruing larger sample sizes for future studies. The problem is amplified because the contours are often made by highly trained radiation oncologists with limited time to dedicate to research studies of this nature. This work compares the use of automated prostate contours generated using a deformable image-based algorithm to make predictive models of genitourinary and changes in total international prostate symptom score in comparison to manually contours for a cohort of fifty patients. Area under the curve of manual and automated models were compared using the Delong test. This study demonstrated that the delta-radiomics models were similar for both automated and manual delta-radiomics models.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Algoritmos , Idoso , Pessoa de Meia-Idade , Lesões por Radiação/etiologia , Radiômica
19.
Medicina (Kaunas) ; 60(4)2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38674174

RESUMO

Background and Objectives: Ectodermal dysplasia (ED)-a genetic disorder-is characterized by severe tooth deficiency. We compared the mandibular volume and the sagittal and horizontal mandibular widths between patients with ED (ED group) and individuals without tooth deficiency (control group) using three-dimensional modeling. We hypothesized that the mandibular volume differs in ED cases owing to congenital tooth deficiency. Materials and Methods: We used previously obtained cone-beam computed tomography (CBCT) images of 13 patients with ED. The control group data comprised retrospective CBCT images of patients of similar age and sex with a skeletal relationship of class 1. Further, using the three-dimensional image analysis software, the tooth crowns were separated from the mandible, the mandible was reconstructed and the gonion-to-gonion distance in the mandible was marked, the distance to the menton point was measured, and the distance between the two condyles was measured and compared with the control group. Results: Overall, 46.2% and 53.8% of the participants were men and women, respectively. In the ED group, the mean age of the participants was 15.46 (range, 6-24) years, and the mean number of mandibular teeth was 4.62. Notably, the edentulous mandible volume of the ED group (27.020 mm3) was statistically significantly smaller than that of the control group (49.213 mm3) (p < 0.001). There was no difference between the two groups in terms of the marked points. For data analysis, the Shapiro-Wilk test, independent samples t-test, and Mann-Whitney U test were used. Conclusions: It has been considered that mandible volume does not develop in ED cases because of missing teeth. Modern practices, such as the CBCT technique and three-dimensional software, may be effective in identifying the true morphologic features, especially in patients with genetic syndromes affecting the maxillofacial structure.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Displasia Ectodérmica , Imageamento Tridimensional , Mandíbula , Humanos , Feminino , Masculino , Mandíbula/anormalidades , Mandíbula/diagnóstico por imagem , Adolescente , Tomografia Computadorizada de Feixe Cônico/métodos , Displasia Ectodérmica/diagnóstico por imagem , Displasia Ectodérmica/fisiopatologia , Criança , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Adulto Jovem , Adulto
20.
Phys Med Biol ; 69(10)2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38593826

RESUMO

Objective. Newer cone-beam computed tomography (CBCT) imaging systems offer reconstruction algorithms including metal artifact reduction (MAR) and extended field-of-view (eFoV) techniques to improve image quality. In this study a new CBCT imager, the new Varian HyperSight CBCT, is compared to fan-beam CT and two CBCT imagers installed in a ring-gantry and C-arm linear accelerator, respectively.Approach. The image quality was assessed for HyperSight CBCT which uses new hardware, including a large-size flat panel detector, and improved image reconstruction algorithms. The decrease of metal artifacts was quantified (structural similarity index measure (SSIM) and root-mean-squared error (RMSE)) when applying MAR reconstruction and iterative reconstruction for a dental and spine region using a head-and-neck phantom. The geometry and CT number accuracy of the eFoV reconstruction was evaluated outside the standard field-of-view (sFoV) on a large 3D-printed chest phantom. Phantom size dependency of CT numbers was evaluated on three cylindrical phantoms of increasing diameter. Signal-to-noise and contrast-to-noise were quantified on an abdominal phantom.Main results. In phantoms with streak artifacts, MAR showed comparable results for HyperSight CBCT and CT, with MAR increasing the SSIM (0.97-0.99) and decreasing the RMSE (62-55 HU) compared to iterative reconstruction without MAR. In addition, HyperSight CBCT showed better geometrical accuracy in the eFoV than CT (Jaccard Conformity Index increase of 0.02-0.03). However, the CT number accuracy outside the sFoV was lower than for CT. The maximum CT number variation between different phantom sizes was lower for the HyperSight CBCT imager (∼100 HU) compared to the two other CBCT imagers (∼200 HU), but not fully comparable to CT (∼50 HU).Significance. This study demonstrated the imaging performance of the new HyperSight CBCT imager and the potential of applying this CBCT system in more advanced scenarios by comparing the quality against fan-beam CT.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Humanos , Artefatos , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA