Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
1.
IEEE Trans Med Imaging ; 42(4): 1009-1020, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36383595

RESUMO

Optical Coherence Tomography Angiography (OCTA), a functional extension of OCT, has the potential to replace most invasive fluorescein angiography (FA) exams in ophthalmology. So far, OCTA's field of view is however still lacking behind fluorescence fundus photography techniques. This is problematic, because many retinal diseases manifest at an early stage by changes of the peripheral retinal capillary network. It is therefore desirable to expand OCTA's field of view to match that of ultra-widefield fundus cameras. We present a custom developed clinical high-speed swept-source OCT (SS-OCT) system operating at an acquisition rate 8-16 times faster than today's state-of-the-art commercially available OCTA devices. Its speed allows us to capture ultra-wide fields of view of up to 90 degrees with an unprecedented sampling density and hence extraordinary resolution by merging two single shot scans with 60 degrees in diameter. To further enhance the visual appearance of the angiograms, we developed for the first time a three-dimensional deep learning based algorithm for denoising volumetric OCTA data sets. We showcase its imaging performance and clinical usability by presenting images of patients suffering from diabetic retinopathy.


Assuntos
Angiografia , Oftalmologia , Doenças Retinianas , Tomografia de Coerência Óptica , Humanos , Retinopatia Diabética/diagnóstico por imagem , Angiofluoresceinografia/normas , Doenças Retinianas/diagnóstico por imagem , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/normas , Angiografia/instrumentação , Angiografia/métodos , Angiografia/normas , Oftalmologia/instrumentação , Oftalmologia/métodos
2.
Coron Artery Dis ; 33(2): 114-124, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34411011

RESUMO

OBJECTIVES: We investigated clinical determinants of disease burden and vulnerability using optical coherence tomography (OCT) co-registered with intravascular ultrasound (IVUS) in a large cohort of patients. METHODS: A total of 704 patients [44.5% with acute coronary syndromes (ACS)] underwent coronary intervention. IVUS plaque burden and OCT lipid, macrophage and calcium indices and the presence of thrombus, plaque rupture and thin-cap fibroatheroma (TCFA) were analyzed. RESULTS: Median patient age was 66 years with 81.8% men, 34.4% with diabetes mellitus and 15.5% with preadmission statins. Median lesion length was 25.7 mm, and 33.0% had a TCFA. Adjusted models indicated (1) older patient age was related to more calcium, but fewer macrophages; (2) men were related to more thrombus with plaque rupture while women had more thrombus without plaque rupture; (3) ACS presentation was related to morphological acute thrombotic events (more thrombus with/without rupture) and plaque vulnerability (more TCFA, more lipid and macrophages and larger plaque burden); (4) diabetes mellitus was related to a greater atherosclerotic disease burden (more lipid and calcium and larger plaque burden) and more thrombus without rupture; (5) hypertension was related to more macrophages; (6) current smoking was related to less calcium; and (7) renal insufficiency and preadmission statin therapy were not independently associated with IVUS or OCT plaque morphology. CONCLUSION: Patient characteristics, especially diabetes mellitus and aging, affect underlying atherosclerotic burden, among which a greater lipidic burden along with sex differences influence local thrombotic morphology that affects clinical presentation.


Assuntos
Doença da Artéria Coronariana/etiologia , Tomografia de Coerência Óptica/normas , Ultrassonografia de Intervenção/normas , Idoso , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/fisiopatologia , Efeitos Psicossociais da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/estatística & dados numéricos , Ultrassonografia de Intervenção/métodos , Ultrassonografia de Intervenção/estatística & dados numéricos
3.
Sci Rep ; 11(1): 23832, 2021 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-34903817

RESUMO

This is a prospective observational study to establish the short- and long-term repeatability of measurements of peripapillary optical coherence tomography angiography (OCTA) parameters in healthy eyes and identify factors affecting long-term repeatability. We enrolled 84 healthy eyes. Participants with a history of any ophthalmic disease (except high myopia) or intraocular surgery were excluded from the study. An experienced examiner performed OCTA using disc-centered 6 × 6 mm scans. All examinations were conducted twice at 5-min intervals at the initial visit and repeated at least 6 months later. For short-term repeatability, the coefficient of variation (CV) was 2.94-4.22% and the intraclass correlation coefficient (ICC) was 0.840-0.934. For long-term repeatability, the CV was 2.73-3.84% and the ICC was 0.737-0.934. Multivariate analyses showed that the axial length (AL) (B = 0.970; p = 0.002) and mean signal strength (SS) (B = - 2.028; p < 0.001) significantly affected long-term repeatability. Measurements of peripapillary OCTA parameters exhibited excellent short-term and good long-term repeatability in healthy individuals. The mean SS and AL affected long-term repeatability and should be considered while interpreting peripapillary OCTA images.


Assuntos
Angiografia/métodos , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Angiografia/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/normas
4.
Sci Rep ; 11(1): 19886, 2021 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-34615979

RESUMO

This study aims to quantitatively investigate the optical coherence tomographic angiography (OCTA) findings of capillary congestion and its association with macular edema (ME) recurrence in chronic branch retinal vein occlusion (BRVO). We retrospectively reviewed the medical records of 115 consecutive patients with major ischemic BRVO who reached stable macula (without ME for two consecutive visits) at baseline (the first visit within the stable period). All patients were classified into a recurrence or non-recurrence groups depending on ME recurrence. Capillary congestion of deep capillary plexuses (DCP-C) and other abnormal capillary lesions were segmented, and their areas, vascular densities, and mean retinal thicknesses (MRT) were calculated. The main outcomes were differences between the two groups and risk factors for recurrence among baseline and OCTA parameters. A total of 76 eyes were included, of which 22 (28.9%) recurred. DCP-C existed in all eyes at baseline. MRT of DCP-C (p = 0.006) was greater in the recurrence group. Greater MRT of DCP-C (OR: 1.044; p = 0.002) and more frequent intravitreal injections (OR: 1.803; p < 0.001) were associated with a higher risk of relapsing ME. DCP-C may contribute to the anatomical stability of chronic BRVO and simultaneously be the source of ME.


Assuntos
Edema Macular/diagnóstico , Edema Macular/etiologia , Oclusão da Veia Retiniana/diagnóstico por imagem , Oclusão da Veia Retiniana/patologia , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Tomografia de Coerência Óptica/métodos , Idoso , Biomarcadores , Doença Crônica , Comorbidade , Suscetibilidade a Doenças , Feminino , Angiofluoresceinografia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Recidiva , Oclusão da Veia Retiniana/complicações , Estudos Retrospectivos , Fatores de Risco , Tomografia de Coerência Óptica/normas
5.
Am J Respir Crit Care Med ; 204(10): 1164-1179, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-34375171

RESUMO

Rationale: Early, accurate diagnosis of interstitial lung disease (ILD) informs prognosis and therapy, especially in idiopathic pulmonary fibrosis (IPF). Current diagnostic methods are imperfect. High-resolution computed tomography has limited resolution, and surgical lung biopsy (SLB) carries risks of morbidity and mortality. Endobronchial optical coherence tomography (EB-OCT) is a low-risk, bronchoscope-compatible modality that images large lung volumes in vivo with microscopic resolution, including subpleural lung, and has the potential to improve the diagnostic accuracy of bronchoscopy for ILD diagnosis. Objectives: We performed a prospective diagnostic accuracy study of EB-OCT in patients with ILD with a low-confidence diagnosis undergoing SLB. The primary endpoints were EB-OCT sensitivity/specificity for diagnosis of the histopathologic pattern of usual interstitial pneumonia (UIP) and clinical IPF. The secondary endpoint was agreement between EB-OCT and SLB for diagnosis of the ILD fibrosis pattern. Methods: EB-OCT was performed immediately before SLB. The resulting EB-OCT images and histopathology were interpreted by blinded, independent pathologists. Clinical diagnosis was obtained from the treating pulmonologists after SLB, blinded to EB-OCT. Measurements and Main Results: We enrolled 31 patients, and 4 were excluded because of inconclusive histopathology or lack of EB-OCT data. Twenty-seven patients were included in the analysis (16 men, average age: 65.0 yr): 12 were diagnosed with UIP and 15 with non-UIP ILD. Average FVC and DlCO were 75.3% (SD, 18.5) and 53.5% (SD, 16.4), respectively. Sensitivity and specificity of EB-OCT was 100% (95% confidence interval, 75.8-100.0%) and 100% (79.6-100%), respectively, for both histopathologic UIP and clinical diagnosis of IPF. There was high agreement between EB-OCT and histopathology for diagnosis of ILD fibrosis pattern (weighted κ: 0.87 [0.72-1.0]). Conclusions: EB-OCT is a safe, accurate method for microscopic ILD diagnosis, as a complement to high-resolution computed tomography and an alternative to SLB.


Assuntos
Broncoscopia/métodos , Broncoscopia/normas , Confiabilidade dos Dados , Fibrose Pulmonar Idiopática/diagnóstico , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/normas , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
6.
Ophthalmol Retina ; 5(10): 981-990, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33388471

RESUMO

PURPOSE: To develop a consensus nomenclature for OCT angiography (OCTA) findings in retinal vascular diseases. DESIGN: Online survey using the Delphi Method. PARTICIPANTS: Members of The Retina Society, the European Society of Retina Specialists, and the Japanese Retina and Vitreous Society. METHODS: An online questionnaire on OCTA terminology in retinal vascular diseases was sent to members of The Retina Society, the European Society of Retina Specialists, and the Japanese Retina and Vitreous Society. The respondents were divided into 2 groups ("experts" vs. "users") according to the number of their publications in this field. The respondents who had more than 5 publications in the field of OCTA and retinal vascular diseases were considered the OCTA "experts" group. MAIN OUTCOME MEASURES: Consensus and near consensus on OCTA nomenclature. RESULTS: The complete responses of 85 retina specialists were included in the analysis. Thirty-one were categorized as "experts." There was a consensus in both groups that OCTA parameters such as foveal avascular zone (FAZ) parameters, areas of nonperfusion, and presence of neovascularization (NV) should be implemented in the identification and staging of diabetic retinopathy (DR) and that OCTA can be applied to differentiate between ischemic and nonischemic retinal vein occlusion (RVO). Diabetic macular ischemia (DMI) also can be assessed via OCTA. Further, there was consensus that the terminology should differ on the basis of the underlying causes of decreased vascular flow signal. There was disagreement in other areas, such as which terms should be applied to describe decreased OCTA signal from different causes, the definition of wide-field OCTA, and how to quantify DMI and area of decreased flow signal. These discrepancies form the basis for the upcoming expert Delphi rounds that aim to develop a standardized OCTA nomenclature. CONCLUSIONS: Although there was agreement in some areas, significant differences were found in many areas of OCTA terminology among all respondents, but also between the expert and user groups. This indicates the need for standardization of the nomenclature among all specialists in the field of retinal vascular diseases.


Assuntos
Angiografia por Tomografia Computadorizada/normas , Doenças Retinianas/diagnóstico por imagem , Vasos Retinianos/diagnóstico por imagem , Terminologia como Assunto , Tomografia de Coerência Óptica/normas , Velocidade do Fluxo Sanguíneo , Consenso , União Europeia , Angiofluoresceinografia , Humanos , Japão , Oftalmologia/organização & administração , Fluxo Sanguíneo Regional/fisiologia , Doenças Retinianas/fisiopatologia , Vasos Retinianos/fisiopatologia , Sociedades Médicas , Inquéritos e Questionários
7.
J Neurointerv Surg ; 12(12): 1242-1246, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32487765

RESUMO

BACKGROUND: Optical coherence tomography (OCT) is an ultra-high resolution real-time intravascular imaging method that is gaining interest in cerebrovascular applications. OBJECTIVE: To compare, in a rabbit elastase aneurysm model, digital subtraction angiography (DSA) and OCT as diagnostic tools for the assessment of aneurysmal remnants and baseline characteristics of aneurysms after flow diverter (FD) implantation. METHODS: With Institutional Animal Care and Use Committee approval, saccular aneurysms were created in 28 rabbits and treated with Derivo FDs. DSA was performed before, and immediately after, stent implantation. As a follow-up, DSA and OCT were performed 28 days after device implantation. RESULTS: DSA and OCT were successfully performed in 23 cases. OCT could not be achieved in 5 cases owing to navigational difficulties in the stent lumen with the OCT catheter. Residual aneurysms were significantly more often visible with OCT (18/23 (78%) than with DSA 12/23 (52%), p = 0.031). CONCLUSION: OCT was more sensitive than conventional angiography for the assessment of residual aneurysms at 28 days after FD implantation in an animal model.


Assuntos
Angiografia Digital/normas , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Stents Metálicos Autoexpansíveis/normas , Tomografia de Coerência Óptica/normas , Angiografia Digital/métodos , Animais , Modelos Animais de Doenças , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/normas , Elastase Pancreática , Coelhos , Tomografia de Coerência Óptica/métodos
8.
Br J Ophthalmol ; 104(2): 162-166, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31036586

RESUMO

PURPOSE: To evaluate the impact of segmentation error on vessel density measurements in healthy eyes and eyes with diabetic macular oedema (DMO). METHODS: In this prospective, comparative, non-interventional study, enface optical coherence tomography angiography (OCTA) images of the macula from healthy eyes and eyes with DMO were acquired. Two expert graders assessed and corrected the segmentation error. The rate of segmentation error and the changes in vessel density and inner retinal thickness after correction of the segmentation error were recorded and compared between the two groups. RESULTS: 20 eyes with DMO and 24 healthy eyes were evaluated. Intergrader agreement was excellent (intraclass correlation coefficient ≥0.9) for all parameters in both groups. The rate of segmentation error was 33% and 100% in healthy and diabetic eyes, respectively (p<0.001). Nine healthy eyes (37.5%) and all eyes with DMO (100%) were noted to exhibit a change in at least one of the foveal or parafoveal vessel density measurements. The rate of any change in foveal and parafoveal vessel densities in both the superficial and deep capillary plexus was statistically significantly higher in the diabetic group (all p<0.001). No statistically significant change was observed in mean vessel density (superficial and deep capillary plexuses) after correction of the segmentation error in healthy and DMO eyes (All p>0.05). However, the mean absolute change in the vessel density measurements was statistically significantly higher in the diabetic group (all p<0.05). The mean absolute change in superficial and deep inner retinal thickness was statistically significantly higher in DMO (p=0.02 and p=0.002, respectively). CONCLUSIONS: In this study, misidentification of retinal layers and consequent vessel density measurement error occurred in all eyes with DMO and in one-third of healthy eyes. The segmentation error should be checked and manually corrected in the OCTA vessel density measurements, especially in the presence of macular oedema.


Assuntos
Retinopatia Diabética/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/normas , Edema Macular/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia de Coerência Óptica/normas
9.
Photodiagnosis Photodyn Ther ; 27: 298-304, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31185324

RESUMO

BACKGROUND: Bladder cancer is the fourth most common malignancy in men and a considerable disease burden globally. Multiple studies have focused on the accuracy of optical coherence tomography for bladder cancer diagnosis; however, the findings are inconsistent. Here, we assessed the accuracy of optical coherence tomography for bladder cancer diagnosis. METHODS: Embase, PubMed, Medline, Web of Science, and the Cochrane Library database were searched for relevant studies from the earliest date available through March 11, 2019. Studies evaluating the accuracy of optical coherence tomography bladder cancer diagnosis were included. Pooled sensitivity, specificity, and area under the curve values of weighted symmetric summary receiver operating curves, were calculated at the per-lesion level. RESULTS: Eleven studies, with a total of 1933 lesions, were included in the final analysis. The pooled results indicated that optical coherence tomography can differentiate bladder cancer from benign lesions: sensitivity, 94.9% (95% confidence interval: 92.7%-96.6%); specificity, 84.6% (95% confidence interval: 82.6%-86.4%); area under the curve, 0.97. Moreover, compared with optical coherence tomography alone, combined optical coherence tomography and fluorescence cystoscopy increased the diagnostic accuracy (sensitivity, 94.3% vs. 87.3%; specificity, 89.2% vs. 73.9%). Cross-polarization optical coherence tomography could also distinguish bladder cancer from normal tissue: sensitivity, 92.0% (95% confidence interval: 87.0%-95.6%); specificity, 84.4% (95% confidence interval: 81.7%-86.9%); area under the curve, 0.95. CONCLUSIONS: Optical coherence tomography can accurately differentiate malignant from benign bladder lesions, particularly when combined with fluorescence cystoscopy.


Assuntos
Tomografia de Coerência Óptica/métodos , Neoplasias da Bexiga Urinária/diagnóstico , Cistoscopia/métodos , Fluorescência , Humanos , Sensibilidade e Especificidade , Tomografia de Coerência Óptica/normas , Neoplasias da Bexiga Urinária/patologia
10.
J Fr Ophtalmol ; 42(7): 762-777, 2019 Sep.
Artigo em Francês | MEDLINE | ID: mdl-31174880

RESUMO

PURPOSE: To update the medical literature on the diagnostic and therapeutic approach to polypoidal choroidal vasculopathy (PCV) and to propose a treatment algorithm in agreement with French market approval, supported by the France Macula Federation (FFM). METHODS: Literature review and expert opinion. RESULTS: The diagnosis of PCV is based on multimodal imaging, including indocyanine green angiography (ICGA), which is considered the gold standard for the diagnosis of PCV. Regarding the therapeutic management of PCV, the FFM recommends treating PCV first-line either by monotherapy with intra-vitreal anti-vascular endothelial growth factor (anti-VEGF) injections, or by a combined treatment of photodynamic therapy (PDT) with Verteporfin and intra-vitreal anti-VEGF injections, depending on the location of the PCV.


Assuntos
Neovascularização de Coroide/diagnóstico , Neovascularização de Coroide/terapia , Oftalmologia/normas , Pólipos/diagnóstico , Pólipos/terapia , Inibidores da Angiogênese/uso terapêutico , Doenças da Coroide/complicações , Doenças da Coroide/diagnóstico , Doenças da Coroide/terapia , Neovascularização de Coroide/complicações , Técnicas de Diagnóstico Oftalmológico/normas , Angiofluoresceinografia/métodos , Angiofluoresceinografia/normas , França , Humanos , Verde de Indocianina , Oftalmologia/organização & administração , Fotoquimioterapia/métodos , Fotoquimioterapia/normas , Fármacos Fotossensibilizantes/uso terapêutico , Pólipos/complicações , Sociedades Médicas/normas , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/normas
11.
Sci Rep ; 9(1): 2998, 2019 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-30816153

RESUMO

Colorectal cancer diagnosis currently relies on histological detection of endoluminal neoplasia in biopsy specimens. However, clinical visual endoscopy provides no quantitative subsurface cancer information. In this ex vivo study of nine fresh human colon specimens, we report the first use of quantified subsurface scattering coefficient maps acquired by swept-source optical coherence tomography to reveal subsurface abnormities. We generate subsurface scattering coefficient maps with a novel wavelet-based-curve-fitting method that provides significantly improved accuracy. The angular spectra of scattering coefficient maps of normal tissues exhibit a spatial feature distinct from those of abnormal tissues. An angular spectrum index to quantify the differences between the normal and abnormal tissues is derived, and its strength in revealing subsurface cancer in ex vivo samples is statistically analyzed. The study demonstrates that the angular spectrum of the scattering coefficient map can effectively reveal subsurface colorectal cancer and potentially provide a fast and more accurate diagnosis.


Assuntos
Colo/diagnóstico por imagem , Neoplasias Colorretais/patologia , Tomografia de Coerência Óptica/métodos , Colo/patologia , Neoplasias Colorretais/diagnóstico por imagem , Humanos , Sensibilidade e Especificidade , Tomografia de Coerência Óptica/normas
12.
Ophthalmic Plast Reconstr Surg ; 35(5): 438-443, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30688722

RESUMO

PURPOSE: CT is the standard of care for assessment of ocular and orbital trauma; however, artifacts from metallic foreign bodies can limit the utility of CT. The authors hypothesize that implementation of metal artifact reduction techniques can improve image quality and diagnostic confidence for a diverse group of interpreters. METHODS: A case series of ten subjects with retained periocular metallic foreign bodies imaged with CT were identified retrospectively from a large urban trauma center. Postacquisition images were processed with an iterative-based metal streak artifact reduction software. The severity of the metal streak artifact was assessed by clinicians including radiologists (4), ophthalmologists (4), and oculoplastic specialists (3) using a numeric scale to grade images on seven clinically relevant criteria. Each image was also analyzed to measure the size of the artifact and degree of streaking. RESULTS: Overall confidence in diagnosis and severity of metallic streak was improved with metallic artifact reduction (p < 0.001, Wilcoxon signed-rank test). Similarly, confidence in assessing specific features-including extra-ocular muscle, optic nerve, globe rupture, orbital fracture and identification of foreign bodies-was improved after metallic artifact reduction (p < 0.001, Wilcoxon signed-rank test). The standard deviation of pixel intensity for a path surrounding the foreign body as well as the area of the streak artifact decreased in the metallic artifact reduction-processed images (p < 0.001, paired t test). CONCLUSIONS: Metal artifact reduction in CT has potential benefits in improving image quality and reader confidence for periocular trauma cases in real-world settings.


Assuntos
Corpos Estranhos no Olho/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adolescente , Adulto , Idoso , Artefatos , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Estudos Retrospectivos , Software , Tomografia de Coerência Óptica/normas , Adulto Jovem
13.
BMC Ophthalmol ; 19(1): 30, 2019 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-30678658

RESUMO

BACKGROUND: To evaluate the accuracy of biometric measurements by a swept-source optical coherence tomography (SS-OCT) based biometry for intraocular lens (IOL) power calculation. METHODS: This retrospective observational study enrolled 431 patients undergoing cataract surgery. The charts were reviewed to investigate the failure rate of axial length (AL) measurement of the SS-OCT biometer, partial coherence interferometry (PCI), and A-scan ultrasonography (US) according to cataract type and severity. AL and keratometry in 164 eyes with the same IOL inserted were measured using the SS-OCT biometer, PCI, and A-scan US. The SRK/T formula was used to calculate IOL power. The mean absolute error (MAE) and percentage of eyes with a prediction error (PE) of ±0.50 D were compared. RESULTS: The AL measurement failure rate was 0.00% for A-scan US, 2.32% for the SS-OCT biometer, and 15.31% for PCI. The number of eyes measured using three devices (SS-OCT biometer, PCI, and A-scan US) was 128 (Group A) and the number of eyes measured using two devices (SS-OCT biometer and A-scan US) was 36 (Group B). The score of posterior subcapsular opacity was significantly different between two groups (p < .001). The SS-OCT biometer and PCI showed significantly lower MAE compared to A-scan US in Group A (p = 0.027). Using SS-OCT biometer, MAE showed no significant difference between Group A (0.36 ± 0.27) and Group B (0.36 ± 0.31) (p = 0.785). Whereas, MAE of A-scan US was significantly higher than Group A (0.47 ± 0.39) in Group B (0.64 ± 0.36) (p = 0.023). CONCLUSIONS: Using biometry with advanced OCT is useful in clinical practice as it is more effective in obtaining biometric measurements in the eyes with PSC and provides accurate measurements for IOL power calculation regardless of cataract type and severity. TRIAL REGISTRATION: Retrospectively registered. Registration number: KC16RISI1020 . Registered 03 January 2018.


Assuntos
Biometria/métodos , Extração de Catarata , Interferometria/instrumentação , Lentes Intraoculares , Tomografia de Coerência Óptica/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Comprimento Axial do Olho/fisiologia , Extração de Catarata/métodos , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Adulto Jovem
14.
PLoS One ; 14(1): e0210505, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30682050

RESUMO

OBJECTIVE: To analyze quality and frequency of OCTA artifacts and to evaluate their impact on the interpretability of OCTA images. DESIGN: 75 patients with diabetic retinopathy (DR), retinal artery occlusion (RAO), retinal vein occlusion (RVO), or neovascular age-related macular degeneration (nAMD) and healthy controls were enrolled in this cross-sectional study in the outpatient department of a tertiary eye care center. METHODS: All participants underwent an OCTA examination (spectral domain OCT Cirrus 5000 equipped with the AngioPlex module). OCTA scans were analyzed independently by two experienced ophthalmologists. Frequency of various artifacts for the entire OCTA scan and for different segmentation layers and the grading of OCTA interpretability were investigated. RESULTS: The analysis of 75 eyes of 38 women and 37 men between 24 and 94 years were included. Six eyes had no retinal disease, 19 eyes had nAMD, 16 had DR, 19 eyes had RVO, and 15 eyes showed RAO. A macular edema (ME) was present in 40 of the diseased eyes. Projection artifacts occurred in all eyes in any structure below the superficial retinal vessel layer, segmentation and motion artifacts were found in 55% (41/75) and 49% (37/75) of eyes, respectively. Other artifacts occurred less frequently. Segmentation artifacts were significantly more frequent in diseased than in healthy eyes (p<0.01). Qualitative assessment of OCTA images was graded as excellent in 65% and sufficient in 25% of cases, adding up to 91% images deemed acceptable for examination. Presence of ME was associated with a significantly poorer interpretability (p<0.01). CONCLUSION AND RELEVANCE: Various artifacts appear at different frequencies in OCTA images. Nevertheless, a qualitative assessment of the OCTA images is almost always possible. Good knowledge of possible artifacts and critical analysis of the complete OCTA dataset are essential for correct clinical interpretation and determining a precise clinical diagnosis.


Assuntos
Artefatos , Olho/diagnóstico por imagem , Angiofluoresceinografia/métodos , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Retinopatia Diabética/diagnóstico por imagem , Olho/fisiopatologia , Feminino , Angiofluoresceinografia/normas , Humanos , Edema Macular/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Oclusão da Veia Retiniana/diagnóstico por imagem , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/normas , Acuidade Visual/fisiologia , Adulto Jovem
15.
Br J Ophthalmol ; 103(1): 88-93, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29605814

RESUMO

AIMS: The aim of our study was to image choroidal lesions with swept-source optical coherence tomography (SS-OCT) and to identify the morphological characteristics associated with optimal visualisation. METHODS: This was a prospective, cross-sectional study. Patients with choroidal melanocytic lesions <3 mm in thickness on B-scan ultrasonography were recruited. All participants underwent SS-OCT. On SS-OCT we evaluated qualitative (eg, lesion outline, detection of scleral-choroidal interface and quality of the image) and quantitative (measurement of maximum lesion thickness and the largest basal diameter) parameters. Probability of optimal image quality was examined using ordered logistic regression models. The main outcome measure was quality of the choroidal lesion images on SS-OCT, defined as: optimal, suboptimal or poor. RESULTS: We included 85 choroidal lesions of 82 patients. There were 24 choroidal lesions (29%) for which image quality was classified as optimal, 31 lesions (37%) as suboptimal and 30 lesions (36%) as poor. The factors associated with optimal image quality were distance closer to the fovea (OR 0.76, p<0.001), posterior pole location (OR 3.87, p=0.05), lower ultrasonography thickness (OR 0.44, p=0.04), lighter lesion pigmentation (OR 0.12, p=0.003) and smaller lesion diameter (OR 0.73, p<0.001). In the multivariable analysis, closer distance to the fovea (OR 0.81, p=0.005), lighter lesion pigmentation (OR 0.11, p=0.01) and smaller lesion diameter (OR 0.76, p=0.006) remained statistically significant. CONCLUSION: SS-OCT is useful in imaging most choroidal melanocytic lesions. Image quality is best when the choroidal lesion is closer to the fovea, has a smaller diameter and a lighter choroidal pigmentation.


Assuntos
Doenças da Coroide , Tomografia de Coerência Óptica , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças da Coroide/diagnóstico por imagem , Doenças da Coroide/patologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/normas , Adulto Jovem
16.
J Fr Ophtalmol ; 41(9): 857-861, 2018 Nov.
Artigo em Francês | MEDLINE | ID: mdl-30348597

RESUMO

PURPOSE: To update the recommendations of the France Macula Federation for the diagnosis of wet age-related macular degeneration (AMD). METHODS: Analysis of literature and expert opinion. RESULTS: The FMF recommends diagnosing wet AMD by combining the results of fundus examination (or color or monochromatic fundus photographs), optical coherence tomography (OCT) showing exudative signs, and morphological visualization of the neovascular membrane, which may be obtained non-invasively (OCT-angiography) or invasively (fluorescein and/or indocyanine green angiography). Under optimal conditions in which all these tools are available, the FMF recommends using non-invasive methods as first-line tools and resorting to dye angiography if diagnostic doubt remains. CONCLUSION: As observed in other fields of medical imaging, non-invasive methods are preferred to invasive methods for the diagnosis of wet AMD, while the latter are reserved for more difficult cases.


Assuntos
Técnicas de Diagnóstico Oftalmológico/normas , Degeneração Macular Exsudativa/diagnóstico , Prova Pericial , Angiofluoresceinografia/métodos , Angiofluoresceinografia/normas , França , Humanos , Macula Lutea/diagnóstico por imagem , Macula Lutea/patologia , Oftalmologia/organização & administração , Oftalmologia/normas , Sociedades Médicas/normas , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/normas
17.
Ophthalmic Surg Lasers Imaging Retina ; 49(8): 603-610, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-30114305

RESUMO

BACKGROUND AND OBJECTIVE: To illustrate how optical coherence tomography (OCT) angiography (OCTA) can be misinterpreted if not evaluated along with structural en face OCT to analyze the signal intensity. PATIENTS AND METHODS: Patients with different macular diseases associated with suspicious flow impairment in the choriocapillaris were recruited to be imaged on the RTVue XR Avanti device (Optovue, Fremont, CA) with the Angio Retina mode. En face OCT angiograms, structural en face OCT, and corresponding OCT B-scans with flow signal overlaid were compared to evaluate the correspondence of signal strength to areas of flow reduction in the choriocapillaris. RESULTS: Six eyes from six patients were enrolled. Macular lesions evaluated in this study included acute central serous chorioretinopathy, paracentral acute middle maculopathy, age-related macular degeneration, adult-onset foveomacular vitelliform dystrophy, and branch retinal vein occlusion. In all cases, areas of suspicious flow decrement in the choriocapillaris corresponded to hyporeflective areas in the intensity en face OCT. Thus, a precise confirmation of choriocapillaris flow impairment was not possible. CONCLUSION: It is essential to be aware of the importance of analyzing the structural image alongside with the flow image to interpret flow impairment. This is more important in subretinal pigment epithelial structures such as choriocapillaris and choroid. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:603-610.].


Assuntos
Corioide/patologia , Angiofluoresceinografia/normas , Doenças Retinianas/diagnóstico por imagem , Tomografia de Coerência Óptica/normas , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Angiofluoresceinografia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica/métodos
18.
Am J Ophthalmol ; 192: 77-83, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29753852

RESUMO

PURPOSE: To determine sensitivity and specificity of polypoidal choroidal vasculopathy (PCV) diagnosis using color fundus photography (CFP), optical coherence tomography (OCT), and fundus fluorescein angiography (FFA) without indocyanine green angiography (ICGA). DESIGN: Validity analysis. METHODS: Treatment-naïve eyes with serous/serosanguinous maculopathy undergoing CFP, OCT, FFA, and ICGA imaging before treatment at a university hospital in Thailand (January 1, 2013 to June 30, 2015) were identified. Images of each subject were categorized into 4 sets (set A: CFP; set B: CFP+OCT; set C: CFP+FFA; set D: CFP+OCT+FFA). Six graders, 3 from Thailand (PCV endemic area) and 3 from the United States (nonendemic area), individually reviewed each set (without ICGA), and determined if the presumed diagnosis was PCV. In parallel, 2 other graders confirmed if each case had PCV or not using EVEREST criteria (including ICGA). Sensitivity and specificity of a PCV diagnosis with each set (without ICGA) were analyzed compared with diagnoses including ICGA. RESULTS: Of 119 study eyes (113 subjects, 57% male, mean age ± SD 59.9 ± 13.8 years), definite PCV diagnosis was 40.3%. Sensitivity of sets A, B, C, D: 0.63 (95% confidence interval [CI]: 0.47-0.76), 0.83 (95% CI: 0.69-0.92), 0.54 (95% CI: 0.39-0.68), 0.67 (95% CI: 0.51-0.79); specificities: 0.93 (95% CI: 0.84-0.97), 0.83 (95% CI: 0.72-0.91), 0.97 (95% CI: 0.89-0.99), 0.92 (95% CI: 0.82-0.97); accuracies: 0.81 (95% CI: 0.73-0.88), 0.83 (95% CI: 0.76-0.90), 0.79 (95% CI: 0.73-0.87), 0.82 (95% CI: 0.74-0.88). Discrepancies between Thai and US graders existed through sets A, C, and D. CONCLUSIONS: These data suggest that without ICGA, fundus photography combined with OCT provides high sensitivity and high specificity to diagnose PCV; adding FFA does not improve accuracy.


Assuntos
Neovascularização de Coroide/diagnóstico , Angiofluoresceinografia/normas , Fundo de Olho , Fotografação/normas , Pólipos/diagnóstico , Tomografia de Coerência Óptica/normas , Adulto , Idoso , Povo Asiático/etnologia , Neovascularização de Coroide/etnologia , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pólipos/etnologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tailândia/epidemiologia
19.
Invest Ophthalmol Vis Sci ; 59(3): 1652-1658, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-29625491

RESUMO

Purpose: To map the corneal epithelium using a map measuring 9 mm in diameter and view the effects of age, sex, and axial length. Additionally, we wanted to demonstrate the reproducibility of this technique. Methods: We calculated the epithelial thickness in 220 individuals using an SD-OCT machine with the newly released commercially available algorithm. We included normal eyes with refractive errors between +5 and -6 diopters (D). We excluded patients with an intraocular pressure of >22 mm Hg, history of cataract, previous ocular surgery, or disease and those with corneal pathology. Additionally, we excluded patients with evidence of systemic disease or pregnancy. Lastly, reproducibility was measured in 50 individuals. Results: We found the center of the corneal epithelium to be thicker than the peripheral in all zones except the nasal (P = 0.124). The superior quadrant was found to be the thinnest while the inferior was the thickest. Males had a thicker epithelium in all locations except the superior outer section (P = 0.123). Three zones had a weak correlation with age: outer superior (P = 0.039, R = -0.152); outer temporal (P = 0.042, R = -0.150); and outer superior temporal (P = 0.011, R = -0.187). There was no significant relationship with the axial length. We found good to excellent reproducibility when using this technique in the central as well as the peripheral cornea. Conclusions: We provide a comprehensive study in healthy, normal eyes using a novel algorithm to map the corneal epithelium with a wide diameter. This study can be used as a reference for future research.


Assuntos
Epitélio Corneano/anatomia & histologia , Tomografia de Coerência Óptica/métodos , Adulto , Fatores Etários , Idoso , Comprimento Axial do Olho/fisiologia , Estudos Transversais , Epitélio Corneano/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores Sexuais , Tomografia de Coerência Óptica/normas , Adulto Jovem
20.
Arq. bras. oftalmol ; 81(1): 3-6, Jan.-Feb. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888182

RESUMO

ABSTRACT Purpose: To (a) determine the normative values for optical coherence tomography (OCT) parameters such as central macular thickness, retinal nerve fiber layer thickness, and choroidal thickness in healthy children; (b) investigate the relationships of these parameters with axial length, central corneal thickness, refractive errors, and intraocular pressure; and (c) determine interexaminer agreement for choroidal thickness measurements. Methods: In this cross-sectional study, 120 healthy children aged 8-15 years underwent detailed ophthalmological examination and OCT measurements. Choroidal thickness was measured at three separate locations by two independent examiners. Results: The mean global retinal nerve fiber layer thickness was 98.75 ± 9.45 μm (79.0-121.0). The mean central macular thickness was 232.29 ± 29.37 μm (190.0-376.0). The mean subfoveal choroidal thickness obtained by examiner 1 was 344.38 ± 68.83 μm and that obtained by examiner 2 was 344.04 ± 68.92 μm. Interexaminer agreement was between 99.6%-99.8% for choroidal thickness at three separate locations. Central macular thickness increased with axial length (r=0.245, p=0.007). Choroidal thickness increased with age (r=0.291, p=0.001) and decreased with axial length (r=-0.191, p=0.037). Global retinal nerve fiber layer thickness decreased with axial length (r=-0.247, p=0.007) and increased with central corneal thickness (r=0.208, p=0.022). Global retinal nerve fiber layer thickness positively correlated with choroidal thickness (r=0.354, p<0.001). Global retinal nerve fiber layer thickness (r=0.223, p=0.014) and choroidal thickness (r=0.272, p=0.003) increased with the spherical equivalent (D). Conclusions: Optical coherence tomography parameters showed a wide range of variability in children. Retinal nerve fiber layer thickness, central macular thickness, and choroidal thickness were found to be either inter-related or correlated with age, central corneal thickness, axial length, and refractive errors. Furthermore, manual measurements of choroidal thickness showed high interexaminer agreement. Because normative values for optical coherence tomography parameters differed in children, the measurements should be interpreted according to an age-appropriate database.


RESUMO Objetivo: Determinar valores normativos para parâmetros de tomografia de coerência óptica consistindo em espessura macular central, espessura da camada de fibra nervosa da retina e espessura coroidal em crianças saudáveis, para investigar suas relações com o comprimento axial, espessura corneana central, erros refractivos e pressão intraocular e determinar a concordância interexaminador para medidas de espessura coroidal. Métodos: um total de 120 crianças saudáveis com idade entre 8 e 15 anos foram submetidas a exame oftalmológico detalhado e a medições de tomografia de coerência óptica em uma configuração de estudo transversal. A espessura coroide foi medida por dois examinadores independentes em 3 pontos distintos. Resultados: A espessura global media da camada de fibra nervosa da retina foi de 98.75 ± 9.45 μm (79.0-121.0). A espessura macular central media foi de 232.29 ± 29.37 μm (190.0-376.0). A espessura coroidea subfoveal media foi de 344.38 ± 68.83 μm medida pelo examinador 1 e 344.04 ± 68.92 μm medida pelo examinador 2. A concordância foi entre 99.6-99.8% para a espessura coroidal em 3 pontos distintos. Verificou-se que a espessura macular central aumentava com o comprimento axial (r=0.245, p=0.007). A espessura da coroide aumentou com a idade (r=0.291, p=0.001) e diminuiu com o comprimento axial (r=-0.191, p=0.037). A espessura global da camada de fibras nervosas da retina diminuiu com o comprimento axial (r=-0.247, p=0.007) e aumenta com a espessura central da córnea (r=0.208, p=0.022). A espessura global da camada de fibras nervosas da retina foi correlacionada positivamente com a espessura coroidal (r=0.354, p<0.001). A espessura global da camada de fibras nervosas da retina (r=0.223, p=0.014) e a espessura coroide (r=0.272, p=0.003) aumentaram com o equivalente esférico (D). Conclusões: os parâmetros de tomografia de coerência óptica parecem mostrar uma ampla gama de variabilidade em crianças. A espessura da camada de fibra nervosa da retina, a espessura macular central, a espessura coroidea estão inter-relacionadas ou correlacionadas com a idade, espessura corneana central, comprimento axial e erros refractivos. Além disso, as medidas manuais da espessura coroidea apresentaram alta concordância entre examinadores. Deve-se ter em mente que os valores normativos dos parâmetros da tomografia de coerência óptica diferem em crianças, portanto, as medidas devem ser interpretadas de acordo com uma determinada base de dados apropriada para idade.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Retina/anatomia & histologia , Corioide/anatomia & histologia , Tomografia de Coerência Óptica/normas , Tamanho do Órgão , Padrões de Referência , Valores de Referência , Erros de Refração/patologia , Variações Dependentes do Observador , Estudos Transversais , Estatísticas não Paramétricas , Paquimetria Corneana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA