Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Florianópolis; s.n; 24 jul. 2020. 8 p.
Não convencional em Português | SES-SC, Coleciona SUS, CONASS, LILACS | ID: biblio-1119470

RESUMO

Adoção de medidas preventivas e estabelece recomendações para ventilação mecânica, e utilização de ventiladores pulmonares no SAMU. No serviço há modelos diversos de ventiladores pulmonares, para utilização nos pacientes que necessitam de suporte ventilatório durante os atendimentos e/ou transportes, inclusive pacientes suspeitos ou confirmados para COVID-19.


Assuntos
Humanos , Masculino , Feminino , Pneumonia Viral/terapia , Respiração Artificial/normas , Ventiladores Mecânicos , Infecções por Coronavirus/terapia , Serviços Médicos de Emergência , Utilização de Equipamentos e Suprimentos/normas
2.
J Glaucoma ; 28(6): 507-511, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30950966

RESUMO

PRECIS: We checked 190 tonometers every month and repaired faulty ones. Calibration error (CE) frequency reduced from 23% to 0.6% at 1 year. Tonometers needing one or >1 CE repair differed in survival but not in age. PURPOSE: The purpose of this study was to report the outcomes of a comprehensive program to maintain calibration status of the Goldmann applanation tonometer. METHODS: This prospective cohort study was carried out at 2 tertiary eye care referral centers. We included 190 slit-lamp mounted Goldmann applanation tonometers (Model AT 900 C/M). Health care providers (error checking and reporting) and clinical engineers (maintenance) participated. The team carried out CE check once a month, and repair of faulty tonometers, if any, within 24 hours. Failure of tonometer was defined as development of unacceptable CE beyond the third repair. The main outcome measures were the frequency of CE and survival function of the tonometer over 1 year. RESULTS: The median age of the tonometers was 10.7 (range, 0.2 to 25.1) years. The total number of repairs was 86. The proportion (95% confidence interval) of faulty tonometers reduced from 23.1% (17.7, 29.6) in the first month to 0.6% (0.1, 3.3) at 1 year (P<0.01). The median age of the tonometer did not differ between those needing (n=63, 9.4 y) and not needing (n=127, 10.7 y; P=0.24) repair. All tonometers requiring 1 CE repair (n=49, 25.7%) survived until 1 year. The survival of tonometers requiring >1 CE repair (n=14, 7.3%) was 40% at 1 year. CONCLUSIONS: Our in-house program maintained 92.6% tonometers error free. Number of repairs rather than age determined the need for replacement/sending back the tonometer to the manufacturer. Our simple and easy to follow maintenance program has the potential for wide application.


Assuntos
Utilização de Equipamentos e Suprimentos/organização & administração , Centros de Atenção Terciária/organização & administração , Tonometria Ocular/instrumentação , Tonometria Ocular/normas , Calibragem , Estudos de Coortes , Desenho de Equipamento , Falha de Equipamento/estatística & dados numéricos , Utilização de Equipamentos e Suprimentos/normas , Utilização de Equipamentos e Suprimentos/estatística & dados numéricos , Humanos , Pressão Intraocular , Manutenção/métodos , Manutenção/organização & administração , Oftalmologia/organização & administração , Oftalmologia/normas , Oftalmologia/estatística & dados numéricos , Avaliação de Resultados em Cuidados de Saúde , Avaliação de Programas e Projetos de Saúde , Estudos Prospectivos , Reprodutibilidade dos Testes , Centros de Atenção Terciária/normas , Centros de Atenção Terciária/estatística & dados numéricos , Tonometria Ocular/estatística & dados numéricos
4.
J Natl Compr Canc Netw ; 16(9): 1084-1091, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30181420

RESUMO

Background: The NCCN Clinical Practice Guidelines in Oncology (NCCN Guidelines) have directed the care of patients with cancer for >20 years. Payers are implementing guideline-based pathway programs that restrict reimbursement for non-guideline-based care to control costs, yet evidence regarding impact of guidelines on outcomes, including mortality, Medicare costs, and healthcare utilization, is limited. Patients and Methods: This analysis evaluated concordance of first treatment with NCCN Guidelines for women with de novo stage IV metastatic breast cancer (MBC) included within the SEER-Medicare linked database and diagnosed between 2007 and 2013. Cox proportional hazards models were used to evaluate the association between mortality and guideline concordance. Linear mixed-effects and generalized linear models were used to evaluate total cost to Medicare and rates of healthcare utilization by concordance status. Results: We found that 19% of patients (188/988) with de novo MBC received nonconcordant treatment. Patients receiving nonconcordant treatment were more likely to be younger and have hormone receptor-negative and HER2-positive MBC. The most common category of nonconcordant treatment was use of adjuvant regimens in the metastatic setting (40%). Adjusted mortality risk was similar for patients receiving concordant and nonconcordant treatments (hazard ratio [HR], 0.85; 95% confidence limit [CL], 0.69, 1.05). When considering category of nonconcordance, patients receiving adjuvant regimens in the metastatic setting had a decreased risk of mortality (HR, 0.60; 95% CL, 0.43, 0.84). Nonconcordant treatments were associated with $1,867 higher average Medicare costs per month compared with concordant treatments (95% CL, $918, $2,817). Single-agent HER2-targeted therapy was the highest costing category of nonconcordance at $3,008 (95% CL, $1,014, $5,001). Healthcare utilization rates were similar for patients receiving concordant and nonconcordant treatments. Conclusions: Despite a lack of survival benefit, concordant care was associated with lower costs, suggesting potential benefit to increasing standardization of care. These findings may influence policy decisions regarding implementation of pathway programs as health systems transition to value-based models.


Assuntos
Neoplasias da Mama/terapia , Fidelidade a Diretrizes/estatística & dados numéricos , Custos de Cuidados de Saúde/normas , Medicare/estatística & dados numéricos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Protocolos de Quimioterapia Combinada Antineoplásica/economia , Protocolos de Quimioterapia Combinada Antineoplásica/normas , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/economia , Neoplasias da Mama/mortalidade , Quimioterapia Adjuvante/economia , Quimioterapia Adjuvante/normas , Quimioterapia Adjuvante/estatística & dados numéricos , Utilização de Equipamentos e Suprimentos/economia , Utilização de Equipamentos e Suprimentos/normas , Utilização de Equipamentos e Suprimentos/estatística & dados numéricos , Feminino , Fidelidade a Diretrizes/economia , Custos de Cuidados de Saúde/estatística & dados numéricos , Recursos em Saúde/economia , Recursos em Saúde/estatística & dados numéricos , Humanos , Mastectomia/economia , Mastectomia/normas , Oncologia/normas , Medicare/economia , Pessoa de Meia-Idade , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Guias de Prática Clínica como Assunto , Programa de SEER/estatística & dados numéricos , Sociedades Médicas/normas , Análise de Sobrevida , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA