Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.673
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Langenbecks Arch Surg ; 409(1): 147, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38695955

RESUMO

PURPOSE: To investigate the accuracy of laser speckle flowgraphy (LSFG), a noninvasive method for the quantitative evaluation of blood flow using mean blur rate (MBR) as a blood flow parameter in the assessment of bowel blood perfusion compared to indocyanine green fluorescence angiography (ICG-FA). METHODS: We enrolled 46 patients who underwent left-sided colorectal surgery. LSFG and ICG-FA were applied to assess blood bowel perfusion, with MBR and luminance as parameters, respectively. In both measurement methods, the position where the parameter suddenly decreased was defined as the blood flow boundary line. Subsequently, the blood flow boundaries created after processing the blood vessels flowing into the intestinal tract were determined using LSFG and ICG-FA, and concordance between the two was examined. Blood flow boundaries were visually identified using color tone changes on a color map created based on MBR in LSFG and using differences in luminance in ICG-FA. The distances between the transection line and blood flow boundaries determined using each method were compared. RESULTS: The location of blood flow boundaries matched in 65% (30/46) of cases. Although locations differed in the remaining 35% (16/46), all were located on the anal side near the transection line, and the difference was not clinically significant. The average distances between the transection line and blood flow boundary were 2.76 (SD = 3.25) and 3.71 (SD = 4.26) mm, respectively. There was no statistically significant difference between the two groups (p = 0.38). CONCLUSION: LSFG was shown to have comparable accuracy to ICG-FA, and may be useful for evaluating bowel perfusion.


Assuntos
Corantes , Angiofluoresceinografia , Verde de Indocianina , Humanos , Feminino , Angiofluoresceinografia/métodos , Masculino , Idoso , Pessoa de Meia-Idade , Imagem de Contraste de Manchas a Laser , Idoso de 80 Anos ou mais , Fluxo Sanguíneo Regional/fisiologia , Adulto , Intestinos/irrigação sanguínea , Velocidade do Fluxo Sanguíneo/fisiologia , Neoplasias Colorretais/cirurgia
2.
Comput Methods Programs Biomed ; 249: 108146, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38593514

RESUMO

BACKGROUND AND OBJECTIVE: In the current work, we present a descriptive fluid-structure interaction computational study of the end-to-side radio-cephalic arteriovenous fistula. This allows us to account for the different thicknesses and elastic properties of the radial artery and cephalic vein. METHODS: The core of the work consists in simulating different arteriovenous fistula configurations obtained by virtually varying the anastomosis angle, i.e. the angle between the end of the cephalic vein and the side of the radial artery. Since the aim of the work is to understand the blood dynamics in the very first days after the surgical intervention, the radial artery is considered stiffer and thicker than the cephalic vein. RESULTS: Our results demonstrate that both the diameter of the cephalic vein and the anastomosis angle play a crucial role to obtain a blood dynamics without re-circulation regions that could prevent fistula failure. CONCLUSIONS: When an anastomosis angle close to the perpendicular direction with respect to the radial artery is combined with a large diameter of the cephalic vein, the recirculation regions and the low Wall Shear Stress (WSS) zones are reduced. Conversely, from a structural point of view, a low anastomosis angle with a large diameter of the cephalic vein reduces the mechanical stress acting on the vessel walls.


Assuntos
Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Humanos , Derivação Arteriovenosa Cirúrgica/métodos , Velocidade do Fluxo Sanguíneo , Artéria Radial , Diálise Renal , Resultado do Tratamento
3.
Eur Rev Med Pharmacol Sci ; 28(7): 2848-2859, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38639524

RESUMO

OBJECTIVE: Transit-time flow measurement (TTFM) represents a valid tool in the assessment of the quality of the anastomosis during coronary artery bypass graft (CABG). Nevertheless, a high variability limits its standardized use, lacking univocally accepted cut-off flow values. Our study analyzes TTFM data collected from a study population that underwent off-pump CABG (OP-CABG), with the aim to differentiate into subgroups according to the presence of diabetes mellitus. PATIENTS AND METHODS: Patients referred to the Cardiovascular Unit of S. Michele Hospital (Caserta, Italy) for coronary artery disease (CAD) and underwent OP-CABG between January 2015 and December 2019 were enrolled, and intraoperative TTFMs data were recruited and evaluated. Mean graft flow (MGF) and pulsatility index (PI) values were collected and analyzed. RESULTS: The study population was composed of 342 patients who underwent OP-CABG with TTFM data regarding 824 grafts. Diabetic patients shared a higher cardiovascular risk profile. The TTFM assessment showed better results for the use of the arterial grafts in diabetic patients, especially for those insulin-dependent; conversely, venous grafts showed worse data with lower MGF and higher PI values. In particular, the anastomoses of the saphenous vein graft with marginal obtuse (MO) coronary artery showed worse MGF results in the insulin-dependent rather than normoglycemic subgroup (28.66 vs. 38.44, p=0.003). CONCLUSIONS: Diabetic patients, especially in the insulin-dependent subgroups, have demonstrated lower MGF and higher PI values collected from venous anastomoses with, conversely, inverse results from the arterial one. These results might be correlated to an altered biological adaptability caused by the effects of the diabetic endocrine disorder.


Assuntos
Vasos Coronários , Diabetes Mellitus , Humanos , Grau de Desobstrução Vascular , Velocidade do Fluxo Sanguíneo , Insulina
4.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38637325

RESUMO

AIMS: Left atrial appendage electrical isolation (LAAEI) has demonstrated a significant enhancement in the success rate of atrial fibrillation (AF) ablation. Nevertheless, concerns persist about the safety of LAAEI, particularly regarding alterations in left atrial appendage (LAA) flow velocity and the potential risks of thrombus. This study aimed to assess the efficacy and safety of LAAEI, investigating changes in LAA flow velocity in canines. METHODS AND RESULTS: The study comprised a total of 10 canines. The LAAEI procedure used by a 23 mm cryoballoon of the second generation was conducted at least 180 s. Intracardiac ultrasonography (ICE) was employed to quantify the velocity flow of the LAA both prior to and following LAAEI. Following a 3-month period, subsequent evaluations were performed to assess the LAA velocity flow and the potential reconnection. Histopathological examination was conducted. Left atrial appendage electrical isolation was effectively accomplished in all canines, resulting in a 100% acute success rate (10/10). The flow velocity in the LAA showed a notable reduction during LAAEI as compared with the values before the ablation procedure (53.12 ± 5.89 vs. 42.01 ± 9.22 cm/s, P = 0.007). After the follow-up, reconnection was observed in four canines, leading to a success rate of LAAEI of 60% (6/10). The flow velocity in the LAA was consistently lower (53.12 ± 5.89 vs. 44.33 ± 10.49 cm/s, P = 0.006), and no blood clot development was observed. The histopathological study indicated that there was consistent and complete injury to the LAA, affecting all layers of its wall. The injured tissue was subsequently replaced by fibrous tissue. CONCLUSION: The feasibility of using cryoballoon ablation for LAAEI was confirmed in canines, leading to a significant reduction of LAA flow velocity after ablation. Some restoration of LAA flow velocity after ablation may be linked to the passive movement of the LAA and potential reconnecting. However, this conclusion is limited to animal study; more clinical data are needed to further illustrate the safety and accessibility of LAAEI in humans.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Criocirurgia , Cães , Animais , Apêndice Atrial/cirurgia , Criocirurgia/métodos , Criocirurgia/efeitos adversos , Criocirurgia/instrumentação , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Desenho de Equipamento , Velocidade do Fluxo Sanguíneo , Resultado do Tratamento , Masculino
5.
J Cardiothorac Surg ; 19(1): 224, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627771

RESUMO

Coronary artery bypass grafting (CABG) is one of the foundations of treatment for coronary artery disease. While it has improved substantially since its inception more than 50 years ago, including a rising use of multiple arterial grafting, intraoperative quality assessment is yet to be disseminated as an integral part of the procedure. Herein we review the fundamentals of intraoperative quality assessment in CABG using transient time flow measurement (TTFM) with a focus on its use in arterial grafting.


Assuntos
Doença da Artéria Coronariana , Artéria Torácica Interna , Humanos , Angiografia Coronária , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Artéria Torácica Interna/transplante , Grau de Desobstrução Vascular , Velocidade do Fluxo Sanguíneo
6.
Cardiovasc Intervent Radiol ; 47(5): 533-542, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38565717

RESUMO

PURPOSE: In arterial disease, the presence of two or more serial stenotic lesions is common. For mild lesions, it is difficult to predict whether their combined effect is hemodynamically significant. This study assessed the hemodynamic significance of idealized serial stenotic lesions by simulating their hemodynamic interaction in a computational flow model. MATERIALS AND METHODS: Flow was simulated with SimVascular software in 34 serial lesions, using moderate (15 mL/s) and high (30 mL/s) flow rates. Combinations of one concentric and two eccentric lesions, all 50% area reduction, were designed with variations in interstenotic distance and in relative direction of eccentricity. Fluid and fluid-structure simulations were performed to quantify the combined pressure gradient. RESULTS: At a moderate flow rate, the combined pressure gradient of two lesions ranged from 3.8 to 7.7 mmHg, which increased to a range of 12.5-24.3 mmHg for a high flow rate. Eccentricity caused an up to two-fold increase in pressure gradient relative to concentric lesions. At a high flow rate, the combined pressure gradient for serial eccentric lesions often exceeded the sum of the individual lesions. The relative direction of eccentricity altered the pressure gradient by 15-25%. The impact of flow pulsatility and wall deformability was minor. CONCLUSION: This flow simulation study revealed that lesion eccentricity is an adverse factor in the hemodynamic significance of isolated stenotic lesions and in serial stenotic lesions. Two 50% lesions that are individually non-significant can combine more often than thought to hemodynamic significance in hyperemic conditions.


Assuntos
Simulação por Computador , Hemodinâmica , Humanos , Hemodinâmica/fisiologia , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico por imagem
7.
Jpn J Ophthalmol ; 68(3): 211-215, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38609716

RESUMO

PURPOSE: To investigate the association between the arm-to-choroidal circulation time (ACT) on indocyanine green angiography (IA) and clinical profile in patients with polypoidal choroidal vasculopathy (PCV). STUDY DESIGN: Single-center retrospective study. METHODS: We included 38 eyes of 38 patients with PCV diagnosed using multimodal imaging and did not undergo previous treatment. All patients were treated with monthly aflibercept injections for 3 months and treat-and-extend regimens for the subsequent 12 months. Posterior vortex vein ACT was assessed on the first visit using Heidelberg IA. The patients were divided into two groups: ACT ≥20 s (L group; eight eyes) and ACT <20 s (S group; 30 eyes). The clinical profiles before and after treatment were analyzed to assess associations with ACT. RESULTS: The mean ACT was 16.39±3.3 s (L group: 21.25±1.49 s, women:men=2:6, mean age: 77.3±6.5 years; S group: 15.10±2.17 s, women:men=7:23, mean age: 75.5±6.9 years). No significant difference was observed in the mean subfoveal choroidal thickness between the L and the S groups (176±75 µm vs. 230±79 µm, P=0.10). However, there were significant differences between the L and S groups in retinal fluid accumulation and hemorrhage recurrence (eight/eight eyes, 100% vs. 13/30 eyes, 43%, P<0.001), mean aflibercept injections (8.8±1.6 vs. 7.0±1.6, P<0.01) during the 12-month period, and the number of polypoidal lesions (1.8±0.7 vs. 1.3±0.5, P<0.05). CONCLUSION: Patients with PCV and ACT >20 s are more likely to experience exudative change recurrence in the retina during treatment because they have more polypoidal lesions.


Assuntos
Corioide , Angiofluoresceinografia , Fundo de Olho , Injeções Intravítreas , Pólipos , Receptores de Fatores de Crescimento do Endotélio Vascular , Proteínas Recombinantes de Fusão , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Feminino , Masculino , Estudos Retrospectivos , Corioide/irrigação sanguínea , Corioide/diagnóstico por imagem , Idoso , Angiofluoresceinografia/métodos , Tomografia de Coerência Óptica/métodos , Pólipos/diagnóstico , Pólipos/tratamento farmacológico , Pólipos/fisiopatologia , Receptores de Fatores de Crescimento do Endotélio Vascular/uso terapêutico , Receptores de Fatores de Crescimento do Endotélio Vascular/administração & dosagem , Proteínas Recombinantes de Fusão/administração & dosagem , Proteínas Recombinantes de Fusão/uso terapêutico , Verde de Indocianina/administração & dosagem , Seguimentos , Neovascularização de Coroide/tratamento farmacológico , Neovascularização de Coroide/diagnóstico , Neovascularização de Coroide/fisiopatologia , Corantes/administração & dosagem , Idoso de 80 Anos ou mais , Doenças da Coroide/diagnóstico , Doenças da Coroide/tratamento farmacológico , Doenças da Coroide/fisiopatologia , Inibidores da Angiogênese/administração & dosagem , Inibidores da Angiogênese/uso terapêutico , Fluxo Sanguíneo Regional/fisiologia , Imagem Multimodal , Velocidade do Fluxo Sanguíneo/fisiologia , Vasculopatia Polipoidal da Coroide
8.
Eur Radiol Exp ; 8(1): 45, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38472565

RESUMO

BACKGROUND: Phase-contrast magnetic resonance imaging (PC-MRI) quantifies blood flow and velocity noninvasively. Challenges arise in neurovascular disorders due to small vessels. We evaluated the impact of voxel size, number of signal averages (NSA), and velocity encoding (VENC) on PC-MRI measurement accuracy and precision in a small-lumen vessel phantom. METHODS: We constructed an in vitro model with a constant flow rate using a 2.2-mm inner diameter plastic tube. A reservoir with a weight scale and timer was used as standard reference. Gradient-echo T1 weighted PC-MRI sequence was performed on a 3-T scanner with varying voxel size (2.5, 5.0, 7.5 mm3), NSA (1, 2, 3), and VENC (200, 300, 400 cm/s). We repeated measurements nine times per setting, calculating mean flow rate, maximum velocity, and least detectable difference (LDD). RESULTS: PC-MRI flow measurements were higher than standard reference values (mean ranging from 7.3 to 9.5 mL/s compared with 6.6 mL/s). Decreased voxel size improved accuracy, reducing flow rate measurements from 9.5 to 7.3 mL/s. The LDD for flow rate and velocity varied between 1 and 5%. The LDD for flow rate decreased with increased voxel size and NSA (p = 0.033 and 0.042). The LDD for velocity decreased with increased voxel size (p < 10-16). No change was observed when VENC varied. CONCLUSIONS: PC-MRI overestimated flow. However, it has high precision in a small-vessel phantom with constant flow rate. Improved accuracy was obtained with increasing spatial resolution (smaller voxels). Improved precision was obtained with increasing signal-to-noise ratio (larger voxels and/or higher NSA). RELEVANCE STATEMENT: Phase-contrast MRI is clinically used in large vessels. To further investigate the possibility of using phase-contrast MRI for smaller intracranial vessels in neurovascular disorders, we need to understand how acquisition parameters affect phase-contrast MRI-measured flow rate and velocity in small vessels. KEY POINTS: • PC-MRI measures flow and velocity in a small lumen phantom with high precision but overestimates flow rate. • The precision of PC-MRI measurements matches the precision of standard reference for flow rate measurements. • Optimizing PC-MRI settings can enhance accuracy and precision in flow rate and velocity measurements.


Assuntos
Imageamento por Ressonância Magnética , Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento por Ressonância Magnética/métodos , Razão Sinal-Ruído , Imagens de Fantasmas , Reprodutibilidade dos Testes
9.
Magn Reson Imaging ; 109: 67-73, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38484947

RESUMO

PURPOSE: To investigate longitudinal thoracic aorta injury using 3-dimensional phase-contrast magnetic resonance imaging (4D flow MRI) parameters and to evaluate their value for predicting the subsequent main adverse cardiovascular events (MACEs) in breast cancer patients receiving anthracyclines. METHODS: Between July 2020 and July 2021, eighty-eight female participants with breast cancer scheduled to receive anthracyclines with or without trastuzumab prospectively enrolled. Each subjects underwent 4D flow MRI at baseline, 3 and 6 months in relation to baseline. The diameter, peak velocity (Vpeak), wall shear stress (WSS), pulse wave velocity (PWV), energy loss (EL) and pressure gradient (PG) of thoracic aorta were measured. The association between these parameters and subsequent MACEs was performed by Cox proportional hazard models. RESULTS: Ten participants had subsequently MACEs. The Vpeak and PG gradually decreased and the WSS, PWV and EL progressively increased at 3 and 6 months compared with baseline. Adjusted multivariable analysis showed that the WSS of the proximal, mid- and distal ascending aorta [HR, 1.314 (95% confidence interval (CI): 1.003, 1.898)], [HR, 1.320 (95% CI: 1.002, 1.801)] and [HR, 1.322 (95% CI: 1.001, 1.805)] and PWV of ascending aorta [HR, 2.223 (95% CI: 1.010, 4.653)] at 3 months were associated with subsequent MACEs. Combined WSS and PWV of ascending aorta at 3 months yielded the highest AUC (0.912) for predicting subsequent MACEs. CONCLUSION: Combined WSS and PWV of ascending aorta at 3 months is helpful for predicting the subsequent MACEs in breast cancer patients treated by anthracyclines.


Assuntos
Neoplasias da Mama , Doenças Cardiovasculares , Humanos , Feminino , Aorta Torácica/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Análise de Onda de Pulso , Antraciclinas/efeitos adversos , Estudos Longitudinais , Imageamento por Ressonância Magnética/métodos , Doenças Cardiovasculares/patologia , Velocidade do Fluxo Sanguíneo , Hemodinâmica , Estresse Mecânico
10.
J Neuroimaging ; 34(3): 348-355, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38553906

RESUMO

BACKGROUND AND PURPOSE: Thresholds for abnormal transcranial Doppler cerebrovascular reactivity (CVR) studies are poorly understood, especially for patients with cerebrovascular disease. Using a real-world cohort with cerebral arterial stenosis, we sought to describe a clinically significant threshold for carbon dioxide reactivity (CO2R) and vasomotor range (VMR). METHODS: CVR studies were performed during conditions of breathing room air normally, breathing 8% carbon dioxide air mixture, and hyperventilation. The mean and standard deviation (SD) of CO2R and VMR were calculated for the unaffected side in patients with unilateral stenosis; a deviation of 2 SDs below the mean was chosen as the threshold for abnormal. Receiver operating characteristic (ROC) curves for both sides for patients with unilateral and bilateral stenosis were evaluated for sensitivity (Sn) and specificity (Sp). RESULTS: A total of 133 consecutive CVR studies were performed on 62 patients with stenosis with mean±SD age 55±16 years. Comorbidities included hypertension (60%), diabetes (15%), stroke (40%), and smoking (35%). In patients with unilateral stenosis, mean±SD CO2R for the unaffected side was 1.86±0.53%, defining abnormal CO2R as <0.80%. Mean±SD CO2R for the affected side was 1.27±0.90%. The CO2R threshold predicted abnormal acetazolamide single-photon emission computed tomography (SPECT) (Sn = .73, Sp = .79), CT/MRI perfusion abnormality (Sn = .42, Sp = .77), infarction on MRI (Sn = .45, Sp = .76), and pressure-dependent exam (Sn = .50, Sp = .76). For the unaffected side, mean±SD VMR was 39.5±15.8%, defining abnormal VMR as <7.9%. For the affected side, mean±SD VMR was 26.5±17.8%. The VMR threshold predicted abnormal acetazolamide SPECT (Sn = .46, Sp = .94), infarction on MRI (Sn = .27, Sp = .94), and pressure-dependent exam (Sn = .31, Sp = .90). CONCLUSIONS: In patients with multiple vascular risk factors, a reasonable threshold for clinically significant abnormal CO2R is <0.80% and VMR is <7.9%. Noninvasive CVR may aid in diagnosing and risk stratifying patients with stenosis.


Assuntos
Circulação Cerebrovascular , Sensibilidade e Especificidade , Ultrassonografia Doppler Transcraniana , Humanos , Ultrassonografia Doppler Transcraniana/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Transtornos Cerebrovasculares/diagnóstico por imagem , Transtornos Cerebrovasculares/fisiopatologia , Dióxido de Carbono , Reprodutibilidade dos Testes , Idoso , Velocidade do Fluxo Sanguíneo , Relevância Clínica
11.
Biomed Mater Eng ; 35(3): 237-248, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38461499

RESUMO

BACKGROUND: The incidence of arterial stenosis is increasing year by year. In order to better diagnose and treat arterial stenosis, numerical simulation technology has become a popular method. OBJECTIVE: A novel model is constructed to investigate the influence of microcirculation on the hemodynamics of artery bypass graft. METHODS: In this paper, a severely narrow artery bypass graft model is considered. The geometric shape includes a narrow artery tube and a bypass graft of the same diameter with a 45° suture angle. The fluid-structure interaction model is considered by finite element numerical calculation, and the flow is simulated with microcirculation as the outlet boundary condition. The changes of blood flow velocity, pressure and wall shear stress are analyzed. RESULTS: The results show that blood almost entirely flows into the graft tube and there is no recirculation area at the anastomosis. CONCLUSION: The artery bypass graft model considering microcirculation function could simulate the physiological characteristics of blood flow more reasonably, and it provide helps for clinicians to diagnose and treat arterial stenosis.


Assuntos
Simulação por Computador , Hemodinâmica , Microcirculação , Modelos Cardiovasculares , Humanos , Velocidade do Fluxo Sanguíneo , Ponte de Artéria Coronária/métodos , Estresse Mecânico , Análise de Elementos Finitos
12.
BMC Ophthalmol ; 24(1): 89, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38413884

RESUMO

BACKGROUND: To evaluate the changes in retrobulbar circulation after strabismus surgery and to assess the relationship of these changes with choroidal thickness (CT). METHODS: This prospective study included 26 eyes of 26 patients who underwent strabismus surgery and 15 eyes of 15 healthy individuals as control group. The patients who had single horizontal muscle surgery were included in Group 1 (n = 14); and those who had surgery on both horizontal muscles were included in Group 2 (n = 12). Peak systolic velocity (PSV), end-diastolic velocity (EDV), resistive index (RI) and pulsatility index (PI) of ophthalmic artery (OA), posterior ciliary artery (PCA), and central retinal artery (CRA) were measured using Color Doppler Ultrasonography. Subfoveal CT was measured via Optical Coherence Tomography. All measurements were obtained preoperatively, at 1st week and 1st month after surgery. RESULTS: There were no differences regarding preoperative blood flow velocity parameters among the groups. OA RI increased significantly at 1st week and 1st month after surgery in Group 1 and 2 (P = 0.029 and P = 0.045, respectively). There was a significant increase in PCA PSV at 1st week in Group 1 (P = 0.002). There was no difference between the mean preoperative and postoperative CT among the 3 groups. A negative correlation between the percentage changes of CT and CRA EDV was found in Group 2 (P = 0.011). CONCLUSION: Single and double horizontal rectus muscle surgery have a measurable effect on retrobulbar hemodynamics but these changes do not correlate with CT.


Assuntos
Artéria Retiniana , Estrabismo , Humanos , Estudos Prospectivos , Órbita , Hemodinâmica/fisiologia , Artéria Retiniana/diagnóstico por imagem , Artéria Oftálmica , Velocidade do Fluxo Sanguíneo/fisiologia , Corioide , Ultrassonografia Doppler em Cores/métodos , Estrabismo/cirurgia
14.
J Plast Reconstr Aesthet Surg ; 91: 111-118, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38412601

RESUMO

BACKGROUND: There is a lack of data regarding the baseline hemodynamic blood flow parameters of the wrist and digits. Therefore, we aimed to quantify the digital and radial artery blood flow parameters using ultrasound and assess the influence of patient characteristics on hemodynamics. METHODS: We analyzed ultrasonographic data from 25 patients (50 hands) between October 2019 and December 2021. Variables of interest included dimensions of the radial artery and index finger (IF) ulnar and radial digital arteries at the palmodigital crease and their corresponding flow parameters. We compared variables among men and women and patients with and without diabetes using Wilcoxon Rank Sum test. RESULTS: Our cohort consisted of 18 women (36 hands) and three participants with diabetes (six hands). The mean diameter of the IF radial digital artery was 7 mm, and that of the ulnar digital artery was 10 mm. The average peak systolic velocity for the radial digital artery was 21.31 cm/sec, and for the ulnar digital artery, it was 30.03 cm/sec. Comparing men and women, the only significant difference found was in the time-averaged mean velocity for the ulnar digital artery (men:5.66 cm/sec vs. women:9.68 cm/sec, P = 0.02) and volume of flow for the ulnar digital artery (men:10.87cc/min vs. women:18.58cc/min, P = 0.03). We found no differences in blood flow parameters comparing participants with and without diabetes. CONCLUSION: These data provide a baseline measurement of digital flow hemodynamics that can be used in future studies to model vascular flow after replantation.


Assuntos
Diabetes Mellitus , Artéria Ulnar , Masculino , Humanos , Feminino , Artéria Ulnar/diagnóstico por imagem , Hemodinâmica , Artéria Radial/diagnóstico por imagem , Punho , Velocidade do Fluxo Sanguíneo/fisiologia
15.
Am J Physiol Heart Circ Physiol ; 326(5): H1105-H1116, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38391313

RESUMO

Whether cerebral sympathetic-mediated vasomotor control can be modulated by local brain activity remains unknown. This study tested the hypothesis that the application or removal of a cognitive task during a cold pressor test (CPT) would attenuate and restore decreases in cerebrovascular conductance (CVC), respectively. Middle cerebral artery blood velocity (transcranial Doppler) and mean arterial pressure (finger photoplethysmography) were examined in healthy adults (n = 16; 8 females and 8 males) who completed a control CPT, followed by a CPT coupled with a cognitive task administered either 1) 30 s after the onset of the CPT and for the duration of the CPT or 2) at the onset of the CPT and terminated 30 s before the end of the CPT (condition order was counterbalanced). The major finding was that the CPT decreased the index of CVC, and such decreases were abolished when a cognitive task was completed concurrently and restored when the cognitive task was removed. As a secondary experiment, vasomotor interactions between sympathetic transduction pathways (α1-adrenergic and Y1-peptidergic) and compounds implicated in cerebral blood flow control [adenosine, and adenosine triphosphate (ATP)] were explored in isolated porcine cerebral arteries (wire myography). The data reveal α1-receptor agonism potentiated vasorelaxation modestly in response to adenosine, and preexposure to ATP attenuated contractile responses to α1-agonism. Overall, the data suggest a cognitive task attenuates decreases in CVC during sympathoexcitation, possibly related to an interaction between purinergic and α1-adrenergic signaling pathways.NEW & NOTEWORTHY The present study demonstrates that the cerebrovascular conductance index decreases during sympathoexcitation and this response can be positively and negatively modulated by the application or withdrawal of a nonexercise cognitive task. Furthermore, isolated vessel experiments reveal that cerebral α1-adrenergic agonism potentiates adenosine-mediated vasorelaxation and ATP attenuates α1-adrenergic-mediated vasocontraction.


Assuntos
Trifosfato de Adenosina , Simpatolíticos , Adulto , Masculino , Feminino , Humanos , Animais , Suínos , Velocidade do Fluxo Sanguíneo/fisiologia , Adrenérgicos , Adenosina/farmacologia , Circulação Cerebrovascular/fisiologia , Pressão Sanguínea/fisiologia , Temperatura Baixa
16.
J Biophotonics ; 17(3): e202300439, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38302735

RESUMO

Due to morphological characteristics, metastatic melanoma is a cancer for which vascularization is not a diagnostic criterion. Laser speckle contrast imaging (LSCI) and contrast enhanced ultrasound (CEUS) are two imaging techniques that will be explored in this study, which aims to confirm these two techniques for monitoring tumor vascularization. B16F10 cells were xenografted to C57BL/6 mice treated with anti-PD1 or 0.9% NaCl. Tumor volume was measured daily while CEUS and LSCI were performed weekly. LSCI and CEUS analyses showed a decrease in tumor perfusion in both groups of mice. Although both CEUS and LSCI are useful for measuring tumor volume, LSCI appears to be more robust and effective for monitoring tumor microcirculation. Non-invasive investigations are needed to better predict tumor vascularization: CEUS and LSCI have a good applicability in a mice model.


Assuntos
Melanoma , Camundongos , Animais , Velocidade do Fluxo Sanguíneo , Melanoma/diagnóstico por imagem , Camundongos Endogâmicos C57BL , Ultrassonografia , Lasers , Fluxometria por Laser-Doppler , Microcirculação , Fluxo Sanguíneo Regional
17.
J Am Heart Assoc ; 13(4): e031270, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38362899

RESUMO

BACKGROUND: Resting coronary flow velocity (CFV) in the mid-distal left anterior descending coronary artery can be easily assessed with transthoracic echocardiography. In this observational study, the authors sought to assess the relationship between resting CFV, CFV reserve (CFVR), and outcome in patients with chronic coronary syndromes. METHODS AND RESULTS: In a prospective multicenter study design, the authors retrospectively analyzed 7576 patients (age, 66±11 years; 4312 men) with chronic coronary syndromes and left ventricular ejection fraction ≥50% referred for dipyridamole stress echocardiography. Recruitment (years 2003-2021) involved 7 accredited laboratories, with interobserver variability <10% for CFV measurement at study entry. Baseline peak diastolic CFV was obtained by pulsed-wave Doppler in the mid-distal left anterior descending coronary artery. CFVR (abnormal value ≤2.0) was assessed with dipyridamole. All-cause death was the only end point. The mean CFV of the left anterior descending coronary artery was 31±12 cm/s. The mean CFVR was 2.32±0.60. During a median follow-up of 5.9±4.3 years, 1121 (15%) patients died. At multivariable analysis, resting CFV ≥32 cm/s was identified by a receiver operating curve as the best cutoff and was independently associated with mortality (hazard ratio [HR], 1.24 [95% CI, 1.10-1.40]; P<0.0001) together with CFVR ≤2.0 (HR, 1.78 [95% CI, 1.57-2.02]; P<0.0001), age, diabetes, history of coronary surgery, and left ventricular ejection fraction. When both CFV and CFVR were considered, the mortality rate was highest in patients with resting CFV ≥32 cm/s and CFVR ≤2.0 and lowest in patients with resting CFV <32 cm/s and CFVR >2.0. CONCLUSIONS: High resting CFV is associated with worse survival in patients with chronic coronary syndromes and left ventricular ejection fraction ≥50%. The value is independent and additive to CFVR. The combination of high resting CFV and low CFVR is associated with the worst survival.


Assuntos
Vasos Coronários , Função Ventricular Esquerda , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Estudos Retrospectivos , Volume Sistólico , Vasos Coronários/diagnóstico por imagem , Dipiridamol , Circulação Coronária , Ecocardiografia sob Estresse/métodos , Velocidade do Fluxo Sanguíneo
18.
BMC Pregnancy Childbirth ; 24(1): 60, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38216901

RESUMO

BACKGROUND: Present evidence suggests that the Doppler ultrasonographic indices, such as carotid artery blood flow (CABF) and velocity time integral (VTI), had the ability to predict fluid responsiveness in non-obstetric patients. The purpose of this study was to assess their capacity to predict fluid responsiveness in spontaneous breathing parturients undergoing caesarean section and to determine the effect of detecting and management of hypovolemia (fluid responsiveness) on the incidence of hypotension after anaesthesia. METHODS: A total of 72 full term singleton parturients undergoing elective caesarean section were enrolled in this study. CABF, VTI, and hemodynamic parameters were recorded before and after fluid challenge and assessed by carotid artery ultrasonography. Fluid responsiveness was defined as an increase in stroke volume index (SVI) of 15% or more after the fluid challenge. RESULTS: Thirty-one (43%) patients were fluid responders. The area under the ROC curve to predict fluid responsiveness for CABF and VTI were 0.803 (95% CI, 0.701-0.905) and 0.821 (95% CI, 0.720-0.922). The optimal cut-off values of CABF and VTI for fluid responsiveness was 175.9 ml/min (sensitivity of 74.0%; specificity of 78.0%) and 8.7 cm/s (sensitivity of 67.0%; specificity of 90.0%). The grey zone for CABF and VTI were 114.2-175.9 ml/min and 6.8-8.7 cm/s. The incidence of hypotension after the combined spinal-epidural anaesthesia (CSEA) was significantly higher in the Responders group 25.8% (8/31) than in the Non-Responders group 17.1(7/41) (P < 0.001). The total incidence of hypotension after CSEA of the two groups was 20.8% (15/72). CONCLUSIONS: Ultrasound evaluation of CABF and VTI seem to be the feasible parameters to predict fluid responsiveness in parturients undergoing elective caesarean section and detecting and management of hypovolemia (fluid responsiveness) could significantly decrease incidence of hypotension after anaesthesia. TRIAL REGISTRATION: The trial was registered at the Chinese Clinical Trial Registry (ChiCTR) ( www.chictr.org ), registration number was ChiCTR1900022327 (The website link: https://www.chictr.org.cn/showproj.html?proj=37271 ) and the date of trial registration was in April 5, 2019. This study was performed in accordance with the Declaration of Helsinki and approved by the Research Ethics Committee of Women's Hospital, Zhejiang University School of Medicine (20,180,120).


Assuntos
Cesárea , Hipotensão , Humanos , Feminino , Gravidez , Cesárea/efeitos adversos , Hipovolemia/etiologia , Estudos Prospectivos , Hemodinâmica/fisiologia , Artérias Carótidas/diagnóstico por imagem , Hipotensão/etiologia , Ultrassonografia das Artérias Carótidas , Hidratação , Velocidade do Fluxo Sanguíneo/fisiologia
19.
Photodiagnosis Photodyn Ther ; 45: 103985, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38246214

RESUMO

BACKGROUND: To evaluate the choroidal thickness and retrobulbar hemodynamic parameters in polycythemia vera (PV) patients in comparison with healthy individuals, and to investigate the relationship of these values with blood hematocrit levels. METHODS: This prospective study included the 35 eyes of 35 PV patients and the 30 eyes of 30 healthy individuals. Choroidal thickness was measured at the subfoveal area and at 500 µm intervals nasal and temporal to the fovea up to a distance of 1500 µm. Color Doppler ultrasonography (CDU) was used to evaluate the retrobulbar vessels. Complete blood count values were recorded. RESULTS: Choroidal thickness was found to be significantly lower in the PV group than in the control group at the subfoveal, nasal 500, and temporal 500 and 1000 µm measurement points (p = 0.01, p = 0.011, p = 0.04, p = 0.045, respectively). The central retinal artery (CRA) peak systolic velocity (PSV) and end diastolic velocity (EDV) values and the ophthalmic artery (OA) PSV value were significantly lower in the PV group than in the control group (p < 0.001, p < 0.001, p = 0.019, respectively). No significant difference was present between the groups in terms of CRA and OA resistive index (RI) and pulsatile index (PI) values (p = 0.388, p = 0.564, p = 0.897, p = 0.693, respectively). A negative correlation was found between the blood hematocrit levels and the subfoveal, nasal 500 µm, and temporal 500 µm choroidal thickness measurements and the CRA PSV and EDV and the OA PSV values. CONCLUSIONS: PV may cause microvascular changes and lead to ocular vascular complications by affecting the choroidal and retrobulbar blood flow.


Assuntos
Fotoquimioterapia , Policitemia Vera , Humanos , Estudos Prospectivos , Velocidade do Fluxo Sanguíneo/fisiologia , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Hemodinâmica , Corioide/diagnóstico por imagem
20.
Acta Obstet Gynecol Scand ; 103(4): 660-668, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38226422

RESUMO

INTRODUCTION: Chemotherapy during pregnancy can increase the risk of fetal anemia. Severe fetal anemia can lead to the development of hydrops fetalis and potentially fetal demise. Hence, it is imperative to implement consistent monitoring methods in the context of chemotherapy treatment. This study aimed to diagnose and monitor fetal anemia using middle cerebral artery peak systolic velocity (MCA-PSV) as a diagnostic tool during chemotherapy in pregnant women. MATERIAL AND METHODS: The study employed a prospective analysis involving a case series of 15 patients diagnosed with cancer during pregnancy and subsequently underwent chemotherapy. MCA-PSV was used to identify fetal anemia. The patients were scheduled for ultrasound examinations of the MCA-PSV. The first examination was performed on the same day as the administration of chemotherapy, while the second occurred on the 10th day after chemotherapy. The measurement technique used in the study was based on the methodology proposed by Mari and Barr. The multiples of the median were calculated using the calculators provided by Medicina Fetal Barcelona. Based on these values anemia severity was determined. When moderate or severe anemia was identified, chemotherapy was individually modified. Additionally, a blood count analysis was conducted immediately after the delivery of the newborn. RESULTS: Five patients were diagnosed with fetal or newborn anemia. With MCA-PSV, we identified moderate fetal anemia in two patients and severe fetal anemia in one. The complete blood count testing of newborns revealed mild anemia in three patients. One case was unrelated to chemotherapy-induced anemia. During treatment, fetal anemia did not corelate with maternal anemia. CONCLUSIONS: In four cases of anemia the combination of cisplatin and iphosphamide was used as a chemotherapy agent. No anemia was observed in other drug combinations. Our findings suggest that MCA-PSV is a reliable method for identifying anemia and should be included in the treatment protocol for chemotherapy-induced fetal anemia.


Assuntos
Anemia , Antineoplásicos , Doenças Fetais , Humanos , Feminino , Recém-Nascido , Gravidez , Artéria Cerebral Média/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Ultrassonografia Pré-Natal , Anemia/induzido quimicamente , Anemia/diagnóstico , Doenças Fetais/induzido quimicamente , Doenças Fetais/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA