Systemic and local inflammatory response after implantation of biomaterial in critical bone injuries
Acta cir. bras
; 38: e383823, 2023. tab, graf
Article
en En
|
LILACS-Express
| LILACS, VETINDEX
| ID: biblio-1513539
Biblioteca responsable:
BR1.1
ABSTRACT
ABSTRACT Purpose:
To evaluate inflammatory response in critical bone injuries after implantation of the biomaterial composed of hydroxyapatite (HA)/poly (lactic-coglycolic acid) (PLGA)/BLEED.Methods:
Forty-eight male Wistar rats (280 ± 20 grams) were divided into two groups control group (CG), in which the animals do not receive any type of treatment; and biomaterial group (BG), in which the animals received the HA/PLGA/BLEED scaffold. Critical bone injury was induced in the medial region of the skull calotte with the aid of a trephine drill 8 mm in diameter. The biomaterial was implanted in the form of 1.5-mm thick scaffolds. Serum and calotte were collected at one, three and seven days.Results:
Biomaterial had a significant effect on the morphological structure of the bone, accelerating osteoblast activation within three days, without causing exacerbated systemic inflammation. In addition, quantitative real-time polymerase chain reaction (qRT-PCR) analysis showed that BG induced upregulation of osteogenic genes such as runt-related transcription factor 2, and stimulated genes of inflammatory pathways such as tumor necrosis factor-α, on the first day without overexpressing genes related to bone matrix degradation, such as tissue inhibitor of metalloproteinases-1 and matrix metalloproteinase-9.Conclusions:
The HA/PLGA/BLEED® association can be used as a bone graft to aid bone repair, as it is capable of modulating expression of important genes at this stage of the repair process.
Texto completo:
1
Idioma:
En
Revista:
Acta cir. bras
Año:
2023
Tipo del documento:
Article
/
Project document