Your browser doesn't support javascript.
loading
Theoretical and experimental determination of dosimetric characteristics for ADVANTAGE Pd-103 brachytherapy source.
Meigooni, Ali S; Dini, Sharifeh A; Awan, Shahid B; Dou, Kai; Koona, Rafiq A.
Afiliación
  • Meigooni AS; Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536, USA. alimeig@uky.edu
Appl Radiat Isot ; 64(8): 881-7, 2006 Aug.
Article en En | MEDLINE | ID: mdl-16713277
ADVANTAGE Pd-103 brachytherapy source has been recently introduced by IsoAid for prostate permanent implants. Dosimetric characteristics (Dose rate constant, radial dose function, 2D-, and 1D-anisotropy functions) of this source model have been determined using both theoretical and experimental methods, following the updated TG-43U1 protocol. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with the 1999 Standards. Measurements were performed in Solid Water using LiF TLD chips and the theoretical calculations were performed in Solid Water and liquid water phantom materials using PTRAN Monte Carlo code. The results of the Monte Carlo simulation have shown a dose rate constant of 0.69 cGyh(-1) U(-1) in liquid water and 0.67 cGyh(-1) U(-1) in Solid Water medium. The measured dose rate constant in Solid Water was found to be 0.68+/-8% cGyh(-1) U(-1), which is in a good agreement (within +/-5%) to the Monte Carlo simulated data. The 2D- and 1D-anisotropy functions of the ADVANTAGE Pd-103 source were calculated for radial distances ranging from 0.5 to 5.0 cm. Radial dose function was determined for radial distances ranging from 0.2 to 8.0 cm using line source approximation. All these calculations are based on L(eff) equal to 3.61 cm, calculated following TG-43U1 recommendations. The tabulated data for 2D-anisotropy function, 1D-anisotropy function, dose rate constant and radial dose function have been produced for clinical application of this source model.
Asunto(s)
Buscar en Google
Colección: 01-internacional Asunto principal: Paladio / Radiometría / Planificación de la Radioterapia Asistida por Computador / Braquiterapia / Modelos Biológicos Tipo de estudio: Guideline Límite: Humans País/Región como asunto: America do norte Idioma: En Revista: Appl radiat isot Asunto de la revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Año: 2006 Tipo del documento: Article País de afiliación: Estados Unidos
Buscar en Google
Colección: 01-internacional Asunto principal: Paladio / Radiometría / Planificación de la Radioterapia Asistida por Computador / Braquiterapia / Modelos Biológicos Tipo de estudio: Guideline Límite: Humans País/Región como asunto: America do norte Idioma: En Revista: Appl radiat isot Asunto de la revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Año: 2006 Tipo del documento: Article País de afiliación: Estados Unidos