Dose imaging in a thorax phantom with lung-equivalent volume at the epithermal neutron beam of LVR-15 reactor.
Appl Radiat Isot
; 67(7-8 Suppl): S214-7, 2009 Jul.
Article
en En
| MEDLINE
| ID: mdl-19376722
ABSTRACT
A thorax phantom has been designed, consisting of PMMA and PE plates containing a cavity filled with a laboratory-made lung-substitute. Fricke-gel dosimeters have been placed in the lung-substitute volume, and the phantom has been irradiated at the epithermal column of LVR-15 reactor. Absorbed dose images have been obtained for both gamma radiation and charged particles emitted in the (10)B reactions with thermal neutrons. Measurements with thermoluminescence dosimeters (TLDs) and Monte Carlo (MC) calculations have been performed too, in order to attain inter-comparison of results.