Your browser doesn't support javascript.
loading
Gas chromatography-tandem mass spectrometry assay for the quantification of four benzodiazepines and citalopram in eleven postmortem rabbit fluids and tissues, with application to animal and human samples.
Cartiser, N; Bévalot, F; Le Meur, C; Gaillard, Y; Malicier, D; Hubert, N; Guitton, J.
Afiliación
  • Cartiser N; Laboratoire de Toxicologie, ISPB-Faculté de Pharmacie, Université de Lyon, Université Claude Bernard Lyon 1, 8 Avenue Rockefeller, 69373 Lyon Cedex 08, France.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(27): 2909-18, 2011 Oct 01.
Article en En | MEDLINE | ID: mdl-21907645
ABSTRACT
Pharmacokinetic studies and postmortem toxicological investigations require a validated analytical technique to quantify drugs on a large number of matrices. Three-step liquid/liquid extraction with online derivatization (silylation) ahead of analysis by gas chromatography-tandem mass spectrometry was developed and validated on rabbit specimens in order to quantify citalopram and 4 benzodiazepines (diazepam, nordazepam, oxazepam and temazepam) in 11 biological matrices (blood, urine, bile, vitreous humor, liver, kidney, skeletal muscle, brain, adipose tissue, bone marrow (BM) and lung). Since the 11 biological matrices came from the same animal species, full validation was performed on 1 matrix, bone marrow (considered the most complex), while the other 10 underwent partial validation. Due to non-negligible matrix effects, calibration curves were performed on each matrix. Within-day and between-day precision (less than 12.0% and 12.6%, respectively) and accuracy (from 88.9% to 106.4%) were acceptable on BM at both low and high concentrations. Assessment on the other matrices confirmed accuracy and within-day precision (less than 12%, and generally between 85.1% and 114.5%, respectively). The lower limit of quantification of the method was 1ng/g for nordazepam, 5ng/g for citalopram and 10ng/g for oxazepam, diazepam and temazepam. The combination of 3-step extraction and MS/MS detection provided good selectivity in all matrices, including the most lipid-rich. Application to real-case samples showed that the method was sensitive enough to describe distribution patterns in an animal experiment, and specific enough to detect molecules in highly putrefied samples from human postmortem cases.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Asunto principal: Benzodiazepinonas / Líquidos Corporales / Citalopram / Espectrometría de Masas en Tándem / Cromatografía de Gases y Espectrometría de Masas Tipo de estudio: Diagnostic_studies Límite: Animals / Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2011 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Asunto principal: Benzodiazepinonas / Líquidos Corporales / Citalopram / Espectrometría de Masas en Tándem / Cromatografía de Gases y Espectrometría de Masas Tipo de estudio: Diagnostic_studies Límite: Animals / Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2011 Tipo del documento: Article País de afiliación: Francia