Your browser doesn't support javascript.
loading
Liver Selective Internal Radiation Therapy with (90)Y resin microspheres: comparison between pre-treatment activity calculation methods.
Bernardini, M; Smadja, C; Faraggi, M; Orio, S; Petitguillaume, A; Desbrée, A; Ghazzar, N.
Afiliación
  • Bernardini M; Nuclear Medicine Department, Hôpital Européen Georges Pompidou (HEGP), Paris, France. Electronic address: michela.bernardini@egp.aphp.fr.
  • Smadja C; Nuclear Medicine Department, Hôpital Européen Georges Pompidou (HEGP), Paris, France.
  • Faraggi M; Nuclear Medicine Department, Centre Hospitalier Princesse Grace, Monaco.
  • Orio S; Nuclear Medicine Department, Hôpital Européen Georges Pompidou (HEGP), Paris, France.
  • Petitguillaume A; Laboratoire d'Evaluation de la Dose Interne (LEDI), Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Fontenay-Aux-Roses, France.
  • Desbrée A; Laboratoire d'Evaluation de la Dose Interne (LEDI), Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Fontenay-Aux-Roses, France.
  • Ghazzar N; Nuclear Medicine Department, Hôpital Européen Georges Pompidou (HEGP), Paris, France.
Phys Med ; 30(7): 752-64, 2014 Nov.
Article en En | MEDLINE | ID: mdl-24923844
ABSTRACT
Different methods to calculate (90)Y resin microspheres activity for Selective Internal Radiation Therapy (SIRT) were compared. Such comparison is not yet available and is needed in clinical practice to optimize patient specific treatment planning. 32 (99m)Tc-macroagregates (MAA) evaluations were performed, followed by 26 treatments. Four methods to calculate (90)Y-activity were applied retrospectively three based on Body Surface Area and one based on MIRD formalism, partition model (PM). Relationships between calculated activities, lung breakthrough (LB), the activity concentration ratio between lesions and healthy liver (T/N) and tumour involvement were investigated, where lobar and whole liver treatments were analysed separately. Without attenuation correction, overestimation of LB was 65%. In any case, the estimated lungs' doses remained below 30 Gy. Thus, the maximal injectable activity (MIA) is not limited by lungs' irradiation. Moreover, LB was not significantly related to T/N, neither to tumour involvement nor radiochemical purity (RP). Differences in calculated activity with the four methods were extremely large, in particular they were greater between BSA-based and PM activities for lobar treatments (from -85% to 417%) compared to whole liver treatments (from -49% to 61%). Two values of T/N ratio were identified as thresholds for BSA-based methods, healthy liver doses are much higher than 30 Gy when T/N < 3; for PM, tumour doses are higher than 120 Gy when T/N > 4. As PM accounts for uptake ratio between normal and tumour liver, this method should be employed over BSA-based methods.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Asunto principal: Planificación de la Radioterapia Asistida por Computador / Hígado / Microesferas Límite: Humans Idioma: En Revista: Phys Med Asunto de la revista: BIOFISICA / BIOLOGIA / MEDICINA Año: 2014 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Asunto principal: Planificación de la Radioterapia Asistida por Computador / Hígado / Microesferas Límite: Humans Idioma: En Revista: Phys Med Asunto de la revista: BIOFISICA / BIOLOGIA / MEDICINA Año: 2014 Tipo del documento: Article