Your browser doesn't support javascript.
loading
Long-term Local and Systemic Safety of Poly(L-lactide-co-epsilon-caprolactone) after Subcutaneous and Intra-articular Implantation in Rats.
Ramot, Yuval; Nyska, Abraham; Markovitz, Elana; Dekel, Assaf; Klaiman, Guy; Zada, Moran Haim; Domb, Abraham J; Maronpot, Robert R.
Afiliación
  • Ramot Y; Hadassah-Hebrew University Medical Center, Jerusalem, Israel.
  • Nyska A; Tel Aviv University and Consultant in Toxicologic Pathology, Timrat, Israel anyska@bezeqint.net.
  • Markovitz E; Ortho-Space Ltd., Caesarea, Israel.
  • Dekel A; Ortho-Space Ltd., Caesarea, Israel.
  • Klaiman G; Harlan Biotech Israel Ltd., Rehovot, Israel.
  • Zada MH; Institute for Drug Research, School of Pharmacy, Faculty of Medicine, The Hebrew University of Jerusalem, Ein Kerem, Jerusalem, Israel.
  • Domb AJ; Institute for Drug Research, School of Pharmacy, Faculty of Medicine, The Hebrew University of Jerusalem, Ein Kerem, Jerusalem, Israel.
  • Maronpot RR; Maronpot Consulting LLC, Raleigh, North Carolina, USA.
Toxicol Pathol ; 43(8): 1127-40, 2015 Dec.
Article en En | MEDLINE | ID: mdl-26296630
ABSTRACT
The use of biodegradable materials is gaining popularity in medicine, especially in orthopedic applications. However, preclinical evaluation of biodegradable materials can be challenging, since they are located in close contact with host tissues and might be implanted for a long period of time. Evaluation of these compounds requires biodegradability and biocompatibility studies and meticulous pathology examination. We describe 2 preclinical studies performed on Sprague-Dawley rats for 52 weeks, to evaluate clinical pathology, biocompatibility, biodegradability, and systemic toxicity after implantation of 2-layered films or saline-inflated balloon-shaped implants of downsized InSpace™ devices (termed "test device"). The test devices are made from a copolymer of poly-L-lactide-co-∊-caprolactone in a 7030 ratio, identical to the device used in humans, intended for the treatment of rotator cuff tears. Intra-articular film implantation and subcutaneous implantation of the downsized device showed favorable local and systemic tolerability. Although the implanted materials have no inherent toxic or tumorigenic properties, one animal developed a fibrosarcoma at the implantation site, an event that is associated with a rodent-predilection response where solid materials cause mesenchymal neoplasms. This effect is discussed in the context of biodegradable materials along with a detailed description of expected pathology for biodegradable materials in long-term rodent studies.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Asunto principal: Poliésteres / Prótesis e Implantes / Materiales Biocompatibles / Manguito de los Rotadores / Tejido Subcutáneo Límite: Animals Idioma: En Revista: Toxicol Pathol Año: 2015 Tipo del documento: Article País de afiliación: Israel

Texto completo: 1 Colección: 01-internacional Asunto principal: Poliésteres / Prótesis e Implantes / Materiales Biocompatibles / Manguito de los Rotadores / Tejido Subcutáneo Límite: Animals Idioma: En Revista: Toxicol Pathol Año: 2015 Tipo del documento: Article País de afiliación: Israel