Homemade Hypertonic Saline: Essential Treatment Can Be Available and Affordable.
Elior, Nili; Tasher, Diana; Somekh, Elli; Stein, Michal; Schwartz Harari, Orna; Mandelberg, Avigdor.
Afiliación
  • Elior N; Pediatric Infectious Disease Unit, Wolfson Medical Center, Holon, Israel.
  • Tasher D; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Somekh E; Pediatric Infectious Disease Unit, Wolfson Medical Center, Holon, Israel.
  • Stein M; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Schwartz Harari O; Pediatric Infectious Disease Unit, Wolfson Medical Center, Holon, Israel.
  • Mandelberg A; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
Isr Med Assoc J ; 19(12): 741-746, 2017 Dec.
Article en En | MEDLINE | ID: mdl-29235735
ABSTRACT

BACKGROUND:

Nebulized hypertonic saline (HS) treatment is unavailable to large populations worldwide.

OBJECTIVES:

To determine the bacterial contamination and electrolyte concentrations in homemade (HM-HS) vs. pharmacy made (PM-HS).

METHODS:

We conducted three double-blind consecutive trials 50 boiled-water homemade 3%-HS (B-HM-HS) bottles and 50 PM-HS. The bottles were cultured after 48 hours. Electrolyte concentrations were measured in 10 bottles (5 per group). Forty bottles (20 per group) were distributed to volunteers for simulation of realistic treatment by drawing 4 ml HS three times daily. From each bottle, 4 ml samples were cultured after 1, 5, and 7 days. Volunteers prepared 108 bottles containing 3%-HS, sterilizing them using a microwave oven (1100-1850W). These bottles were cultured 24 hours, 48 hours, and 1 month after preparation.

RESULTS:

Contamination rates of B-HM-HS and PM-HS after 48 hours were 56% and 14%, respectively (P = 0.008). Electrolyte concentrations were similar 3.7% ± 0.4 and 3.5% ± 0.3, respectively (P = NS). Following a single day of simulation B-HM-HS bottles were significantly more contaminated than PM-HS bottles 75% vs. 20%, respectively (P < 0.01). By day 7, 85% of PM-HS bottles and 100% of B-HM-HS bottles were contaminated (P = 0.23). All 108 microwave-oven prepared bottles (MICRO-HS) were sterile, which was significantly better than the contamination rate of B-HM-HS and PM-HS (P < 0.001). Calculated risk for a consecutive MICRO-HS to be infected was negligible.

CONCLUSIONS:

Microwave preparation provides sterile HS with adequate electrolyte concentrations, and is a cheap, fast, and widely available method to prepare HS.
Asunto(s)
Buscar en Google
Colección: 01-internacional Asunto principal: Terapia Respiratoria / Solución Salina Hipertónica / Infecciones Bacterianas / Enfermedades Bronquiales / Esterilización / Contaminación de Medicamentos / Composición de Medicamentos Tipo de estudio: Clinical_trials / Etiology_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Isr Med Assoc J Asunto de la revista: MEDICINA Año: 2017 Tipo del documento: Article País de afiliación: Israel
Buscar en Google
Colección: 01-internacional Asunto principal: Terapia Respiratoria / Solución Salina Hipertónica / Infecciones Bacterianas / Enfermedades Bronquiales / Esterilización / Contaminación de Medicamentos / Composición de Medicamentos Tipo de estudio: Clinical_trials / Etiology_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Isr Med Assoc J Asunto de la revista: MEDICINA Año: 2017 Tipo del documento: Article País de afiliación: Israel